# config: # scrape_configs: # - job_name: 'idrac-snmp' # static_configs: # - targets: # - idrac.viktorbarzin.lan # # metrics_path: /snmp # params: # module: [dell_idrac] # relabel_configs: # - source_labels: [__address__] # target_label: __param_target # - source_labels: [__param_target] # target_label: instance # - target_label: __address__ # replacement: idrac.viktorbarzin.lan:161 # The SNMP exporter's Service name and port. # service: # port: 9102 podAnnotations: prometheus.io/scrape: "true" prometheus.io/path: "/snmp?target=idrac.viktorbarzin.lan%3A161&module=dell_idrac" prometheus.io/port: "9116" # config: | # dell_idrac: # walk: # - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20 # - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 # - 1.3.6.1.4.1.674.10892.5.2.1 # - 1.3.6.1.4.1.674.10892.5.2.3 # - 1.3.6.1.4.1.674.10892.5.2.4 # - 1.3.6.1.4.1.674.10892.2.4.1.1.13 # metrics: # #OID for your raid components status # - name: idrac_virtualDiskComponentStatus # oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20 # type: gauge # help: The status of the virtual disk itself without the propagation of any contained # component status - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20 # indexes: # - labelname: virtualDiskNumber # type: gauge # #OID for your physical disk status # - name: idrac_physicalDiskComponentStatus # oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 # type: gauge # help: The status of the physical disk itself without the propagation of any contained # component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 # indexes: # - labelname: physicalDiskNumber # type: gauge # #Global System Health # - name: idrac_globalSystemStatus # oid: 1.3.6.1.4.1.674.10892.5.2.1 # type: gauge # help: This attribute defines the overall rollup status of all components in the # system being monitored by the remote access card - 1.3.6.1.4.1.674.10892.5.2.1 # #Global Storage Health # - name: idrac_globalStorageStatus # oid: 1.3.6.1.4.1.674.10892.5.2.3 # type: gauge # help: This attribute defines the overall storage status being monitored by the # remote access card. - 1.3.6.1.4.1.674.10892.5.2.3 # #Global Power System Health # - name: idrac_systemPowerState # oid: 1.3.6.1.4.1.674.10892.5.2.4 # type: gauge # help: This attribute defines the power state of the system. - 1.3.6.1.4.1.674.10892.5.2.4 # # Power consumption in Watts # - name: idrac_drsWattsReading # oid: 1.3.6.1.4.1.674.10892.2.4.1.1.13 # type: gauge # help: Defines the instantaneous chassis power usage (in watts). # indexes: # - labelname: drsWattsReading # WARNING: This file was auto-generated using snmp_exporter generator, manual changes will be lost. config: | dell_idrac: walk: - 1.3.6.1.4.1.674.10892.5.2 - 1.3.6.1.4.1.674.10892.5.4.1100.30 - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14 - 1.3.6.1.4.1.674.10892.5.4.200 - 1.3.6.1.4.1.674.10892.5.4.600.12.1 - 1.3.6.1.4.1.674.10892.5.4.600.30.1.6 - 1.3.6.1.4.1.674.10892.5.4.700.20.1 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 get: - 1.3.6.1.2.1.1.3.0 - 1.3.6.1.4.1.674.10892.5.4.300.50.1.5.1.1 metrics: - name: sysUpTime oid: 1.3.6.1.2.1.1.3 type: gauge help: The time (in hundredths of a second) since the network management portion of the system was last re-initialized. - 1.3.6.1.2.1.1.3 - name: globalSystemStatus oid: 1.3.6.1.4.1.674.10892.5.2.1 type: gauge help: This attribute defines the overall rollup status of all components in the system being monitored by the remote access card - 1.3.6.1.4.1.674.10892.5.2.1 enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemLCDStatus oid: 1.3.6.1.4.1.674.10892.5.2.2 type: gauge help: This attribute defines the system status as it is reflected by the LCD front panel - 1.3.6.1.4.1.674.10892.5.2.2 enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: globalStorageStatus oid: 1.3.6.1.4.1.674.10892.5.2.3 type: gauge help: This attribute defines the overall storage status being monitored by the remote access card. - 1.3.6.1.4.1.674.10892.5.2.3 enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemPowerState oid: 1.3.6.1.4.1.674.10892.5.2.4 type: gauge help: This attribute defines the power state of the system. - 1.3.6.1.4.1.674.10892.5.2.4 enum_values: 1: other 2: unknown 3: "off" 4: "on" - name: systemPowerUpTime oid: 1.3.6.1.4.1.674.10892.5.2.5 type: gauge help: This attribute defines the power-up time of the system in seconds. - 1.3.6.1.4.1.674.10892.5.2.5 - name: processorDevicechassisIndex oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1 type: gauge help: 1100.0030.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceIndex oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2 type: gauge help: 1100.0030.0001.0002 This attribute defines the index (one based) of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceStateCapabilities oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3 type: gauge help: 1100.0030.0001.0003 This attribute defines the state capabilities of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: unknownCapabilities 2: enableCapable 4: notReadyCapable 6: enableAndNotReadyCapable - name: processorDeviceStateSettings oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4 type: gauge help: 1100.0030.0001.0004 This attribute defines the state settings of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: unknown 2: enabled 4: notReady 6: enabledAndNotReady - name: processorDeviceStatus oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5 type: gauge help: 1100.0030.0001.0005 This attribute defines the status of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: processorDeviceType oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7 type: gauge help: 1100.0030.0001.0007 This attribute defines the type of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: deviceTypeIsOther 2: deviceTypeIsUnknown 3: deviceTypeIsCPU 4: deviceTypeIsMathProcessor 5: deviceTypeIsDSP 6: deviceTypeIsAVideoProcessor - name: processorDeviceManufacturerName oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8 type: OctetString help: 1100.0030.0001.0008 This attribute defines the name of the manufacturer of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceStatusState oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9 type: gauge help: 1100.0030.0001.0009 This attribute defines the status state of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: other 2: unknown 3: enabled 4: userDisabled 5: biosDisabled 6: idle - name: processorDeviceFamily oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10 type: gauge help: 1100.0030.0001.0010 This attribute defines the family of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: deviceFamilyIsOther 2: deviceFamilyIsUnknown 3: deviceFamilyIs8086 4: deviceFamilyIs80286 5: deviceFamilyIsIntel386 6: deviceFamilyIsIntel486 7: deviceFamilyIs8087 8: deviceFamilyIs80287 9: deviceFamilyIs80387 10: deviceFamilyIs80487 11: deviceFamilyIsPentium 12: deviceFamilyIsPentiumPro 13: deviceFamilyIsPentiumII 14: deviceFamilyIsPentiumMMX 15: deviceFamilyIsCeleron 16: deviceFamilyIsPentiumIIXeon 17: deviceFamilyIsPentiumIII 18: deviceFamilyIsPentiumIIIXeon 19: deviceFamilyIsPentiumIIISpeedStep 20: deviceFamilyIsItanium 21: deviceFamilyIsIntelXeon 22: deviceFamilyIsPentium4 23: deviceFamilyIsIntelXeonMP 24: deviceFamilyIsIntelItanium2 25: deviceFamilyIsK5 26: deviceFamilyIsK6 27: deviceFamilyIsK6Dash2 28: deviceFamilyIsK6Dash3 29: deviceFamilyIsAMDAthlon 30: deviceFamilyIsAMD2900 31: deviceFamilyIsK6Dash2Plus 32: deviceFamilyIsPowerPC 33: deviceFamilyIsPowerPC601 34: deviceFamilyIsPowerPC603 35: deviceFamilyIsPowerPC603Plus 36: deviceFamilyIsPowerPC604 37: deviceFamilyIsPowerPC620 38: deviceFamilyIsPowerPCx704 39: deviceFamilyIsPowerPC750 40: deviceFamilyIsIntelCoreDuo 41: deviceFamilyIsIntelCoreDuoMobile 42: deviceFamilyIsIntelCoreSoloMobile 43: deviceFamilyIsIntelAtom 48: deviceFamilyIsAlpha 49: deviceFamilyIsAlpha21064 50: deviceFamilyIsAlpha21066 51: deviceFamilyIsAlpha21164 52: deviceFamilyIsAlpha21164PC 53: deviceFamilyIsAlpha21164a 54: deviceFamilyIsAlpha21264 55: deviceFamilyIsAlpha21364 56: deviceFamilyIsAMDTurionIIUltraDualMobileM 57: deviceFamilyIsAMDTurionIIDualMobileM 58: deviceFamilyIsAMDAthlonIIDualMobileM 59: deviceFamilyIsAMDOpteron6100 60: deviceFamilyIsAMDOpteron4100 61: deviceFamilyIsAMDOpteron6200 62: deviceFamilyIsAMDOpteron4200 64: deviceFamilyIsMIPS 65: deviceFamilyIsMIPSR4000 66: deviceFamilyIsMIPSR4200 67: deviceFamilyIsMIPSR4400 68: deviceFamilyIsMIPSR4600 69: deviceFamilyIsMIPSR10000 80: deviceFamilyIsSPARC 81: deviceFamilyIsSuperSPARC 82: deviceFamilyIsmicroSPARCII 83: deviceFamilyIsmicroSPARCIIep 84: deviceFamilyIsUltraSPARC 85: deviceFamilyIsUltraSPARCII 86: deviceFamilyIsUltraSPARCIIi 87: deviceFamilyIsUltraSPARCIII 88: deviceFamilyIsUltraSPARCIIIi 96: deviceFamilyIs68040 97: deviceFamilyIs68xxx 98: deviceFamilyIs68000 99: deviceFamilyIs68010 100: deviceFamilyIs68020 101: deviceFamilyIs68030 107: deviceFamilyIsAMDZen 112: deviceFamilyIsHobbit 120: deviceFamilyIsCrusoeTM5000 121: deviceFamilyIsCrusoeTM3000 122: deviceFamilyIsEfficeonTM8000 128: deviceFamilyIsWeitek 130: deviceFamilyIsIntelCeleronM 131: deviceFamilyIsAMDAthlon64 132: deviceFamilyIsAMDOpteron 133: deviceFamilyIsAMDSempron 134: deviceFamilyIsAMDTurion64Mobile 135: deviceFamilyIsDualCoreAMDOpteron 136: deviceFamilyIsAMDAthlon64X2DualCore 137: deviceFamilyIsAMDTurion64X2Mobile 138: deviceFamilyIsQuadCoreAMDOpteron 139: deviceFamilyIsThirdGenerationAMDOpteron 140: deviceFamilyIsAMDPhenomFXQuadCore 141: deviceFamilyIsAMDPhenomX4QuadCore 142: deviceFamilyIsAMDPhenomX2DualCore 143: deviceFamilyIsAMDAthlonX2DualCore 144: deviceFamilyIsPARISC 145: deviceFamilyIsPARISC8500 146: deviceFamilyIsPARISC8000 147: deviceFamilyIsPARISC7300LC 148: deviceFamilyIsPARISC7200 149: deviceFamilyIsPARISC7100LC 150: deviceFamilyIsPARISC7100 160: deviceFamilyIsV30 161: deviceFamilyIsQuadCoreIntelXeon3200 162: deviceFamilyIsDualCoreIntelXeon3000 163: deviceFamilyIsQuadCoreIntelXeon5300 164: deviceFamilyIsDualCoreIntelXeon5100 165: deviceFamilyIsDualCoreIntelXeon5000 166: deviceFamilyIsDualCoreIntelXeonLV 167: deviceFamilyIsDualCoreIntelXeonULV 168: deviceFamilyIsDualCoreIntelXeon7100 169: deviceFamilyIsQuadCoreIntelXeon5400 170: deviceFamilyIsQuadCoreIntelXeon 171: deviceFamilyIsDualCoreIntelXeon5200 172: deviceFamilyIsDualCoreIntelXeon7200 173: deviceFamilyIsQuadCoreIntelXeon7300 174: deviceFamilyIsQuadCoreIntelXeon7400 175: deviceFamilyIsMultiCoreIntelXeon7400 176: deviceFamilyIsM1 177: deviceFamilyIsM2 179: deviceFamilyIsIntelPentium4HT 180: deviceFamilyIsAS400 182: deviceFamilyIsAMDAthlonXP 183: deviceFamilyIsAMDAthlonMP 184: deviceFamilyIsAMDDuron 185: deviceFamilyIsIntelPentiumM 186: deviceFamilyIsIntelCeleronD 187: deviceFamilyIsIntelPentiumD 188: deviceFamilyIsIntelPentiumExtreme 189: deviceFamilyIsIntelCoreSolo 190: deviceFamilyIsIntelCore2 191: deviceFamilyIsIntelCore2Duo 192: deviceFamilyIsIntelCore2Solo 193: deviceFamilyIsIntelCore2Extreme 194: deviceFamilyIsIntelCore2Quad 195: deviceFamilyIsIntelCore2ExtremeMobile 196: deviceFamilyIsIntelCore2DuoMobile 197: deviceFamilyIsIntelCore2SoloMobile 198: deviceFamilyIsIntelCorei7 199: deviceFamilyIsDualCoreIntelCeleron 200: deviceFamilyIsIBM390 201: deviceFamilyIsG4 202: deviceFamilyIsG5 203: deviceFamilyIsESA390G6 204: deviceFamilyIszArchitectur 205: deviceFamilyIsIntelCorei5 206: deviceFamilyIsIntelCorei3 210: deviceFamilyIsVIAC7M 211: deviceFamilyIsVIAC7D 212: deviceFamilyIsVIAC7 213: deviceFamilyIsVIAEden 214: deviceFamilyIsMultiCoreIntelXeon 215: deviceFamilyIsDualCoreIntelXeon3xxx 216: deviceFamilyIsQuadCoreIntelXeon3xxx 217: deviceFamilyIsVIANano 218: deviceFamilyIsDualCoreIntelXeon5xxx 219: deviceFamilyIsQuadCoreIntelXeon5xxx 221: deviceFamilyIsDualCoreIntelXeon7xxx 222: deviceFamilyIsQuadCoreIntelXeon7xxx 223: deviceFamilyIsMultiCoreIntelXeon7xxx 224: deviceFamilyIsMultiCoreIntelXeon3400 230: deviceFamilyIsEmbeddedAMDOpertonQuadCore 231: deviceFamilyIsAMDPhenomTripleCore 232: deviceFamilyIsAMDTurionUltraDualCoreMobile 233: deviceFamilyIsAMDTurionDualCoreMobile 234: deviceFamilyIsAMDAthlonDualCore 235: deviceFamilyIsAMDSempronSI 236: deviceFamilyIsAMDPhenomII 237: deviceFamilyIsAMDAthlonII 238: deviceFamilyIsSixCoreAMDOpteron 239: deviceFamilyIsAMDSempronM 250: deviceFamilyIsi860 251: deviceFamilyIsi960 - name: processorDeviceMaximumSpeed oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11 type: gauge help: 1100.0030.0001.0011 This attribute defines the maximum speed of the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceCurrentSpeed oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12 type: gauge help: 1100.0030.0001.0012 This attribute defines the current speed of the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceExternalClockSpeed oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13 type: gauge help: 1100.0030.0001.0013 This attribute defines the speed of the external clock for the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceVoltage oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14 type: gauge help: 1100.0030.0001.0014 This attribute defines the voltage powering the processor device in millivolts - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceVersionName oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16 type: OctetString help: 1100.0030.0001.0016 This attribute defines the version of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceCoreCount oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17 type: gauge help: 1100.0030.0001.0017 This attribute defines the number of processor cores detected for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceCoreEnabledCount oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18 type: gauge help: 1100.0030.0001.0018 This attribute defines the number of processor cores enabled for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceThreadCount oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19 type: gauge help: 1100.0030.0001.0019 This attribute defines the number of processor threads detected for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceCharacteristics oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20 type: gauge help: 1100.0030.0001.0020 This attribute defines characteristics of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceExtendedCapabilities oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21 type: gauge help: 1100.0030.0001.0021 This attribute defines extended capabilities of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceExtendedSettings oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22 type: gauge help: 1100.0030.0001.0022 This attribute defines extended settings of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceBrandName oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23 type: OctetString help: 1100.0030.0001.0023 This attribute defines the brand of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceFQDD oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 type: OctetString help: 1100.0030.0001.0026 Fully qualified device descriptor (FQDD) of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: memoryDeviceSize oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14 type: gauge help: 1100.0050.0001.0014 This attribute defines the size in KBytes of the memory device - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14 indexes: - labelname: memoryDevicechassisIndex type: gauge - labelname: memoryDeviceIndex type: gauge - name: systemStatechassisIndex oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.1 type: gauge help: 0200.0010.0001.0001 This attribute defines the index (one based) of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.1 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateGlobalSystemStatus oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.2 type: gauge help: 0200.0010.0001.0002 This attribute defines the global system status of all system chassis being monitored by the systems management software. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.2 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateChassisState oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.3 type: gauge help: 0200.0010.0001.0003 This attribute defines the state settings of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.3 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: unknown 2: enabled 4: notReady 6: enabledAndNotReady - name: systemStateChassisStatus oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.4 type: gauge help: 0200.0010.0001.0004 This attribute defines the status of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.4 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStatePowerUnitStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.5 type: OctetString help: 0200.0010.0001.0005 This attribute lists the state settings of each power unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.5 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStatePowerUnitStatusRedundancy oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.6 type: gauge help: 0200.0010.0001.0006 This attribute defines the combined redundancy status of all power units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.6 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: full 4: degraded 5: lost 6: notRedundant 7: redundancyOffline - name: systemStatePowerUnitStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.7 type: OctetString help: 0200.0010.0001.0007 This attribute lists the redundancy status of each power unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.7 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStatePowerSupplyStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.8 type: OctetString help: 0200.0010.0001.0008 This attribute lists the state settings of each power supply of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.8 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStatePowerSupplyStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.9 type: gauge help: 0200.0010.0001.0009 This attribute defines the combined status of all power supplies of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.9 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStatePowerSupplyStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.10 type: OctetString help: 0200.0010.0001.0010 This attribute lists the status of each power supply of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.10 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateVoltageStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.11 type: OctetString help: 0200.0010.0001.0011 This attribute lists the state settings of each voltage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.11 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateVoltageStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.12 type: gauge help: 0200.0010.0001.0012 This attribute defines the combined status of all voltage probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.12 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateVoltageStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.13 type: OctetString help: 0200.0010.0001.0013 This attribute lists the status of each voltage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.13 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateAmperageStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.14 type: OctetString help: 0200.0010.0001.0014 This attribute lists the state settings of each amperage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.14 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateAmperageStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.15 type: gauge help: 0200.0010.0001.0015 This attribute defines the combined status of all amperage probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.15 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateAmperageStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.16 type: OctetString help: 0200.0010.0001.0016 This attribute lists the status of each amperage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.16 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingUnitStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.17 type: OctetString help: 0200.0010.0001.0017 This attribute lists the state settings of each cooling unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.17 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingUnitStatusRedundancy oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.18 type: gauge help: 0200.0010.0001.0018 This attribute defines the combined redundancy status of all cooling units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.18 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: full 4: degraded 5: lost 6: notRedundant 7: redundancyOffline - name: systemStateCoolingUnitStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.19 type: OctetString help: 0200.0010.0001.0019 This attribute lists the redundancy status of each cooling unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.19 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingDeviceStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.20 type: OctetString help: 0200.0010.0001.0020 This attribute lists the state settings of each cooling device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.20 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.21 type: gauge help: 0200.0010.0001.0021 This attribute defines the combined status of all cooling devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.21 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateCoolingDeviceStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.22 type: OctetString help: 0200.0010.0001.0022 This attribute lists the status of each cooling device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.22 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateTemperatureStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.23 type: OctetString help: 0200.0010.0001.0023 This attribute lists the state settings of each temperature probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.23 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateTemperatureStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.24 type: gauge help: 0200.0010.0001.0024 This attribute defines the combined status of all temperature probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.24 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateTemperatureStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.25 type: OctetString help: 0200.0010.0001.0025 This attribute lists the status of each temperature probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.25 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateMemoryDeviceStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.26 type: OctetString help: 0200.0010.0001.0026 This attribute lists the state settings of each memory device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.26 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateMemoryDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.27 type: gauge help: 0200.0010.0001.0027 This attribute defines the combined status of all memory devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.27 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateMemoryDeviceStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.28 type: OctetString help: 0200.0010.0001.0028 This attribute lists the status of each memory device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.28 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateChassisIntrusionStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.29 type: OctetString help: 0200.0010.0001.0029 This attribute lists the state settings of each intrusion detection device of this system chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.29 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateChassisIntrusionStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.30 type: gauge help: 0200.0010.0001.0030 This attribute defines the combined status of all intrusion detection devices of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.30 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateChassisIntrusionStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.31 type: OctetString help: 0200.0010.0001.0031 This attribute lists the status of each intrusion detection device of this system chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.31 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStatePowerUnitStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.42 type: gauge help: 0200.0010.0001.0042 This attribute defines the combined status of all power units of this chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.42 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStatePowerUnitStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.43 type: OctetString help: 0200.0010.0001.0043 This attribute lists the status of each power unit of this chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.43 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingUnitStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.44 type: gauge help: 0200.0010.0001.0044 This attribute defines the combined status of all cooling units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.44 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateCoolingUnitStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.45 type: OctetString help: 0200.0010.0001.0045 This attribute lists the status of each cooling unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.45 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateProcessorDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.50 type: gauge help: 0200.0010.0001.0050 This attribute defines the combined status of all processor devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.50 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateProcessorDeviceStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.51 type: OctetString help: 0200.0010.0001.0051 This attribute lists the status of each processor device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.51 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateBatteryStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.52 type: gauge help: 0200.0010.0001.0052 This attribute defines the combined status of all batteries of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.52 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateBatteryStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.53 type: OctetString help: 0200.0010.0001.0053 This attribute lists the status of each battery of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.53 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateSDCardUnitStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.54 type: gauge help: 0200.0010.0001.0054 This attribute defines the combined status of all SD Card units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.54 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateSDCardUnitStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.55 type: OctetString help: 0200.0010.0001.0055 This attribute lists the status of each SD Card unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.55 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateSDCardDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.56 type: gauge help: 0200.0010.0001.0056 This attribute defines the combined status of all SD Card devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.56 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateSDCardDeviceStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.57 type: OctetString help: 0200.0010.0001.0057 This attribute lists the status of each SD Card device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.57 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateIDSDMCardUnitStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.58 type: gauge help: 0200.0010.0001.0058 This attribute defines the combined status of all IDSDM Card units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.58 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateIDSDMCardUnitStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.59 type: OctetString help: 0200.0010.0001.0059 This attribute lists the status of each IDSDM Card unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.59 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateIDSDMCardDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.60 type: gauge help: 0200.0010.0001.0060 This attribute defines the combined status of all IDSDM Card devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.60 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateIDSDMCardDeviceStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.61 type: OctetString help: 0200.0010.0001.0061 This attribute lists the status of each IDSDM Card device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.61 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateTemperatureStatisticsStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.62 type: OctetString help: 0200.0010.0001.0062 This attribute lists the state settings of each temperature statistics object of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.62 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateTemperatureStatisticsStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.63 type: gauge help: 0200.0010.0001.0063 This attribute defines the combined status of all temperature statistics objects of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.63 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateTemperatureStatisticsStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.64 type: OctetString help: 0200.0010.0001.0064 This attribute lists the status of each temperature statistics object of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.64 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCMCStatus oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.65 type: gauge help: 0200.0010.0001.0065 This attribute defines the status of CMC. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.65 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemBIOSStatus oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5 type: gauge help: 0300.0050.0001.0005 This attribute defines the status of the system BIOS. - 1.3.6.1.4.1.674.10892.5.4.300.50.1.5 indexes: - labelname: systemBIOSchassisIndex type: gauge - labelname: systemBIOSIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: powerSupplychassisIndex oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.1 type: gauge help: 0600.0012.0001.0001 This attribute defines the index (one based) of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.1 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyIndex oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.2 type: gauge help: 0600.0012.0001.0002 This attribute defines the index (one based) of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.2 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyStateCapabilitiesUnique oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.3 type: gauge help: 0600.0012.0001.0003 This attribute defines the state capabilities of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.3 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: unknown 2: onlineCapable 4: notReadyCapable - name: powerSupplyStateSettingsUnique oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.4 type: gauge help: 0600.0012.0001.0004 This attribute defines the state settings of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.4 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: unknown 2: onLine 4: notReady 8: fanFailure 10: onlineAndFanFailure 16: powerSupplyIsON 32: powerSupplyIsOK 64: acSwitchIsON 66: onlineandAcSwitchIsON 128: acPowerIsON 130: onlineAndAcPowerIsON 210: onlineAndPredictiveFailure 242: acPowerAndSwitchAreOnPowerSupplyIsOnIsOkAndOnline - name: powerSupplyStatus oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.5 type: gauge help: 0600.0012.0001.0005 This attribute defines the status of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.5 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: powerSupplyOutputWatts oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.6 type: gauge help: 0600.0012.0001.0006 This attribute defines the maximum sustained output wattage of the power supply (in tenths of Watts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.6 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyType oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.7 type: gauge help: 0600.0012.0001.0007 This attribute defines the type of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.7 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: powerSupplyTypeIsOther 2: powerSupplyTypeIsUnknown 3: powerSupplyTypeIsLinear 4: powerSupplyTypeIsSwitching 5: powerSupplyTypeIsBattery 6: powerSupplyTypeIsUPS 7: powerSupplyTypeIsConverter 8: powerSupplyTypeIsRegulator 9: powerSupplyTypeIsAC 10: powerSupplyTypeIsDC 11: powerSupplyTypeIsVRM - name: powerSupplyLocationName oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 type: OctetString help: 0600.0012.0001.0008 This attribute defines the location of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyMaximumInputVoltage oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.9 type: gauge help: 0600.0012.0001.0009 This attribute defines the maximum input voltage of the power supply (in Volts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.9 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplypowerUnitIndexReference oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.10 type: gauge help: 0600.0012.0001.0010 This attribute defines the index to the associated power unit if the power supply is part of a power unit. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.10 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplySensorState oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.11 type: gauge help: 0600.0012.0001.0011 This attribute defines the state reported by the power supply sensor - 1.3.6.1.4.1.674.10892.5.4.600.12.1.11 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: presenceDetected 2: psFailureDetected 4: predictiveFailure 8: psACLost 16: acLostOrOutOfRange 32: acOutOfRangeButPresent 64: configurationError - name: powerSupplyConfigurationErrorType oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.12 type: gauge help: 0600.0012.0001.0012 This attribute defines the type of configuration error reported by the power supply sensor - 1.3.6.1.4.1.674.10892.5.4.600.12.1.12 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: vendorMismatch 2: revisionMismatch 3: processorMissing - name: powerSupplyPowerMonitorCapable oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.13 type: gauge help: 0600.0012.0001.0013 This attribute defines a boolean value that reports whether the power supply is capable of monitoring power consumption. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.13 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyRatedInputWattage oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.14 type: gauge help: 0600.0012.0001.0014 This attribute defines the rated input wattage of the power supply (in tenths of Watts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.14 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyFQDD oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.15 type: OctetString help: 0600.0012.0001.0015 Fully qualified device descriptor (FQDD) of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.15 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyCurrentInputVoltage oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.16 type: gauge help: 0600.0012.0001.0016 This attribute defines the current input voltage to the power supply (in Volts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.16 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: amperageProbeReading oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6 type: gauge help: 0600.0030.0001.0006 This attribute defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.600.30.1.6 indexes: - labelname: amperageProbechassisIndex type: gauge - labelname: amperageProbeIndex type: gauge - name: temperatureProbechassisIndex oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.1 type: gauge help: 0700.0020.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.1 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeIndex oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.2 type: gauge help: 0700.0020.0001.0002 This attribute defines the index (one based) of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.2 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeStateCapabilities oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.3 type: gauge help: 0700.0020.0001.0003 This attribute defines the state capabilities of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.3 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: unknownCapabilities 2: enableCapable 4: notReadyCapable 6: enableAndNotReadyCapable - name: temperatureProbeStateSettings oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.4 type: gauge help: 0700.0020.0001.0004 This attribute defines the state settings of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.4 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: unknown 2: enabled 4: notReady 6: enabledAndNotReady - name: temperatureProbeStatus oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5 type: gauge help: 0700.0020.0001.0005 This attribute defines the probe status of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.5 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCriticalUpper 5: criticalUpper 6: nonRecoverableUpper 7: nonCriticalLower 8: criticalLower 9: nonRecoverableLower 10: failed - name: temperatureProbeReading oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.6 type: gauge help: 0700.0020.0001.0006 This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.20.1.6 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeType oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.7 type: gauge help: 0700.0020.0001.0007 This attribute defines the type of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.7 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: temperatureProbeTypeIsOther 2: temperatureProbeTypeIsUnknown 3: temperatureProbeTypeIsAmbientESM 16: temperatureProbeTypeIsDiscrete - name: temperatureProbeLocationName oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.8 type: DisplayString help: 0700.0020.0001.0008 This attribute defines the location name of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.8 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeUpperNonRecoverableThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.9 type: gauge help: 0700.0020.0001.0009 This attribute defines the upper nonrecoverable threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.9 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeUpperCriticalThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.10 type: gauge help: 0700.0020.0001.0010 This attribute defines the upper critical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.10 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeUpperNonCriticalThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.11 type: gauge help: 0700.0020.0001.0011 This attribute defines the upper noncritical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.11 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeLowerNonCriticalThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.12 type: gauge help: 0700.0020.0001.0012 This attribute defines the lower noncritical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.12 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeLowerCriticalThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.13 type: gauge help: 0700.0020.0001.0013 This attribute defines the lower critical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.13 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeLowerNonRecoverableThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.14 type: gauge help: 0700.0020.0001.0014 This attribute defines the lower nonrecoverable threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.14 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeProbeCapabilities oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.15 type: gauge help: 0700.0020.0001.0015 This attribute defines the probe capabilities of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.15 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: upperNonCriticalThresholdSetCapable 2: lowerNonCriticalThresholdSetCapable 4: upperNonCriticalThresholdDefaultCapable 8: lowerNonCriticalThresholdDefaultCapable - name: temperatureProbeDiscreteReading oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.16 type: gauge help: 0700.0020.0001.0016 This attribute defines the reading for a temperature probe of type temperatureProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.20.1.16 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: temperatureIsGood 2: temperatureIsBad - name: physicalDiskCapacityInMB oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11 type: gauge help: The size of the physical disk in megabytes. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11 indexes: - labelname: physicalDiskNumber type: gauge - name: physicalDiskComponentStatus oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 type: gauge help: The status of the physical disk itself without the propagation of any contained component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 indexes: - labelname: physicalDiskNumber type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: physicalDiskDisplayName oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55 type: DisplayString help: The physical disk's friendly FQDD as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55 indexes: - labelname: physicalDiskNumber type: gauge - name: physicalDiskProductID oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6 type: DisplayString help: The model number of the physical disk. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6 indexes: - labelname: physicalDiskNumber type: gauge - name: physicalDiskSerialNo oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 type: DisplayString help: The physical disk's unique identification number from the manufacturer. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 indexes: - labelname: physicalDiskNumber type: gauge version: 2 auth: community: public dell_sim: walk: - 1.3.6.1.4.1.674.10892.5.2 - 1.3.6.1.4.1.674.10892.5.4.1100.30 - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14 - 1.3.6.1.4.1.674.10892.5.4.200 - 1.3.6.1.4.1.674.10892.5.4.600.12.1 - 1.3.6.1.4.1.674.10892.5.4.600.30.1.6 - 1.3.6.1.4.1.674.10892.5.4.700.20.1 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 get: - 1.3.6.1.2.1.1.3.0 - 1.3.6.1.4.1.674.10892.5.4.300.50.1.5.1.1 metrics: - name: sysUpTime oid: 1.3.6.1.2.1.1.3 type: gauge help: The time (in hundredths of a second) since the network management portion of the system was last re-initialized. - 1.3.6.1.2.1.1.3 - name: globalSystemStatus oid: 1.3.6.1.4.1.674.10892.5.2.1 type: gauge help: This attribute defines the overall rollup status of all components in the system being monitored by the remote access card - 1.3.6.1.4.1.674.10892.5.2.1 enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemLCDStatus oid: 1.3.6.1.4.1.674.10892.5.2.2 type: gauge help: This attribute defines the system status as it is reflected by the LCD front panel - 1.3.6.1.4.1.674.10892.5.2.2 enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: globalStorageStatus oid: 1.3.6.1.4.1.674.10892.5.2.3 type: gauge help: This attribute defines the overall storage status being monitored by the remote access card. - 1.3.6.1.4.1.674.10892.5.2.3 enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemPowerState oid: 1.3.6.1.4.1.674.10892.5.2.4 type: gauge help: This attribute defines the power state of the system. - 1.3.6.1.4.1.674.10892.5.2.4 enum_values: 1: other 2: unknown 3: "off" 4: "on" - name: systemPowerUpTime oid: 1.3.6.1.4.1.674.10892.5.2.5 type: gauge help: This attribute defines the power-up time of the system in seconds. - 1.3.6.1.4.1.674.10892.5.2.5 - name: processorDevicechassisIndex oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1 type: gauge help: 1100.0030.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceIndex oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2 type: gauge help: 1100.0030.0001.0002 This attribute defines the index (one based) of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceStateCapabilities oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3 type: gauge help: 1100.0030.0001.0003 This attribute defines the state capabilities of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: unknownCapabilities 2: enableCapable 4: notReadyCapable 6: enableAndNotReadyCapable - name: processorDeviceStateSettings oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4 type: gauge help: 1100.0030.0001.0004 This attribute defines the state settings of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: unknown 2: enabled 4: notReady 6: enabledAndNotReady - name: processorDeviceStatus oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5 type: gauge help: 1100.0030.0001.0005 This attribute defines the status of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: processorDeviceType oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7 type: gauge help: 1100.0030.0001.0007 This attribute defines the type of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: deviceTypeIsOther 2: deviceTypeIsUnknown 3: deviceTypeIsCPU 4: deviceTypeIsMathProcessor 5: deviceTypeIsDSP 6: deviceTypeIsAVideoProcessor - name: processorDeviceManufacturerName oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8 type: OctetString help: 1100.0030.0001.0008 This attribute defines the name of the manufacturer of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceStatusState oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9 type: gauge help: 1100.0030.0001.0009 This attribute defines the status state of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: other 2: unknown 3: enabled 4: userDisabled 5: biosDisabled 6: idle - name: processorDeviceFamily oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10 type: gauge help: 1100.0030.0001.0010 This attribute defines the family of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: deviceFamilyIsOther 2: deviceFamilyIsUnknown 3: deviceFamilyIs8086 4: deviceFamilyIs80286 5: deviceFamilyIsIntel386 6: deviceFamilyIsIntel486 7: deviceFamilyIs8087 8: deviceFamilyIs80287 9: deviceFamilyIs80387 10: deviceFamilyIs80487 11: deviceFamilyIsPentium 12: deviceFamilyIsPentiumPro 13: deviceFamilyIsPentiumII 14: deviceFamilyIsPentiumMMX 15: deviceFamilyIsCeleron 16: deviceFamilyIsPentiumIIXeon 17: deviceFamilyIsPentiumIII 18: deviceFamilyIsPentiumIIIXeon 19: deviceFamilyIsPentiumIIISpeedStep 20: deviceFamilyIsItanium 21: deviceFamilyIsIntelXeon 22: deviceFamilyIsPentium4 23: deviceFamilyIsIntelXeonMP 24: deviceFamilyIsIntelItanium2 25: deviceFamilyIsK5 26: deviceFamilyIsK6 27: deviceFamilyIsK6Dash2 28: deviceFamilyIsK6Dash3 29: deviceFamilyIsAMDAthlon 30: deviceFamilyIsAMD2900 31: deviceFamilyIsK6Dash2Plus 32: deviceFamilyIsPowerPC 33: deviceFamilyIsPowerPC601 34: deviceFamilyIsPowerPC603 35: deviceFamilyIsPowerPC603Plus 36: deviceFamilyIsPowerPC604 37: deviceFamilyIsPowerPC620 38: deviceFamilyIsPowerPCx704 39: deviceFamilyIsPowerPC750 40: deviceFamilyIsIntelCoreDuo 41: deviceFamilyIsIntelCoreDuoMobile 42: deviceFamilyIsIntelCoreSoloMobile 43: deviceFamilyIsIntelAtom 48: deviceFamilyIsAlpha 49: deviceFamilyIsAlpha21064 50: deviceFamilyIsAlpha21066 51: deviceFamilyIsAlpha21164 52: deviceFamilyIsAlpha21164PC 53: deviceFamilyIsAlpha21164a 54: deviceFamilyIsAlpha21264 55: deviceFamilyIsAlpha21364 56: deviceFamilyIsAMDTurionIIUltraDualMobileM 57: deviceFamilyIsAMDTurionIIDualMobileM 58: deviceFamilyIsAMDAthlonIIDualMobileM 59: deviceFamilyIsAMDOpteron6100 60: deviceFamilyIsAMDOpteron4100 61: deviceFamilyIsAMDOpteron6200 62: deviceFamilyIsAMDOpteron4200 64: deviceFamilyIsMIPS 65: deviceFamilyIsMIPSR4000 66: deviceFamilyIsMIPSR4200 67: deviceFamilyIsMIPSR4400 68: deviceFamilyIsMIPSR4600 69: deviceFamilyIsMIPSR10000 80: deviceFamilyIsSPARC 81: deviceFamilyIsSuperSPARC 82: deviceFamilyIsmicroSPARCII 83: deviceFamilyIsmicroSPARCIIep 84: deviceFamilyIsUltraSPARC 85: deviceFamilyIsUltraSPARCII 86: deviceFamilyIsUltraSPARCIIi 87: deviceFamilyIsUltraSPARCIII 88: deviceFamilyIsUltraSPARCIIIi 96: deviceFamilyIs68040 97: deviceFamilyIs68xxx 98: deviceFamilyIs68000 99: deviceFamilyIs68010 100: deviceFamilyIs68020 101: deviceFamilyIs68030 107: deviceFamilyIsAMDZen 112: deviceFamilyIsHobbit 120: deviceFamilyIsCrusoeTM5000 121: deviceFamilyIsCrusoeTM3000 122: deviceFamilyIsEfficeonTM8000 128: deviceFamilyIsWeitek 130: deviceFamilyIsIntelCeleronM 131: deviceFamilyIsAMDAthlon64 132: deviceFamilyIsAMDOpteron 133: deviceFamilyIsAMDSempron 134: deviceFamilyIsAMDTurion64Mobile 135: deviceFamilyIsDualCoreAMDOpteron 136: deviceFamilyIsAMDAthlon64X2DualCore 137: deviceFamilyIsAMDTurion64X2Mobile 138: deviceFamilyIsQuadCoreAMDOpteron 139: deviceFamilyIsThirdGenerationAMDOpteron 140: deviceFamilyIsAMDPhenomFXQuadCore 141: deviceFamilyIsAMDPhenomX4QuadCore 142: deviceFamilyIsAMDPhenomX2DualCore 143: deviceFamilyIsAMDAthlonX2DualCore 144: deviceFamilyIsPARISC 145: deviceFamilyIsPARISC8500 146: deviceFamilyIsPARISC8000 147: deviceFamilyIsPARISC7300LC 148: deviceFamilyIsPARISC7200 149: deviceFamilyIsPARISC7100LC 150: deviceFamilyIsPARISC7100 160: deviceFamilyIsV30 161: deviceFamilyIsQuadCoreIntelXeon3200 162: deviceFamilyIsDualCoreIntelXeon3000 163: deviceFamilyIsQuadCoreIntelXeon5300 164: deviceFamilyIsDualCoreIntelXeon5100 165: deviceFamilyIsDualCoreIntelXeon5000 166: deviceFamilyIsDualCoreIntelXeonLV 167: deviceFamilyIsDualCoreIntelXeonULV 168: deviceFamilyIsDualCoreIntelXeon7100 169: deviceFamilyIsQuadCoreIntelXeon5400 170: deviceFamilyIsQuadCoreIntelXeon 171: deviceFamilyIsDualCoreIntelXeon5200 172: deviceFamilyIsDualCoreIntelXeon7200 173: deviceFamilyIsQuadCoreIntelXeon7300 174: deviceFamilyIsQuadCoreIntelXeon7400 175: deviceFamilyIsMultiCoreIntelXeon7400 176: deviceFamilyIsM1 177: deviceFamilyIsM2 179: deviceFamilyIsIntelPentium4HT 180: deviceFamilyIsAS400 182: deviceFamilyIsAMDAthlonXP 183: deviceFamilyIsAMDAthlonMP 184: deviceFamilyIsAMDDuron 185: deviceFamilyIsIntelPentiumM 186: deviceFamilyIsIntelCeleronD 187: deviceFamilyIsIntelPentiumD 188: deviceFamilyIsIntelPentiumExtreme 189: deviceFamilyIsIntelCoreSolo 190: deviceFamilyIsIntelCore2 191: deviceFamilyIsIntelCore2Duo 192: deviceFamilyIsIntelCore2Solo 193: deviceFamilyIsIntelCore2Extreme 194: deviceFamilyIsIntelCore2Quad 195: deviceFamilyIsIntelCore2ExtremeMobile 196: deviceFamilyIsIntelCore2DuoMobile 197: deviceFamilyIsIntelCore2SoloMobile 198: deviceFamilyIsIntelCorei7 199: deviceFamilyIsDualCoreIntelCeleron 200: deviceFamilyIsIBM390 201: deviceFamilyIsG4 202: deviceFamilyIsG5 203: deviceFamilyIsESA390G6 204: deviceFamilyIszArchitectur 205: deviceFamilyIsIntelCorei5 206: deviceFamilyIsIntelCorei3 210: deviceFamilyIsVIAC7M 211: deviceFamilyIsVIAC7D 212: deviceFamilyIsVIAC7 213: deviceFamilyIsVIAEden 214: deviceFamilyIsMultiCoreIntelXeon 215: deviceFamilyIsDualCoreIntelXeon3xxx 216: deviceFamilyIsQuadCoreIntelXeon3xxx 217: deviceFamilyIsVIANano 218: deviceFamilyIsDualCoreIntelXeon5xxx 219: deviceFamilyIsQuadCoreIntelXeon5xxx 221: deviceFamilyIsDualCoreIntelXeon7xxx 222: deviceFamilyIsQuadCoreIntelXeon7xxx 223: deviceFamilyIsMultiCoreIntelXeon7xxx 224: deviceFamilyIsMultiCoreIntelXeon3400 230: deviceFamilyIsEmbeddedAMDOpertonQuadCore 231: deviceFamilyIsAMDPhenomTripleCore 232: deviceFamilyIsAMDTurionUltraDualCoreMobile 233: deviceFamilyIsAMDTurionDualCoreMobile 234: deviceFamilyIsAMDAthlonDualCore 235: deviceFamilyIsAMDSempronSI 236: deviceFamilyIsAMDPhenomII 237: deviceFamilyIsAMDAthlonII 238: deviceFamilyIsSixCoreAMDOpteron 239: deviceFamilyIsAMDSempronM 250: deviceFamilyIsi860 251: deviceFamilyIsi960 - name: processorDeviceMaximumSpeed oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11 type: gauge help: 1100.0030.0001.0011 This attribute defines the maximum speed of the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceCurrentSpeed oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12 type: gauge help: 1100.0030.0001.0012 This attribute defines the current speed of the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceExternalClockSpeed oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13 type: gauge help: 1100.0030.0001.0013 This attribute defines the speed of the external clock for the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceVoltage oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14 type: gauge help: 1100.0030.0001.0014 This attribute defines the voltage powering the processor device in millivolts - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceVersionName oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16 type: OctetString help: 1100.0030.0001.0016 This attribute defines the version of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceCoreCount oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17 type: gauge help: 1100.0030.0001.0017 This attribute defines the number of processor cores detected for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceCoreEnabledCount oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18 type: gauge help: 1100.0030.0001.0018 This attribute defines the number of processor cores enabled for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceThreadCount oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19 type: gauge help: 1100.0030.0001.0019 This attribute defines the number of processor threads detected for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceCharacteristics oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20 type: gauge help: 1100.0030.0001.0020 This attribute defines characteristics of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceExtendedCapabilities oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21 type: gauge help: 1100.0030.0001.0021 This attribute defines extended capabilities of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceExtendedSettings oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22 type: gauge help: 1100.0030.0001.0022 This attribute defines extended settings of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceBrandName oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23 type: OctetString help: 1100.0030.0001.0023 This attribute defines the brand of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceFQDD oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 type: OctetString help: 1100.0030.0001.0026 Fully qualified device descriptor (FQDD) of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: memoryDeviceSize oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14 type: gauge help: 1100.0050.0001.0014 This attribute defines the size in KBytes of the memory device - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14 indexes: - labelname: memoryDevicechassisIndex type: gauge - labelname: memoryDeviceIndex type: gauge - name: systemStatechassisIndex oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.1 type: gauge help: 0200.0010.0001.0001 This attribute defines the index (one based) of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.1 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateGlobalSystemStatus oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.2 type: gauge help: 0200.0010.0001.0002 This attribute defines the global system status of all system chassis being monitored by the systems management software. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.2 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateChassisState oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.3 type: gauge help: 0200.0010.0001.0003 This attribute defines the state settings of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.3 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: unknown 2: enabled 4: notReady 6: enabledAndNotReady - name: systemStateChassisStatus oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.4 type: gauge help: 0200.0010.0001.0004 This attribute defines the status of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.4 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStatePowerUnitStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.5 type: OctetString help: 0200.0010.0001.0005 This attribute lists the state settings of each power unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.5 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStatePowerUnitStatusRedundancy oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.6 type: gauge help: 0200.0010.0001.0006 This attribute defines the combined redundancy status of all power units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.6 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: full 4: degraded 5: lost 6: notRedundant 7: redundancyOffline - name: systemStatePowerUnitStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.7 type: OctetString help: 0200.0010.0001.0007 This attribute lists the redundancy status of each power unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.7 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStatePowerSupplyStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.8 type: OctetString help: 0200.0010.0001.0008 This attribute lists the state settings of each power supply of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.8 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStatePowerSupplyStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.9 type: gauge help: 0200.0010.0001.0009 This attribute defines the combined status of all power supplies of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.9 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStatePowerSupplyStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.10 type: OctetString help: 0200.0010.0001.0010 This attribute lists the status of each power supply of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.10 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateVoltageStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.11 type: OctetString help: 0200.0010.0001.0011 This attribute lists the state settings of each voltage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.11 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateVoltageStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.12 type: gauge help: 0200.0010.0001.0012 This attribute defines the combined status of all voltage probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.12 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateVoltageStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.13 type: OctetString help: 0200.0010.0001.0013 This attribute lists the status of each voltage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.13 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateAmperageStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.14 type: OctetString help: 0200.0010.0001.0014 This attribute lists the state settings of each amperage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.14 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateAmperageStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.15 type: gauge help: 0200.0010.0001.0015 This attribute defines the combined status of all amperage probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.15 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateAmperageStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.16 type: OctetString help: 0200.0010.0001.0016 This attribute lists the status of each amperage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.16 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingUnitStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.17 type: OctetString help: 0200.0010.0001.0017 This attribute lists the state settings of each cooling unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.17 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingUnitStatusRedundancy oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.18 type: gauge help: 0200.0010.0001.0018 This attribute defines the combined redundancy status of all cooling units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.18 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: full 4: degraded 5: lost 6: notRedundant 7: redundancyOffline - name: systemStateCoolingUnitStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.19 type: OctetString help: 0200.0010.0001.0019 This attribute lists the redundancy status of each cooling unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.19 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingDeviceStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.20 type: OctetString help: 0200.0010.0001.0020 This attribute lists the state settings of each cooling device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.20 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.21 type: gauge help: 0200.0010.0001.0021 This attribute defines the combined status of all cooling devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.21 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateCoolingDeviceStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.22 type: OctetString help: 0200.0010.0001.0022 This attribute lists the status of each cooling device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.22 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateTemperatureStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.23 type: OctetString help: 0200.0010.0001.0023 This attribute lists the state settings of each temperature probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.23 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateTemperatureStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.24 type: gauge help: 0200.0010.0001.0024 This attribute defines the combined status of all temperature probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.24 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateTemperatureStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.25 type: OctetString help: 0200.0010.0001.0025 This attribute lists the status of each temperature probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.25 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateMemoryDeviceStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.26 type: OctetString help: 0200.0010.0001.0026 This attribute lists the state settings of each memory device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.26 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateMemoryDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.27 type: gauge help: 0200.0010.0001.0027 This attribute defines the combined status of all memory devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.27 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateMemoryDeviceStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.28 type: OctetString help: 0200.0010.0001.0028 This attribute lists the status of each memory device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.28 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateChassisIntrusionStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.29 type: OctetString help: 0200.0010.0001.0029 This attribute lists the state settings of each intrusion detection device of this system chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.29 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateChassisIntrusionStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.30 type: gauge help: 0200.0010.0001.0030 This attribute defines the combined status of all intrusion detection devices of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.30 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateChassisIntrusionStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.31 type: OctetString help: 0200.0010.0001.0031 This attribute lists the status of each intrusion detection device of this system chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.31 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStatePowerUnitStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.42 type: gauge help: 0200.0010.0001.0042 This attribute defines the combined status of all power units of this chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.42 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStatePowerUnitStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.43 type: OctetString help: 0200.0010.0001.0043 This attribute lists the status of each power unit of this chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.43 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingUnitStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.44 type: gauge help: 0200.0010.0001.0044 This attribute defines the combined status of all cooling units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.44 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateCoolingUnitStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.45 type: OctetString help: 0200.0010.0001.0045 This attribute lists the status of each cooling unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.45 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateProcessorDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.50 type: gauge help: 0200.0010.0001.0050 This attribute defines the combined status of all processor devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.50 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateProcessorDeviceStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.51 type: OctetString help: 0200.0010.0001.0051 This attribute lists the status of each processor device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.51 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateBatteryStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.52 type: gauge help: 0200.0010.0001.0052 This attribute defines the combined status of all batteries of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.52 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateBatteryStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.53 type: OctetString help: 0200.0010.0001.0053 This attribute lists the status of each battery of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.53 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateSDCardUnitStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.54 type: gauge help: 0200.0010.0001.0054 This attribute defines the combined status of all SD Card units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.54 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateSDCardUnitStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.55 type: OctetString help: 0200.0010.0001.0055 This attribute lists the status of each SD Card unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.55 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateSDCardDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.56 type: gauge help: 0200.0010.0001.0056 This attribute defines the combined status of all SD Card devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.56 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateSDCardDeviceStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.57 type: OctetString help: 0200.0010.0001.0057 This attribute lists the status of each SD Card device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.57 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateIDSDMCardUnitStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.58 type: gauge help: 0200.0010.0001.0058 This attribute defines the combined status of all IDSDM Card units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.58 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateIDSDMCardUnitStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.59 type: OctetString help: 0200.0010.0001.0059 This attribute lists the status of each IDSDM Card unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.59 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateIDSDMCardDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.60 type: gauge help: 0200.0010.0001.0060 This attribute defines the combined status of all IDSDM Card devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.60 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateIDSDMCardDeviceStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.61 type: OctetString help: 0200.0010.0001.0061 This attribute lists the status of each IDSDM Card device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.61 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateTemperatureStatisticsStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.62 type: OctetString help: 0200.0010.0001.0062 This attribute lists the state settings of each temperature statistics object of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.62 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateTemperatureStatisticsStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.63 type: gauge help: 0200.0010.0001.0063 This attribute defines the combined status of all temperature statistics objects of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.63 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateTemperatureStatisticsStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.64 type: OctetString help: 0200.0010.0001.0064 This attribute lists the status of each temperature statistics object of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.64 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCMCStatus oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.65 type: gauge help: 0200.0010.0001.0065 This attribute defines the status of CMC. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.65 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemBIOSStatus oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5 type: gauge help: 0300.0050.0001.0005 This attribute defines the status of the system BIOS. - 1.3.6.1.4.1.674.10892.5.4.300.50.1.5 indexes: - labelname: systemBIOSchassisIndex type: gauge - labelname: systemBIOSIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: powerSupplychassisIndex oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.1 type: gauge help: 0600.0012.0001.0001 This attribute defines the index (one based) of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.1 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyIndex oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.2 type: gauge help: 0600.0012.0001.0002 This attribute defines the index (one based) of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.2 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyStateCapabilitiesUnique oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.3 type: gauge help: 0600.0012.0001.0003 This attribute defines the state capabilities of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.3 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: unknown 2: onlineCapable 4: notReadyCapable - name: powerSupplyStateSettingsUnique oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.4 type: gauge help: 0600.0012.0001.0004 This attribute defines the state settings of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.4 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: unknown 2: onLine 4: notReady 8: fanFailure 10: onlineAndFanFailure 16: powerSupplyIsON 32: powerSupplyIsOK 64: acSwitchIsON 66: onlineandAcSwitchIsON 128: acPowerIsON 130: onlineAndAcPowerIsON 210: onlineAndPredictiveFailure 242: acPowerAndSwitchAreOnPowerSupplyIsOnIsOkAndOnline - name: powerSupplyStatus oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.5 type: gauge help: 0600.0012.0001.0005 This attribute defines the status of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.5 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: powerSupplyOutputWatts oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.6 type: gauge help: 0600.0012.0001.0006 This attribute defines the maximum sustained output wattage of the power supply (in tenths of Watts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.6 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyType oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.7 type: gauge help: 0600.0012.0001.0007 This attribute defines the type of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.7 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: powerSupplyTypeIsOther 2: powerSupplyTypeIsUnknown 3: powerSupplyTypeIsLinear 4: powerSupplyTypeIsSwitching 5: powerSupplyTypeIsBattery 6: powerSupplyTypeIsUPS 7: powerSupplyTypeIsConverter 8: powerSupplyTypeIsRegulator 9: powerSupplyTypeIsAC 10: powerSupplyTypeIsDC 11: powerSupplyTypeIsVRM - name: powerSupplyLocationName oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 type: OctetString help: 0600.0012.0001.0008 This attribute defines the location of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyMaximumInputVoltage oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.9 type: gauge help: 0600.0012.0001.0009 This attribute defines the maximum input voltage of the power supply (in Volts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.9 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplypowerUnitIndexReference oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.10 type: gauge help: 0600.0012.0001.0010 This attribute defines the index to the associated power unit if the power supply is part of a power unit. