monitoring: drop PVAutoExpanding alert — info-only noise, not actionable
PVAutoExpanding fired at >80% used (info severity), but pvc-autoresizer's threshold is 10% free (= 90% used) — the alert always fired ~10 points before any action would have been taken, and there was nothing for an operator to do during that window either. It was a "heads up" that didn't surface a problem. Real failure modes are already covered: * PVFillingUp (critical, >95% for 10m) — autoresizer didn't keep up * PVPredictedFull (warning, predict_linear 24h) — trend toward exhaustion Sharpened PVFillingUp's annotation to spell out the likely causes (storage_limit reached, expansion failing, or missing autoresizer annotations) so the responder doesn't have to recall the runbook.
This commit is contained in:
parent
396cce82cf
commit
cd13b9d062
1 changed files with 6 additions and 8 deletions
|
|
@ -1134,20 +1134,18 @@ serverFiles:
|
|||
severity: warning
|
||||
annotations:
|
||||
summary: "Disk {{ $labels.mountpoint }} on {{ $labels.instance }}: {{ $value | printf \"%.1f\" }}% free (threshold: 10%)"
|
||||
- alert: PVAutoExpanding
|
||||
expr: (kubelet_volume_stats_used_bytes / kubelet_volume_stats_capacity_bytes) * 100 > 80 and kubelet_volume_stats_capacity_bytes < 1099511627776
|
||||
for: 5m
|
||||
labels:
|
||||
severity: info
|
||||
annotations:
|
||||
summary: "PV {{ $labels.persistentvolumeclaim }} in {{ $labels.namespace }}: {{ $value | printf \"%.0f\" }}% used — auto-expansion should trigger"
|
||||
# PVAutoExpanding removed — was info-only at >80% used, but
|
||||
# pvc-autoresizer's threshold is 10% free (= 90% used), so the
|
||||
# alert always fired ~10 percentage points before any action
|
||||
# was needed. Real failures are caught by PVFillingUp (autoresizer
|
||||
# didn't keep up) and PVPredictedFull (trend toward exhaustion).
|
||||
- alert: PVFillingUp
|
||||
expr: (kubelet_volume_stats_used_bytes / kubelet_volume_stats_capacity_bytes) * 100 > 95 and kubelet_volume_stats_capacity_bytes < 1099511627776
|
||||
for: 10m
|
||||
labels:
|
||||
severity: critical
|
||||
annotations:
|
||||
summary: "PV {{ $labels.persistentvolumeclaim }} in {{ $labels.namespace }}: {{ $value | printf \"%.0f\" }}% used — auto-expansion may have failed"
|
||||
summary: "PV {{ $labels.persistentvolumeclaim }} in {{ $labels.namespace }}: {{ $value | printf \"%.0f\" }}% used — pvc-autoresizer didn't expand in time (storage_limit reached, expansion failing, or no autoresizer annotations)"
|
||||
- alert: PVPredictedFull
|
||||
expr: predict_linear(kubelet_volume_stats_used_bytes[6h], 3600*24) > kubelet_volume_stats_capacity_bytes and kubelet_volume_stats_capacity_bytes < 1099511627776
|
||||