From 6100372a9eb89aff489c98bf5a832959482522dc Mon Sep 17 00:00:00 2001 From: Viktor Barzin Date: Sat, 22 Mar 2025 15:47:16 +0000 Subject: [PATCH] adjust batter low alert to fire only when there is no pwoer [ci skip] --- modules/kubernetes/monitoring/prometheus_chart_values.tpl | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/modules/kubernetes/monitoring/prometheus_chart_values.tpl b/modules/kubernetes/monitoring/prometheus_chart_values.tpl index b6d437d1..eb2ab8fc 100644 --- a/modules/kubernetes/monitoring/prometheus_chart_values.tpl +++ b/modules/kubernetes/monitoring/prometheus_chart_values.tpl @@ -173,7 +173,7 @@ serverFiles: annotations: summary: "UPS on battery for {{ $value }} seconds" - alert: LowUPBattery - expr: ups_upsEstimatedMinutesRemaining < 25 + expr: ups_upsEstimatedMinutesRemaining < 25 and on(instance) ups_upsInputVoltage < 150 for: 1m labels: severity: critical