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.10 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplySensorState oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.11 type: gauge help: 0600.0012.0001.0011 This attribute defines the state reported by the power supply sensor - 1.3.6.1.4.1.674.10892.5.4.600.12.1.11 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: presenceDetected 2: psFailureDetected 4: predictiveFailure 8: psACLost 16: acLostOrOutOfRange 32: acOutOfRangeButPresent 64: configurationError - name: powerSupplyConfigurationErrorType oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.12 type: gauge help: 0600.0012.0001.0012 This attribute defines the type of configuration error reported by the power supply sensor - 1.3.6.1.4.1.674.10892.5.4.600.12.1.12 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: vendorMismatch 2: revisionMismatch 3: processorMissing - name: powerSupplyPowerMonitorCapable oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.13 type: gauge help: 0600.0012.0001.0013 This attribute defines a boolean value that reports whether the power supply is capable of monitoring power consumption. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.13 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyRatedInputWattage oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.14 type: gauge help: 0600.0012.0001.0014 This attribute defines the rated input wattage of the power supply (in tenths of Watts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.14 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyFQDD oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.15 type: OctetString help: 0600.0012.0001.0015 Fully qualified device descriptor (FQDD) of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.15 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyCurrentInputVoltage oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.16 type: gauge help: 0600.0012.0001.0016 This attribute defines the current input voltage to the power supply (in Volts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.16 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: amperageProbeReading oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6 type: gauge help: 0600.0030.0001.0006 This attribute defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.600.30.1.6 indexes: - labelname: amperageProbechassisIndex type: gauge - labelname: amperageProbeIndex type: gauge - name: temperatureProbechassisIndex oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.1 type: gauge help: 0700.0020.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.1 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeIndex oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.2 type: gauge help: 0700.0020.0001.0002 This attribute defines the index (one based) of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.2 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeStateCapabilities oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.3 type: gauge help: 0700.0020.0001.0003 This attribute defines the state capabilities of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.3 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: unknownCapabilities 2: enableCapable 4: notReadyCapable 6: enableAndNotReadyCapable - name: temperatureProbeStateSettings oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.4 type: gauge help: 0700.0020.0001.0004 This attribute defines the state settings of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.4 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: unknown 2: enabled 4: notReady 6: enabledAndNotReady - name: temperatureProbeStatus oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5 type: gauge help: 0700.0020.0001.0005 This attribute defines the probe status of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.5 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCriticalUpper 5: criticalUpper 6: nonRecoverableUpper 7: nonCriticalLower 8: criticalLower 9: nonRecoverableLower 10: failed - name: temperatureProbeReading oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.6 type: gauge help: 0700.0020.0001.0006 This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.20.1.6 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeType oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.7 type: gauge help: 0700.0020.0001.0007 This attribute defines the type of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.7 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: temperatureProbeTypeIsOther 2: temperatureProbeTypeIsUnknown 3: temperatureProbeTypeIsAmbientESM 16: temperatureProbeTypeIsDiscrete - name: temperatureProbeLocationName oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.8 type: DisplayString help: 0700.0020.0001.0008 This attribute defines the location name of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.8 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeUpperNonRecoverableThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.9 type: gauge help: 0700.0020.0001.0009 This attribute defines the upper nonrecoverable threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.9 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeUpperCriticalThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.10 type: gauge help: 0700.0020.0001.0010 This attribute defines the upper critical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.10 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeUpperNonCriticalThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.11 type: gauge help: 0700.0020.0001.0011 This attribute defines the upper noncritical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.11 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeLowerNonCriticalThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.12 type: gauge help: 0700.0020.0001.0012 This attribute defines the lower noncritical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.12 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeLowerCriticalThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.13 type: gauge help: 0700.0020.0001.0013 This attribute defines the lower critical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.13 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeLowerNonRecoverableThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.14 type: gauge help: 0700.0020.0001.0014 This attribute defines the lower nonrecoverable threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.14 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeProbeCapabilities oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.15 type: gauge help: 0700.0020.0001.0015 This attribute defines the probe capabilities of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.15 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: upperNonCriticalThresholdSetCapable 2: lowerNonCriticalThresholdSetCapable 4: upperNonCriticalThresholdDefaultCapable 8: lowerNonCriticalThresholdDefaultCapable - name: temperatureProbeDiscreteReading oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.16 type: gauge help: 0700.0020.0001.0016 This attribute defines the reading for a temperature probe of type temperatureProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.20.1.16 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: temperatureIsGood 2: temperatureIsBad - name: physicalDiskCapacityInMB oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11 type: gauge help: The size of the physical disk in megabytes. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11 indexes: - labelname: physicalDiskNumber type: gauge - name: physicalDiskComponentStatus oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 type: gauge help: The status of the physical disk itself without the propagation of any contained component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 indexes: - labelname: physicalDiskNumber type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: physicalDiskDisplayName oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55 type: DisplayString help: The physical disk's friendly FQDD as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55 indexes: - labelname: physicalDiskNumber type: gauge - name: physicalDiskProductID oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6 type: DisplayString help: The model number of the physical disk. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6 indexes: - labelname: physicalDiskNumber type: gauge - name: physicalDiskSerialNo oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 type: DisplayString help: The physical disk's unique identification number from the manufacturer. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 indexes: - labelname: physicalDiskNumber type: gauge version: 2 auth: community: dell_r740xd dell_walk: walk: - 1.3.6.1.4.1.674.10892.5.2 - 1.3.6.1.4.1.674.10892.5.4.1100.30 - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14 - 1.3.6.1.4.1.674.10892.5.4.200 - 1.3.6.1.4.1.674.10892.5.4.600.12.1 - 1.3.6.1.4.1.674.10892.5.4.600.30.1.6 - 1.3.6.1.4.1.674.10892.5.4.700.20.1 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6 - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 get: - 1.3.6.1.2.1.1.3.0 - 1.3.6.1.4.1.674.10892.5.4.300.50.1.5.1.1 metrics: - name: sysUpTime oid: 1.3.6.1.2.1.1.3 type: gauge help: The time (in hundredths of a second) since the network management portion of the system was last re-initialized. - 1.3.6.1.2.1.1.3 - name: globalSystemStatus oid: 1.3.6.1.4.1.674.10892.5.2.1 type: gauge help: This attribute defines the overall rollup status of all components in the system being monitored by the remote access card - 1.3.6.1.4.1.674.10892.5.2.1 enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemLCDStatus oid: 1.3.6.1.4.1.674.10892.5.2.2 type: gauge help: This attribute defines the system status as it is reflected by the LCD front panel - 1.3.6.1.4.1.674.10892.5.2.2 enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: globalStorageStatus oid: 1.3.6.1.4.1.674.10892.5.2.3 type: gauge help: This attribute defines the overall storage status being monitored by the remote access card. - 1.3.6.1.4.1.674.10892.5.2.3 enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemPowerState oid: 1.3.6.1.4.1.674.10892.5.2.4 type: gauge help: This attribute defines the power state of the system. - 1.3.6.1.4.1.674.10892.5.2.4 enum_values: 1: other 2: unknown 3: "off" 4: "on" - name: systemPowerUpTime oid: 1.3.6.1.4.1.674.10892.5.2.5 type: gauge help: This attribute defines the power-up time of the system in seconds. - 1.3.6.1.4.1.674.10892.5.2.5 - name: processorDevicechassisIndex oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1 type: gauge help: 1100.0030.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceIndex oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2 type: gauge help: 1100.0030.0001.0002 This attribute defines the index (one based) of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceStateCapabilities oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3 type: gauge help: 1100.0030.0001.0003 This attribute defines the state capabilities of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: unknownCapabilities 2: enableCapable 4: notReadyCapable 6: enableAndNotReadyCapable - name: processorDeviceStateSettings oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4 type: gauge help: 1100.0030.0001.0004 This attribute defines the state settings of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: unknown 2: enabled 4: notReady 6: enabledAndNotReady - name: processorDeviceStatus oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5 type: gauge help: 1100.0030.0001.0005 This attribute defines the status of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: processorDeviceType oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7 type: gauge help: 1100.0030.0001.0007 This attribute defines the type of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: deviceTypeIsOther 2: deviceTypeIsUnknown 3: deviceTypeIsCPU 4: deviceTypeIsMathProcessor 5: deviceTypeIsDSP 6: deviceTypeIsAVideoProcessor - name: processorDeviceManufacturerName oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8 type: OctetString help: 1100.0030.0001.0008 This attribute defines the name of the manufacturer of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceStatusState oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9 type: gauge help: 1100.0030.0001.0009 This attribute defines the status state of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: other 2: unknown 3: enabled 4: userDisabled 5: biosDisabled 6: idle - name: processorDeviceFamily oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10 type: gauge help: 1100.0030.0001.0010 This attribute defines the family of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge enum_values: 1: deviceFamilyIsOther 2: deviceFamilyIsUnknown 3: deviceFamilyIs8086 4: deviceFamilyIs80286 5: deviceFamilyIsIntel386 6: deviceFamilyIsIntel486 7: deviceFamilyIs8087 8: deviceFamilyIs80287 9: deviceFamilyIs80387 10: deviceFamilyIs80487 11: deviceFamilyIsPentium 12: deviceFamilyIsPentiumPro 13: deviceFamilyIsPentiumII 14: deviceFamilyIsPentiumMMX 15: deviceFamilyIsCeleron 16: deviceFamilyIsPentiumIIXeon 17: deviceFamilyIsPentiumIII 18: deviceFamilyIsPentiumIIIXeon 19: deviceFamilyIsPentiumIIISpeedStep 20: deviceFamilyIsItanium 21: deviceFamilyIsIntelXeon 22: deviceFamilyIsPentium4 23: deviceFamilyIsIntelXeonMP 24: deviceFamilyIsIntelItanium2 25: deviceFamilyIsK5 26: deviceFamilyIsK6 27: deviceFamilyIsK6Dash2 28: deviceFamilyIsK6Dash3 29: deviceFamilyIsAMDAthlon 30: deviceFamilyIsAMD2900 31: deviceFamilyIsK6Dash2Plus 32: deviceFamilyIsPowerPC 33: deviceFamilyIsPowerPC601 34: deviceFamilyIsPowerPC603 35: deviceFamilyIsPowerPC603Plus 36: deviceFamilyIsPowerPC604 37: deviceFamilyIsPowerPC620 38: deviceFamilyIsPowerPCx704 39: deviceFamilyIsPowerPC750 40: deviceFamilyIsIntelCoreDuo 41: deviceFamilyIsIntelCoreDuoMobile 42: deviceFamilyIsIntelCoreSoloMobile 43: deviceFamilyIsIntelAtom 48: deviceFamilyIsAlpha 49: deviceFamilyIsAlpha21064 50: deviceFamilyIsAlpha21066 51: deviceFamilyIsAlpha21164 52: deviceFamilyIsAlpha21164PC 53: deviceFamilyIsAlpha21164a 54: deviceFamilyIsAlpha21264 55: deviceFamilyIsAlpha21364 56: deviceFamilyIsAMDTurionIIUltraDualMobileM 57: deviceFamilyIsAMDTurionIIDualMobileM 58: deviceFamilyIsAMDAthlonIIDualMobileM 59: deviceFamilyIsAMDOpteron6100 60: deviceFamilyIsAMDOpteron4100 61: deviceFamilyIsAMDOpteron6200 62: deviceFamilyIsAMDOpteron4200 64: deviceFamilyIsMIPS 65: deviceFamilyIsMIPSR4000 66: deviceFamilyIsMIPSR4200 67: deviceFamilyIsMIPSR4400 68: deviceFamilyIsMIPSR4600 69: deviceFamilyIsMIPSR10000 80: deviceFamilyIsSPARC 81: deviceFamilyIsSuperSPARC 82: deviceFamilyIsmicroSPARCII 83: deviceFamilyIsmicroSPARCIIep 84: deviceFamilyIsUltraSPARC 85: deviceFamilyIsUltraSPARCII 86: deviceFamilyIsUltraSPARCIIi 87: deviceFamilyIsUltraSPARCIII 88: deviceFamilyIsUltraSPARCIIIi 96: deviceFamilyIs68040 97: deviceFamilyIs68xxx 98: deviceFamilyIs68000 99: deviceFamilyIs68010 100: deviceFamilyIs68020 101: deviceFamilyIs68030 107: deviceFamilyIsAMDZen 112: deviceFamilyIsHobbit 120: deviceFamilyIsCrusoeTM5000 121: deviceFamilyIsCrusoeTM3000 122: deviceFamilyIsEfficeonTM8000 128: deviceFamilyIsWeitek 130: deviceFamilyIsIntelCeleronM 131: deviceFamilyIsAMDAthlon64 132: deviceFamilyIsAMDOpteron 133: deviceFamilyIsAMDSempron 134: deviceFamilyIsAMDTurion64Mobile 135: deviceFamilyIsDualCoreAMDOpteron 136: deviceFamilyIsAMDAthlon64X2DualCore 137: deviceFamilyIsAMDTurion64X2Mobile 138: deviceFamilyIsQuadCoreAMDOpteron 139: deviceFamilyIsThirdGenerationAMDOpteron 140: deviceFamilyIsAMDPhenomFXQuadCore 141: deviceFamilyIsAMDPhenomX4QuadCore 142: deviceFamilyIsAMDPhenomX2DualCore 143: deviceFamilyIsAMDAthlonX2DualCore 144: deviceFamilyIsPARISC 145: deviceFamilyIsPARISC8500 146: deviceFamilyIsPARISC8000 147: deviceFamilyIsPARISC7300LC 148: deviceFamilyIsPARISC7200 149: deviceFamilyIsPARISC7100LC 150: deviceFamilyIsPARISC7100 160: deviceFamilyIsV30 161: deviceFamilyIsQuadCoreIntelXeon3200 162: deviceFamilyIsDualCoreIntelXeon3000 163: deviceFamilyIsQuadCoreIntelXeon5300 164: deviceFamilyIsDualCoreIntelXeon5100 165: deviceFamilyIsDualCoreIntelXeon5000 166: deviceFamilyIsDualCoreIntelXeonLV 167: deviceFamilyIsDualCoreIntelXeonULV 168: deviceFamilyIsDualCoreIntelXeon7100 169: deviceFamilyIsQuadCoreIntelXeon5400 170: deviceFamilyIsQuadCoreIntelXeon 171: deviceFamilyIsDualCoreIntelXeon5200 172: deviceFamilyIsDualCoreIntelXeon7200 173: deviceFamilyIsQuadCoreIntelXeon7300 174: deviceFamilyIsQuadCoreIntelXeon7400 175: deviceFamilyIsMultiCoreIntelXeon7400 176: deviceFamilyIsM1 177: deviceFamilyIsM2 179: deviceFamilyIsIntelPentium4HT 180: deviceFamilyIsAS400 182: deviceFamilyIsAMDAthlonXP 183: deviceFamilyIsAMDAthlonMP 184: deviceFamilyIsAMDDuron 185: deviceFamilyIsIntelPentiumM 186: deviceFamilyIsIntelCeleronD 187: deviceFamilyIsIntelPentiumD 188: deviceFamilyIsIntelPentiumExtreme 189: deviceFamilyIsIntelCoreSolo 190: deviceFamilyIsIntelCore2 191: deviceFamilyIsIntelCore2Duo 192: deviceFamilyIsIntelCore2Solo 193: deviceFamilyIsIntelCore2Extreme 194: deviceFamilyIsIntelCore2Quad 195: deviceFamilyIsIntelCore2ExtremeMobile 196: deviceFamilyIsIntelCore2DuoMobile 197: deviceFamilyIsIntelCore2SoloMobile 198: deviceFamilyIsIntelCorei7 199: deviceFamilyIsDualCoreIntelCeleron 200: deviceFamilyIsIBM390 201: deviceFamilyIsG4 202: deviceFamilyIsG5 203: deviceFamilyIsESA390G6 204: deviceFamilyIszArchitectur 205: deviceFamilyIsIntelCorei5 206: deviceFamilyIsIntelCorei3 210: deviceFamilyIsVIAC7M 211: deviceFamilyIsVIAC7D 212: deviceFamilyIsVIAC7 213: deviceFamilyIsVIAEden 214: deviceFamilyIsMultiCoreIntelXeon 215: deviceFamilyIsDualCoreIntelXeon3xxx 216: deviceFamilyIsQuadCoreIntelXeon3xxx 217: deviceFamilyIsVIANano 218: deviceFamilyIsDualCoreIntelXeon5xxx 219: deviceFamilyIsQuadCoreIntelXeon5xxx 221: deviceFamilyIsDualCoreIntelXeon7xxx 222: deviceFamilyIsQuadCoreIntelXeon7xxx 223: deviceFamilyIsMultiCoreIntelXeon7xxx 224: deviceFamilyIsMultiCoreIntelXeon3400 230: deviceFamilyIsEmbeddedAMDOpertonQuadCore 231: deviceFamilyIsAMDPhenomTripleCore 232: deviceFamilyIsAMDTurionUltraDualCoreMobile 233: deviceFamilyIsAMDTurionDualCoreMobile 234: deviceFamilyIsAMDAthlonDualCore 235: deviceFamilyIsAMDSempronSI 236: deviceFamilyIsAMDPhenomII 237: deviceFamilyIsAMDAthlonII 238: deviceFamilyIsSixCoreAMDOpteron 239: deviceFamilyIsAMDSempronM 250: deviceFamilyIsi860 251: deviceFamilyIsi960 - name: processorDeviceMaximumSpeed oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11 type: gauge help: 1100.0030.0001.0011 This attribute defines the maximum speed of the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceCurrentSpeed oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12 type: gauge help: 1100.0030.0001.0012 This attribute defines the current speed of the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceExternalClockSpeed oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13 type: gauge help: 1100.0030.0001.0013 This attribute defines the speed of the external clock for the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceVoltage oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14 type: gauge help: 1100.0030.0001.0014 This attribute defines the voltage powering the processor device in millivolts - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceVersionName oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16 type: OctetString help: 1100.0030.0001.0016 This attribute defines the version of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceCoreCount oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17 type: gauge help: 1100.0030.0001.0017 This attribute defines the number of processor cores detected for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceCoreEnabledCount oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18 type: gauge help: 1100.0030.0001.0018 This attribute defines the number of processor cores enabled for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceThreadCount oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19 type: gauge help: 1100.0030.0001.0019 This attribute defines the number of processor threads detected for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceCharacteristics oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20 type: gauge help: 1100.0030.0001.0020 This attribute defines characteristics of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceExtendedCapabilities oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21 type: gauge help: 1100.0030.0001.0021 This attribute defines extended capabilities of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceExtendedSettings oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22 type: gauge help: 1100.0030.0001.0022 This attribute defines extended settings of the processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceBrandName oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23 type: OctetString help: 1100.0030.0001.0023 This attribute defines the brand of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: processorDeviceFQDD oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 type: OctetString help: 1100.0030.0001.0026 Fully qualified device descriptor (FQDD) of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 indexes: - labelname: processorDevicechassisIndex type: gauge - labelname: processorDeviceIndex type: gauge - name: memoryDeviceSize oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14 type: gauge help: 1100.0050.0001.0014 This attribute defines the size in KBytes of the memory device - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14 indexes: - labelname: memoryDevicechassisIndex type: gauge - labelname: memoryDeviceIndex type: gauge - name: systemStatechassisIndex oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.1 type: gauge help: 0200.0010.0001.0001 This attribute defines the index (one based) of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.1 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateGlobalSystemStatus oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.2 type: gauge help: 0200.0010.0001.0002 This attribute defines the global system status of all system chassis being monitored by the systems management software. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.2 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateChassisState oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.3 type: gauge help: 0200.0010.0001.0003 This attribute defines the state settings of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.3 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: unknown 2: enabled 4: notReady 6: enabledAndNotReady - name: systemStateChassisStatus oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.4 type: gauge help: 0200.0010.0001.0004 This attribute defines the status of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.4 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStatePowerUnitStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.5 type: OctetString help: 0200.0010.0001.0005 This attribute lists the state settings of each power unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.5 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStatePowerUnitStatusRedundancy oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.6 type: gauge help: 0200.0010.0001.0006 This attribute defines the combined redundancy status of all power units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.6 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: full 4: degraded 5: lost 6: notRedundant 7: redundancyOffline - name: systemStatePowerUnitStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.7 type: OctetString help: 0200.0010.0001.0007 This attribute lists the redundancy status of each power unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.7 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStatePowerSupplyStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.8 type: OctetString help: 0200.0010.0001.0008 This attribute lists the state settings of each power supply of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.8 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStatePowerSupplyStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.9 type: gauge help: 0200.0010.0001.0009 This attribute defines the combined status of all power supplies of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.9 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStatePowerSupplyStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.10 type: OctetString help: 0200.0010.0001.0010 This attribute lists the status of each power supply of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.10 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateVoltageStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.11 type: OctetString help: 0200.0010.0001.0011 This attribute lists the state settings of each voltage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.11 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateVoltageStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.12 type: gauge help: 0200.0010.0001.0012 This attribute defines the combined status of all voltage probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.12 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateVoltageStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.13 type: OctetString help: 0200.0010.0001.0013 This attribute lists the status of each voltage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.13 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateAmperageStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.14 type: OctetString help: 0200.0010.0001.0014 This attribute lists the state settings of each amperage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.14 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateAmperageStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.15 type: gauge help: 0200.0010.0001.0015 This attribute defines the combined status of all amperage probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.15 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateAmperageStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.16 type: OctetString help: 0200.0010.0001.0016 This attribute lists the status of each amperage probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.16 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingUnitStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.17 type: OctetString help: 0200.0010.0001.0017 This attribute lists the state settings of each cooling unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.17 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingUnitStatusRedundancy oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.18 type: gauge help: 0200.0010.0001.0018 This attribute defines the combined redundancy status of all cooling units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.18 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: full 4: degraded 5: lost 6: notRedundant 7: redundancyOffline - name: systemStateCoolingUnitStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.19 type: OctetString help: 0200.0010.0001.0019 This attribute lists the redundancy status of each cooling unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.19 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingDeviceStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.20 type: OctetString help: 0200.0010.0001.0020 This attribute lists the state settings of each cooling device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.20 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.21 type: gauge help: 0200.0010.0001.0021 This attribute defines the combined status of all cooling devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.21 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateCoolingDeviceStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.22 type: OctetString help: 0200.0010.0001.0022 This attribute lists the status of each cooling device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.22 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateTemperatureStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.23 type: OctetString help: 0200.0010.0001.0023 This attribute lists the state settings of each temperature probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.23 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateTemperatureStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.24 type: gauge help: 0200.0010.0001.0024 This attribute defines the combined status of all temperature probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.24 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateTemperatureStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.25 type: OctetString help: 0200.0010.0001.0025 This attribute lists the status of each temperature probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.25 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateMemoryDeviceStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.26 type: OctetString help: 0200.0010.0001.0026 This attribute lists the state settings of each memory device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.26 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateMemoryDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.27 type: gauge help: 0200.0010.0001.0027 This attribute defines the combined status of all memory devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.27 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateMemoryDeviceStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.28 type: OctetString help: 0200.0010.0001.0028 This attribute lists the status of each memory device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.28 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateChassisIntrusionStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.29 type: OctetString help: 0200.0010.0001.0029 This attribute lists the state settings of each intrusion detection device of this system chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.29 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateChassisIntrusionStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.30 type: gauge help: 0200.0010.0001.0030 This attribute defines the combined status of all intrusion detection devices of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.30 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateChassisIntrusionStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.31 type: OctetString help: 0200.0010.0001.0031 This attribute lists the status of each intrusion detection device of this system chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.31 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStatePowerUnitStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.42 type: gauge help: 0200.0010.0001.0042 This attribute defines the combined status of all power units of this chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.42 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStatePowerUnitStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.43 type: OctetString help: 0200.0010.0001.0043 This attribute lists the status of each power unit of this chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.43 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCoolingUnitStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.44 type: gauge help: 0200.0010.0001.0044 This attribute defines the combined status of all cooling units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.44 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateCoolingUnitStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.45 type: OctetString help: 0200.0010.0001.0045 This attribute lists the status of each cooling unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.45 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateProcessorDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.50 type: gauge help: 0200.0010.0001.0050 This attribute defines the combined status of all processor devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.50 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateProcessorDeviceStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.51 type: OctetString help: 0200.0010.0001.0051 This attribute lists the status of each processor device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.51 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateBatteryStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.52 type: gauge help: 0200.0010.0001.0052 This attribute defines the combined status of all batteries of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.52 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateBatteryStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.53 type: OctetString help: 0200.0010.0001.0053 This attribute lists the status of each battery of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.53 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateSDCardUnitStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.54 type: gauge help: 0200.0010.0001.0054 This attribute defines the combined status of all SD Card units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.54 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateSDCardUnitStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.55 type: OctetString help: 0200.0010.0001.0055 This attribute lists the status of each SD Card unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.55 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateSDCardDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.56 type: gauge help: 0200.0010.0001.0056 This attribute defines the combined status of all SD Card devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.56 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateSDCardDeviceStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.57 type: OctetString help: 0200.0010.0001.0057 This attribute lists the status of each SD Card device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.57 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateIDSDMCardUnitStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.58 type: gauge help: 0200.0010.0001.0058 This attribute defines the combined status of all IDSDM Card units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.58 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateIDSDMCardUnitStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.59 type: OctetString help: 0200.0010.0001.0059 This attribute lists the status of each IDSDM Card unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.59 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateIDSDMCardDeviceStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.60 type: gauge help: 0200.0010.0001.0060 This attribute defines the combined status of all IDSDM Card devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.60 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateIDSDMCardDeviceStatusList oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.61 type: OctetString help: 0200.0010.0001.0061 This attribute lists the status of each IDSDM Card device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.61 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateTemperatureStatisticsStateDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.62 type: OctetString help: 0200.0010.0001.0062 This attribute lists the state settings of each temperature statistics object of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.62 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateTemperatureStatisticsStatusCombined oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.63 type: gauge help: 0200.0010.0001.0063 This attribute defines the combined status of all temperature statistics objects of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.63 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemStateTemperatureStatisticsStatusDetails oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.64 type: OctetString help: 0200.0010.0001.0064 This attribute lists the status of each temperature statistics object of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.64 indexes: - labelname: systemStatechassisIndex type: gauge - name: systemStateCMCStatus oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.65 type: gauge help: 0200.0010.0001.0065 This attribute defines the status of CMC. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.65 indexes: - labelname: systemStatechassisIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: systemBIOSStatus oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5 type: gauge help: 0300.0050.0001.0005 This attribute defines the status of the system BIOS. - 1.3.6.1.4.1.674.10892.5.4.300.50.1.5 indexes: - labelname: systemBIOSchassisIndex type: gauge - labelname: systemBIOSIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: powerSupplychassisIndex oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.1 type: gauge help: 0600.0012.0001.0001 This attribute defines the index (one based) of the system chassis. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.1 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyIndex oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.2 type: gauge help: 0600.0012.0001.0002 This attribute defines the index (one based) of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.2 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyStateCapabilitiesUnique oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.3 type: gauge help: 0600.0012.0001.0003 This attribute defines the state capabilities of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.3 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: unknown 2: onlineCapable 4: notReadyCapable - name: powerSupplyStateSettingsUnique oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.4 type: gauge help: 0600.0012.0001.0004 This attribute defines the state settings of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.4 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: unknown 2: onLine 4: notReady 8: fanFailure 10: onlineAndFanFailure 16: powerSupplyIsON 32: powerSupplyIsOK 64: acSwitchIsON 66: onlineandAcSwitchIsON 128: acPowerIsON 130: onlineAndAcPowerIsON 210: onlineAndPredictiveFailure 242: acPowerAndSwitchAreOnPowerSupplyIsOnIsOkAndOnline - name: powerSupplyStatus oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.5 type: gauge help: 0600.0012.0001.0005 This attribute defines the status of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.5 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: powerSupplyOutputWatts oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.6 type: gauge help: 0600.0012.0001.0006 This attribute defines the maximum sustained output wattage of the power supply (in tenths of Watts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.6 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyType oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.7 type: gauge help: 0600.0012.0001.0007 This attribute defines the type of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.7 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: powerSupplyTypeIsOther 2: powerSupplyTypeIsUnknown 3: powerSupplyTypeIsLinear 4: powerSupplyTypeIsSwitching 5: powerSupplyTypeIsBattery 6: powerSupplyTypeIsUPS 7: powerSupplyTypeIsConverter 8: powerSupplyTypeIsRegulator 9: powerSupplyTypeIsAC 10: powerSupplyTypeIsDC 11: powerSupplyTypeIsVRM - name: powerSupplyLocationName oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 type: OctetString help: 0600.0012.0001.0008 This attribute defines the location of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyMaximumInputVoltage oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.9 type: gauge help: 0600.0012.0001.0009 This attribute defines the maximum input voltage of the power supply (in Volts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.9 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplypowerUnitIndexReference oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.10 type: gauge help: 0600.0012.0001.0010 This attribute defines the index to the associated power unit if the power supply is part of a power unit. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.10 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplySensorState oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.11 type: gauge help: 0600.0012.0001.0011 This attribute defines the state reported by the power supply sensor - 1.3.6.1.4.1.674.10892.5.4.600.12.1.11 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: presenceDetected 2: psFailureDetected 4: predictiveFailure 8: psACLost 16: acLostOrOutOfRange 32: acOutOfRangeButPresent 64: configurationError - name: powerSupplyConfigurationErrorType oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.12 type: gauge help: 0600.0012.0001.0012 This attribute defines the type of configuration error reported by the power supply sensor - 1.3.6.1.4.1.674.10892.5.4.600.12.1.12 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge enum_values: 1: vendorMismatch 2: revisionMismatch 3: processorMissing - name: powerSupplyPowerMonitorCapable oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.13 type: gauge help: 0600.0012.0001.0013 This attribute defines a boolean value that reports whether the power supply is capable of monitoring power consumption. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.13 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyRatedInputWattage oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.14 type: gauge help: 0600.0012.0001.0014 This attribute defines the rated input wattage of the power supply (in tenths of Watts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.14 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyFQDD oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.15 type: OctetString help: 0600.0012.0001.0015 Fully qualified device descriptor (FQDD) of the power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.15 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: powerSupplyCurrentInputVoltage oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.16 type: gauge help: 0600.0012.0001.0016 This attribute defines the current input voltage to the power supply (in Volts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.16 indexes: - labelname: powerSupplychassisIndex type: gauge - labelname: powerSupplyIndex type: gauge - name: amperageProbeReading oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6 type: gauge help: 0600.0030.0001.0006 This attribute defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.600.30.1.6 indexes: - labelname: amperageProbechassisIndex type: gauge - labelname: amperageProbeIndex type: gauge - name: temperatureProbechassisIndex oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.1 type: gauge help: 0700.0020.0001.0001 This attribute defines the index (one based) of the associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.1 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeIndex oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.2 type: gauge help: 0700.0020.0001.0002 This attribute defines the index (one based) of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.2 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeStateCapabilities oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.3 type: gauge help: 0700.0020.0001.0003 This attribute defines the state capabilities of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.3 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: unknownCapabilities 2: enableCapable 4: notReadyCapable 6: enableAndNotReadyCapable - name: temperatureProbeStateSettings oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.4 type: gauge help: 0700.0020.0001.0004 This attribute defines the state settings of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.4 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: unknown 2: enabled 4: notReady 6: enabledAndNotReady - name: temperatureProbeStatus oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5 type: gauge help: 0700.0020.0001.0005 This attribute defines the probe status of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.5 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCriticalUpper 5: criticalUpper 6: nonRecoverableUpper 7: nonCriticalLower 8: criticalLower 9: nonRecoverableLower 10: failed - name: temperatureProbeReading oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.6 type: gauge help: 0700.0020.0001.0006 This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.20.1.6 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeType oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.7 type: gauge help: 0700.0020.0001.0007 This attribute defines the type of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.7 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: temperatureProbeTypeIsOther 2: temperatureProbeTypeIsUnknown 3: temperatureProbeTypeIsAmbientESM 16: temperatureProbeTypeIsDiscrete - name: temperatureProbeLocationName oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.8 type: DisplayString help: 0700.0020.0001.0008 This attribute defines the location name of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.8 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeUpperNonRecoverableThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.9 type: gauge help: 0700.0020.0001.0009 This attribute defines the upper nonrecoverable threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.9 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeUpperCriticalThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.10 type: gauge help: 0700.0020.0001.0010 This attribute defines the upper critical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.10 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeUpperNonCriticalThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.11 type: gauge help: 0700.0020.0001.0011 This attribute defines the upper noncritical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.11 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeLowerNonCriticalThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.12 type: gauge help: 0700.0020.0001.0012 This attribute defines the lower noncritical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.12 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeLowerCriticalThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.13 type: gauge help: 0700.0020.0001.0013 This attribute defines the lower critical threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.13 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeLowerNonRecoverableThreshold oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.14 type: gauge help: 0700.0020.0001.0014 This attribute defines the lower nonrecoverable threshold of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.14 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge - name: temperatureProbeProbeCapabilities oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.15 type: gauge help: 0700.0020.0001.0015 This attribute defines the probe capabilities of the temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.15 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: upperNonCriticalThresholdSetCapable 2: lowerNonCriticalThresholdSetCapable 4: upperNonCriticalThresholdDefaultCapable 8: lowerNonCriticalThresholdDefaultCapable - name: temperatureProbeDiscreteReading oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.16 type: gauge help: 0700.0020.0001.0016 This attribute defines the reading for a temperature probe of type temperatureProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.20.1.16 indexes: - labelname: temperatureProbechassisIndex type: gauge - labelname: temperatureProbeIndex type: gauge enum_values: 1: temperatureIsGood 2: temperatureIsBad - name: physicalDiskCapacityInMB oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11 type: gauge help: The size of the physical disk in megabytes. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11 indexes: - labelname: physicalDiskNumber type: gauge - name: physicalDiskComponentStatus oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 type: gauge help: The status of the physical disk itself without the propagation of any contained component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24 indexes: - labelname: physicalDiskNumber type: gauge enum_values: 1: other 2: unknown 3: ok 4: nonCritical 5: critical 6: nonRecoverable - name: physicalDiskDisplayName oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55 type: DisplayString help: The physical disk's friendly FQDD as represented in Storage Management. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55 indexes: - labelname: physicalDiskNumber type: gauge - name: physicalDiskProductID oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6 type: DisplayString help: The model number of the physical disk. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6 indexes: - labelname: physicalDiskNumber type: gauge - name: physicalDiskSerialNo oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 type: DisplayString help: The physical disk's unique identification number from the manufacturer. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 indexes: - labelname: physicalDiskNumber type: gauge hpe: walk: - 1.3.6.1.4.1.232.1.2.2.1.1 - 1.3.6.1.4.1.232.11 - 1.3.6.1.4.1.232.14 - 1.3.6.1.4.1.232.3.2.2.1 - 1.3.6.1.4.1.232.3.2.3.1.1 - 1.3.6.1.4.1.232.3.2.5.1.1 - 1.3.6.1.4.1.232.5 - 1.3.6.1.4.1.232.6.2.14.13.1.6 - 1.3.6.1.4.1.232.6.2.15 - 1.3.6.1.4.1.232.6.2.16 - 1.3.6.1.4.1.232.6.2.17 - 1.3.6.1.4.1.232.6.2.6.8.1 - 1.3.6.1.4.1.232.6.2.9 - 1.3.6.1.4.1.232.9.2.2 get: - 1.3.6.1.2.1.1.3.0 metrics: - name: sysUpTime oid: 1.3.6.1.2.1.1.3 type: gauge help: The time (in hundredths of a second) since the network management portion of the system was last re-initialized. - 1.3.6.1.2.1.1.3 - name: cpqSeCpuUnitIndex oid: 1.3.6.1.4.1.232.1.2.2.1.1.1 type: gauge help: This is a number that uniquely specifies a processor unit - 1.3.6.1.4.1.232.1.2.2.1.1.1 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuSlot oid: 1.3.6.1.4.1.232.1.2.2.1.1.2 type: gauge help: This value represents this processor`s slot - 1.3.6.1.4.1.232.1.2.2.1.1.2 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuName oid: 1.3.6.1.4.1.232.1.2.2.1.1.3 type: DisplayString help: The name of this processor - 1.3.6.1.4.1.232.1.2.2.1.1.3 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuSpeed oid: 1.3.6.1.4.1.232.1.2.2.1.1.4 type: gauge help: The current internal speed of this processor in megahertz - 1.3.6.1.4.1.232.1.2.2.1.1.4 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuStep oid: 1.3.6.1.4.1.232.1.2.2.1.1.5 type: gauge help: This step of the processor - 1.3.6.1.4.1.232.1.2.2.1.1.5 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuStatus oid: 1.3.6.1.4.1.232.1.2.2.1.1.6 type: gauge help: The status of the processor - 1.3.6.1.4.1.232.1.2.2.1.1.6 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: ok 3: degraded 4: failed 5: disabled - name: cpqSeCpuExtSpeed oid: 1.3.6.1.4.1.232.1.2.2.1.1.7 type: gauge help: This is the external frequency in megahertz of the processor bus - 1.3.6.1.4.1.232.1.2.2.1.1.7 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuDesigner oid: 1.3.6.1.4.1.232.1.2.2.1.1.8 type: gauge help: This attribute specifies the manufacturer which designs this CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.8 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: intel 3: amd 4: cyrix 5: ti 6: nexgen 7: compaq 8: samsung 9: mitsubishi 10: mips - name: cpqSeCpuSocketNumber oid: 1.3.6.1.4.1.232.1.2.2.1.1.9 type: gauge help: The physical socket number of the CPU chip - 1.3.6.1.4.1.232.1.2.2.1.1.9 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuThreshPassed oid: 1.3.6.1.4.1.232.1.2.2.1.1.10 type: gauge help: CPU threshold passed (Exceeded) - 1.3.6.1.4.1.232.1.2.2.1.1.10 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unsupported 2: "false" 3: "true" - name: cpqSeCpuHwLocation oid: 1.3.6.1.4.1.232.1.2.2.1.1.11 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the CPU - 1.3.6.1.4.1.232.1.2.2.1.1.11 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuCellTablePtr oid: 1.3.6.1.4.1.232.1.2.2.1.1.12 type: gauge help: This is the index for the cell in cpqSeCellTable where this CPU is physically located. - 1.3.6.1.4.1.232.1.2.2.1.1.12 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuPowerpodStatus oid: 1.3.6.1.4.1.232.1.2.2.1.1.13 type: gauge help: This is the status of CPU power pod - 1.3.6.1.4.1.232.1.2.2.1.1.13 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: notfailed 2: failed - name: cpqSeCpuArchitectureRevision oid: 1.3.6.1.4.1.232.1.2.2.1.1.14 type: DisplayString help: This is the CPU architecture revision. - 1.3.6.1.4.1.232.1.2.2.1.1.14 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuCore oid: 1.3.6.1.4.1.232.1.2.2.1.1.15 type: gauge help: The number of cores in this CPU module - 1.3.6.1.4.1.232.1.2.2.1.1.15 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUSerialNumber oid: 1.3.6.1.4.1.232.1.2.2.1.1.16 type: DisplayString help: The OEM serial number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.16 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUPartNumber oid: 1.3.6.1.4.1.232.1.2.2.1.1.17 type: DisplayString help: The OEM part number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.17 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUSerialNumberMfgr oid: 1.3.6.1.4.1.232.1.2.2.1.1.18 type: DisplayString help: The manufacturer serial number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.18 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUPartNumberMfgr oid: 1.3.6.1.4.1.232.1.2.2.1.1.19 type: DisplayString help: The manufacturer part number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.19 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUCoreIndex oid: 1.3.6.1.4.1.232.1.2.2.1.1.20 type: gauge help: This is a number that uniquely identifies a core in a CPU unit. - 1.3.6.1.4.1.232.1.2.2.1.1.20 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUMaxSpeed oid: 1.3.6.1.4.1.232.1.2.2.1.1.21 type: gauge help: This is the maximum internal speed in megahertz this processor can support - 1.3.6.1.4.1.232.1.2.2.1.1.21 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUCoreThreadIndex oid: 1.3.6.1.4.1.232.1.2.2.1.1.22 type: gauge help: This is an unique number to identify the running threads in a CPU core. - 1.3.6.1.4.1.232.1.2.2.1.1.22 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUChipGenerationName oid: 1.3.6.1.4.1.232.1.2.2.1.1.23 type: DisplayString help: CPU chip generation name e.g - 1.3.6.1.4.1.232.1.2.2.1.1.23 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUMultiThreadStatus oid: 1.3.6.1.4.1.232.1.2.2.1.1.24 type: gauge help: This OID identifies whether the CPU threading is enabled or not. - 1.3.6.1.4.1.232.1.2.2.1.1.24 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: enabled 3: disabled - name: cpqSeCPUCoreMaxThreads oid: 1.3.6.1.4.1.232.1.2.2.1.1.25 type: gauge help: This OID indicates the maximum number of threads that a cpu core is capable of. - 1.3.6.1.4.1.232.1.2.2.1.1.25 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuLowPowerStatus oid: 1.3.6.1.4.1.232.1.2.2.1.1.26 type: gauge help: Servers like Itanium has capability to lower power supply to CPU if it is idle for specified period of time - 1.3.6.1.4.1.232.1.2.2.1.1.26 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: lowpowered 3: normalpowered 4: highpowered - name: cpqSeCpuPrimary oid: 1.3.6.1.4.1.232.1.2.2.1.1.27 type: gauge help: On SMP systems one of the CPU is set to Primary and the other CPUs as secondary - 1.3.6.1.4.1.232.1.2.2.1.1.27 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: "false" 3: "true" - name: cpqSeCpuCoreSteppingText oid: 1.3.6.1.4.1.232.1.2.2.1.1.28 type: DisplayString help: The processor stepping version string - 1.3.6.1.4.1.232.1.2.2.1.1.28 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuCurrentPerformanceState oid: 1.3.6.1.4.1.232.1.2.2.1.1.29 type: gauge help: This OID returns the current performance state of this processor - 1.3.6.1.4.1.232.1.2.2.1.1.29 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuMinPerformanceState oid: 1.3.6.1.4.1.232.1.2.2.1.1.30 type: gauge help: This OID returns the minimum performance state set for this processor - 1.3.6.1.4.1.232.1.2.2.1.1.30 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuMaxPerformanceState oid: 1.3.6.1.4.1.232.1.2.2.1.1.31 type: gauge help: This OID returns the maximum performance state set for this processor - 1.3.6.1.4.1.232.1.2.2.1.1.31 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqHoMibRevMajor oid: 1.3.6.1.4.1.232.11.1.1 type: gauge help: The Major Revision level of the MIB - 1.3.6.1.4.1.232.11.1.1 - name: cpqHoMibRevMinor oid: 1.3.6.1.4.1.232.11.1.2 type: gauge help: The Minor Revision level of the MIB - 1.3.6.1.4.1.232.11.1.2 - name: cpqHoMibCondition oid: 1.3.6.1.4.1.232.11.1.3 type: gauge help: The overall condition - 1.3.6.1.4.1.232.11.1.3 enum_values: 1: unknown 2: ok 3: degraded 4: failed - name: cpqHoOsCommonPollFreq oid: 1.3.6.1.4.1.232.11.2.1.4.1 type: gauge help: The Insight Agent`s polling frequency - 1.3.6.1.4.1.232.11.2.1.4.1 - name: cpqHoOsCommonModuleIndex oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.1 type: gauge help: A unique index for this module description. - 1.3.6.1.4.1.232.11.2.1.4.2.1.1 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoOsCommonModuleName oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.2 type: DisplayString help: The module name. - 1.3.6.1.4.1.232.11.2.1.4.2.1.2 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoOsCommonModuleVersion oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.3 type: DisplayString help: The module version in XX.YY format - 1.3.6.1.4.1.232.11.2.1.4.2.1.3 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoOsCommonModuleDate oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.4 type: OctetString help: The module date - 1.3.6.1.4.1.232.11.2.1.4.2.1.4 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoOsCommonModulePurpose oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.5 type: DisplayString help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.11.2.1.4.2.1.5 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoName oid: 1.3.6.1.4.1.232.11.2.2.1 type: DisplayString help: The name of the host operating system (OS). - 1.3.6.1.4.1.232.11.2.2.1 - name: cpqHoVersion oid: 1.3.6.1.4.1.232.11.2.2.2 type: DisplayString help: The version of the host OS. - 1.3.6.1.4.1.232.11.2.2.2 - name: cpqHoDesc oid: 1.3.6.1.4.1.232.11.2.2.3 type: DisplayString help: A further description of the host OS. - 1.3.6.1.4.1.232.11.2.2.3 - name: cpqHoOsType oid: 1.3.6.1.4.1.232.11.2.2.4 type: gauge help: Host Operating system enumeration. - 1.3.6.1.4.1.232.11.2.2.4 enum_values: 1: other 2: netware 3: windowsnt 4: sco-unix 5: unixware 6: os-2 7: ms-dos 8: dos-windows 9: windows95 10: windows98 11: open-vms 12: nsk 13: windowsCE 14: linux 15: windows2000 16: tru64UNIX 17: windows2003 18: windows2003-x64 19: solaris 20: windows2003-ia64 21: windows2008 22: windows2008-x64 23: windows2008-ia64 24: vmware-esx 25: vmware-esxi 26: windows2012 27: windows7 28: windows7-x64 29: windows8 30: windows8-x64 31: windows81 32: windows81-x64 33: windowsxp 34: windowsxp-x64 35: windowsvista 36: windowsvista-x64 37: windows2008-r2 38: windows2012-r2 39: rhel 40: rhel-64 41: solaris-64 42: sles 43: sles-64 44: ubuntu 45: ubuntu-64 46: debian 47: debian-64 48: linux-64-bit 49: other-64-bit 50: centos-32bit 51: centos-64bit 52: oracle-linux32 53: oracle-linux64 54: apple-osx 55: windows2016 56: nanoserver 57: windows2019 - name: cpqHoTelnet oid: 1.3.6.1.4.1.232.11.2.2.5 type: gauge help: Telnet on socket 23 is available. - 1.3.6.1.4.1.232.11.2.2.5 enum_values: 1: other 2: available 3: notavailable - name: cpqHoSystemRole oid: 1.3.6.1.4.1.232.11.2.2.6 type: DisplayString help: The system role - 1.3.6.1.4.1.232.11.2.2.6 - name: cpqHoSystemRoleDetail oid: 1.3.6.1.4.1.232.11.2.2.7 type: DisplayString help: The system detailed description - 1.3.6.1.4.1.232.11.2.2.7 - name: cpqHoCrashDumpState oid: 1.3.6.1.4.1.232.11.2.2.8 type: gauge help: Crash dump state - 1.3.6.1.4.1.232.11.2.2.8 enum_values: 1: completememorydump 2: kernelmemorydump 3: smallmemorydump 4: none - name: cpqHoCrashDumpCondition oid: 1.3.6.1.4.1.232.11.2.2.9 type: gauge help: The condition of the Crash dump configuration. - 1.3.6.1.4.1.232.11.2.2.9 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHoCrashDumpMonitoring oid: 1.3.6.1.4.1.232.11.2.2.10 type: gauge help: Enable/disable crash dump monitoring - 1.3.6.1.4.1.232.11.2.2.10 enum_values: 1: enabled 2: disabled - name: cpqHoMaxLogicalCPUSupported oid: 1.3.6.1.4.1.232.11.2.2.11 type: gauge help: Maximum number of logical CPUs supported by Operating System. - 1.3.6.1.4.1.232.11.2.2.11 - name: cpqHoSystemName oid: 1.3.6.1.4.1.232.11.2.2.12 type: DisplayString help: Full computer name of the host - 1.3.6.1.4.1.232.11.2.2.12 - name: cpqHosysDescr oid: 1.3.6.1.4.1.232.11.2.2.13 type: DisplayString help: The value that would be returned in the RFC-1213 sysDescr MIB element - 1.3.6.1.4.1.232.11.2.2.13 - name: cpqHoCpuUtilUnitIndex oid: 1.3.6.1.4.1.232.11.2.3.1.1.1 type: gauge help: This number uniquely specifies a processor unit - 1.3.6.1.4.1.232.11.2.3.1.1.1 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilMin oid: 1.3.6.1.4.1.232.11.2.3.1.1.2 type: gauge help: The CPU utilization as a percentage of the theoretical maximum during the last minute - 1.3.6.1.4.1.232.11.2.3.1.1.2 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilFiveMin oid: 1.3.6.1.4.1.232.11.2.3.1.1.3 type: gauge help: The CPU utilization as a percentage of the theoretical maximum during the last five minutes - 1.3.6.1.4.1.232.11.2.3.1.1.3 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilThirtyMin oid: 1.3.6.1.4.1.232.11.2.3.1.1.4 type: gauge help: The CPU utilization as a percentage of the theoretical maximum during the last thirty minutes - 1.3.6.1.4.1.232.11.2.3.1.1.4 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilHour oid: 1.3.6.1.4.1.232.11.2.3.1.1.5 type: gauge help: The CPU utilization as a percentage of the theoretical maximum during the last hour - 1.3.6.1.4.1.232.11.2.3.1.1.5 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilHwLocation oid: 1.3.6.1.4.1.232.11.2.3.1.1.6 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the CPU - 1.3.6.1.4.1.232.11.2.3.1.1.6 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoFileSysIndex oid: 1.3.6.1.4.1.232.11.2.4.1.1.1 type: gauge help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.4.1.1.1 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysDesc oid: 1.3.6.1.4.1.232.11.2.4.1.1.2 type: DisplayString help: A description of the file system include the GUID. - 1.3.6.1.4.1.232.11.2.4.1.1.2 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysSpaceTotal oid: 1.3.6.1.4.1.232.11.2.4.1.1.3 type: gauge help: The file system size in megabytes - 1.3.6.1.4.1.232.11.2.4.1.1.3 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysSpaceUsed oid: 1.3.6.1.4.1.232.11.2.4.1.1.4 type: gauge help: The megabytes of file system space currently in use - 1.3.6.1.4.1.232.11.2.4.1.1.4 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysPercentSpaceUsed oid: 1.3.6.1.4.1.232.11.2.4.1.1.5 type: gauge help: The percent of file system space currently in use - 1.3.6.1.4.1.232.11.2.4.1.1.5 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysAllocUnitsTotal oid: 1.3.6.1.4.1.232.11.2.4.1.1.6 type: gauge help: The total number of files (directory entries) that can be stored on the file system if a limit exists other than total space used - 1.3.6.1.4.1.232.11.2.4.1.1.6 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysAllocUnitsUsed oid: 1.3.6.1.4.1.232.11.2.4.1.1.7 type: gauge help: The number of files (directory entries) on this file system - 1.3.6.1.4.1.232.11.2.4.1.1.7 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysStatus oid: 1.3.6.1.4.1.232.11.2.4.1.1.8 type: gauge help: The Threshold Status - 1.3.6.1.4.1.232.11.2.4.1.1.8 indexes: - labelname: cpqHoFileSysIndex type: gauge enum_values: 1: unknown 2: ok 3: degraded 4: failed - name: cpqHoFileSysShortDesc oid: 1.3.6.1.4.1.232.11.2.4.1.1.9 type: DisplayString help: A description of the file system. - 1.3.6.1.4.1.232.11.2.4.1.1.9 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysCondition oid: 1.3.6.1.4.1.232.11.2.4.2 type: gauge help: The overall condition of File System Threshold - 1.3.6.1.4.1.232.11.2.4.2 enum_values: 1: unknown 2: ok 3: degraded 4: failed - name: cpqHoIfPhysMapIndex oid: 1.3.6.1.4.1.232.11.2.5.1.1.1 type: gauge help: An index that uniquely specifies this entry - 1.3.6.1.4.1.232.11.2.5.1.1.1 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapSlot oid: 1.3.6.1.4.1.232.11.2.5.1.1.2 type: gauge help: The number of the slot containing the physical hardware that implements this interface - 1.3.6.1.4.1.232.11.2.5.1.1.2 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapIoBaseAddr oid: 1.3.6.1.4.1.232.11.2.5.1.1.3 type: gauge help: The base I/O address of the physical hardware that implements this interface. - 1.3.6.1.4.1.232.11.2.5.1.1.3 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapIrq oid: 1.3.6.1.4.1.232.11.2.5.1.1.4 type: gauge help: The number of the IRQ (interrupt) used for this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.4 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapDma oid: 1.3.6.1.4.1.232.11.2.5.1.1.5 type: gauge help: The number of the DMA channel used for this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.5 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapMemBaseAddr oid: 1.3.6.1.4.1.232.11.2.5.1.1.6 type: gauge help: The base memory address used by this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.6 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapPort oid: 1.3.6.1.4.1.232.11.2.5.1.1.7 type: gauge help: The port number of the interface for multi-port NICs - 1.3.6.1.4.1.232.11.2.5.1.1.7 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapDuplexState oid: 1.3.6.1.4.1.232.11.2.5.1.1.8 type: gauge help: This variable describes the configured duplex state of the NIC. - 1.3.6.1.4.1.232.11.2.5.1.1.8 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge enum_values: 1: other 2: half 3: full - name: cpqHoIfPhysMapCondition oid: 1.3.6.1.4.1.232.11.2.5.1.1.9 type: gauge help: The condition of this interface. - 1.3.6.1.4.1.232.11.2.5.1.1.9 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHoIfPhysMapOverallCondition oid: 1.3.6.1.4.1.232.11.2.5.2 type: gauge help: The overall condition of all interfaces. - 1.3.6.1.4.1.232.11.2.5.2 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHoSWRunningIndex oid: 1.3.6.1.4.1.232.11.2.6.1.1.1 type: gauge help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.6.1.1.1 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningName oid: 1.3.6.1.4.1.232.11.2.6.1.1.2 type: DisplayString help: The name of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.2 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningDesc oid: 1.3.6.1.4.1.232.11.2.6.1.1.3 type: DisplayString help: A description of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.3 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningVersion oid: 1.3.6.1.4.1.232.11.2.6.1.1.4 type: DisplayString help: The version of the software - 1.3.6.1.4.1.232.11.2.6.1.1.4 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningDate oid: 1.3.6.1.4.1.232.11.2.6.1.1.5 type: OctetString help: The software date - 1.3.6.1.4.1.232.11.2.6.1.1.5 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningMonitor oid: 1.3.6.1.4.1.232.11.2.6.1.1.6 type: gauge help: The user specified monitor option for a process. - 1.3.6.1.4.1.232.11.2.6.1.1.6 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: other 2: start 3: stop 4: startAndStop 5: count 6: startAndCount 7: countAndStop 8: startCountAndStop - name: cpqHoSWRunningState oid: 1.3.6.1.4.1.232.11.2.6.1.1.7 type: gauge help: The current state of monitored process. - 1.3.6.1.4.1.232.11.2.6.1.1.7 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: other 2: started 3: stopped - name: cpqHoSWRunningCount oid: 1.3.6.1.4.1.232.11.2.6.1.1.8 type: gauge help: For each process name, the number of instances of the process running on the system is kept count of, in this variable. - 1.3.6.1.4.1.232.11.2.6.1.1.8 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningCountMin oid: 1.3.6.1.4.1.232.11.2.6.1.1.9 type: gauge help: This is the lower threshold on cpqHoSWRunningCount to be set by the user. - 1.3.6.1.4.1.232.11.2.6.1.1.9 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningCountMax oid: 1.3.6.1.4.1.232.11.2.6.1.1.10 type: gauge help: This is the upper threshold on cpqHoSWRunningCount to be set by the user. - 1.3.6.1.4.1.232.11.2.6.1.1.10 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningEventTime oid: 1.3.6.1.4.1.232.11.2.6.1.1.11 type: OctetString help: The system time at which the monitored event, as per cpqHoSWRunningMonitor, last occurred - 1.3.6.1.4.1.232.11.2.6.1.1.11 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningStatus oid: 1.3.6.1.4.1.232.11.2.6.1.1.12 type: gauge help: The overall alarm state of the resources managed by the software, or the software itself. - 1.3.6.1.4.1.232.11.2.6.1.1.12 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: unknown 2: normal 3: warning 4: minor 5: major 6: critical 7: disabled - name: cpqHoSWRunningConfigStatus oid: 1.3.6.1.4.1.232.11.2.6.1.1.13 type: gauge help: The configuration state of the software - 1.3.6.1.4.1.232.11.2.6.1.1.13 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: unknown 2: starting 3: initialized 4: configured 5: operational - name: cpqHoSWRunningIdentifier oid: 1.3.6.1.4.1.232.11.2.6.1.1.14 type: DisplayString help: The unique identifier of the sofware - 1.3.6.1.4.1.232.11.2.6.1.1.14 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningRedundancyMode oid: 1.3.6.1.4.1.232.11.2.6.1.1.15 type: gauge help: When the software is running in a high availability mode, the failover mode of this instance of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.15 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: unknown 2: master 3: