fan-control: simplify HA dashboard + Lock = freeze-current/algo-off [ci skip]
The dashboard-it Server → Fans view is now minimal: fan speed (% + RPM), an Override % slider, and a Lock toggle. Lock now means "freeze the current speed, algorithm off" — a new automation (r730_fan_lock_freeze_current_speed_resume_algo) snapshots the live target % into Override and sets mode=manual on lock-ON, and mode=auto on lock-OFF. The host daemon is unchanged (the toggle just drives the mode it already reads). cool/quiet stay reachable via the entity but are off the simplified view; the 60-min auto-revert is kept as a dormant safety net. Verified live: lock ON → mode=manual + Override captured the live 60%; lock OFF → auto. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
This commit is contained in:
parent
f9376a36ff
commit
c059405632
2 changed files with 30 additions and 23 deletions
|
|
@ -132,12 +132,15 @@ Delivered ahead of the cron migration (which is Vault-gated) by teaching the
|
|||
`input_select.r730_fan_mode` (auto/cool/quiet/manual) +
|
||||
`input_number.r730_fan_manual_pct`. `auto` = the garage-presence curve above;
|
||||
cool/quiet force that curve; manual holds a fixed %; `CEILING` still overrides.
|
||||
HA owns the setpoint + a 60-min auto-revert-to-auto automation
|
||||
(`automation.r730_fan_mode_auto_revert`), which an `input_boolean.r730_fan_lock`
|
||||
toggle can disable so a deliberate override persists (a "🔒 LOCKED" banner shows
|
||||
on the view while engaged; the ceiling still wins, and the automation re-checks
|
||||
the lock after the delay so locking mid-countdown cancels the revert) — the
|
||||
daemon just polls and actuates.
|
||||
The **simplified dashboard (2026-06-05)** exposes just three things — fan speed
|
||||
(%/RPM), an **Override %** slider, and a **Lock** toggle. Lock = "freeze current
|
||||
speed / algo off": `automation.r730_fan_lock_freeze_current_speed_resume_algo`
|
||||
snapshots the live target % into Override and sets `mode=manual` on lock-ON, and
|
||||
`mode=auto` on lock-OFF — the daemon needs no change, the toggle just drives the
|
||||
mode. `cool`/`quiet` stay reachable via the entity but are off the dashboard. The
|
||||
60-min `automation.r730_fan_mode_auto_revert` is retained as a dormant safety net
|
||||
(manual now only happens while locked, which it skips). The daemon just polls and
|
||||
actuates.
|
||||
Monitoring + control live on the dashboard-it "Server" view (REST sensors: fan
|
||||
RPM from the redfish exporter; mode/target-% from the Pushgateway). The same
|
||||
logic already exists in the Python controller (`r730-fan-control/`) for the
|
||||
|
|
|
|||