backup 4: slave - name: cpqHoSwRunningTrapDesc oid: 1.3.6.1.4.1.232.11.2.6.2 type: DisplayString help: The error message for a process monitor event. - 1.3.6.1.4.1.232.11.2.6.2 - name: cpqHoSwVerNextIndex oid: 1.3.6.1.4.1.232.11.2.7.1 type: gauge help: The index of the next available entry in the cpqHoSwVer table - 1.3.6.1.4.1.232.11.2.7.1 - name: cpqHoSwVerIndex oid: 1.3.6.1.4.1.232.11.2.7.2.1.1 type: gauge help: An index that uniquely identifies an entry in the cpqHoSwVer table. - 1.3.6.1.4.1.232.11.2.7.2.1.1 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerStatus oid: 1.3.6.1.4.1.232.11.2.7.2.1.2 type: gauge help: Status for the software item. - 1.3.6.1.4.1.232.11.2.7.2.1.2 indexes: - labelname: cpqHoSwVerIndex type: gauge enum_values: 1: other 2: loaded 3: notloaded - name: cpqHoSwVerType oid: 1.3.6.1.4.1.232.11.2.7.2.1.3 type: gauge help: Type of software item. - 1.3.6.1.4.1.232.11.2.7.2.1.3 indexes: - labelname: cpqHoSwVerIndex type: gauge enum_values: 1: other 2: driver 3: agent 4: sysutil 5: application 6: keyfile 7: firmware - name: cpqHoSwVerName oid: 1.3.6.1.4.1.232.11.2.7.2.1.4 type: DisplayString help: The name of this software item. - 1.3.6.1.4.1.232.11.2.7.2.1.4 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerDescription oid: 1.3.6.1.4.1.232.11.2.7.2.1.5 type: DisplayString help: The description of this software item. - 1.3.6.1.4.1.232.11.2.7.2.1.5 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerDate oid: 1.3.6.1.4.1.232.11.2.7.2.1.6 type: OctetString help: The date of the software item, if any - 1.3.6.1.4.1.232.11.2.7.2.1.6 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerLocation oid: 1.3.6.1.4.1.232.11.2.7.2.1.7 type: DisplayString help: The location of this software item on the server. - 1.3.6.1.4.1.232.11.2.7.2.1.7 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerVersion oid: 1.3.6.1.4.1.232.11.2.7.2.1.8 type: DisplayString help: An string that specifies the version of this item. - 1.3.6.1.4.1.232.11.2.7.2.1.8 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerVersionBinary oid: 1.3.6.1.4.1.232.11.2.7.2.1.9 type: DisplayString help: An string that specifies the version of this item based on the binary version resource. - 1.3.6.1.4.1.232.11.2.7.2.1.9 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerAgentsVer oid: 1.3.6.1.4.1.232.11.2.7.3 type: DisplayString help: A string that specifies the version of the Insight Management Agents running on the system. - 1.3.6.1.4.1.232.11.2.7.3 - name: cpqHoGenericData oid: 1.3.6.1.4.1.232.11.2.8.1 type: DisplayString help: Data for the generic trap. - 1.3.6.1.4.1.232.11.2.8.1 - name: cpqHoCriticalSoftwareUpdateData oid: 1.3.6.1.4.1.232.11.2.8.2 type: DisplayString help: Data for the Critical Software Update trap. - 1.3.6.1.4.1.232.11.2.8.2 - name: cpqHoSwPerfAppErrorDesc oid: 1.3.6.1.4.1.232.11.2.9.1 type: DisplayString help: This string holds error information about the last application error that occurred in the system. - 1.3.6.1.4.1.232.11.2.9.1 - name: cpqHoMibStatusArray oid: 1.3.6.1.4.1.232.11.2.10.1 type: OctetString help: The MIB Status Array is an array of MIB status structures - 1.3.6.1.4.1.232.11.2.10.1 - name: cpqHoConfigChangedDate oid: 1.3.6.1.4.1.232.11.2.10.2 type: OctetString help: The date/time when the agents were last loaded - 1.3.6.1.4.1.232.11.2.10.2 - name: cpqHoGUID oid: 1.3.6.1.4.1.232.11.2.10.3 type: OctetString help: The globally unique identifier of this physical server - 1.3.6.1.4.1.232.11.2.10.3 - name: cpqHoCodeServer oid: 1.3.6.1.4.1.232.11.2.10.4 type: gauge help: This item indicates how many code server shares are currently configured on the system - 1.3.6.1.4.1.232.11.2.10.4 - name: cpqHoWebMgmtPort oid: 1.3.6.1.4.1.232.11.2.10.5 type: gauge help: This item indicates the port used by the Insight Web Agent - 1.3.6.1.4.1.232.11.2.10.5 - name: cpqHoGUIDCanonical oid: 1.3.6.1.4.1.232.11.2.10.6 type: OctetString help: The globally unique identifier in canonical format of this physical server - 1.3.6.1.4.1.232.11.2.10.6 - name: cpqHoMibHealthStatusArray oid: 1.3.6.1.4.1.232.11.2.10.7 type: OctetString help: 'The MIB Health Status Array is an array of status values representing an overall status in element 0 follwed by server and storage status values as follows: Octet Element Field ======== ======= ========= 0 0 Aggregated Status of array elements 1 1 Status of element 1 2 2 Status of element 2 - 1.3.6.1.4.1.232.11.2.10.7' - name: cpqHoTrapFlags oid: 1.3.6.1.4.1.232.11.2.11.1 type: gauge help: The Trap Flags - 1.3.6.1.4.1.232.11.2.11.1 - name: cpqHoClientLastModified oid: 1.3.6.1.4.1.232.11.2.12.1 type: OctetString help: The date/time of the last modification to the client table - 1.3.6.1.4.1.232.11.2.12.1 - name: cpqHoClientDelete oid: 1.3.6.1.4.1.232.11.2.12.2 type: DisplayString help: Setting this variable to the name of a client in the client table will cause that row in the table to be deleted - 1.3.6.1.4.1.232.11.2.12.2 - name: cpqHoClientIndex oid: 1.3.6.1.4.1.232.11.2.12.3.1.1 type: gauge help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.12.3.1.1 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientName oid: 1.3.6.1.4.1.232.11.2.12.3.1.2 type: DisplayString help: The Win95 machine name of this client. - 1.3.6.1.4.1.232.11.2.12.3.1.2 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientIpxAddress oid: 1.3.6.1.4.1.232.11.2.12.3.1.3 type: OctetString help: The IPX address for this client, all octets should be set to 0xff if this machine does not support IPX - 1.3.6.1.4.1.232.11.2.12.3.1.3 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientIpAddress oid: 1.3.6.1.4.1.232.11.2.12.3.1.4 type: InetAddressIPv4 help: The IP address for this client, all octets should be set to 0xff if this machine does not support IP - 1.3.6.1.4.1.232.11.2.12.3.1.4 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientCommunity oid: 1.3.6.1.4.1.232.11.2.12.3.1.5 type: DisplayString help: A community name that can be used to query the client with SNMP - 1.3.6.1.4.1.232.11.2.12.3.1.5 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientID oid: 1.3.6.1.4.1.232.11.2.12.3.1.6 type: OctetString help: The unique identifier of this client. - 1.3.6.1.4.1.232.11.2.12.3.1.6 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoPhysicalMemorySize oid: 1.3.6.1.4.1.232.11.2.13.1 type: gauge help: Total amount of physical memory as seen by the OS (in megabytes) - 1.3.6.1.4.1.232.11.2.13.1 - name: cpqHoPhysicalMemoryFree oid: 1.3.6.1.4.1.232.11.2.13.2 type: gauge help: The amount of free physical memory (in megabytes) - 1.3.6.1.4.1.232.11.2.13.2 - name: cpqHoPagingMemorySize oid: 1.3.6.1.4.1.232.11.2.13.3 type: gauge help: Total virtual memory available from the OS (in megabytes) - 1.3.6.1.4.1.232.11.2.13.3 - name: cpqHoPagingMemoryFree oid: 1.3.6.1.4.1.232.11.2.13.4 type: gauge help: Available paging memory (in megabytes) - 1.3.6.1.4.1.232.11.2.13.4 - name: cpqHoBootPagingFileSize oid: 1.3.6.1.4.1.232.11.2.13.5 type: DisplayString help: The paging file size of the boot volume in the format xxxMB or xxxGB, where xxx is the paging file size in that unit shown right after it - 1.3.6.1.4.1.232.11.2.13.5 - name: cpqHoBootPagingFileMinimumSize oid: 1.3.6.1.4.1.232.11.2.13.6 type: DisplayString help: Minimum paging file size of the boot volume required to save the memory dump in the event of a system crash - 1.3.6.1.4.1.232.11.2.13.6 - name: cpqHoBootPagingFileVolumeFreeSpace oid: 1.3.6.1.4.1.232.11.2.13.7 type: DisplayString help: Free space of the boot volume required to save the memory dump in the event of a system crash - 1.3.6.1.4.1.232.11.2.13.7 - name: cpqHoFwVerIndex oid: 1.3.6.1.4.1.232.11.2.14.1.1.1 type: gauge help: Firmware Version Index - 1.3.6.1.4.1.232.11.2.14.1.1.1 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerCategory oid: 1.3.6.1.4.1.232.11.2.14.1.1.2 type: gauge help: Firmware Version Category. - 1.3.6.1.4.1.232.11.2.14.1.1.2 indexes: - labelname: cpqHoFwVerIndex type: gauge enum_values: 1: other 2: storage 3: nic 4: rib 5: system - name: cpqHoFwVerDeviceType oid: 1.3.6.1.4.1.232.11.2.14.1.1.3 type: gauge help: Firmware Version Device Type. - 1.3.6.1.4.1.232.11.2.14.1.1.3 indexes: - labelname: cpqHoFwVerIndex type: gauge enum_values: 1: other 2: internalArrayController 3: fibreArrayController 4: scsiController 5: fibreChannelTapeController 6: modularDataRouter 7: ideCdRomDrive 8: ideDiskDrive 9: scsiCdRom-ScsiAttached 10: scsiDiskDrive-ScsiAttached 11: scsiTapeDrive-ScsiAttached 12: scsiTapeLibrary-ScsiAttached 13: scsiDiskDrive-ArrayAttached 14: scsiTapeDrive-ArrayAttached 15: scsiTapeLibrary-ArrayAttached 16: scsiDiskDrive-FibreAttached 17: scsiTapeDrive-FibreAttached 18: scsiTapeLibrary-FibreAttached 19: scsiEnclosureBackplaneRom-ScsiAttached 20: scsiEnclosureBackplaneRom-ArrayAttached 21: scsiEnclosureBackplaneRom-FibreAttached 22: scsiEnclosureBackplaneRom-ra4x00 23: systemRom 24: networkInterfaceController 25: remoteInsightBoard 26: sasDiskDrive-SasAttached 27: sataDiskDrive-SataAttached 28: usbController 29: sasControllerAdapter 30: sataControllerAdapter 31: systemDevice 32: fibreChannelHba 33: convergedNetworkAdapter 34: ideController - name: cpqHoFwVerDisplayName oid: 1.3.6.1.4.1.232.11.2.14.1.1.4 type: DisplayString help: Firmware Version Device Display Name - 1.3.6.1.4.1.232.11.2.14.1.1.4 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerVersion oid: 1.3.6.1.4.1.232.11.2.14.1.1.5 type: DisplayString help: Firmware Version - 1.3.6.1.4.1.232.11.2.14.1.1.5 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerLocation oid: 1.3.6.1.4.1.232.11.2.14.1.1.6 type: DisplayString help: Firmware Version Device Location - 1.3.6.1.4.1.232.11.2.14.1.1.6 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerXmlString oid: 1.3.6.1.4.1.232.11.2.14.1.1.7 type: DisplayString help: Firmware Version Xml String - 1.3.6.1.4.1.232.11.2.14.1.1.7 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerKeyString oid: 1.3.6.1.4.1.232.11.2.14.1.1.8 type: DisplayString help: Firmware Version Key String - 1.3.6.1.4.1.232.11.2.14.1.1.8 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerUpdateMethod oid: 1.3.6.1.4.1.232.11.2.14.1.1.9 type: gauge help: Firmware Version update method. - 1.3.6.1.4.1.232.11.2.14.1.1.9 indexes: - labelname: cpqHoFwVerIndex type: gauge enum_values: 1: other 2: noUpdate 3: softwareflash 4: replacePhysicalRom - name: cpqHoHWInfoPlatform oid: 1.3.6.1.4.1.232.11.2.15.1 type: gauge help: Hardware platform type - 1.3.6.1.4.1.232.11.2.15.1 enum_values: 1: unknown 2: cellular 3: foundation 4: virtualMachine 5: serverBlade - name: cpqPwrWarnType oid: 1.3.6.1.4.1.232.11.2.16.1 type: DisplayString help: Type of power reading on which the warning is based. - 1.3.6.1.4.1.232.11.2.16.1 - name: cpqPwrWarnThreshold oid: 1.3.6.1.4.1.232.11.2.16.2 type: gauge help: The threshold the power usage must exceed (in Watts). - 1.3.6.1.4.1.232.11.2.16.2 - name: cpqPwrWarnDuration oid: 1.3.6.1.4.1.232.11.2.16.3 type: gauge help: Duration that power usage must be exceeded before warning (in minutes). - 1.3.6.1.4.1.232.11.2.16.3 - name: cpqSerialNum oid: 1.3.6.1.4.1.232.11.2.16.4 type: DisplayString help: Serial number of the server. - 1.3.6.1.4.1.232.11.2.16.4 - name: cpqServerUUID oid: 1.3.6.1.4.1.232.11.2.16.5 type: DisplayString help: Server UUID - 1.3.6.1.4.1.232.11.2.16.5 - name: cpqIdeMibRevMajor oid: 1.3.6.1.4.1.232.14.1.1 type: gauge help: The Major Revision level - 1.3.6.1.4.1.232.14.1.1 - name: cpqIdeMibRevMinor oid: 1.3.6.1.4.1.232.14.1.2 type: gauge help: The Minor Revision level - 1.3.6.1.4.1.232.14.1.2 - name: cpqIdeMibCondition oid: 1.3.6.1.4.1.232.14.1.3 type: gauge help: The overall condition - 1.3.6.1.4.1.232.14.1.3 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeOsCommonPollFreq oid: 1.3.6.1.4.1.232.14.2.1.4.1 type: gauge help: The Insight Agent`s polling frequency - 1.3.6.1.4.1.232.14.2.1.4.1 - name: cpqIdeOsCommonModuleIndex oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.1 type: gauge help: A unique index for this module description. - 1.3.6.1.4.1.232.14.2.1.4.2.1.1 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeOsCommonModuleName oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.2 type: DisplayString help: The module name. - 1.3.6.1.4.1.232.14.2.1.4.2.1.2 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeOsCommonModuleVersion oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.3 type: DisplayString help: The module version in XX.YY format - 1.3.6.1.4.1.232.14.2.1.4.2.1.3 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeOsCommonModuleDate oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.4 type: OctetString help: The module date - 1.3.6.1.4.1.232.14.2.1.4.2.1.4 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeOsCommonModulePurpose oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.5 type: DisplayString help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.14.2.1.4.2.1.5 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeIdentIndex oid: 1.3.6.1.4.1.232.14.2.2.1.1.1 type: gauge help: An index that uniquely specifies each device - 1.3.6.1.4.1.232.14.2.2.1.1.1 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentModel oid: 1.3.6.1.4.1.232.14.2.2.1.1.2 type: DisplayString help: IDE Drive Model - 1.3.6.1.4.1.232.14.2.2.1.1.2 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentSerNum oid: 1.3.6.1.4.1.232.14.2.2.1.1.3 type: DisplayString help: IDE Drive Serial Number - 1.3.6.1.4.1.232.14.2.2.1.1.3 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentFWVers oid: 1.3.6.1.4.1.232.14.2.2.1.1.4 type: DisplayString help: IDE Firmware Version - 1.3.6.1.4.1.232.14.2.2.1.1.4 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentCondition oid: 1.3.6.1.4.1.232.14.2.2.1.1.5 type: gauge help: IDE Drive Condition - 1.3.6.1.4.1.232.14.2.2.1.1.5 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeIdentErrorNumber oid: 1.3.6.1.4.1.232.14.2.2.1.1.6 type: DisplayString help: IDE Error Number - 1.3.6.1.4.1.232.14.2.2.1.1.6 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentType oid: 1.3.6.1.4.1.232.14.2.2.1.1.7 type: gauge help: IDE Device Type - 1.3.6.1.4.1.232.14.2.2.1.1.7 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: disk 3: tape 4: printer 5: processor 6: wormDrive 7: cd-rom 8: scanner 9: optical 10: jukeBox 11: commDev - name: cpqIdeIdentTypeExtended oid: 1.3.6.1.4.1.232.14.2.2.1.1.8 type: gauge help: IDE Extended Device Type - 1.3.6.1.4.1.232.14.2.2.1.1.8 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: pdcd 3: removableDisk - name: cpqIdeIdentCondition2 oid: 1.3.6.1.4.1.232.14.2.2.1.1.9 type: gauge help: IDE Drive Condition - 1.3.6.1.4.1.232.14.2.2.1.1.9 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeIdentStatus oid: 1.3.6.1.4.1.232.14.2.2.1.1.10 type: gauge help: IDE Drive Satus - 1.3.6.1.4.1.232.14.2.2.1.1.10 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: ok 3: preFailureDegraded 4: ultraAtaDegraded - name: cpqIdeIdentUltraAtaAvailability oid: 1.3.6.1.4.1.232.14.2.2.1.1.11 type: gauge help: This describes the availability of Ultra ATA transfers between this device and the controller - 1.3.6.1.4.1.232.14.2.2.1.1.11 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: noNotSupportedByDeviceAndController 3: noNotSupportedByDevice 4: noNotSupportedByController 5: noDisabledInSetup 6: yesEnabledInSetup - name: cpqIdeControllerIndex oid: 1.3.6.1.4.1.232.14.2.3.1.1.1 type: gauge help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.3.1.1.1 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerOverallCondition oid: 1.3.6.1.4.1.232.14.2.3.1.1.2 type: gauge help: IDE Controller Overall Condition - 1.3.6.1.4.1.232.14.2.3.1.1.2 indexes: - labelname: cpqIdeControllerIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeControllerModel oid: 1.3.6.1.4.1.232.14.2.3.1.1.3 type: DisplayString help: IDE Controller Model - 1.3.6.1.4.1.232.14.2.3.1.1.3 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerFwRev oid: 1.3.6.1.4.1.232.14.2.3.1.1.4 type: DisplayString help: IDE Controller Firmware Revision - 1.3.6.1.4.1.232.14.2.3.1.1.4 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerSlot oid: 1.3.6.1.4.1.232.14.2.3.1.1.5 type: gauge help: IDE Controller Slot - 1.3.6.1.4.1.232.14.2.3.1.1.5 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerStatus oid: 1.3.6.1.4.1.232.14.2.3.1.1.6 type: gauge help: IDE Channel Host Controller Status - 1.3.6.1.4.1.232.14.2.3.1.1.6 indexes: - labelname: cpqIdeControllerIndex type: gauge enum_values: 1: other 2: ok 3: failed - name: cpqIdeControllerCondition oid: 1.3.6.1.4.1.232.14.2.3.1.1.7 type: gauge help: IDE Controller Condition - 1.3.6.1.4.1.232.14.2.3.1.1.7 indexes: - labelname: cpqIdeControllerIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeControllerSerialNumber oid: 1.3.6.1.4.1.232.14.2.3.1.1.8 type: DisplayString help: IDE Controller Serial Number - 1.3.6.1.4.1.232.14.2.3.1.1.8 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerHwLocation oid: 1.3.6.1.4.1.232.14.2.3.1.1.9 type: DisplayString help: IDE Controller Hardware Location - 1.3.6.1.4.1.232.14.2.3.1.1.9 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerPciLocation oid: 1.3.6.1.4.1.232.14.2.3.1.1.10 type: DisplayString help: IDE Controller PCI Location - 1.3.6.1.4.1.232.14.2.3.1.1.10 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeAtaDiskControllerIndex oid: 1.3.6.1.4.1.232.14.2.4.1.1.1 type: gauge help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.4.1.1.1 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskIndex oid: 1.3.6.1.4.1.232.14.2.4.1.1.2 type: gauge help: An index that uniquely identifies each disk. - 1.3.6.1.4.1.232.14.2.4.1.1.2 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskModel oid: 1.3.6.1.4.1.232.14.2.4.1.1.3 type: DisplayString help: ATA Disk Model - 1.3.6.1.4.1.232.14.2.4.1.1.3 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskFwRev oid: 1.3.6.1.4.1.232.14.2.4.1.1.4 type: DisplayString help: ATA Disk Firmware Revision - 1.3.6.1.4.1.232.14.2.4.1.1.4 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskSerialNumber oid: 1.3.6.1.4.1.232.14.2.4.1.1.5 type: DisplayString help: ATA Disk Serial Number - 1.3.6.1.4.1.232.14.2.4.1.1.5 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskStatus oid: 1.3.6.1.4.1.232.14.2.4.1.1.6 type: gauge help: ATA Disk Status - 1.3.6.1.4.1.232.14.2.4.1.1.6 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: ok 3: smartError 4: failed 5: ssdWearOut - name: cpqIdeAtaDiskCondition oid: 1.3.6.1.4.1.232.14.2.4.1.1.7 type: gauge help: ATA Disk Condition - 1.3.6.1.4.1.232.14.2.4.1.1.7 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeAtaDiskCapacity oid: 1.3.6.1.4.1.232.14.2.4.1.1.8 type: gauge help: ATA Disk Capacity - 1.3.6.1.4.1.232.14.2.4.1.1.8 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskSmartEnabled oid: 1.3.6.1.4.1.232.14.2.4.1.1.9 type: gauge help: ATA Disk S.M.A.R.T Enabled? other(1) The agent cannot determine the state of S.M.A.R.T - 1.3.6.1.4.1.232.14.2.4.1.1.9 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqIdeAtaDiskTransferMode oid: 1.3.6.1.4.1.232.14.2.4.1.1.10 type: gauge help: ATA Disk Transfer Mode - 1.3.6.1.4.1.232.14.2.4.1.1.10 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: pioMode0 3: pioMode1 4: pioMode2 5: pioMode3 6: pioMode4 7: dmaMode0 8: dmaMode1 9: dmaMode2 10: ultraDmaMode0 11: ultraDmaMode1 12: ultraDmaMode2 13: ultraDmaMode3 14: ultraDmaMode4 15: ultraDmaMode5 - name: cpqIdeAtaDiskChannel oid: 1.3.6.1.4.1.232.14.2.4.1.1.11 type: gauge help: ATA Disk Channel - 1.3.6.1.4.1.232.14.2.4.1.1.11 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: channel0 3: channel1 4: serial - name: cpqIdeAtaDiskNumber oid: 1.3.6.1.4.1.232.14.2.4.1.1.12 type: gauge help: ATA Disk Number - 1.3.6.1.4.1.232.14.2.4.1.1.12 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: device0 3: device1 4: sataDevice0 5: sataDevice1 6: sataDevice2 7: sataDevice3 8: sataDevice4 9: sataDevice5 10: sataDevice6 11: sataDevice7 21: bay1 22: bay2 23: bay3 24: bay4 25: bay5 26: bay6 27: bay7 28: bay8 29: bay9 30: bay10 31: bay11 32: bay12 33: bay13 34: bay14 - name: cpqIdeAtaDiskLogicalDriveMember oid: 1.3.6.1.4.1.232.14.2.4.1.1.13 type: gauge help: Logical Drive Membership? other(1) The agent cannot determine if the ATA disk is part of a logical drive - 1.3.6.1.4.1.232.14.2.4.1.1.13 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqIdeAtaDiskIsSpare oid: 1.3.6.1.4.1.232.14.2.4.1.1.14 type: gauge help: ATA Disk Spare? other(1) The agent cannot determine if the ATA disk is a spare - 1.3.6.1.4.1.232.14.2.4.1.1.14 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqIdeAtaDiskOsName oid: 1.3.6.1.4.1.232.14.2.4.1.1.15 type: DisplayString help: ATA Disk OS Name - 1.3.6.1.4.1.232.14.2.4.1.1.15 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskType oid: 1.3.6.1.4.1.232.14.2.4.1.1.16 type: gauge help: ATA Disk Type other(1) The agent cannot determine the disk type - 1.3.6.1.4.1.232.14.2.4.1.1.16 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: ata 3: sata - name: cpqIdeAtaDiskSataVersion oid: 1.3.6.1.4.1.232.14.2.4.1.1.17 type: gauge help: Physical Drive SATA Version - 1.3.6.1.4.1.232.14.2.4.1.1.17 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: sataOne 3: sataTwo - name: cpqIdeAtaDiskMediaType oid: 1.3.6.1.4.1.232.14.2.4.1.1.18 type: gauge help: SATA Physical Drive Media Type - 1.3.6.1.4.1.232.14.2.4.1.1.18 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: rotatingPlatters 3: solidState - name: cpqIdeAtaDiskSSDWearStatus oid: 1.3.6.1.4.1.232.14.2.4.1.1.19 type: gauge help: SATA Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.14.2.4.1.1.19 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: ok 3: fiftySixDayThreshold 4: fivePercentThreshold 5: twoPercentThreshold 6: ssdWearOut - name: cpqIdeAtaDiskPowerOnHours oid: 1.3.6.1.4.1.232.14.2.4.1.1.20 type: counter help: SATA Physical Drive Power On Hours - 1.3.6.1.4.1.232.14.2.4.1.1.20 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskSSDPercntEndrnceUsed oid: 1.3.6.1.4.1.232.14.2.4.1.1.21 type: gauge help: SATA Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.14.2.4.1.1.21 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskSSDEstTimeRemainingHours oid: 1.3.6.1.4.1.232.14.2.4.1.1.22 type: counter help: SATA Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.14.2.4.1.1.22 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskCurrTemperature oid: 1.3.6.1.4.1.232.14.2.4.1.1.23 type: gauge help: SATA Physical Drive Current Operating Temperature degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.23 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskTemperatureThreshold oid: 1.3.6.1.4.1.232.14.2.4.1.1.24 type: gauge help: SATA Physical Drive Maximum Operating Temperature in degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.24 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskMaximumOperatingTemp oid: 1.3.6.1.4.1.232.14.2.4.1.1.25 type: gauge help: SATA Physical Drive Maximum Operating Temperature, as specified by the manufacturer, in degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.25 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskDestructiveOperatingTemp oid: 1.3.6.1.4.1.232.14.2.4.1.1.26 type: gauge help: SATA Physical Drive Destructive Operating Temperature, as specified by the manufacturer, in degrees Celsius, which if exceeded can cause damage to the drive - 1.3.6.1.4.1.232.14.2.4.1.1.26 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaEraseFailureType oid: 1.3.6.1.4.1.232.14.2.4.2 type: gauge help: The value specifies the secure erase status of SATA drive - 1.3.6.1.4.1.232.14.2.4.2 enum_values: 1: secureEraseFailed 2: secureEraseNotSupported 3: noEraseSupported - name: cpqIdeAtapiDeviceControllerIndex oid: 1.3.6.1.4.1.232.14.2.5.1.1.1 type: gauge help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.5.1.1.1 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge - name: cpqIdeAtapiDeviceIndex oid: 1.3.6.1.4.1.232.14.2.5.1.1.2 type: gauge help: An index that uniquely identifies each ATAPI device. - 1.3.6.1.4.1.232.14.2.5.1.1.2 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge - name: cpqIdeAtapiDeviceModel oid: 1.3.6.1.4.1.232.14.2.5.1.1.3 type: DisplayString help: ATAPI Device Model - 1.3.6.1.4.1.232.14.2.5.1.1.3 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge - name: cpqIdeAtapiDeviceFwRev oid: 1.3.6.1.4.1.232.14.2.5.1.1.4 type: DisplayString help: ATAPI Device Firmware Revision - 1.3.6.1.4.1.232.14.2.5.1.1.4 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge - name: cpqIdeAtapiDeviceType oid: 1.3.6.1.4.1.232.14.2.5.1.1.5 type: gauge help: ATAPI Device Type - 1.3.6.1.4.1.232.14.2.5.1.1.5 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge enum_values: 1: other 2: disk 3: tape 4: printer 5: processor 6: wormDrive 7: cd-rom 8: scanner 9: optical 10: jukeBox 11: commDev - name: cpqIdeAtapiDeviceTypeExtended oid: 1.3.6.1.4.1.232.14.2.5.1.1.6 type: gauge help: ATAPI Extended Device Type - 1.3.6.1.4.1.232.14.2.5.1.1.6 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge enum_values: 1: other 2: pdcd 3: removableDisk - name: cpqIdeAtapiDeviceChannel oid: 1.3.6.1.4.1.232.14.2.5.1.1.7 type: gauge help: ATAPI Device Channel - 1.3.6.1.4.1.232.14.2.5.1.1.7 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge enum_values: 1: other 2: channel0 3: channel1 - name: cpqIdeAtapiDeviceNumber oid: 1.3.6.1.4.1.232.14.2.5.1.1.8 type: gauge help: ATAPI Device Number - 1.3.6.1.4.1.232.14.2.5.1.1.8 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge enum_values: 1: other 2: device0 3: device1 - name: cpqIdeLogicalDriveControllerIndex oid: 1.3.6.1.4.1.232.14.2.6.1.1.1 type: gauge help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.6.1.1.1 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveIndex oid: 1.3.6.1.4.1.232.14.2.6.1.1.2 type: gauge help: An index that uniquely identifies each logical drive. - 1.3.6.1.4.1.232.14.2.6.1.1.2 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveRaidLevel oid: 1.3.6.1.4.1.232.14.2.6.1.1.3 type: gauge help: IDE Logical Drive RAID Level - 1.3.6.1.4.1.232.14.2.6.1.1.3 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge enum_values: 1: other 2: raid0 3: raid1 4: raid0plus1 5: raid5 6: raid15 7: volume - name: cpqIdeLogicalDriveCapacity oid: 1.3.6.1.4.1.232.14.2.6.1.1.4 type: gauge help: IDE Logical Drive Capacity - 1.3.6.1.4.1.232.14.2.6.1.1.4 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveStatus oid: 1.3.6.1.4.1.232.14.2.6.1.1.5 type: gauge help: IDE Logical Drive Status - 1.3.6.1.4.1.232.14.2.6.1.1.5 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: rebuilding 5: failed - name: cpqIdeLogicalDriveCondition oid: 1.3.6.1.4.1.232.14.2.6.1.1.6 type: gauge help: IDE Logical Drive Condition - 1.3.6.1.4.1.232.14.2.6.1.1.6 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeLogicalDriveDiskIds oid: 1.3.6.1.4.1.232.14.2.6.1.1.7 type: OctetString help: IDE Logical Drive Disk ID list - 1.3.6.1.4.1.232.14.2.6.1.1.7 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveStripeSize oid: 1.3.6.1.4.1.232.14.2.6.1.1.8 type: gauge help: IDE Logical Drive Stripe Size - 1.3.6.1.4.1.232.14.2.6.1.1.8 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveSpareIds oid: 1.3.6.1.4.1.232.14.2.6.1.1.9 type: OctetString help: IDE Logical Drive Spare ID list - 1.3.6.1.4.1.232.14.2.6.1.1.9 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveRebuildingDisk oid: 1.3.6.1.4.1.232.14.2.6.1.1.10 type: gauge help: IDE Logical Drive Rebuilding Disk - 1.3.6.1.4.1.232.14.2.6.1.1.10 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveOsName oid: 1.3.6.1.4.1.232.14.2.6.1.1.11 type: DisplayString help: IDE Logical Drive OS Name - 1.3.6.1.4.1.232.14.2.6.1.1.11 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqDaCntlrIndex oid: 1.3.6.1.4.1.232.3.2.2.1.1.1 type: gauge help: Array Controller Index - 1.3.6.1.4.1.232.3.2.2.1.1.1 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrModel oid: 1.3.6.1.4.1.232.3.2.2.1.1.2 type: gauge help: Array Controller Model - 1.3.6.1.4.1.232.3.2.2.1.1.2 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ida 3: idaExpansion 4: ida-2 5: smart 6: smart-2e 7: smart-2p 8: smart-2sl 9: smart-3100es 10: smart-3200 11: smart-2dh 12: smart-221 13: sa-4250es 14: sa-4200 15: sa-integrated 16: sa-431 17: sa-5300 18: raidLc2 19: sa-5i 20: sa-532 21: sa-5312 22: sa-641 23: sa-642 24: sa-6400 25: sa-6400em 26: sa-6i 27: sa-generic 29: sa-p600 30: sa-p400 31: sa-e200 32: sa-e200i 33: sa-p400i 34: sa-p800 35: sa-e500 36: sa-p700m 37: sa-p212 38: sa-p410 39: sa-p410i 40: sa-p411 41: sa-b110i 42: sa-p712m 43: sa-p711m 44: sa-p812 45: sw-1210m 46: sa-p220i 47: sa-p222 48: sa-p420 49: sa-p420i 50: sa-p421 51: sa-b320i 52: sa-p822 53: sa-p721m 54: sa-b120i 55: hps-1224 56: hps-1228 57: hps-1228m 58: sa-p822se 59: hps-1224e 60: hps-1228e 61: hps-1228em 62: sa-p230i 63: sa-p430i 64: sa-p430 65: sa-p431 66: sa-p731m 67: sa-p830i 68: sa-p830 69: sa-p831 70: sa-p530 71: sa-p531 72: sa-p244br 73: sa-p246br 74: sa-p440 75: sa-p440ar 76: sa-p441 77: sa-p741m 78: sa-p840 79: sa-p841 80: sh-h240ar 81: sh-h244br 82: sh-h240 83: sh-h241 84: sa-b140i 85: sh-generic 86: sa-p240nr 87: sh-h240nr 88: sa-p840ar 89: sa-p542d 90: s100i 91: e208i-p 92: e208i-a 93: e208i-c 94: e208e-p 95: p204i-b 96: p204i-c 97: p408i-p 98: p408i-a 99: p408e-p 100: p408i-c 101: p408e-m 102: p416ie-m 103: p816i-a 104: p408i-sb - name: cpqDaCntlrFWRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.3 type: DisplayString help: Array Controller Firmware Revision - 1.3.6.1.4.1.232.3.2.2.1.1.3 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrStndIntr oid: 1.3.6.1.4.1.232.3.2.2.1.1.4 type: gauge help: The status of the Standard Interface - 1.3.6.1.4.1.232.3.2.2.1.1.4 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: primary 3: secondary 4: disabled 5: unavailable - name: cpqDaCntlrSlot oid: 1.3.6.1.4.1.232.3.2.2.1.1.5 type: gauge help: Array Controller Slot - 1.3.6.1.4.1.232.3.2.2.1.1.5 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrCondition oid: 1.3.6.1.4.1.232.3.2.2.1.1.6 type: gauge help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.6 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaCntlrProductRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.7 type: DisplayString help: Array Controller Product Revision - 1.3.6.1.4.1.232.3.2.2.1.1.7 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrPartnerSlot oid: 1.3.6.1.4.1.232.3.2.2.1.1.8 type: gauge help: Array Controller Partner Slot - 1.3.6.1.4.1.232.3.2.2.1.1.8 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrCurrentRole oid: 1.3.6.1.4.1.232.3.2.2.1.1.9 type: gauge help: Array Controller Current Role - 1.3.6.1.4.1.232.3.2.2.1.1.9 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notDuplexed 3: active 4: backup 5: asymActiveActive - name: cpqDaCntlrBoardStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.10 type: gauge help: Array Controller Board Status - 1.3.6.1.4.1.232.3.2.2.1.1.10 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: generalFailure 4: cableProblem 5: poweredOff 6: cacheModuleMissing - name: cpqDaCntlrPartnerBoardStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.11 type: gauge help: Array Controller Partner Board Status - 1.3.6.1.4.1.232.3.2.2.1.1.11 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: generalFailure 4: cableProblem 5: poweredOff - name: cpqDaCntlrBoardCondition oid: 1.3.6.1.4.1.232.3.2.2.1.1.12 type: gauge help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.12 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaCntlrPartnerBoardCondition oid: 1.3.6.1.4.1.232.3.2.2.1.1.13 type: gauge help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.13 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaCntlrDriveOwnership oid: 1.3.6.1.4.1.232.3.2.2.1.1.14 type: gauge help: Array Controller Drive Ownership - 1.3.6.1.4.1.232.3.2.2.1.1.14 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: owner 3: notOwner - name: cpqDaCntlrSerialNumber oid: 1.3.6.1.4.1.232.3.2.2.1.1.15 type: DisplayString help: Array Controller Serial Number - 1.3.6.1.4.1.232.3.2.2.1.1.15 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrRedundancyType oid: 1.3.6.1.4.1.232.3.2.2.1.1.16 type: gauge help: Array Controller Redundancy Type - 1.3.6.1.4.1.232.3.2.2.1.1.16 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notRedundant 3: driverDuplexing 4: fwActiveStandby 5: fwPrimarySecondary 6: fwActiveActive - name: cpqDaCntlrRedundancyError oid: 1.3.6.1.4.1.232.3.2.2.1.1.17 type: gauge help: Array Controller Redundancy Error - 1.3.6.1.4.1.232.3.2.2.1.1.17 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: noFailure 3: noRedundantController 4: differentHardware 5: noLink 6: differentFirmware 7: differentCache 8: otherCacheFailure 9: noDrives 10: otherNoDrives 11: unsupportedDrives 12: expandInProgress - name: cpqDaCntlrAccessModuleStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.18 type: gauge help: Array Controller RAID ADG Enabler Module Status - 1.3.6.1.4.1.232.3.2.2.1.1.18 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notSupported 3: notPresent 4: badSignature 5: badChecksum 6: fullyFunctional 7: upgradeFirmware - name: cpqDaCntlrDaughterBoardType oid: 1.3.6.1.4.1.232.3.2.2.1.1.19 type: gauge help: Array Controller Daughter Board Type - 1.3.6.1.4.1.232.3.2.2.1.1.19 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notSupported 3: notPresent 4: scsiBoardPresent 5: fibreBoardPresent 6: arrayExpansionModulePresent - name: cpqDaCntlrHwLocation oid: 1.3.6.1.4.1.232.3.2.2.1.1.20 type: DisplayString help: A text description of the hardware location of the controller - 1.3.6.1.4.1.232.3.2.2.1.1.20 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrNumberOfBuses oid: 1.3.6.1.4.1.232.3.2.2.1.1.21 type: gauge help: Array Controller Number of Buses - 1.3.6.1.4.1.232.3.2.2.1.1.21 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrBlinkTime oid: 1.3.6.1.4.1.232.3.2.2.1.1.22 type: counter help: Controller Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.2.1.1.22 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrRebuildPriority oid: 1.3.6.1.4.1.232.3.2.2.1.1.23 type: gauge help: Array Controller Rebuild Priority - 1.3.6.1.4.1.232.3.2.2.1.1.23 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: low 3: medium 4: high 5: mediumHigh - name: cpqDaCntlrExpandPriority oid: 1.3.6.1.4.1.232.3.2.2.1.1.24 type: gauge help: Array Controller Expand Priority - 1.3.6.1.4.1.232.3.2.2.1.1.24 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: low 3: medium 4: high - name: cpqDaCntlrNumberOfInternalPorts oid: 1.3.6.1.4.1.232.3.2.2.1.1.25 type: gauge help: Array Controller Number of Internal Ports - 1.3.6.1.4.1.232.3.2.2.1.1.25 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrNumberOfExternalPorts oid: 1.3.6.1.4.1.232.3.2.2.1.1.26 type: gauge help: Array Controller Number of External Ports - 1.3.6.1.4.1.232.3.2.2.1.1.26 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrDriveWriteCacheState oid: 1.3.6.1.4.1.232.3.2.2.1.1.27 type: gauge help: Array Controller Drive Write Cache State - 1.3.6.1.4.1.232.3.2.2.1.1.27 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: disabled 3: enabled - name: cpqDaCntlrPartnerSerialNumber oid: 1.3.6.1.4.1.232.3.2.2.1.1.28 type: DisplayString help: Array Controller Partner Serial Number - 1.3.6.1.4.1.232.3.2.2.1.1.28 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrOptionRomRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.29 type: DisplayString help: Array Controller Option ROM Revision - 1.3.6.1.4.1.232.3.2.2.1.1.29 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrHbaFWRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.30 type: DisplayString help: Array Controller HBA Firmware Revision - 1.3.6.1.4.1.232.3.2.2.1.1.30 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrHBAModeOptionRomRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.31 type: DisplayString help: Array Controller HBA Mode Option Rom Revision - 1.3.6.1.4.1.232.3.2.2.1.1.31 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrCurrentTemp oid: 1.3.6.1.4.1.232.3.2.2.1.1.32 type: gauge help: Array Controller Current Temperature - 1.3.6.1.4.1.232.3.2.2.1.1.32 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrLastLockupCode oid: 1.3.6.1.4.1.232.3.2.2.1.1.33 type: gauge help: Array Controller Last Lockup Code - 1.3.6.1.4.1.232.3.2.2.1.1.33 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrEncryptionStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.34 type: gauge help: Array Controller Encryption Status - 1.3.6.1.4.1.232.3.2.2.1.1.34 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notEnabled 3: enabledLocalKeyMode 4: enabledRemoteKeyManagerMode - name: cpqDaCntlrASICEncptSelfTestStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.35 type: gauge help: Array Controller ASIC Encryption Self Test Status - 1.3.6.1.4.1.232.3.2.2.1.1.35 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: selfTestsPass 3: selfTestsFailed - name: cpqDaCntlrEncryptCspNvramStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.36 type: gauge help: Array Controller Encryption Critical Security Parameter NVRAM Status - 1.3.6.1.4.1.232.3.2.2.1.1.36 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: detectionFailed - name: cpqDaCntlrEncryptCryptoOfficerPwdSetStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.37 type: gauge help: Array Controller Encryption Crypto Officer Password Set Status - 1.3.6.1.4.1.232.3.2.2.1.1.37 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrEncryptCntlrPwdSetStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.38 type: gauge help: Array Controller Encryption Controller Password Set Status - 1.3.6.1.4.1.232.3.2.2.1.1.38 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrEncryptCntlrPwdAvailStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.39 type: gauge help: Array Controller Encryption Controller Password Availability Status - 1.3.6.1.4.1.232.3.2.2.1.1.39 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: passwordMissing 3: passwordActive - name: cpqDaCntlrUnencryptedLogDrvCreationPolicy oid: 1.3.6.1.4.1.232.3.2.2.1.1.40 type: gauge help: Array Controller Unencrypted Logical Drive Creation Policy - 1.3.6.1.4.1.232.3.2.2.1.1.40 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrEncryptedLogDrvCreationPolicy oid: 1.3.6.1.4.1.232.3.2.2.1.1.41 type: gauge help: Array Controller Encrypted Logical Drive Creation Policy - 1.3.6.1.4.1.232.3.2.2.1.1.41 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrEncryptFWLockStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.42 type: gauge help: Array Controller Encryption Firmware Lock Status - 1.3.6.1.4.1.232.3.2.2.1.1.42 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrOperatingMode oid: 1.3.6.1.4.1.232.3.2.2.1.1.43 type: gauge help: Array Controller Operating Mode - 1.3.6.1.4.1.232.3.2.2.1.1.43 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: smartArrayMode 3: smartHbaMode 4: mixedMode - name: cpqDaLogDrvCntlrIndex oid: 1.3.6.1.4.1.232.3.2.3.1.1.1 type: gauge help: Drive Array Logical Drive Controller Index - 1.3.6.1.4.1.232.3.2.3.1.1.1 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvIndex oid: 1.3.6.1.4.1.232.3.2.3.1.1.2 type: gauge help: Drive Array Logical Drive Index - 1.3.6.1.4.1.232.3.2.3.1.1.2 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvFaultTol oid: 1.3.6.1.4.1.232.3.2.3.1.1.3 type: gauge help: Logical Drive Fault Tolerance - 1.3.6.1.4.1.232.3.2.3.1.1.3 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: none 3: mirroring 4: dataGuard 5: distribDataGuard 7: advancedDataGuard 8: raid50 9: raid60 10: raid1Adm 11: raid10Adm 12: raid10 - name: cpqDaLogDrvStatus oid: 1.3.6.1.4.1.232.3.2.3.1.1.4 type: gauge help: Logical Drive Status - 1.3.6.1.4.1.232.3.2.3.1.1.4 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: unconfigured 5: recovering 6: readyForRebuild 7: rebuilding 8: wrongDrive 9: badConnect 10: overheating 11: shutdown 12: expanding 13: notAvailable 14: queuedForExpansion 15: multipathAccessDegraded 16: erasing 17: predictiveSpareRebuildReady 18: rapidParityInitInProgress 19: rapidParityInitPending 20: noAccessEncryptedNoCntlrKey 21: unencryptedToEncryptedInProgress 22: newLogDrvKeyRekeyInProgress 23: noAccessEncryptedCntlrEncryptnNotEnbld 24: unencryptedToEncryptedNotStarted 25: newLogDrvKeyRekeyRequestReceived - name: cpqDaLogDrvAutoRel oid: 1.3.6.1.4.1.232.3.2.3.1.1.5 type: gauge help: Array Controller Logical Drive Auto-Reliability Delay - 1.3.6.1.4.1.232.3.2.3.1.1.5 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvRebuildBlks oid: 1.3.6.1.4.1.232.3.2.3.1.1.6 type: counter help: Logical Drive Rebuild Blocks Remaining - 1.3.6.1.4.1.232.3.2.3.1.1.6 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvHasAccel oid: 1.3.6.1.4.1.232.3.2.3.1.1.7 type: gauge help: Logical Drive Has Cache Module Board - 1.3.6.1.4.1.232.3.2.3.1.1.7 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: unavailable 3: enabled 4: disabled - name: cpqDaLogDrvAvailSpares oid: 1.3.6.1.4.1.232.3.2.3.1.1.8 type: OctetString help: Drive Array Logical Drive Available Spares - 1.3.6.1.4.1.232.3.2.3.1.1.8 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvSize oid: 1.3.6.1.4.1.232.3.2.3.1.1.9 type: gauge help: Logical Drive Size - 1.3.6.1.4.1.232.3.2.3.1.1.9 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvPhyDrvIDs oid: 1.3.6.1.4.1.232.3.2.3.1.1.10 type: OctetString help: Drive Array Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.3.2.3.1.1.10 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvCondition oid: 1.3.6.1.4.1.232.3.2.3.1.1.11 type: gauge help: The Logical Drive condition - 1.3.6.1.4.1.232.3.2.3.1.1.11 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaLogDrvPercentRebuild oid: 1.3.6.1.4.1.232.3.2.3.1.1.12 type: gauge help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.3.2.3.1.1.12 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvStripeSize oid: 1.3.6.1.4.1.232.3.2.3.1.1.13 type: gauge help: Logical Drive Stripe Size - 1.3.6.1.4.1.232.3.2.3.1.1.13 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvOsName oid: 1.3.6.1.4.1.232.3.2.3.1.1.14 type: DisplayString help: Logical Drive OS Name - 1.3.6.1.4.1.232.3.2.3.1.1.14 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvBlinkTime oid: 1.3.6.1.4.1.232.3.2.3.1.1.15 type: counter help: Logical Drive Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.3.1.1.15 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvSpareReplaceMap oid: 1.3.6.1.4.1.232.3.2.3.1.1.16 type: OctetString help: Logical Drive Spare To Replacement Drive Map - 1.3.6.1.4.1.232.3.2.3.1.1.16 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvRebuildingPhyDrv oid: 1.3.6.1.4.1.232.3.2.3.1.1.17 type: gauge help: Logical Drive Physical Drive Rebuilding Index - 1.3.6.1.4.1.232.3.2.3.1.1.17 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvMultipathAccess oid: 1.3.6.1.4.1.232.3.2.3.1.1.18 type: gauge help: Logical Drive Multi-path Access - 1.3.6.1.4.1.232.3.2.3.1.1.18 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: notSupported 3: notConfigured 4: pathRedundant 5: noRedundantPath - name: cpqDaLogDrvNmbrOfParityGroups oid: 1.3.6.1.4.1.232.3.2.3.1.1.19 type: gauge help: Logical Drive Number Of Parity Groups - 1.3.6.1.4.1.232.3.2.3.1.1.19 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvSplitMirrorBackupLogDrv oid: 1.3.6.1.4.1.232.3.2.3.1.1.20 type: gauge help: Logical Drive Split Mirror Backup Logical Drive - 1.3.6.1.4.1.232.3.2.3.1.1.20 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: isNotBackupLogicalDrive 3: isBackupLogicalDrive - name: cpqDaLogDrvCacheVolAccelAssocType oid: 1.3.6.1.4.1.232.3.2.3.1.1.21 type: gauge help: Logical Drive Cache Volume Accelerator Association Type - 1.3.6.1.4.1.232.3.2.3.1.1.21 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: nonMember 3: logicalDriveMember 4: cacheVolumeMember - name: cpqDaLogDrvCacheVolIndex oid: 1.3.6.1.4.1.232.3.2.3.1.1.22 type: gauge help: Logical Drive Cache Volume Index - 1.3.6.1.4.1.232.3.2.3.1.1.22 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvRPIPercentComplete oid: 1.3.6.1.4.1.232.3.2.3.1.1.23 type: gauge help: Logical Drive Rapid Parity Initialization Percent Complete - 1.3.6.1.4.1.232.3.2.3.1.1.23 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvSSDSmartPathStatus oid: 1.3.6.1.4.1.232.3.2.3.1.1.24 type: gauge help: Logical Drive SSD Smart Path Status - 1.3.6.1.4.1.232.3.2.3.1.1.24 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: updateDriver 3: ssdSmartPathDisabled 4: ssdSmartPathEnabled - name: cpqDaLogDrvEncryptionStatus oid: 1.3.6.1.4.1.232.3.2.3.1.1.25 type: gauge help: Logical Drive Encryption Status - 1.3.6.1.4.1.232.3.2.3.1.1.25 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: encrypted 3: notEncrypted - name: cpqDaPhyDrvCntlrIndex oid: 1.3.6.1.4.1.232.3.2.5.1.1.1 type: gauge help: Drive Array Physical Drive Controller Index - 1.3.6.1.4.1.232.3.2.5.1.1.1 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvIndex oid: 1.3.6.1.4.1.232.3.2.5.1.1.2 type: gauge help: Drive Array Physical Drive Index - 1.3.6.1.4.1.232.3.2.5.1.1.2 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvModel oid: 1.3.6.1.4.1.232.3.2.5.1.1.3 type: DisplayString help: Physical Drive Model - 1.3.6.1.4.1.232.3.2.5.1.1.3 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFWRev oid: 1.3.6.1.4.1.232.3.2.5.1.1.4 type: DisplayString help: Physical Drive Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.4 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBay oid: 1.3.6.1.4.1.232.3.2.5.1.1.5 type: gauge help: Physical Drive Bay Location - 1.3.6.1.4.1.232.3.2.5.1.1.5 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.6 type: gauge help: Physical Drive Status - 1.3.6.1.4.1.232.3.2.5.1.1.6 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: predictiveFailure 5: erasing 6: eraseDone 7: eraseQueued 8: ssdWearOut 9: notAuthenticated - name: cpqDaPhyDrvFactReallocs oid: 1.3.6.1.4.1.232.3.2.5.1.1.7 type: gauge help: This shows the number of spare sectors available for remapping at the time the physical drive was shipped - 1.3.6.1.4.1.232.3.2.5.1.1.7 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvUsedReallocs oid: 1.3.6.1.4.1.232.3.2.5.1.1.8 type: counter help: Physical Drive Used Reallocated Sectors - 1.3.6.1.4.1.232.3.2.5.1.1.8 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvRefHours oid: 1.3.6.1.4.1.232.3.2.5.1.1.9 type: counter help: Reference Time in hours - 1.3.6.1.4.1.232.3.2.5.1.1.9 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHReads oid: 1.3.6.1.4.1.232.3.2.5.1.1.10 type: counter help: Sectors Read (high) - 1.3.6.1.4.1.232.3.2.5.1.1.10 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvReads oid: 1.3.6.1.4.1.232.3.2.5.1.1.11 type: counter help: Sectors Read (low) - 1.3.6.1.4.1.232.3.2.5.1.1.11 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHWrites oid: 1.3.6.1.4.1.232.3.2.5.1.1.12 type: counter help: Sectors Written (high) - 1.3.6.1.4.1.232.3.2.5.1.1.12 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvWrites oid: 1.3.6.1.4.1.232.3.2.5.1.1.13 type: counter help: Sectors Written (low) - 1.3.6.1.4.1.232.3.2.5.1.1.13 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHSeeks oid: 1.3.6.1.4.1.232.3.2.5.1.1.14 type: counter help: Total Seeks (high) - 1.3.6.1.4.1.232.3.2.5.1.1.14 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSeeks oid: 1.3.6.1.4.1.232.3.2.5.1.1.15 type: counter help: Total Seeks (low) - 1.3.6.1.4.1.232.3.2.5.1.1.15 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHardReadErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.16 type: counter help: Hard Read Errors - 1.3.6.1.4.1.232.3.2.5.1.1.16 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvRecvReadErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.17 type: counter help: Recovered Read Errors - 1.3.6.1.4.1.232.3.2.5.1.1.17 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHardWriteErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.18 type: counter help: Hard Write Errors - 1.3.6.1.4.1.232.3.2.5.1.1.18 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvRecvWriteErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.19 type: counter help: Recovered Write Errors - 1.3.6.1.4.1.232.3.2.5.1.1.19 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHSeekErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.20 type: counter help: Seek Errors (High) - 1.3.6.1.4.1.232.3.2.5.1.1.20 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSeekErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.21 type: counter help: Seek Errors (low) - 1.3.6.1.4.1.232.3.2.5.1.1.21 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSpinupTime oid: 1.3.6.1.4.1.232.3.2.5.1.1.22 type: gauge help: Spin up Time in tenths of seconds - 1.3.6.1.4.1.232.3.2.5.1.1.22 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFunctTest1 oid: 1.3.6.1.4.1.232.3.2.5.1.1.23 type: gauge help: Functional Test 1 - 1.3.6.1.4.1.232.3.2.5.1.1.23 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFunctTest2 oid: 1.3.6.1.4.1.232.3.2.5.1.1.24 type: gauge help: Functional Test 2 - 1.3.6.1.4.1.232.3.2.5.1.1.24 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFunctTest3 oid: 1.3.6.1.4.1.232.3.2.5.1.1.25 type: gauge help: Functional Test 3 - 1.3.6.1.4.1.232.3.2.5.1.1.25 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvDrqTimeouts oid: 1.3.6.1.4.1.232.3.2.5.1.1.26 type: counter help: DRQ Timeouts - 1.3.6.1.4.1.232.3.2.5.1.1.26 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvOtherTimeouts oid: 1.3.6.1.4.1.232.3.2.5.1.1.27 type: counter help: Other Timeouts - 1.3.6.1.4.1.232.3.2.5.1.1.27 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSpinupRetries oid: 1.3.6.1.4.1.232.3.2.5.1.1.28 type: counter help: Spin up Retries - 1.3.6.1.4.1.232.3.2.5.1.1.28 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBadRecvReads oid: 1.3.6.1.4.1.232.3.2.5.1.1.29 type: counter help: Recovery Failed (Bad) Read Error - 1.3.6.1.4.1.232.3.2.5.1.1.29 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBadRecvWrites oid: 1.3.6.1.4.1.232.3.2.5.1.1.30 type: counter help: Recovery Failed (Bad) Write Error - 1.3.6.1.4.1.232.3.2.5.1.1.30 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFormatErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.31 type: counter help: Format Error - 1.3.6.1.4.1.232.3.2.5.1.1.31 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvPostErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.32 type: counter help: Power On Self Test (Post) Error - 1.3.6.1.4.1.232.3.2.5.1.1.32 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvNotReadyErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.33 type: counter help: Drive Not Ready Errors - 1.3.6.1.4.1.232.3.2.5.1.1.33 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvReallocAborts oid: 1.3.6.1.4.1.232.3.2.5.1.1.34 type: counter help: Physical Drive Reallocation Aborts - 1.3.6.1.4.1.232.3.2.5.1.1.34 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvThreshPassed oid: 1.3.6.1.4.1.232.3.2.5.1.1.35 type: gauge help: Physical Drive Factory Threshold Passed (Exceeded) - 1.3.6.1.4.1.232.3.2.5.1.1.35 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: "false" 2: "true" - name: cpqDaPhyDrvHasMonInfo oid: 1.3.6.1.4.1.232.3.2.5.1.1.36 type: gauge help: Physical Drive Has Monitor Information - 1.3.6.1.4.1.232.3.2.5.1.1.36 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: "false" 2: "true" - name: cpqDaPhyDrvCondition oid: 1.3.6.1.4.1.232.3.2.5.1.1.37 type: gauge help: The condition of the device - 1.3.6.1.4.1.232.3.2.5.1.1.37 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaPhyDrvHotPlugs oid: 1.3.6.1.4.1.232.3.2.5.1.1.38 type: counter help: Physical Drive Hot Plug Count - 1.3.6.1.4.1.232.3.2.5.1.1.38 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvMediaErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.39 type: counter help: Physical Drive Media Failure Count - 1.3.6.1.4.1.232.3.2.5.1.1.39 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHardwareErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.40 type: counter help: Physical Drive Hardware Error Count - 1.3.6.1.4.1.232.3.2.5.1.1.40 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvAbortedCmds oid: 1.3.6.1.4.1.232.3.2.5.1.1.41 type: counter help: Physical Drive Aborted Command Failures - 1.3.6.1.4.1.232.3.2.5.1.1.41 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSpinUpErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.42 type: counter help: Physical Drive Spin-Up Failure Count - 1.3.6.1.4.1.232.3.2.5.1.1.42 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBadTargetErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.43 type: counter help: Physical Drive Bad Target Count - 1.3.6.1.4.1.232.3.2.5.1.1.43 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvLocation oid: 1.3.6.1.4.1.232.3.2.5.1.1.44 type: gauge help: Drive Physical Location - 1.3.6.1.4.1.232.3.2.5.1.1.44 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: internal 3: external 4: proLiant - name: cpqDaPhyDrvSize oid: 1.3.6.1.4.1.232.3.2.5.1.1.45 type: gauge help: Physical Drive Size in MB - 1.3.6.1.4.1.232.3.2.5.1.1.45 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBusFaults oid: 1.3.6.1.4.1.232.3.2.5.1.1.46 type: counter help: Physical Drive Bus Fault Count - 1.3.6.1.4.1.232.3.2.5.1.1.46 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvIrqDeglitches oid: 1.3.6.1.4.1.232.3.2.5.1.1.47 type: counter help: Physical Drive IRQ Deglitch Count - 1.3.6.1.4.1.232.3.2.5.1.1.47 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHotPlug oid: 1.3.6.1.4.1.232.3.2.5.1.1.48 type: gauge help: Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.3.2.5.1.1.48 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: hotPlug 3: nonHotPlug - name: cpqDaPhyDrvPlacement oid: 1.3.6.1.4.1.232.3.2.5.1.1.49 type: gauge help: Physical Drive Placement - 1.3.6.1.4.1.232.3.2.5.1.1.49 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: internal 3: external - name: cpqDaPhyDrvBusNumber oid: 1.3.6.1.4.1.232.3.2.5.1.1.50 type: gauge help: Physical Drive SCSI Bus Number - 1.3.6.1.4.1.232.3.2.5.1.1.50 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSerialNum oid: 1.3.6.1.4.1.232.3.2.5.1.1.51 type: DisplayString help: Physical Drive Serial Number - 1.3.6.1.4.1.232.3.2.5.1.1.51 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvPreFailMonitoring oid: 1.3.6.1.4.1.232.3.2.5.1.1.52 type: gauge help: Drive Array Physical Drive Predictive Failure Monitoring - 1.3.6.1.4.1.232.3.2.5.1.1.52 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: notAvailable 3: available - name: cpqDaPhyDrvCurrentWidth oid: 1.3.6.1.4.1.232.3.2.5.1.1.53 type: gauge help: Drive Array Physical Drive Current Width - 1.3.6.1.4.1.232.3.2.5.1.1.53 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: narrow 3: wide16 - name: cpqDaPhyDrvCurrentSpeed oid: 1.3.6.1.4.1.232.3.2.5.1.1.54 type: gauge help: Drive Array Physical Drive Current Data Transfer Speed - 1.3.6.1.4.1.232.3.2.5.1.1.54 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: asynchronous 3: fast 4: ultra 5: ultra2 6: ultra3 7: ultra320 - name: cpqDaPhyDrvFailureCode oid: 1.3.6.1.4.1.232.3.2.5.1.1.55 type: gauge help: Drive Array Physical Drive Failure Code - 1.3.6.1.4.1.232.3.2.5.1.1.55 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBlinkTime oid: 1.3.6.1.4.1.232.3.2.5.1.1.56 type: counter help: Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.5.1.1.56 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSmartStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.57 type: gauge help: Physical Drive S.M.A.R.T Status - 1.3.6.1.4.1.232.3.2.5.1.1.57 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: replaceDrive 4: replaceDriveSSDWearOut - name: cpqDaPhyDrvConfigurationStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.58 type: gauge help: Physical Drive Configuration Status - 1.3.6.1.4.1.232.3.2.5.1.1.58 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: configured 3: notConfigured - name: cpqDaPhyDrvRotationalSpeed oid: 1.3.6.1.4.1.232.3.2.5.1.1.59 type: gauge help: Drive Array Physical Drive Rotational Speed - 1.3.6.1.4.1.232.3.2.5.1.1.59 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: rpm7200 3: rpm10K 4: rpm15K 5: rpmSsd - name: cpqDaPhyDrvType oid: 1.3.6.1.4.1.232.3.2.5.1.1.60 type: gauge help: Physical Drive Type - 1.3.6.1.4.1.232.3.2.5.1.1.60 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: parallelScsi 3: sata 4: sas - name: cpqDaPhyDrvSataVersion oid: 1.3.6.1.4.1.232.3.2.5.1.1.61 type: gauge help: Physical Drive SATA Version - 1.3.6.1.4.1.232.3.2.5.1.1.61 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: sataOne 3: sataTwo - name: cpqDaPhyDrvHostConnector oid: 1.3.6.1.4.1.232.3.2.5.1.1.62 type: DisplayString help: Physical Drive Host Connector - 1.3.6.1.4.1.232.3.2.5.1.1.62 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBoxOnConnector oid: 1.3.6.1.4.1.232.3.2.5.1.1.63 type: gauge help: Physical Drive Box on Connector - 1.3.6.1.4.1.232.3.2.5.1.1.63 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvLocationString oid: 1.3.6.1.4.1.232.3.2.5.1.1.64 type: DisplayString help: Physical Drive Location String - 1.3.6.1.4.1.232.3.2.5.1.1.64 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvNegotiatedLinkRate oid: 1.3.6.1.4.1.232.3.2.5.1.1.65 type: gauge help: Drive Array Physical Drive Negotiated Link Rate - 1.3.6.1.4.1.232.3.2.5.1.1.65 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: rate-1-5 3: rate-3-0 4: rate-6-0 5: rate-12-0 - name: cpqDaPhyDrvNcqSupport oid: 1.3.6.1.4.1.232.3.2.5.1.1.66 type: gauge help: Drive Array Physical Drive Native Command Queueing - 1.3.6.1.4.1.232.3.2.5.1.1.66 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: noControllerSupport 3: noDriveSupport 4: ncqDisabled 5: ncqEnabled - name: cpqDaPhyDrvPhyCount oid: 1.3.6.1.4.1.232.3.2.5.1.1.67 type: gauge help: Drive Array Physical Drive PHY Count - 1.3.6.1.4.1.232.3.2.5.1.1.67 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvMultipathAccess oid: 1.3.6.1.4.1.232.3.2.5.1.1.68 type: gauge help: Drive Array Physical Drive Multi-path Access Status - 1.3.6.1.4.1.232.3.2.5.1.1.68 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: notSupported 3: notConfigured 4: pathRedundant 5: noRedundantPath 6: driveFailed - name: cpqDaPhyDrvMediaType oid: 1.3.6.1.4.1.232.3.2.5.1.1.69 type: gauge help: Drive Array Physical Drive Media Type - 1.3.6.1.4.1.232.3.2.5.1.1.69 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: rotatingPlatters 3: solidState 4: smr - name: cpqDaPhyDrvCurrentTemperature oid: 1.3.6.1.4.1.232.3.2.5.1.1.70 type: gauge help: Drive Array Physical Drive Current Temperature - 1.3.6.1.4.1.232.3.2.5.1.1.70 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvTemperatureThreshold oid: 1.3.6.1.4.1.232.3.2.5.1.1.71 type: gauge help: Drive Array Physical Drive Temperature Threshold - 1.3.6.1.4.1.232.3.2.5.1.1.71 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvMaximumTemperature oid: 1.3.6.1.4.1.232.3.2.5.1.1.72 type: gauge help: Drive Array Physical Drive Maximum Temperature - 1.3.6.1.4.1.232.3.2.5.1.1.72 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSSDWearStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.73 type: gauge help: Drive Array Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.3.2.5.1.1.73 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: fiftySixDayThreshold 4: fivePercentThreshold 5: twoPercentThreshold 6: ssdWearOut - name: cpqDaPhyDrvPowerOnHours oid: 1.3.6.1.4.1.232.3.2.5.1.1.74 type: counter help: Drive Array Physical Drive Power On Hours - 1.3.6.1.4.1.232.3.2.5.1.1.74 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSSDPercntEndrnceUsed oid: 1.3.6.1.4.1.232.3.2.5.1.1.75 type: gauge help: Drive Array Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.3.2.5.1.1.75 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSSDEstTimeRemainingHours oid: 1.3.6.1.4.1.232.3.2.5.1.1.76 type: counter help: Drive Array Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.3.2.5.1.1.76 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvAuthenticationStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.77 type: gauge help: Drive Array Physical Drive Authentication Status - 1.3.6.1.4.1.232.3.2.5.1.1.77 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: notSupported 3: authenticationFailed 4: authenticationPassed - name: cpqDaPhyDrvSmartCarrierAppFWRev oid: 1.3.6.1.4.1.232.3.2.5.1.1.78 type: gauge help: Physical Drive Smart Carrier Application Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.78 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSmartCarrierBootldrFWRev oid: 1.3.6.1.4.1.232.3.2.5.1.1.79 type: gauge help: Physical Drive Smart Carrier Bootloader Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.79 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvEncryptionStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.80 type: gauge help: Physical Drive Encryption Status - 1.3.6.1.4.1.232.3.2.5.1.1.80 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: encrypted 3: notEncrypted - name: cpqScsiMibRevMajor oid: 1.3.6.1.4.1.232.5.1.1 type: gauge help: The Major Revision level - 1.3.6.1.4.1.232.5.1.1 - name: cpqScsiMibRevMinor oid: 1.3.6.1.4.1.232.5.1.2 type: gauge help: The Minor Revision level - 1.3.6.1.4.1.232.5.1.2 - name: cpqScsiMibCondition oid: 1.3.6.1.4.1.232.5.1.3 type: gauge help: The overall condition - 1.3.6.1.4.1.232.5.1.3 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqScsiNw3xDriverName oid: 1.3.6.1.4.1.232.5.2.1.1.1 type: DisplayString help: SCSI Drive Device Driver Name - 1.3.6.1.4.1.232.5.2.1.1.1 - name: cpqScsiNw3xDriverVers oid: 1.3.6.1.4.1.232.5.2.1.1.2 type: DisplayString help: SCSI Drive Device Driver Version - 1.3.6.1.4.1.232.5.2.1.1.2 - name: cpqScsiNw3xDriverPollType oid: 1.3.6.1.4.1.232.5.2.1.1.3 type: gauge help: SCSI Drive Device Driver Poll Type - 1.3.6.1.4.1.232.5.2.1.1.3 enum_values: 1: other 2: polled 3: demand - name: cpqScsiNw3xDriverPollTime oid: 1.3.6.1.4.1.232.5.2.1.1.4 type: gauge help: SCSI Drive Device Driver Poll Time - 1.3.6.1.4.1.232.5.2.1.1.4 - name: cpqScsiNw3xCntlrIndex oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.1 type: gauge help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.1.1.5.1.1 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xBusIndex oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.2 type: gauge help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.5.1.2 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xXptDesc oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.3 type: DisplayString help: SCSI XPT Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.3 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xXptVers oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.4 type: DisplayString help: SCSI XPT Version - 1.3.6.1.4.1.232.5.2.1.1.5.1.4 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xSimDesc oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.5 type: DisplayString help: SCSI SIM Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.5 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xSimVers oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.6 type: DisplayString help: SCSI SIM Version - 1.3.6.1.4.1.232.5.2.1.1.5.1.6 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xHbaDesc oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.7 type: DisplayString help: SCSI HBA Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.7 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xStatCntlrIndex oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.1 type: gauge help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.1 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xStatBusIndex oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.2 type: gauge help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.2 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xStatLogDrvIndex oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.3 type: gauge help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.3 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xTotalReads oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.4 type: counter help: SCSI Logical Drive Total Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.4 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xTotalWrites oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.5 type: counter help: SCSI Logical Drive Total Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.5 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xCorrReads oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.6 type: counter help: SCSI Logical Drive Corrected Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.6 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xCorrWrites oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.7 type: counter help: SCSI Logical Drive Corrected Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.7 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xFatalReads oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.8 type: counter help: SCSI Logical Drive Fatal Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.8 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xFatalWrites oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.9 type: counter help: SCSI Logical Drive Fatal Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.9 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xVolCntlrIndex oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.1 type: gauge help: SCSI Cntlr Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.1 indexes: - labelname: cpqScsiNw3xVolCntlrIndex type: gauge - labelname: cpqScsiNw3xVolBusIndex type: gauge - labelname: cpqScsiNw3xVolLogDrvIndex type: gauge - name: cpqScsiNw3xVolBusIndex oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.2 type: gauge help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.2 indexes: - labelname: cpqScsiNw3xVolCntlrIndex type: gauge - labelname: cpqScsiNw3xVolBusIndex type: gauge - labelname: cpqScsiNw3xVolLogDrvIndex type: gauge - name: cpqScsiNw3xVolLogDrvIndex oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.3 type: gauge help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.3 indexes: - labelname: cpqScsiNw3xVolCntlrIndex type: gauge - labelname: cpqScsiNw3xVolBusIndex type: gauge - labelname: cpqScsiNw3xVolLogDrvIndex type: gauge - name: cpqScsiNw3xVolMap oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.4 type: OctetString help: SCSI Drive Volume Map - 1.3.6.1.4.1.232.5.2.1.1.7.1.4 indexes: - labelname: cpqScsiNw3xVolCntlrIndex type: gauge - labelname: cpqScsiNw3xVolBusIndex type: gauge - labelname: cpqScsiNw3xVolLogDrvIndex type: gauge - name: cpqScsiOsCommonPollFreq oid: 1.3.6.1.4.1.232.5.2.1.4.1 type: gauge help: The agent`s polling frequency - 1.3.6.1.4.1.232.5.2.1.4.1 - name: cpqScsiOsCommonModuleIndex oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.1 type: gauge help: A unique index for this module description. - 1.3.6.1.4.1.232.5.2.1.4.2.1.1 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiOsCommonModuleName oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.2 type: DisplayString help: The module name. - 1.3.6.1.4.1.232.5.2.1.4.2.1.2 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiOsCommonModuleVersion oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.3 type: DisplayString help: The module version in XX.YY format - 1.3.6.1.4.1.232.5.2.1.4.2.1.3 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiOsCommonModuleDate oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.4 type: OctetString help: The module date - 1.3.6.1.4.1.232.5.2.1.4.2.1.4 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiOsCommonModulePurpose oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.5 type: DisplayString help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.5.2.1.4.2.1.5 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiCntlrIndex oid: 1.3.6.1.4.1.232.5.2.2.1.1.1 type: gauge help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.2.1.1.1 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrBusIndex oid: 1.3.6.1.4.1.232.5.2.2.1.1.2 type: gauge help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.2.1.1.2 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrModel oid: 1.3.6.1.4.1.232.5.2.2.1.1.3 type: gauge help: SCSI Controller Model - 1.3.6.1.4.1.232.5.2.2.1.1.3 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge enum_values: 1: other 2: cpqs710 3: cpqs94 4: cpqs810p 5: cpqs825e 6: cpqs825p 7: cpqs974p 8: cpqs875p 9: extended 10: cpqs895p 11: cpqs896p 12: cpqa789x 13: cpqs876t 14: hpu320 15: hpu320r 16: generic 17: hp1u320g2 18: hp1u320g1 19: hpSc11Xe - name: cpqScsiCntlrFWVers oid: 1.3.6.1.4.1.232.5.2.2.1.1.4 type: DisplayString help: SCSI Controller Firmware Version - 1.3.6.1.4.1.232.5.2.2.1.1.4 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrSWVers oid: 1.3.6.1.4.1.232.5.2.2.1.1.5 type: DisplayString help: SCSI Controller Software Version - 1.3.6.1.4.1.232.5.2.2.1.1.5 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrSlot oid: 1.3.6.1.4.1.232.5.2.2.1.1.6 type: gauge help: SCSI Controller Slot - 1.3.6.1.4.1.232.5.2.2.1.1.6 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrStatus oid: 1.3.6.1.4.1.232.5.2.2.1.1.7 type: gauge help: SCSI Controller Status - 1.3.6.1.4.1.232.5.2.2.1.1.7 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge enum_values: 1: other 2: ok 3: failed - name: cpqScsiCntlrHardResets oid: 1.3.6.1.4.1.232.5.2.2.1.1.8 type: counter help: SCSI Controller Hard Resets - 1.3.6.1.4.1.232.5.2.2.1.1.8 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrSoftResets oid: 1.3.6.1.4.1.232.5.2.2.1.1.9 type: counter help: SCSI Controller Soft Resets - 1.3.6.1.4.1.232.5.2.2.1.1.9 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrTimeouts oid: 1.3.6.1.4.1.232.5.2.2.1.1.10 type: counter help: SCSI Controller Time-outs - 1.3.6.1.4.1.232.5.2.2.1.1.10 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrBaseIOAddr oid: 1.3.6.1.4.1.232.5.2.2.1.1.11 type: gauge help: SCSI Controller Base I/O Address - 1.3.6.1.4.1.232.5.2.2.1.1.11 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrCondition oid: 1.3.6.1.4.1.232.5.2.2.1.1.12 type: gauge help: SCSI Controller Condition - 1.3.6.1.4.1.232.5.2.2.1.1.12 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqScsiCntlrSerialNum oid: 1.3.6.1.4.1.232.5.2.2.1.1.13 type: DisplayString help: SCSI Controller Serial Number - 1.3.6.1.4.1.232.5.2.2.1.1.13 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrBusWidth oid: 1.3.6.1.4.1.232.5.2.2.1.1.14 type: gauge help: SCSI Controller Data Bus Width - 1.3.6.1.4.1.232.5.2.2.1.1.14 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge enum_values: 1: other 2: narrow 3: wide16 - name: cpqScsiCntlrModelExtended oid: 1.3.6.1.4.1.232.5.2.2.1.1.15 type: DisplayString help: SCSI Controller Model Name - 1.3.6.1.4.1.232.5.2.2.1.1.15 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrHwLocation oid: 1.3.6.1.4.1.232.5.2.2.1.1.16 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the SCSI controller - 1.3.6.1.4.1.232.5.2.2.1.1.16 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrPciLocation oid: 1.3.6.1.4.1.232.5.2.2.1.1.17 type: DisplayString help: A string designating the PCI device location for the controller, following the format DDDD:BB:DD.F, where DDDD is the PCI domain number, BB is the PCI bus number, DD is the PCI device number, and F is the PCI function number - 1.3.6.1.4.1.232.5.2.2.1.1.17 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiLogDrvCntlrIndex oid: 1.3.6.1.4.1.232.5.2.3.1.1.1 type: gauge help: SCSI Logical Drive Controller Index - 1.3.6.1.4.1.232.5.2.3.1.1.1 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvBusIndex oid: 1.3.6.1.4.1.232.5.2.3.1.1.2 type: gauge help: SCSI Logical Drive Bus Index - 1.3.6.1.4.1.232.5.2.3.1.1.2 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvIndex oid: 1.3.6.1.4.1.232.5.2.3.1.1.3 type: gauge help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.3.1.1.3 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvFaultTol oid: 1.3.6.1.4.1.232.5.2.3.1.1.4 type: gauge help: SCSI Logical Drive Fault Tolerance - 1.3.6.1.4.1.232.5.2.3.1.1.4 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge enum_values: 1: other 2: none 3: mirroring 4: dataGuard 5: distribDataGuard 6: enhancedMirroring - name: cpqScsiLogDrvStatus oid: 1.3.6.1.4.1.232.5.2.3.1.1.5 type: gauge help: SCSI Logical Drive Status - 1.3.6.1.4.1.232.5.2.3.1.1.5 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: unconfigured 5: recovering 6: readyForRebuild 7: rebuilding 8: wrongDrive 9: badConnect 10: degraded 11: disabled - name: cpqScsiLogDrvSize oid: 1.3.6.1.4.1.232.5.2.3.1.1.6 type: gauge help: SCSI Logical Drive Size - 1.3.6.1.4.1.232.5.2.3.1.1.6 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvPhyDrvIDs oid: 1.3.6.1.4.1.232.5.2.3.1.1.7 type: OctetString help: SCSI Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.5.2.3.1.1.7 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvCondition oid: 1.3.6.1.4.1.232.5.2.3.1.1.8 type: gauge help: SCSI Logical Drive Condition - 1.3.6.1.4.1.232.5.2.3.1.1.8 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqScsiLogDrvStripeSize oid: 1.3.6.1.4.1.232.5.2.3.1.1.9 type: gauge help: Logical Drive Stripe Size - 1.3.6.1.4.1.232.5.2.3.1.1.9 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvAvailSpares oid: 1.3.6.1.4.1.232.5.2.3.1.1.10 type: OctetString help: SCSI Logical Drive Available Spares - 1.3.6.1.4.1.232.5.2.3.1.1.10 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvPercentRebuild oid: 1.3.6.1.4.1.232.5.2.3.1.1.11 type: gauge help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.5.2.3.1.1.11 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvOsName oid: 1.3.6.1.4.1.232.5.2.3.1.1.12 type: DisplayString help: Logical Drive OS Name - 1.3.6.1.4.1.232.5.2.3.1.1.12 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiPhyDrvCntlrIndex oid: 1.3.6.1.4.1.232.5.2.4.1.1.1 type: gauge help: SCSI Physical Drive Controller Index - 1.3.6.1.4.1.232.5.2.4.1.1.1 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvBusIndex oid: 1.3.6.1.4.1.232.5.2.4.1.1.2 type: gauge help: SCSI Physical Drive Bus Index - 1.3.6.1.4.1.232.5.2.4.1.1.2 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvIndex oid: 1.3.6.1.4.1.232.5.2.4.1.1.3 type: gauge help: SCSI Physical Drive Index - 1.3.6.1.4.1.232.5.2.4.1.1.3 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvModel oid: 1.3.6.1.4.1.232.5.2.4.1.1.4 type: DisplayString help: SCSI Physical Drive Model - 1.3.6.1.4.1.232.5.2.4.1.1.4 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvFWRev oid: 1.3.6.1.4.1.232.5.2.4.1.1.5 type: DisplayString help: SCSI Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.2.4.1.1.5 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvVendor oid: 1.3.6.1.4.1.232.5.2.4.1.1.6 type: DisplayString help: SCSI Physical Drive Vendor - 1.3.6.1.4.1.232.5.2.4.1.1.6 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvSize oid: 1.3.6.1.4.1.232.5.2.4.1.1.7 type: gauge help: SCSI Physical Drive Size in MB - 1.3.6.1.4.1.232.5.2.4.1.1.7 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvScsiID oid: 1.3.6.1.4.1.232.5.2.4.1.1.8 type: gauge help: SCSI Physical Drive SCSI ID - 1.3.6.1.4.1.232.5.2.4.1.1.8 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvStatus oid: 1.3.6.1.4.1.232.5.2.4.1.1.9 type: gauge help: SCSI Physical Drive Status - 1.3.6.1.4.1.232.5.2.4.1.1.9 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: notConfigured 5: badCable 6: missingWasOk 7: missingWasFailed 8: predictiveFailure 9: missingWasPredictiveFailure 10: offline 11: missingWasOffline 12: hardError - name: cpqScsiPhyDrvServiceHours oid: 1.3.6.1.4.1.232.5.2.4.1.1.10 type: counter help: SCSI Physical Drive Service Time in hours - 1.3.6.1.4.1.232.5.2.4.1.1.10 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHighReadSectors oid: 1.3.6.1.4.1.232.5.2.4.1.1.11 type: counter help: SCSI Physical Drive Sectors Read (high) - 1.3.6.1.4.1.232.5.2.4.1.1.11 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvLowReadSectors oid: 1.3.6.1.4.1.232.5.2.4.1.1.12 type: counter help: SCSI Physical Drive Sectors Read (low) - 1.3.6.1.4.1.232.5.2.4.1.1.12 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHighWriteSectors oid: 1.3.6.1.4.1.232.5.2.4.1.1.13 type: counter help: SCSI Physical Drive Sectors Written (high) - 1.3.6.1.4.1.232.5.2.4.1.1.13 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvLowWriteSectors oid: 1.3.6.1.4.1.232.5.2.4.1.1.14 type: counter help: SCSI Physical Drive Sectors Written (low) - 1.3.6.1.4.1.232.5.2.4.1.1.14 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHardReadErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.15 type: counter help: SCSI Physical Drive Hard Read Errors - 1.3.6.1.4.1.232.5.2.4.1.1.15 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHardWriteErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.16 type: counter help: SCSI Physical Drive Hard Write Errors - 1.3.6.1.4.1.232.5.2.4.1.1.16 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvEccCorrReads oid: 1.3.6.1.4.1.232.5.2.4.1.1.17 type: counter help: SCSI Physical Drive ECC Corrected Read Errors (high) - 1.3.6.1.4.1.232.5.2.4.1.1.17 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvRecvReadErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.18 type: counter help: SCSI Physical Drive Recovered Read Errors - 1.3.6.1.4.1.232.5.2.4.1.1.18 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvRecvWriteErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.19 type: counter help: SCSI Physical Drive Recovered Write Errors - 1.3.6.1.4.1.232.5.2.4.1.1.19 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvSeekErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.20 type: counter help: SCSI Physical Drive Seek Errors - 1.3.6.1.4.1.232.5.2.4.1.1.20 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvSpinupTime oid: 1.3.6.1.4.1.232.5.2.4.1.1.21 type: gauge help: SCSI Physical Drive Spin up Time (tenths of seconds) - 1.3.6.1.4.1.232.5.2.4.1.1.21 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvUsedReallocs oid: 1.3.6.1.4.1.232.5.2.4.1.1.22 type: counter help: SCSI Physical Drive Used Reallocation Sectors - 1.3.6.1.4.1.232.5.2.4.1.1.22 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvTimeouts oid: 1.3.6.1.4.1.232.5.2.4.1.1.23 type: counter help: SCSI Physical Drive Time-out Errors - 1.3.6.1.4.1.232.5.2.4.1.1.23 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvPostErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.24 type: counter help: SCSI Physical Drive Power On Self Test (POST) Errors - 1.3.6.1.4.1.232.5.2.4.1.1.24 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvPostErrCode oid: 1.3.6.1.4.1.232.5.2.4.1.1.25 type: gauge help: SCSI Physical Drive Last POST Error Code - 1.3.6.1.4.1.232.5.2.4.1.1.25 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvCondition oid: 1.3.6.1.4.1.232.5.2.4.1.1.26 type: gauge help: SCSI Physical Drive Condition - 1.3.6.1.4.1.232.5.2.4.1.1.26 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqScsiPhyDrvFuncTest1 oid: 1.3.6.1.4.1.232.5.2.4.1.1.27 type: gauge help: SCSI Physical Drive Functional Test 1 - 1.3.6.1.4.1.232.5.2.4.1.1.27 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvFuncTest2 oid: 1.3.6.1.4.1.232.5.2.4.1.1.28 type: gauge help: SCSI Physical Drive Functional Test 2 - 1.3.6.1.4.1.232.5.2.4.1.1.28 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvStatsPreserved oid: 1.3.6.1.4.1.232.5.2.4.1.1.29 type: gauge help: SCSI Physical Drive Statistics Preservation Method - 1.3.6.1.4.1.232.5.2.4.1.1.29 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: inNVRAM 3: onDisk 4: noCPUSupport 5: noFreeNVRAM 6: noDrvSupport 7: noSoftwareSupport 8: statsNotSupported - name: cpqScsiPhyDrvSerialNum oid: 1.3.6.1.4.1.232.5.2.4.1.1.30 type: DisplayString help: SCSI Physical Drive Serial Number - 1.3.6.1.4.1.232.5.2.4.1.1.30 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvLocation oid: 1.3.6.1.4.1.232.5.2.4.1.1.31 type: gauge help: SCSI Physical Drive Location - 1.3.6.1.4.1.232.5.2.4.1.1.31 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: proliant - name: cpqScsiPhyDrvParent oid: 1.3.6.1.4.1.232.5.2.4.1.1.32 type: gauge help: SCSI Physical Drive Parent - 1.3.6.1.4.1.232.5.2.4.1.1.32 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvSectorSize oid: 1.3.6.1.4.1.232.5.2.4.1.1.33 type: gauge help: SCSI Physical Drive Sector Size in Bytes - 1.3.6.1.4.1.232.5.2.4.1.1.33 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHotPlug oid: 1.3.6.1.4.1.232.5.2.4.1.1.34 type: gauge help: SCSI Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.2.4.1.1.34 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: hotPlug 3: nonHotPlug - name: cpqScsiPhyDrvPlacement oid: 1.3.6.1.4.1.232.5.2.4.1.1.35 type: gauge help: SCSI Physical Drive Placement - 1.3.6.1.4.1.232.5.2.4.1.1.35 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: internal 3: external - name: cpqScsiPhyDrvPreFailMonitoring oid: 1.3.6.1.4.1.232.5.2.4.1.1.36 type: gauge help: SCSI Physical Drive Predictive Failure Monitoring - 1.3.6.1.4.1.232.5.2.4.1.1.36 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: notAvailable 3: available - name: cpqScsiPhyDrvOsName oid: 1.3.6.1.4.1.232.5.2.4.1.1.37 type: DisplayString help: Physical Drive OS Name - 1.3.6.1.4.1.232.5.2.4.1.1.37 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvRotationalSpeed oid: 1.3.6.1.4.1.232.5.2.4.1.1.38 type: gauge help: SCSI Physical Drive Rotational Speed - 1.3.6.1.4.1.232.5.2.4.1.1.38 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: rpm7200 3: rpm10K 4: rpm15K - name: cpqScsiPhyDrvMemberLogDrv oid: 1.3.6.1.4.1.232.5.2.4.1.1.39 type: gauge help: The Physical Drive is a Member of a Logical Drive - 1.3.6.1.4.1.232.5.2.4.1.1.39 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: member 3: spare 4: nonMember - name: cpqScsiTargetCntlrIndex oid: 1.3.6.1.4.1.232.5.2.5.1.1.1 type: gauge help: SCSI Target Controller Index - 1.3.6.1.4.1.232.5.2.5.1.1.1 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetBusIndex oid: 1.3.6.1.4.1.232.5.2.5.1.1.2 type: gauge help: SCSI Target Bus Index - 1.3.6.1.4.1.232.5.2.5.1.1.2 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetScsiIdIndex oid: 1.3.6.1.4.1.232.5.2.5.1.1.3 type: gauge help: SCSI Target Device Index - 1.3.6.1.4.1.232.5.2.5.1.1.3 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetType oid: 1.3.6.1.4.1.232.5.2.5.1.1.4 type: gauge help: SCSI Device Type - 1.3.6.1.4.1.232.5.2.5.1.1.4 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: disk 3: tape 4: printer 5: processor 6: wormDrive 7: cd-rom 8: scanner 9: optical 10: jukeBox 11: commDev - name: cpqScsiTargetModel oid: 1.3.6.1.4.1.232.5.2.5.1.1.5 type: DisplayString help: SCSI Device Model - 1.3.6.1.4.1.232.5.2.5.1.1.5 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetFWRev oid: 1.3.6.1.4.1.232.5.2.5.1.1.6 type: DisplayString help: SCSI Device Firmware Revision - 1.3.6.1.4.1.232.5.2.5.1.1.6 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetVendor oid: 1.3.6.1.4.1.232.5.2.5.1.1.7 type: DisplayString help: SCSI Device Vendor - 1.3.6.1.4.1.232.5.2.5.1.1.7 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetParityErrs oid: 1.3.6.1.4.1.232.5.2.5.1.1.8 type: counter help: SCSI Device Bus Parity Errors - 1.3.6.1.4.1.232.5.2.5.1.1.8 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetPhaseErrs oid: 1.3.6.1.4.1.232.5.2.5.1.1.9 type: counter help: SCSI Device Bus Phase Errors - 1.3.6.1.4.1.232.5.2.5.1.1.9 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetSelectTimeouts oid: 1.3.6.1.4.1.232.5.2.5.1.1.10 type: counter help: SCSI Device Bus Select Time-outs - 1.3.6.1.4.1.232.5.2.5.1.1.10 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetMsgRejects oid: 1.3.6.1.4.1.232.5.2.5.1.1.11 type: counter help: SCSI Device Bus Message Rejects - 1.3.6.1.4.1.232.5.2.5.1.1.11 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetNegPeriod oid: 1.3.6.1.4.1.232.5.2.5.1.1.12 type: gauge help: SCSI Device Negotiated Period - 1.3.6.1.4.1.232.5.2.5.1.1.12 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetLocation oid: 1.3.6.1.4.1.232.5.2.5.1.1.13 type: gauge help: SCSI Device Location - 1.3.6.1.4.1.232.5.2.5.1.1.13 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: proliant - name: cpqScsiTargetNegSpeed oid: 1.3.6.1.4.1.232.5.2.5.1.1.14 type: gauge help: SCSI Device Negotiated Speed - 1.3.6.1.4.1.232.5.2.5.1.1.14 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetPhysWidth oid: 1.3.6.1.4.1.232.5.2.5.1.1.15 type: gauge help: SCSI Device Data Bus Physical Width - 1.3.6.1.4.1.232.5.2.5.1.1.15 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: narrow 3: wide16 - name: cpqScsiTargetNegWidth oid: 1.3.6.1.4.1.232.5.2.5.1.1.16 type: gauge help: SCSI Device Data Bus Negotiated Width - 1.3.6.1.4.1.232.5.2.5.1.1.16 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetTypeExtended oid: 1.3.6.1.4.1.232.5.2.5.1.1.17 type: gauge help: SCSI Extended Device Type - 1.3.6.1.4.1.232.5.2.5.1.1.17 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: pdcd 3: removableDisk 4: dltAutoloader 5: cdJukebox 6: cr3500 7: autoloader - name: cpqScsiTargetCurrentSpeed oid: 1.3.6.1.4.1.232.5.2.5.1.1.18 type: gauge help: SCSI Device Current Data Transfer Speed - 1.3.6.1.4.1.232.5.2.5.1.1.18 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: asynchronous 3: fast 4: ultra 5: ultra2 6: ultra3 7: scsi1 8: ultra4 - name: cpqScsiCdDrvCntlrIndex oid: 1.3.6.1.4.1.232.5.2.6.1.1.1 type: gauge help: SCSI CD-ROM Drive Controller Index - 1.3.6.1.4.1.232.5.2.6.1.1.1 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvBusIndex oid: 1.3.6.1.4.1.232.5.2.6.1.1.2 type: gauge help: SCSI CD-ROM Drive Bus Index - 1.3.6.1.4.1.232.5.2.6.1.1.2 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvScsiIdIndex oid: 1.3.6.1.4.1.232.5.2.6.1.1.3 type: gauge help: SCSI CD-ROM Drive Index - 1.3.6.1.4.1.232.5.2.6.1.1.3 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvLunIndex oid: 1.3.6.1.4.1.232.5.2.6.1.1.4 type: gauge help: SCSI CD-ROM Drive Logical Unit Index - 1.3.6.1.4.1.232.5.2.6.1.1.4 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvModel oid: 1.3.6.1.4.1.232.5.2.6.1.1.5 type: DisplayString help: SCSI CD Device Model - 1.3.6.1.4.1.232.5.2.6.1.1.5 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvVendor oid: 1.3.6.1.4.1.232.5.2.6.1.1.6 type: DisplayString help: SCSI CD Drive Vendor - 1.3.6.1.4.1.232.5.2.6.1.1.6 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvFwRev oid: 1.3.6.1.4.1.232.5.2.6.1.1.7 type: DisplayString help: SCSI CD-ROM Firmware Revision - 1.3.6.1.4.1.232.5.2.6.1.1.7 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqCdLibraryCntlrIndex oid: 1.3.6.1.4.1.232.5.2.6.2.1.1 type: gauge help: SCSI CD Library Controller Index - 1.3.6.1.4.1.232.5.2.6.2.1.1 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryBusIndex oid: 1.3.6.1.4.1.232.5.2.6.2.1.2 type: gauge help: SCSI CD Library Bus Index - 1.3.6.1.4.1.232.5.2.6.2.1.2 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryScsiIdIndex oid: 1.3.6.1.4.1.232.5.2.6.2.1.3 type: gauge help: SCSI CD Library Device Index - 1.3.6.1.4.1.232.5.2.6.2.1.3 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryLunIndex oid: 1.3.6.1.4.1.232.5.2.6.2.1.4 type: gauge help: SCSI CD Library Logical Unit Index - 1.3.6.1.4.1.232.5.2.6.2.1.4 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryCondition oid: 1.3.6.1.4.1.232.5.2.6.2.1.5 type: gauge help: CD Library Condition - 1.3.6.1.4.1.232.5.2.6.2.1.5 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqCdLibraryStatus oid: 1.3.6.1.4.1.232.5.2.6.2.1.6 type: gauge help: CD Library Status - 1.3.6.1.4.1.232.5.2.6.2.1.6 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: offline - name: cpqCdLibraryModel oid: 1.3.6.1.4.1.232.5.2.6.2.1.7 type: DisplayString help: SCSI CD Library Device Model - 1.3.6.1.4.1.232.5.2.6.2.1.7 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryVendor oid: 1.3.6.1.4.1.232.5.2.6.2.1.8 type: DisplayString help: SCSI CD Library Vendor - 1.3.6.1.4.1.232.5.2.6.2.1.8 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibrarySerialNumber oid: 1.3.6.1.4.1.232.5.2.6.2.1.9 type: DisplayString help: CD Library Serial Number - 1.3.6.1.4.1.232.5.2.6.2.1.9 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryDriveList oid: 1.3.6.1.4.1.232.5.2.6.2.1.10 type: OctetString help: CD Library Drive List This is a data structure containing the list of CD drive ids that are present in this library - 1.3.6.1.4.1.232.5.2.6.2.1.10 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryFwRev oid: 1.3.6.1.4.1.232.5.2.6.2.1.11 type: DisplayString help: SCSI CD Library Firmware Revision - 1.3.6.1.4.1.232.5.2.6.2.1.11 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryFwSubtype oid: 1.3.6.1.4.1.232.5.2.6.2.1.12 type: gauge help: SCSI CD library Firmware Subtype - 1.3.6.1.4.1.232.5.2.6.2.1.12 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqScsiTrapPkts oid: 1.3.6.1.4.1.232.5.3.1 type: counter help: The total number of trap packets issued by the SCSI enterprise since the instrument agent was loaded. - 1.3.6.1.4.1.232.5.3.1 - name: cpqScsiTrapLogMaxSize oid: 1.3.6.1.4.1.232.5.3.2 type: gauge help: The maximum number of entries that will currently be kept in the trap log - 1.3.6.1.4.1.232.5.3.2 - name: cpqScsiTrapLogIndex oid: 1.3.6.1.4.1.232.5.3.3.1.1 type: gauge help: The value of this object uniquely identifies this trapLogEntry at this time - 1.3.6.1.4.1.232.5.3.3.1.1 indexes: - labelname: cpqScsiTrapLogIndex type: gauge - name: cpqScsiTrapType oid: 1.3.6.1.4.1.232.5.3.3.1.2 type: gauge help: The type of the trap event that this entry describes - 1.3.6.1.4.1.232.5.3.3.1.2 indexes: - labelname: cpqScsiTrapLogIndex type: gauge enum_values: 1: cpqScsiCntlrStatusChange 2: cpqScsiLogDrvStatusChange 3: cpqScsiPhyDrvStatusChange 5001: cpqScsi2CntlrStatusChange 5002: cpqScsi2LogDrvStatusChange 5003: cpqScsi2PhyDrvStatusChange - name: cpqScsiTrapTime oid: 1.3.6.1.4.1.232.5.3.3.1.3 type: OctetString help: The time of the trap event that this entry describes - 1.3.6.1.4.1.232.5.3.3.1.3 indexes: - labelname: cpqScsiTrapLogIndex type: gauge - name: cpqTapePhyDrvCntlrIndex oid: 1.3.6.1.4.1.232.5.4.1.1.1.1 type: gauge help: Tape Physical Drive Controller Index - 1.3.6.1.4.1.232.5.4.1.1.1.1 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvBusIndex oid: 1.3.6.1.4.1.232.5.4.1.1.1.2 type: gauge help: Tape Physical Drive Bus Index - 1.3.6.1.4.1.232.5.4.1.1.1.2 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvScsiIdIndex oid: 1.3.6.1.4.1.232.5.4.1.1.1.3 type: gauge help: Tape Physical Drive Index - 1.3.6.1.4.1.232.5.4.1.1.1.3 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvLunIndex oid: 1.3.6.1.4.1.232.5.4.1.1.1.4 type: gauge help: Tape Physical Drive Logical Unit Index - 1.3.6.1.4.1.232.5.4.1.1.1.4 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvType oid: 1.3.6.1.4.1.232.5.4.1.1.1.5 type: gauge help: Tape Device Type - 1.3.6.1.4.1.232.5.4.1.1.1.5 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: cpqDat4-16 3: cpqDatAuto 4: cpqDat2-8 5: cpqDlt10-20 6: cpqDlt20-40 7: cpqDlt15-30 8: cpqDlt35-70 9: cpqDat4-8 10: cpqSlr4-8 11: cpqDat12-24 12: cpqDatAuto12-24 13: cpqMlr16-32 14: cpqAit35 15: cpqAit50 16: cpqDat20-40 17: cpqDlt40-80 18: cpqDatAuto20-40 19: cpqSuperDlt1 20: cpqAit35Lvd 21: cpqCompaq - name: cpqTapePhyDrvCondition oid: 1.3.6.1.4.1.232.5.4.1.1.1.6 type: gauge help: Tape Physical Drive Status - 1.3.6.1.4.1.232.5.4.1.1.1.6 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqTapePhyDrvMagSize oid: 1.3.6.1.4.1.232.5.4.1.1.1.7 type: gauge help: Tape Physical Drive Magazine Size - 1.3.6.1.4.1.232.5.4.1.1.1.7 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvSerialNumber oid: 1.3.6.1.4.1.232.5.4.1.1.1.8 type: DisplayString help: Tape Physical Drive Serial Number - 1.3.6.1.4.1.232.5.4.1.1.1.8 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvCleanReq oid: 1.3.6.1.4.1.232.5.4.1.1.1.9 type: gauge help: Tape Physical Drive Cleaning Required Status - 1.3.6.1.4.1.232.5.4.1.1.1.9 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqTapePhyDrvCleanTapeRepl oid: 1.3.6.1.4.1.232.5.4.1.1.1.10 type: gauge help: Tape Physical Drive Cleaning Tape Replacement Status - 1.3.6.1.4.1.232.5.4.1.1.1.10 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqTapePhyDrvFwSubtype oid: 1.3.6.1.4.1.232.5.4.1.1.1.11 type: gauge help: Tape Physical Drive Firmware Subtype - 1.3.6.1.4.1.232.5.4.1.1.1.11 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvName oid: 1.3.6.1.4.1.232.5.4.1.1.1.12 type: DisplayString help: Tape Physical Drive Name - 1.3.6.1.4.1.232.5.4.1.1.1.12 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvCleanTapeCount oid: 1.3.6.1.4.1.232.5.4.1.1.1.13 type: gauge help: Tape Physical Drive Cleaning Tape Count - 1.3.6.1.4.1.232.5.4.1.1.1.13 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvFwRev oid: 1.3.6.1.4.1.232.5.4.1.1.1.14 type: DisplayString help: Tape Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.4.1.1.1.14 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvStatus oid: 1.3.6.1.4.1.232.5.4.1.1.1.15 type: gauge help: Tape Physical Drive Status - 1.3.6.1.4.1.232.5.4.1.1.1.15 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: ok 4: failed 5: offline 6: missingWasOk 7: missingWasFailed 8: missingWasOffline - name: cpqTapePhyDrvHotPlug oid: 1.3.6.1.4.1.232.5.4.1.1.1.16 type: gauge help: Tape Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.4.1.1.1.16 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: hotPlug 3: nonHotPlug - name: cpqTapePhyDrvPlacement oid: 1.3.6.1.4.1.232.5.4.1.1.1.17 type: gauge help: Tape Physical Drive Placement - 1.3.6.1.4.1.232.5.4.1.1.1.17 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: internal 3: external - name: cpqTapePhyDrvLibraryDrive oid: 1.3.6.1.4.1.232.5.4.1.1.1.18 type: gauge help: Tape Physical Drive Library Drive - 1.3.6.1.4.1.232.5.4.1.1.1.18 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqTapePhyDrvLoaderName oid: 1.3.6.1.4.1.232.5.4.1.1.1.19 type: DisplayString help: Tape Autoloader Name - 1.3.6.1.4.1.232.5.4.1.1.1.19 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvLoaderFwRev oid: 1.3.6.1.4.1.232.5.4.1.1.1.20 type: DisplayString help: Tape Autoloader Firmware Revision - 1.3.6.1.4.1.232.5.4.1.1.1.20 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvLoaderSerialNum oid: 1.3.6.1.4.1.232.5.4.1.1.1.21 type: DisplayString help: Tape Autoloader Serial Number - 1.3.6.1.4.1.232.5.4.1.1.1.21 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapeCountersCntlrIndex oid: 1.3.6.1.4.1.232.5.4.2.1.1.1 type: gauge help: SCSI Counters Controller Index - 1.3.6.1.4.1.232.5.4.2.1.1.1 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersBusIndex oid: 1.3.6.1.4.1.232.5.4.2.1.1.2 type: gauge help: SCSI Counters Bus Index - 1.3.6.1.4.1.232.5.4.2.1.1.2 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersScsiIdIndex oid: 1.3.6.1.4.1.232.5.4.2.1.1.3 type: gauge help: SCSI Counters Device Index - 1.3.6.1.4.1.232.5.4.2.1.1.3 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersLunIndex oid: 1.3.6.1.4.1.232.5.4.2.1.1.4 type: gauge help: SCSI Counters Logical Unit Index - 1.3.6.1.4.1.232.5.4.2.1.1.4 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersReWrites oid: 1.3.6.1.4.1.232.5.4.2.1.1.5 type: counter help: Tape Device Re-write count - 1.3.6.1.4.1.232.5.4.2.1.1.5 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersReReads oid: 1.3.6.1.4.1.232.5.4.2.1.1.6 type: counter help: Tape Device Re-read count - 1.3.6.1.4.1.232.5.4.2.1.1.6 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersTotalErrors oid: 1.3.6.1.4.1.232.5.4.2.1.1.7 type: counter help: Tape Device Total Errors - 1.3.6.1.4.1.232.5.4.2.1.1.7 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersTotalUncorrectable oid: 1.3.6.1.4.1.232.5.4.2.1.1.8 type: counter help: Tape Device Total Uncorrectable Errors - 1.3.6.1.4.1.232.5.4.2.1.1.8 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersTotalBytes oid: 1.3.6.1.4.1.232.5.4.2.1.1.9 type: counter help: Tape Device Total Bytes - 1.3.6.1.4.1.232.5.4.2.1.1.9 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeLibraryCntlrIndex oid: 1.3.6.1.4.1.232.5.4.3.1.1.1 type: gauge help: SCSI Library Controller Index - 1.3.6.1.4.1.232.5.4.3.1.1.1 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryBusIndex oid: 1.3.6.1.4.1.232.5.4.3.1.1.2 type: gauge help: SCSI Library Bus Index - 1.3.6.1.4.1.232.5.4.3.1.1.2 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryScsiIdIndex oid: 1.3.6.1.4.1.232.5.4.3.1.1.3 type: gauge help: SCSI Library Device Index - 1.3.6.1.4.1.232.5.4.3.1.1.3 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryLunIndex oid: 1.3.6.1.4.1.232.5.4.3.1.1.4 type: gauge help: SCSI Library Logical Unit Index - 1.3.6.1.4.1.232.5.4.3.1.1.4 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryCondition oid: 1.3.6.1.4.1.232.5.4.3.1.1.5 type: gauge help: Tape Library Status - 1.3.6.1.4.1.232.5.4.3.1.1.5 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqTapeLibraryStatus oid: 1.3.6.1.4.1.232.5.4.3.1.1.6 type: gauge help: Error code returned by the last library error. - 1.3.6.1.4.1.232.5.4.3.1.1.6 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryDoorStatus oid: 1.3.6.1.4.1.232.5.4.3.1.1.7 type: gauge help: Status of the library door - 1.3.6.1.4.1.232.5.4.3.1.1.7 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: closed 3: open 4: notSupported - name: cpqTapeLibraryStatHours oid: 1.3.6.1.4.1.232.5.4.3.1.1.8 type: counter help: The number of hours of operation for the library. - 1.3.6.1.4.1.232.5.4.3.1.1.8 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryStatMoves oid: 1.3.6.1.4.1.232.5.4.3.1.1.9 type: counter help: The number of tape moves for the library loader arm. - 1.3.6.1.4.1.232.5.4.3.1.1.9 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryName oid: 1.3.6.1.4.1.232.5.4.3.1.1.10 type: DisplayString help: Tape Library Name. - 1.3.6.1.4.1.232.5.4.3.1.1.10 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibrarySerialNumber oid: 1.3.6.1.4.1.232.5.4.3.1.1.11 type: DisplayString help: Tape Library Serial Number - 1.3.6.1.4.1.232.5.4.3.1.1.11 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryDriveList oid: 1.3.6.1.4.1.232.5.4.3.1.1.12 type: OctetString help: Tape Library Drive List This is a data structure containing the list of tape drive ids that are present in this library - 1.3.6.1.4.1.232.5.4.3.1.1.12 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryState oid: 1.3.6.1.4.1.232.5.4.3.1.1.13 type: gauge help: Tape Library Status - 1.3.6.1.4.1.232.5.4.3.1.1.13 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed 5: offline - name: cpqTapeLibraryTemperature oid: 1.3.6.1.4.1.232.5.4.3.1.1.14 type: gauge help: Tape Library Temperature Status - 1.3.6.1.4.1.232.5.4.3.1.1.14 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: notSupported 3: ok 4: safeTempExceeded 5: maxTempExceeded - name: cpqTapeLibraryRedundancy oid: 1.3.6.1.4.1.232.5.4.3.1.1.15 type: gauge help: Tape Library Redundancy Status - 1.3.6.1.4.1.232.5.4.3.1.1.15 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: notSupported 3: capable 4: notCapable 5: active - name: cpqTapeLibraryHotSwap oid: 1.3.6.1.4.1.232.5.4.3.1.1.16 type: gauge help: Tape Library Hot Swap Status - 1.3.6.1.4.1.232.5.4.3.1.1.16 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: notSupported 3: capable 4: notCapable - name: cpqTapeLibraryFwRev oid: 1.3.6.1.4.1.232.5.4.3.1.1.17 type: DisplayString help: Tape Library Firmware Revision - 1.3.6.1.4.1.232.5.4.3.1.1.17 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryTapeList oid: 1.3.6.1.4.1.232.5.4.3.1.1.18 type: OctetString help: Tape Library Drive List This is a data structure containing the list of tape drive ids that are present in this library - 1.3.6.1.4.1.232.5.4.3.1.1.18 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqSasHbaIndex oid: 1.3.6.1.4.1.232.5.5.1.1.1.1 type: gauge help: SAS Host Bus Adapter Index - 1.3.6.1.4.1.232.5.5.1.1.1.1 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaHwLocation oid: 1.3.6.1.4.1.232.5.5.1.1.1.2 type: DisplayString help: SAS Host Bus Adapter Hardware Location - 1.3.6.1.4.1.232.5.5.1.1.1.2 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaModel oid: 1.3.6.1.4.1.232.5.5.1.1.1.3 type: gauge help: SAS Host Bus Adapter Model - 1.3.6.1.4.1.232.5.5.1.1.1.3 indexes: - labelname: cpqSasHbaIndex type: gauge enum_values: 1: other 2: generic 3: sas8int 4: sas4int 5: sasSc44Ge 6: sasSc40Ge 7: sasSc08Ge 8: sasSc08e 9: sasH220i 10: sasH221 11: sasH210i 12: sasH220 13: sasH222 14: sasP824ip - name: cpqSasHbaStatus oid: 1.3.6.1.4.1.232.5.5.1.1.1.4 type: gauge help: SAS Host Bus Adapter Status - 1.3.6.1.4.1.232.5.5.1.1.1.4 indexes: - labelname: cpqSasHbaIndex type: gauge enum_values: 1: other 2: ok 3: failed - name: cpqSasHbaCondition oid: 1.3.6.1.4.1.232.5.5.1.1.1.5 type: gauge help: SAS Host Bus Adapter Condition - 1.3.6.1.4.1.232.5.5.1.1.1.5 indexes: - labelname: cpqSasHbaIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasHbaOverallCondition oid: 1.3.6.1.4.1.232.5.5.1.1.1.6 type: gauge help: SAS Host Bus Adapter Overall Condition - 1.3.6.1.4.1.232.5.5.1.1.1.6 indexes: - labelname: cpqSasHbaIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasHbaSerialNumber oid: 1.3.6.1.4.1.232.5.5.1.1.1.7 type: DisplayString help: SAS Host Bus Adapter Serial Number - 1.3.6.1.4.1.232.5.5.1.1.1.7 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaFwVersion oid: 1.3.6.1.4.1.232.5.5.1.1.1.8 type: DisplayString help: SAS Host Bus Adapter Firmware Version - 1.3.6.1.4.1.232.5.5.1.1.1.8 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaBiosVersion oid: 1.3.6.1.4.1.232.5.5.1.1.1.9 type: DisplayString help: SAS Host Bus Adapter BIOS Version - 1.3.6.1.4.1.232.5.5.1.1.1.9 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaPciLocation oid: 1.3.6.1.4.1.232.5.5.1.1.1.10 type: DisplayString help: SAS Host Bus Adapter PCI Location - 1.3.6.1.4.1.232.5.5.1.1.1.10 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasPhyDrvHbaIndex oid: 1.3.6.1.4.1.232.5.5.2.1.1.1 type: gauge help: SAS Physical Drive HBA Index - 1.3.6.1.4.1.232.5.5.2.1.1.1 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvIndex oid: 1.3.6.1.4.1.232.5.5.2.1.1.2 type: gauge help: SAS Physical Drive Index - 1.3.6.1.4.1.232.5.5.2.1.1.2 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvLocationString oid: 1.3.6.1.4.1.232.5.5.2.1.1.3 type: DisplayString help: SAS Physical Drive Location String - 1.3.6.1.4.1.232.5.5.2.1.1.3 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvModel oid: 1.3.6.1.4.1.232.5.5.2.1.1.4 type: DisplayString help: SAS Physical Drive Model - 1.3.6.1.4.1.232.5.5.2.1.1.4 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvStatus oid: 1.3.6.1.4.1.232.5.5.2.1.1.5 type: gauge help: SAS Physical Drive Status - 1.3.6.1.4.1.232.5.5.2.1.1.5 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: predictiveFailure 4: offline 5: failed 6: missingWasOk 7: missingWasPredictiveFailure 8: missingWasOffline 9: missingWasFailed 10: ssdWearOut 11: missingWasSSDWearOut 12: notAuthenticated 13: missingWasNotAuthenticated - name: cpqSasPhyDrvCondition oid: 1.3.6.1.4.1.232.5.5.2.1.1.6 type: gauge help: SAS Physical Drive Condition - 1.3.6.1.4.1.232.5.5.2.1.1.6 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasPhyDrvFWRev oid: 1.3.6.1.4.1.232.5.5.2.1.1.7 type: DisplayString help: SAS Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.7 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSize oid: 1.3.6.1.4.1.232.5.5.2.1.1.8 type: gauge help: SAS Physical Drive Size in MB - 1.3.6.1.4.1.232.5.5.2.1.1.8 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvUsedReallocs oid: 1.3.6.1.4.1.232.5.5.2.1.1.9 type: counter help: SAS Physical Drive Used Reallocation Sectors - 1.3.6.1.4.1.232.5.5.2.1.1.9 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSerialNumber oid: 1.3.6.1.4.1.232.5.5.2.1.1.10 type: DisplayString help: SAS Physical Drive Serial Number - 1.3.6.1.4.1.232.5.5.2.1.1.10 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvMemberLogDrv oid: 1.3.6.1.4.1.232.5.5.2.1.1.11 type: gauge help: The Physical Drive is a Member of a Logical Drive - 1.3.6.1.4.1.232.5.5.2.1.1.11 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: member 3: spare 4: nonMember - name: cpqSasPhyDrvRotationalSpeed oid: 1.3.6.1.4.1.232.5.5.2.1.1.12 type: gauge help: SAS Physical Drive Rotational Speed - 1.3.6.1.4.1.232.5.5.2.1.1.12 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: rpm7200 3: rpm10K 4: rpm15K 5: rpmSsd - name: cpqSasPhyDrvOsName oid: 1.3.6.1.4.1.232.5.5.2.1.1.13 type: DisplayString help: SAS Physical Drive OS Name - 1.3.6.1.4.1.232.5.5.2.1.1.13 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvPlacement oid: 1.3.6.1.4.1.232.5.5.2.1.1.14 type: gauge help: SAS Physical Drive Placement - 1.3.6.1.4.1.232.5.5.2.1.1.14 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: internal 3: external - name: cpqSasPhyDrvHotPlug oid: 1.3.6.1.4.1.232.5.5.2.1.1.15 type: gauge help: SAS Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.5.2.1.1.15 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: hotPlug 3: nonHotPlug - name: cpqSasPhyDrvType oid: 1.3.6.1.4.1.232.5.5.2.1.1.16 type: gauge help: SAS Physical Drive Type - 1.3.6.1.4.1.232.5.5.2.1.1.16 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: sas 3: sata - name: cpqSasPhyDrvSasAddress oid: 1.3.6.1.4.1.232.5.5.2.1.1.17 type: DisplayString help: SAS Physical Drive SAS Address - 1.3.6.1.4.1.232.5.5.2.1.1.17 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvMediaType oid: 1.3.6.1.4.1.232.5.5.2.1.1.18 type: gauge help: SAS Physical Drive Media Type - 1.3.6.1.4.1.232.5.5.2.1.1.18 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: rotatingPlatters 3: solidState - name: cpqSasPhyDrvSSDWearStatus oid: 1.3.6.1.4.1.232.5.5.2.1.1.19 type: gauge help: SAS Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.5.5.2.1.1.19 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: fiftySixDayThreshold 4: fivePercentThreshold 5: twoPercentThreshold 6: ssdWearOut - name: cpqSasPhyDrvPowerOnHours oid: 1.3.6.1.4.1.232.5.5.2.1.1.20 type: counter help: SAS Physical Drive Power On Hours - 1.3.6.1.4.1.232.5.5.2.1.1.20 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSSDPercntEndrnceUsed oid: 1.3.6.1.4.1.232.5.5.2.1.1.21 type: gauge help: SAS Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.5.5.2.1.1.21 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSSDEstTimeRemainingHours oid: 1.3.6.1.4.1.232.5.5.2.1.1.22 type: counter help: SAS Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.5.5.2.1.1.22 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvAuthenticationStatus oid: 1.3.6.1.4.1.232.5.5.2.1.1.23 type: gauge help: SAS Physical Drive Authentication Status - 1.3.6.1.4.1.232.5.5.2.1.1.23 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: notSupported 3: authenticationFailed 4: authenticationPassed - name: cpqSasPhyDrvSmartCarrierAppFWRev oid: 1.3.6.1.4.1.232.5.5.2.1.1.24 type: gauge help: SAS Physical Drive Smart Carrier Application Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.24 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSmartCarrierBootldrFWRev oid: 1.3.6.1.4.1.232.5.5.2.1.1.25 type: gauge help: SAS Physical Drive Smart Carrier Bootloader Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.25 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvCurrTemperature oid: 1.3.6.1.4.1.232.5.5.2.1.1.26 type: gauge help: SAS Physical Drive Current Operating Temperature degrees Celsius - 1.3.6.1.4.1.232.5.5.2.1.1.26 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvTemperatureThreshold oid: 1.3.6.1.4.1.232.5.5.2.1.1.27 type: gauge help: SAS Physical Drive Maximum Operating Temperature in degrees Celsius - 1.3.6.1.4.1.232.5.5.2.1.1.27 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSsBoxModel oid: 1.3.6.1.4.1.232.5.5.2.1.1.28 type: DisplayString help: SAS Physical Drive Box Model - 1.3.6.1.4.1.232.5.5.2.1.1.28 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSsBoxFwRev oid: 1.3.6.1.4.1.232.5.5.2.1.1.29 type: DisplayString help: SAS Physical Drive Box Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.29 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSsBoxVendor oid: 1.3.6.1.4.1.232.5.5.2.1.1.30 type: DisplayString help: SAS Physical Drive Box Vendor This is the SAS drive box`s vendor name - 1.3.6.1.4.1.232.5.5.2.1.1.30 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSsBoxSerialNumber oid: 1.3.6.1.4.1.232.5.5.2.1.1.31 type: DisplayString help: SAS Physical Drive Box Serial Number - 1.3.6.1.4.1.232.5.5.2.1.1.31 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasLogDrvHbaIndex oid: 1.3.6.1.4.1.232.5.5.3.1.1.1 type: gauge help: SAS Logical Drive HBA Index - 1.3.6.1.4.1.232.5.5.3.1.1.1 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvIndex oid: 1.3.6.1.4.1.232.5.5.3.1.1.2 type: gauge help: SAS Logical Drive Index - 1.3.6.1.4.1.232.5.5.3.1.1.2 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvRaidLevel oid: 1.3.6.1.4.1.232.5.5.3.1.1.3 type: gauge help: SAS Logical Drive RAID Level - 1.3.6.1.4.1.232.5.5.3.1.1.3 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge enum_values: 1: other 2: raid0 3: raid1 4: raid0plus1 5: raid5 6: raid15 7: volume - name: cpqSasLogDrvStatus oid: 1.3.6.1.4.1.232.5.5.3.1.1.4 type: gauge help: SAS Logical Drive Status - 1.3.6.1.4.1.232.5.5.3.1.1.4 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: rebuilding 5: failed 6: offline - name: cpqSasLogDrvCondition oid: 1.3.6.1.4.1.232.5.5.3.1.1.5 type: gauge help: SAS Logical Drive Condition - 1.3.6.1.4.1.232.5.5.3.1.1.5 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasLogDrvRebuildingDisk oid: 1.3.6.1.4.1.232.5.5.3.1.1.6 type: gauge help: SAS Logical Drive Rebuilding Disk - 1.3.6.1.4.1.232.5.5.3.1.1.6 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvCapacity oid: 1.3.6.1.4.1.232.5.5.3.1.1.7 type: gauge help: SAS Logical Drive Size - 1.3.6.1.4.1.232.5.5.3.1.1.7 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvStripeSize oid: 1.3.6.1.4.1.232.5.5.3.1.1.8 type: gauge help: SAS Logical Drive Stripe Size - 1.3.6.1.4.1.232.5.5.3.1.1.8 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvPhyDrvIds oid: 1.3.6.1.4.1.232.5.5.3.1.1.9 type: OctetString help: SAS Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.5.5.3.1.1.9 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvSpareIds oid: 1.3.6.1.4.1.232.5.5.3.1.1.10 type: OctetString help: SAS Logical Drive Spare Drive IDs - 1.3.6.1.4.1.232.5.5.3.1.1.10 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvOsName oid: 1.3.6.1.4.1.232.5.5.3.1.1.11 type: DisplayString help: SAS Logical Drive OS Name - 1.3.6.1.4.1.232.5.5.3.1.1.11 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvRebuildingPercent oid: 1.3.6.1.4.1.232.5.5.3.1.1.12 type: gauge help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.5.5.3.1.1.12 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasTapeDrvHbaIndex oid: 1.3.6.1.4.1.232.5.5.4.1.1.1 type: gauge help: SAS Tape Drive HBA Index - 1.3.6.1.4.1.232.5.5.4.1.1.1 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvIndex oid: 1.3.6.1.4.1.232.5.5.4.1.1.2 type: gauge help: SAS Tape Drive Index - 1.3.6.1.4.1.232.5.5.4.1.1.2 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvLocationString oid: 1.3.6.1.4.1.232.5.5.4.1.1.3 type: DisplayString help: SAS Tape Drive Location String - 1.3.6.1.4.1.232.5.5.4.1.1.3 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvName oid: 1.3.6.1.4.1.232.5.5.4.1.1.4 type: DisplayString help: SAS Tape Drive Name - 1.3.6.1.4.1.232.5.5.4.1.1.4 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvStatus oid: 1.3.6.1.4.1.232.5.5.4.1.1.5 type: gauge help: SAS Physical Drive Status - 1.3.6.1.4.1.232.5.5.4.1.1.5 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge enum_values: 1: other 2: ok 3: offline - name: cpqSasTapeDrvCondition oid: 1.3.6.1.4.1.232.5.5.4.1.1.6 type: gauge help: SAS Tape Drive Condition - 1.3.6.1.4.1.232.5.5.4.1.1.6 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasTapeDrvFWRev oid: 1.3.6.1.4.1.232.5.5.4.1.1.7 type: DisplayString help: SAS Tape Drive Firmware Revision - 1.3.6.1.4.1.232.5.5.4.1.1.7 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvSerialNumber oid: 1.3.6.1.4.1.232.5.5.4.1.1.8 type: DisplayString help: SAS Tape Drive Serial Number - 1.3.6.1.4.1.232.5.5.4.1.1.8 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvSasAddress oid: 1.3.6.1.4.1.232.5.5.4.1.1.9 type: DisplayString help: SAS Tape Drive SAS Address - 1.3.6.1.4.1.232.5.5.4.1.1.9 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqHeResMem2ModuleSize oid: 1.3.6.1.4.1.232.6.2.14.13.1.6 type: gauge help: Module memory size in kilobytes - 1.3.6.1.4.1.232.6.2.14.13.1.6 indexes: - labelname: cpqHeResMem2Module type: gauge - name: cpqHePowerMeterSupport oid: 1.3.6.1.4.1.232.6.2.15.1 type: gauge help: This value specifies whether Power Meter is supported by this Server - 1.3.6.1.4.1.232.6.2.15.1 enum_values: 1: other 2: supported 3: unsupported - name: cpqHePowerMeterStatus oid: 1.3.6.1.4.1.232.6.2.15.2 type: gauge help: This value specifies whether Power Meter reading is supported by this Server - 1.3.6.1.4.1.232.6.2.15.2 enum_values: 1: other 2: present 3: absent - name: cpqHePowerMeterCurrReading oid: 1.3.6.1.4.1.232.6.2.15.3 type: gauge help: This is the current Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.3 - name: cpqHePowerMeterPrevReading oid: 1.3.6.1.4.1.232.6.2.15.4 type: gauge help: This is the previous Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.4 - name: cpqHeHWBiosCondition oid: 1.3.6.1.4.1.232.6.2.16.1 type: gauge help: This value indicates an error has been detected during Pre-OS Test (POST) or during initial hardware initialization - 1.3.6.1.4.1.232.6.2.16.1 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeSysBackupBatteryCondition oid: 1.3.6.1.4.1.232.6.2.17.1 type: gauge help: This value specifies the overall condition of the battery backup sub-system. - 1.3.6.1.4.1.232.6.2.17.1 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeSysBatteryChassis oid: 1.3.6.1.4.1.232.6.2.17.2.1.1 type: gauge help: The system chassis number. - 1.3.6.1.4.1.232.6.2.17.2.1.1 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryIndex oid: 1.3.6.1.4.1.232.6.2.17.2.1.2 type: gauge help: The battery index number within this chassis. - 1.3.6.1.4.1.232.6.2.17.2.1.2 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryPresent oid: 1.3.6.1.4.1.232.6.2.17.2.1.3 type: gauge help: Indicates whether the backup battery is present in the chassis. - 1.3.6.1.4.1.232.6.2.17.2.1.3 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge enum_values: 1: other 2: absent 3: present - name: cpqHeSysBatteryCondition oid: 1.3.6.1.4.1.232.6.2.17.2.1.4 type: gauge help: The condition of the backup battery - 1.3.6.1.4.1.232.6.2.17.2.1.4 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeSysBatteryStatus oid: 1.3.6.1.4.1.232.6.2.17.2.1.5 type: gauge help: The status of the battery. - 1.3.6.1.4.1.232.6.2.17.2.1.5 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge enum_values: 1: noError 2: generalFailure 3: shutdownHighResistance 4: shutdownLowVoltage 5: shutdownShortCircuit 6: shutdownChargeTimeout 7: shutdownOverTemperature 8: shutdownDischargeMinVoltage 9: shutdownDischargeCurrent 10: shutdownLoadCountHigh 11: shutdownEnablePin 12: shutdownOverCurrent 13: shutdownPermanentFailure 14: shutdownBackupTimeExceeded 15: predictiveFailure - name: cpqHeSysBatteryCapacityMaximum oid: 1.3.6.1.4.1.232.6.2.17.2.1.6 type: gauge help: The maximum capacity of the battery in watts. - 1.3.6.1.4.1.232.6.2.17.2.1.6 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryProductName oid: 1.3.6.1.4.1.232.6.2.17.2.1.7 type: DisplayString help: The battery product name. - 1.3.6.1.4.1.232.6.2.17.2.1.7 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryModel oid: 1.3.6.1.4.1.232.6.2.17.2.1.8 type: DisplayString help: The battery model name. - 1.3.6.1.4.1.232.6.2.17.2.1.8 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatterySerialNumber oid: 1.3.6.1.4.1.232.6.2.17.2.1.9 type: DisplayString help: The battery serial number. - 1.3.6.1.4.1.232.6.2.17.2.1.9 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryFirmwareRev oid: 1.3.6.1.4.1.232.6.2.17.2.1.10 type: DisplayString help: The battery firmware revision - 1.3.6.1.4.1.232.6.2.17.2.1.10 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatterySparePartNum oid: 1.3.6.1.4.1.232.6.2.17.2.1.11 type: DisplayString help: The battery part number or spare part number. - 1.3.6.1.4.1.232.6.2.17.2.1.11 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeTemperatureChassis oid: 1.3.6.1.4.1.232.6.2.6.8.1.1 type: gauge help: The System Chassis number. - 1.3.6.1.4.1.232.6.2.6.8.1.1 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeTemperatureIndex oid: 1.3.6.1.4.1.232.6.2.6.8.1.2 type: gauge help: A number that uniquely specifies this temperature sensor description. - 1.3.6.1.4.1.232.6.2.6.8.1.2 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeTemperatureLocale oid: 1.3.6.1.4.1.232.6.2.6.8.1.3 type: EnumAsInfo help: This specifies the location of the temperature sensor present in the system. - 1.3.6.1.4.1.232.6.2.6.8.1.3 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge enum_values: 1: other 2: unknown 3: system 4: systemBoard 5: ioBoard 6: cpu 7: memory 8: storage 9: removableMedia 10: powerSupply 11: ambient 12: chassis 13: bridgeCard - name: cpqHeTemperatureCelsius oid: 1.3.6.1.4.1.232.6.2.6.8.1.4 type: gauge help: This is the current temperature sensor reading in degrees celsius - 1.3.6.1.4.1.232.6.2.6.8.1.4 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeTemperatureThreshold oid: 1.3.6.1.4.1.232.6.2.6.8.1.5 type: gauge help: This is the shutdown threshold temperature sensor setting in degrees celsius - 1.3.6.1.4.1.232.6.2.6.8.1.5 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeTemperatureCondition oid: 1.3.6.1.4.1.232.6.2.6.8.1.6 type: gauge help: The Temperature sensor condition - 1.3.6.1.4.1.232.6.2.6.8.1.6 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeTemperatureThresholdType oid: 1.3.6.1.4.1.232.6.2.6.8.1.7 type: gauge help: This specifies the type of this instance of temperature sensor - 1.3.6.1.4.1.232.6.2.6.8.1.7 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge enum_values: 1: other 5: blowout 9: caution 15: critical 16: noreaction - name: cpqHeTemperatureHwLocation oid: 1.3.6.1.4.1.232.6.2.6.8.1.8 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the temperature sensor - 1.3.6.1.4.1.232.6.2.6.8.1.8 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeFltTolPwrSupplyCondition oid: 1.3.6.1.4.1.232.6.2.9.1 type: gauge help: This value specifies the overall condition of the fault tolerant power supply sub-system. - 1.3.6.1.4.1.232.6.2.9.1 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeFltTolPwrSupplyStatus oid: 1.3.6.1.4.1.232.6.2.9.2 type: gauge help: This value specifies the status of the fault tolerant power supply. - 1.3.6.1.4.1.232.6.2.9.2 enum_values: 1: other 2: notSupported 3: notInstalled 4: installed - name: cpqHeFltTolPowerSupplyChassis oid: 1.3.6.1.4.1.232.6.2.9.3.1.1 type: gauge help: The system chassis number. - 1.3.6.1.4.1.232.6.2.9.3.1.1 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyBay oid: 1.3.6.1.4.1.232.6.2.9.3.1.2 type: gauge help: The bay number to index within this chassis. - 1.3.6.1.4.1.232.6.2.9.3.1.2 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyPresent oid: 1.3.6.1.4.1.232.6.2.9.3.1.3 type: gauge help: Indicates whether the power supply is present in the chassis. - 1.3.6.1.4.1.232.6.2.9.3.1.3 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: other 2: absent 3: present - name: cpqHeFltTolPowerSupplyCondition oid: 1.3.6.1.4.1.232.6.2.9.3.1.4 type: gauge help: The condition of the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.4 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeFltTolPowerSupplyStatus oid: 1.3.6.1.4.1.232.6.2.9.3.1.5 type: gauge help: The status of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.5 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: noError 2: generalFailure 3: bistFailure 4: fanFailure 5: tempFailure 6: interlockOpen 7: epromFailed 8: vrefFailed 9: dacFailed 10: ramTestFailed 11: voltageChannelFailed 12: orringdiodeFailed 13: brownOut 14: giveupOnStartup 15: nvramInvalid 16: calibrationTableInvalid 17: noPowerInput - name: cpqHeFltTolPowerSupplyMainVoltage oid: 1.3.6.1.4.1.232.6.2.9.3.1.6 type: gauge help: The input main voltage of the power supply in volts. - 1.3.6.1.4.1.232.6.2.9.3.1.6 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyCapacityUsed oid: 1.3.6.1.4.1.232.6.2.9.3.1.7 type: gauge help: The currently used capacity of the power supply in watts. - 1.3.6.1.4.1.232.6.2.9.3.1.7 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyCapacityMaximum oid: 1.3.6.1.4.1.232.6.2.9.3.1.8 type: gauge help: The maximum capacity of the power supply in watts. - 1.3.6.1.4.1.232.6.2.9.3.1.8 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyRedundant oid: 1.3.6.1.4.1.232.6.2.9.3.1.9 type: gauge help: The redundancy state of the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.9 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: other 2: notRedundant 3: redundant - name: cpqHeFltTolPowerSupplyModel oid: 1.3.6.1.4.1.232.6.2.9.3.1.10 type: DisplayString help: The power supply model name. - 1.3.6.1.4.1.232.6.2.9.3.1.10 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplySerialNumber oid: 1.3.6.1.4.1.232.6.2.9.3.1.11 type: DisplayString help: The power supply serial number. - 1.3.6.1.4.1.232.6.2.9.3.1.11 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyAutoRev oid: 1.3.6.1.4.1.232.6.2.9.3.1.12 type: OctetString help: The power supply auto revision number. - 1.3.6.1.4.1.232.6.2.9.3.1.12 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyHotPlug oid: 1.3.6.1.4.1.232.6.2.9.3.1.13 type: gauge help: This indicates if the power supply is capable of being removed and/or inserted while the system is in an operational state - 1.3.6.1.4.1.232.6.2.9.3.1.13 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: other 2: nonHotPluggable 3: hotPluggable - name: cpqHeFltTolPowerSupplyFirmwareRev oid: 1.3.6.1.4.1.232.6.2.9.3.1.14 type: DisplayString help: The power supply firmware revision - 1.3.6.1.4.1.232.6.2.9.3.1.14 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyHwLocation oid: 1.3.6.1.4.1.232.6.2.9.3.1.15 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.15 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplySparePartNum oid: 1.3.6.1.4.1.232.6.2.9.3.1.16 type: DisplayString help: The power supply part number or spare part number. - 1.3.6.1.4.1.232.6.2.9.3.1.16 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyRedundantPartner oid: 1.3.6.1.4.1.232.6.2.9.3.1.17 type: gauge help: This specifies the index of the redundant partner - 1.3.6.1.4.1.232.6.2.9.3.1.17 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyErrorCondition oid: 1.3.6.1.4.1.232.6.2.9.3.1.18 type: gauge help: The Error condition of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.18 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: noError 2: generalFailure 3: overvoltage 4: overcurrent 5: overtemperature 6: powerinputloss 7: fanfailure 8: vinhighwarning 9: vinlowwarning 10: vouthighwarning 11: voutlowwarning 12: inlettemphighwarning 13: iinternaltemphighwarning 14: vauxhighwarning 15: vauxlowwarning 16: powersupplymismatch 17: goodinstandby - name: cpqSm2CntlrRomDate oid: 1.3.6.1.4.1.232.9.2.2.1 type: DisplayString help: Remote Insight/ Integrated Lights-Out ROM Date - 1.3.6.1.4.1.232.9.2.2.1 - name: cpqSm2CntlrRomRevision oid: 1.3.6.1.4.1.232.9.2.2.2 type: DisplayString help: Remote Insight/ Integrated Lights-Out ROM Revision - 1.3.6.1.4.1.232.9.2.2.2 - name: cpqSm2CntlrVideoStatus oid: 1.3.6.1.4.1.232.9.2.2.3 type: gauge help: Remote Insight/ Integrated Lights-Out Video Hardware Status - 1.3.6.1.4.1.232.9.2.2.3 enum_values: 1: other 2: enabled 3: disabled - name: cpqSm2CntlrBatteryEnabled oid: 1.3.6.1.4.1.232.9.2.2.4 type: gauge help: Remote Insight Battery Enabled - 1.3.6.1.4.1.232.9.2.2.4 enum_values: 1: other 2: enabled 3: disabled 4: noBattery - name: cpqSm2CntlrBatteryStatus oid: 1.3.6.1.4.1.232.9.2.2.5 type: gauge help: Remote Insight Battery Status - 1.3.6.1.4.1.232.9.2.2.5 enum_values: 1: other 2: batteryOk 3: batteryFailed 4: batteryDisconnected - name: cpqSm2CntlrBatteryPercentCharged oid: 1.3.6.1.4.1.232.9.2.2.6 type: gauge help: Remote Insight Battery Percent Charged - 1.3.6.1.4.1.232.9.2.2.6 - name: cpqSm2CntlrAlertStatus oid: 1.3.6.1.4.1.232.9.2.2.7 type: gauge help: Remote Insight/ Integrated Lights-Out Alerting Status - 1.3.6.1.4.1.232.9.2.2.7 enum_values: 1: other 2: enabled 3: disabled - name: cpqSm2CntlrPendingAlerts oid: 1.3.6.1.4.1.232.9.2.2.8 type: gauge help: Pending Remote Insight/ Integrated Lights-Out alerts - 1.3.6.1.4.1.232.9.2.2.8 enum_values: 1: other 2: noAlertsPending 3: alertsPending 4: clearPendingAlerts - name: cpqSm2CntlrSelfTestErrors oid: 1.3.6.1.4.1.232.9.2.2.9 type: gauge help: Remote Insight/ Integrated Lights-Out Self Test Errors - 1.3.6.1.4.1.232.9.2.2.9 - name: cpqSm2CntlrAgentLocation oid: 1.3.6.1.4.1.232.9.2.2.10 type: gauge help: Remote Insight/ Integrated Lights-Out Agent Location - 1.3.6.1.4.1.232.9.2.2.10 enum_values: 1: hostOsAgent 2: firmwareAgent 3: remoteInsightPciFirmwareAgent 4: enclosureFirmwareAgent - name: cpqSm2CntlrLastDataUpdate oid: 1.3.6.1.4.1.232.9.2.2.11 type: OctetString help: The date and time that the Remote Insight/ Integrated Lights-Out offline data was last updated - 1.3.6.1.4.1.232.9.2.2.11 - name: cpqSm2CntlrDataStatus oid: 1.3.6.1.4.1.232.9.2.2.12 type: gauge help: Remote Insight/ Integrated Lights-Out Host OS Data Status - 1.3.6.1.4.1.232.9.2.2.12 enum_values: 1: other 2: noData 3: onlineData 4: offlineData - name: cpqSm2CntlrColdReboot oid: 1.3.6.1.4.1.232.9.2.2.13 type: gauge help: 'Remote Insight/ Integrated Lights-Out Server Cold Reboot The following values are defined: notAvailable(1) Cold reboot of the system is not available - 1.3.6.1.4.1.232.9.2.2.13' enum_values: 1: notAvailable 2: available 3: doColdReboot - name: cpqSm2CntlrBadLoginAttemptsThresh oid: 1.3.6.1.4.1.232.9.2.2.14 type: gauge help: Maximum Unauthorized Login Attempts Threshold - 1.3.6.1.4.1.232.9.2.2.14 - name: cpqSm2CntlrBoardSerialNumber oid: 1.3.6.1.4.1.232.9.2.2.15 type: DisplayString help: Remote Insight/ Integrated Lights-Out Serial Number - 1.3.6.1.4.1.232.9.2.2.15 - name: cpqSm2CntlrRemoteSessionStatus oid: 1.3.6.1.4.1.232.9.2.2.16 type: gauge help: Remote Insight/ Integrated Lights-Out Session Status - 1.3.6.1.4.1.232.9.2.2.16 enum_values: 1: other 2: active 3: inactive - name: cpqSm2CntlrInterfaceStatus oid: 1.3.6.1.4.1.232.9.2.2.17 type: gauge help: Remote Insight/ Integrated Lights-Out Interface Status - 1.3.6.1.4.1.232.9.2.2.17 enum_values: 1: other 2: ok 3: notResponding - name: cpqSm2CntlrSystemId oid: 1.3.6.1.4.1.232.9.2.2.18 type: DisplayString help: Remote Insight/ Integrated Lights-Out System ID - 1.3.6.1.4.1.232.9.2.2.18 - name: cpqSm2CntlrKeyboardCableStatus oid: 1.3.6.1.4.1.232.9.2.2.19 type: gauge help: Remote Insight Keyboard Cable Status - 1.3.6.1.4.1.232.9.2.2.19 enum_values: 1: other 2: connected 3: disconnected - name: cpqSm2ServerIpAddress oid: 1.3.6.1.4.1.232.9.2.2.20 type: InetAddressIPv4 help: The IP address for this servers connection to the Remote Insight/ Integrated Lights-Out - 1.3.6.1.4.1.232.9.2.2.20 - name: cpqSm2CntlrModel oid: 1.3.6.1.4.1.232.9.2.2.21 type: gauge help: Remote Insight/ Integrated Lights-Out Model - 1.3.6.1.4.1.232.9.2.2.21 enum_values: 1: other 2: eisaRemoteInsightBoard 3: pciRemoteInsightBoard 4: pciLightsOutRemoteInsightBoard 5: pciIntegratedLightsOutRemoteInsight 6: pciLightsOutRemoteInsightBoardII 7: pciIntegratedLightsOutRemoteInsight2 8: pciLightsOut100series 9: pciIntegratedLightsOutRemoteInsight3 10: pciIntegratedLightsOutRemoteInsight4 11: pciIntegratedLightsOutRemoteInsight5 - name: cpqSm2CntlrSelfTestErrorMask oid: 1.3.6.1.4.1.232.9.2.2.22 type: gauge help: Remote Insight/ Integrated Lights-Out Self Test Error Mask - 1.3.6.1.4.1.232.9.2.2.22 - name: cpqSm2CntlrMouseCableStatus oid: 1.3.6.1.4.1.232.9.2.2.23 type: gauge help: Remote Insight Mouse Cable Status - 1.3.6.1.4.1.232.9.2.2.23 enum_values: 1: other 2: connected 3: disconnected - name: cpqSm2CntlrVirtualPowerCableStatus oid: 1.3.6.1.4.1.232.9.2.2.24 type: gauge help: Remote Insight Virtual Power Cable Status - 1.3.6.1.4.1.232.9.2.2.24 enum_values: 1: other 2: connected 3: disconnected 4: notApplicable - name: cpqSm2CntlrExternalPowerCableStatus oid: 1.3.6.1.4.1.232.9.2.2.25 type: gauge help: Remote Insight External Power Cable Status - 1.3.6.1.4.1.232.9.2.2.25 enum_values: 1: other 2: externallyConnected 3: disconnected 4: internallyConnected 5: externallyAndInternallyConnected 6: notApplicable - name: cpqSm2CntlrHostGUID oid: 1.3.6.1.4.1.232.9.2.2.26 type: OctetString help: The globally unique identifier of this server - 1.3.6.1.4.1.232.9.2.2.26 - name: cpqSm2CntlriLOSecurityOverrideSwitchState oid: 1.3.6.1.4.1.232.9.2.2.27 type: gauge help: Integrated Lights-Out Security Override Switch State - 1.3.6.1.4.1.232.9.2.2.27 enum_values: 1: notSupported 2: set 3: notSet - name: cpqSm2CntlrHardwareVer oid: 1.3.6.1.4.1.232.9.2.2.28 type: gauge help: Hardware Version of Remote Insight/ Integrated Lights-Out. - 1.3.6.1.4.1.232.9.2.2.28 - name: cpqSm2CntlrAction oid: 1.3.6.1.4.1.232.9.2.2.29 type: gauge help: Remote Insight/ Integrated Lights-Out Action Flags - 1.3.6.1.4.1.232.9.2.2.29 - name: cpqSm2CntlrLicenseActive oid: 1.3.6.1.4.1.232.9.2.2.30 type: gauge help: Remote Insight License State - 1.3.6.1.4.1.232.9.2.2.30 enum_values: 1: none 2: iloAdvanced 3: iloLight 4: iloAdvancedBlade 5: iloStandard 6: iloEssentials 7: iloScaleOut 8: iloAdvancedPremiumSecurity - name: cpqSm2CntlrLicenseKey oid: 1.3.6.1.4.1.232.9.2.2.31 type: DisplayString help: iLO Active ASCII License key string - 1.3.6.1.4.1.232.9.2.2.31 - name: cpqSm2CntlrServerPowerState oid: 1.3.6.1.4.1.232.9.2.2.32 type: gauge help: The current power state for the server - 1.3.6.1.4.1.232.9.2.2.32 enum_values: 1: unknown 2: poweredOff 3: poweredOn 4: insufficientPowerOrPowerOnDenied - name: cpqSm2CntlrSysAutoShutdownCause oid: 1.3.6.1.4.1.232.9.2.2.33 type: gauge help: Indicate the reason for triggering system auto shutdown or cancelling auto shutdown. - 1.3.6.1.4.1.232.9.2.2.33 enum_values: 1: fanFailure 2: overheatCondition 3: vrmFailure 4: powerSupplyFailure 5: systemRunningOnBatteryBackupUnit 129: aborted 130: fanFailureAborted 131: overheatAborted 132: vrmFailureAborted 133: softPowerDown 134: softwareAutomaticServerRecovery 135: powerSupplyFailureAborted - name: cpqSm2CntlrSecurityState oid: 1.3.6.1.4.1.232.9.2.2.34 type: gauge help: Indicate security state - 1.3.6.1.4.1.232.9.2.2.34 enum_values: 1: factory 2: wipe 3: production 4: highSecurity 5: fips 6: cnsa - name: cpqSm2WDTimerType oid: 1.3.6.1.4.1.232.9.2.2.35 type: gauge help: Indicate the watchdog timer type. - 1.3.6.1.4.1.232.9.2.2.35 enum_values: 1: unknown 2: ipmi - name: cpqSm2WDTimerTimeoutDetails oid: 1.3.6.1.4.1.232.9.2.2.36 type: DisplayString help: Indicate the watchdog timer timeout action and timer details. - 1.3.6.1.4.1.232.9.2.2.36 - name: cpqSm2CntlrOverallSecStatus oid: 1.3.6.1.4.1.232.9.2.2.37 type: gauge help: The field indicates the overall security status. - 1.3.6.1.4.1.232.9.2.2.37 enum_values: 1: Ok 2: Risk 3: Ignored version: 2 auth: community: public hpe_sim: walk: - 1.3.6.1.4.1.232.1.2.2.1.1 - 1.3.6.1.4.1.232.11 - 1.3.6.1.4.1.232.14 - 1.3.6.1.4.1.232.3.2.2.1 - 1.3.6.1.4.1.232.3.2.3.1.1 - 1.3.6.1.4.1.232.3.2.5.1.1 - 1.3.6.1.4.1.232.5 - 1.3.6.1.4.1.232.6.2.14.13.1.6 - 1.3.6.1.4.1.232.6.2.15 - 1.3.6.1.4.1.232.6.2.16 - 1.3.6.1.4.1.232.6.2.17 - 1.3.6.1.4.1.232.6.2.6.8.1 - 1.3.6.1.4.1.232.6.2.9 - 1.3.6.1.4.1.232.9.2.2 get: - 1.3.6.1.2.1.1.3.0 metrics: - name: sysUpTime oid: 1.3.6.1.2.1.1.3 type: gauge help: The time (in hundredths of a second) since the network management portion of the system was last re-initialized. - 1.3.6.1.2.1.1.3 - name: cpqSeCpuUnitIndex oid: 1.3.6.1.4.1.232.1.2.2.1.1.1 type: gauge help: This is a number that uniquely specifies a processor unit - 1.3.6.1.4.1.232.1.2.2.1.1.1 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuSlot oid: 1.3.6.1.4.1.232.1.2.2.1.1.2 type: gauge help: This value represents this processor`s slot - 1.3.6.1.4.1.232.1.2.2.1.1.2 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuName oid: 1.3.6.1.4.1.232.1.2.2.1.1.3 type: DisplayString help: The name of this processor - 1.3.6.1.4.1.232.1.2.2.1.1.3 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuSpeed oid: 1.3.6.1.4.1.232.1.2.2.1.1.4 type: gauge help: The current internal speed of this processor in megahertz - 1.3.6.1.4.1.232.1.2.2.1.1.4 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuStep oid: 1.3.6.1.4.1.232.1.2.2.1.1.5 type: gauge help: This step of the processor - 1.3.6.1.4.1.232.1.2.2.1.1.5 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuStatus oid: 1.3.6.1.4.1.232.1.2.2.1.1.6 type: gauge help: The status of the processor - 1.3.6.1.4.1.232.1.2.2.1.1.6 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: ok 3: degraded 4: failed 5: disabled - name: cpqSeCpuExtSpeed oid: 1.3.6.1.4.1.232.1.2.2.1.1.7 type: gauge help: This is the external frequency in megahertz of the processor bus - 1.3.6.1.4.1.232.1.2.2.1.1.7 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuDesigner oid: 1.3.6.1.4.1.232.1.2.2.1.1.8 type: gauge help: This attribute specifies the manufacturer which designs this CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.8 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: intel 3: amd 4: cyrix 5: ti 6: nexgen 7: compaq 8: samsung 9: mitsubishi 10: mips - name: cpqSeCpuSocketNumber oid: 1.3.6.1.4.1.232.1.2.2.1.1.9 type: gauge help: The physical socket number of the CPU chip - 1.3.6.1.4.1.232.1.2.2.1.1.9 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuThreshPassed oid: 1.3.6.1.4.1.232.1.2.2.1.1.10 type: gauge help: CPU threshold passed (Exceeded) - 1.3.6.1.4.1.232.1.2.2.1.1.10 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unsupported 2: "false" 3: "true" - name: cpqSeCpuHwLocation oid: 1.3.6.1.4.1.232.1.2.2.1.1.11 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the CPU - 1.3.6.1.4.1.232.1.2.2.1.1.11 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuCellTablePtr oid: 1.3.6.1.4.1.232.1.2.2.1.1.12 type: gauge help: This is the index for the cell in cpqSeCellTable where this CPU is physically located. - 1.3.6.1.4.1.232.1.2.2.1.1.12 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuPowerpodStatus oid: 1.3.6.1.4.1.232.1.2.2.1.1.13 type: gauge help: This is the status of CPU power pod - 1.3.6.1.4.1.232.1.2.2.1.1.13 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: notfailed 2: failed - name: cpqSeCpuArchitectureRevision oid: 1.3.6.1.4.1.232.1.2.2.1.1.14 type: DisplayString help: This is the CPU architecture revision. - 1.3.6.1.4.1.232.1.2.2.1.1.14 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuCore oid: 1.3.6.1.4.1.232.1.2.2.1.1.15 type: gauge help: The number of cores in this CPU module - 1.3.6.1.4.1.232.1.2.2.1.1.15 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUSerialNumber oid: 1.3.6.1.4.1.232.1.2.2.1.1.16 type: DisplayString help: The OEM serial number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.16 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUPartNumber oid: 1.3.6.1.4.1.232.1.2.2.1.1.17 type: DisplayString help: The OEM part number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.17 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUSerialNumberMfgr oid: 1.3.6.1.4.1.232.1.2.2.1.1.18 type: DisplayString help: The manufacturer serial number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.18 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUPartNumberMfgr oid: 1.3.6.1.4.1.232.1.2.2.1.1.19 type: DisplayString help: The manufacturer part number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.19 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUCoreIndex oid: 1.3.6.1.4.1.232.1.2.2.1.1.20 type: gauge help: This is a number that uniquely identifies a core in a CPU unit. - 1.3.6.1.4.1.232.1.2.2.1.1.20 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUMaxSpeed oid: 1.3.6.1.4.1.232.1.2.2.1.1.21 type: gauge help: This is the maximum internal speed in megahertz this processor can support - 1.3.6.1.4.1.232.1.2.2.1.1.21 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUCoreThreadIndex oid: 1.3.6.1.4.1.232.1.2.2.1.1.22 type: gauge help: This is an unique number to identify the running threads in a CPU core. - 1.3.6.1.4.1.232.1.2.2.1.1.22 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUChipGenerationName oid: 1.3.6.1.4.1.232.1.2.2.1.1.23 type: DisplayString help: CPU chip generation name e.g - 1.3.6.1.4.1.232.1.2.2.1.1.23 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUMultiThreadStatus oid: 1.3.6.1.4.1.232.1.2.2.1.1.24 type: gauge help: This OID identifies whether the CPU threading is enabled or not. - 1.3.6.1.4.1.232.1.2.2.1.1.24 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: enabled 3: disabled - name: cpqSeCPUCoreMaxThreads oid: 1.3.6.1.4.1.232.1.2.2.1.1.25 type: gauge help: This OID indicates the maximum number of threads that a cpu core is capable of. - 1.3.6.1.4.1.232.1.2.2.1.1.25 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuLowPowerStatus oid: 1.3.6.1.4.1.232.1.2.2.1.1.26 type: gauge help: Servers like Itanium has capability to lower power supply to CPU if it is idle for specified period of time - 1.3.6.1.4.1.232.1.2.2.1.1.26 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: lowpowered 3: normalpowered 4: highpowered - name: cpqSeCpuPrimary oid: 1.3.6.1.4.1.232.1.2.2.1.1.27 type: gauge help: On SMP systems one of the CPU is set to Primary and the other CPUs as secondary - 1.3.6.1.4.1.232.1.2.2.1.1.27 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: "false" 3: "true" - name: cpqSeCpuCoreSteppingText oid: 1.3.6.1.4.1.232.1.2.2.1.1.28 type: DisplayString help: The processor stepping version string - 1.3.6.1.4.1.232.1.2.2.1.1.28 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuCurrentPerformanceState oid: 1.3.6.1.4.1.232.1.2.2.1.1.29 type: gauge help: This OID returns the current performance state of this processor - 1.3.6.1.4.1.232.1.2.2.1.1.29 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuMinPerformanceState oid: 1.3.6.1.4.1.232.1.2.2.1.1.30 type: gauge help: This OID returns the minimum performance state set for this processor - 1.3.6.1.4.1.232.1.2.2.1.1.30 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuMaxPerformanceState oid: 1.3.6.1.4.1.232.1.2.2.1.1.31 type: gauge help: This OID returns the maximum performance state set for this processor - 1.3.6.1.4.1.232.1.2.2.1.1.31 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqHoMibRevMajor oid: 1.3.6.1.4.1.232.11.1.1 type: gauge help: The Major Revision level of the MIB - 1.3.6.1.4.1.232.11.1.1 - name: cpqHoMibRevMinor oid: 1.3.6.1.4.1.232.11.1.2 type: gauge help: The Minor Revision level of the MIB - 1.3.6.1.4.1.232.11.1.2 - name: cpqHoMibCondition oid: 1.3.6.1.4.1.232.11.1.3 type: gauge help: The overall condition - 1.3.6.1.4.1.232.11.1.3 enum_values: 1: unknown 2: ok 3: degraded 4: failed - name: cpqHoOsCommonPollFreq oid: 1.3.6.1.4.1.232.11.2.1.4.1 type: gauge help: The Insight Agent`s polling frequency - 1.3.6.1.4.1.232.11.2.1.4.1 - name: cpqHoOsCommonModuleIndex oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.1 type: gauge help: A unique index for this module description. - 1.3.6.1.4.1.232.11.2.1.4.2.1.1 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoOsCommonModuleName oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.2 type: DisplayString help: The module name. - 1.3.6.1.4.1.232.11.2.1.4.2.1.2 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoOsCommonModuleVersion oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.3 type: DisplayString help: The module version in XX.YY format - 1.3.6.1.4.1.232.11.2.1.4.2.1.3 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoOsCommonModuleDate oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.4 type: OctetString help: The module date - 1.3.6.1.4.1.232.11.2.1.4.2.1.4 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoOsCommonModulePurpose oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.5 type: DisplayString help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.11.2.1.4.2.1.5 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoName oid: 1.3.6.1.4.1.232.11.2.2.1 type: DisplayString help: The name of the host operating system (OS). - 1.3.6.1.4.1.232.11.2.2.1 - name: cpqHoVersion oid: 1.3.6.1.4.1.232.11.2.2.2 type: DisplayString help: The version of the host OS. - 1.3.6.1.4.1.232.11.2.2.2 - name: cpqHoDesc oid: 1.3.6.1.4.1.232.11.2.2.3 type: DisplayString help: A further description of the host OS. - 1.3.6.1.4.1.232.11.2.2.3 - name: cpqHoOsType oid: 1.3.6.1.4.1.232.11.2.2.4 type: gauge help: Host Operating system enumeration. - 1.3.6.1.4.1.232.11.2.2.4 enum_values: 1: other 2: netware 3: windowsnt 4: sco-unix 5: unixware 6: os-2 7: ms-dos 8: dos-windows 9: windows95 10: windows98 11: open-vms 12: nsk 13: windowsCE 14: linux 15: windows2000 16: tru64UNIX 17: windows2003 18: windows2003-x64 19: solaris 20: windows2003-ia64 21: windows2008 22: windows2008-x64 23: windows2008-ia64 24: vmware-esx 25: vmware-esxi 26: windows2012 27: windows7 28: windows7-x64 29: windows8 30: windows8-x64 31: windows81 32: windows81-x64 33: windowsxp 34: windowsxp-x64 35: windowsvista 36: windowsvista-x64 37: windows2008-r2 38: windows2012-r2 39: rhel 40: rhel-64 41: solaris-64 42: sles 43: sles-64 44: ubuntu 45: ubuntu-64 46: debian 47: debian-64 48: linux-64-bit 49: other-64-bit 50: centos-32bit 51: centos-64bit 52: oracle-linux32 53: oracle-linux64 54: apple-osx 55: windows2016 56: nanoserver 57: windows2019 - name: cpqHoTelnet oid: 1.3.6.1.4.1.232.11.2.2.5 type: gauge help: Telnet on socket 23 is available. - 1.3.6.1.4.1.232.11.2.2.5 enum_values: 1: other 2: available 3: notavailable - name: cpqHoSystemRole oid: 1.3.6.1.4.1.232.11.2.2.6 type: DisplayString help: The system role - 1.3.6.1.4.1.232.11.2.2.6 - name: cpqHoSystemRoleDetail oid: 1.3.6.1.4.1.232.11.2.2.7 type: DisplayString help: The system detailed description - 1.3.6.1.4.1.232.11.2.2.7 - name: cpqHoCrashDumpState oid: 1.3.6.1.4.1.232.11.2.2.8 type: gauge help: Crash dump state - 1.3.6.1.4.1.232.11.2.2.8 enum_values: 1: completememorydump 2: kernelmemorydump 3: smallmemorydump 4: none - name: cpqHoCrashDumpCondition oid: 1.3.6.1.4.1.232.11.2.2.9 type: gauge help: The condition of the Crash dump configuration. - 1.3.6.1.4.1.232.11.2.2.9 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHoCrashDumpMonitoring oid: 1.3.6.1.4.1.232.11.2.2.10 type: gauge help: Enable/disable crash dump monitoring - 1.3.6.1.4.1.232.11.2.2.10 enum_values: 1: enabled 2: disabled - name: cpqHoMaxLogicalCPUSupported oid: 1.3.6.1.4.1.232.11.2.2.11 type: gauge help: Maximum number of logical CPUs supported by Operating System. - 1.3.6.1.4.1.232.11.2.2.11 - name: cpqHoSystemName oid: 1.3.6.1.4.1.232.11.2.2.12 type: DisplayString help: Full computer name of the host - 1.3.6.1.4.1.232.11.2.2.12 - name: cpqHosysDescr oid: 1.3.6.1.4.1.232.11.2.2.13 type: DisplayString help: The value that would be returned in the RFC-1213 sysDescr MIB element - 1.3.6.1.4.1.232.11.2.2.13 - name: cpqHoCpuUtilUnitIndex oid: 1.3.6.1.4.1.232.11.2.3.1.1.1 type: gauge help: This number uniquely specifies a processor unit - 1.3.6.1.4.1.232.11.2.3.1.1.1 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilMin oid: 1.3.6.1.4.1.232.11.2.3.1.1.2 type: gauge help: The CPU utilization as a percentage of the theoretical maximum during the last minute - 1.3.6.1.4.1.232.11.2.3.1.1.2 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilFiveMin oid: 1.3.6.1.4.1.232.11.2.3.1.1.3 type: gauge help: The CPU utilization as a percentage of the theoretical maximum during the last five minutes - 1.3.6.1.4.1.232.11.2.3.1.1.3 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilThirtyMin oid: 1.3.6.1.4.1.232.11.2.3.1.1.4 type: gauge help: The CPU utilization as a percentage of the theoretical maximum during the last thirty minutes - 1.3.6.1.4.1.232.11.2.3.1.1.4 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilHour oid: 1.3.6.1.4.1.232.11.2.3.1.1.5 type: gauge help: The CPU utilization as a percentage of the theoretical maximum during the last hour - 1.3.6.1.4.1.232.11.2.3.1.1.5 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilHwLocation oid: 1.3.6.1.4.1.232.11.2.3.1.1.6 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the CPU - 1.3.6.1.4.1.232.11.2.3.1.1.6 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoFileSysIndex oid: 1.3.6.1.4.1.232.11.2.4.1.1.1 type: gauge help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.4.1.1.1 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysDesc oid: 1.3.6.1.4.1.232.11.2.4.1.1.2 type: DisplayString help: A description of the file system include the GUID. - 1.3.6.1.4.1.232.11.2.4.1.1.2 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysSpaceTotal oid: 1.3.6.1.4.1.232.11.2.4.1.1.3 type: gauge help: The file system size in megabytes - 1.3.6.1.4.1.232.11.2.4.1.1.3 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysSpaceUsed oid: 1.3.6.1.4.1.232.11.2.4.1.1.4 type: gauge help: The megabytes of file system space currently in use - 1.3.6.1.4.1.232.11.2.4.1.1.4 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysPercentSpaceUsed oid: 1.3.6.1.4.1.232.11.2.4.1.1.5 type: gauge help: The percent of file system space currently in use - 1.3.6.1.4.1.232.11.2.4.1.1.5 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysAllocUnitsTotal oid: 1.3.6.1.4.1.232.11.2.4.1.1.6 type: gauge help: The total number of files (directory entries) that can be stored on the file system if a limit exists other than total space used - 1.3.6.1.4.1.232.11.2.4.1.1.6 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysAllocUnitsUsed oid: 1.3.6.1.4.1.232.11.2.4.1.1.7 type: gauge help: The number of files (directory entries) on this file system - 1.3.6.1.4.1.232.11.2.4.1.1.7 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysStatus oid: 1.3.6.1.4.1.232.11.2.4.1.1.8 type: gauge help: The Threshold Status - 1.3.6.1.4.1.232.11.2.4.1.1.8 indexes: - labelname: cpqHoFileSysIndex type: gauge enum_values: 1: unknown 2: ok 3: degraded 4: failed - name: cpqHoFileSysShortDesc oid: 1.3.6.1.4.1.232.11.2.4.1.1.9 type: DisplayString help: A description of the file system. - 1.3.6.1.4.1.232.11.2.4.1.1.9 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysCondition oid: 1.3.6.1.4.1.232.11.2.4.2 type: gauge help: The overall condition of File System Threshold - 1.3.6.1.4.1.232.11.2.4.2 enum_values: 1: unknown 2: ok 3: degraded 4: failed - name: cpqHoIfPhysMapIndex oid: 1.3.6.1.4.1.232.11.2.5.1.1.1 type: gauge help: An index that uniquely specifies this entry - 1.3.6.1.4.1.232.11.2.5.1.1.1 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapSlot oid: 1.3.6.1.4.1.232.11.2.5.1.1.2 type: gauge help: The number of the slot containing the physical hardware that implements this interface - 1.3.6.1.4.1.232.11.2.5.1.1.2 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapIoBaseAddr oid: 1.3.6.1.4.1.232.11.2.5.1.1.3 type: gauge help: The base I/O address of the physical hardware that implements this interface. - 1.3.6.1.4.1.232.11.2.5.1.1.3 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapIrq oid: 1.3.6.1.4.1.232.11.2.5.1.1.4 type: gauge help: The number of the IRQ (interrupt) used for this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.4 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapDma oid: 1.3.6.1.4.1.232.11.2.5.1.1.5 type: gauge help: The number of the DMA channel used for this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.5 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapMemBaseAddr oid: 1.3.6.1.4.1.232.11.2.5.1.1.6 type: gauge help: The base memory address used by this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.6 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapPort oid: 1.3.6.1.4.1.232.11.2.5.1.1.7 type: gauge help: The port number of the interface for multi-port NICs - 1.3.6.1.4.1.232.11.2.5.1.1.7 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapDuplexState oid: 1.3.6.1.4.1.232.11.2.5.1.1.8 type: gauge help: This variable describes the configured duplex state of the NIC. - 1.3.6.1.4.1.232.11.2.5.1.1.8 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge enum_values: 1: other 2: half 3: full - name: cpqHoIfPhysMapCondition oid: 1.3.6.1.4.1.232.11.2.5.1.1.9 type: gauge help: The condition of this interface. - 1.3.6.1.4.1.232.11.2.5.1.1.9 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHoIfPhysMapOverallCondition oid: 1.3.6.1.4.1.232.11.2.5.2 type: gauge help: The overall condition of all interfaces. - 1.3.6.1.4.1.232.11.2.5.2 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHoSWRunningIndex oid: 1.3.6.1.4.1.232.11.2.6.1.1.1 type: gauge help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.6.1.1.1 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningName oid: 1.3.6.1.4.1.232.11.2.6.1.1.2 type: DisplayString help: The name of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.2 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningDesc oid: 1.3.6.1.4.1.232.11.2.6.1.1.3 type: DisplayString help: A description of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.3 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningVersion oid: 1.3.6.1.4.1.232.11.2.6.1.1.4 type: DisplayString help: The version of the software - 1.3.6.1.4.1.232.11.2.6.1.1.4 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningDate oid: 1.3.6.1.4.1.232.11.2.6.1.1.5 type: OctetString help: The software date - 1.3.6.1.4.1.232.11.2.6.1.1.5 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningMonitor oid: 1.3.6.1.4.1.232.11.2.6.1.1.6 type: gauge help: The user specified monitor option for a process. - 1.3.6.1.4.1.232.11.2.6.1.1.6 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: other 2: start 3: stop 4: startAndStop 5: count 6: startAndCount 7: countAndStop 8: startCountAndStop - name: cpqHoSWRunningState oid: 1.3.6.1.4.1.232.11.2.6.1.1.7 type: gauge help: The current state of monitored process. - 1.3.6.1.4.1.232.11.2.6.1.1.7 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: other 2: started 3: stopped - name: cpqHoSWRunningCount oid: 1.3.6.1.4.1.232.11.2.6.1.1.8 type: gauge help: For each process name, the number of instances of the process running on the system is kept count of, in this variable. - 1.3.6.1.4.1.232.11.2.6.1.1.8 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningCountMin oid: 1.3.6.1.4.1.232.11.2.6.1.1.9 type: gauge help: This is the lower threshold on cpqHoSWRunningCount to be set by the user. - 1.3.6.1.4.1.232.11.2.6.1.1.9 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningCountMax oid: 1.3.6.1.4.1.232.11.2.6.1.1.10 type: gauge help: This is the upper threshold on cpqHoSWRunningCount to be set by the user. - 1.3.6.1.4.1.232.11.2.6.1.1.10 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningEventTime oid: 1.3.6.1.4.1.232.11.2.6.1.1.11 type: OctetString help: The system time at which the monitored event, as per cpqHoSWRunningMonitor, last occurred - 1.3.6.1.4.1.232.11.2.6.1.1.11 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningStatus oid: 1.3.6.1.4.1.232.11.2.6.1.1.12 type: gauge help: The overall alarm state of the resources managed by the software, or the software itself. - 1.3.6.1.4.1.232.11.2.6.1.1.12 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: unknown 2: normal 3: warning 4: minor 5: major 6: critical 7: disabled - name: cpqHoSWRunningConfigStatus oid: 1.3.6.1.4.1.232.11.2.6.1.1.13 type: gauge help: The configuration state of the software - 1.3.6.1.4.1.232.11.2.6.1.1.13 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: unknown 2: starting 3: initialized 4: configured 5: operational - name: cpqHoSWRunningIdentifier oid: 1.3.6.1.4.1.232.11.2.6.1.1.14 type: DisplayString help: The unique identifier of the sofware - 1.3.6.1.4.1.232.11.2.6.1.1.14 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningRedundancyMode oid: 1.3.6.1.4.1.232.11.2.6.1.1.15 type: gauge help: When the software is running in a high availability mode, the failover mode of this instance of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.15 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: unknown 2: master 3: backup 4: slave - name: cpqHoSwRunningTrapDesc oid: 1.3.6.1.4.1.232.11.2.6.2 type: DisplayString help: The error message for a process monitor event. - 1.3.6.1.4.1.232.11.2.6.2 - name: cpqHoSwVerNextIndex oid: 1.3.6.1.4.1.232.11.2.7.1 type: gauge help: The index of the next available entry in the cpqHoSwVer table - 1.3.6.1.4.1.232.11.2.7.1 - name: cpqHoSwVerIndex oid: 1.3.6.1.4.1.232.11.2.7.2.1.1 type: gauge help: An index that uniquely identifies an entry in the cpqHoSwVer table. - 1.3.6.1.4.1.232.11.2.7.2.1.1 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerStatus oid: 1.3.6.1.4.1.232.11.2.7.2.1.2 type: gauge help: Status for the software item. - 1.3.6.1.4.1.232.11.2.7.2.1.2 indexes: - labelname: cpqHoSwVerIndex type: gauge enum_values: 1: other 2: loaded 3: notloaded - name: cpqHoSwVerType oid: 1.3.6.1.4.1.232.11.2.7.2.1.3 type: gauge help: Type of software item. - 1.3.6.1.4.1.232.11.2.7.2.1.3 indexes: - labelname: cpqHoSwVerIndex type: gauge enum_values: 1: other 2: driver 3: agent 4: sysutil 5: application 6: keyfile 7: firmware - name: cpqHoSwVerName oid: 1.3.6.1.4.1.232.11.2.7.2.1.4 type: DisplayString help: The name of this software item. - 1.3.6.1.4.1.232.11.2.7.2.1.4 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerDescription oid: 1.3.6.1.4.1.232.11.2.7.2.1.5 type: DisplayString help: The description of this software item. - 1.3.6.1.4.1.232.11.2.7.2.1.5 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerDate oid: 1.3.6.1.4.1.232.11.2.7.2.1.6 type: OctetString help: The date of the software item, if any - 1.3.6.1.4.1.232.11.2.7.2.1.6 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerLocation oid: 1.3.6.1.4.1.232.11.2.7.2.1.7 type: DisplayString help: The location of this software item on the server. - 1.3.6.1.4.1.232.11.2.7.2.1.7 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerVersion oid: 1.3.6.1.4.1.232.11.2.7.2.1.8 type: DisplayString help: An string that specifies the version of this item. - 1.3.6.1.4.1.232.11.2.7.2.1.8 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerVersionBinary oid: 1.3.6.1.4.1.232.11.2.7.2.1.9 type: DisplayString help: An string that specifies the version of this item based on the binary version resource. - 1.3.6.1.4.1.232.11.2.7.2.1.9 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerAgentsVer oid: 1.3.6.1.4.1.232.11.2.7.3 type: DisplayString help: A string that specifies the version of the Insight Management Agents running on the system. - 1.3.6.1.4.1.232.11.2.7.3 - name: cpqHoGenericData oid: 1.3.6.1.4.1.232.11.2.8.1 type: DisplayString help: Data for the generic trap. - 1.3.6.1.4.1.232.11.2.8.1 - name: cpqHoCriticalSoftwareUpdateData oid: 1.3.6.1.4.1.232.11.2.8.2 type: DisplayString help: Data for the Critical Software Update trap. - 1.3.6.1.4.1.232.11.2.8.2 - name: cpqHoSwPerfAppErrorDesc oid: 1.3.6.1.4.1.232.11.2.9.1 type: DisplayString help: This string holds error information about the last application error that occurred in the system. - 1.3.6.1.4.1.232.11.2.9.1 - name: cpqHoMibStatusArray oid: 1.3.6.1.4.1.232.11.2.10.1 type: OctetString help: The MIB Status Array is an array of MIB status structures - 1.3.6.1.4.1.232.11.2.10.1 - name: cpqHoConfigChangedDate oid: 1.3.6.1.4.1.232.11.2.10.2 type: OctetString help: The date/time when the agents were last loaded - 1.3.6.1.4.1.232.11.2.10.2 - name: cpqHoGUID oid: 1.3.6.1.4.1.232.11.2.10.3 type: OctetString help: The globally unique identifier of this physical server - 1.3.6.1.4.1.232.11.2.10.3 - name: cpqHoCodeServer oid: 1.3.6.1.4.1.232.11.2.10.4 type: gauge help: This item indicates how many code server shares are currently configured on the system - 1.3.6.1.4.1.232.11.2.10.4 - name: cpqHoWebMgmtPort oid: 1.3.6.1.4.1.232.11.2.10.5 type: gauge help: This item indicates the port used by the Insight Web Agent - 1.3.6.1.4.1.232.11.2.10.5 - name: cpqHoGUIDCanonical oid: 1.3.6.1.4.1.232.11.2.10.6 type: OctetString help: The globally unique identifier in canonical format of this physical server - 1.3.6.1.4.1.232.11.2.10.6 - name: cpqHoMibHealthStatusArray oid: 1.3.6.1.4.1.232.11.2.10.7 type: OctetString help: 'The MIB Health Status Array is an array of status values representing an overall status in element 0 follwed by server and storage status values as follows: Octet Element Field ======== ======= ========= 0 0 Aggregated Status of array elements 1 1 Status of element 1 2 2 Status of element 2 - 1.3.6.1.4.1.232.11.2.10.7' - name: cpqHoTrapFlags oid: 1.3.6.1.4.1.232.11.2.11.1 type: gauge help: The Trap Flags - 1.3.6.1.4.1.232.11.2.11.1 - name: cpqHoClientLastModified oid: 1.3.6.1.4.1.232.11.2.12.1 type: OctetString help: The date/time of the last modification to the client table - 1.3.6.1.4.1.232.11.2.12.1 - name: cpqHoClientDelete oid: 1.3.6.1.4.1.232.11.2.12.2 type: DisplayString help: Setting this variable to the name of a client in the client table will cause that row in the table to be deleted - 1.3.6.1.4.1.232.11.2.12.2 - name: cpqHoClientIndex oid: 1.3.6.1.4.1.232.11.2.12.3.1.1 type: gauge help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.12.3.1.1 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientName oid: 1.3.6.1.4.1.232.11.2.12.3.1.2 type: DisplayString help: The Win95 machine name of this client. - 1.3.6.1.4.1.232.11.2.12.3.1.2 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientIpxAddress oid: 1.3.6.1.4.1.232.11.2.12.3.1.3 type: OctetString help: The IPX address for this client, all octets should be set to 0xff if this machine does not support IPX - 1.3.6.1.4.1.232.11.2.12.3.1.3 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientIpAddress oid: 1.3.6.1.4.1.232.11.2.12.3.1.4 type: InetAddressIPv4 help: The IP address for this client, all octets should be set to 0xff if this machine does not support IP - 1.3.6.1.4.1.232.11.2.12.3.1.4 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientCommunity oid: 1.3.6.1.4.1.232.11.2.12.3.1.5 type: DisplayString help: A community name that can be used to query the client with SNMP - 1.3.6.1.4.1.232.11.2.12.3.1.5 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientID oid: 1.3.6.1.4.1.232.11.2.12.3.1.6 type: OctetString help: The unique identifier of this client. - 1.3.6.1.4.1.232.11.2.12.3.1.6 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoPhysicalMemorySize oid: 1.3.6.1.4.1.232.11.2.13.1 type: gauge help: Total amount of physical memory as seen by the OS (in megabytes) - 1.3.6.1.4.1.232.11.2.13.1 - name: cpqHoPhysicalMemoryFree oid: 1.3.6.1.4.1.232.11.2.13.2 type: gauge help: The amount of free physical memory (in megabytes) - 1.3.6.1.4.1.232.11.2.13.2 - name: cpqHoPagingMemorySize oid: 1.3.6.1.4.1.232.11.2.13.3 type: gauge help: Total virtual memory available from the OS (in megabytes) - 1.3.6.1.4.1.232.11.2.13.3 - name: cpqHoPagingMemoryFree oid: 1.3.6.1.4.1.232.11.2.13.4 type: gauge help: Available paging memory (in megabytes) - 1.3.6.1.4.1.232.11.2.13.4 - name: cpqHoBootPagingFileSize oid: 1.3.6.1.4.1.232.11.2.13.5 type: DisplayString help: The paging file size of the boot volume in the format xxxMB or xxxGB, where xxx is the paging file size in that unit shown right after it - 1.3.6.1.4.1.232.11.2.13.5 - name: cpqHoBootPagingFileMinimumSize oid: 1.3.6.1.4.1.232.11.2.13.6 type: DisplayString help: Minimum paging file size of the boot volume required to save the memory dump in the event of a system crash - 1.3.6.1.4.1.232.11.2.13.6 - name: cpqHoBootPagingFileVolumeFreeSpace oid: 1.3.6.1.4.1.232.11.2.13.7 type: DisplayString help: Free space of the boot volume required to save the memory dump in the event of a system crash - 1.3.6.1.4.1.232.11.2.13.7 - name: cpqHoFwVerIndex oid: 1.3.6.1.4.1.232.11.2.14.1.1.1 type: gauge help: Firmware Version Index - 1.3.6.1.4.1.232.11.2.14.1.1.1 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerCategory oid: 1.3.6.1.4.1.232.11.2.14.1.1.2 type: gauge help: Firmware Version Category. - 1.3.6.1.4.1.232.11.2.14.1.1.2 indexes: - labelname: cpqHoFwVerIndex type: gauge enum_values: 1: other 2: storage 3: nic 4: rib 5: system - name: cpqHoFwVerDeviceType oid: 1.3.6.1.4.1.232.11.2.14.1.1.3 type: gauge help: Firmware Version Device Type. - 1.3.6.1.4.1.232.11.2.14.1.1.3 indexes: - labelname: cpqHoFwVerIndex type: gauge enum_values: 1: other 2: internalArrayController 3: fibreArrayController 4: scsiController 5: fibreChannelTapeController 6: modularDataRouter 7: ideCdRomDrive 8: ideDiskDrive 9: scsiCdRom-ScsiAttached 10: scsiDiskDrive-ScsiAttached 11: scsiTapeDrive-ScsiAttached 12: scsiTapeLibrary-ScsiAttached 13: scsiDiskDrive-ArrayAttached 14: scsiTapeDrive-ArrayAttached 15: scsiTapeLibrary-ArrayAttached 16: scsiDiskDrive-FibreAttached 17: scsiTapeDrive-FibreAttached 18: scsiTapeLibrary-FibreAttached 19: scsiEnclosureBackplaneRom-ScsiAttached 20: scsiEnclosureBackplaneRom-ArrayAttached 21: scsiEnclosureBackplaneRom-FibreAttached 22: scsiEnclosureBackplaneRom-ra4x00 23: systemRom 24: networkInterfaceController 25: remoteInsightBoard 26: sasDiskDrive-SasAttached 27: sataDiskDrive-SataAttached 28: usbController 29: sasControllerAdapter 30: sataControllerAdapter 31: systemDevice 32: fibreChannelHba 33: convergedNetworkAdapter 34: ideController - name: cpqHoFwVerDisplayName oid: 1.3.6.1.4.1.232.11.2.14.1.1.4 type: DisplayString help: Firmware Version Device Display Name - 1.3.6.1.4.1.232.11.2.14.1.1.4 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerVersion oid: 1.3.6.1.4.1.232.11.2.14.1.1.5 type: DisplayString help: Firmware Version - 1.3.6.1.4.1.232.11.2.14.1.1.5 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerLocation oid: 1.3.6.1.4.1.232.11.2.14.1.1.6 type: DisplayString help: Firmware Version Device Location - 1.3.6.1.4.1.232.11.2.14.1.1.6 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerXmlString oid: 1.3.6.1.4.1.232.11.2.14.1.1.7 type: DisplayString help: Firmware Version Xml String - 1.3.6.1.4.1.232.11.2.14.1.1.7 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerKeyString oid: 1.3.6.1.4.1.232.11.2.14.1.1.8 type: DisplayString help: Firmware Version Key String - 1.3.6.1.4.1.232.11.2.14.1.1.8 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerUpdateMethod oid: 1.3.6.1.4.1.232.11.2.14.1.1.9 type: gauge help: Firmware Version update method. - 1.3.6.1.4.1.232.11.2.14.1.1.9 indexes: - labelname: cpqHoFwVerIndex type: gauge enum_values: 1: other 2: noUpdate 3: softwareflash 4: replacePhysicalRom - name: cpqHoHWInfoPlatform oid: 1.3.6.1.4.1.232.11.2.15.1 type: gauge help: Hardware platform type - 1.3.6.1.4.1.232.11.2.15.1 enum_values: 1: unknown 2: cellular 3: foundation 4: virtualMachine 5: serverBlade - name: cpqPwrWarnType oid: 1.3.6.1.4.1.232.11.2.16.1 type: DisplayString help: Type of power reading on which the warning is based. - 1.3.6.1.4.1.232.11.2.16.1 - name: cpqPwrWarnThreshold oid: 1.3.6.1.4.1.232.11.2.16.2 type: gauge help: The threshold the power usage must exceed (in Watts). - 1.3.6.1.4.1.232.11.2.16.2 - name: cpqPwrWarnDuration oid: 1.3.6.1.4.1.232.11.2.16.3 type: gauge help: Duration that power usage must be exceeded before warning (in minutes). - 1.3.6.1.4.1.232.11.2.16.3 - name: cpqSerialNum oid: 1.3.6.1.4.1.232.11.2.16.4 type: DisplayString help: Serial number of the server. - 1.3.6.1.4.1.232.11.2.16.4 - name: cpqServerUUID oid: 1.3.6.1.4.1.232.11.2.16.5 type: DisplayString help: Server UUID - 1.3.6.1.4.1.232.11.2.16.5 - name: cpqIdeMibRevMajor oid: 1.3.6.1.4.1.232.14.1.1 type: gauge help: The Major Revision level - 1.3.6.1.4.1.232.14.1.1 - name: cpqIdeMibRevMinor oid: 1.3.6.1.4.1.232.14.1.2 type: gauge help: The Minor Revision level - 1.3.6.1.4.1.232.14.1.2 - name: cpqIdeMibCondition oid: 1.3.6.1.4.1.232.14.1.3 type: gauge help: The overall condition - 1.3.6.1.4.1.232.14.1.3 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeOsCommonPollFreq oid: 1.3.6.1.4.1.232.14.2.1.4.1 type: gauge help: The Insight Agent`s polling frequency - 1.3.6.1.4.1.232.14.2.1.4.1 - name: cpqIdeOsCommonModuleIndex oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.1 type: gauge help: A unique index for this module description. - 1.3.6.1.4.1.232.14.2.1.4.2.1.1 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeOsCommonModuleName oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.2 type: DisplayString help: The module name. - 1.3.6.1.4.1.232.14.2.1.4.2.1.2 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeOsCommonModuleVersion oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.3 type: DisplayString help: The module version in XX.YY format - 1.3.6.1.4.1.232.14.2.1.4.2.1.3 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeOsCommonModuleDate oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.4 type: OctetString help: The module date - 1.3.6.1.4.1.232.14.2.1.4.2.1.4 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeOsCommonModulePurpose oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.5 type: DisplayString help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.14.2.1.4.2.1.5 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeIdentIndex oid: 1.3.6.1.4.1.232.14.2.2.1.1.1 type: gauge help: An index that uniquely specifies each device - 1.3.6.1.4.1.232.14.2.2.1.1.1 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentModel oid: 1.3.6.1.4.1.232.14.2.2.1.1.2 type: DisplayString help: IDE Drive Model - 1.3.6.1.4.1.232.14.2.2.1.1.2 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentSerNum oid: 1.3.6.1.4.1.232.14.2.2.1.1.3 type: DisplayString help: IDE Drive Serial Number - 1.3.6.1.4.1.232.14.2.2.1.1.3 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentFWVers oid: 1.3.6.1.4.1.232.14.2.2.1.1.4 type: DisplayString help: IDE Firmware Version - 1.3.6.1.4.1.232.14.2.2.1.1.4 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentCondition oid: 1.3.6.1.4.1.232.14.2.2.1.1.5 type: gauge help: IDE Drive Condition - 1.3.6.1.4.1.232.14.2.2.1.1.5 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeIdentErrorNumber oid: 1.3.6.1.4.1.232.14.2.2.1.1.6 type: DisplayString help: IDE Error Number - 1.3.6.1.4.1.232.14.2.2.1.1.6 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentType oid: 1.3.6.1.4.1.232.14.2.2.1.1.7 type: gauge help: IDE Device Type - 1.3.6.1.4.1.232.14.2.2.1.1.7 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: disk 3: tape 4: printer 5: processor 6: wormDrive 7: cd-rom 8: scanner 9: optical 10: jukeBox 11: commDev - name: cpqIdeIdentTypeExtended oid: 1.3.6.1.4.1.232.14.2.2.1.1.8 type: gauge help: IDE Extended Device Type - 1.3.6.1.4.1.232.14.2.2.1.1.8 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: pdcd 3: removableDisk - name: cpqIdeIdentCondition2 oid: 1.3.6.1.4.1.232.14.2.2.1.1.9 type: gauge help: IDE Drive Condition - 1.3.6.1.4.1.232.14.2.2.1.1.9 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeIdentStatus oid: 1.3.6.1.4.1.232.14.2.2.1.1.10 type: gauge help: IDE Drive Satus - 1.3.6.1.4.1.232.14.2.2.1.1.10 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: ok 3: preFailureDegraded 4: ultraAtaDegraded - name: cpqIdeIdentUltraAtaAvailability oid: 1.3.6.1.4.1.232.14.2.2.1.1.11 type: gauge help: This describes the availability of Ultra ATA transfers between this device and the controller - 1.3.6.1.4.1.232.14.2.2.1.1.11 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: noNotSupportedByDeviceAndController 3: noNotSupportedByDevice 4: noNotSupportedByController 5: noDisabledInSetup 6: yesEnabledInSetup - name: cpqIdeControllerIndex oid: 1.3.6.1.4.1.232.14.2.3.1.1.1 type: gauge help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.3.1.1.1 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerOverallCondition oid: 1.3.6.1.4.1.232.14.2.3.1.1.2 type: gauge help: IDE Controller Overall Condition - 1.3.6.1.4.1.232.14.2.3.1.1.2 indexes: - labelname: cpqIdeControllerIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeControllerModel oid: 1.3.6.1.4.1.232.14.2.3.1.1.3 type: DisplayString help: IDE Controller Model - 1.3.6.1.4.1.232.14.2.3.1.1.3 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerFwRev oid: 1.3.6.1.4.1.232.14.2.3.1.1.4 type: DisplayString help: IDE Controller Firmware Revision - 1.3.6.1.4.1.232.14.2.3.1.1.4 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerSlot oid: 1.3.6.1.4.1.232.14.2.3.1.1.5 type: gauge help: IDE Controller Slot - 1.3.6.1.4.1.232.14.2.3.1.1.5 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerStatus oid: 1.3.6.1.4.1.232.14.2.3.1.1.6 type: gauge help: IDE Channel Host Controller Status - 1.3.6.1.4.1.232.14.2.3.1.1.6 indexes: - labelname: cpqIdeControllerIndex type: gauge enum_values: 1: other 2: ok 3: failed - name: cpqIdeControllerCondition oid: 1.3.6.1.4.1.232.14.2.3.1.1.7 type: gauge help: IDE Controller Condition - 1.3.6.1.4.1.232.14.2.3.1.1.7 indexes: - labelname: cpqIdeControllerIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeControllerSerialNumber oid: 1.3.6.1.4.1.232.14.2.3.1.1.8 type: DisplayString help: IDE Controller Serial Number - 1.3.6.1.4.1.232.14.2.3.1.1.8 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerHwLocation oid: 1.3.6.1.4.1.232.14.2.3.1.1.9 type: DisplayString help: IDE Controller Hardware Location - 1.3.6.1.4.1.232.14.2.3.1.1.9 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerPciLocation oid: 1.3.6.1.4.1.232.14.2.3.1.1.10 type: DisplayString help: IDE Controller PCI Location - 1.3.6.1.4.1.232.14.2.3.1.1.10 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeAtaDiskControllerIndex oid: 1.3.6.1.4.1.232.14.2.4.1.1.1 type: gauge help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.4.1.1.1 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskIndex oid: 1.3.6.1.4.1.232.14.2.4.1.1.2 type: gauge help: An index that uniquely identifies each disk. - 1.3.6.1.4.1.232.14.2.4.1.1.2 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskModel oid: 1.3.6.1.4.1.232.14.2.4.1.1.3 type: DisplayString help: ATA Disk Model - 1.3.6.1.4.1.232.14.2.4.1.1.3 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskFwRev oid: 1.3.6.1.4.1.232.14.2.4.1.1.4 type: DisplayString help: ATA Disk Firmware Revision - 1.3.6.1.4.1.232.14.2.4.1.1.4 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskSerialNumber oid: 1.3.6.1.4.1.232.14.2.4.1.1.5 type: DisplayString help: ATA Disk Serial Number - 1.3.6.1.4.1.232.14.2.4.1.1.5 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskStatus oid: 1.3.6.1.4.1.232.14.2.4.1.1.6 type: gauge help: ATA Disk Status - 1.3.6.1.4.1.232.14.2.4.1.1.6 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: ok 3: smartError 4: failed 5: ssdWearOut - name: cpqIdeAtaDiskCondition oid: 1.3.6.1.4.1.232.14.2.4.1.1.7 type: gauge help: ATA Disk Condition - 1.3.6.1.4.1.232.14.2.4.1.1.7 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeAtaDiskCapacity oid: 1.3.6.1.4.1.232.14.2.4.1.1.8 type: gauge help: ATA Disk Capacity - 1.3.6.1.4.1.232.14.2.4.1.1.8 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskSmartEnabled oid: 1.3.6.1.4.1.232.14.2.4.1.1.9 type: gauge help: ATA Disk S.M.A.R.T Enabled? other(1) The agent cannot determine the state of S.M.A.R.T - 1.3.6.1.4.1.232.14.2.4.1.1.9 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqIdeAtaDiskTransferMode oid: 1.3.6.1.4.1.232.14.2.4.1.1.10 type: gauge help: ATA Disk Transfer Mode - 1.3.6.1.4.1.232.14.2.4.1.1.10 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: pioMode0 3: pioMode1 4: pioMode2 5: pioMode3 6: pioMode4 7: dmaMode0 8: dmaMode1 9: dmaMode2 10: ultraDmaMode0 11: ultraDmaMode1 12: ultraDmaMode2 13: ultraDmaMode3 14: ultraDmaMode4 15: ultraDmaMode5 - name: cpqIdeAtaDiskChannel oid: 1.3.6.1.4.1.232.14.2.4.1.1.11 type: gauge help: ATA Disk Channel - 1.3.6.1.4.1.232.14.2.4.1.1.11 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: channel0 3: channel1 4: serial - name: cpqIdeAtaDiskNumber oid: 1.3.6.1.4.1.232.14.2.4.1.1.12 type: gauge help: ATA Disk Number - 1.3.6.1.4.1.232.14.2.4.1.1.12 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: device0 3: device1 4: sataDevice0 5: sataDevice1 6: sataDevice2 7: sataDevice3 8: sataDevice4 9: sataDevice5 10: sataDevice6 11: sataDevice7 21: bay1 22: bay2 23: bay3 24: bay4 25: bay5 26: bay6 27: bay7 28: bay8 29: bay9 30: bay10 31: bay11 32: bay12 33: bay13 34: bay14 - name: cpqIdeAtaDiskLogicalDriveMember oid: 1.3.6.1.4.1.232.14.2.4.1.1.13 type: gauge help: Logical Drive Membership? other(1) The agent cannot determine if the ATA disk is part of a logical drive - 1.3.6.1.4.1.232.14.2.4.1.1.13 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqIdeAtaDiskIsSpare oid: 1.3.6.1.4.1.232.14.2.4.1.1.14 type: gauge help: ATA Disk Spare? other(1) The agent cannot determine if the ATA disk is a spare - 1.3.6.1.4.1.232.14.2.4.1.1.14 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqIdeAtaDiskOsName oid: 1.3.6.1.4.1.232.14.2.4.1.1.15 type: DisplayString help: ATA Disk OS Name - 1.3.6.1.4.1.232.14.2.4.1.1.15 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskType oid: 1.3.6.1.4.1.232.14.2.4.1.1.16 type: gauge help: ATA Disk Type other(1) The agent cannot determine the disk type - 1.3.6.1.4.1.232.14.2.4.1.1.16 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: ata 3: sata - name: cpqIdeAtaDiskSataVersion oid: 1.3.6.1.4.1.232.14.2.4.1.1.17 type: gauge help: Physical Drive SATA Version - 1.3.6.1.4.1.232.14.2.4.1.1.17 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: sataOne 3: sataTwo - name: cpqIdeAtaDiskMediaType oid: 1.3.6.1.4.1.232.14.2.4.1.1.18 type: gauge help: SATA Physical Drive Media Type - 1.3.6.1.4.1.232.14.2.4.1.1.18 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: rotatingPlatters 3: solidState - name: cpqIdeAtaDiskSSDWearStatus oid: 1.3.6.1.4.1.232.14.2.4.1.1.19 type: gauge help: SATA Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.14.2.4.1.1.19 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: ok 3: fiftySixDayThreshold 4: fivePercentThreshold 5: twoPercentThreshold 6: ssdWearOut - name: cpqIdeAtaDiskPowerOnHours oid: 1.3.6.1.4.1.232.14.2.4.1.1.20 type: counter help: SATA Physical Drive Power On Hours - 1.3.6.1.4.1.232.14.2.4.1.1.20 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskSSDPercntEndrnceUsed oid: 1.3.6.1.4.1.232.14.2.4.1.1.21 type: gauge help: SATA Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.14.2.4.1.1.21 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskSSDEstTimeRemainingHours oid: 1.3.6.1.4.1.232.14.2.4.1.1.22 type: counter help: SATA Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.14.2.4.1.1.22 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskCurrTemperature oid: 1.3.6.1.4.1.232.14.2.4.1.1.23 type: gauge help: SATA Physical Drive Current Operating Temperature degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.23 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskTemperatureThreshold oid: 1.3.6.1.4.1.232.14.2.4.1.1.24 type: gauge help: SATA Physical Drive Maximum Operating Temperature in degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.24 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskMaximumOperatingTemp oid: 1.3.6.1.4.1.232.14.2.4.1.1.25 type: gauge help: SATA Physical Drive Maximum Operating Temperature, as specified by the manufacturer, in degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.25 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskDestructiveOperatingTemp oid: 1.3.6.1.4.1.232.14.2.4.1.1.26 type: gauge help: SATA Physical Drive Destructive Operating Temperature, as specified by the manufacturer, in degrees Celsius, which if exceeded can cause damage to the drive - 1.3.6.1.4.1.232.14.2.4.1.1.26 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaEraseFailureType oid: 1.3.6.1.4.1.232.14.2.4.2 type: gauge help: The value specifies the secure erase status of SATA drive - 1.3.6.1.4.1.232.14.2.4.2 enum_values: 1: secureEraseFailed 2: secureEraseNotSupported 3: noEraseSupported - name: cpqIdeAtapiDeviceControllerIndex oid: 1.3.6.1.4.1.232.14.2.5.1.1.1 type: gauge help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.5.1.1.1 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge - name: cpqIdeAtapiDeviceIndex oid: 1.3.6.1.4.1.232.14.2.5.1.1.2 type: gauge help: An index that uniquely identifies each ATAPI device. - 1.3.6.1.4.1.232.14.2.5.1.1.2 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge - name: cpqIdeAtapiDeviceModel oid: 1.3.6.1.4.1.232.14.2.5.1.1.3 type: DisplayString help: ATAPI Device Model - 1.3.6.1.4.1.232.14.2.5.1.1.3 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge - name: cpqIdeAtapiDeviceFwRev oid: 1.3.6.1.4.1.232.14.2.5.1.1.4 type: DisplayString help: ATAPI Device Firmware Revision - 1.3.6.1.4.1.232.14.2.5.1.1.4 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge - name: cpqIdeAtapiDeviceType oid: 1.3.6.1.4.1.232.14.2.5.1.1.5 type: gauge help: ATAPI Device Type - 1.3.6.1.4.1.232.14.2.5.1.1.5 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge enum_values: 1: other 2: disk 3: tape 4: printer 5: processor 6: wormDrive 7: cd-rom 8: scanner 9: optical 10: jukeBox 11: commDev - name: cpqIdeAtapiDeviceTypeExtended oid: 1.3.6.1.4.1.232.14.2.5.1.1.6 type: gauge help: ATAPI Extended Device Type - 1.3.6.1.4.1.232.14.2.5.1.1.6 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge enum_values: 1: other 2: pdcd 3: removableDisk - name: cpqIdeAtapiDeviceChannel oid: 1.3.6.1.4.1.232.14.2.5.1.1.7 type: gauge help: ATAPI Device Channel - 1.3.6.1.4.1.232.14.2.5.1.1.7 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge enum_values: 1: other 2: channel0 3: channel1 - name: cpqIdeAtapiDeviceNumber oid: 1.3.6.1.4.1.232.14.2.5.1.1.8 type: gauge help: ATAPI Device Number - 1.3.6.1.4.1.232.14.2.5.1.1.8 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge enum_values: 1: other 2: device0 3: device1 - name: cpqIdeLogicalDriveControllerIndex oid: 1.3.6.1.4.1.232.14.2.6.1.1.1 type: gauge help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.6.1.1.1 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveIndex oid: 1.3.6.1.4.1.232.14.2.6.1.1.2 type: gauge help: An index that uniquely identifies each logical drive. - 1.3.6.1.4.1.232.14.2.6.1.1.2 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveRaidLevel oid: 1.3.6.1.4.1.232.14.2.6.1.1.3 type: gauge help: IDE Logical Drive RAID Level - 1.3.6.1.4.1.232.14.2.6.1.1.3 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge enum_values: 1: other 2: raid0 3: raid1 4: raid0plus1 5: raid5 6: raid15 7: volume - name: cpqIdeLogicalDriveCapacity oid: 1.3.6.1.4.1.232.14.2.6.1.1.4 type: gauge help: IDE Logical Drive Capacity - 1.3.6.1.4.1.232.14.2.6.1.1.4 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveStatus oid: 1.3.6.1.4.1.232.14.2.6.1.1.5 type: gauge help: IDE Logical Drive Status - 1.3.6.1.4.1.232.14.2.6.1.1.5 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: rebuilding 5: failed - name: cpqIdeLogicalDriveCondition oid: 1.3.6.1.4.1.232.14.2.6.1.1.6 type: gauge help: IDE Logical Drive Condition - 1.3.6.1.4.1.232.14.2.6.1.1.6 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeLogicalDriveDiskIds oid: 1.3.6.1.4.1.232.14.2.6.1.1.7 type: OctetString help: IDE Logical Drive Disk ID list - 1.3.6.1.4.1.232.14.2.6.1.1.7 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveStripeSize oid: 1.3.6.1.4.1.232.14.2.6.1.1.8 type: gauge help: IDE Logical Drive Stripe Size - 1.3.6.1.4.1.232.14.2.6.1.1.8 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveSpareIds oid: 1.3.6.1.4.1.232.14.2.6.1.1.9 type: OctetString help: IDE Logical Drive Spare ID list - 1.3.6.1.4.1.232.14.2.6.1.1.9 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveRebuildingDisk oid: 1.3.6.1.4.1.232.14.2.6.1.1.10 type: gauge help: IDE Logical Drive Rebuilding Disk - 1.3.6.1.4.1.232.14.2.6.1.1.10 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveOsName oid: 1.3.6.1.4.1.232.14.2.6.1.1.11 type: DisplayString help: IDE Logical Drive OS Name - 1.3.6.1.4.1.232.14.2.6.1.1.11 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqDaCntlrIndex oid: 1.3.6.1.4.1.232.3.2.2.1.1.1 type: gauge help: Array Controller Index - 1.3.6.1.4.1.232.3.2.2.1.1.1 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrModel oid: 1.3.6.1.4.1.232.3.2.2.1.1.2 type: gauge help: Array Controller Model - 1.3.6.1.4.1.232.3.2.2.1.1.2 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ida 3: idaExpansion 4: ida-2 5: smart 6: smart-2e 7: smart-2p 8: smart-2sl 9: smart-3100es 10: smart-3200 11: smart-2dh 12: smart-221 13: sa-4250es 14: sa-4200 15: sa-integrated 16: sa-431 17: sa-5300 18: raidLc2 19: sa-5i 20: sa-532 21: sa-5312 22: sa-641 23: sa-642 24: sa-6400 25: sa-6400em 26: sa-6i 27: sa-generic 29: sa-p600 30: sa-p400 31: sa-e200 32: sa-e200i 33: sa-p400i 34: sa-p800 35: sa-e500 36: sa-p700m 37: sa-p212 38: sa-p410 39: sa-p410i 40: sa-p411 41: sa-b110i 42: sa-p712m 43: sa-p711m 44: sa-p812 45: sw-1210m 46: sa-p220i 47: sa-p222 48: sa-p420 49: sa-p420i 50: sa-p421 51: sa-b320i 52: sa-p822 53: sa-p721m 54: sa-b120i 55: hps-1224 56: hps-1228 57: hps-1228m 58: sa-p822se 59: hps-1224e 60: hps-1228e 61: hps-1228em 62: sa-p230i 63: sa-p430i 64: sa-p430 65: sa-p431 66: sa-p731m 67: sa-p830i 68: sa-p830 69: sa-p831 70: sa-p530 71: sa-p531 72: sa-p244br 73: sa-p246br 74: sa-p440 75: sa-p440ar 76: sa-p441 77: sa-p741m 78: sa-p840 79: sa-p841 80: sh-h240ar 81: sh-h244br 82: sh-h240 83: sh-h241 84: sa-b140i 85: sh-generic 86: sa-p240nr 87: sh-h240nr 88: sa-p840ar 89: sa-p542d 90: s100i 91: e208i-p 92: e208i-a 93: e208i-c 94: e208e-p 95: p204i-b 96: p204i-c 97: p408i-p 98: p408i-a 99: p408e-p 100: p408i-c 101: p408e-m 102: p416ie-m 103: p816i-a 104: p408i-sb - name: cpqDaCntlrFWRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.3 type: DisplayString help: Array Controller Firmware Revision - 1.3.6.1.4.1.232.3.2.2.1.1.3 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrStndIntr oid: 1.3.6.1.4.1.232.3.2.2.1.1.4 type: gauge help: The status of the Standard Interface - 1.3.6.1.4.1.232.3.2.2.1.1.4 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: primary 3: secondary 4: disabled 5: unavailable - name: cpqDaCntlrSlot oid: 1.3.6.1.4.1.232.3.2.2.1.1.5 type: gauge help: Array Controller Slot - 1.3.6.1.4.1.232.3.2.2.1.1.5 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrCondition oid: 1.3.6.1.4.1.232.3.2.2.1.1.6 type: gauge help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.6 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaCntlrProductRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.7 type: DisplayString help: Array Controller Product Revision - 1.3.6.1.4.1.232.3.2.2.1.1.7 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrPartnerSlot oid: 1.3.6.1.4.1.232.3.2.2.1.1.8 type: gauge help: Array Controller Partner Slot - 1.3.6.1.4.1.232.3.2.2.1.1.8 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrCurrentRole oid: 1.3.6.1.4.1.232.3.2.2.1.1.9 type: gauge help: Array Controller Current Role - 1.3.6.1.4.1.232.3.2.2.1.1.9 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notDuplexed 3: active 4: backup 5: asymActiveActive - name: cpqDaCntlrBoardStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.10 type: gauge help: Array Controller Board Status - 1.3.6.1.4.1.232.3.2.2.1.1.10 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: generalFailure 4: cableProblem 5: poweredOff 6: cacheModuleMissing - name: cpqDaCntlrPartnerBoardStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.11 type: gauge help: Array Controller Partner Board Status - 1.3.6.1.4.1.232.3.2.2.1.1.11 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: generalFailure 4: cableProblem 5: poweredOff - name: cpqDaCntlrBoardCondition oid: 1.3.6.1.4.1.232.3.2.2.1.1.12 type: gauge help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.12 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaCntlrPartnerBoardCondition oid: 1.3.6.1.4.1.232.3.2.2.1.1.13 type: gauge help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.13 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaCntlrDriveOwnership oid: 1.3.6.1.4.1.232.3.2.2.1.1.14 type: gauge help: Array Controller Drive Ownership - 1.3.6.1.4.1.232.3.2.2.1.1.14 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: owner 3: notOwner - name: cpqDaCntlrSerialNumber oid: 1.3.6.1.4.1.232.3.2.2.1.1.15 type: DisplayString help: Array Controller Serial Number - 1.3.6.1.4.1.232.3.2.2.1.1.15 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrRedundancyType oid: 1.3.6.1.4.1.232.3.2.2.1.1.16 type: gauge help: Array Controller Redundancy Type - 1.3.6.1.4.1.232.3.2.2.1.1.16 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notRedundant 3: driverDuplexing 4: fwActiveStandby 5: fwPrimarySecondary 6: fwActiveActive - name: cpqDaCntlrRedundancyError oid: 1.3.6.1.4.1.232.3.2.2.1.1.17 type: gauge help: Array Controller Redundancy Error - 1.3.6.1.4.1.232.3.2.2.1.1.17 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: noFailure 3: noRedundantController 4: differentHardware 5: noLink 6: differentFirmware 7: differentCache 8: otherCacheFailure 9: noDrives 10: otherNoDrives 11: unsupportedDrives 12: expandInProgress - name: cpqDaCntlrAccessModuleStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.18 type: gauge help: Array Controller RAID ADG Enabler Module Status - 1.3.6.1.4.1.232.3.2.2.1.1.18 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notSupported 3: notPresent 4: badSignature 5: badChecksum 6: fullyFunctional 7: upgradeFirmware - name: cpqDaCntlrDaughterBoardType oid: 1.3.6.1.4.1.232.3.2.2.1.1.19 type: gauge help: Array Controller Daughter Board Type - 1.3.6.1.4.1.232.3.2.2.1.1.19 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notSupported 3: notPresent 4: scsiBoardPresent 5: fibreBoardPresent 6: arrayExpansionModulePresent - name: cpqDaCntlrHwLocation oid: 1.3.6.1.4.1.232.3.2.2.1.1.20 type: DisplayString help: A text description of the hardware location of the controller - 1.3.6.1.4.1.232.3.2.2.1.1.20 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrNumberOfBuses oid: 1.3.6.1.4.1.232.3.2.2.1.1.21 type: gauge help: Array Controller Number of Buses - 1.3.6.1.4.1.232.3.2.2.1.1.21 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrBlinkTime oid: 1.3.6.1.4.1.232.3.2.2.1.1.22 type: counter help: Controller Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.2.1.1.22 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrRebuildPriority oid: 1.3.6.1.4.1.232.3.2.2.1.1.23 type: gauge help: Array Controller Rebuild Priority - 1.3.6.1.4.1.232.3.2.2.1.1.23 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: low 3: medium 4: high 5: mediumHigh - name: cpqDaCntlrExpandPriority oid: 1.3.6.1.4.1.232.3.2.2.1.1.24 type: gauge help: Array Controller Expand Priority - 1.3.6.1.4.1.232.3.2.2.1.1.24 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: low 3: medium 4: high - name: cpqDaCntlrNumberOfInternalPorts oid: 1.3.6.1.4.1.232.3.2.2.1.1.25 type: gauge help: Array Controller Number of Internal Ports - 1.3.6.1.4.1.232.3.2.2.1.1.25 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrNumberOfExternalPorts oid: 1.3.6.1.4.1.232.3.2.2.1.1.26 type: gauge help: Array Controller Number of External Ports - 1.3.6.1.4.1.232.3.2.2.1.1.26 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrDriveWriteCacheState oid: 1.3.6.1.4.1.232.3.2.2.1.1.27 type: gauge help: Array Controller Drive Write Cache State - 1.3.6.1.4.1.232.3.2.2.1.1.27 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: disabled 3: enabled - name: cpqDaCntlrPartnerSerialNumber oid: 1.3.6.1.4.1.232.3.2.2.1.1.28 type: DisplayString help: Array Controller Partner Serial Number - 1.3.6.1.4.1.232.3.2.2.1.1.28 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrOptionRomRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.29 type: DisplayString help: Array Controller Option ROM Revision - 1.3.6.1.4.1.232.3.2.2.1.1.29 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrHbaFWRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.30 type: DisplayString help: Array Controller HBA Firmware Revision - 1.3.6.1.4.1.232.3.2.2.1.1.30 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrHBAModeOptionRomRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.31 type: DisplayString help: Array Controller HBA Mode Option Rom Revision - 1.3.6.1.4.1.232.3.2.2.1.1.31 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrCurrentTemp oid: 1.3.6.1.4.1.232.3.2.2.1.1.32 type: gauge help: Array Controller Current Temperature - 1.3.6.1.4.1.232.3.2.2.1.1.32 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrLastLockupCode oid: 1.3.6.1.4.1.232.3.2.2.1.1.33 type: gauge help: Array Controller Last Lockup Code - 1.3.6.1.4.1.232.3.2.2.1.1.33 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrEncryptionStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.34 type: gauge help: Array Controller Encryption Status - 1.3.6.1.4.1.232.3.2.2.1.1.34 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notEnabled 3: enabledLocalKeyMode 4: enabledRemoteKeyManagerMode - name: cpqDaCntlrASICEncptSelfTestStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.35 type: gauge help: Array Controller ASIC Encryption Self Test Status - 1.3.6.1.4.1.232.3.2.2.1.1.35 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: selfTestsPass 3: selfTestsFailed - name: cpqDaCntlrEncryptCspNvramStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.36 type: gauge help: Array Controller Encryption Critical Security Parameter NVRAM Status - 1.3.6.1.4.1.232.3.2.2.1.1.36 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: detectionFailed - name: cpqDaCntlrEncryptCryptoOfficerPwdSetStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.37 type: gauge help: Array Controller Encryption Crypto Officer Password Set Status - 1.3.6.1.4.1.232.3.2.2.1.1.37 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrEncryptCntlrPwdSetStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.38 type: gauge help: Array Controller Encryption Controller Password Set Status - 1.3.6.1.4.1.232.3.2.2.1.1.38 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrEncryptCntlrPwdAvailStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.39 type: gauge help: Array Controller Encryption Controller Password Availability Status - 1.3.6.1.4.1.232.3.2.2.1.1.39 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: passwordMissing 3: passwordActive - name: cpqDaCntlrUnencryptedLogDrvCreationPolicy oid: 1.3.6.1.4.1.232.3.2.2.1.1.40 type: gauge help: Array Controller Unencrypted Logical Drive Creation Policy - 1.3.6.1.4.1.232.3.2.2.1.1.40 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrEncryptedLogDrvCreationPolicy oid: 1.3.6.1.4.1.232.3.2.2.1.1.41 type: gauge help: Array Controller Encrypted Logical Drive Creation Policy - 1.3.6.1.4.1.232.3.2.2.1.1.41 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrEncryptFWLockStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.42 type: gauge help: Array Controller Encryption Firmware Lock Status - 1.3.6.1.4.1.232.3.2.2.1.1.42 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrOperatingMode oid: 1.3.6.1.4.1.232.3.2.2.1.1.43 type: gauge help: Array Controller Operating Mode - 1.3.6.1.4.1.232.3.2.2.1.1.43 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: smartArrayMode 3: smartHbaMode 4: mixedMode - name: cpqDaLogDrvCntlrIndex oid: 1.3.6.1.4.1.232.3.2.3.1.1.1 type: gauge help: Drive Array Logical Drive Controller Index - 1.3.6.1.4.1.232.3.2.3.1.1.1 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvIndex oid: 1.3.6.1.4.1.232.3.2.3.1.1.2 type: gauge help: Drive Array Logical Drive Index - 1.3.6.1.4.1.232.3.2.3.1.1.2 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvFaultTol oid: 1.3.6.1.4.1.232.3.2.3.1.1.3 type: gauge help: Logical Drive Fault Tolerance - 1.3.6.1.4.1.232.3.2.3.1.1.3 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: none 3: mirroring 4: dataGuard 5: distribDataGuard 7: advancedDataGuard 8: raid50 9: raid60 10: raid1Adm 11: raid10Adm 12: raid10 - name: cpqDaLogDrvStatus oid: 1.3.6.1.4.1.232.3.2.3.1.1.4 type: gauge help: Logical Drive Status - 1.3.6.1.4.1.232.3.2.3.1.1.4 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: unconfigured 5: recovering 6: readyForRebuild 7: rebuilding 8: wrongDrive 9: badConnect 10: overheating 11: shutdown 12: expanding 13: notAvailable 14: queuedForExpansion 15: multipathAccessDegraded 16: erasing 17: predictiveSpareRebuildReady 18: rapidParityInitInProgress 19: rapidParityInitPending 20: noAccessEncryptedNoCntlrKey 21: unencryptedToEncryptedInProgress 22: newLogDrvKeyRekeyInProgress 23: noAccessEncryptedCntlrEncryptnNotEnbld 24: unencryptedToEncryptedNotStarted 25: newLogDrvKeyRekeyRequestReceived - name: cpqDaLogDrvAutoRel oid: 1.3.6.1.4.1.232.3.2.3.1.1.5 type: gauge help: Array Controller Logical Drive Auto-Reliability Delay - 1.3.6.1.4.1.232.3.2.3.1.1.5 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvRebuildBlks oid: 1.3.6.1.4.1.232.3.2.3.1.1.6 type: counter help: Logical Drive Rebuild Blocks Remaining - 1.3.6.1.4.1.232.3.2.3.1.1.6 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvHasAccel oid: 1.3.6.1.4.1.232.3.2.3.1.1.7 type: gauge help: Logical Drive Has Cache Module Board - 1.3.6.1.4.1.232.3.2.3.1.1.7 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: unavailable 3: enabled 4: disabled - name: cpqDaLogDrvAvailSpares oid: 1.3.6.1.4.1.232.3.2.3.1.1.8 type: OctetString help: Drive Array Logical Drive Available Spares - 1.3.6.1.4.1.232.3.2.3.1.1.8 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvSize oid: 1.3.6.1.4.1.232.3.2.3.1.1.9 type: gauge help: Logical Drive Size - 1.3.6.1.4.1.232.3.2.3.1.1.9 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvPhyDrvIDs oid: 1.3.6.1.4.1.232.3.2.3.1.1.10 type: OctetString help: Drive Array Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.3.2.3.1.1.10 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvCondition oid: 1.3.6.1.4.1.232.3.2.3.1.1.11 type: gauge help: The Logical Drive condition - 1.3.6.1.4.1.232.3.2.3.1.1.11 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaLogDrvPercentRebuild oid: 1.3.6.1.4.1.232.3.2.3.1.1.12 type: gauge help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.3.2.3.1.1.12 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvStripeSize oid: 1.3.6.1.4.1.232.3.2.3.1.1.13 type: gauge help: Logical Drive Stripe Size - 1.3.6.1.4.1.232.3.2.3.1.1.13 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvOsName oid: 1.3.6.1.4.1.232.3.2.3.1.1.14 type: DisplayString help: Logical Drive OS Name - 1.3.6.1.4.1.232.3.2.3.1.1.14 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvBlinkTime oid: 1.3.6.1.4.1.232.3.2.3.1.1.15 type: counter help: Logical Drive Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.3.1.1.15 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvSpareReplaceMap oid: 1.3.6.1.4.1.232.3.2.3.1.1.16 type: OctetString help: Logical Drive Spare To Replacement Drive Map - 1.3.6.1.4.1.232.3.2.3.1.1.16 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvRebuildingPhyDrv oid: 1.3.6.1.4.1.232.3.2.3.1.1.17 type: gauge help: Logical Drive Physical Drive Rebuilding Index - 1.3.6.1.4.1.232.3.2.3.1.1.17 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvMultipathAccess oid: 1.3.6.1.4.1.232.3.2.3.1.1.18 type: gauge help: Logical Drive Multi-path Access - 1.3.6.1.4.1.232.3.2.3.1.1.18 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: notSupported 3: notConfigured 4: pathRedundant 5: noRedundantPath - name: cpqDaLogDrvNmbrOfParityGroups oid: 1.3.6.1.4.1.232.3.2.3.1.1.19 type: gauge help: Logical Drive Number Of Parity Groups - 1.3.6.1.4.1.232.3.2.3.1.1.19 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvSplitMirrorBackupLogDrv oid: 1.3.6.1.4.1.232.3.2.3.1.1.20 type: gauge help: Logical Drive Split Mirror Backup Logical Drive - 1.3.6.1.4.1.232.3.2.3.1.1.20 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: isNotBackupLogicalDrive 3: isBackupLogicalDrive - name: cpqDaLogDrvCacheVolAccelAssocType oid: 1.3.6.1.4.1.232.3.2.3.1.1.21 type: gauge help: Logical Drive Cache Volume Accelerator Association Type - 1.3.6.1.4.1.232.3.2.3.1.1.21 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: nonMember 3: logicalDriveMember 4: cacheVolumeMember - name: cpqDaLogDrvCacheVolIndex oid: 1.3.6.1.4.1.232.3.2.3.1.1.22 type: gauge help: Logical Drive Cache Volume Index - 1.3.6.1.4.1.232.3.2.3.1.1.22 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvRPIPercentComplete oid: 1.3.6.1.4.1.232.3.2.3.1.1.23 type: gauge help: Logical Drive Rapid Parity Initialization Percent Complete - 1.3.6.1.4.1.232.3.2.3.1.1.23 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvSSDSmartPathStatus oid: 1.3.6.1.4.1.232.3.2.3.1.1.24 type: gauge help: Logical Drive SSD Smart Path Status - 1.3.6.1.4.1.232.3.2.3.1.1.24 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: updateDriver 3: ssdSmartPathDisabled 4: ssdSmartPathEnabled - name: cpqDaLogDrvEncryptionStatus oid: 1.3.6.1.4.1.232.3.2.3.1.1.25 type: gauge help: Logical Drive Encryption Status - 1.3.6.1.4.1.232.3.2.3.1.1.25 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: encrypted 3: notEncrypted - name: cpqDaPhyDrvCntlrIndex oid: 1.3.6.1.4.1.232.3.2.5.1.1.1 type: gauge help: Drive Array Physical Drive Controller Index - 1.3.6.1.4.1.232.3.2.5.1.1.1 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvIndex oid: 1.3.6.1.4.1.232.3.2.5.1.1.2 type: gauge help: Drive Array Physical Drive Index - 1.3.6.1.4.1.232.3.2.5.1.1.2 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvModel oid: 1.3.6.1.4.1.232.3.2.5.1.1.3 type: DisplayString help: Physical Drive Model - 1.3.6.1.4.1.232.3.2.5.1.1.3 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFWRev oid: 1.3.6.1.4.1.232.3.2.5.1.1.4 type: DisplayString help: Physical Drive Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.4 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBay oid: 1.3.6.1.4.1.232.3.2.5.1.1.5 type: gauge help: Physical Drive Bay Location - 1.3.6.1.4.1.232.3.2.5.1.1.5 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.6 type: gauge help: Physical Drive Status - 1.3.6.1.4.1.232.3.2.5.1.1.6 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: predictiveFailure 5: erasing 6: eraseDone 7: eraseQueued 8: ssdWearOut 9: notAuthenticated - name: cpqDaPhyDrvFactReallocs oid: 1.3.6.1.4.1.232.3.2.5.1.1.7 type: gauge help: This shows the number of spare sectors available for remapping at the time the physical drive was shipped - 1.3.6.1.4.1.232.3.2.5.1.1.7 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvUsedReallocs oid: 1.3.6.1.4.1.232.3.2.5.1.1.8 type: counter help: Physical Drive Used Reallocated Sectors - 1.3.6.1.4.1.232.3.2.5.1.1.8 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvRefHours oid: 1.3.6.1.4.1.232.3.2.5.1.1.9 type: counter help: Reference Time in hours - 1.3.6.1.4.1.232.3.2.5.1.1.9 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHReads oid: 1.3.6.1.4.1.232.3.2.5.1.1.10 type: counter help: Sectors Read (high) - 1.3.6.1.4.1.232.3.2.5.1.1.10 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvReads oid: 1.3.6.1.4.1.232.3.2.5.1.1.11 type: counter help: Sectors Read (low) - 1.3.6.1.4.1.232.3.2.5.1.1.11 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHWrites oid: 1.3.6.1.4.1.232.3.2.5.1.1.12 type: counter help: Sectors Written (high) - 1.3.6.1.4.1.232.3.2.5.1.1.12 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvWrites oid: 1.3.6.1.4.1.232.3.2.5.1.1.13 type: counter help: Sectors Written (low) - 1.3.6.1.4.1.232.3.2.5.1.1.13 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHSeeks oid: 1.3.6.1.4.1.232.3.2.5.1.1.14 type: counter help: Total Seeks (high) - 1.3.6.1.4.1.232.3.2.5.1.1.14 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSeeks oid: 1.3.6.1.4.1.232.3.2.5.1.1.15 type: counter help: Total Seeks (low) - 1.3.6.1.4.1.232.3.2.5.1.1.15 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHardReadErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.16 type: counter help: Hard Read Errors - 1.3.6.1.4.1.232.3.2.5.1.1.16 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvRecvReadErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.17 type: counter help: Recovered Read Errors - 1.3.6.1.4.1.232.3.2.5.1.1.17 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHardWriteErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.18 type: counter help: Hard Write Errors - 1.3.6.1.4.1.232.3.2.5.1.1.18 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvRecvWriteErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.19 type: counter help: Recovered Write Errors - 1.3.6.1.4.1.232.3.2.5.1.1.19 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHSeekErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.20 type: counter help: Seek Errors (High) - 1.3.6.1.4.1.232.3.2.5.1.1.20 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSeekErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.21 type: counter help: Seek Errors (low) - 1.3.6.1.4.1.232.3.2.5.1.1.21 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSpinupTime oid: 1.3.6.1.4.1.232.3.2.5.1.1.22 type: gauge help: Spin up Time in tenths of seconds - 1.3.6.1.4.1.232.3.2.5.1.1.22 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFunctTest1 oid: 1.3.6.1.4.1.232.3.2.5.1.1.23 type: gauge help: Functional Test 1 - 1.3.6.1.4.1.232.3.2.5.1.1.23 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFunctTest2 oid: 1.3.6.1.4.1.232.3.2.5.1.1.24 type: gauge help: Functional Test 2 - 1.3.6.1.4.1.232.3.2.5.1.1.24 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFunctTest3 oid: 1.3.6.1.4.1.232.3.2.5.1.1.25 type: gauge help: Functional Test 3 - 1.3.6.1.4.1.232.3.2.5.1.1.25 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvDrqTimeouts oid: 1.3.6.1.4.1.232.3.2.5.1.1.26 type: counter help: DRQ Timeouts - 1.3.6.1.4.1.232.3.2.5.1.1.26 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvOtherTimeouts oid: 1.3.6.1.4.1.232.3.2.5.1.1.27 type: counter help: Other Timeouts - 1.3.6.1.4.1.232.3.2.5.1.1.27 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSpinupRetries oid: 1.3.6.1.4.1.232.3.2.5.1.1.28 type: counter help: Spin up Retries - 1.3.6.1.4.1.232.3.2.5.1.1.28 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBadRecvReads oid: 1.3.6.1.4.1.232.3.2.5.1.1.29 type: counter help: Recovery Failed (Bad) Read Error - 1.3.6.1.4.1.232.3.2.5.1.1.29 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBadRecvWrites oid: 1.3.6.1.4.1.232.3.2.5.1.1.30 type: counter help: Recovery Failed (Bad) Write Error - 1.3.6.1.4.1.232.3.2.5.1.1.30 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFormatErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.31 type: counter help: Format Error - 1.3.6.1.4.1.232.3.2.5.1.1.31 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvPostErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.32 type: counter help: Power On Self Test (Post) Error - 1.3.6.1.4.1.232.3.2.5.1.1.32 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvNotReadyErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.33 type: counter help: Drive Not Ready Errors - 1.3.6.1.4.1.232.3.2.5.1.1.33 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvReallocAborts oid: 1.3.6.1.4.1.232.3.2.5.1.1.34 type: counter help: Physical Drive Reallocation Aborts - 1.3.6.1.4.1.232.3.2.5.1.1.34 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvThreshPassed oid: 1.3.6.1.4.1.232.3.2.5.1.1.35 type: gauge help: Physical Drive Factory Threshold Passed (Exceeded) - 1.3.6.1.4.1.232.3.2.5.1.1.35 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: "false" 2: "true" - name: cpqDaPhyDrvHasMonInfo oid: 1.3.6.1.4.1.232.3.2.5.1.1.36 type: gauge help: Physical Drive Has Monitor Information - 1.3.6.1.4.1.232.3.2.5.1.1.36 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: "false" 2: "true" - name: cpqDaPhyDrvCondition oid: 1.3.6.1.4.1.232.3.2.5.1.1.37 type: gauge help: The condition of the device - 1.3.6.1.4.1.232.3.2.5.1.1.37 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaPhyDrvHotPlugs oid: 1.3.6.1.4.1.232.3.2.5.1.1.38 type: counter help: Physical Drive Hot Plug Count - 1.3.6.1.4.1.232.3.2.5.1.1.38 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvMediaErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.39 type: counter help: Physical Drive Media Failure Count - 1.3.6.1.4.1.232.3.2.5.1.1.39 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHardwareErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.40 type: counter help: Physical Drive Hardware Error Count - 1.3.6.1.4.1.232.3.2.5.1.1.40 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvAbortedCmds oid: 1.3.6.1.4.1.232.3.2.5.1.1.41 type: counter help: Physical Drive Aborted Command Failures - 1.3.6.1.4.1.232.3.2.5.1.1.41 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSpinUpErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.42 type: counter help: Physical Drive Spin-Up Failure Count - 1.3.6.1.4.1.232.3.2.5.1.1.42 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBadTargetErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.43 type: counter help: Physical Drive Bad Target Count - 1.3.6.1.4.1.232.3.2.5.1.1.43 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvLocation oid: 1.3.6.1.4.1.232.3.2.5.1.1.44 type: gauge help: Drive Physical Location - 1.3.6.1.4.1.232.3.2.5.1.1.44 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: internal 3: external 4: proLiant - name: cpqDaPhyDrvSize oid: 1.3.6.1.4.1.232.3.2.5.1.1.45 type: gauge help: Physical Drive Size in MB - 1.3.6.1.4.1.232.3.2.5.1.1.45 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBusFaults oid: 1.3.6.1.4.1.232.3.2.5.1.1.46 type: counter help: Physical Drive Bus Fault Count - 1.3.6.1.4.1.232.3.2.5.1.1.46 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvIrqDeglitches oid: 1.3.6.1.4.1.232.3.2.5.1.1.47 type: counter help: Physical Drive IRQ Deglitch Count - 1.3.6.1.4.1.232.3.2.5.1.1.47 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHotPlug oid: 1.3.6.1.4.1.232.3.2.5.1.1.48 type: gauge help: Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.3.2.5.1.1.48 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: hotPlug 3: nonHotPlug - name: cpqDaPhyDrvPlacement oid: 1.3.6.1.4.1.232.3.2.5.1.1.49 type: gauge help: Physical Drive Placement - 1.3.6.1.4.1.232.3.2.5.1.1.49 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: internal 3: external - name: cpqDaPhyDrvBusNumber oid: 1.3.6.1.4.1.232.3.2.5.1.1.50 type: gauge help: Physical Drive SCSI Bus Number - 1.3.6.1.4.1.232.3.2.5.1.1.50 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSerialNum oid: 1.3.6.1.4.1.232.3.2.5.1.1.51 type: DisplayString help: Physical Drive Serial Number - 1.3.6.1.4.1.232.3.2.5.1.1.51 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvPreFailMonitoring oid: 1.3.6.1.4.1.232.3.2.5.1.1.52 type: gauge help: Drive Array Physical Drive Predictive Failure Monitoring - 1.3.6.1.4.1.232.3.2.5.1.1.52 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: notAvailable 3: available - name: cpqDaPhyDrvCurrentWidth oid: 1.3.6.1.4.1.232.3.2.5.1.1.53 type: gauge help: Drive Array Physical Drive Current Width - 1.3.6.1.4.1.232.3.2.5.1.1.53 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: narrow 3: wide16 - name: cpqDaPhyDrvCurrentSpeed oid: 1.3.6.1.4.1.232.3.2.5.1.1.54 type: gauge help: Drive Array Physical Drive Current Data Transfer Speed - 1.3.6.1.4.1.232.3.2.5.1.1.54 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: asynchronous 3: fast 4: ultra 5: ultra2 6: ultra3 7: ultra320 - name: cpqDaPhyDrvFailureCode oid: 1.3.6.1.4.1.232.3.2.5.1.1.55 type: gauge help: Drive Array Physical Drive Failure Code - 1.3.6.1.4.1.232.3.2.5.1.1.55 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBlinkTime oid: 1.3.6.1.4.1.232.3.2.5.1.1.56 type: counter help: Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.5.1.1.56 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSmartStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.57 type: gauge help: Physical Drive S.M.A.R.T Status - 1.3.6.1.4.1.232.3.2.5.1.1.57 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: replaceDrive 4: replaceDriveSSDWearOut - name: cpqDaPhyDrvConfigurationStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.58 type: gauge help: Physical Drive Configuration Status - 1.3.6.1.4.1.232.3.2.5.1.1.58 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: configured 3: notConfigured - name: cpqDaPhyDrvRotationalSpeed oid: 1.3.6.1.4.1.232.3.2.5.1.1.59 type: gauge help: Drive Array Physical Drive Rotational Speed - 1.3.6.1.4.1.232.3.2.5.1.1.59 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: rpm7200 3: rpm10K 4: rpm15K 5: rpmSsd - name: cpqDaPhyDrvType oid: 1.3.6.1.4.1.232.3.2.5.1.1.60 type: gauge help: Physical Drive Type - 1.3.6.1.4.1.232.3.2.5.1.1.60 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: parallelScsi 3: sata 4: sas - name: cpqDaPhyDrvSataVersion oid: 1.3.6.1.4.1.232.3.2.5.1.1.61 type: gauge help: Physical Drive SATA Version - 1.3.6.1.4.1.232.3.2.5.1.1.61 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: sataOne 3: sataTwo - name: cpqDaPhyDrvHostConnector oid: 1.3.6.1.4.1.232.3.2.5.1.1.62 type: DisplayString help: Physical Drive Host Connector - 1.3.6.1.4.1.232.3.2.5.1.1.62 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBoxOnConnector oid: 1.3.6.1.4.1.232.3.2.5.1.1.63 type: gauge help: Physical Drive Box on Connector - 1.3.6.1.4.1.232.3.2.5.1.1.63 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvLocationString oid: 1.3.6.1.4.1.232.3.2.5.1.1.64 type: DisplayString help: Physical Drive Location String - 1.3.6.1.4.1.232.3.2.5.1.1.64 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvNegotiatedLinkRate oid: 1.3.6.1.4.1.232.3.2.5.1.1.65 type: gauge help: Drive Array Physical Drive Negotiated Link Rate - 1.3.6.1.4.1.232.3.2.5.1.1.65 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: rate-1-5 3: rate-3-0 4: rate-6-0 5: rate-12-0 - name: cpqDaPhyDrvNcqSupport oid: 1.3.6.1.4.1.232.3.2.5.1.1.66 type: gauge help: Drive Array Physical Drive Native Command Queueing - 1.3.6.1.4.1.232.3.2.5.1.1.66 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: noControllerSupport 3: noDriveSupport 4: ncqDisabled 5: ncqEnabled - name: cpqDaPhyDrvPhyCount oid: 1.3.6.1.4.1.232.3.2.5.1.1.67 type: gauge help: Drive Array Physical Drive PHY Count - 1.3.6.1.4.1.232.3.2.5.1.1.67 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvMultipathAccess oid: 1.3.6.1.4.1.232.3.2.5.1.1.68 type: gauge help: Drive Array Physical Drive Multi-path Access Status - 1.3.6.1.4.1.232.3.2.5.1.1.68 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: notSupported 3: notConfigured 4: pathRedundant 5: noRedundantPath 6: driveFailed - name: cpqDaPhyDrvMediaType oid: 1.3.6.1.4.1.232.3.2.5.1.1.69 type: gauge help: Drive Array Physical Drive Media Type - 1.3.6.1.4.1.232.3.2.5.1.1.69 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: rotatingPlatters 3: solidState 4: smr - name: cpqDaPhyDrvCurrentTemperature oid: 1.3.6.1.4.1.232.3.2.5.1.1.70 type: gauge help: Drive Array Physical Drive Current Temperature - 1.3.6.1.4.1.232.3.2.5.1.1.70 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvTemperatureThreshold oid: 1.3.6.1.4.1.232.3.2.5.1.1.71 type: gauge help: Drive Array Physical Drive Temperature Threshold - 1.3.6.1.4.1.232.3.2.5.1.1.71 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvMaximumTemperature oid: 1.3.6.1.4.1.232.3.2.5.1.1.72 type: gauge help: Drive Array Physical Drive Maximum Temperature - 1.3.6.1.4.1.232.3.2.5.1.1.72 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSSDWearStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.73 type: gauge help: Drive Array Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.3.2.5.1.1.73 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: fiftySixDayThreshold 4: fivePercentThreshold 5: twoPercentThreshold 6: ssdWearOut - name: cpqDaPhyDrvPowerOnHours oid: 1.3.6.1.4.1.232.3.2.5.1.1.74 type: counter help: Drive Array Physical Drive Power On Hours - 1.3.6.1.4.1.232.3.2.5.1.1.74 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSSDPercntEndrnceUsed oid: 1.3.6.1.4.1.232.3.2.5.1.1.75 type: gauge help: Drive Array Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.3.2.5.1.1.75 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSSDEstTimeRemainingHours oid: 1.3.6.1.4.1.232.3.2.5.1.1.76 type: counter help: Drive Array Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.3.2.5.1.1.76 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvAuthenticationStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.77 type: gauge help: Drive Array Physical Drive Authentication Status - 1.3.6.1.4.1.232.3.2.5.1.1.77 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: notSupported 3: authenticationFailed 4: authenticationPassed - name: cpqDaPhyDrvSmartCarrierAppFWRev oid: 1.3.6.1.4.1.232.3.2.5.1.1.78 type: gauge help: Physical Drive Smart Carrier Application Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.78 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSmartCarrierBootldrFWRev oid: 1.3.6.1.4.1.232.3.2.5.1.1.79 type: gauge help: Physical Drive Smart Carrier Bootloader Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.79 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvEncryptionStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.80 type: gauge help: Physical Drive Encryption Status - 1.3.6.1.4.1.232.3.2.5.1.1.80 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: encrypted 3: notEncrypted - name: cpqScsiMibRevMajor oid: 1.3.6.1.4.1.232.5.1.1 type: gauge help: The Major Revision level - 1.3.6.1.4.1.232.5.1.1 - name: cpqScsiMibRevMinor oid: 1.3.6.1.4.1.232.5.1.2 type: gauge help: The Minor Revision level - 1.3.6.1.4.1.232.5.1.2 - name: cpqScsiMibCondition oid: 1.3.6.1.4.1.232.5.1.3 type: gauge help: The overall condition - 1.3.6.1.4.1.232.5.1.3 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqScsiNw3xDriverName oid: 1.3.6.1.4.1.232.5.2.1.1.1 type: DisplayString help: SCSI Drive Device Driver Name - 1.3.6.1.4.1.232.5.2.1.1.1 - name: cpqScsiNw3xDriverVers oid: 1.3.6.1.4.1.232.5.2.1.1.2 type: DisplayString help: SCSI Drive Device Driver Version - 1.3.6.1.4.1.232.5.2.1.1.2 - name: cpqScsiNw3xDriverPollType oid: 1.3.6.1.4.1.232.5.2.1.1.3 type: gauge help: SCSI Drive Device Driver Poll Type - 1.3.6.1.4.1.232.5.2.1.1.3 enum_values: 1: other 2: polled 3: demand - name: cpqScsiNw3xDriverPollTime oid: 1.3.6.1.4.1.232.5.2.1.1.4 type: gauge help: SCSI Drive Device Driver Poll Time - 1.3.6.1.4.1.232.5.2.1.1.4 - name: cpqScsiNw3xCntlrIndex oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.1 type: gauge help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.1.1.5.1.1 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xBusIndex oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.2 type: gauge help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.5.1.2 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xXptDesc oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.3 type: DisplayString help: SCSI XPT Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.3 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xXptVers oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.4 type: DisplayString help: SCSI XPT Version - 1.3.6.1.4.1.232.5.2.1.1.5.1.4 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xSimDesc oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.5 type: DisplayString help: SCSI SIM Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.5 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xSimVers oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.6 type: DisplayString help: SCSI SIM Version - 1.3.6.1.4.1.232.5.2.1.1.5.1.6 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xHbaDesc oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.7 type: DisplayString help: SCSI HBA Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.7 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xStatCntlrIndex oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.1 type: gauge help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.1 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xStatBusIndex oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.2 type: gauge help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.2 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xStatLogDrvIndex oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.3 type: gauge help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.3 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xTotalReads oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.4 type: counter help: SCSI Logical Drive Total Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.4 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xTotalWrites oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.5 type: counter help: SCSI Logical Drive Total Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.5 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xCorrReads oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.6 type: counter help: SCSI Logical Drive Corrected Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.6 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xCorrWrites oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.7 type: counter help: SCSI Logical Drive Corrected Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.7 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xFatalReads oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.8 type: counter help: SCSI Logical Drive Fatal Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.8 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xFatalWrites oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.9 type: counter help: SCSI Logical Drive Fatal Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.9 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xVolCntlrIndex oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.1 type: gauge help: SCSI Cntlr Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.1 indexes: - labelname: cpqScsiNw3xVolCntlrIndex type: gauge - labelname: cpqScsiNw3xVolBusIndex type: gauge - labelname: cpqScsiNw3xVolLogDrvIndex type: gauge - name: cpqScsiNw3xVolBusIndex oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.2 type: gauge help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.2 indexes: - labelname: cpqScsiNw3xVolCntlrIndex type: gauge - labelname: cpqScsiNw3xVolBusIndex type: gauge - labelname: cpqScsiNw3xVolLogDrvIndex type: gauge - name: cpqScsiNw3xVolLogDrvIndex oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.3 type: gauge help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.3 indexes: - labelname: cpqScsiNw3xVolCntlrIndex type: gauge - labelname: cpqScsiNw3xVolBusIndex type: gauge - labelname: cpqScsiNw3xVolLogDrvIndex type: gauge - name: cpqScsiNw3xVolMap oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.4 type: OctetString help: SCSI Drive Volume Map - 1.3.6.1.4.1.232.5.2.1.1.7.1.4 indexes: - labelname: cpqScsiNw3xVolCntlrIndex type: gauge - labelname: cpqScsiNw3xVolBusIndex type: gauge - labelname: cpqScsiNw3xVolLogDrvIndex type: gauge - name: cpqScsiOsCommonPollFreq oid: 1.3.6.1.4.1.232.5.2.1.4.1 type: gauge help: The agent`s polling frequency - 1.3.6.1.4.1.232.5.2.1.4.1 - name: cpqScsiOsCommonModuleIndex oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.1 type: gauge help: A unique index for this module description. - 1.3.6.1.4.1.232.5.2.1.4.2.1.1 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiOsCommonModuleName oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.2 type: DisplayString help: The module name. - 1.3.6.1.4.1.232.5.2.1.4.2.1.2 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiOsCommonModuleVersion oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.3 type: DisplayString help: The module version in XX.YY format - 1.3.6.1.4.1.232.5.2.1.4.2.1.3 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiOsCommonModuleDate oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.4 type: OctetString help: The module date - 1.3.6.1.4.1.232.5.2.1.4.2.1.4 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiOsCommonModulePurpose oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.5 type: DisplayString help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.5.2.1.4.2.1.5 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiCntlrIndex oid: 1.3.6.1.4.1.232.5.2.2.1.1.1 type: gauge help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.2.1.1.1 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrBusIndex oid: 1.3.6.1.4.1.232.5.2.2.1.1.2 type: gauge help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.2.1.1.2 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrModel oid: 1.3.6.1.4.1.232.5.2.2.1.1.3 type: gauge help: SCSI Controller Model - 1.3.6.1.4.1.232.5.2.2.1.1.3 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge enum_values: 1: other 2: cpqs710 3: cpqs94 4: cpqs810p 5: cpqs825e 6: cpqs825p 7: cpqs974p 8: cpqs875p 9: extended 10: cpqs895p 11: cpqs896p 12: cpqa789x 13: cpqs876t 14: hpu320 15: hpu320r 16: generic 17: hp1u320g2 18: hp1u320g1 19: hpSc11Xe - name: cpqScsiCntlrFWVers oid: 1.3.6.1.4.1.232.5.2.2.1.1.4 type: DisplayString help: SCSI Controller Firmware Version - 1.3.6.1.4.1.232.5.2.2.1.1.4 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrSWVers oid: 1.3.6.1.4.1.232.5.2.2.1.1.5 type: DisplayString help: SCSI Controller Software Version - 1.3.6.1.4.1.232.5.2.2.1.1.5 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrSlot oid: 1.3.6.1.4.1.232.5.2.2.1.1.6 type: gauge help: SCSI Controller Slot - 1.3.6.1.4.1.232.5.2.2.1.1.6 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrStatus oid: 1.3.6.1.4.1.232.5.2.2.1.1.7 type: gauge help: SCSI Controller Status - 1.3.6.1.4.1.232.5.2.2.1.1.7 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge enum_values: 1: other 2: ok 3: failed - name: cpqScsiCntlrHardResets oid: 1.3.6.1.4.1.232.5.2.2.1.1.8 type: counter help: SCSI Controller Hard Resets - 1.3.6.1.4.1.232.5.2.2.1.1.8 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrSoftResets oid: 1.3.6.1.4.1.232.5.2.2.1.1.9 type: counter help: SCSI Controller Soft Resets - 1.3.6.1.4.1.232.5.2.2.1.1.9 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrTimeouts oid: 1.3.6.1.4.1.232.5.2.2.1.1.10 type: counter help: SCSI Controller Time-outs - 1.3.6.1.4.1.232.5.2.2.1.1.10 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrBaseIOAddr oid: 1.3.6.1.4.1.232.5.2.2.1.1.11 type: gauge help: SCSI Controller Base I/O Address - 1.3.6.1.4.1.232.5.2.2.1.1.11 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrCondition oid: 1.3.6.1.4.1.232.5.2.2.1.1.12 type: gauge help: SCSI Controller Condition - 1.3.6.1.4.1.232.5.2.2.1.1.12 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqScsiCntlrSerialNum oid: 1.3.6.1.4.1.232.5.2.2.1.1.13 type: DisplayString help: SCSI Controller Serial Number - 1.3.6.1.4.1.232.5.2.2.1.1.13 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrBusWidth oid: 1.3.6.1.4.1.232.5.2.2.1.1.14 type: gauge help: SCSI Controller Data Bus Width - 1.3.6.1.4.1.232.5.2.2.1.1.14 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge enum_values: 1: other 2: narrow 3: wide16 - name: cpqScsiCntlrModelExtended oid: 1.3.6.1.4.1.232.5.2.2.1.1.15 type: DisplayString help: SCSI Controller Model Name - 1.3.6.1.4.1.232.5.2.2.1.1.15 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrHwLocation oid: 1.3.6.1.4.1.232.5.2.2.1.1.16 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the SCSI controller - 1.3.6.1.4.1.232.5.2.2.1.1.16 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrPciLocation oid: 1.3.6.1.4.1.232.5.2.2.1.1.17 type: DisplayString help: A string designating the PCI device location for the controller, following the format DDDD:BB:DD.F, where DDDD is the PCI domain number, BB is the PCI bus number, DD is the PCI device number, and F is the PCI function number - 1.3.6.1.4.1.232.5.2.2.1.1.17 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiLogDrvCntlrIndex oid: 1.3.6.1.4.1.232.5.2.3.1.1.1 type: gauge help: SCSI Logical Drive Controller Index - 1.3.6.1.4.1.232.5.2.3.1.1.1 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvBusIndex oid: 1.3.6.1.4.1.232.5.2.3.1.1.2 type: gauge help: SCSI Logical Drive Bus Index - 1.3.6.1.4.1.232.5.2.3.1.1.2 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvIndex oid: 1.3.6.1.4.1.232.5.2.3.1.1.3 type: gauge help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.3.1.1.3 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvFaultTol oid: 1.3.6.1.4.1.232.5.2.3.1.1.4 type: gauge help: SCSI Logical Drive Fault Tolerance - 1.3.6.1.4.1.232.5.2.3.1.1.4 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge enum_values: 1: other 2: none 3: mirroring 4: dataGuard 5: distribDataGuard 6: enhancedMirroring - name: cpqScsiLogDrvStatus oid: 1.3.6.1.4.1.232.5.2.3.1.1.5 type: gauge help: SCSI Logical Drive Status - 1.3.6.1.4.1.232.5.2.3.1.1.5 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: unconfigured 5: recovering 6: readyForRebuild 7: rebuilding 8: wrongDrive 9: badConnect 10: degraded 11: disabled - name: cpqScsiLogDrvSize oid: 1.3.6.1.4.1.232.5.2.3.1.1.6 type: gauge help: SCSI Logical Drive Size - 1.3.6.1.4.1.232.5.2.3.1.1.6 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvPhyDrvIDs oid: 1.3.6.1.4.1.232.5.2.3.1.1.7 type: OctetString help: SCSI Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.5.2.3.1.1.7 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvCondition oid: 1.3.6.1.4.1.232.5.2.3.1.1.8 type: gauge help: SCSI Logical Drive Condition - 1.3.6.1.4.1.232.5.2.3.1.1.8 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqScsiLogDrvStripeSize oid: 1.3.6.1.4.1.232.5.2.3.1.1.9 type: gauge help: Logical Drive Stripe Size - 1.3.6.1.4.1.232.5.2.3.1.1.9 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvAvailSpares oid: 1.3.6.1.4.1.232.5.2.3.1.1.10 type: OctetString help: SCSI Logical Drive Available Spares - 1.3.6.1.4.1.232.5.2.3.1.1.10 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvPercentRebuild oid: 1.3.6.1.4.1.232.5.2.3.1.1.11 type: gauge help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.5.2.3.1.1.11 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvOsName oid: 1.3.6.1.4.1.232.5.2.3.1.1.12 type: DisplayString help: Logical Drive OS Name - 1.3.6.1.4.1.232.5.2.3.1.1.12 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiPhyDrvCntlrIndex oid: 1.3.6.1.4.1.232.5.2.4.1.1.1 type: gauge help: SCSI Physical Drive Controller Index - 1.3.6.1.4.1.232.5.2.4.1.1.1 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvBusIndex oid: 1.3.6.1.4.1.232.5.2.4.1.1.2 type: gauge help: SCSI Physical Drive Bus Index - 1.3.6.1.4.1.232.5.2.4.1.1.2 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvIndex oid: 1.3.6.1.4.1.232.5.2.4.1.1.3 type: gauge help: SCSI Physical Drive Index - 1.3.6.1.4.1.232.5.2.4.1.1.3 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvModel oid: 1.3.6.1.4.1.232.5.2.4.1.1.4 type: DisplayString help: SCSI Physical Drive Model - 1.3.6.1.4.1.232.5.2.4.1.1.4 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvFWRev oid: 1.3.6.1.4.1.232.5.2.4.1.1.5 type: DisplayString help: SCSI Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.2.4.1.1.5 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvVendor oid: 1.3.6.1.4.1.232.5.2.4.1.1.6 type: DisplayString help: SCSI Physical Drive Vendor - 1.3.6.1.4.1.232.5.2.4.1.1.6 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvSize oid: 1.3.6.1.4.1.232.5.2.4.1.1.7 type: gauge help: SCSI Physical Drive Size in MB - 1.3.6.1.4.1.232.5.2.4.1.1.7 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvScsiID oid: 1.3.6.1.4.1.232.5.2.4.1.1.8 type: gauge help: SCSI Physical Drive SCSI ID - 1.3.6.1.4.1.232.5.2.4.1.1.8 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvStatus oid: 1.3.6.1.4.1.232.5.2.4.1.1.9 type: gauge help: SCSI Physical Drive Status - 1.3.6.1.4.1.232.5.2.4.1.1.9 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: notConfigured 5: badCable 6: missingWasOk 7: missingWasFailed 8: predictiveFailure 9: missingWasPredictiveFailure 10: offline 11: missingWasOffline 12: hardError - name: cpqScsiPhyDrvServiceHours oid: 1.3.6.1.4.1.232.5.2.4.1.1.10 type: counter help: SCSI Physical Drive Service Time in hours - 1.3.6.1.4.1.232.5.2.4.1.1.10 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHighReadSectors oid: 1.3.6.1.4.1.232.5.2.4.1.1.11 type: counter help: SCSI Physical Drive Sectors Read (high) - 1.3.6.1.4.1.232.5.2.4.1.1.11 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvLowReadSectors oid: 1.3.6.1.4.1.232.5.2.4.1.1.12 type: counter help: SCSI Physical Drive Sectors Read (low) - 1.3.6.1.4.1.232.5.2.4.1.1.12 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHighWriteSectors oid: 1.3.6.1.4.1.232.5.2.4.1.1.13 type: counter help: SCSI Physical Drive Sectors Written (high) - 1.3.6.1.4.1.232.5.2.4.1.1.13 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvLowWriteSectors oid: 1.3.6.1.4.1.232.5.2.4.1.1.14 type: counter help: SCSI Physical Drive Sectors Written (low) - 1.3.6.1.4.1.232.5.2.4.1.1.14 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHardReadErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.15 type: counter help: SCSI Physical Drive Hard Read Errors - 1.3.6.1.4.1.232.5.2.4.1.1.15 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHardWriteErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.16 type: counter help: SCSI Physical Drive Hard Write Errors - 1.3.6.1.4.1.232.5.2.4.1.1.16 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvEccCorrReads oid: 1.3.6.1.4.1.232.5.2.4.1.1.17 type: counter help: SCSI Physical Drive ECC Corrected Read Errors (high) - 1.3.6.1.4.1.232.5.2.4.1.1.17 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvRecvReadErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.18 type: counter help: SCSI Physical Drive Recovered Read Errors - 1.3.6.1.4.1.232.5.2.4.1.1.18 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvRecvWriteErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.19 type: counter help: SCSI Physical Drive Recovered Write Errors - 1.3.6.1.4.1.232.5.2.4.1.1.19 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvSeekErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.20 type: counter help: SCSI Physical Drive Seek Errors - 1.3.6.1.4.1.232.5.2.4.1.1.20 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvSpinupTime oid: 1.3.6.1.4.1.232.5.2.4.1.1.21 type: gauge help: SCSI Physical Drive Spin up Time (tenths of seconds) - 1.3.6.1.4.1.232.5.2.4.1.1.21 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvUsedReallocs oid: 1.3.6.1.4.1.232.5.2.4.1.1.22 type: counter help: SCSI Physical Drive Used Reallocation Sectors - 1.3.6.1.4.1.232.5.2.4.1.1.22 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvTimeouts oid: 1.3.6.1.4.1.232.5.2.4.1.1.23 type: counter help: SCSI Physical Drive Time-out Errors - 1.3.6.1.4.1.232.5.2.4.1.1.23 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvPostErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.24 type: counter help: SCSI Physical Drive Power On Self Test (POST) Errors - 1.3.6.1.4.1.232.5.2.4.1.1.24 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvPostErrCode oid: 1.3.6.1.4.1.232.5.2.4.1.1.25 type: gauge help: SCSI Physical Drive Last POST Error Code - 1.3.6.1.4.1.232.5.2.4.1.1.25 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvCondition oid: 1.3.6.1.4.1.232.5.2.4.1.1.26 type: gauge help: SCSI Physical Drive Condition - 1.3.6.1.4.1.232.5.2.4.1.1.26 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqScsiPhyDrvFuncTest1 oid: 1.3.6.1.4.1.232.5.2.4.1.1.27 type: gauge help: SCSI Physical Drive Functional Test 1 - 1.3.6.1.4.1.232.5.2.4.1.1.27 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvFuncTest2 oid: 1.3.6.1.4.1.232.5.2.4.1.1.28 type: gauge help: SCSI Physical Drive Functional Test 2 - 1.3.6.1.4.1.232.5.2.4.1.1.28 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvStatsPreserved oid: 1.3.6.1.4.1.232.5.2.4.1.1.29 type: gauge help: SCSI Physical Drive Statistics Preservation Method - 1.3.6.1.4.1.232.5.2.4.1.1.29 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: inNVRAM 3: onDisk 4: noCPUSupport 5: noFreeNVRAM 6: noDrvSupport 7: noSoftwareSupport 8: statsNotSupported - name: cpqScsiPhyDrvSerialNum oid: 1.3.6.1.4.1.232.5.2.4.1.1.30 type: DisplayString help: SCSI Physical Drive Serial Number - 1.3.6.1.4.1.232.5.2.4.1.1.30 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvLocation oid: 1.3.6.1.4.1.232.5.2.4.1.1.31 type: gauge help: SCSI Physical Drive Location - 1.3.6.1.4.1.232.5.2.4.1.1.31 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: proliant - name: cpqScsiPhyDrvParent oid: 1.3.6.1.4.1.232.5.2.4.1.1.32 type: gauge help: SCSI Physical Drive Parent - 1.3.6.1.4.1.232.5.2.4.1.1.32 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvSectorSize oid: 1.3.6.1.4.1.232.5.2.4.1.1.33 type: gauge help: SCSI Physical Drive Sector Size in Bytes - 1.3.6.1.4.1.232.5.2.4.1.1.33 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHotPlug oid: 1.3.6.1.4.1.232.5.2.4.1.1.34 type: gauge help: SCSI Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.2.4.1.1.34 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: hotPlug 3: nonHotPlug - name: cpqScsiPhyDrvPlacement oid: 1.3.6.1.4.1.232.5.2.4.1.1.35 type: gauge help: SCSI Physical Drive Placement - 1.3.6.1.4.1.232.5.2.4.1.1.35 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: internal 3: external - name: cpqScsiPhyDrvPreFailMonitoring oid: 1.3.6.1.4.1.232.5.2.4.1.1.36 type: gauge help: SCSI Physical Drive Predictive Failure Monitoring - 1.3.6.1.4.1.232.5.2.4.1.1.36 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: notAvailable 3: available - name: cpqScsiPhyDrvOsName oid: 1.3.6.1.4.1.232.5.2.4.1.1.37 type: DisplayString help: Physical Drive OS Name - 1.3.6.1.4.1.232.5.2.4.1.1.37 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvRotationalSpeed oid: 1.3.6.1.4.1.232.5.2.4.1.1.38 type: gauge help: SCSI Physical Drive Rotational Speed - 1.3.6.1.4.1.232.5.2.4.1.1.38 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: rpm7200 3: rpm10K 4: rpm15K - name: cpqScsiPhyDrvMemberLogDrv oid: 1.3.6.1.4.1.232.5.2.4.1.1.39 type: gauge help: The Physical Drive is a Member of a Logical Drive - 1.3.6.1.4.1.232.5.2.4.1.1.39 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: member 3: spare 4: nonMember - name: cpqScsiTargetCntlrIndex oid: 1.3.6.1.4.1.232.5.2.5.1.1.1 type: gauge help: SCSI Target Controller Index - 1.3.6.1.4.1.232.5.2.5.1.1.1 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetBusIndex oid: 1.3.6.1.4.1.232.5.2.5.1.1.2 type: gauge help: SCSI Target Bus Index - 1.3.6.1.4.1.232.5.2.5.1.1.2 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetScsiIdIndex oid: 1.3.6.1.4.1.232.5.2.5.1.1.3 type: gauge help: SCSI Target Device Index - 1.3.6.1.4.1.232.5.2.5.1.1.3 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetType oid: 1.3.6.1.4.1.232.5.2.5.1.1.4 type: gauge help: SCSI Device Type - 1.3.6.1.4.1.232.5.2.5.1.1.4 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: disk 3: tape 4: printer 5: processor 6: wormDrive 7: cd-rom 8: scanner 9: optical 10: jukeBox 11: commDev - name: cpqScsiTargetModel oid: 1.3.6.1.4.1.232.5.2.5.1.1.5 type: DisplayString help: SCSI Device Model - 1.3.6.1.4.1.232.5.2.5.1.1.5 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetFWRev oid: 1.3.6.1.4.1.232.5.2.5.1.1.6 type: DisplayString help: SCSI Device Firmware Revision - 1.3.6.1.4.1.232.5.2.5.1.1.6 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetVendor oid: 1.3.6.1.4.1.232.5.2.5.1.1.7 type: DisplayString help: SCSI Device Vendor - 1.3.6.1.4.1.232.5.2.5.1.1.7 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetParityErrs oid: 1.3.6.1.4.1.232.5.2.5.1.1.8 type: counter help: SCSI Device Bus Parity Errors - 1.3.6.1.4.1.232.5.2.5.1.1.8 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetPhaseErrs oid: 1.3.6.1.4.1.232.5.2.5.1.1.9 type: counter help: SCSI Device Bus Phase Errors - 1.3.6.1.4.1.232.5.2.5.1.1.9 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetSelectTimeouts oid: 1.3.6.1.4.1.232.5.2.5.1.1.10 type: counter help: SCSI Device Bus Select Time-outs - 1.3.6.1.4.1.232.5.2.5.1.1.10 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetMsgRejects oid: 1.3.6.1.4.1.232.5.2.5.1.1.11 type: counter help: SCSI Device Bus Message Rejects - 1.3.6.1.4.1.232.5.2.5.1.1.11 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetNegPeriod oid: 1.3.6.1.4.1.232.5.2.5.1.1.12 type: gauge help: SCSI Device Negotiated Period - 1.3.6.1.4.1.232.5.2.5.1.1.12 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetLocation oid: 1.3.6.1.4.1.232.5.2.5.1.1.13 type: gauge help: SCSI Device Location - 1.3.6.1.4.1.232.5.2.5.1.1.13 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: proliant - name: cpqScsiTargetNegSpeed oid: 1.3.6.1.4.1.232.5.2.5.1.1.14 type: gauge help: SCSI Device Negotiated Speed - 1.3.6.1.4.1.232.5.2.5.1.1.14 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetPhysWidth oid: 1.3.6.1.4.1.232.5.2.5.1.1.15 type: gauge help: SCSI Device Data Bus Physical Width - 1.3.6.1.4.1.232.5.2.5.1.1.15 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: narrow 3: wide16 - name: cpqScsiTargetNegWidth oid: 1.3.6.1.4.1.232.5.2.5.1.1.16 type: gauge help: SCSI Device Data Bus Negotiated Width - 1.3.6.1.4.1.232.5.2.5.1.1.16 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetTypeExtended oid: 1.3.6.1.4.1.232.5.2.5.1.1.17 type: gauge help: SCSI Extended Device Type - 1.3.6.1.4.1.232.5.2.5.1.1.17 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: pdcd 3: removableDisk 4: dltAutoloader 5: cdJukebox 6: cr3500 7: autoloader - name: cpqScsiTargetCurrentSpeed oid: 1.3.6.1.4.1.232.5.2.5.1.1.18 type: gauge help: SCSI Device Current Data Transfer Speed - 1.3.6.1.4.1.232.5.2.5.1.1.18 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: asynchronous 3: fast 4: ultra 5: ultra2 6: ultra3 7: scsi1 8: ultra4 - name: cpqScsiCdDrvCntlrIndex oid: 1.3.6.1.4.1.232.5.2.6.1.1.1 type: gauge help: SCSI CD-ROM Drive Controller Index - 1.3.6.1.4.1.232.5.2.6.1.1.1 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvBusIndex oid: 1.3.6.1.4.1.232.5.2.6.1.1.2 type: gauge help: SCSI CD-ROM Drive Bus Index - 1.3.6.1.4.1.232.5.2.6.1.1.2 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvScsiIdIndex oid: 1.3.6.1.4.1.232.5.2.6.1.1.3 type: gauge help: SCSI CD-ROM Drive Index - 1.3.6.1.4.1.232.5.2.6.1.1.3 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvLunIndex oid: 1.3.6.1.4.1.232.5.2.6.1.1.4 type: gauge help: SCSI CD-ROM Drive Logical Unit Index - 1.3.6.1.4.1.232.5.2.6.1.1.4 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvModel oid: 1.3.6.1.4.1.232.5.2.6.1.1.5 type: DisplayString help: SCSI CD Device Model - 1.3.6.1.4.1.232.5.2.6.1.1.5 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvVendor oid: 1.3.6.1.4.1.232.5.2.6.1.1.6 type: DisplayString help: SCSI CD Drive Vendor - 1.3.6.1.4.1.232.5.2.6.1.1.6 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvFwRev oid: 1.3.6.1.4.1.232.5.2.6.1.1.7 type: DisplayString help: SCSI CD-ROM Firmware Revision - 1.3.6.1.4.1.232.5.2.6.1.1.7 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqCdLibraryCntlrIndex oid: 1.3.6.1.4.1.232.5.2.6.2.1.1 type: gauge help: SCSI CD Library Controller Index - 1.3.6.1.4.1.232.5.2.6.2.1.1 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryBusIndex oid: 1.3.6.1.4.1.232.5.2.6.2.1.2 type: gauge help: SCSI CD Library Bus Index - 1.3.6.1.4.1.232.5.2.6.2.1.2 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryScsiIdIndex oid: 1.3.6.1.4.1.232.5.2.6.2.1.3 type: gauge help: SCSI CD Library Device Index - 1.3.6.1.4.1.232.5.2.6.2.1.3 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryLunIndex oid: 1.3.6.1.4.1.232.5.2.6.2.1.4 type: gauge help: SCSI CD Library Logical Unit Index - 1.3.6.1.4.1.232.5.2.6.2.1.4 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryCondition oid: 1.3.6.1.4.1.232.5.2.6.2.1.5 type: gauge help: CD Library Condition - 1.3.6.1.4.1.232.5.2.6.2.1.5 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqCdLibraryStatus oid: 1.3.6.1.4.1.232.5.2.6.2.1.6 type: gauge help: CD Library Status - 1.3.6.1.4.1.232.5.2.6.2.1.6 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: offline - name: cpqCdLibraryModel oid: 1.3.6.1.4.1.232.5.2.6.2.1.7 type: DisplayString help: SCSI CD Library Device Model - 1.3.6.1.4.1.232.5.2.6.2.1.7 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryVendor oid: 1.3.6.1.4.1.232.5.2.6.2.1.8 type: DisplayString help: SCSI CD Library Vendor - 1.3.6.1.4.1.232.5.2.6.2.1.8 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibrarySerialNumber oid: 1.3.6.1.4.1.232.5.2.6.2.1.9 type: DisplayString help: CD Library Serial Number - 1.3.6.1.4.1.232.5.2.6.2.1.9 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryDriveList oid: 1.3.6.1.4.1.232.5.2.6.2.1.10 type: OctetString help: CD Library Drive List This is a data structure containing the list of CD drive ids that are present in this library - 1.3.6.1.4.1.232.5.2.6.2.1.10 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryFwRev oid: 1.3.6.1.4.1.232.5.2.6.2.1.11 type: DisplayString help: SCSI CD Library Firmware Revision - 1.3.6.1.4.1.232.5.2.6.2.1.11 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryFwSubtype oid: 1.3.6.1.4.1.232.5.2.6.2.1.12 type: gauge help: SCSI CD library Firmware Subtype - 1.3.6.1.4.1.232.5.2.6.2.1.12 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqScsiTrapPkts oid: 1.3.6.1.4.1.232.5.3.1 type: counter help: The total number of trap packets issued by the SCSI enterprise since the instrument agent was loaded. - 1.3.6.1.4.1.232.5.3.1 - name: cpqScsiTrapLogMaxSize oid: 1.3.6.1.4.1.232.5.3.2 type: gauge help: The maximum number of entries that will currently be kept in the trap log - 1.3.6.1.4.1.232.5.3.2 - name: cpqScsiTrapLogIndex oid: 1.3.6.1.4.1.232.5.3.3.1.1 type: gauge help: The value of this object uniquely identifies this trapLogEntry at this time - 1.3.6.1.4.1.232.5.3.3.1.1 indexes: - labelname: cpqScsiTrapLogIndex type: gauge - name: cpqScsiTrapType oid: 1.3.6.1.4.1.232.5.3.3.1.2 type: gauge help: The type of the trap event that this entry describes - 1.3.6.1.4.1.232.5.3.3.1.2 indexes: - labelname: cpqScsiTrapLogIndex type: gauge enum_values: 1: cpqScsiCntlrStatusChange 2: cpqScsiLogDrvStatusChange 3: cpqScsiPhyDrvStatusChange 5001: cpqScsi2CntlrStatusChange 5002: cpqScsi2LogDrvStatusChange 5003: cpqScsi2PhyDrvStatusChange - name: cpqScsiTrapTime oid: 1.3.6.1.4.1.232.5.3.3.1.3 type: OctetString help: The time of the trap event that this entry describes - 1.3.6.1.4.1.232.5.3.3.1.3 indexes: - labelname: cpqScsiTrapLogIndex type: gauge - name: cpqTapePhyDrvCntlrIndex oid: 1.3.6.1.4.1.232.5.4.1.1.1.1 type: gauge help: Tape Physical Drive Controller Index - 1.3.6.1.4.1.232.5.4.1.1.1.1 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvBusIndex oid: 1.3.6.1.4.1.232.5.4.1.1.1.2 type: gauge help: Tape Physical Drive Bus Index - 1.3.6.1.4.1.232.5.4.1.1.1.2 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvScsiIdIndex oid: 1.3.6.1.4.1.232.5.4.1.1.1.3 type: gauge help: Tape Physical Drive Index - 1.3.6.1.4.1.232.5.4.1.1.1.3 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvLunIndex oid: 1.3.6.1.4.1.232.5.4.1.1.1.4 type: gauge help: Tape Physical Drive Logical Unit Index - 1.3.6.1.4.1.232.5.4.1.1.1.4 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvType oid: 1.3.6.1.4.1.232.5.4.1.1.1.5 type: gauge help: Tape Device Type - 1.3.6.1.4.1.232.5.4.1.1.1.5 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: cpqDat4-16 3: cpqDatAuto 4: cpqDat2-8 5: cpqDlt10-20 6: cpqDlt20-40 7: cpqDlt15-30 8: cpqDlt35-70 9: cpqDat4-8 10: cpqSlr4-8 11: cpqDat12-24 12: cpqDatAuto12-24 13: cpqMlr16-32 14: cpqAit35 15: cpqAit50 16: cpqDat20-40 17: cpqDlt40-80 18: cpqDatAuto20-40 19: cpqSuperDlt1 20: cpqAit35Lvd 21: cpqCompaq - name: cpqTapePhyDrvCondition oid: 1.3.6.1.4.1.232.5.4.1.1.1.6 type: gauge help: Tape Physical Drive Status - 1.3.6.1.4.1.232.5.4.1.1.1.6 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqTapePhyDrvMagSize oid: 1.3.6.1.4.1.232.5.4.1.1.1.7 type: gauge help: Tape Physical Drive Magazine Size - 1.3.6.1.4.1.232.5.4.1.1.1.7 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvSerialNumber oid: 1.3.6.1.4.1.232.5.4.1.1.1.8 type: DisplayString help: Tape Physical Drive Serial Number - 1.3.6.1.4.1.232.5.4.1.1.1.8 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvCleanReq oid: 1.3.6.1.4.1.232.5.4.1.1.1.9 type: gauge help: Tape Physical Drive Cleaning Required Status - 1.3.6.1.4.1.232.5.4.1.1.1.9 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqTapePhyDrvCleanTapeRepl oid: 1.3.6.1.4.1.232.5.4.1.1.1.10 type: gauge help: Tape Physical Drive Cleaning Tape Replacement Status - 1.3.6.1.4.1.232.5.4.1.1.1.10 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqTapePhyDrvFwSubtype oid: 1.3.6.1.4.1.232.5.4.1.1.1.11 type: gauge help: Tape Physical Drive Firmware Subtype - 1.3.6.1.4.1.232.5.4.1.1.1.11 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvName oid: 1.3.6.1.4.1.232.5.4.1.1.1.12 type: DisplayString help: Tape Physical Drive Name - 1.3.6.1.4.1.232.5.4.1.1.1.12 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvCleanTapeCount oid: 1.3.6.1.4.1.232.5.4.1.1.1.13 type: gauge help: Tape Physical Drive Cleaning Tape Count - 1.3.6.1.4.1.232.5.4.1.1.1.13 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvFwRev oid: 1.3.6.1.4.1.232.5.4.1.1.1.14 type: DisplayString help: Tape Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.4.1.1.1.14 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvStatus oid: 1.3.6.1.4.1.232.5.4.1.1.1.15 type: gauge help: Tape Physical Drive Status - 1.3.6.1.4.1.232.5.4.1.1.1.15 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: ok 4: failed 5: offline 6: missingWasOk 7: missingWasFailed 8: missingWasOffline - name: cpqTapePhyDrvHotPlug oid: 1.3.6.1.4.1.232.5.4.1.1.1.16 type: gauge help: Tape Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.4.1.1.1.16 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: hotPlug 3: nonHotPlug - name: cpqTapePhyDrvPlacement oid: 1.3.6.1.4.1.232.5.4.1.1.1.17 type: gauge help: Tape Physical Drive Placement - 1.3.6.1.4.1.232.5.4.1.1.1.17 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: internal 3: external - name: cpqTapePhyDrvLibraryDrive oid: 1.3.6.1.4.1.232.5.4.1.1.1.18 type: gauge help: Tape Physical Drive Library Drive - 1.3.6.1.4.1.232.5.4.1.1.1.18 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqTapePhyDrvLoaderName oid: 1.3.6.1.4.1.232.5.4.1.1.1.19 type: DisplayString help: Tape Autoloader Name - 1.3.6.1.4.1.232.5.4.1.1.1.19 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvLoaderFwRev oid: 1.3.6.1.4.1.232.5.4.1.1.1.20 type: DisplayString help: Tape Autoloader Firmware Revision - 1.3.6.1.4.1.232.5.4.1.1.1.20 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvLoaderSerialNum oid: 1.3.6.1.4.1.232.5.4.1.1.1.21 type: DisplayString help: Tape Autoloader Serial Number - 1.3.6.1.4.1.232.5.4.1.1.1.21 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapeCountersCntlrIndex oid: 1.3.6.1.4.1.232.5.4.2.1.1.1 type: gauge help: SCSI Counters Controller Index - 1.3.6.1.4.1.232.5.4.2.1.1.1 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersBusIndex oid: 1.3.6.1.4.1.232.5.4.2.1.1.2 type: gauge help: SCSI Counters Bus Index - 1.3.6.1.4.1.232.5.4.2.1.1.2 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersScsiIdIndex oid: 1.3.6.1.4.1.232.5.4.2.1.1.3 type: gauge help: SCSI Counters Device Index - 1.3.6.1.4.1.232.5.4.2.1.1.3 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersLunIndex oid: 1.3.6.1.4.1.232.5.4.2.1.1.4 type: gauge help: SCSI Counters Logical Unit Index - 1.3.6.1.4.1.232.5.4.2.1.1.4 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersReWrites oid: 1.3.6.1.4.1.232.5.4.2.1.1.5 type: counter help: Tape Device Re-write count - 1.3.6.1.4.1.232.5.4.2.1.1.5 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersReReads oid: 1.3.6.1.4.1.232.5.4.2.1.1.6 type: counter help: Tape Device Re-read count - 1.3.6.1.4.1.232.5.4.2.1.1.6 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersTotalErrors oid: 1.3.6.1.4.1.232.5.4.2.1.1.7 type: counter help: Tape Device Total Errors - 1.3.6.1.4.1.232.5.4.2.1.1.7 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersTotalUncorrectable oid: 1.3.6.1.4.1.232.5.4.2.1.1.8 type: counter help: Tape Device Total Uncorrectable Errors - 1.3.6.1.4.1.232.5.4.2.1.1.8 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersTotalBytes oid: 1.3.6.1.4.1.232.5.4.2.1.1.9 type: counter help: Tape Device Total Bytes - 1.3.6.1.4.1.232.5.4.2.1.1.9 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeLibraryCntlrIndex oid: 1.3.6.1.4.1.232.5.4.3.1.1.1 type: gauge help: SCSI Library Controller Index - 1.3.6.1.4.1.232.5.4.3.1.1.1 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryBusIndex oid: 1.3.6.1.4.1.232.5.4.3.1.1.2 type: gauge help: SCSI Library Bus Index - 1.3.6.1.4.1.232.5.4.3.1.1.2 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryScsiIdIndex oid: 1.3.6.1.4.1.232.5.4.3.1.1.3 type: gauge help: SCSI Library Device Index - 1.3.6.1.4.1.232.5.4.3.1.1.3 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryLunIndex oid: 1.3.6.1.4.1.232.5.4.3.1.1.4 type: gauge help: SCSI Library Logical Unit Index - 1.3.6.1.4.1.232.5.4.3.1.1.4 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryCondition oid: 1.3.6.1.4.1.232.5.4.3.1.1.5 type: gauge help: Tape Library Status - 1.3.6.1.4.1.232.5.4.3.1.1.5 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqTapeLibraryStatus oid: 1.3.6.1.4.1.232.5.4.3.1.1.6 type: gauge help: Error code returned by the last library error. - 1.3.6.1.4.1.232.5.4.3.1.1.6 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryDoorStatus oid: 1.3.6.1.4.1.232.5.4.3.1.1.7 type: gauge help: Status of the library door - 1.3.6.1.4.1.232.5.4.3.1.1.7 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: closed 3: open 4: notSupported - name: cpqTapeLibraryStatHours oid: 1.3.6.1.4.1.232.5.4.3.1.1.8 type: counter help: The number of hours of operation for the library. - 1.3.6.1.4.1.232.5.4.3.1.1.8 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryStatMoves oid: 1.3.6.1.4.1.232.5.4.3.1.1.9 type: counter help: The number of tape moves for the library loader arm. - 1.3.6.1.4.1.232.5.4.3.1.1.9 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryName oid: 1.3.6.1.4.1.232.5.4.3.1.1.10 type: DisplayString help: Tape Library Name. - 1.3.6.1.4.1.232.5.4.3.1.1.10 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibrarySerialNumber oid: 1.3.6.1.4.1.232.5.4.3.1.1.11 type: DisplayString help: Tape Library Serial Number - 1.3.6.1.4.1.232.5.4.3.1.1.11 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryDriveList oid: 1.3.6.1.4.1.232.5.4.3.1.1.12 type: OctetString help: Tape Library Drive List This is a data structure containing the list of tape drive ids that are present in this library - 1.3.6.1.4.1.232.5.4.3.1.1.12 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryState oid: 1.3.6.1.4.1.232.5.4.3.1.1.13 type: gauge help: Tape Library Status - 1.3.6.1.4.1.232.5.4.3.1.1.13 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed 5: offline - name: cpqTapeLibraryTemperature oid: 1.3.6.1.4.1.232.5.4.3.1.1.14 type: gauge help: Tape Library Temperature Status - 1.3.6.1.4.1.232.5.4.3.1.1.14 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: notSupported 3: ok 4: safeTempExceeded 5: maxTempExceeded - name: cpqTapeLibraryRedundancy oid: 1.3.6.1.4.1.232.5.4.3.1.1.15 type: gauge help: Tape Library Redundancy Status - 1.3.6.1.4.1.232.5.4.3.1.1.15 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: notSupported 3: capable 4: notCapable 5: active - name: cpqTapeLibraryHotSwap oid: 1.3.6.1.4.1.232.5.4.3.1.1.16 type: gauge help: Tape Library Hot Swap Status - 1.3.6.1.4.1.232.5.4.3.1.1.16 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: notSupported 3: capable 4: notCapable - name: cpqTapeLibraryFwRev oid: 1.3.6.1.4.1.232.5.4.3.1.1.17 type: DisplayString help: Tape Library Firmware Revision - 1.3.6.1.4.1.232.5.4.3.1.1.17 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryTapeList oid: 1.3.6.1.4.1.232.5.4.3.1.1.18 type: OctetString help: Tape Library Drive List This is a data structure containing the list of tape drive ids that are present in this library - 1.3.6.1.4.1.232.5.4.3.1.1.18 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqSasHbaIndex oid: 1.3.6.1.4.1.232.5.5.1.1.1.1 type: gauge help: SAS Host Bus Adapter Index - 1.3.6.1.4.1.232.5.5.1.1.1.1 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaHwLocation oid: 1.3.6.1.4.1.232.5.5.1.1.1.2 type: DisplayString help: SAS Host Bus Adapter Hardware Location - 1.3.6.1.4.1.232.5.5.1.1.1.2 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaModel oid: 1.3.6.1.4.1.232.5.5.1.1.1.3 type: gauge help: SAS Host Bus Adapter Model - 1.3.6.1.4.1.232.5.5.1.1.1.3 indexes: - labelname: cpqSasHbaIndex type: gauge enum_values: 1: other 2: generic 3: sas8int 4: sas4int 5: sasSc44Ge 6: sasSc40Ge 7: sasSc08Ge 8: sasSc08e 9: sasH220i 10: sasH221 11: sasH210i 12: sasH220 13: sasH222 14: sasP824ip - name: cpqSasHbaStatus oid: 1.3.6.1.4.1.232.5.5.1.1.1.4 type: gauge help: SAS Host Bus Adapter Status - 1.3.6.1.4.1.232.5.5.1.1.1.4 indexes: - labelname: cpqSasHbaIndex type: gauge enum_values: 1: other 2: ok 3: failed - name: cpqSasHbaCondition oid: 1.3.6.1.4.1.232.5.5.1.1.1.5 type: gauge help: SAS Host Bus Adapter Condition - 1.3.6.1.4.1.232.5.5.1.1.1.5 indexes: - labelname: cpqSasHbaIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasHbaOverallCondition oid: 1.3.6.1.4.1.232.5.5.1.1.1.6 type: gauge help: SAS Host Bus Adapter Overall Condition - 1.3.6.1.4.1.232.5.5.1.1.1.6 indexes: - labelname: cpqSasHbaIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasHbaSerialNumber oid: 1.3.6.1.4.1.232.5.5.1.1.1.7 type: DisplayString help: SAS Host Bus Adapter Serial Number - 1.3.6.1.4.1.232.5.5.1.1.1.7 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaFwVersion oid: 1.3.6.1.4.1.232.5.5.1.1.1.8 type: DisplayString help: SAS Host Bus Adapter Firmware Version - 1.3.6.1.4.1.232.5.5.1.1.1.8 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaBiosVersion oid: 1.3.6.1.4.1.232.5.5.1.1.1.9 type: DisplayString help: SAS Host Bus Adapter BIOS Version - 1.3.6.1.4.1.232.5.5.1.1.1.9 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaPciLocation oid: 1.3.6.1.4.1.232.5.5.1.1.1.10 type: DisplayString help: SAS Host Bus Adapter PCI Location - 1.3.6.1.4.1.232.5.5.1.1.1.10 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasPhyDrvHbaIndex oid: 1.3.6.1.4.1.232.5.5.2.1.1.1 type: gauge help: SAS Physical Drive HBA Index - 1.3.6.1.4.1.232.5.5.2.1.1.1 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvIndex oid: 1.3.6.1.4.1.232.5.5.2.1.1.2 type: gauge help: SAS Physical Drive Index - 1.3.6.1.4.1.232.5.5.2.1.1.2 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvLocationString oid: 1.3.6.1.4.1.232.5.5.2.1.1.3 type: DisplayString help: SAS Physical Drive Location String - 1.3.6.1.4.1.232.5.5.2.1.1.3 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvModel oid: 1.3.6.1.4.1.232.5.5.2.1.1.4 type: DisplayString help: SAS Physical Drive Model - 1.3.6.1.4.1.232.5.5.2.1.1.4 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvStatus oid: 1.3.6.1.4.1.232.5.5.2.1.1.5 type: gauge help: SAS Physical Drive Status - 1.3.6.1.4.1.232.5.5.2.1.1.5 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: predictiveFailure 4: offline 5: failed 6: missingWasOk 7: missingWasPredictiveFailure 8: missingWasOffline 9: missingWasFailed 10: ssdWearOut 11: missingWasSSDWearOut 12: notAuthenticated 13: missingWasNotAuthenticated - name: cpqSasPhyDrvCondition oid: 1.3.6.1.4.1.232.5.5.2.1.1.6 type: gauge help: SAS Physical Drive Condition - 1.3.6.1.4.1.232.5.5.2.1.1.6 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasPhyDrvFWRev oid: 1.3.6.1.4.1.232.5.5.2.1.1.7 type: DisplayString help: SAS Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.7 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSize oid: 1.3.6.1.4.1.232.5.5.2.1.1.8 type: gauge help: SAS Physical Drive Size in MB - 1.3.6.1.4.1.232.5.5.2.1.1.8 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvUsedReallocs oid: 1.3.6.1.4.1.232.5.5.2.1.1.9 type: counter help: SAS Physical Drive Used Reallocation Sectors - 1.3.6.1.4.1.232.5.5.2.1.1.9 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSerialNumber oid: 1.3.6.1.4.1.232.5.5.2.1.1.10 type: DisplayString help: SAS Physical Drive Serial Number - 1.3.6.1.4.1.232.5.5.2.1.1.10 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvMemberLogDrv oid: 1.3.6.1.4.1.232.5.5.2.1.1.11 type: gauge help: The Physical Drive is a Member of a Logical Drive - 1.3.6.1.4.1.232.5.5.2.1.1.11 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: member 3: spare 4: nonMember - name: cpqSasPhyDrvRotationalSpeed oid: 1.3.6.1.4.1.232.5.5.2.1.1.12 type: gauge help: SAS Physical Drive Rotational Speed - 1.3.6.1.4.1.232.5.5.2.1.1.12 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: rpm7200 3: rpm10K 4: rpm15K 5: rpmSsd - name: cpqSasPhyDrvOsName oid: 1.3.6.1.4.1.232.5.5.2.1.1.13 type: DisplayString help: SAS Physical Drive OS Name - 1.3.6.1.4.1.232.5.5.2.1.1.13 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvPlacement oid: 1.3.6.1.4.1.232.5.5.2.1.1.14 type: gauge help: SAS Physical Drive Placement - 1.3.6.1.4.1.232.5.5.2.1.1.14 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: internal 3: external - name: cpqSasPhyDrvHotPlug oid: 1.3.6.1.4.1.232.5.5.2.1.1.15 type: gauge help: SAS Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.5.2.1.1.15 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: hotPlug 3: nonHotPlug - name: cpqSasPhyDrvType oid: 1.3.6.1.4.1.232.5.5.2.1.1.16 type: gauge help: SAS Physical Drive Type - 1.3.6.1.4.1.232.5.5.2.1.1.16 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: sas 3: sata - name: cpqSasPhyDrvSasAddress oid: 1.3.6.1.4.1.232.5.5.2.1.1.17 type: DisplayString help: SAS Physical Drive SAS Address - 1.3.6.1.4.1.232.5.5.2.1.1.17 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvMediaType oid: 1.3.6.1.4.1.232.5.5.2.1.1.18 type: gauge help: SAS Physical Drive Media Type - 1.3.6.1.4.1.232.5.5.2.1.1.18 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: rotatingPlatters 3: solidState - name: cpqSasPhyDrvSSDWearStatus oid: 1.3.6.1.4.1.232.5.5.2.1.1.19 type: gauge help: SAS Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.5.5.2.1.1.19 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: fiftySixDayThreshold 4: fivePercentThreshold 5: twoPercentThreshold 6: ssdWearOut - name: cpqSasPhyDrvPowerOnHours oid: 1.3.6.1.4.1.232.5.5.2.1.1.20 type: counter help: SAS Physical Drive Power On Hours - 1.3.6.1.4.1.232.5.5.2.1.1.20 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSSDPercntEndrnceUsed oid: 1.3.6.1.4.1.232.5.5.2.1.1.21 type: gauge help: SAS Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.5.5.2.1.1.21 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSSDEstTimeRemainingHours oid: 1.3.6.1.4.1.232.5.5.2.1.1.22 type: counter help: SAS Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.5.5.2.1.1.22 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvAuthenticationStatus oid: 1.3.6.1.4.1.232.5.5.2.1.1.23 type: gauge help: SAS Physical Drive Authentication Status - 1.3.6.1.4.1.232.5.5.2.1.1.23 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: notSupported 3: authenticationFailed 4: authenticationPassed - name: cpqSasPhyDrvSmartCarrierAppFWRev oid: 1.3.6.1.4.1.232.5.5.2.1.1.24 type: gauge help: SAS Physical Drive Smart Carrier Application Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.24 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSmartCarrierBootldrFWRev oid: 1.3.6.1.4.1.232.5.5.2.1.1.25 type: gauge help: SAS Physical Drive Smart Carrier Bootloader Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.25 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvCurrTemperature oid: 1.3.6.1.4.1.232.5.5.2.1.1.26 type: gauge help: SAS Physical Drive Current Operating Temperature degrees Celsius - 1.3.6.1.4.1.232.5.5.2.1.1.26 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvTemperatureThreshold oid: 1.3.6.1.4.1.232.5.5.2.1.1.27 type: gauge help: SAS Physical Drive Maximum Operating Temperature in degrees Celsius - 1.3.6.1.4.1.232.5.5.2.1.1.27 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSsBoxModel oid: 1.3.6.1.4.1.232.5.5.2.1.1.28 type: DisplayString help: SAS Physical Drive Box Model - 1.3.6.1.4.1.232.5.5.2.1.1.28 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSsBoxFwRev oid: 1.3.6.1.4.1.232.5.5.2.1.1.29 type: DisplayString help: SAS Physical Drive Box Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.29 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSsBoxVendor oid: 1.3.6.1.4.1.232.5.5.2.1.1.30 type: DisplayString help: SAS Physical Drive Box Vendor This is the SAS drive box`s vendor name - 1.3.6.1.4.1.232.5.5.2.1.1.30 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSsBoxSerialNumber oid: 1.3.6.1.4.1.232.5.5.2.1.1.31 type: DisplayString help: SAS Physical Drive Box Serial Number - 1.3.6.1.4.1.232.5.5.2.1.1.31 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasLogDrvHbaIndex oid: 1.3.6.1.4.1.232.5.5.3.1.1.1 type: gauge help: SAS Logical Drive HBA Index - 1.3.6.1.4.1.232.5.5.3.1.1.1 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvIndex oid: 1.3.6.1.4.1.232.5.5.3.1.1.2 type: gauge help: SAS Logical Drive Index - 1.3.6.1.4.1.232.5.5.3.1.1.2 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvRaidLevel oid: 1.3.6.1.4.1.232.5.5.3.1.1.3 type: gauge help: SAS Logical Drive RAID Level - 1.3.6.1.4.1.232.5.5.3.1.1.3 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge enum_values: 1: other 2: raid0 3: raid1 4: raid0plus1 5: raid5 6: raid15 7: volume - name: cpqSasLogDrvStatus oid: 1.3.6.1.4.1.232.5.5.3.1.1.4 type: gauge help: SAS Logical Drive Status - 1.3.6.1.4.1.232.5.5.3.1.1.4 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: rebuilding 5: failed 6: offline - name: cpqSasLogDrvCondition oid: 1.3.6.1.4.1.232.5.5.3.1.1.5 type: gauge help: SAS Logical Drive Condition - 1.3.6.1.4.1.232.5.5.3.1.1.5 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasLogDrvRebuildingDisk oid: 1.3.6.1.4.1.232.5.5.3.1.1.6 type: gauge help: SAS Logical Drive Rebuilding Disk - 1.3.6.1.4.1.232.5.5.3.1.1.6 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvCapacity oid: 1.3.6.1.4.1.232.5.5.3.1.1.7 type: gauge help: SAS Logical Drive Size - 1.3.6.1.4.1.232.5.5.3.1.1.7 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvStripeSize oid: 1.3.6.1.4.1.232.5.5.3.1.1.8 type: gauge help: SAS Logical Drive Stripe Size - 1.3.6.1.4.1.232.5.5.3.1.1.8 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvPhyDrvIds oid: 1.3.6.1.4.1.232.5.5.3.1.1.9 type: OctetString help: SAS Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.5.5.3.1.1.9 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvSpareIds oid: 1.3.6.1.4.1.232.5.5.3.1.1.10 type: OctetString help: SAS Logical Drive Spare Drive IDs - 1.3.6.1.4.1.232.5.5.3.1.1.10 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvOsName oid: 1.3.6.1.4.1.232.5.5.3.1.1.11 type: DisplayString help: SAS Logical Drive OS Name - 1.3.6.1.4.1.232.5.5.3.1.1.11 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvRebuildingPercent oid: 1.3.6.1.4.1.232.5.5.3.1.1.12 type: gauge help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.5.5.3.1.1.12 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasTapeDrvHbaIndex oid: 1.3.6.1.4.1.232.5.5.4.1.1.1 type: gauge help: SAS Tape Drive HBA Index - 1.3.6.1.4.1.232.5.5.4.1.1.1 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvIndex oid: 1.3.6.1.4.1.232.5.5.4.1.1.2 type: gauge help: SAS Tape Drive Index - 1.3.6.1.4.1.232.5.5.4.1.1.2 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvLocationString oid: 1.3.6.1.4.1.232.5.5.4.1.1.3 type: DisplayString help: SAS Tape Drive Location String - 1.3.6.1.4.1.232.5.5.4.1.1.3 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvName oid: 1.3.6.1.4.1.232.5.5.4.1.1.4 type: DisplayString help: SAS Tape Drive Name - 1.3.6.1.4.1.232.5.5.4.1.1.4 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvStatus oid: 1.3.6.1.4.1.232.5.5.4.1.1.5 type: gauge help: SAS Physical Drive Status - 1.3.6.1.4.1.232.5.5.4.1.1.5 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge enum_values: 1: other 2: ok 3: offline - name: cpqSasTapeDrvCondition oid: 1.3.6.1.4.1.232.5.5.4.1.1.6 type: gauge help: SAS Tape Drive Condition - 1.3.6.1.4.1.232.5.5.4.1.1.6 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasTapeDrvFWRev oid: 1.3.6.1.4.1.232.5.5.4.1.1.7 type: DisplayString help: SAS Tape Drive Firmware Revision - 1.3.6.1.4.1.232.5.5.4.1.1.7 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvSerialNumber oid: 1.3.6.1.4.1.232.5.5.4.1.1.8 type: DisplayString help: SAS Tape Drive Serial Number - 1.3.6.1.4.1.232.5.5.4.1.1.8 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvSasAddress oid: 1.3.6.1.4.1.232.5.5.4.1.1.9 type: DisplayString help: SAS Tape Drive SAS Address - 1.3.6.1.4.1.232.5.5.4.1.1.9 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqHeResMem2ModuleSize oid: 1.3.6.1.4.1.232.6.2.14.13.1.6 type: gauge help: Module memory size in kilobytes - 1.3.6.1.4.1.232.6.2.14.13.1.6 indexes: - labelname: cpqHeResMem2Module type: gauge - name: cpqHePowerMeterSupport oid: 1.3.6.1.4.1.232.6.2.15.1 type: gauge help: This value specifies whether Power Meter is supported by this Server - 1.3.6.1.4.1.232.6.2.15.1 enum_values: 1: other 2: supported 3: unsupported - name: cpqHePowerMeterStatus oid: 1.3.6.1.4.1.232.6.2.15.2 type: gauge help: This value specifies whether Power Meter reading is supported by this Server - 1.3.6.1.4.1.232.6.2.15.2 enum_values: 1: other 2: present 3: absent - name: cpqHePowerMeterCurrReading oid: 1.3.6.1.4.1.232.6.2.15.3 type: gauge help: This is the current Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.3 - name: cpqHePowerMeterPrevReading oid: 1.3.6.1.4.1.232.6.2.15.4 type: gauge help: This is the previous Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.4 - name: cpqHeHWBiosCondition oid: 1.3.6.1.4.1.232.6.2.16.1 type: gauge help: This value indicates an error has been detected during Pre-OS Test (POST) or during initial hardware initialization - 1.3.6.1.4.1.232.6.2.16.1 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeSysBackupBatteryCondition oid: 1.3.6.1.4.1.232.6.2.17.1 type: gauge help: This value specifies the overall condition of the battery backup sub-system. - 1.3.6.1.4.1.232.6.2.17.1 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeSysBatteryChassis oid: 1.3.6.1.4.1.232.6.2.17.2.1.1 type: gauge help: The system chassis number. - 1.3.6.1.4.1.232.6.2.17.2.1.1 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryIndex oid: 1.3.6.1.4.1.232.6.2.17.2.1.2 type: gauge help: The battery index number within this chassis. - 1.3.6.1.4.1.232.6.2.17.2.1.2 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryPresent oid: 1.3.6.1.4.1.232.6.2.17.2.1.3 type: gauge help: Indicates whether the backup battery is present in the chassis. - 1.3.6.1.4.1.232.6.2.17.2.1.3 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge enum_values: 1: other 2: absent 3: present - name: cpqHeSysBatteryCondition oid: 1.3.6.1.4.1.232.6.2.17.2.1.4 type: gauge help: The condition of the backup battery - 1.3.6.1.4.1.232.6.2.17.2.1.4 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeSysBatteryStatus oid: 1.3.6.1.4.1.232.6.2.17.2.1.5 type: gauge help: The status of the battery. - 1.3.6.1.4.1.232.6.2.17.2.1.5 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge enum_values: 1: noError 2: generalFailure 3: shutdownHighResistance 4: shutdownLowVoltage 5: shutdownShortCircuit 6: shutdownChargeTimeout 7: shutdownOverTemperature 8: shutdownDischargeMinVoltage 9: shutdownDischargeCurrent 10: shutdownLoadCountHigh 11: shutdownEnablePin 12: shutdownOverCurrent 13: shutdownPermanentFailure 14: shutdownBackupTimeExceeded 15: predictiveFailure - name: cpqHeSysBatteryCapacityMaximum oid: 1.3.6.1.4.1.232.6.2.17.2.1.6 type: gauge help: The maximum capacity of the battery in watts. - 1.3.6.1.4.1.232.6.2.17.2.1.6 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryProductName oid: 1.3.6.1.4.1.232.6.2.17.2.1.7 type: DisplayString help: The battery product name. - 1.3.6.1.4.1.232.6.2.17.2.1.7 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryModel oid: 1.3.6.1.4.1.232.6.2.17.2.1.8 type: DisplayString help: The battery model name. - 1.3.6.1.4.1.232.6.2.17.2.1.8 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatterySerialNumber oid: 1.3.6.1.4.1.232.6.2.17.2.1.9 type: DisplayString help: The battery serial number. - 1.3.6.1.4.1.232.6.2.17.2.1.9 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryFirmwareRev oid: 1.3.6.1.4.1.232.6.2.17.2.1.10 type: DisplayString help: The battery firmware revision - 1.3.6.1.4.1.232.6.2.17.2.1.10 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatterySparePartNum oid: 1.3.6.1.4.1.232.6.2.17.2.1.11 type: DisplayString help: The battery part number or spare part number. - 1.3.6.1.4.1.232.6.2.17.2.1.11 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeTemperatureChassis oid: 1.3.6.1.4.1.232.6.2.6.8.1.1 type: gauge help: The System Chassis number. - 1.3.6.1.4.1.232.6.2.6.8.1.1 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeTemperatureIndex oid: 1.3.6.1.4.1.232.6.2.6.8.1.2 type: gauge help: A number that uniquely specifies this temperature sensor description. - 1.3.6.1.4.1.232.6.2.6.8.1.2 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeTemperatureLocale oid: 1.3.6.1.4.1.232.6.2.6.8.1.3 type: EnumAsInfo help: This specifies the location of the temperature sensor present in the system. - 1.3.6.1.4.1.232.6.2.6.8.1.3 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge enum_values: 1: other 2: unknown 3: system 4: systemBoard 5: ioBoard 6: cpu 7: memory 8: storage 9: removableMedia 10: powerSupply 11: ambient 12: chassis 13: bridgeCard - name: cpqHeTemperatureCelsius oid: 1.3.6.1.4.1.232.6.2.6.8.1.4 type: gauge help: This is the current temperature sensor reading in degrees celsius - 1.3.6.1.4.1.232.6.2.6.8.1.4 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeTemperatureThreshold oid: 1.3.6.1.4.1.232.6.2.6.8.1.5 type: gauge help: This is the shutdown threshold temperature sensor setting in degrees celsius - 1.3.6.1.4.1.232.6.2.6.8.1.5 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeTemperatureCondition oid: 1.3.6.1.4.1.232.6.2.6.8.1.6 type: gauge help: The Temperature sensor condition - 1.3.6.1.4.1.232.6.2.6.8.1.6 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeTemperatureThresholdType oid: 1.3.6.1.4.1.232.6.2.6.8.1.7 type: gauge help: This specifies the type of this instance of temperature sensor - 1.3.6.1.4.1.232.6.2.6.8.1.7 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge enum_values: 1: other 5: blowout 9: caution 15: critical 16: noreaction - name: cpqHeTemperatureHwLocation oid: 1.3.6.1.4.1.232.6.2.6.8.1.8 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the temperature sensor - 1.3.6.1.4.1.232.6.2.6.8.1.8 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeFltTolPwrSupplyCondition oid: 1.3.6.1.4.1.232.6.2.9.1 type: gauge help: This value specifies the overall condition of the fault tolerant power supply sub-system. - 1.3.6.1.4.1.232.6.2.9.1 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeFltTolPwrSupplyStatus oid: 1.3.6.1.4.1.232.6.2.9.2 type: gauge help: This value specifies the status of the fault tolerant power supply. - 1.3.6.1.4.1.232.6.2.9.2 enum_values: 1: other 2: notSupported 3: notInstalled 4: installed - name: cpqHeFltTolPowerSupplyChassis oid: 1.3.6.1.4.1.232.6.2.9.3.1.1 type: gauge help: The system chassis number. - 1.3.6.1.4.1.232.6.2.9.3.1.1 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyBay oid: 1.3.6.1.4.1.232.6.2.9.3.1.2 type: gauge help: The bay number to index within this chassis. - 1.3.6.1.4.1.232.6.2.9.3.1.2 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyPresent oid: 1.3.6.1.4.1.232.6.2.9.3.1.3 type: gauge help: Indicates whether the power supply is present in the chassis. - 1.3.6.1.4.1.232.6.2.9.3.1.3 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: other 2: absent 3: present - name: cpqHeFltTolPowerSupplyCondition oid: 1.3.6.1.4.1.232.6.2.9.3.1.4 type: gauge help: The condition of the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.4 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeFltTolPowerSupplyStatus oid: 1.3.6.1.4.1.232.6.2.9.3.1.5 type: gauge help: The status of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.5 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: noError 2: generalFailure 3: bistFailure 4: fanFailure 5: tempFailure 6: interlockOpen 7: epromFailed 8: vrefFailed 9: dacFailed 10: ramTestFailed 11: voltageChannelFailed 12: orringdiodeFailed 13: brownOut 14: giveupOnStartup 15: nvramInvalid 16: calibrationTableInvalid 17: noPowerInput - name: cpqHeFltTolPowerSupplyMainVoltage oid: 1.3.6.1.4.1.232.6.2.9.3.1.6 type: gauge help: The input main voltage of the power supply in volts. - 1.3.6.1.4.1.232.6.2.9.3.1.6 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyCapacityUsed oid: 1.3.6.1.4.1.232.6.2.9.3.1.7 type: gauge help: The currently used capacity of the power supply in watts. - 1.3.6.1.4.1.232.6.2.9.3.1.7 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyCapacityMaximum oid: 1.3.6.1.4.1.232.6.2.9.3.1.8 type: gauge help: The maximum capacity of the power supply in watts. - 1.3.6.1.4.1.232.6.2.9.3.1.8 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyRedundant oid: 1.3.6.1.4.1.232.6.2.9.3.1.9 type: gauge help: The redundancy state of the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.9 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: other 2: notRedundant 3: redundant - name: cpqHeFltTolPowerSupplyModel oid: 1.3.6.1.4.1.232.6.2.9.3.1.10 type: DisplayString help: The power supply model name. - 1.3.6.1.4.1.232.6.2.9.3.1.10 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplySerialNumber oid: 1.3.6.1.4.1.232.6.2.9.3.1.11 type: DisplayString help: The power supply serial number. - 1.3.6.1.4.1.232.6.2.9.3.1.11 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyAutoRev oid: 1.3.6.1.4.1.232.6.2.9.3.1.12 type: OctetString help: The power supply auto revision number. - 1.3.6.1.4.1.232.6.2.9.3.1.12 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyHotPlug oid: 1.3.6.1.4.1.232.6.2.9.3.1.13 type: gauge help: This indicates if the power supply is capable of being removed and/or inserted while the system is in an operational state - 1.3.6.1.4.1.232.6.2.9.3.1.13 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: other 2: nonHotPluggable 3: hotPluggable - name: cpqHeFltTolPowerSupplyFirmwareRev oid: 1.3.6.1.4.1.232.6.2.9.3.1.14 type: DisplayString help: The power supply firmware revision - 1.3.6.1.4.1.232.6.2.9.3.1.14 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyHwLocation oid: 1.3.6.1.4.1.232.6.2.9.3.1.15 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.15 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplySparePartNum oid: 1.3.6.1.4.1.232.6.2.9.3.1.16 type: DisplayString help: The power supply part number or spare part number. - 1.3.6.1.4.1.232.6.2.9.3.1.16 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyRedundantPartner oid: 1.3.6.1.4.1.232.6.2.9.3.1.17 type: gauge help: This specifies the index of the redundant partner - 1.3.6.1.4.1.232.6.2.9.3.1.17 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyErrorCondition oid: 1.3.6.1.4.1.232.6.2.9.3.1.18 type: gauge help: The Error condition of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.18 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: noError 2: generalFailure 3: overvoltage 4: overcurrent 5: overtemperature 6: powerinputloss 7: fanfailure 8: vinhighwarning 9: vinlowwarning 10: vouthighwarning 11: voutlowwarning 12: inlettemphighwarning 13: iinternaltemphighwarning 14: vauxhighwarning 15: vauxlowwarning 16: powersupplymismatch 17: goodinstandby - name: cpqSm2CntlrRomDate oid: 1.3.6.1.4.1.232.9.2.2.1 type: DisplayString help: Remote Insight/ Integrated Lights-Out ROM Date - 1.3.6.1.4.1.232.9.2.2.1 - name: cpqSm2CntlrRomRevision oid: 1.3.6.1.4.1.232.9.2.2.2 type: DisplayString help: Remote Insight/ Integrated Lights-Out ROM Revision - 1.3.6.1.4.1.232.9.2.2.2 - name: cpqSm2CntlrVideoStatus oid: 1.3.6.1.4.1.232.9.2.2.3 type: gauge help: Remote Insight/ Integrated Lights-Out Video Hardware Status - 1.3.6.1.4.1.232.9.2.2.3 enum_values: 1: other 2: enabled 3: disabled - name: cpqSm2CntlrBatteryEnabled oid: 1.3.6.1.4.1.232.9.2.2.4 type: gauge help: Remote Insight Battery Enabled - 1.3.6.1.4.1.232.9.2.2.4 enum_values: 1: other 2: enabled 3: disabled 4: noBattery - name: cpqSm2CntlrBatteryStatus oid: 1.3.6.1.4.1.232.9.2.2.5 type: gauge help: Remote Insight Battery Status - 1.3.6.1.4.1.232.9.2.2.5 enum_values: 1: other 2: batteryOk 3: batteryFailed 4: batteryDisconnected - name: cpqSm2CntlrBatteryPercentCharged oid: 1.3.6.1.4.1.232.9.2.2.6 type: gauge help: Remote Insight Battery Percent Charged - 1.3.6.1.4.1.232.9.2.2.6 - name: cpqSm2CntlrAlertStatus oid: 1.3.6.1.4.1.232.9.2.2.7 type: gauge help: Remote Insight/ Integrated Lights-Out Alerting Status - 1.3.6.1.4.1.232.9.2.2.7 enum_values: 1: other 2: enabled 3: disabled - name: cpqSm2CntlrPendingAlerts oid: 1.3.6.1.4.1.232.9.2.2.8 type: gauge help: Pending Remote Insight/ Integrated Lights-Out alerts - 1.3.6.1.4.1.232.9.2.2.8 enum_values: 1: other 2: noAlertsPending 3: alertsPending 4: clearPendingAlerts - name: cpqSm2CntlrSelfTestErrors oid: 1.3.6.1.4.1.232.9.2.2.9 type: gauge help: Remote Insight/ Integrated Lights-Out Self Test Errors - 1.3.6.1.4.1.232.9.2.2.9 - name: cpqSm2CntlrAgentLocation oid: 1.3.6.1.4.1.232.9.2.2.10 type: gauge help: Remote Insight/ Integrated Lights-Out Agent Location - 1.3.6.1.4.1.232.9.2.2.10 enum_values: 1: hostOsAgent 2: firmwareAgent 3: remoteInsightPciFirmwareAgent 4: enclosureFirmwareAgent - name: cpqSm2CntlrLastDataUpdate oid: 1.3.6.1.4.1.232.9.2.2.11 type: OctetString help: The date and time that the Remote Insight/ Integrated Lights-Out offline data was last updated - 1.3.6.1.4.1.232.9.2.2.11 - name: cpqSm2CntlrDataStatus oid: 1.3.6.1.4.1.232.9.2.2.12 type: gauge help: Remote Insight/ Integrated Lights-Out Host OS Data Status - 1.3.6.1.4.1.232.9.2.2.12 enum_values: 1: other 2: noData 3: onlineData 4: offlineData - name: cpqSm2CntlrColdReboot oid: 1.3.6.1.4.1.232.9.2.2.13 type: gauge help: 'Remote Insight/ Integrated Lights-Out Server Cold Reboot The following values are defined: notAvailable(1) Cold reboot of the system is not available - 1.3.6.1.4.1.232.9.2.2.13' enum_values: 1: notAvailable 2: available 3: doColdReboot - name: cpqSm2CntlrBadLoginAttemptsThresh oid: 1.3.6.1.4.1.232.9.2.2.14 type: gauge help: Maximum Unauthorized Login Attempts Threshold - 1.3.6.1.4.1.232.9.2.2.14 - name: cpqSm2CntlrBoardSerialNumber oid: 1.3.6.1.4.1.232.9.2.2.15 type: DisplayString help: Remote Insight/ Integrated Lights-Out Serial Number - 1.3.6.1.4.1.232.9.2.2.15 - name: cpqSm2CntlrRemoteSessionStatus oid: 1.3.6.1.4.1.232.9.2.2.16 type: gauge help: Remote Insight/ Integrated Lights-Out Session Status - 1.3.6.1.4.1.232.9.2.2.16 enum_values: 1: other 2: active 3: inactive - name: cpqSm2CntlrInterfaceStatus oid: 1.3.6.1.4.1.232.9.2.2.17 type: gauge help: Remote Insight/ Integrated Lights-Out Interface Status - 1.3.6.1.4.1.232.9.2.2.17 enum_values: 1: other 2: ok 3: notResponding - name: cpqSm2CntlrSystemId oid: 1.3.6.1.4.1.232.9.2.2.18 type: DisplayString help: Remote Insight/ Integrated Lights-Out System ID - 1.3.6.1.4.1.232.9.2.2.18 - name: cpqSm2CntlrKeyboardCableStatus oid: 1.3.6.1.4.1.232.9.2.2.19 type: gauge help: Remote Insight Keyboard Cable Status - 1.3.6.1.4.1.232.9.2.2.19 enum_values: 1: other 2: connected 3: disconnected - name: cpqSm2ServerIpAddress oid: 1.3.6.1.4.1.232.9.2.2.20 type: InetAddressIPv4 help: The IP address for this servers connection to the Remote Insight/ Integrated Lights-Out - 1.3.6.1.4.1.232.9.2.2.20 - name: cpqSm2CntlrModel oid: 1.3.6.1.4.1.232.9.2.2.21 type: gauge help: Remote Insight/ Integrated Lights-Out Model - 1.3.6.1.4.1.232.9.2.2.21 enum_values: 1: other 2: eisaRemoteInsightBoard 3: pciRemoteInsightBoard 4: pciLightsOutRemoteInsightBoard 5: pciIntegratedLightsOutRemoteInsight 6: pciLightsOutRemoteInsightBoardII 7: pciIntegratedLightsOutRemoteInsight2 8: pciLightsOut100series 9: pciIntegratedLightsOutRemoteInsight3 10: pciIntegratedLightsOutRemoteInsight4 11: pciIntegratedLightsOutRemoteInsight5 - name: cpqSm2CntlrSelfTestErrorMask oid: 1.3.6.1.4.1.232.9.2.2.22 type: gauge help: Remote Insight/ Integrated Lights-Out Self Test Error Mask - 1.3.6.1.4.1.232.9.2.2.22 - name: cpqSm2CntlrMouseCableStatus oid: 1.3.6.1.4.1.232.9.2.2.23 type: gauge help: Remote Insight Mouse Cable Status - 1.3.6.1.4.1.232.9.2.2.23 enum_values: 1: other 2: connected 3: disconnected - name: cpqSm2CntlrVirtualPowerCableStatus oid: 1.3.6.1.4.1.232.9.2.2.24 type: gauge help: Remote Insight Virtual Power Cable Status - 1.3.6.1.4.1.232.9.2.2.24 enum_values: 1: other 2: connected 3: disconnected 4: notApplicable - name: cpqSm2CntlrExternalPowerCableStatus oid: 1.3.6.1.4.1.232.9.2.2.25 type: gauge help: Remote Insight External Power Cable Status - 1.3.6.1.4.1.232.9.2.2.25 enum_values: 1: other 2: externallyConnected 3: disconnected 4: internallyConnected 5: externallyAndInternallyConnected 6: notApplicable - name: cpqSm2CntlrHostGUID oid: 1.3.6.1.4.1.232.9.2.2.26 type: OctetString help: The globally unique identifier of this server - 1.3.6.1.4.1.232.9.2.2.26 - name: cpqSm2CntlriLOSecurityOverrideSwitchState oid: 1.3.6.1.4.1.232.9.2.2.27 type: gauge help: Integrated Lights-Out Security Override Switch State - 1.3.6.1.4.1.232.9.2.2.27 enum_values: 1: notSupported 2: set 3: notSet - name: cpqSm2CntlrHardwareVer oid: 1.3.6.1.4.1.232.9.2.2.28 type: gauge help: Hardware Version of Remote Insight/ Integrated Lights-Out. - 1.3.6.1.4.1.232.9.2.2.28 - name: cpqSm2CntlrAction oid: 1.3.6.1.4.1.232.9.2.2.29 type: gauge help: Remote Insight/ Integrated Lights-Out Action Flags - 1.3.6.1.4.1.232.9.2.2.29 - name: cpqSm2CntlrLicenseActive oid: 1.3.6.1.4.1.232.9.2.2.30 type: gauge help: Remote Insight License State - 1.3.6.1.4.1.232.9.2.2.30 enum_values: 1: none 2: iloAdvanced 3: iloLight 4: iloAdvancedBlade 5: iloStandard 6: iloEssentials 7: iloScaleOut 8: iloAdvancedPremiumSecurity - name: cpqSm2CntlrLicenseKey oid: 1.3.6.1.4.1.232.9.2.2.31 type: DisplayString help: iLO Active ASCII License key string - 1.3.6.1.4.1.232.9.2.2.31 - name: cpqSm2CntlrServerPowerState oid: 1.3.6.1.4.1.232.9.2.2.32 type: gauge help: The current power state for the server - 1.3.6.1.4.1.232.9.2.2.32 enum_values: 1: unknown 2: poweredOff 3: poweredOn 4: insufficientPowerOrPowerOnDenied - name: cpqSm2CntlrSysAutoShutdownCause oid: 1.3.6.1.4.1.232.9.2.2.33 type: gauge help: Indicate the reason for triggering system auto shutdown or cancelling auto shutdown. - 1.3.6.1.4.1.232.9.2.2.33 enum_values: 1: fanFailure 2: overheatCondition 3: vrmFailure 4: powerSupplyFailure 5: systemRunningOnBatteryBackupUnit 129: aborted 130: fanFailureAborted 131: overheatAborted 132: vrmFailureAborted 133: softPowerDown 134: softwareAutomaticServerRecovery 135: powerSupplyFailureAborted - name: cpqSm2CntlrSecurityState oid: 1.3.6.1.4.1.232.9.2.2.34 type: gauge help: Indicate security state - 1.3.6.1.4.1.232.9.2.2.34 enum_values: 1: factory 2: wipe 3: production 4: highSecurity 5: fips 6: cnsa - name: cpqSm2WDTimerType oid: 1.3.6.1.4.1.232.9.2.2.35 type: gauge help: Indicate the watchdog timer type. - 1.3.6.1.4.1.232.9.2.2.35 enum_values: 1: unknown 2: ipmi - name: cpqSm2WDTimerTimeoutDetails oid: 1.3.6.1.4.1.232.9.2.2.36 type: DisplayString help: Indicate the watchdog timer timeout action and timer details. - 1.3.6.1.4.1.232.9.2.2.36 - name: cpqSm2CntlrOverallSecStatus oid: 1.3.6.1.4.1.232.9.2.2.37 type: gauge help: The field indicates the overall security status. - 1.3.6.1.4.1.232.9.2.2.37 enum_values: 1: Ok 2: Risk 3: Ignored version: 2 auth: community: hp_dl380_g10 hpe_walk: walk: - 1.3.6.1.4.1.232.1.2.2.1.1 - 1.3.6.1.4.1.232.11 - 1.3.6.1.4.1.232.14 - 1.3.6.1.4.1.232.3.2.2.1 - 1.3.6.1.4.1.232.3.2.3.1.1 - 1.3.6.1.4.1.232.3.2.5.1.1 - 1.3.6.1.4.1.232.5 - 1.3.6.1.4.1.232.6.2.14.13.1.6 - 1.3.6.1.4.1.232.6.2.15 - 1.3.6.1.4.1.232.6.2.16 - 1.3.6.1.4.1.232.6.2.17 - 1.3.6.1.4.1.232.6.2.6.8.1 - 1.3.6.1.4.1.232.6.2.9 - 1.3.6.1.4.1.232.9.2.2 get: - 1.3.6.1.2.1.1.3.0 metrics: - name: sysUpTime oid: 1.3.6.1.2.1.1.3 type: gauge help: The time (in hundredths of a second) since the network management portion of the system was last re-initialized. - 1.3.6.1.2.1.1.3 - name: cpqSeCpuUnitIndex oid: 1.3.6.1.4.1.232.1.2.2.1.1.1 type: gauge help: This is a number that uniquely specifies a processor unit - 1.3.6.1.4.1.232.1.2.2.1.1.1 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuSlot oid: 1.3.6.1.4.1.232.1.2.2.1.1.2 type: gauge help: This value represents this processor`s slot - 1.3.6.1.4.1.232.1.2.2.1.1.2 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuName oid: 1.3.6.1.4.1.232.1.2.2.1.1.3 type: DisplayString help: The name of this processor - 1.3.6.1.4.1.232.1.2.2.1.1.3 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuSpeed oid: 1.3.6.1.4.1.232.1.2.2.1.1.4 type: gauge help: The current internal speed of this processor in megahertz - 1.3.6.1.4.1.232.1.2.2.1.1.4 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuStep oid: 1.3.6.1.4.1.232.1.2.2.1.1.5 type: gauge help: This step of the processor - 1.3.6.1.4.1.232.1.2.2.1.1.5 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuStatus oid: 1.3.6.1.4.1.232.1.2.2.1.1.6 type: gauge help: The status of the processor - 1.3.6.1.4.1.232.1.2.2.1.1.6 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: ok 3: degraded 4: failed 5: disabled - name: cpqSeCpuExtSpeed oid: 1.3.6.1.4.1.232.1.2.2.1.1.7 type: gauge help: This is the external frequency in megahertz of the processor bus - 1.3.6.1.4.1.232.1.2.2.1.1.7 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuDesigner oid: 1.3.6.1.4.1.232.1.2.2.1.1.8 type: gauge help: This attribute specifies the manufacturer which designs this CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.8 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: intel 3: amd 4: cyrix 5: ti 6: nexgen 7: compaq 8: samsung 9: mitsubishi 10: mips - name: cpqSeCpuSocketNumber oid: 1.3.6.1.4.1.232.1.2.2.1.1.9 type: gauge help: The physical socket number of the CPU chip - 1.3.6.1.4.1.232.1.2.2.1.1.9 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuThreshPassed oid: 1.3.6.1.4.1.232.1.2.2.1.1.10 type: gauge help: CPU threshold passed (Exceeded) - 1.3.6.1.4.1.232.1.2.2.1.1.10 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unsupported 2: "false" 3: "true" - name: cpqSeCpuHwLocation oid: 1.3.6.1.4.1.232.1.2.2.1.1.11 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the CPU - 1.3.6.1.4.1.232.1.2.2.1.1.11 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuCellTablePtr oid: 1.3.6.1.4.1.232.1.2.2.1.1.12 type: gauge help: This is the index for the cell in cpqSeCellTable where this CPU is physically located. - 1.3.6.1.4.1.232.1.2.2.1.1.12 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuPowerpodStatus oid: 1.3.6.1.4.1.232.1.2.2.1.1.13 type: gauge help: This is the status of CPU power pod - 1.3.6.1.4.1.232.1.2.2.1.1.13 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: notfailed 2: failed - name: cpqSeCpuArchitectureRevision oid: 1.3.6.1.4.1.232.1.2.2.1.1.14 type: DisplayString help: This is the CPU architecture revision. - 1.3.6.1.4.1.232.1.2.2.1.1.14 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuCore oid: 1.3.6.1.4.1.232.1.2.2.1.1.15 type: gauge help: The number of cores in this CPU module - 1.3.6.1.4.1.232.1.2.2.1.1.15 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUSerialNumber oid: 1.3.6.1.4.1.232.1.2.2.1.1.16 type: DisplayString help: The OEM serial number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.16 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUPartNumber oid: 1.3.6.1.4.1.232.1.2.2.1.1.17 type: DisplayString help: The OEM part number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.17 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUSerialNumberMfgr oid: 1.3.6.1.4.1.232.1.2.2.1.1.18 type: DisplayString help: The manufacturer serial number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.18 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUPartNumberMfgr oid: 1.3.6.1.4.1.232.1.2.2.1.1.19 type: DisplayString help: The manufacturer part number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.19 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUCoreIndex oid: 1.3.6.1.4.1.232.1.2.2.1.1.20 type: gauge help: This is a number that uniquely identifies a core in a CPU unit. - 1.3.6.1.4.1.232.1.2.2.1.1.20 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUMaxSpeed oid: 1.3.6.1.4.1.232.1.2.2.1.1.21 type: gauge help: This is the maximum internal speed in megahertz this processor can support - 1.3.6.1.4.1.232.1.2.2.1.1.21 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUCoreThreadIndex oid: 1.3.6.1.4.1.232.1.2.2.1.1.22 type: gauge help: This is an unique number to identify the running threads in a CPU core. - 1.3.6.1.4.1.232.1.2.2.1.1.22 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUChipGenerationName oid: 1.3.6.1.4.1.232.1.2.2.1.1.23 type: DisplayString help: CPU chip generation name e.g - 1.3.6.1.4.1.232.1.2.2.1.1.23 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCPUMultiThreadStatus oid: 1.3.6.1.4.1.232.1.2.2.1.1.24 type: gauge help: This OID identifies whether the CPU threading is enabled or not. - 1.3.6.1.4.1.232.1.2.2.1.1.24 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: enabled 3: disabled - name: cpqSeCPUCoreMaxThreads oid: 1.3.6.1.4.1.232.1.2.2.1.1.25 type: gauge help: This OID indicates the maximum number of threads that a cpu core is capable of. - 1.3.6.1.4.1.232.1.2.2.1.1.25 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuLowPowerStatus oid: 1.3.6.1.4.1.232.1.2.2.1.1.26 type: gauge help: Servers like Itanium has capability to lower power supply to CPU if it is idle for specified period of time - 1.3.6.1.4.1.232.1.2.2.1.1.26 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: lowpowered 3: normalpowered 4: highpowered - name: cpqSeCpuPrimary oid: 1.3.6.1.4.1.232.1.2.2.1.1.27 type: gauge help: On SMP systems one of the CPU is set to Primary and the other CPUs as secondary - 1.3.6.1.4.1.232.1.2.2.1.1.27 indexes: - labelname: cpqSeCpuUnitIndex type: gauge enum_values: 1: unknown 2: "false" 3: "true" - name: cpqSeCpuCoreSteppingText oid: 1.3.6.1.4.1.232.1.2.2.1.1.28 type: DisplayString help: The processor stepping version string - 1.3.6.1.4.1.232.1.2.2.1.1.28 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuCurrentPerformanceState oid: 1.3.6.1.4.1.232.1.2.2.1.1.29 type: gauge help: This OID returns the current performance state of this processor - 1.3.6.1.4.1.232.1.2.2.1.1.29 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuMinPerformanceState oid: 1.3.6.1.4.1.232.1.2.2.1.1.30 type: gauge help: This OID returns the minimum performance state set for this processor - 1.3.6.1.4.1.232.1.2.2.1.1.30 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqSeCpuMaxPerformanceState oid: 1.3.6.1.4.1.232.1.2.2.1.1.31 type: gauge help: This OID returns the maximum performance state set for this processor - 1.3.6.1.4.1.232.1.2.2.1.1.31 indexes: - labelname: cpqSeCpuUnitIndex type: gauge - name: cpqHoMibRevMajor oid: 1.3.6.1.4.1.232.11.1.1 type: gauge help: The Major Revision level of the MIB - 1.3.6.1.4.1.232.11.1.1 - name: cpqHoMibRevMinor oid: 1.3.6.1.4.1.232.11.1.2 type: gauge help: The Minor Revision level of the MIB - 1.3.6.1.4.1.232.11.1.2 - name: cpqHoMibCondition oid: 1.3.6.1.4.1.232.11.1.3 type: gauge help: The overall condition - 1.3.6.1.4.1.232.11.1.3 enum_values: 1: unknown 2: ok 3: degraded 4: failed - name: cpqHoOsCommonPollFreq oid: 1.3.6.1.4.1.232.11.2.1.4.1 type: gauge help: The Insight Agent`s polling frequency - 1.3.6.1.4.1.232.11.2.1.4.1 - name: cpqHoOsCommonModuleIndex oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.1 type: gauge help: A unique index for this module description. - 1.3.6.1.4.1.232.11.2.1.4.2.1.1 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoOsCommonModuleName oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.2 type: DisplayString help: The module name. - 1.3.6.1.4.1.232.11.2.1.4.2.1.2 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoOsCommonModuleVersion oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.3 type: DisplayString help: The module version in XX.YY format - 1.3.6.1.4.1.232.11.2.1.4.2.1.3 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoOsCommonModuleDate oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.4 type: OctetString help: The module date - 1.3.6.1.4.1.232.11.2.1.4.2.1.4 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoOsCommonModulePurpose oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.5 type: DisplayString help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.11.2.1.4.2.1.5 indexes: - labelname: cpqHoOsCommonModuleIndex type: gauge - name: cpqHoName oid: 1.3.6.1.4.1.232.11.2.2.1 type: DisplayString help: The name of the host operating system (OS). - 1.3.6.1.4.1.232.11.2.2.1 - name: cpqHoVersion oid: 1.3.6.1.4.1.232.11.2.2.2 type: DisplayString help: The version of the host OS. - 1.3.6.1.4.1.232.11.2.2.2 - name: cpqHoDesc oid: 1.3.6.1.4.1.232.11.2.2.3 type: DisplayString help: A further description of the host OS. - 1.3.6.1.4.1.232.11.2.2.3 - name: cpqHoOsType oid: 1.3.6.1.4.1.232.11.2.2.4 type: gauge help: Host Operating system enumeration. - 1.3.6.1.4.1.232.11.2.2.4 enum_values: 1: other 2: netware 3: windowsnt 4: sco-unix 5: unixware 6: os-2 7: ms-dos 8: dos-windows 9: windows95 10: windows98 11: open-vms 12: nsk 13: windowsCE 14: linux 15: windows2000 16: tru64UNIX 17: windows2003 18: windows2003-x64 19: solaris 20: windows2003-ia64 21: windows2008 22: windows2008-x64 23: windows2008-ia64 24: vmware-esx 25: vmware-esxi 26: windows2012 27: windows7 28: windows7-x64 29: windows8 30: windows8-x64 31: windows81 32: windows81-x64 33: windowsxp 34: windowsxp-x64 35: windowsvista 36: windowsvista-x64 37: windows2008-r2 38: windows2012-r2 39: rhel 40: rhel-64 41: solaris-64 42: sles 43: sles-64 44: ubuntu 45: ubuntu-64 46: debian 47: debian-64 48: linux-64-bit 49: other-64-bit 50: centos-32bit 51: centos-64bit 52: oracle-linux32 53: oracle-linux64 54: apple-osx 55: windows2016 56: nanoserver 57: windows2019 - name: cpqHoTelnet oid: 1.3.6.1.4.1.232.11.2.2.5 type: gauge help: Telnet on socket 23 is available. - 1.3.6.1.4.1.232.11.2.2.5 enum_values: 1: other 2: available 3: notavailable - name: cpqHoSystemRole oid: 1.3.6.1.4.1.232.11.2.2.6 type: DisplayString help: The system role - 1.3.6.1.4.1.232.11.2.2.6 - name: cpqHoSystemRoleDetail oid: 1.3.6.1.4.1.232.11.2.2.7 type: DisplayString help: The system detailed description - 1.3.6.1.4.1.232.11.2.2.7 - name: cpqHoCrashDumpState oid: 1.3.6.1.4.1.232.11.2.2.8 type: gauge help: Crash dump state - 1.3.6.1.4.1.232.11.2.2.8 enum_values: 1: completememorydump 2: kernelmemorydump 3: smallmemorydump 4: none - name: cpqHoCrashDumpCondition oid: 1.3.6.1.4.1.232.11.2.2.9 type: gauge help: The condition of the Crash dump configuration. - 1.3.6.1.4.1.232.11.2.2.9 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHoCrashDumpMonitoring oid: 1.3.6.1.4.1.232.11.2.2.10 type: gauge help: Enable/disable crash dump monitoring - 1.3.6.1.4.1.232.11.2.2.10 enum_values: 1: enabled 2: disabled - name: cpqHoMaxLogicalCPUSupported oid: 1.3.6.1.4.1.232.11.2.2.11 type: gauge help: Maximum number of logical CPUs supported by Operating System. - 1.3.6.1.4.1.232.11.2.2.11 - name: cpqHoSystemName oid: 1.3.6.1.4.1.232.11.2.2.12 type: DisplayString help: Full computer name of the host - 1.3.6.1.4.1.232.11.2.2.12 - name: cpqHosysDescr oid: 1.3.6.1.4.1.232.11.2.2.13 type: DisplayString help: The value that would be returned in the RFC-1213 sysDescr MIB element - 1.3.6.1.4.1.232.11.2.2.13 - name: cpqHoCpuUtilUnitIndex oid: 1.3.6.1.4.1.232.11.2.3.1.1.1 type: gauge help: This number uniquely specifies a processor unit - 1.3.6.1.4.1.232.11.2.3.1.1.1 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilMin oid: 1.3.6.1.4.1.232.11.2.3.1.1.2 type: gauge help: The CPU utilization as a percentage of the theoretical maximum during the last minute - 1.3.6.1.4.1.232.11.2.3.1.1.2 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilFiveMin oid: 1.3.6.1.4.1.232.11.2.3.1.1.3 type: gauge help: The CPU utilization as a percentage of the theoretical maximum during the last five minutes - 1.3.6.1.4.1.232.11.2.3.1.1.3 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilThirtyMin oid: 1.3.6.1.4.1.232.11.2.3.1.1.4 type: gauge help: The CPU utilization as a percentage of the theoretical maximum during the last thirty minutes - 1.3.6.1.4.1.232.11.2.3.1.1.4 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilHour oid: 1.3.6.1.4.1.232.11.2.3.1.1.5 type: gauge help: The CPU utilization as a percentage of the theoretical maximum during the last hour - 1.3.6.1.4.1.232.11.2.3.1.1.5 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoCpuUtilHwLocation oid: 1.3.6.1.4.1.232.11.2.3.1.1.6 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the CPU - 1.3.6.1.4.1.232.11.2.3.1.1.6 indexes: - labelname: cpqHoCpuUtilUnitIndex type: gauge - name: cpqHoFileSysIndex oid: 1.3.6.1.4.1.232.11.2.4.1.1.1 type: gauge help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.4.1.1.1 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysDesc oid: 1.3.6.1.4.1.232.11.2.4.1.1.2 type: DisplayString help: A description of the file system include the GUID. - 1.3.6.1.4.1.232.11.2.4.1.1.2 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysSpaceTotal oid: 1.3.6.1.4.1.232.11.2.4.1.1.3 type: gauge help: The file system size in megabytes - 1.3.6.1.4.1.232.11.2.4.1.1.3 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysSpaceUsed oid: 1.3.6.1.4.1.232.11.2.4.1.1.4 type: gauge help: The megabytes of file system space currently in use - 1.3.6.1.4.1.232.11.2.4.1.1.4 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysPercentSpaceUsed oid: 1.3.6.1.4.1.232.11.2.4.1.1.5 type: gauge help: The percent of file system space currently in use - 1.3.6.1.4.1.232.11.2.4.1.1.5 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysAllocUnitsTotal oid: 1.3.6.1.4.1.232.11.2.4.1.1.6 type: gauge help: The total number of files (directory entries) that can be stored on the file system if a limit exists other than total space used - 1.3.6.1.4.1.232.11.2.4.1.1.6 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysAllocUnitsUsed oid: 1.3.6.1.4.1.232.11.2.4.1.1.7 type: gauge help: The number of files (directory entries) on this file system - 1.3.6.1.4.1.232.11.2.4.1.1.7 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysStatus oid: 1.3.6.1.4.1.232.11.2.4.1.1.8 type: gauge help: The Threshold Status - 1.3.6.1.4.1.232.11.2.4.1.1.8 indexes: - labelname: cpqHoFileSysIndex type: gauge enum_values: 1: unknown 2: ok 3: degraded 4: failed - name: cpqHoFileSysShortDesc oid: 1.3.6.1.4.1.232.11.2.4.1.1.9 type: DisplayString help: A description of the file system. - 1.3.6.1.4.1.232.11.2.4.1.1.9 indexes: - labelname: cpqHoFileSysIndex type: gauge - name: cpqHoFileSysCondition oid: 1.3.6.1.4.1.232.11.2.4.2 type: gauge help: The overall condition of File System Threshold - 1.3.6.1.4.1.232.11.2.4.2 enum_values: 1: unknown 2: ok 3: degraded 4: failed - name: cpqHoIfPhysMapIndex oid: 1.3.6.1.4.1.232.11.2.5.1.1.1 type: gauge help: An index that uniquely specifies this entry - 1.3.6.1.4.1.232.11.2.5.1.1.1 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapSlot oid: 1.3.6.1.4.1.232.11.2.5.1.1.2 type: gauge help: The number of the slot containing the physical hardware that implements this interface - 1.3.6.1.4.1.232.11.2.5.1.1.2 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapIoBaseAddr oid: 1.3.6.1.4.1.232.11.2.5.1.1.3 type: gauge help: The base I/O address of the physical hardware that implements this interface. - 1.3.6.1.4.1.232.11.2.5.1.1.3 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapIrq oid: 1.3.6.1.4.1.232.11.2.5.1.1.4 type: gauge help: The number of the IRQ (interrupt) used for this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.4 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapDma oid: 1.3.6.1.4.1.232.11.2.5.1.1.5 type: gauge help: The number of the DMA channel used for this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.5 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapMemBaseAddr oid: 1.3.6.1.4.1.232.11.2.5.1.1.6 type: gauge help: The base memory address used by this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.6 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapPort oid: 1.3.6.1.4.1.232.11.2.5.1.1.7 type: gauge help: The port number of the interface for multi-port NICs - 1.3.6.1.4.1.232.11.2.5.1.1.7 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge - name: cpqHoIfPhysMapDuplexState oid: 1.3.6.1.4.1.232.11.2.5.1.1.8 type: gauge help: This variable describes the configured duplex state of the NIC. - 1.3.6.1.4.1.232.11.2.5.1.1.8 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge enum_values: 1: other 2: half 3: full - name: cpqHoIfPhysMapCondition oid: 1.3.6.1.4.1.232.11.2.5.1.1.9 type: gauge help: The condition of this interface. - 1.3.6.1.4.1.232.11.2.5.1.1.9 indexes: - labelname: cpqHoIfPhysMapIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHoIfPhysMapOverallCondition oid: 1.3.6.1.4.1.232.11.2.5.2 type: gauge help: The overall condition of all interfaces. - 1.3.6.1.4.1.232.11.2.5.2 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHoSWRunningIndex oid: 1.3.6.1.4.1.232.11.2.6.1.1.1 type: gauge help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.6.1.1.1 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningName oid: 1.3.6.1.4.1.232.11.2.6.1.1.2 type: DisplayString help: The name of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.2 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningDesc oid: 1.3.6.1.4.1.232.11.2.6.1.1.3 type: DisplayString help: A description of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.3 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningVersion oid: 1.3.6.1.4.1.232.11.2.6.1.1.4 type: DisplayString help: The version of the software - 1.3.6.1.4.1.232.11.2.6.1.1.4 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningDate oid: 1.3.6.1.4.1.232.11.2.6.1.1.5 type: OctetString help: The software date - 1.3.6.1.4.1.232.11.2.6.1.1.5 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningMonitor oid: 1.3.6.1.4.1.232.11.2.6.1.1.6 type: gauge help: The user specified monitor option for a process. - 1.3.6.1.4.1.232.11.2.6.1.1.6 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: other 2: start 3: stop 4: startAndStop 5: count 6: startAndCount 7: countAndStop 8: startCountAndStop - name: cpqHoSWRunningState oid: 1.3.6.1.4.1.232.11.2.6.1.1.7 type: gauge help: The current state of monitored process. - 1.3.6.1.4.1.232.11.2.6.1.1.7 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: other 2: started 3: stopped - name: cpqHoSWRunningCount oid: 1.3.6.1.4.1.232.11.2.6.1.1.8 type: gauge help: For each process name, the number of instances of the process running on the system is kept count of, in this variable. - 1.3.6.1.4.1.232.11.2.6.1.1.8 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningCountMin oid: 1.3.6.1.4.1.232.11.2.6.1.1.9 type: gauge help: This is the lower threshold on cpqHoSWRunningCount to be set by the user. - 1.3.6.1.4.1.232.11.2.6.1.1.9 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningCountMax oid: 1.3.6.1.4.1.232.11.2.6.1.1.10 type: gauge help: This is the upper threshold on cpqHoSWRunningCount to be set by the user. - 1.3.6.1.4.1.232.11.2.6.1.1.10 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningEventTime oid: 1.3.6.1.4.1.232.11.2.6.1.1.11 type: OctetString help: The system time at which the monitored event, as per cpqHoSWRunningMonitor, last occurred - 1.3.6.1.4.1.232.11.2.6.1.1.11 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningStatus oid: 1.3.6.1.4.1.232.11.2.6.1.1.12 type: gauge help: The overall alarm state of the resources managed by the software, or the software itself. - 1.3.6.1.4.1.232.11.2.6.1.1.12 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: unknown 2: normal 3: warning 4: minor 5: major 6: critical 7: disabled - name: cpqHoSWRunningConfigStatus oid: 1.3.6.1.4.1.232.11.2.6.1.1.13 type: gauge help: The configuration state of the software - 1.3.6.1.4.1.232.11.2.6.1.1.13 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: unknown 2: starting 3: initialized 4: configured 5: operational - name: cpqHoSWRunningIdentifier oid: 1.3.6.1.4.1.232.11.2.6.1.1.14 type: DisplayString help: The unique identifier of the sofware - 1.3.6.1.4.1.232.11.2.6.1.1.14 indexes: - labelname: cpqHoSWRunningIndex type: gauge - name: cpqHoSWRunningRedundancyMode oid: 1.3.6.1.4.1.232.11.2.6.1.1.15 type: gauge help: When the software is running in a high availability mode, the failover mode of this instance of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.15 indexes: - labelname: cpqHoSWRunningIndex type: gauge enum_values: 1: unknown 2: master 3: backup 4: slave - name: cpqHoSwRunningTrapDesc oid: 1.3.6.1.4.1.232.11.2.6.2 type: DisplayString help: The error message for a process monitor event. - 1.3.6.1.4.1.232.11.2.6.2 - name: cpqHoSwVerNextIndex oid: 1.3.6.1.4.1.232.11.2.7.1 type: gauge help: The index of the next available entry in the cpqHoSwVer table - 1.3.6.1.4.1.232.11.2.7.1 - name: cpqHoSwVerIndex oid: 1.3.6.1.4.1.232.11.2.7.2.1.1 type: gauge help: An index that uniquely identifies an entry in the cpqHoSwVer table. - 1.3.6.1.4.1.232.11.2.7.2.1.1 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerStatus oid: 1.3.6.1.4.1.232.11.2.7.2.1.2 type: gauge help: Status for the software item. - 1.3.6.1.4.1.232.11.2.7.2.1.2 indexes: - labelname: cpqHoSwVerIndex type: gauge enum_values: 1: other 2: loaded 3: notloaded - name: cpqHoSwVerType oid: 1.3.6.1.4.1.232.11.2.7.2.1.3 type: gauge help: Type of software item. - 1.3.6.1.4.1.232.11.2.7.2.1.3 indexes: - labelname: cpqHoSwVerIndex type: gauge enum_values: 1: other 2: driver 3: agent 4: sysutil 5: application 6: keyfile 7: firmware - name: cpqHoSwVerName oid: 1.3.6.1.4.1.232.11.2.7.2.1.4 type: DisplayString help: The name of this software item. - 1.3.6.1.4.1.232.11.2.7.2.1.4 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerDescription oid: 1.3.6.1.4.1.232.11.2.7.2.1.5 type: DisplayString help: The description of this software item. - 1.3.6.1.4.1.232.11.2.7.2.1.5 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerDate oid: 1.3.6.1.4.1.232.11.2.7.2.1.6 type: OctetString help: The date of the software item, if any - 1.3.6.1.4.1.232.11.2.7.2.1.6 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerLocation oid: 1.3.6.1.4.1.232.11.2.7.2.1.7 type: DisplayString help: The location of this software item on the server. - 1.3.6.1.4.1.232.11.2.7.2.1.7 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerVersion oid: 1.3.6.1.4.1.232.11.2.7.2.1.8 type: DisplayString help: An string that specifies the version of this item. - 1.3.6.1.4.1.232.11.2.7.2.1.8 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerVersionBinary oid: 1.3.6.1.4.1.232.11.2.7.2.1.9 type: DisplayString help: An string that specifies the version of this item based on the binary version resource. - 1.3.6.1.4.1.232.11.2.7.2.1.9 indexes: - labelname: cpqHoSwVerIndex type: gauge - name: cpqHoSwVerAgentsVer oid: 1.3.6.1.4.1.232.11.2.7.3 type: DisplayString help: A string that specifies the version of the Insight Management Agents running on the system. - 1.3.6.1.4.1.232.11.2.7.3 - name: cpqHoGenericData oid: 1.3.6.1.4.1.232.11.2.8.1 type: DisplayString help: Data for the generic trap. - 1.3.6.1.4.1.232.11.2.8.1 - name: cpqHoCriticalSoftwareUpdateData oid: 1.3.6.1.4.1.232.11.2.8.2 type: DisplayString help: Data for the Critical Software Update trap. - 1.3.6.1.4.1.232.11.2.8.2 - name: cpqHoSwPerfAppErrorDesc oid: 1.3.6.1.4.1.232.11.2.9.1 type: DisplayString help: This string holds error information about the last application error that occurred in the system. - 1.3.6.1.4.1.232.11.2.9.1 - name: cpqHoMibStatusArray oid: 1.3.6.1.4.1.232.11.2.10.1 type: OctetString help: The MIB Status Array is an array of MIB status structures - 1.3.6.1.4.1.232.11.2.10.1 - name: cpqHoConfigChangedDate oid: 1.3.6.1.4.1.232.11.2.10.2 type: OctetString help: The date/time when the agents were last loaded - 1.3.6.1.4.1.232.11.2.10.2 - name: cpqHoGUID oid: 1.3.6.1.4.1.232.11.2.10.3 type: OctetString help: The globally unique identifier of this physical server - 1.3.6.1.4.1.232.11.2.10.3 - name: cpqHoCodeServer oid: 1.3.6.1.4.1.232.11.2.10.4 type: gauge help: This item indicates how many code server shares are currently configured on the system - 1.3.6.1.4.1.232.11.2.10.4 - name: cpqHoWebMgmtPort oid: 1.3.6.1.4.1.232.11.2.10.5 type: gauge help: This item indicates the port used by the Insight Web Agent - 1.3.6.1.4.1.232.11.2.10.5 - name: cpqHoGUIDCanonical oid: 1.3.6.1.4.1.232.11.2.10.6 type: OctetString help: The globally unique identifier in canonical format of this physical server - 1.3.6.1.4.1.232.11.2.10.6 - name: cpqHoMibHealthStatusArray oid: 1.3.6.1.4.1.232.11.2.10.7 type: OctetString help: 'The MIB Health Status Array is an array of status values representing an overall status in element 0 follwed by server and storage status values as follows: Octet Element Field ======== ======= ========= 0 0 Aggregated Status of array elements 1 1 Status of element 1 2 2 Status of element 2 - 1.3.6.1.4.1.232.11.2.10.7' - name: cpqHoTrapFlags oid: 1.3.6.1.4.1.232.11.2.11.1 type: gauge help: The Trap Flags - 1.3.6.1.4.1.232.11.2.11.1 - name: cpqHoClientLastModified oid: 1.3.6.1.4.1.232.11.2.12.1 type: OctetString help: The date/time of the last modification to the client table - 1.3.6.1.4.1.232.11.2.12.1 - name: cpqHoClientDelete oid: 1.3.6.1.4.1.232.11.2.12.2 type: DisplayString help: Setting this variable to the name of a client in the client table will cause that row in the table to be deleted - 1.3.6.1.4.1.232.11.2.12.2 - name: cpqHoClientIndex oid: 1.3.6.1.4.1.232.11.2.12.3.1.1 type: gauge help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.12.3.1.1 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientName oid: 1.3.6.1.4.1.232.11.2.12.3.1.2 type: DisplayString help: The Win95 machine name of this client. - 1.3.6.1.4.1.232.11.2.12.3.1.2 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientIpxAddress oid: 1.3.6.1.4.1.232.11.2.12.3.1.3 type: OctetString help: The IPX address for this client, all octets should be set to 0xff if this machine does not support IPX - 1.3.6.1.4.1.232.11.2.12.3.1.3 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientIpAddress oid: 1.3.6.1.4.1.232.11.2.12.3.1.4 type: InetAddressIPv4 help: The IP address for this client, all octets should be set to 0xff if this machine does not support IP - 1.3.6.1.4.1.232.11.2.12.3.1.4 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientCommunity oid: 1.3.6.1.4.1.232.11.2.12.3.1.5 type: DisplayString help: A community name that can be used to query the client with SNMP - 1.3.6.1.4.1.232.11.2.12.3.1.5 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoClientID oid: 1.3.6.1.4.1.232.11.2.12.3.1.6 type: OctetString help: The unique identifier of this client. - 1.3.6.1.4.1.232.11.2.12.3.1.6 indexes: - labelname: cpqHoClientIndex type: gauge - name: cpqHoPhysicalMemorySize oid: 1.3.6.1.4.1.232.11.2.13.1 type: gauge help: Total amount of physical memory as seen by the OS (in megabytes) - 1.3.6.1.4.1.232.11.2.13.1 - name: cpqHoPhysicalMemoryFree oid: 1.3.6.1.4.1.232.11.2.13.2 type: gauge help: The amount of free physical memory (in megabytes) - 1.3.6.1.4.1.232.11.2.13.2 - name: cpqHoPagingMemorySize oid: 1.3.6.1.4.1.232.11.2.13.3 type: gauge help: Total virtual memory available from the OS (in megabytes) - 1.3.6.1.4.1.232.11.2.13.3 - name: cpqHoPagingMemoryFree oid: 1.3.6.1.4.1.232.11.2.13.4 type: gauge help: Available paging memory (in megabytes) - 1.3.6.1.4.1.232.11.2.13.4 - name: cpqHoBootPagingFileSize oid: 1.3.6.1.4.1.232.11.2.13.5 type: DisplayString help: The paging file size of the boot volume in the format xxxMB or xxxGB, where xxx is the paging file size in that unit shown right after it - 1.3.6.1.4.1.232.11.2.13.5 - name: cpqHoBootPagingFileMinimumSize oid: 1.3.6.1.4.1.232.11.2.13.6 type: DisplayString help: Minimum paging file size of the boot volume required to save the memory dump in the event of a system crash - 1.3.6.1.4.1.232.11.2.13.6 - name: cpqHoBootPagingFileVolumeFreeSpace oid: 1.3.6.1.4.1.232.11.2.13.7 type: DisplayString help: Free space of the boot volume required to save the memory dump in the event of a system crash - 1.3.6.1.4.1.232.11.2.13.7 - name: cpqHoFwVerIndex oid: 1.3.6.1.4.1.232.11.2.14.1.1.1 type: gauge help: Firmware Version Index - 1.3.6.1.4.1.232.11.2.14.1.1.1 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerCategory oid: 1.3.6.1.4.1.232.11.2.14.1.1.2 type: gauge help: Firmware Version Category. - 1.3.6.1.4.1.232.11.2.14.1.1.2 indexes: - labelname: cpqHoFwVerIndex type: gauge enum_values: 1: other 2: storage 3: nic 4: rib 5: system - name: cpqHoFwVerDeviceType oid: 1.3.6.1.4.1.232.11.2.14.1.1.3 type: gauge help: Firmware Version Device Type. - 1.3.6.1.4.1.232.11.2.14.1.1.3 indexes: - labelname: cpqHoFwVerIndex type: gauge enum_values: 1: other 2: internalArrayController 3: fibreArrayController 4: scsiController 5: fibreChannelTapeController 6: modularDataRouter 7: ideCdRomDrive 8: ideDiskDrive 9: scsiCdRom-ScsiAttached 10: scsiDiskDrive-ScsiAttached 11: scsiTapeDrive-ScsiAttached 12: scsiTapeLibrary-ScsiAttached 13: scsiDiskDrive-ArrayAttached 14: scsiTapeDrive-ArrayAttached 15: scsiTapeLibrary-ArrayAttached 16: scsiDiskDrive-FibreAttached 17: scsiTapeDrive-FibreAttached 18: scsiTapeLibrary-FibreAttached 19: scsiEnclosureBackplaneRom-ScsiAttached 20: scsiEnclosureBackplaneRom-ArrayAttached 21: scsiEnclosureBackplaneRom-FibreAttached 22: scsiEnclosureBackplaneRom-ra4x00 23: systemRom 24: networkInterfaceController 25: remoteInsightBoard 26: sasDiskDrive-SasAttached 27: sataDiskDrive-SataAttached 28: usbController 29: sasControllerAdapter 30: sataControllerAdapter 31: systemDevice 32: fibreChannelHba 33: convergedNetworkAdapter 34: ideController - name: cpqHoFwVerDisplayName oid: 1.3.6.1.4.1.232.11.2.14.1.1.4 type: DisplayString help: Firmware Version Device Display Name - 1.3.6.1.4.1.232.11.2.14.1.1.4 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerVersion oid: 1.3.6.1.4.1.232.11.2.14.1.1.5 type: DisplayString help: Firmware Version - 1.3.6.1.4.1.232.11.2.14.1.1.5 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerLocation oid: 1.3.6.1.4.1.232.11.2.14.1.1.6 type: DisplayString help: Firmware Version Device Location - 1.3.6.1.4.1.232.11.2.14.1.1.6 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerXmlString oid: 1.3.6.1.4.1.232.11.2.14.1.1.7 type: DisplayString help: Firmware Version Xml String - 1.3.6.1.4.1.232.11.2.14.1.1.7 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerKeyString oid: 1.3.6.1.4.1.232.11.2.14.1.1.8 type: DisplayString help: Firmware Version Key String - 1.3.6.1.4.1.232.11.2.14.1.1.8 indexes: - labelname: cpqHoFwVerIndex type: gauge - name: cpqHoFwVerUpdateMethod oid: 1.3.6.1.4.1.232.11.2.14.1.1.9 type: gauge help: Firmware Version update method. - 1.3.6.1.4.1.232.11.2.14.1.1.9 indexes: - labelname: cpqHoFwVerIndex type: gauge enum_values: 1: other 2: noUpdate 3: softwareflash 4: replacePhysicalRom - name: cpqHoHWInfoPlatform oid: 1.3.6.1.4.1.232.11.2.15.1 type: gauge help: Hardware platform type - 1.3.6.1.4.1.232.11.2.15.1 enum_values: 1: unknown 2: cellular 3: foundation 4: virtualMachine 5: serverBlade - name: cpqPwrWarnType oid: 1.3.6.1.4.1.232.11.2.16.1 type: DisplayString help: Type of power reading on which the warning is based. - 1.3.6.1.4.1.232.11.2.16.1 - name: cpqPwrWarnThreshold oid: 1.3.6.1.4.1.232.11.2.16.2 type: gauge help: The threshold the power usage must exceed (in Watts). - 1.3.6.1.4.1.232.11.2.16.2 - name: cpqPwrWarnDuration oid: 1.3.6.1.4.1.232.11.2.16.3 type: gauge help: Duration that power usage must be exceeded before warning (in minutes). - 1.3.6.1.4.1.232.11.2.16.3 - name: cpqSerialNum oid: 1.3.6.1.4.1.232.11.2.16.4 type: DisplayString help: Serial number of the server. - 1.3.6.1.4.1.232.11.2.16.4 - name: cpqServerUUID oid: 1.3.6.1.4.1.232.11.2.16.5 type: DisplayString help: Server UUID - 1.3.6.1.4.1.232.11.2.16.5 - name: cpqIdeMibRevMajor oid: 1.3.6.1.4.1.232.14.1.1 type: gauge help: The Major Revision level - 1.3.6.1.4.1.232.14.1.1 - name: cpqIdeMibRevMinor oid: 1.3.6.1.4.1.232.14.1.2 type: gauge help: The Minor Revision level - 1.3.6.1.4.1.232.14.1.2 - name: cpqIdeMibCondition oid: 1.3.6.1.4.1.232.14.1.3 type: gauge help: The overall condition - 1.3.6.1.4.1.232.14.1.3 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeOsCommonPollFreq oid: 1.3.6.1.4.1.232.14.2.1.4.1 type: gauge help: The Insight Agent`s polling frequency - 1.3.6.1.4.1.232.14.2.1.4.1 - name: cpqIdeOsCommonModuleIndex oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.1 type: gauge help: A unique index for this module description. - 1.3.6.1.4.1.232.14.2.1.4.2.1.1 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeOsCommonModuleName oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.2 type: DisplayString help: The module name. - 1.3.6.1.4.1.232.14.2.1.4.2.1.2 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeOsCommonModuleVersion oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.3 type: DisplayString help: The module version in XX.YY format - 1.3.6.1.4.1.232.14.2.1.4.2.1.3 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeOsCommonModuleDate oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.4 type: OctetString help: The module date - 1.3.6.1.4.1.232.14.2.1.4.2.1.4 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeOsCommonModulePurpose oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.5 type: DisplayString help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.14.2.1.4.2.1.5 indexes: - labelname: cpqIdeOsCommonModuleIndex type: gauge - name: cpqIdeIdentIndex oid: 1.3.6.1.4.1.232.14.2.2.1.1.1 type: gauge help: An index that uniquely specifies each device - 1.3.6.1.4.1.232.14.2.2.1.1.1 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentModel oid: 1.3.6.1.4.1.232.14.2.2.1.1.2 type: DisplayString help: IDE Drive Model - 1.3.6.1.4.1.232.14.2.2.1.1.2 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentSerNum oid: 1.3.6.1.4.1.232.14.2.2.1.1.3 type: DisplayString help: IDE Drive Serial Number - 1.3.6.1.4.1.232.14.2.2.1.1.3 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentFWVers oid: 1.3.6.1.4.1.232.14.2.2.1.1.4 type: DisplayString help: IDE Firmware Version - 1.3.6.1.4.1.232.14.2.2.1.1.4 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentCondition oid: 1.3.6.1.4.1.232.14.2.2.1.1.5 type: gauge help: IDE Drive Condition - 1.3.6.1.4.1.232.14.2.2.1.1.5 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeIdentErrorNumber oid: 1.3.6.1.4.1.232.14.2.2.1.1.6 type: DisplayString help: IDE Error Number - 1.3.6.1.4.1.232.14.2.2.1.1.6 indexes: - labelname: cpqIdeIdentIndex type: gauge - name: cpqIdeIdentType oid: 1.3.6.1.4.1.232.14.2.2.1.1.7 type: gauge help: IDE Device Type - 1.3.6.1.4.1.232.14.2.2.1.1.7 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: disk 3: tape 4: printer 5: processor 6: wormDrive 7: cd-rom 8: scanner 9: optical 10: jukeBox 11: commDev - name: cpqIdeIdentTypeExtended oid: 1.3.6.1.4.1.232.14.2.2.1.1.8 type: gauge help: IDE Extended Device Type - 1.3.6.1.4.1.232.14.2.2.1.1.8 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: pdcd 3: removableDisk - name: cpqIdeIdentCondition2 oid: 1.3.6.1.4.1.232.14.2.2.1.1.9 type: gauge help: IDE Drive Condition - 1.3.6.1.4.1.232.14.2.2.1.1.9 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeIdentStatus oid: 1.3.6.1.4.1.232.14.2.2.1.1.10 type: gauge help: IDE Drive Satus - 1.3.6.1.4.1.232.14.2.2.1.1.10 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: ok 3: preFailureDegraded 4: ultraAtaDegraded - name: cpqIdeIdentUltraAtaAvailability oid: 1.3.6.1.4.1.232.14.2.2.1.1.11 type: gauge help: This describes the availability of Ultra ATA transfers between this device and the controller - 1.3.6.1.4.1.232.14.2.2.1.1.11 indexes: - labelname: cpqIdeIdentIndex type: gauge enum_values: 1: other 2: noNotSupportedByDeviceAndController 3: noNotSupportedByDevice 4: noNotSupportedByController 5: noDisabledInSetup 6: yesEnabledInSetup - name: cpqIdeControllerIndex oid: 1.3.6.1.4.1.232.14.2.3.1.1.1 type: gauge help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.3.1.1.1 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerOverallCondition oid: 1.3.6.1.4.1.232.14.2.3.1.1.2 type: gauge help: IDE Controller Overall Condition - 1.3.6.1.4.1.232.14.2.3.1.1.2 indexes: - labelname: cpqIdeControllerIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeControllerModel oid: 1.3.6.1.4.1.232.14.2.3.1.1.3 type: DisplayString help: IDE Controller Model - 1.3.6.1.4.1.232.14.2.3.1.1.3 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerFwRev oid: 1.3.6.1.4.1.232.14.2.3.1.1.4 type: DisplayString help: IDE Controller Firmware Revision - 1.3.6.1.4.1.232.14.2.3.1.1.4 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerSlot oid: 1.3.6.1.4.1.232.14.2.3.1.1.5 type: gauge help: IDE Controller Slot - 1.3.6.1.4.1.232.14.2.3.1.1.5 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerStatus oid: 1.3.6.1.4.1.232.14.2.3.1.1.6 type: gauge help: IDE Channel Host Controller Status - 1.3.6.1.4.1.232.14.2.3.1.1.6 indexes: - labelname: cpqIdeControllerIndex type: gauge enum_values: 1: other 2: ok 3: failed - name: cpqIdeControllerCondition oid: 1.3.6.1.4.1.232.14.2.3.1.1.7 type: gauge help: IDE Controller Condition - 1.3.6.1.4.1.232.14.2.3.1.1.7 indexes: - labelname: cpqIdeControllerIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeControllerSerialNumber oid: 1.3.6.1.4.1.232.14.2.3.1.1.8 type: DisplayString help: IDE Controller Serial Number - 1.3.6.1.4.1.232.14.2.3.1.1.8 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerHwLocation oid: 1.3.6.1.4.1.232.14.2.3.1.1.9 type: DisplayString help: IDE Controller Hardware Location - 1.3.6.1.4.1.232.14.2.3.1.1.9 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeControllerPciLocation oid: 1.3.6.1.4.1.232.14.2.3.1.1.10 type: DisplayString help: IDE Controller PCI Location - 1.3.6.1.4.1.232.14.2.3.1.1.10 indexes: - labelname: cpqIdeControllerIndex type: gauge - name: cpqIdeAtaDiskControllerIndex oid: 1.3.6.1.4.1.232.14.2.4.1.1.1 type: gauge help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.4.1.1.1 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskIndex oid: 1.3.6.1.4.1.232.14.2.4.1.1.2 type: gauge help: An index that uniquely identifies each disk. - 1.3.6.1.4.1.232.14.2.4.1.1.2 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskModel oid: 1.3.6.1.4.1.232.14.2.4.1.1.3 type: DisplayString help: ATA Disk Model - 1.3.6.1.4.1.232.14.2.4.1.1.3 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskFwRev oid: 1.3.6.1.4.1.232.14.2.4.1.1.4 type: DisplayString help: ATA Disk Firmware Revision - 1.3.6.1.4.1.232.14.2.4.1.1.4 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskSerialNumber oid: 1.3.6.1.4.1.232.14.2.4.1.1.5 type: DisplayString help: ATA Disk Serial Number - 1.3.6.1.4.1.232.14.2.4.1.1.5 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskStatus oid: 1.3.6.1.4.1.232.14.2.4.1.1.6 type: gauge help: ATA Disk Status - 1.3.6.1.4.1.232.14.2.4.1.1.6 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: ok 3: smartError 4: failed 5: ssdWearOut - name: cpqIdeAtaDiskCondition oid: 1.3.6.1.4.1.232.14.2.4.1.1.7 type: gauge help: ATA Disk Condition - 1.3.6.1.4.1.232.14.2.4.1.1.7 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeAtaDiskCapacity oid: 1.3.6.1.4.1.232.14.2.4.1.1.8 type: gauge help: ATA Disk Capacity - 1.3.6.1.4.1.232.14.2.4.1.1.8 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskSmartEnabled oid: 1.3.6.1.4.1.232.14.2.4.1.1.9 type: gauge help: ATA Disk S.M.A.R.T Enabled? other(1) The agent cannot determine the state of S.M.A.R.T - 1.3.6.1.4.1.232.14.2.4.1.1.9 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqIdeAtaDiskTransferMode oid: 1.3.6.1.4.1.232.14.2.4.1.1.10 type: gauge help: ATA Disk Transfer Mode - 1.3.6.1.4.1.232.14.2.4.1.1.10 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: pioMode0 3: pioMode1 4: pioMode2 5: pioMode3 6: pioMode4 7: dmaMode0 8: dmaMode1 9: dmaMode2 10: ultraDmaMode0 11: ultraDmaMode1 12: ultraDmaMode2 13: ultraDmaMode3 14: ultraDmaMode4 15: ultraDmaMode5 - name: cpqIdeAtaDiskChannel oid: 1.3.6.1.4.1.232.14.2.4.1.1.11 type: gauge help: ATA Disk Channel - 1.3.6.1.4.1.232.14.2.4.1.1.11 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: channel0 3: channel1 4: serial - name: cpqIdeAtaDiskNumber oid: 1.3.6.1.4.1.232.14.2.4.1.1.12 type: gauge help: ATA Disk Number - 1.3.6.1.4.1.232.14.2.4.1.1.12 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: device0 3: device1 4: sataDevice0 5: sataDevice1 6: sataDevice2 7: sataDevice3 8: sataDevice4 9: sataDevice5 10: sataDevice6 11: sataDevice7 21: bay1 22: bay2 23: bay3 24: bay4 25: bay5 26: bay6 27: bay7 28: bay8 29: bay9 30: bay10 31: bay11 32: bay12 33: bay13 34: bay14 - name: cpqIdeAtaDiskLogicalDriveMember oid: 1.3.6.1.4.1.232.14.2.4.1.1.13 type: gauge help: Logical Drive Membership? other(1) The agent cannot determine if the ATA disk is part of a logical drive - 1.3.6.1.4.1.232.14.2.4.1.1.13 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqIdeAtaDiskIsSpare oid: 1.3.6.1.4.1.232.14.2.4.1.1.14 type: gauge help: ATA Disk Spare? other(1) The agent cannot determine if the ATA disk is a spare - 1.3.6.1.4.1.232.14.2.4.1.1.14 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqIdeAtaDiskOsName oid: 1.3.6.1.4.1.232.14.2.4.1.1.15 type: DisplayString help: ATA Disk OS Name - 1.3.6.1.4.1.232.14.2.4.1.1.15 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskType oid: 1.3.6.1.4.1.232.14.2.4.1.1.16 type: gauge help: ATA Disk Type other(1) The agent cannot determine the disk type - 1.3.6.1.4.1.232.14.2.4.1.1.16 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: ata 3: sata - name: cpqIdeAtaDiskSataVersion oid: 1.3.6.1.4.1.232.14.2.4.1.1.17 type: gauge help: Physical Drive SATA Version - 1.3.6.1.4.1.232.14.2.4.1.1.17 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: sataOne 3: sataTwo - name: cpqIdeAtaDiskMediaType oid: 1.3.6.1.4.1.232.14.2.4.1.1.18 type: gauge help: SATA Physical Drive Media Type - 1.3.6.1.4.1.232.14.2.4.1.1.18 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: rotatingPlatters 3: solidState - name: cpqIdeAtaDiskSSDWearStatus oid: 1.3.6.1.4.1.232.14.2.4.1.1.19 type: gauge help: SATA Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.14.2.4.1.1.19 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge enum_values: 1: other 2: ok 3: fiftySixDayThreshold 4: fivePercentThreshold 5: twoPercentThreshold 6: ssdWearOut - name: cpqIdeAtaDiskPowerOnHours oid: 1.3.6.1.4.1.232.14.2.4.1.1.20 type: counter help: SATA Physical Drive Power On Hours - 1.3.6.1.4.1.232.14.2.4.1.1.20 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskSSDPercntEndrnceUsed oid: 1.3.6.1.4.1.232.14.2.4.1.1.21 type: gauge help: SATA Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.14.2.4.1.1.21 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskSSDEstTimeRemainingHours oid: 1.3.6.1.4.1.232.14.2.4.1.1.22 type: counter help: SATA Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.14.2.4.1.1.22 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskCurrTemperature oid: 1.3.6.1.4.1.232.14.2.4.1.1.23 type: gauge help: SATA Physical Drive Current Operating Temperature degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.23 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskTemperatureThreshold oid: 1.3.6.1.4.1.232.14.2.4.1.1.24 type: gauge help: SATA Physical Drive Maximum Operating Temperature in degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.24 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskMaximumOperatingTemp oid: 1.3.6.1.4.1.232.14.2.4.1.1.25 type: gauge help: SATA Physical Drive Maximum Operating Temperature, as specified by the manufacturer, in degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.25 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaDiskDestructiveOperatingTemp oid: 1.3.6.1.4.1.232.14.2.4.1.1.26 type: gauge help: SATA Physical Drive Destructive Operating Temperature, as specified by the manufacturer, in degrees Celsius, which if exceeded can cause damage to the drive - 1.3.6.1.4.1.232.14.2.4.1.1.26 indexes: - labelname: cpqIdeAtaDiskControllerIndex type: gauge - labelname: cpqIdeAtaDiskIndex type: gauge - name: cpqIdeAtaEraseFailureType oid: 1.3.6.1.4.1.232.14.2.4.2 type: gauge help: The value specifies the secure erase status of SATA drive - 1.3.6.1.4.1.232.14.2.4.2 enum_values: 1: secureEraseFailed 2: secureEraseNotSupported 3: noEraseSupported - name: cpqIdeAtapiDeviceControllerIndex oid: 1.3.6.1.4.1.232.14.2.5.1.1.1 type: gauge help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.5.1.1.1 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge - name: cpqIdeAtapiDeviceIndex oid: 1.3.6.1.4.1.232.14.2.5.1.1.2 type: gauge help: An index that uniquely identifies each ATAPI device. - 1.3.6.1.4.1.232.14.2.5.1.1.2 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge - name: cpqIdeAtapiDeviceModel oid: 1.3.6.1.4.1.232.14.2.5.1.1.3 type: DisplayString help: ATAPI Device Model - 1.3.6.1.4.1.232.14.2.5.1.1.3 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge - name: cpqIdeAtapiDeviceFwRev oid: 1.3.6.1.4.1.232.14.2.5.1.1.4 type: DisplayString help: ATAPI Device Firmware Revision - 1.3.6.1.4.1.232.14.2.5.1.1.4 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge - name: cpqIdeAtapiDeviceType oid: 1.3.6.1.4.1.232.14.2.5.1.1.5 type: gauge help: ATAPI Device Type - 1.3.6.1.4.1.232.14.2.5.1.1.5 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge enum_values: 1: other 2: disk 3: tape 4: printer 5: processor 6: wormDrive 7: cd-rom 8: scanner 9: optical 10: jukeBox 11: commDev - name: cpqIdeAtapiDeviceTypeExtended oid: 1.3.6.1.4.1.232.14.2.5.1.1.6 type: gauge help: ATAPI Extended Device Type - 1.3.6.1.4.1.232.14.2.5.1.1.6 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge enum_values: 1: other 2: pdcd 3: removableDisk - name: cpqIdeAtapiDeviceChannel oid: 1.3.6.1.4.1.232.14.2.5.1.1.7 type: gauge help: ATAPI Device Channel - 1.3.6.1.4.1.232.14.2.5.1.1.7 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge enum_values: 1: other 2: channel0 3: channel1 - name: cpqIdeAtapiDeviceNumber oid: 1.3.6.1.4.1.232.14.2.5.1.1.8 type: gauge help: ATAPI Device Number - 1.3.6.1.4.1.232.14.2.5.1.1.8 indexes: - labelname: cpqIdeAtapiDeviceControllerIndex type: gauge - labelname: cpqIdeAtapiDeviceIndex type: gauge enum_values: 1: other 2: device0 3: device1 - name: cpqIdeLogicalDriveControllerIndex oid: 1.3.6.1.4.1.232.14.2.6.1.1.1 type: gauge help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.6.1.1.1 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveIndex oid: 1.3.6.1.4.1.232.14.2.6.1.1.2 type: gauge help: An index that uniquely identifies each logical drive. - 1.3.6.1.4.1.232.14.2.6.1.1.2 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveRaidLevel oid: 1.3.6.1.4.1.232.14.2.6.1.1.3 type: gauge help: IDE Logical Drive RAID Level - 1.3.6.1.4.1.232.14.2.6.1.1.3 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge enum_values: 1: other 2: raid0 3: raid1 4: raid0plus1 5: raid5 6: raid15 7: volume - name: cpqIdeLogicalDriveCapacity oid: 1.3.6.1.4.1.232.14.2.6.1.1.4 type: gauge help: IDE Logical Drive Capacity - 1.3.6.1.4.1.232.14.2.6.1.1.4 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveStatus oid: 1.3.6.1.4.1.232.14.2.6.1.1.5 type: gauge help: IDE Logical Drive Status - 1.3.6.1.4.1.232.14.2.6.1.1.5 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: rebuilding 5: failed - name: cpqIdeLogicalDriveCondition oid: 1.3.6.1.4.1.232.14.2.6.1.1.6 type: gauge help: IDE Logical Drive Condition - 1.3.6.1.4.1.232.14.2.6.1.1.6 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqIdeLogicalDriveDiskIds oid: 1.3.6.1.4.1.232.14.2.6.1.1.7 type: OctetString help: IDE Logical Drive Disk ID list - 1.3.6.1.4.1.232.14.2.6.1.1.7 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveStripeSize oid: 1.3.6.1.4.1.232.14.2.6.1.1.8 type: gauge help: IDE Logical Drive Stripe Size - 1.3.6.1.4.1.232.14.2.6.1.1.8 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveSpareIds oid: 1.3.6.1.4.1.232.14.2.6.1.1.9 type: OctetString help: IDE Logical Drive Spare ID list - 1.3.6.1.4.1.232.14.2.6.1.1.9 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveRebuildingDisk oid: 1.3.6.1.4.1.232.14.2.6.1.1.10 type: gauge help: IDE Logical Drive Rebuilding Disk - 1.3.6.1.4.1.232.14.2.6.1.1.10 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqIdeLogicalDriveOsName oid: 1.3.6.1.4.1.232.14.2.6.1.1.11 type: DisplayString help: IDE Logical Drive OS Name - 1.3.6.1.4.1.232.14.2.6.1.1.11 indexes: - labelname: cpqIdeLogicalDriveControllerIndex type: gauge - labelname: cpqIdeLogicalDriveIndex type: gauge - name: cpqDaCntlrIndex oid: 1.3.6.1.4.1.232.3.2.2.1.1.1 type: gauge help: Array Controller Index - 1.3.6.1.4.1.232.3.2.2.1.1.1 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrModel oid: 1.3.6.1.4.1.232.3.2.2.1.1.2 type: gauge help: Array Controller Model - 1.3.6.1.4.1.232.3.2.2.1.1.2 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ida 3: idaExpansion 4: ida-2 5: smart 6: smart-2e 7: smart-2p 8: smart-2sl 9: smart-3100es 10: smart-3200 11: smart-2dh 12: smart-221 13: sa-4250es 14: sa-4200 15: sa-integrated 16: sa-431 17: sa-5300 18: raidLc2 19: sa-5i 20: sa-532 21: sa-5312 22: sa-641 23: sa-642 24: sa-6400 25: sa-6400em 26: sa-6i 27: sa-generic 29: sa-p600 30: sa-p400 31: sa-e200 32: sa-e200i 33: sa-p400i 34: sa-p800 35: sa-e500 36: sa-p700m 37: sa-p212 38: sa-p410 39: sa-p410i 40: sa-p411 41: sa-b110i 42: sa-p712m 43: sa-p711m 44: sa-p812 45: sw-1210m 46: sa-p220i 47: sa-p222 48: sa-p420 49: sa-p420i 50: sa-p421 51: sa-b320i 52: sa-p822 53: sa-p721m 54: sa-b120i 55: hps-1224 56: hps-1228 57: hps-1228m 58: sa-p822se 59: hps-1224e 60: hps-1228e 61: hps-1228em 62: sa-p230i 63: sa-p430i 64: sa-p430 65: sa-p431 66: sa-p731m 67: sa-p830i 68: sa-p830 69: sa-p831 70: sa-p530 71: sa-p531 72: sa-p244br 73: sa-p246br 74: sa-p440 75: sa-p440ar 76: sa-p441 77: sa-p741m 78: sa-p840 79: sa-p841 80: sh-h240ar 81: sh-h244br 82: sh-h240 83: sh-h241 84: sa-b140i 85: sh-generic 86: sa-p240nr 87: sh-h240nr 88: sa-p840ar 89: sa-p542d 90: s100i 91: e208i-p 92: e208i-a 93: e208i-c 94: e208e-p 95: p204i-b 96: p204i-c 97: p408i-p 98: p408i-a 99: p408e-p 100: p408i-c 101: p408e-m 102: p416ie-m 103: p816i-a 104: p408i-sb - name: cpqDaCntlrFWRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.3 type: DisplayString help: Array Controller Firmware Revision - 1.3.6.1.4.1.232.3.2.2.1.1.3 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrStndIntr oid: 1.3.6.1.4.1.232.3.2.2.1.1.4 type: gauge help: The status of the Standard Interface - 1.3.6.1.4.1.232.3.2.2.1.1.4 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: primary 3: secondary 4: disabled 5: unavailable - name: cpqDaCntlrSlot oid: 1.3.6.1.4.1.232.3.2.2.1.1.5 type: gauge help: Array Controller Slot - 1.3.6.1.4.1.232.3.2.2.1.1.5 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrCondition oid: 1.3.6.1.4.1.232.3.2.2.1.1.6 type: gauge help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.6 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaCntlrProductRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.7 type: DisplayString help: Array Controller Product Revision - 1.3.6.1.4.1.232.3.2.2.1.1.7 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrPartnerSlot oid: 1.3.6.1.4.1.232.3.2.2.1.1.8 type: gauge help: Array Controller Partner Slot - 1.3.6.1.4.1.232.3.2.2.1.1.8 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrCurrentRole oid: 1.3.6.1.4.1.232.3.2.2.1.1.9 type: gauge help: Array Controller Current Role - 1.3.6.1.4.1.232.3.2.2.1.1.9 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notDuplexed 3: active 4: backup 5: asymActiveActive - name: cpqDaCntlrBoardStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.10 type: gauge help: Array Controller Board Status - 1.3.6.1.4.1.232.3.2.2.1.1.10 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: generalFailure 4: cableProblem 5: poweredOff 6: cacheModuleMissing - name: cpqDaCntlrPartnerBoardStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.11 type: gauge help: Array Controller Partner Board Status - 1.3.6.1.4.1.232.3.2.2.1.1.11 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: generalFailure 4: cableProblem 5: poweredOff - name: cpqDaCntlrBoardCondition oid: 1.3.6.1.4.1.232.3.2.2.1.1.12 type: gauge help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.12 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaCntlrPartnerBoardCondition oid: 1.3.6.1.4.1.232.3.2.2.1.1.13 type: gauge help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.13 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaCntlrDriveOwnership oid: 1.3.6.1.4.1.232.3.2.2.1.1.14 type: gauge help: Array Controller Drive Ownership - 1.3.6.1.4.1.232.3.2.2.1.1.14 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: owner 3: notOwner - name: cpqDaCntlrSerialNumber oid: 1.3.6.1.4.1.232.3.2.2.1.1.15 type: DisplayString help: Array Controller Serial Number - 1.3.6.1.4.1.232.3.2.2.1.1.15 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrRedundancyType oid: 1.3.6.1.4.1.232.3.2.2.1.1.16 type: gauge help: Array Controller Redundancy Type - 1.3.6.1.4.1.232.3.2.2.1.1.16 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notRedundant 3: driverDuplexing 4: fwActiveStandby 5: fwPrimarySecondary 6: fwActiveActive - name: cpqDaCntlrRedundancyError oid: 1.3.6.1.4.1.232.3.2.2.1.1.17 type: gauge help: Array Controller Redundancy Error - 1.3.6.1.4.1.232.3.2.2.1.1.17 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: noFailure 3: noRedundantController 4: differentHardware 5: noLink 6: differentFirmware 7: differentCache 8: otherCacheFailure 9: noDrives 10: otherNoDrives 11: unsupportedDrives 12: expandInProgress - name: cpqDaCntlrAccessModuleStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.18 type: gauge help: Array Controller RAID ADG Enabler Module Status - 1.3.6.1.4.1.232.3.2.2.1.1.18 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notSupported 3: notPresent 4: badSignature 5: badChecksum 6: fullyFunctional 7: upgradeFirmware - name: cpqDaCntlrDaughterBoardType oid: 1.3.6.1.4.1.232.3.2.2.1.1.19 type: gauge help: Array Controller Daughter Board Type - 1.3.6.1.4.1.232.3.2.2.1.1.19 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notSupported 3: notPresent 4: scsiBoardPresent 5: fibreBoardPresent 6: arrayExpansionModulePresent - name: cpqDaCntlrHwLocation oid: 1.3.6.1.4.1.232.3.2.2.1.1.20 type: DisplayString help: A text description of the hardware location of the controller - 1.3.6.1.4.1.232.3.2.2.1.1.20 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrNumberOfBuses oid: 1.3.6.1.4.1.232.3.2.2.1.1.21 type: gauge help: Array Controller Number of Buses - 1.3.6.1.4.1.232.3.2.2.1.1.21 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrBlinkTime oid: 1.3.6.1.4.1.232.3.2.2.1.1.22 type: counter help: Controller Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.2.1.1.22 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrRebuildPriority oid: 1.3.6.1.4.1.232.3.2.2.1.1.23 type: gauge help: Array Controller Rebuild Priority - 1.3.6.1.4.1.232.3.2.2.1.1.23 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: low 3: medium 4: high 5: mediumHigh - name: cpqDaCntlrExpandPriority oid: 1.3.6.1.4.1.232.3.2.2.1.1.24 type: gauge help: Array Controller Expand Priority - 1.3.6.1.4.1.232.3.2.2.1.1.24 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: low 3: medium 4: high - name: cpqDaCntlrNumberOfInternalPorts oid: 1.3.6.1.4.1.232.3.2.2.1.1.25 type: gauge help: Array Controller Number of Internal Ports - 1.3.6.1.4.1.232.3.2.2.1.1.25 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrNumberOfExternalPorts oid: 1.3.6.1.4.1.232.3.2.2.1.1.26 type: gauge help: Array Controller Number of External Ports - 1.3.6.1.4.1.232.3.2.2.1.1.26 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrDriveWriteCacheState oid: 1.3.6.1.4.1.232.3.2.2.1.1.27 type: gauge help: Array Controller Drive Write Cache State - 1.3.6.1.4.1.232.3.2.2.1.1.27 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: disabled 3: enabled - name: cpqDaCntlrPartnerSerialNumber oid: 1.3.6.1.4.1.232.3.2.2.1.1.28 type: DisplayString help: Array Controller Partner Serial Number - 1.3.6.1.4.1.232.3.2.2.1.1.28 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrOptionRomRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.29 type: DisplayString help: Array Controller Option ROM Revision - 1.3.6.1.4.1.232.3.2.2.1.1.29 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrHbaFWRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.30 type: DisplayString help: Array Controller HBA Firmware Revision - 1.3.6.1.4.1.232.3.2.2.1.1.30 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrHBAModeOptionRomRev oid: 1.3.6.1.4.1.232.3.2.2.1.1.31 type: DisplayString help: Array Controller HBA Mode Option Rom Revision - 1.3.6.1.4.1.232.3.2.2.1.1.31 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrCurrentTemp oid: 1.3.6.1.4.1.232.3.2.2.1.1.32 type: gauge help: Array Controller Current Temperature - 1.3.6.1.4.1.232.3.2.2.1.1.32 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrLastLockupCode oid: 1.3.6.1.4.1.232.3.2.2.1.1.33 type: gauge help: Array Controller Last Lockup Code - 1.3.6.1.4.1.232.3.2.2.1.1.33 indexes: - labelname: cpqDaCntlrIndex type: gauge - name: cpqDaCntlrEncryptionStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.34 type: gauge help: Array Controller Encryption Status - 1.3.6.1.4.1.232.3.2.2.1.1.34 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: notEnabled 3: enabledLocalKeyMode 4: enabledRemoteKeyManagerMode - name: cpqDaCntlrASICEncptSelfTestStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.35 type: gauge help: Array Controller ASIC Encryption Self Test Status - 1.3.6.1.4.1.232.3.2.2.1.1.35 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: selfTestsPass 3: selfTestsFailed - name: cpqDaCntlrEncryptCspNvramStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.36 type: gauge help: Array Controller Encryption Critical Security Parameter NVRAM Status - 1.3.6.1.4.1.232.3.2.2.1.1.36 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: ok 3: detectionFailed - name: cpqDaCntlrEncryptCryptoOfficerPwdSetStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.37 type: gauge help: Array Controller Encryption Crypto Officer Password Set Status - 1.3.6.1.4.1.232.3.2.2.1.1.37 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrEncryptCntlrPwdSetStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.38 type: gauge help: Array Controller Encryption Controller Password Set Status - 1.3.6.1.4.1.232.3.2.2.1.1.38 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrEncryptCntlrPwdAvailStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.39 type: gauge help: Array Controller Encryption Controller Password Availability Status - 1.3.6.1.4.1.232.3.2.2.1.1.39 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: passwordMissing 3: passwordActive - name: cpqDaCntlrUnencryptedLogDrvCreationPolicy oid: 1.3.6.1.4.1.232.3.2.2.1.1.40 type: gauge help: Array Controller Unencrypted Logical Drive Creation Policy - 1.3.6.1.4.1.232.3.2.2.1.1.40 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrEncryptedLogDrvCreationPolicy oid: 1.3.6.1.4.1.232.3.2.2.1.1.41 type: gauge help: Array Controller Encrypted Logical Drive Creation Policy - 1.3.6.1.4.1.232.3.2.2.1.1.41 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrEncryptFWLockStatus oid: 1.3.6.1.4.1.232.3.2.2.1.1.42 type: gauge help: Array Controller Encryption Firmware Lock Status - 1.3.6.1.4.1.232.3.2.2.1.1.42 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: "false" 3: "true" - name: cpqDaCntlrOperatingMode oid: 1.3.6.1.4.1.232.3.2.2.1.1.43 type: gauge help: Array Controller Operating Mode - 1.3.6.1.4.1.232.3.2.2.1.1.43 indexes: - labelname: cpqDaCntlrIndex type: gauge enum_values: 1: other 2: smartArrayMode 3: smartHbaMode 4: mixedMode - name: cpqDaLogDrvCntlrIndex oid: 1.3.6.1.4.1.232.3.2.3.1.1.1 type: gauge help: Drive Array Logical Drive Controller Index - 1.3.6.1.4.1.232.3.2.3.1.1.1 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvIndex oid: 1.3.6.1.4.1.232.3.2.3.1.1.2 type: gauge help: Drive Array Logical Drive Index - 1.3.6.1.4.1.232.3.2.3.1.1.2 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvFaultTol oid: 1.3.6.1.4.1.232.3.2.3.1.1.3 type: gauge help: Logical Drive Fault Tolerance - 1.3.6.1.4.1.232.3.2.3.1.1.3 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: none 3: mirroring 4: dataGuard 5: distribDataGuard 7: advancedDataGuard 8: raid50 9: raid60 10: raid1Adm 11: raid10Adm 12: raid10 - name: cpqDaLogDrvStatus oid: 1.3.6.1.4.1.232.3.2.3.1.1.4 type: gauge help: Logical Drive Status - 1.3.6.1.4.1.232.3.2.3.1.1.4 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: unconfigured 5: recovering 6: readyForRebuild 7: rebuilding 8: wrongDrive 9: badConnect 10: overheating 11: shutdown 12: expanding 13: notAvailable 14: queuedForExpansion 15: multipathAccessDegraded 16: erasing 17: predictiveSpareRebuildReady 18: rapidParityInitInProgress 19: rapidParityInitPending 20: noAccessEncryptedNoCntlrKey 21: unencryptedToEncryptedInProgress 22: newLogDrvKeyRekeyInProgress 23: noAccessEncryptedCntlrEncryptnNotEnbld 24: unencryptedToEncryptedNotStarted 25: newLogDrvKeyRekeyRequestReceived - name: cpqDaLogDrvAutoRel oid: 1.3.6.1.4.1.232.3.2.3.1.1.5 type: gauge help: Array Controller Logical Drive Auto-Reliability Delay - 1.3.6.1.4.1.232.3.2.3.1.1.5 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvRebuildBlks oid: 1.3.6.1.4.1.232.3.2.3.1.1.6 type: counter help: Logical Drive Rebuild Blocks Remaining - 1.3.6.1.4.1.232.3.2.3.1.1.6 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvHasAccel oid: 1.3.6.1.4.1.232.3.2.3.1.1.7 type: gauge help: Logical Drive Has Cache Module Board - 1.3.6.1.4.1.232.3.2.3.1.1.7 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: unavailable 3: enabled 4: disabled - name: cpqDaLogDrvAvailSpares oid: 1.3.6.1.4.1.232.3.2.3.1.1.8 type: OctetString help: Drive Array Logical Drive Available Spares - 1.3.6.1.4.1.232.3.2.3.1.1.8 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvSize oid: 1.3.6.1.4.1.232.3.2.3.1.1.9 type: gauge help: Logical Drive Size - 1.3.6.1.4.1.232.3.2.3.1.1.9 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvPhyDrvIDs oid: 1.3.6.1.4.1.232.3.2.3.1.1.10 type: OctetString help: Drive Array Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.3.2.3.1.1.10 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvCondition oid: 1.3.6.1.4.1.232.3.2.3.1.1.11 type: gauge help: The Logical Drive condition - 1.3.6.1.4.1.232.3.2.3.1.1.11 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaLogDrvPercentRebuild oid: 1.3.6.1.4.1.232.3.2.3.1.1.12 type: gauge help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.3.2.3.1.1.12 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvStripeSize oid: 1.3.6.1.4.1.232.3.2.3.1.1.13 type: gauge help: Logical Drive Stripe Size - 1.3.6.1.4.1.232.3.2.3.1.1.13 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvOsName oid: 1.3.6.1.4.1.232.3.2.3.1.1.14 type: DisplayString help: Logical Drive OS Name - 1.3.6.1.4.1.232.3.2.3.1.1.14 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvBlinkTime oid: 1.3.6.1.4.1.232.3.2.3.1.1.15 type: counter help: Logical Drive Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.3.1.1.15 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvSpareReplaceMap oid: 1.3.6.1.4.1.232.3.2.3.1.1.16 type: OctetString help: Logical Drive Spare To Replacement Drive Map - 1.3.6.1.4.1.232.3.2.3.1.1.16 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvRebuildingPhyDrv oid: 1.3.6.1.4.1.232.3.2.3.1.1.17 type: gauge help: Logical Drive Physical Drive Rebuilding Index - 1.3.6.1.4.1.232.3.2.3.1.1.17 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvMultipathAccess oid: 1.3.6.1.4.1.232.3.2.3.1.1.18 type: gauge help: Logical Drive Multi-path Access - 1.3.6.1.4.1.232.3.2.3.1.1.18 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: notSupported 3: notConfigured 4: pathRedundant 5: noRedundantPath - name: cpqDaLogDrvNmbrOfParityGroups oid: 1.3.6.1.4.1.232.3.2.3.1.1.19 type: gauge help: Logical Drive Number Of Parity Groups - 1.3.6.1.4.1.232.3.2.3.1.1.19 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvSplitMirrorBackupLogDrv oid: 1.3.6.1.4.1.232.3.2.3.1.1.20 type: gauge help: Logical Drive Split Mirror Backup Logical Drive - 1.3.6.1.4.1.232.3.2.3.1.1.20 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: isNotBackupLogicalDrive 3: isBackupLogicalDrive - name: cpqDaLogDrvCacheVolAccelAssocType oid: 1.3.6.1.4.1.232.3.2.3.1.1.21 type: gauge help: Logical Drive Cache Volume Accelerator Association Type - 1.3.6.1.4.1.232.3.2.3.1.1.21 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: nonMember 3: logicalDriveMember 4: cacheVolumeMember - name: cpqDaLogDrvCacheVolIndex oid: 1.3.6.1.4.1.232.3.2.3.1.1.22 type: gauge help: Logical Drive Cache Volume Index - 1.3.6.1.4.1.232.3.2.3.1.1.22 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvRPIPercentComplete oid: 1.3.6.1.4.1.232.3.2.3.1.1.23 type: gauge help: Logical Drive Rapid Parity Initialization Percent Complete - 1.3.6.1.4.1.232.3.2.3.1.1.23 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge - name: cpqDaLogDrvSSDSmartPathStatus oid: 1.3.6.1.4.1.232.3.2.3.1.1.24 type: gauge help: Logical Drive SSD Smart Path Status - 1.3.6.1.4.1.232.3.2.3.1.1.24 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: updateDriver 3: ssdSmartPathDisabled 4: ssdSmartPathEnabled - name: cpqDaLogDrvEncryptionStatus oid: 1.3.6.1.4.1.232.3.2.3.1.1.25 type: gauge help: Logical Drive Encryption Status - 1.3.6.1.4.1.232.3.2.3.1.1.25 indexes: - labelname: cpqDaLogDrvCntlrIndex type: gauge - labelname: cpqDaLogDrvIndex type: gauge enum_values: 1: other 2: encrypted 3: notEncrypted - name: cpqDaPhyDrvCntlrIndex oid: 1.3.6.1.4.1.232.3.2.5.1.1.1 type: gauge help: Drive Array Physical Drive Controller Index - 1.3.6.1.4.1.232.3.2.5.1.1.1 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvIndex oid: 1.3.6.1.4.1.232.3.2.5.1.1.2 type: gauge help: Drive Array Physical Drive Index - 1.3.6.1.4.1.232.3.2.5.1.1.2 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvModel oid: 1.3.6.1.4.1.232.3.2.5.1.1.3 type: DisplayString help: Physical Drive Model - 1.3.6.1.4.1.232.3.2.5.1.1.3 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFWRev oid: 1.3.6.1.4.1.232.3.2.5.1.1.4 type: DisplayString help: Physical Drive Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.4 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBay oid: 1.3.6.1.4.1.232.3.2.5.1.1.5 type: gauge help: Physical Drive Bay Location - 1.3.6.1.4.1.232.3.2.5.1.1.5 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.6 type: gauge help: Physical Drive Status - 1.3.6.1.4.1.232.3.2.5.1.1.6 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: predictiveFailure 5: erasing 6: eraseDone 7: eraseQueued 8: ssdWearOut 9: notAuthenticated - name: cpqDaPhyDrvFactReallocs oid: 1.3.6.1.4.1.232.3.2.5.1.1.7 type: gauge help: This shows the number of spare sectors available for remapping at the time the physical drive was shipped - 1.3.6.1.4.1.232.3.2.5.1.1.7 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvUsedReallocs oid: 1.3.6.1.4.1.232.3.2.5.1.1.8 type: counter help: Physical Drive Used Reallocated Sectors - 1.3.6.1.4.1.232.3.2.5.1.1.8 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvRefHours oid: 1.3.6.1.4.1.232.3.2.5.1.1.9 type: counter help: Reference Time in hours - 1.3.6.1.4.1.232.3.2.5.1.1.9 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHReads oid: 1.3.6.1.4.1.232.3.2.5.1.1.10 type: counter help: Sectors Read (high) - 1.3.6.1.4.1.232.3.2.5.1.1.10 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvReads oid: 1.3.6.1.4.1.232.3.2.5.1.1.11 type: counter help: Sectors Read (low) - 1.3.6.1.4.1.232.3.2.5.1.1.11 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHWrites oid: 1.3.6.1.4.1.232.3.2.5.1.1.12 type: counter help: Sectors Written (high) - 1.3.6.1.4.1.232.3.2.5.1.1.12 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvWrites oid: 1.3.6.1.4.1.232.3.2.5.1.1.13 type: counter help: Sectors Written (low) - 1.3.6.1.4.1.232.3.2.5.1.1.13 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHSeeks oid: 1.3.6.1.4.1.232.3.2.5.1.1.14 type: counter help: Total Seeks (high) - 1.3.6.1.4.1.232.3.2.5.1.1.14 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSeeks oid: 1.3.6.1.4.1.232.3.2.5.1.1.15 type: counter help: Total Seeks (low) - 1.3.6.1.4.1.232.3.2.5.1.1.15 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHardReadErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.16 type: counter help: Hard Read Errors - 1.3.6.1.4.1.232.3.2.5.1.1.16 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvRecvReadErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.17 type: counter help: Recovered Read Errors - 1.3.6.1.4.1.232.3.2.5.1.1.17 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHardWriteErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.18 type: counter help: Hard Write Errors - 1.3.6.1.4.1.232.3.2.5.1.1.18 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvRecvWriteErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.19 type: counter help: Recovered Write Errors - 1.3.6.1.4.1.232.3.2.5.1.1.19 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHSeekErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.20 type: counter help: Seek Errors (High) - 1.3.6.1.4.1.232.3.2.5.1.1.20 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSeekErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.21 type: counter help: Seek Errors (low) - 1.3.6.1.4.1.232.3.2.5.1.1.21 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSpinupTime oid: 1.3.6.1.4.1.232.3.2.5.1.1.22 type: gauge help: Spin up Time in tenths of seconds - 1.3.6.1.4.1.232.3.2.5.1.1.22 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFunctTest1 oid: 1.3.6.1.4.1.232.3.2.5.1.1.23 type: gauge help: Functional Test 1 - 1.3.6.1.4.1.232.3.2.5.1.1.23 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFunctTest2 oid: 1.3.6.1.4.1.232.3.2.5.1.1.24 type: gauge help: Functional Test 2 - 1.3.6.1.4.1.232.3.2.5.1.1.24 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFunctTest3 oid: 1.3.6.1.4.1.232.3.2.5.1.1.25 type: gauge help: Functional Test 3 - 1.3.6.1.4.1.232.3.2.5.1.1.25 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvDrqTimeouts oid: 1.3.6.1.4.1.232.3.2.5.1.1.26 type: counter help: DRQ Timeouts - 1.3.6.1.4.1.232.3.2.5.1.1.26 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvOtherTimeouts oid: 1.3.6.1.4.1.232.3.2.5.1.1.27 type: counter help: Other Timeouts - 1.3.6.1.4.1.232.3.2.5.1.1.27 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSpinupRetries oid: 1.3.6.1.4.1.232.3.2.5.1.1.28 type: counter help: Spin up Retries - 1.3.6.1.4.1.232.3.2.5.1.1.28 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBadRecvReads oid: 1.3.6.1.4.1.232.3.2.5.1.1.29 type: counter help: Recovery Failed (Bad) Read Error - 1.3.6.1.4.1.232.3.2.5.1.1.29 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBadRecvWrites oid: 1.3.6.1.4.1.232.3.2.5.1.1.30 type: counter help: Recovery Failed (Bad) Write Error - 1.3.6.1.4.1.232.3.2.5.1.1.30 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvFormatErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.31 type: counter help: Format Error - 1.3.6.1.4.1.232.3.2.5.1.1.31 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvPostErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.32 type: counter help: Power On Self Test (Post) Error - 1.3.6.1.4.1.232.3.2.5.1.1.32 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvNotReadyErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.33 type: counter help: Drive Not Ready Errors - 1.3.6.1.4.1.232.3.2.5.1.1.33 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvReallocAborts oid: 1.3.6.1.4.1.232.3.2.5.1.1.34 type: counter help: Physical Drive Reallocation Aborts - 1.3.6.1.4.1.232.3.2.5.1.1.34 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvThreshPassed oid: 1.3.6.1.4.1.232.3.2.5.1.1.35 type: gauge help: Physical Drive Factory Threshold Passed (Exceeded) - 1.3.6.1.4.1.232.3.2.5.1.1.35 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: "false" 2: "true" - name: cpqDaPhyDrvHasMonInfo oid: 1.3.6.1.4.1.232.3.2.5.1.1.36 type: gauge help: Physical Drive Has Monitor Information - 1.3.6.1.4.1.232.3.2.5.1.1.36 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: "false" 2: "true" - name: cpqDaPhyDrvCondition oid: 1.3.6.1.4.1.232.3.2.5.1.1.37 type: gauge help: The condition of the device - 1.3.6.1.4.1.232.3.2.5.1.1.37 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqDaPhyDrvHotPlugs oid: 1.3.6.1.4.1.232.3.2.5.1.1.38 type: counter help: Physical Drive Hot Plug Count - 1.3.6.1.4.1.232.3.2.5.1.1.38 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvMediaErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.39 type: counter help: Physical Drive Media Failure Count - 1.3.6.1.4.1.232.3.2.5.1.1.39 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHardwareErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.40 type: counter help: Physical Drive Hardware Error Count - 1.3.6.1.4.1.232.3.2.5.1.1.40 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvAbortedCmds oid: 1.3.6.1.4.1.232.3.2.5.1.1.41 type: counter help: Physical Drive Aborted Command Failures - 1.3.6.1.4.1.232.3.2.5.1.1.41 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSpinUpErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.42 type: counter help: Physical Drive Spin-Up Failure Count - 1.3.6.1.4.1.232.3.2.5.1.1.42 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBadTargetErrs oid: 1.3.6.1.4.1.232.3.2.5.1.1.43 type: counter help: Physical Drive Bad Target Count - 1.3.6.1.4.1.232.3.2.5.1.1.43 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvLocation oid: 1.3.6.1.4.1.232.3.2.5.1.1.44 type: gauge help: Drive Physical Location - 1.3.6.1.4.1.232.3.2.5.1.1.44 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: internal 3: external 4: proLiant - name: cpqDaPhyDrvSize oid: 1.3.6.1.4.1.232.3.2.5.1.1.45 type: gauge help: Physical Drive Size in MB - 1.3.6.1.4.1.232.3.2.5.1.1.45 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBusFaults oid: 1.3.6.1.4.1.232.3.2.5.1.1.46 type: counter help: Physical Drive Bus Fault Count - 1.3.6.1.4.1.232.3.2.5.1.1.46 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvIrqDeglitches oid: 1.3.6.1.4.1.232.3.2.5.1.1.47 type: counter help: Physical Drive IRQ Deglitch Count - 1.3.6.1.4.1.232.3.2.5.1.1.47 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvHotPlug oid: 1.3.6.1.4.1.232.3.2.5.1.1.48 type: gauge help: Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.3.2.5.1.1.48 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: hotPlug 3: nonHotPlug - name: cpqDaPhyDrvPlacement oid: 1.3.6.1.4.1.232.3.2.5.1.1.49 type: gauge help: Physical Drive Placement - 1.3.6.1.4.1.232.3.2.5.1.1.49 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: internal 3: external - name: cpqDaPhyDrvBusNumber oid: 1.3.6.1.4.1.232.3.2.5.1.1.50 type: gauge help: Physical Drive SCSI Bus Number - 1.3.6.1.4.1.232.3.2.5.1.1.50 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSerialNum oid: 1.3.6.1.4.1.232.3.2.5.1.1.51 type: DisplayString help: Physical Drive Serial Number - 1.3.6.1.4.1.232.3.2.5.1.1.51 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvPreFailMonitoring oid: 1.3.6.1.4.1.232.3.2.5.1.1.52 type: gauge help: Drive Array Physical Drive Predictive Failure Monitoring - 1.3.6.1.4.1.232.3.2.5.1.1.52 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: notAvailable 3: available - name: cpqDaPhyDrvCurrentWidth oid: 1.3.6.1.4.1.232.3.2.5.1.1.53 type: gauge help: Drive Array Physical Drive Current Width - 1.3.6.1.4.1.232.3.2.5.1.1.53 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: narrow 3: wide16 - name: cpqDaPhyDrvCurrentSpeed oid: 1.3.6.1.4.1.232.3.2.5.1.1.54 type: gauge help: Drive Array Physical Drive Current Data Transfer Speed - 1.3.6.1.4.1.232.3.2.5.1.1.54 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: asynchronous 3: fast 4: ultra 5: ultra2 6: ultra3 7: ultra320 - name: cpqDaPhyDrvFailureCode oid: 1.3.6.1.4.1.232.3.2.5.1.1.55 type: gauge help: Drive Array Physical Drive Failure Code - 1.3.6.1.4.1.232.3.2.5.1.1.55 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBlinkTime oid: 1.3.6.1.4.1.232.3.2.5.1.1.56 type: counter help: Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.5.1.1.56 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSmartStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.57 type: gauge help: Physical Drive S.M.A.R.T Status - 1.3.6.1.4.1.232.3.2.5.1.1.57 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: replaceDrive 4: replaceDriveSSDWearOut - name: cpqDaPhyDrvConfigurationStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.58 type: gauge help: Physical Drive Configuration Status - 1.3.6.1.4.1.232.3.2.5.1.1.58 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: configured 3: notConfigured - name: cpqDaPhyDrvRotationalSpeed oid: 1.3.6.1.4.1.232.3.2.5.1.1.59 type: gauge help: Drive Array Physical Drive Rotational Speed - 1.3.6.1.4.1.232.3.2.5.1.1.59 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: rpm7200 3: rpm10K 4: rpm15K 5: rpmSsd - name: cpqDaPhyDrvType oid: 1.3.6.1.4.1.232.3.2.5.1.1.60 type: gauge help: Physical Drive Type - 1.3.6.1.4.1.232.3.2.5.1.1.60 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: parallelScsi 3: sata 4: sas - name: cpqDaPhyDrvSataVersion oid: 1.3.6.1.4.1.232.3.2.5.1.1.61 type: gauge help: Physical Drive SATA Version - 1.3.6.1.4.1.232.3.2.5.1.1.61 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: sataOne 3: sataTwo - name: cpqDaPhyDrvHostConnector oid: 1.3.6.1.4.1.232.3.2.5.1.1.62 type: DisplayString help: Physical Drive Host Connector - 1.3.6.1.4.1.232.3.2.5.1.1.62 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvBoxOnConnector oid: 1.3.6.1.4.1.232.3.2.5.1.1.63 type: gauge help: Physical Drive Box on Connector - 1.3.6.1.4.1.232.3.2.5.1.1.63 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvLocationString oid: 1.3.6.1.4.1.232.3.2.5.1.1.64 type: DisplayString help: Physical Drive Location String - 1.3.6.1.4.1.232.3.2.5.1.1.64 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvNegotiatedLinkRate oid: 1.3.6.1.4.1.232.3.2.5.1.1.65 type: gauge help: Drive Array Physical Drive Negotiated Link Rate - 1.3.6.1.4.1.232.3.2.5.1.1.65 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: rate-1-5 3: rate-3-0 4: rate-6-0 5: rate-12-0 - name: cpqDaPhyDrvNcqSupport oid: 1.3.6.1.4.1.232.3.2.5.1.1.66 type: gauge help: Drive Array Physical Drive Native Command Queueing - 1.3.6.1.4.1.232.3.2.5.1.1.66 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: noControllerSupport 3: noDriveSupport 4: ncqDisabled 5: ncqEnabled - name: cpqDaPhyDrvPhyCount oid: 1.3.6.1.4.1.232.3.2.5.1.1.67 type: gauge help: Drive Array Physical Drive PHY Count - 1.3.6.1.4.1.232.3.2.5.1.1.67 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvMultipathAccess oid: 1.3.6.1.4.1.232.3.2.5.1.1.68 type: gauge help: Drive Array Physical Drive Multi-path Access Status - 1.3.6.1.4.1.232.3.2.5.1.1.68 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: notSupported 3: notConfigured 4: pathRedundant 5: noRedundantPath 6: driveFailed - name: cpqDaPhyDrvMediaType oid: 1.3.6.1.4.1.232.3.2.5.1.1.69 type: gauge help: Drive Array Physical Drive Media Type - 1.3.6.1.4.1.232.3.2.5.1.1.69 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: rotatingPlatters 3: solidState 4: smr - name: cpqDaPhyDrvCurrentTemperature oid: 1.3.6.1.4.1.232.3.2.5.1.1.70 type: gauge help: Drive Array Physical Drive Current Temperature - 1.3.6.1.4.1.232.3.2.5.1.1.70 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvTemperatureThreshold oid: 1.3.6.1.4.1.232.3.2.5.1.1.71 type: gauge help: Drive Array Physical Drive Temperature Threshold - 1.3.6.1.4.1.232.3.2.5.1.1.71 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvMaximumTemperature oid: 1.3.6.1.4.1.232.3.2.5.1.1.72 type: gauge help: Drive Array Physical Drive Maximum Temperature - 1.3.6.1.4.1.232.3.2.5.1.1.72 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSSDWearStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.73 type: gauge help: Drive Array Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.3.2.5.1.1.73 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: fiftySixDayThreshold 4: fivePercentThreshold 5: twoPercentThreshold 6: ssdWearOut - name: cpqDaPhyDrvPowerOnHours oid: 1.3.6.1.4.1.232.3.2.5.1.1.74 type: counter help: Drive Array Physical Drive Power On Hours - 1.3.6.1.4.1.232.3.2.5.1.1.74 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSSDPercntEndrnceUsed oid: 1.3.6.1.4.1.232.3.2.5.1.1.75 type: gauge help: Drive Array Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.3.2.5.1.1.75 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSSDEstTimeRemainingHours oid: 1.3.6.1.4.1.232.3.2.5.1.1.76 type: counter help: Drive Array Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.3.2.5.1.1.76 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvAuthenticationStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.77 type: gauge help: Drive Array Physical Drive Authentication Status - 1.3.6.1.4.1.232.3.2.5.1.1.77 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: notSupported 3: authenticationFailed 4: authenticationPassed - name: cpqDaPhyDrvSmartCarrierAppFWRev oid: 1.3.6.1.4.1.232.3.2.5.1.1.78 type: gauge help: Physical Drive Smart Carrier Application Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.78 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvSmartCarrierBootldrFWRev oid: 1.3.6.1.4.1.232.3.2.5.1.1.79 type: gauge help: Physical Drive Smart Carrier Bootloader Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.79 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge - name: cpqDaPhyDrvEncryptionStatus oid: 1.3.6.1.4.1.232.3.2.5.1.1.80 type: gauge help: Physical Drive Encryption Status - 1.3.6.1.4.1.232.3.2.5.1.1.80 indexes: - labelname: cpqDaPhyDrvCntlrIndex type: gauge - labelname: cpqDaPhyDrvIndex type: gauge enum_values: 1: other 2: encrypted 3: notEncrypted - name: cpqScsiMibRevMajor oid: 1.3.6.1.4.1.232.5.1.1 type: gauge help: The Major Revision level - 1.3.6.1.4.1.232.5.1.1 - name: cpqScsiMibRevMinor oid: 1.3.6.1.4.1.232.5.1.2 type: gauge help: The Minor Revision level - 1.3.6.1.4.1.232.5.1.2 - name: cpqScsiMibCondition oid: 1.3.6.1.4.1.232.5.1.3 type: gauge help: The overall condition - 1.3.6.1.4.1.232.5.1.3 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqScsiNw3xDriverName oid: 1.3.6.1.4.1.232.5.2.1.1.1 type: DisplayString help: SCSI Drive Device Driver Name - 1.3.6.1.4.1.232.5.2.1.1.1 - name: cpqScsiNw3xDriverVers oid: 1.3.6.1.4.1.232.5.2.1.1.2 type: DisplayString help: SCSI Drive Device Driver Version - 1.3.6.1.4.1.232.5.2.1.1.2 - name: cpqScsiNw3xDriverPollType oid: 1.3.6.1.4.1.232.5.2.1.1.3 type: gauge help: SCSI Drive Device Driver Poll Type - 1.3.6.1.4.1.232.5.2.1.1.3 enum_values: 1: other 2: polled 3: demand - name: cpqScsiNw3xDriverPollTime oid: 1.3.6.1.4.1.232.5.2.1.1.4 type: gauge help: SCSI Drive Device Driver Poll Time - 1.3.6.1.4.1.232.5.2.1.1.4 - name: cpqScsiNw3xCntlrIndex oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.1 type: gauge help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.1.1.5.1.1 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xBusIndex oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.2 type: gauge help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.5.1.2 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xXptDesc oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.3 type: DisplayString help: SCSI XPT Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.3 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xXptVers oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.4 type: DisplayString help: SCSI XPT Version - 1.3.6.1.4.1.232.5.2.1.1.5.1.4 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xSimDesc oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.5 type: DisplayString help: SCSI SIM Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.5 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xSimVers oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.6 type: DisplayString help: SCSI SIM Version - 1.3.6.1.4.1.232.5.2.1.1.5.1.6 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xHbaDesc oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.7 type: DisplayString help: SCSI HBA Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.7 indexes: - labelname: cpqScsiNw3xCntlrIndex type: gauge - labelname: cpqScsiNw3xBusIndex type: gauge - name: cpqScsiNw3xStatCntlrIndex oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.1 type: gauge help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.1 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xStatBusIndex oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.2 type: gauge help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.2 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xStatLogDrvIndex oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.3 type: gauge help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.3 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xTotalReads oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.4 type: counter help: SCSI Logical Drive Total Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.4 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xTotalWrites oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.5 type: counter help: SCSI Logical Drive Total Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.5 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xCorrReads oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.6 type: counter help: SCSI Logical Drive Corrected Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.6 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xCorrWrites oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.7 type: counter help: SCSI Logical Drive Corrected Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.7 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xFatalReads oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.8 type: counter help: SCSI Logical Drive Fatal Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.8 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xFatalWrites oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.9 type: counter help: SCSI Logical Drive Fatal Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.9 indexes: - labelname: cpqScsiNw3xStatCntlrIndex type: gauge - labelname: cpqScsiNw3xStatBusIndex type: gauge - labelname: cpqScsiNw3xStatLogDrvIndex type: gauge - name: cpqScsiNw3xVolCntlrIndex oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.1 type: gauge help: SCSI Cntlr Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.1 indexes: - labelname: cpqScsiNw3xVolCntlrIndex type: gauge - labelname: cpqScsiNw3xVolBusIndex type: gauge - labelname: cpqScsiNw3xVolLogDrvIndex type: gauge - name: cpqScsiNw3xVolBusIndex oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.2 type: gauge help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.2 indexes: - labelname: cpqScsiNw3xVolCntlrIndex type: gauge - labelname: cpqScsiNw3xVolBusIndex type: gauge - labelname: cpqScsiNw3xVolLogDrvIndex type: gauge - name: cpqScsiNw3xVolLogDrvIndex oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.3 type: gauge help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.3 indexes: - labelname: cpqScsiNw3xVolCntlrIndex type: gauge - labelname: cpqScsiNw3xVolBusIndex type: gauge - labelname: cpqScsiNw3xVolLogDrvIndex type: gauge - name: cpqScsiNw3xVolMap oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.4 type: OctetString help: SCSI Drive Volume Map - 1.3.6.1.4.1.232.5.2.1.1.7.1.4 indexes: - labelname: cpqScsiNw3xVolCntlrIndex type: gauge - labelname: cpqScsiNw3xVolBusIndex type: gauge - labelname: cpqScsiNw3xVolLogDrvIndex type: gauge - name: cpqScsiOsCommonPollFreq oid: 1.3.6.1.4.1.232.5.2.1.4.1 type: gauge help: The agent`s polling frequency - 1.3.6.1.4.1.232.5.2.1.4.1 - name: cpqScsiOsCommonModuleIndex oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.1 type: gauge help: A unique index for this module description. - 1.3.6.1.4.1.232.5.2.1.4.2.1.1 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiOsCommonModuleName oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.2 type: DisplayString help: The module name. - 1.3.6.1.4.1.232.5.2.1.4.2.1.2 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiOsCommonModuleVersion oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.3 type: DisplayString help: The module version in XX.YY format - 1.3.6.1.4.1.232.5.2.1.4.2.1.3 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiOsCommonModuleDate oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.4 type: OctetString help: The module date - 1.3.6.1.4.1.232.5.2.1.4.2.1.4 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiOsCommonModulePurpose oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.5 type: DisplayString help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.5.2.1.4.2.1.5 indexes: - labelname: cpqScsiOsCommonModuleIndex type: gauge - name: cpqScsiCntlrIndex oid: 1.3.6.1.4.1.232.5.2.2.1.1.1 type: gauge help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.2.1.1.1 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrBusIndex oid: 1.3.6.1.4.1.232.5.2.2.1.1.2 type: gauge help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.2.1.1.2 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrModel oid: 1.3.6.1.4.1.232.5.2.2.1.1.3 type: gauge help: SCSI Controller Model - 1.3.6.1.4.1.232.5.2.2.1.1.3 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge enum_values: 1: other 2: cpqs710 3: cpqs94 4: cpqs810p 5: cpqs825e 6: cpqs825p 7: cpqs974p 8: cpqs875p 9: extended 10: cpqs895p 11: cpqs896p 12: cpqa789x 13: cpqs876t 14: hpu320 15: hpu320r 16: generic 17: hp1u320g2 18: hp1u320g1 19: hpSc11Xe - name: cpqScsiCntlrFWVers oid: 1.3.6.1.4.1.232.5.2.2.1.1.4 type: DisplayString help: SCSI Controller Firmware Version - 1.3.6.1.4.1.232.5.2.2.1.1.4 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrSWVers oid: 1.3.6.1.4.1.232.5.2.2.1.1.5 type: DisplayString help: SCSI Controller Software Version - 1.3.6.1.4.1.232.5.2.2.1.1.5 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrSlot oid: 1.3.6.1.4.1.232.5.2.2.1.1.6 type: gauge help: SCSI Controller Slot - 1.3.6.1.4.1.232.5.2.2.1.1.6 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrStatus oid: 1.3.6.1.4.1.232.5.2.2.1.1.7 type: gauge help: SCSI Controller Status - 1.3.6.1.4.1.232.5.2.2.1.1.7 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge enum_values: 1: other 2: ok 3: failed - name: cpqScsiCntlrHardResets oid: 1.3.6.1.4.1.232.5.2.2.1.1.8 type: counter help: SCSI Controller Hard Resets - 1.3.6.1.4.1.232.5.2.2.1.1.8 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrSoftResets oid: 1.3.6.1.4.1.232.5.2.2.1.1.9 type: counter help: SCSI Controller Soft Resets - 1.3.6.1.4.1.232.5.2.2.1.1.9 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrTimeouts oid: 1.3.6.1.4.1.232.5.2.2.1.1.10 type: counter help: SCSI Controller Time-outs - 1.3.6.1.4.1.232.5.2.2.1.1.10 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrBaseIOAddr oid: 1.3.6.1.4.1.232.5.2.2.1.1.11 type: gauge help: SCSI Controller Base I/O Address - 1.3.6.1.4.1.232.5.2.2.1.1.11 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrCondition oid: 1.3.6.1.4.1.232.5.2.2.1.1.12 type: gauge help: SCSI Controller Condition - 1.3.6.1.4.1.232.5.2.2.1.1.12 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqScsiCntlrSerialNum oid: 1.3.6.1.4.1.232.5.2.2.1.1.13 type: DisplayString help: SCSI Controller Serial Number - 1.3.6.1.4.1.232.5.2.2.1.1.13 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrBusWidth oid: 1.3.6.1.4.1.232.5.2.2.1.1.14 type: gauge help: SCSI Controller Data Bus Width - 1.3.6.1.4.1.232.5.2.2.1.1.14 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge enum_values: 1: other 2: narrow 3: wide16 - name: cpqScsiCntlrModelExtended oid: 1.3.6.1.4.1.232.5.2.2.1.1.15 type: DisplayString help: SCSI Controller Model Name - 1.3.6.1.4.1.232.5.2.2.1.1.15 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrHwLocation oid: 1.3.6.1.4.1.232.5.2.2.1.1.16 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the SCSI controller - 1.3.6.1.4.1.232.5.2.2.1.1.16 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiCntlrPciLocation oid: 1.3.6.1.4.1.232.5.2.2.1.1.17 type: DisplayString help: A string designating the PCI device location for the controller, following the format DDDD:BB:DD.F, where DDDD is the PCI domain number, BB is the PCI bus number, DD is the PCI device number, and F is the PCI function number - 1.3.6.1.4.1.232.5.2.2.1.1.17 indexes: - labelname: cpqScsiCntlrIndex type: gauge - labelname: cpqScsiCntlrBusIndex type: gauge - name: cpqScsiLogDrvCntlrIndex oid: 1.3.6.1.4.1.232.5.2.3.1.1.1 type: gauge help: SCSI Logical Drive Controller Index - 1.3.6.1.4.1.232.5.2.3.1.1.1 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvBusIndex oid: 1.3.6.1.4.1.232.5.2.3.1.1.2 type: gauge help: SCSI Logical Drive Bus Index - 1.3.6.1.4.1.232.5.2.3.1.1.2 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvIndex oid: 1.3.6.1.4.1.232.5.2.3.1.1.3 type: gauge help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.3.1.1.3 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvFaultTol oid: 1.3.6.1.4.1.232.5.2.3.1.1.4 type: gauge help: SCSI Logical Drive Fault Tolerance - 1.3.6.1.4.1.232.5.2.3.1.1.4 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge enum_values: 1: other 2: none 3: mirroring 4: dataGuard 5: distribDataGuard 6: enhancedMirroring - name: cpqScsiLogDrvStatus oid: 1.3.6.1.4.1.232.5.2.3.1.1.5 type: gauge help: SCSI Logical Drive Status - 1.3.6.1.4.1.232.5.2.3.1.1.5 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: unconfigured 5: recovering 6: readyForRebuild 7: rebuilding 8: wrongDrive 9: badConnect 10: degraded 11: disabled - name: cpqScsiLogDrvSize oid: 1.3.6.1.4.1.232.5.2.3.1.1.6 type: gauge help: SCSI Logical Drive Size - 1.3.6.1.4.1.232.5.2.3.1.1.6 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvPhyDrvIDs oid: 1.3.6.1.4.1.232.5.2.3.1.1.7 type: OctetString help: SCSI Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.5.2.3.1.1.7 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvCondition oid: 1.3.6.1.4.1.232.5.2.3.1.1.8 type: gauge help: SCSI Logical Drive Condition - 1.3.6.1.4.1.232.5.2.3.1.1.8 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqScsiLogDrvStripeSize oid: 1.3.6.1.4.1.232.5.2.3.1.1.9 type: gauge help: Logical Drive Stripe Size - 1.3.6.1.4.1.232.5.2.3.1.1.9 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvAvailSpares oid: 1.3.6.1.4.1.232.5.2.3.1.1.10 type: OctetString help: SCSI Logical Drive Available Spares - 1.3.6.1.4.1.232.5.2.3.1.1.10 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvPercentRebuild oid: 1.3.6.1.4.1.232.5.2.3.1.1.11 type: gauge help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.5.2.3.1.1.11 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiLogDrvOsName oid: 1.3.6.1.4.1.232.5.2.3.1.1.12 type: DisplayString help: Logical Drive OS Name - 1.3.6.1.4.1.232.5.2.3.1.1.12 indexes: - labelname: cpqScsiLogDrvCntlrIndex type: gauge - labelname: cpqScsiLogDrvBusIndex type: gauge - labelname: cpqScsiLogDrvIndex type: gauge - name: cpqScsiPhyDrvCntlrIndex oid: 1.3.6.1.4.1.232.5.2.4.1.1.1 type: gauge help: SCSI Physical Drive Controller Index - 1.3.6.1.4.1.232.5.2.4.1.1.1 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvBusIndex oid: 1.3.6.1.4.1.232.5.2.4.1.1.2 type: gauge help: SCSI Physical Drive Bus Index - 1.3.6.1.4.1.232.5.2.4.1.1.2 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvIndex oid: 1.3.6.1.4.1.232.5.2.4.1.1.3 type: gauge help: SCSI Physical Drive Index - 1.3.6.1.4.1.232.5.2.4.1.1.3 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvModel oid: 1.3.6.1.4.1.232.5.2.4.1.1.4 type: DisplayString help: SCSI Physical Drive Model - 1.3.6.1.4.1.232.5.2.4.1.1.4 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvFWRev oid: 1.3.6.1.4.1.232.5.2.4.1.1.5 type: DisplayString help: SCSI Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.2.4.1.1.5 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvVendor oid: 1.3.6.1.4.1.232.5.2.4.1.1.6 type: DisplayString help: SCSI Physical Drive Vendor - 1.3.6.1.4.1.232.5.2.4.1.1.6 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvSize oid: 1.3.6.1.4.1.232.5.2.4.1.1.7 type: gauge help: SCSI Physical Drive Size in MB - 1.3.6.1.4.1.232.5.2.4.1.1.7 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvScsiID oid: 1.3.6.1.4.1.232.5.2.4.1.1.8 type: gauge help: SCSI Physical Drive SCSI ID - 1.3.6.1.4.1.232.5.2.4.1.1.8 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvStatus oid: 1.3.6.1.4.1.232.5.2.4.1.1.9 type: gauge help: SCSI Physical Drive Status - 1.3.6.1.4.1.232.5.2.4.1.1.9 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: notConfigured 5: badCable 6: missingWasOk 7: missingWasFailed 8: predictiveFailure 9: missingWasPredictiveFailure 10: offline 11: missingWasOffline 12: hardError - name: cpqScsiPhyDrvServiceHours oid: 1.3.6.1.4.1.232.5.2.4.1.1.10 type: counter help: SCSI Physical Drive Service Time in hours - 1.3.6.1.4.1.232.5.2.4.1.1.10 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHighReadSectors oid: 1.3.6.1.4.1.232.5.2.4.1.1.11 type: counter help: SCSI Physical Drive Sectors Read (high) - 1.3.6.1.4.1.232.5.2.4.1.1.11 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvLowReadSectors oid: 1.3.6.1.4.1.232.5.2.4.1.1.12 type: counter help: SCSI Physical Drive Sectors Read (low) - 1.3.6.1.4.1.232.5.2.4.1.1.12 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHighWriteSectors oid: 1.3.6.1.4.1.232.5.2.4.1.1.13 type: counter help: SCSI Physical Drive Sectors Written (high) - 1.3.6.1.4.1.232.5.2.4.1.1.13 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvLowWriteSectors oid: 1.3.6.1.4.1.232.5.2.4.1.1.14 type: counter help: SCSI Physical Drive Sectors Written (low) - 1.3.6.1.4.1.232.5.2.4.1.1.14 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHardReadErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.15 type: counter help: SCSI Physical Drive Hard Read Errors - 1.3.6.1.4.1.232.5.2.4.1.1.15 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHardWriteErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.16 type: counter help: SCSI Physical Drive Hard Write Errors - 1.3.6.1.4.1.232.5.2.4.1.1.16 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvEccCorrReads oid: 1.3.6.1.4.1.232.5.2.4.1.1.17 type: counter help: SCSI Physical Drive ECC Corrected Read Errors (high) - 1.3.6.1.4.1.232.5.2.4.1.1.17 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvRecvReadErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.18 type: counter help: SCSI Physical Drive Recovered Read Errors - 1.3.6.1.4.1.232.5.2.4.1.1.18 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvRecvWriteErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.19 type: counter help: SCSI Physical Drive Recovered Write Errors - 1.3.6.1.4.1.232.5.2.4.1.1.19 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvSeekErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.20 type: counter help: SCSI Physical Drive Seek Errors - 1.3.6.1.4.1.232.5.2.4.1.1.20 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvSpinupTime oid: 1.3.6.1.4.1.232.5.2.4.1.1.21 type: gauge help: SCSI Physical Drive Spin up Time (tenths of seconds) - 1.3.6.1.4.1.232.5.2.4.1.1.21 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvUsedReallocs oid: 1.3.6.1.4.1.232.5.2.4.1.1.22 type: counter help: SCSI Physical Drive Used Reallocation Sectors - 1.3.6.1.4.1.232.5.2.4.1.1.22 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvTimeouts oid: 1.3.6.1.4.1.232.5.2.4.1.1.23 type: counter help: SCSI Physical Drive Time-out Errors - 1.3.6.1.4.1.232.5.2.4.1.1.23 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvPostErrs oid: 1.3.6.1.4.1.232.5.2.4.1.1.24 type: counter help: SCSI Physical Drive Power On Self Test (POST) Errors - 1.3.6.1.4.1.232.5.2.4.1.1.24 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvPostErrCode oid: 1.3.6.1.4.1.232.5.2.4.1.1.25 type: gauge help: SCSI Physical Drive Last POST Error Code - 1.3.6.1.4.1.232.5.2.4.1.1.25 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvCondition oid: 1.3.6.1.4.1.232.5.2.4.1.1.26 type: gauge help: SCSI Physical Drive Condition - 1.3.6.1.4.1.232.5.2.4.1.1.26 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqScsiPhyDrvFuncTest1 oid: 1.3.6.1.4.1.232.5.2.4.1.1.27 type: gauge help: SCSI Physical Drive Functional Test 1 - 1.3.6.1.4.1.232.5.2.4.1.1.27 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvFuncTest2 oid: 1.3.6.1.4.1.232.5.2.4.1.1.28 type: gauge help: SCSI Physical Drive Functional Test 2 - 1.3.6.1.4.1.232.5.2.4.1.1.28 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvStatsPreserved oid: 1.3.6.1.4.1.232.5.2.4.1.1.29 type: gauge help: SCSI Physical Drive Statistics Preservation Method - 1.3.6.1.4.1.232.5.2.4.1.1.29 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: inNVRAM 3: onDisk 4: noCPUSupport 5: noFreeNVRAM 6: noDrvSupport 7: noSoftwareSupport 8: statsNotSupported - name: cpqScsiPhyDrvSerialNum oid: 1.3.6.1.4.1.232.5.2.4.1.1.30 type: DisplayString help: SCSI Physical Drive Serial Number - 1.3.6.1.4.1.232.5.2.4.1.1.30 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvLocation oid: 1.3.6.1.4.1.232.5.2.4.1.1.31 type: gauge help: SCSI Physical Drive Location - 1.3.6.1.4.1.232.5.2.4.1.1.31 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: proliant - name: cpqScsiPhyDrvParent oid: 1.3.6.1.4.1.232.5.2.4.1.1.32 type: gauge help: SCSI Physical Drive Parent - 1.3.6.1.4.1.232.5.2.4.1.1.32 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvSectorSize oid: 1.3.6.1.4.1.232.5.2.4.1.1.33 type: gauge help: SCSI Physical Drive Sector Size in Bytes - 1.3.6.1.4.1.232.5.2.4.1.1.33 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvHotPlug oid: 1.3.6.1.4.1.232.5.2.4.1.1.34 type: gauge help: SCSI Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.2.4.1.1.34 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: hotPlug 3: nonHotPlug - name: cpqScsiPhyDrvPlacement oid: 1.3.6.1.4.1.232.5.2.4.1.1.35 type: gauge help: SCSI Physical Drive Placement - 1.3.6.1.4.1.232.5.2.4.1.1.35 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: internal 3: external - name: cpqScsiPhyDrvPreFailMonitoring oid: 1.3.6.1.4.1.232.5.2.4.1.1.36 type: gauge help: SCSI Physical Drive Predictive Failure Monitoring - 1.3.6.1.4.1.232.5.2.4.1.1.36 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: notAvailable 3: available - name: cpqScsiPhyDrvOsName oid: 1.3.6.1.4.1.232.5.2.4.1.1.37 type: DisplayString help: Physical Drive OS Name - 1.3.6.1.4.1.232.5.2.4.1.1.37 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge - name: cpqScsiPhyDrvRotationalSpeed oid: 1.3.6.1.4.1.232.5.2.4.1.1.38 type: gauge help: SCSI Physical Drive Rotational Speed - 1.3.6.1.4.1.232.5.2.4.1.1.38 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: rpm7200 3: rpm10K 4: rpm15K - name: cpqScsiPhyDrvMemberLogDrv oid: 1.3.6.1.4.1.232.5.2.4.1.1.39 type: gauge help: The Physical Drive is a Member of a Logical Drive - 1.3.6.1.4.1.232.5.2.4.1.1.39 indexes: - labelname: cpqScsiPhyDrvCntlrIndex type: gauge - labelname: cpqScsiPhyDrvBusIndex type: gauge - labelname: cpqScsiPhyDrvIndex type: gauge enum_values: 1: other 2: member 3: spare 4: nonMember - name: cpqScsiTargetCntlrIndex oid: 1.3.6.1.4.1.232.5.2.5.1.1.1 type: gauge help: SCSI Target Controller Index - 1.3.6.1.4.1.232.5.2.5.1.1.1 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetBusIndex oid: 1.3.6.1.4.1.232.5.2.5.1.1.2 type: gauge help: SCSI Target Bus Index - 1.3.6.1.4.1.232.5.2.5.1.1.2 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetScsiIdIndex oid: 1.3.6.1.4.1.232.5.2.5.1.1.3 type: gauge help: SCSI Target Device Index - 1.3.6.1.4.1.232.5.2.5.1.1.3 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetType oid: 1.3.6.1.4.1.232.5.2.5.1.1.4 type: gauge help: SCSI Device Type - 1.3.6.1.4.1.232.5.2.5.1.1.4 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: disk 3: tape 4: printer 5: processor 6: wormDrive 7: cd-rom 8: scanner 9: optical 10: jukeBox 11: commDev - name: cpqScsiTargetModel oid: 1.3.6.1.4.1.232.5.2.5.1.1.5 type: DisplayString help: SCSI Device Model - 1.3.6.1.4.1.232.5.2.5.1.1.5 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetFWRev oid: 1.3.6.1.4.1.232.5.2.5.1.1.6 type: DisplayString help: SCSI Device Firmware Revision - 1.3.6.1.4.1.232.5.2.5.1.1.6 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetVendor oid: 1.3.6.1.4.1.232.5.2.5.1.1.7 type: DisplayString help: SCSI Device Vendor - 1.3.6.1.4.1.232.5.2.5.1.1.7 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetParityErrs oid: 1.3.6.1.4.1.232.5.2.5.1.1.8 type: counter help: SCSI Device Bus Parity Errors - 1.3.6.1.4.1.232.5.2.5.1.1.8 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetPhaseErrs oid: 1.3.6.1.4.1.232.5.2.5.1.1.9 type: counter help: SCSI Device Bus Phase Errors - 1.3.6.1.4.1.232.5.2.5.1.1.9 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetSelectTimeouts oid: 1.3.6.1.4.1.232.5.2.5.1.1.10 type: counter help: SCSI Device Bus Select Time-outs - 1.3.6.1.4.1.232.5.2.5.1.1.10 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetMsgRejects oid: 1.3.6.1.4.1.232.5.2.5.1.1.11 type: counter help: SCSI Device Bus Message Rejects - 1.3.6.1.4.1.232.5.2.5.1.1.11 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetNegPeriod oid: 1.3.6.1.4.1.232.5.2.5.1.1.12 type: gauge help: SCSI Device Negotiated Period - 1.3.6.1.4.1.232.5.2.5.1.1.12 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetLocation oid: 1.3.6.1.4.1.232.5.2.5.1.1.13 type: gauge help: SCSI Device Location - 1.3.6.1.4.1.232.5.2.5.1.1.13 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: proliant - name: cpqScsiTargetNegSpeed oid: 1.3.6.1.4.1.232.5.2.5.1.1.14 type: gauge help: SCSI Device Negotiated Speed - 1.3.6.1.4.1.232.5.2.5.1.1.14 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetPhysWidth oid: 1.3.6.1.4.1.232.5.2.5.1.1.15 type: gauge help: SCSI Device Data Bus Physical Width - 1.3.6.1.4.1.232.5.2.5.1.1.15 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: narrow 3: wide16 - name: cpqScsiTargetNegWidth oid: 1.3.6.1.4.1.232.5.2.5.1.1.16 type: gauge help: SCSI Device Data Bus Negotiated Width - 1.3.6.1.4.1.232.5.2.5.1.1.16 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge - name: cpqScsiTargetTypeExtended oid: 1.3.6.1.4.1.232.5.2.5.1.1.17 type: gauge help: SCSI Extended Device Type - 1.3.6.1.4.1.232.5.2.5.1.1.17 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: pdcd 3: removableDisk 4: dltAutoloader 5: cdJukebox 6: cr3500 7: autoloader - name: cpqScsiTargetCurrentSpeed oid: 1.3.6.1.4.1.232.5.2.5.1.1.18 type: gauge help: SCSI Device Current Data Transfer Speed - 1.3.6.1.4.1.232.5.2.5.1.1.18 indexes: - labelname: cpqScsiTargetCntlrIndex type: gauge - labelname: cpqScsiTargetBusIndex type: gauge - labelname: cpqScsiTargetScsiIdIndex type: gauge enum_values: 1: other 2: asynchronous 3: fast 4: ultra 5: ultra2 6: ultra3 7: scsi1 8: ultra4 - name: cpqScsiCdDrvCntlrIndex oid: 1.3.6.1.4.1.232.5.2.6.1.1.1 type: gauge help: SCSI CD-ROM Drive Controller Index - 1.3.6.1.4.1.232.5.2.6.1.1.1 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvBusIndex oid: 1.3.6.1.4.1.232.5.2.6.1.1.2 type: gauge help: SCSI CD-ROM Drive Bus Index - 1.3.6.1.4.1.232.5.2.6.1.1.2 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvScsiIdIndex oid: 1.3.6.1.4.1.232.5.2.6.1.1.3 type: gauge help: SCSI CD-ROM Drive Index - 1.3.6.1.4.1.232.5.2.6.1.1.3 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvLunIndex oid: 1.3.6.1.4.1.232.5.2.6.1.1.4 type: gauge help: SCSI CD-ROM Drive Logical Unit Index - 1.3.6.1.4.1.232.5.2.6.1.1.4 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvModel oid: 1.3.6.1.4.1.232.5.2.6.1.1.5 type: DisplayString help: SCSI CD Device Model - 1.3.6.1.4.1.232.5.2.6.1.1.5 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvVendor oid: 1.3.6.1.4.1.232.5.2.6.1.1.6 type: DisplayString help: SCSI CD Drive Vendor - 1.3.6.1.4.1.232.5.2.6.1.1.6 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqScsiCdDrvFwRev oid: 1.3.6.1.4.1.232.5.2.6.1.1.7 type: DisplayString help: SCSI CD-ROM Firmware Revision - 1.3.6.1.4.1.232.5.2.6.1.1.7 indexes: - labelname: cpqScsiCdDrvCntlrIndex type: gauge - labelname: cpqScsiCdDrvBusIndex type: gauge - labelname: cpqScsiCdDrvScsiIdIndex type: gauge - labelname: cpqScsiCdDrvLunIndex type: gauge - name: cpqCdLibraryCntlrIndex oid: 1.3.6.1.4.1.232.5.2.6.2.1.1 type: gauge help: SCSI CD Library Controller Index - 1.3.6.1.4.1.232.5.2.6.2.1.1 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryBusIndex oid: 1.3.6.1.4.1.232.5.2.6.2.1.2 type: gauge help: SCSI CD Library Bus Index - 1.3.6.1.4.1.232.5.2.6.2.1.2 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryScsiIdIndex oid: 1.3.6.1.4.1.232.5.2.6.2.1.3 type: gauge help: SCSI CD Library Device Index - 1.3.6.1.4.1.232.5.2.6.2.1.3 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryLunIndex oid: 1.3.6.1.4.1.232.5.2.6.2.1.4 type: gauge help: SCSI CD Library Logical Unit Index - 1.3.6.1.4.1.232.5.2.6.2.1.4 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryCondition oid: 1.3.6.1.4.1.232.5.2.6.2.1.5 type: gauge help: CD Library Condition - 1.3.6.1.4.1.232.5.2.6.2.1.5 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqCdLibraryStatus oid: 1.3.6.1.4.1.232.5.2.6.2.1.6 type: gauge help: CD Library Status - 1.3.6.1.4.1.232.5.2.6.2.1.6 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge enum_values: 1: other 2: ok 3: failed 4: offline - name: cpqCdLibraryModel oid: 1.3.6.1.4.1.232.5.2.6.2.1.7 type: DisplayString help: SCSI CD Library Device Model - 1.3.6.1.4.1.232.5.2.6.2.1.7 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryVendor oid: 1.3.6.1.4.1.232.5.2.6.2.1.8 type: DisplayString help: SCSI CD Library Vendor - 1.3.6.1.4.1.232.5.2.6.2.1.8 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibrarySerialNumber oid: 1.3.6.1.4.1.232.5.2.6.2.1.9 type: DisplayString help: CD Library Serial Number - 1.3.6.1.4.1.232.5.2.6.2.1.9 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryDriveList oid: 1.3.6.1.4.1.232.5.2.6.2.1.10 type: OctetString help: CD Library Drive List This is a data structure containing the list of CD drive ids that are present in this library - 1.3.6.1.4.1.232.5.2.6.2.1.10 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryFwRev oid: 1.3.6.1.4.1.232.5.2.6.2.1.11 type: DisplayString help: SCSI CD Library Firmware Revision - 1.3.6.1.4.1.232.5.2.6.2.1.11 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqCdLibraryFwSubtype oid: 1.3.6.1.4.1.232.5.2.6.2.1.12 type: gauge help: SCSI CD library Firmware Subtype - 1.3.6.1.4.1.232.5.2.6.2.1.12 indexes: - labelname: cpqCdLibraryCntlrIndex type: gauge - labelname: cpqCdLibraryBusIndex type: gauge - labelname: cpqCdLibraryScsiIdIndex type: gauge - labelname: cpqCdLibraryLunIndex type: gauge - name: cpqScsiTrapPkts oid: 1.3.6.1.4.1.232.5.3.1 type: counter help: The total number of trap packets issued by the SCSI enterprise since the instrument agent was loaded. - 1.3.6.1.4.1.232.5.3.1 - name: cpqScsiTrapLogMaxSize oid: 1.3.6.1.4.1.232.5.3.2 type: gauge help: The maximum number of entries that will currently be kept in the trap log - 1.3.6.1.4.1.232.5.3.2 - name: cpqScsiTrapLogIndex oid: 1.3.6.1.4.1.232.5.3.3.1.1 type: gauge help: The value of this object uniquely identifies this trapLogEntry at this time - 1.3.6.1.4.1.232.5.3.3.1.1 indexes: - labelname: cpqScsiTrapLogIndex type: gauge - name: cpqScsiTrapType oid: 1.3.6.1.4.1.232.5.3.3.1.2 type: gauge help: The type of the trap event that this entry describes - 1.3.6.1.4.1.232.5.3.3.1.2 indexes: - labelname: cpqScsiTrapLogIndex type: gauge enum_values: 1: cpqScsiCntlrStatusChange 2: cpqScsiLogDrvStatusChange 3: cpqScsiPhyDrvStatusChange 5001: cpqScsi2CntlrStatusChange 5002: cpqScsi2LogDrvStatusChange 5003: cpqScsi2PhyDrvStatusChange - name: cpqScsiTrapTime oid: 1.3.6.1.4.1.232.5.3.3.1.3 type: OctetString help: The time of the trap event that this entry describes - 1.3.6.1.4.1.232.5.3.3.1.3 indexes: - labelname: cpqScsiTrapLogIndex type: gauge - name: cpqTapePhyDrvCntlrIndex oid: 1.3.6.1.4.1.232.5.4.1.1.1.1 type: gauge help: Tape Physical Drive Controller Index - 1.3.6.1.4.1.232.5.4.1.1.1.1 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvBusIndex oid: 1.3.6.1.4.1.232.5.4.1.1.1.2 type: gauge help: Tape Physical Drive Bus Index - 1.3.6.1.4.1.232.5.4.1.1.1.2 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvScsiIdIndex oid: 1.3.6.1.4.1.232.5.4.1.1.1.3 type: gauge help: Tape Physical Drive Index - 1.3.6.1.4.1.232.5.4.1.1.1.3 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvLunIndex oid: 1.3.6.1.4.1.232.5.4.1.1.1.4 type: gauge help: Tape Physical Drive Logical Unit Index - 1.3.6.1.4.1.232.5.4.1.1.1.4 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvType oid: 1.3.6.1.4.1.232.5.4.1.1.1.5 type: gauge help: Tape Device Type - 1.3.6.1.4.1.232.5.4.1.1.1.5 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: cpqDat4-16 3: cpqDatAuto 4: cpqDat2-8 5: cpqDlt10-20 6: cpqDlt20-40 7: cpqDlt15-30 8: cpqDlt35-70 9: cpqDat4-8 10: cpqSlr4-8 11: cpqDat12-24 12: cpqDatAuto12-24 13: cpqMlr16-32 14: cpqAit35 15: cpqAit50 16: cpqDat20-40 17: cpqDlt40-80 18: cpqDatAuto20-40 19: cpqSuperDlt1 20: cpqAit35Lvd 21: cpqCompaq - name: cpqTapePhyDrvCondition oid: 1.3.6.1.4.1.232.5.4.1.1.1.6 type: gauge help: Tape Physical Drive Status - 1.3.6.1.4.1.232.5.4.1.1.1.6 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqTapePhyDrvMagSize oid: 1.3.6.1.4.1.232.5.4.1.1.1.7 type: gauge help: Tape Physical Drive Magazine Size - 1.3.6.1.4.1.232.5.4.1.1.1.7 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvSerialNumber oid: 1.3.6.1.4.1.232.5.4.1.1.1.8 type: DisplayString help: Tape Physical Drive Serial Number - 1.3.6.1.4.1.232.5.4.1.1.1.8 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvCleanReq oid: 1.3.6.1.4.1.232.5.4.1.1.1.9 type: gauge help: Tape Physical Drive Cleaning Required Status - 1.3.6.1.4.1.232.5.4.1.1.1.9 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqTapePhyDrvCleanTapeRepl oid: 1.3.6.1.4.1.232.5.4.1.1.1.10 type: gauge help: Tape Physical Drive Cleaning Tape Replacement Status - 1.3.6.1.4.1.232.5.4.1.1.1.10 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqTapePhyDrvFwSubtype oid: 1.3.6.1.4.1.232.5.4.1.1.1.11 type: gauge help: Tape Physical Drive Firmware Subtype - 1.3.6.1.4.1.232.5.4.1.1.1.11 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvName oid: 1.3.6.1.4.1.232.5.4.1.1.1.12 type: DisplayString help: Tape Physical Drive Name - 1.3.6.1.4.1.232.5.4.1.1.1.12 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvCleanTapeCount oid: 1.3.6.1.4.1.232.5.4.1.1.1.13 type: gauge help: Tape Physical Drive Cleaning Tape Count - 1.3.6.1.4.1.232.5.4.1.1.1.13 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvFwRev oid: 1.3.6.1.4.1.232.5.4.1.1.1.14 type: DisplayString help: Tape Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.4.1.1.1.14 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvStatus oid: 1.3.6.1.4.1.232.5.4.1.1.1.15 type: gauge help: Tape Physical Drive Status - 1.3.6.1.4.1.232.5.4.1.1.1.15 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: ok 4: failed 5: offline 6: missingWasOk 7: missingWasFailed 8: missingWasOffline - name: cpqTapePhyDrvHotPlug oid: 1.3.6.1.4.1.232.5.4.1.1.1.16 type: gauge help: Tape Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.4.1.1.1.16 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: hotPlug 3: nonHotPlug - name: cpqTapePhyDrvPlacement oid: 1.3.6.1.4.1.232.5.4.1.1.1.17 type: gauge help: Tape Physical Drive Placement - 1.3.6.1.4.1.232.5.4.1.1.1.17 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: internal 3: external - name: cpqTapePhyDrvLibraryDrive oid: 1.3.6.1.4.1.232.5.4.1.1.1.18 type: gauge help: Tape Physical Drive Library Drive - 1.3.6.1.4.1.232.5.4.1.1.1.18 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge enum_values: 1: other 2: "true" 3: "false" - name: cpqTapePhyDrvLoaderName oid: 1.3.6.1.4.1.232.5.4.1.1.1.19 type: DisplayString help: Tape Autoloader Name - 1.3.6.1.4.1.232.5.4.1.1.1.19 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvLoaderFwRev oid: 1.3.6.1.4.1.232.5.4.1.1.1.20 type: DisplayString help: Tape Autoloader Firmware Revision - 1.3.6.1.4.1.232.5.4.1.1.1.20 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapePhyDrvLoaderSerialNum oid: 1.3.6.1.4.1.232.5.4.1.1.1.21 type: DisplayString help: Tape Autoloader Serial Number - 1.3.6.1.4.1.232.5.4.1.1.1.21 indexes: - labelname: cpqTapePhyDrvCntlrIndex type: gauge - labelname: cpqTapePhyDrvBusIndex type: gauge - labelname: cpqTapePhyDrvScsiIdIndex type: gauge - labelname: cpqTapePhyDrvLunIndex type: gauge - name: cpqTapeCountersCntlrIndex oid: 1.3.6.1.4.1.232.5.4.2.1.1.1 type: gauge help: SCSI Counters Controller Index - 1.3.6.1.4.1.232.5.4.2.1.1.1 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersBusIndex oid: 1.3.6.1.4.1.232.5.4.2.1.1.2 type: gauge help: SCSI Counters Bus Index - 1.3.6.1.4.1.232.5.4.2.1.1.2 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersScsiIdIndex oid: 1.3.6.1.4.1.232.5.4.2.1.1.3 type: gauge help: SCSI Counters Device Index - 1.3.6.1.4.1.232.5.4.2.1.1.3 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersLunIndex oid: 1.3.6.1.4.1.232.5.4.2.1.1.4 type: gauge help: SCSI Counters Logical Unit Index - 1.3.6.1.4.1.232.5.4.2.1.1.4 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersReWrites oid: 1.3.6.1.4.1.232.5.4.2.1.1.5 type: counter help: Tape Device Re-write count - 1.3.6.1.4.1.232.5.4.2.1.1.5 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersReReads oid: 1.3.6.1.4.1.232.5.4.2.1.1.6 type: counter help: Tape Device Re-read count - 1.3.6.1.4.1.232.5.4.2.1.1.6 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersTotalErrors oid: 1.3.6.1.4.1.232.5.4.2.1.1.7 type: counter help: Tape Device Total Errors - 1.3.6.1.4.1.232.5.4.2.1.1.7 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersTotalUncorrectable oid: 1.3.6.1.4.1.232.5.4.2.1.1.8 type: counter help: Tape Device Total Uncorrectable Errors - 1.3.6.1.4.1.232.5.4.2.1.1.8 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeCountersTotalBytes oid: 1.3.6.1.4.1.232.5.4.2.1.1.9 type: counter help: Tape Device Total Bytes - 1.3.6.1.4.1.232.5.4.2.1.1.9 indexes: - labelname: cpqTapeCountersCntlrIndex type: gauge - labelname: cpqTapeCountersBusIndex type: gauge - labelname: cpqTapeCountersScsiIdIndex type: gauge - labelname: cpqTapeCountersLunIndex type: gauge - name: cpqTapeLibraryCntlrIndex oid: 1.3.6.1.4.1.232.5.4.3.1.1.1 type: gauge help: SCSI Library Controller Index - 1.3.6.1.4.1.232.5.4.3.1.1.1 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryBusIndex oid: 1.3.6.1.4.1.232.5.4.3.1.1.2 type: gauge help: SCSI Library Bus Index - 1.3.6.1.4.1.232.5.4.3.1.1.2 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryScsiIdIndex oid: 1.3.6.1.4.1.232.5.4.3.1.1.3 type: gauge help: SCSI Library Device Index - 1.3.6.1.4.1.232.5.4.3.1.1.3 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryLunIndex oid: 1.3.6.1.4.1.232.5.4.3.1.1.4 type: gauge help: SCSI Library Logical Unit Index - 1.3.6.1.4.1.232.5.4.3.1.1.4 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryCondition oid: 1.3.6.1.4.1.232.5.4.3.1.1.5 type: gauge help: Tape Library Status - 1.3.6.1.4.1.232.5.4.3.1.1.5 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqTapeLibraryStatus oid: 1.3.6.1.4.1.232.5.4.3.1.1.6 type: gauge help: Error code returned by the last library error. - 1.3.6.1.4.1.232.5.4.3.1.1.6 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryDoorStatus oid: 1.3.6.1.4.1.232.5.4.3.1.1.7 type: gauge help: Status of the library door - 1.3.6.1.4.1.232.5.4.3.1.1.7 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: closed 3: open 4: notSupported - name: cpqTapeLibraryStatHours oid: 1.3.6.1.4.1.232.5.4.3.1.1.8 type: counter help: The number of hours of operation for the library. - 1.3.6.1.4.1.232.5.4.3.1.1.8 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryStatMoves oid: 1.3.6.1.4.1.232.5.4.3.1.1.9 type: counter help: The number of tape moves for the library loader arm. - 1.3.6.1.4.1.232.5.4.3.1.1.9 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryName oid: 1.3.6.1.4.1.232.5.4.3.1.1.10 type: DisplayString help: Tape Library Name. - 1.3.6.1.4.1.232.5.4.3.1.1.10 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibrarySerialNumber oid: 1.3.6.1.4.1.232.5.4.3.1.1.11 type: DisplayString help: Tape Library Serial Number - 1.3.6.1.4.1.232.5.4.3.1.1.11 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryDriveList oid: 1.3.6.1.4.1.232.5.4.3.1.1.12 type: OctetString help: Tape Library Drive List This is a data structure containing the list of tape drive ids that are present in this library - 1.3.6.1.4.1.232.5.4.3.1.1.12 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryState oid: 1.3.6.1.4.1.232.5.4.3.1.1.13 type: gauge help: Tape Library Status - 1.3.6.1.4.1.232.5.4.3.1.1.13 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed 5: offline - name: cpqTapeLibraryTemperature oid: 1.3.6.1.4.1.232.5.4.3.1.1.14 type: gauge help: Tape Library Temperature Status - 1.3.6.1.4.1.232.5.4.3.1.1.14 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: notSupported 3: ok 4: safeTempExceeded 5: maxTempExceeded - name: cpqTapeLibraryRedundancy oid: 1.3.6.1.4.1.232.5.4.3.1.1.15 type: gauge help: Tape Library Redundancy Status - 1.3.6.1.4.1.232.5.4.3.1.1.15 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: notSupported 3: capable 4: notCapable 5: active - name: cpqTapeLibraryHotSwap oid: 1.3.6.1.4.1.232.5.4.3.1.1.16 type: gauge help: Tape Library Hot Swap Status - 1.3.6.1.4.1.232.5.4.3.1.1.16 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge enum_values: 1: other 2: notSupported 3: capable 4: notCapable - name: cpqTapeLibraryFwRev oid: 1.3.6.1.4.1.232.5.4.3.1.1.17 type: DisplayString help: Tape Library Firmware Revision - 1.3.6.1.4.1.232.5.4.3.1.1.17 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqTapeLibraryTapeList oid: 1.3.6.1.4.1.232.5.4.3.1.1.18 type: OctetString help: Tape Library Drive List This is a data structure containing the list of tape drive ids that are present in this library - 1.3.6.1.4.1.232.5.4.3.1.1.18 indexes: - labelname: cpqTapeLibraryCntlrIndex type: gauge - labelname: cpqTapeLibraryBusIndex type: gauge - labelname: cpqTapeLibraryScsiIdIndex type: gauge - labelname: cpqTapeLibraryLunIndex type: gauge - name: cpqSasHbaIndex oid: 1.3.6.1.4.1.232.5.5.1.1.1.1 type: gauge help: SAS Host Bus Adapter Index - 1.3.6.1.4.1.232.5.5.1.1.1.1 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaHwLocation oid: 1.3.6.1.4.1.232.5.5.1.1.1.2 type: DisplayString help: SAS Host Bus Adapter Hardware Location - 1.3.6.1.4.1.232.5.5.1.1.1.2 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaModel oid: 1.3.6.1.4.1.232.5.5.1.1.1.3 type: gauge help: SAS Host Bus Adapter Model - 1.3.6.1.4.1.232.5.5.1.1.1.3 indexes: - labelname: cpqSasHbaIndex type: gauge enum_values: 1: other 2: generic 3: sas8int 4: sas4int 5: sasSc44Ge 6: sasSc40Ge 7: sasSc08Ge 8: sasSc08e 9: sasH220i 10: sasH221 11: sasH210i 12: sasH220 13: sasH222 14: sasP824ip - name: cpqSasHbaStatus oid: 1.3.6.1.4.1.232.5.5.1.1.1.4 type: gauge help: SAS Host Bus Adapter Status - 1.3.6.1.4.1.232.5.5.1.1.1.4 indexes: - labelname: cpqSasHbaIndex type: gauge enum_values: 1: other 2: ok 3: failed - name: cpqSasHbaCondition oid: 1.3.6.1.4.1.232.5.5.1.1.1.5 type: gauge help: SAS Host Bus Adapter Condition - 1.3.6.1.4.1.232.5.5.1.1.1.5 indexes: - labelname: cpqSasHbaIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasHbaOverallCondition oid: 1.3.6.1.4.1.232.5.5.1.1.1.6 type: gauge help: SAS Host Bus Adapter Overall Condition - 1.3.6.1.4.1.232.5.5.1.1.1.6 indexes: - labelname: cpqSasHbaIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasHbaSerialNumber oid: 1.3.6.1.4.1.232.5.5.1.1.1.7 type: DisplayString help: SAS Host Bus Adapter Serial Number - 1.3.6.1.4.1.232.5.5.1.1.1.7 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaFwVersion oid: 1.3.6.1.4.1.232.5.5.1.1.1.8 type: DisplayString help: SAS Host Bus Adapter Firmware Version - 1.3.6.1.4.1.232.5.5.1.1.1.8 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaBiosVersion oid: 1.3.6.1.4.1.232.5.5.1.1.1.9 type: DisplayString help: SAS Host Bus Adapter BIOS Version - 1.3.6.1.4.1.232.5.5.1.1.1.9 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasHbaPciLocation oid: 1.3.6.1.4.1.232.5.5.1.1.1.10 type: DisplayString help: SAS Host Bus Adapter PCI Location - 1.3.6.1.4.1.232.5.5.1.1.1.10 indexes: - labelname: cpqSasHbaIndex type: gauge - name: cpqSasPhyDrvHbaIndex oid: 1.3.6.1.4.1.232.5.5.2.1.1.1 type: gauge help: SAS Physical Drive HBA Index - 1.3.6.1.4.1.232.5.5.2.1.1.1 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvIndex oid: 1.3.6.1.4.1.232.5.5.2.1.1.2 type: gauge help: SAS Physical Drive Index - 1.3.6.1.4.1.232.5.5.2.1.1.2 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvLocationString oid: 1.3.6.1.4.1.232.5.5.2.1.1.3 type: DisplayString help: SAS Physical Drive Location String - 1.3.6.1.4.1.232.5.5.2.1.1.3 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvModel oid: 1.3.6.1.4.1.232.5.5.2.1.1.4 type: DisplayString help: SAS Physical Drive Model - 1.3.6.1.4.1.232.5.5.2.1.1.4 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvStatus oid: 1.3.6.1.4.1.232.5.5.2.1.1.5 type: gauge help: SAS Physical Drive Status - 1.3.6.1.4.1.232.5.5.2.1.1.5 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: predictiveFailure 4: offline 5: failed 6: missingWasOk 7: missingWasPredictiveFailure 8: missingWasOffline 9: missingWasFailed 10: ssdWearOut 11: missingWasSSDWearOut 12: notAuthenticated 13: missingWasNotAuthenticated - name: cpqSasPhyDrvCondition oid: 1.3.6.1.4.1.232.5.5.2.1.1.6 type: gauge help: SAS Physical Drive Condition - 1.3.6.1.4.1.232.5.5.2.1.1.6 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasPhyDrvFWRev oid: 1.3.6.1.4.1.232.5.5.2.1.1.7 type: DisplayString help: SAS Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.7 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSize oid: 1.3.6.1.4.1.232.5.5.2.1.1.8 type: gauge help: SAS Physical Drive Size in MB - 1.3.6.1.4.1.232.5.5.2.1.1.8 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvUsedReallocs oid: 1.3.6.1.4.1.232.5.5.2.1.1.9 type: counter help: SAS Physical Drive Used Reallocation Sectors - 1.3.6.1.4.1.232.5.5.2.1.1.9 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSerialNumber oid: 1.3.6.1.4.1.232.5.5.2.1.1.10 type: DisplayString help: SAS Physical Drive Serial Number - 1.3.6.1.4.1.232.5.5.2.1.1.10 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvMemberLogDrv oid: 1.3.6.1.4.1.232.5.5.2.1.1.11 type: gauge help: The Physical Drive is a Member of a Logical Drive - 1.3.6.1.4.1.232.5.5.2.1.1.11 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: member 3: spare 4: nonMember - name: cpqSasPhyDrvRotationalSpeed oid: 1.3.6.1.4.1.232.5.5.2.1.1.12 type: gauge help: SAS Physical Drive Rotational Speed - 1.3.6.1.4.1.232.5.5.2.1.1.12 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: rpm7200 3: rpm10K 4: rpm15K 5: rpmSsd - name: cpqSasPhyDrvOsName oid: 1.3.6.1.4.1.232.5.5.2.1.1.13 type: DisplayString help: SAS Physical Drive OS Name - 1.3.6.1.4.1.232.5.5.2.1.1.13 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvPlacement oid: 1.3.6.1.4.1.232.5.5.2.1.1.14 type: gauge help: SAS Physical Drive Placement - 1.3.6.1.4.1.232.5.5.2.1.1.14 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: internal 3: external - name: cpqSasPhyDrvHotPlug oid: 1.3.6.1.4.1.232.5.5.2.1.1.15 type: gauge help: SAS Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.5.2.1.1.15 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: hotPlug 3: nonHotPlug - name: cpqSasPhyDrvType oid: 1.3.6.1.4.1.232.5.5.2.1.1.16 type: gauge help: SAS Physical Drive Type - 1.3.6.1.4.1.232.5.5.2.1.1.16 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: sas 3: sata - name: cpqSasPhyDrvSasAddress oid: 1.3.6.1.4.1.232.5.5.2.1.1.17 type: DisplayString help: SAS Physical Drive SAS Address - 1.3.6.1.4.1.232.5.5.2.1.1.17 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvMediaType oid: 1.3.6.1.4.1.232.5.5.2.1.1.18 type: gauge help: SAS Physical Drive Media Type - 1.3.6.1.4.1.232.5.5.2.1.1.18 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: rotatingPlatters 3: solidState - name: cpqSasPhyDrvSSDWearStatus oid: 1.3.6.1.4.1.232.5.5.2.1.1.19 type: gauge help: SAS Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.5.5.2.1.1.19 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: ok 3: fiftySixDayThreshold 4: fivePercentThreshold 5: twoPercentThreshold 6: ssdWearOut - name: cpqSasPhyDrvPowerOnHours oid: 1.3.6.1.4.1.232.5.5.2.1.1.20 type: counter help: SAS Physical Drive Power On Hours - 1.3.6.1.4.1.232.5.5.2.1.1.20 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSSDPercntEndrnceUsed oid: 1.3.6.1.4.1.232.5.5.2.1.1.21 type: gauge help: SAS Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.5.5.2.1.1.21 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSSDEstTimeRemainingHours oid: 1.3.6.1.4.1.232.5.5.2.1.1.22 type: counter help: SAS Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.5.5.2.1.1.22 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvAuthenticationStatus oid: 1.3.6.1.4.1.232.5.5.2.1.1.23 type: gauge help: SAS Physical Drive Authentication Status - 1.3.6.1.4.1.232.5.5.2.1.1.23 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge enum_values: 1: other 2: notSupported 3: authenticationFailed 4: authenticationPassed - name: cpqSasPhyDrvSmartCarrierAppFWRev oid: 1.3.6.1.4.1.232.5.5.2.1.1.24 type: gauge help: SAS Physical Drive Smart Carrier Application Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.24 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSmartCarrierBootldrFWRev oid: 1.3.6.1.4.1.232.5.5.2.1.1.25 type: gauge help: SAS Physical Drive Smart Carrier Bootloader Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.25 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvCurrTemperature oid: 1.3.6.1.4.1.232.5.5.2.1.1.26 type: gauge help: SAS Physical Drive Current Operating Temperature degrees Celsius - 1.3.6.1.4.1.232.5.5.2.1.1.26 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvTemperatureThreshold oid: 1.3.6.1.4.1.232.5.5.2.1.1.27 type: gauge help: SAS Physical Drive Maximum Operating Temperature in degrees Celsius - 1.3.6.1.4.1.232.5.5.2.1.1.27 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSsBoxModel oid: 1.3.6.1.4.1.232.5.5.2.1.1.28 type: DisplayString help: SAS Physical Drive Box Model - 1.3.6.1.4.1.232.5.5.2.1.1.28 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSsBoxFwRev oid: 1.3.6.1.4.1.232.5.5.2.1.1.29 type: DisplayString help: SAS Physical Drive Box Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.29 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSsBoxVendor oid: 1.3.6.1.4.1.232.5.5.2.1.1.30 type: DisplayString help: SAS Physical Drive Box Vendor This is the SAS drive box`s vendor name - 1.3.6.1.4.1.232.5.5.2.1.1.30 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasPhyDrvSsBoxSerialNumber oid: 1.3.6.1.4.1.232.5.5.2.1.1.31 type: DisplayString help: SAS Physical Drive Box Serial Number - 1.3.6.1.4.1.232.5.5.2.1.1.31 indexes: - labelname: cpqSasPhyDrvHbaIndex type: gauge - labelname: cpqSasPhyDrvIndex type: gauge - name: cpqSasLogDrvHbaIndex oid: 1.3.6.1.4.1.232.5.5.3.1.1.1 type: gauge help: SAS Logical Drive HBA Index - 1.3.6.1.4.1.232.5.5.3.1.1.1 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvIndex oid: 1.3.6.1.4.1.232.5.5.3.1.1.2 type: gauge help: SAS Logical Drive Index - 1.3.6.1.4.1.232.5.5.3.1.1.2 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvRaidLevel oid: 1.3.6.1.4.1.232.5.5.3.1.1.3 type: gauge help: SAS Logical Drive RAID Level - 1.3.6.1.4.1.232.5.5.3.1.1.3 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge enum_values: 1: other 2: raid0 3: raid1 4: raid0plus1 5: raid5 6: raid15 7: volume - name: cpqSasLogDrvStatus oid: 1.3.6.1.4.1.232.5.5.3.1.1.4 type: gauge help: SAS Logical Drive Status - 1.3.6.1.4.1.232.5.5.3.1.1.4 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: rebuilding 5: failed 6: offline - name: cpqSasLogDrvCondition oid: 1.3.6.1.4.1.232.5.5.3.1.1.5 type: gauge help: SAS Logical Drive Condition - 1.3.6.1.4.1.232.5.5.3.1.1.5 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasLogDrvRebuildingDisk oid: 1.3.6.1.4.1.232.5.5.3.1.1.6 type: gauge help: SAS Logical Drive Rebuilding Disk - 1.3.6.1.4.1.232.5.5.3.1.1.6 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvCapacity oid: 1.3.6.1.4.1.232.5.5.3.1.1.7 type: gauge help: SAS Logical Drive Size - 1.3.6.1.4.1.232.5.5.3.1.1.7 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvStripeSize oid: 1.3.6.1.4.1.232.5.5.3.1.1.8 type: gauge help: SAS Logical Drive Stripe Size - 1.3.6.1.4.1.232.5.5.3.1.1.8 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvPhyDrvIds oid: 1.3.6.1.4.1.232.5.5.3.1.1.9 type: OctetString help: SAS Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.5.5.3.1.1.9 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvSpareIds oid: 1.3.6.1.4.1.232.5.5.3.1.1.10 type: OctetString help: SAS Logical Drive Spare Drive IDs - 1.3.6.1.4.1.232.5.5.3.1.1.10 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvOsName oid: 1.3.6.1.4.1.232.5.5.3.1.1.11 type: DisplayString help: SAS Logical Drive OS Name - 1.3.6.1.4.1.232.5.5.3.1.1.11 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasLogDrvRebuildingPercent oid: 1.3.6.1.4.1.232.5.5.3.1.1.12 type: gauge help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.5.5.3.1.1.12 indexes: - labelname: cpqSasLogDrvHbaIndex type: gauge - labelname: cpqSasLogDrvIndex type: gauge - name: cpqSasTapeDrvHbaIndex oid: 1.3.6.1.4.1.232.5.5.4.1.1.1 type: gauge help: SAS Tape Drive HBA Index - 1.3.6.1.4.1.232.5.5.4.1.1.1 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvIndex oid: 1.3.6.1.4.1.232.5.5.4.1.1.2 type: gauge help: SAS Tape Drive Index - 1.3.6.1.4.1.232.5.5.4.1.1.2 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvLocationString oid: 1.3.6.1.4.1.232.5.5.4.1.1.3 type: DisplayString help: SAS Tape Drive Location String - 1.3.6.1.4.1.232.5.5.4.1.1.3 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvName oid: 1.3.6.1.4.1.232.5.5.4.1.1.4 type: DisplayString help: SAS Tape Drive Name - 1.3.6.1.4.1.232.5.5.4.1.1.4 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvStatus oid: 1.3.6.1.4.1.232.5.5.4.1.1.5 type: gauge help: SAS Physical Drive Status - 1.3.6.1.4.1.232.5.5.4.1.1.5 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge enum_values: 1: other 2: ok 3: offline - name: cpqSasTapeDrvCondition oid: 1.3.6.1.4.1.232.5.5.4.1.1.6 type: gauge help: SAS Tape Drive Condition - 1.3.6.1.4.1.232.5.5.4.1.1.6 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqSasTapeDrvFWRev oid: 1.3.6.1.4.1.232.5.5.4.1.1.7 type: DisplayString help: SAS Tape Drive Firmware Revision - 1.3.6.1.4.1.232.5.5.4.1.1.7 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvSerialNumber oid: 1.3.6.1.4.1.232.5.5.4.1.1.8 type: DisplayString help: SAS Tape Drive Serial Number - 1.3.6.1.4.1.232.5.5.4.1.1.8 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqSasTapeDrvSasAddress oid: 1.3.6.1.4.1.232.5.5.4.1.1.9 type: DisplayString help: SAS Tape Drive SAS Address - 1.3.6.1.4.1.232.5.5.4.1.1.9 indexes: - labelname: cpqSasTapeDrvHbaIndex type: gauge - labelname: cpqSasTapeDrvIndex type: gauge - name: cpqHeResMem2ModuleSize oid: 1.3.6.1.4.1.232.6.2.14.13.1.6 type: gauge help: Module memory size in kilobytes - 1.3.6.1.4.1.232.6.2.14.13.1.6 indexes: - labelname: cpqHeResMem2Module type: gauge - name: cpqHePowerMeterSupport oid: 1.3.6.1.4.1.232.6.2.15.1 type: gauge help: This value specifies whether Power Meter is supported by this Server - 1.3.6.1.4.1.232.6.2.15.1 enum_values: 1: other 2: supported 3: unsupported - name: cpqHePowerMeterStatus oid: 1.3.6.1.4.1.232.6.2.15.2 type: gauge help: This value specifies whether Power Meter reading is supported by this Server - 1.3.6.1.4.1.232.6.2.15.2 enum_values: 1: other 2: present 3: absent - name: cpqHePowerMeterCurrReading oid: 1.3.6.1.4.1.232.6.2.15.3 type: gauge help: This is the current Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.3 - name: cpqHePowerMeterPrevReading oid: 1.3.6.1.4.1.232.6.2.15.4 type: gauge help: This is the previous Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.4 - name: cpqHeHWBiosCondition oid: 1.3.6.1.4.1.232.6.2.16.1 type: gauge help: This value indicates an error has been detected during Pre-OS Test (POST) or during initial hardware initialization - 1.3.6.1.4.1.232.6.2.16.1 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeSysBackupBatteryCondition oid: 1.3.6.1.4.1.232.6.2.17.1 type: gauge help: This value specifies the overall condition of the battery backup sub-system. - 1.3.6.1.4.1.232.6.2.17.1 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeSysBatteryChassis oid: 1.3.6.1.4.1.232.6.2.17.2.1.1 type: gauge help: The system chassis number. - 1.3.6.1.4.1.232.6.2.17.2.1.1 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryIndex oid: 1.3.6.1.4.1.232.6.2.17.2.1.2 type: gauge help: The battery index number within this chassis. - 1.3.6.1.4.1.232.6.2.17.2.1.2 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryPresent oid: 1.3.6.1.4.1.232.6.2.17.2.1.3 type: gauge help: Indicates whether the backup battery is present in the chassis. - 1.3.6.1.4.1.232.6.2.17.2.1.3 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge enum_values: 1: other 2: absent 3: present - name: cpqHeSysBatteryCondition oid: 1.3.6.1.4.1.232.6.2.17.2.1.4 type: gauge help: The condition of the backup battery - 1.3.6.1.4.1.232.6.2.17.2.1.4 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeSysBatteryStatus oid: 1.3.6.1.4.1.232.6.2.17.2.1.5 type: gauge help: The status of the battery. - 1.3.6.1.4.1.232.6.2.17.2.1.5 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge enum_values: 1: noError 2: generalFailure 3: shutdownHighResistance 4: shutdownLowVoltage 5: shutdownShortCircuit 6: shutdownChargeTimeout 7: shutdownOverTemperature 8: shutdownDischargeMinVoltage 9: shutdownDischargeCurrent 10: shutdownLoadCountHigh 11: shutdownEnablePin 12: shutdownOverCurrent 13: shutdownPermanentFailure 14: shutdownBackupTimeExceeded 15: predictiveFailure - name: cpqHeSysBatteryCapacityMaximum oid: 1.3.6.1.4.1.232.6.2.17.2.1.6 type: gauge help: The maximum capacity of the battery in watts. - 1.3.6.1.4.1.232.6.2.17.2.1.6 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryProductName oid: 1.3.6.1.4.1.232.6.2.17.2.1.7 type: DisplayString help: The battery product name. - 1.3.6.1.4.1.232.6.2.17.2.1.7 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryModel oid: 1.3.6.1.4.1.232.6.2.17.2.1.8 type: DisplayString help: The battery model name. - 1.3.6.1.4.1.232.6.2.17.2.1.8 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatterySerialNumber oid: 1.3.6.1.4.1.232.6.2.17.2.1.9 type: DisplayString help: The battery serial number. - 1.3.6.1.4.1.232.6.2.17.2.1.9 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatteryFirmwareRev oid: 1.3.6.1.4.1.232.6.2.17.2.1.10 type: DisplayString help: The battery firmware revision - 1.3.6.1.4.1.232.6.2.17.2.1.10 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeSysBatterySparePartNum oid: 1.3.6.1.4.1.232.6.2.17.2.1.11 type: DisplayString help: The battery part number or spare part number. - 1.3.6.1.4.1.232.6.2.17.2.1.11 indexes: - labelname: cpqHeSysBatteryChassis type: gauge - labelname: cpqHeSysBatteryIndex type: gauge - name: cpqHeTemperatureChassis oid: 1.3.6.1.4.1.232.6.2.6.8.1.1 type: gauge help: The System Chassis number. - 1.3.6.1.4.1.232.6.2.6.8.1.1 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeTemperatureIndex oid: 1.3.6.1.4.1.232.6.2.6.8.1.2 type: gauge help: A number that uniquely specifies this temperature sensor description. - 1.3.6.1.4.1.232.6.2.6.8.1.2 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeTemperatureLocale oid: 1.3.6.1.4.1.232.6.2.6.8.1.3 type: EnumAsInfo help: This specifies the location of the temperature sensor present in the system. - 1.3.6.1.4.1.232.6.2.6.8.1.3 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge enum_values: 1: other 2: unknown 3: system 4: systemBoard 5: ioBoard 6: cpu 7: memory 8: storage 9: removableMedia 10: powerSupply 11: ambient 12: chassis 13: bridgeCard - name: cpqHeTemperatureCelsius oid: 1.3.6.1.4.1.232.6.2.6.8.1.4 type: gauge help: This is the current temperature sensor reading in degrees celsius - 1.3.6.1.4.1.232.6.2.6.8.1.4 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeTemperatureThreshold oid: 1.3.6.1.4.1.232.6.2.6.8.1.5 type: gauge help: This is the shutdown threshold temperature sensor setting in degrees celsius - 1.3.6.1.4.1.232.6.2.6.8.1.5 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeTemperatureCondition oid: 1.3.6.1.4.1.232.6.2.6.8.1.6 type: gauge help: The Temperature sensor condition - 1.3.6.1.4.1.232.6.2.6.8.1.6 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeTemperatureThresholdType oid: 1.3.6.1.4.1.232.6.2.6.8.1.7 type: gauge help: This specifies the type of this instance of temperature sensor - 1.3.6.1.4.1.232.6.2.6.8.1.7 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge enum_values: 1: other 5: blowout 9: caution 15: critical 16: noreaction - name: cpqHeTemperatureHwLocation oid: 1.3.6.1.4.1.232.6.2.6.8.1.8 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the temperature sensor - 1.3.6.1.4.1.232.6.2.6.8.1.8 indexes: - labelname: cpqHeTemperatureChassis type: gauge - labelname: cpqHeTemperatureIndex type: gauge - name: cpqHeFltTolPwrSupplyCondition oid: 1.3.6.1.4.1.232.6.2.9.1 type: gauge help: This value specifies the overall condition of the fault tolerant power supply sub-system. - 1.3.6.1.4.1.232.6.2.9.1 enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeFltTolPwrSupplyStatus oid: 1.3.6.1.4.1.232.6.2.9.2 type: gauge help: This value specifies the status of the fault tolerant power supply. - 1.3.6.1.4.1.232.6.2.9.2 enum_values: 1: other 2: notSupported 3: notInstalled 4: installed - name: cpqHeFltTolPowerSupplyChassis oid: 1.3.6.1.4.1.232.6.2.9.3.1.1 type: gauge help: The system chassis number. - 1.3.6.1.4.1.232.6.2.9.3.1.1 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyBay oid: 1.3.6.1.4.1.232.6.2.9.3.1.2 type: gauge help: The bay number to index within this chassis. - 1.3.6.1.4.1.232.6.2.9.3.1.2 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyPresent oid: 1.3.6.1.4.1.232.6.2.9.3.1.3 type: gauge help: Indicates whether the power supply is present in the chassis. - 1.3.6.1.4.1.232.6.2.9.3.1.3 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: other 2: absent 3: present - name: cpqHeFltTolPowerSupplyCondition oid: 1.3.6.1.4.1.232.6.2.9.3.1.4 type: gauge help: The condition of the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.4 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: other 2: ok 3: degraded 4: failed - name: cpqHeFltTolPowerSupplyStatus oid: 1.3.6.1.4.1.232.6.2.9.3.1.5 type: gauge help: The status of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.5 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: noError 2: generalFailure 3: bistFailure 4: fanFailure 5: tempFailure 6: interlockOpen 7: epromFailed 8: vrefFailed 9: dacFailed 10: ramTestFailed 11: voltageChannelFailed 12: orringdiodeFailed 13: brownOut 14: giveupOnStartup 15: nvramInvalid 16: calibrationTableInvalid 17: noPowerInput - name: cpqHeFltTolPowerSupplyMainVoltage oid: 1.3.6.1.4.1.232.6.2.9.3.1.6 type: gauge help: The input main voltage of the power supply in volts. - 1.3.6.1.4.1.232.6.2.9.3.1.6 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyCapacityUsed oid: 1.3.6.1.4.1.232.6.2.9.3.1.7 type: gauge help: The currently used capacity of the power supply in watts. - 1.3.6.1.4.1.232.6.2.9.3.1.7 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyCapacityMaximum oid: 1.3.6.1.4.1.232.6.2.9.3.1.8 type: gauge help: The maximum capacity of the power supply in watts. - 1.3.6.1.4.1.232.6.2.9.3.1.8 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyRedundant oid: 1.3.6.1.4.1.232.6.2.9.3.1.9 type: gauge help: The redundancy state of the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.9 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: other 2: notRedundant 3: redundant - name: cpqHeFltTolPowerSupplyModel oid: 1.3.6.1.4.1.232.6.2.9.3.1.10 type: DisplayString help: The power supply model name. - 1.3.6.1.4.1.232.6.2.9.3.1.10 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplySerialNumber oid: 1.3.6.1.4.1.232.6.2.9.3.1.11 type: DisplayString help: The power supply serial number. - 1.3.6.1.4.1.232.6.2.9.3.1.11 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyAutoRev oid: 1.3.6.1.4.1.232.6.2.9.3.1.12 type: OctetString help: The power supply auto revision number. - 1.3.6.1.4.1.232.6.2.9.3.1.12 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyHotPlug oid: 1.3.6.1.4.1.232.6.2.9.3.1.13 type: gauge help: This indicates if the power supply is capable of being removed and/or inserted while the system is in an operational state - 1.3.6.1.4.1.232.6.2.9.3.1.13 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: other 2: nonHotPluggable 3: hotPluggable - name: cpqHeFltTolPowerSupplyFirmwareRev oid: 1.3.6.1.4.1.232.6.2.9.3.1.14 type: DisplayString help: The power supply firmware revision - 1.3.6.1.4.1.232.6.2.9.3.1.14 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyHwLocation oid: 1.3.6.1.4.1.232.6.2.9.3.1.15 type: DisplayString help: A text description of the hardware location, on complex multi SBB hardware only, for the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.15 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplySparePartNum oid: 1.3.6.1.4.1.232.6.2.9.3.1.16 type: DisplayString help: The power supply part number or spare part number. - 1.3.6.1.4.1.232.6.2.9.3.1.16 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyRedundantPartner oid: 1.3.6.1.4.1.232.6.2.9.3.1.17 type: gauge help: This specifies the index of the redundant partner - 1.3.6.1.4.1.232.6.2.9.3.1.17 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge - name: cpqHeFltTolPowerSupplyErrorCondition oid: 1.3.6.1.4.1.232.6.2.9.3.1.18 type: gauge help: The Error condition of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.18 indexes: - labelname: cpqHeFltTolPowerSupplyChassis type: gauge - labelname: cpqHeFltTolPowerSupplyBay type: gauge enum_values: 1: noError 2: generalFailure 3: overvoltage 4: overcurrent 5: overtemperature 6: powerinputloss 7: fanfailure 8: vinhighwarning 9: vinlowwarning 10: vouthighwarning 11: voutlowwarning 12: inlettemphighwarning 13: iinternaltemphighwarning 14: vauxhighwarning 15: vauxlowwarning 16: powersupplymismatch 17: goodinstandby - name: cpqSm2CntlrRomDate oid: 1.3.6.1.4.1.232.9.2.2.1 type: DisplayString help: Remote Insight/ Integrated Lights-Out ROM Date - 1.3.6.1.4.1.232.9.2.2.1 - name: cpqSm2CntlrRomRevision oid: 1.3.6.1.4.1.232.9.2.2.2 type: DisplayString help: Remote Insight/ Integrated Lights-Out ROM Revision - 1.3.6.1.4.1.232.9.2.2.2 - name: cpqSm2CntlrVideoStatus oid: 1.3.6.1.4.1.232.9.2.2.3 type: gauge help: Remote Insight/ Integrated Lights-Out Video Hardware Status - 1.3.6.1.4.1.232.9.2.2.3 enum_values: 1: other 2: enabled 3: disabled - name: cpqSm2CntlrBatteryEnabled oid: 1.3.6.1.4.1.232.9.2.2.4 type: gauge help: Remote Insight Battery Enabled - 1.3.6.1.4.1.232.9.2.2.4 enum_values: 1: other 2: enabled 3: disabled 4: noBattery - name: cpqSm2CntlrBatteryStatus oid: 1.3.6.1.4.1.232.9.2.2.5 type: gauge help: Remote Insight Battery Status - 1.3.6.1.4.1.232.9.2.2.5 enum_values: 1: other 2: batteryOk 3: batteryFailed 4: batteryDisconnected - name: cpqSm2CntlrBatteryPercentCharged oid: 1.3.6.1.4.1.232.9.2.2.6 type: gauge help: Remote Insight Battery Percent Charged - 1.3.6.1.4.1.232.9.2.2.6 - name: cpqSm2CntlrAlertStatus oid: 1.3.6.1.4.1.232.9.2.2.7 type: gauge help: Remote Insight/ Integrated Lights-Out Alerting Status - 1.3.6.1.4.1.232.9.2.2.7 enum_values: 1: other 2: enabled 3: disabled - name: cpqSm2CntlrPendingAlerts oid: 1.3.6.1.4.1.232.9.2.2.8 type: gauge help: Pending Remote Insight/ Integrated Lights-Out alerts - 1.3.6.1.4.1.232.9.2.2.8 enum_values: 1: other 2: noAlertsPending 3: alertsPending 4: clearPendingAlerts - name: cpqSm2CntlrSelfTestErrors oid: 1.3.6.1.4.1.232.9.2.2.9 type: gauge help: Remote Insight/ Integrated Lights-Out Self Test Errors - 1.3.6.1.4.1.232.9.2.2.9 - name: cpqSm2CntlrAgentLocation oid: 1.3.6.1.4.1.232.9.2.2.10 type: gauge help: Remote Insight/ Integrated Lights-Out Agent Location - 1.3.6.1.4.1.232.9.2.2.10 enum_values: 1: hostOsAgent 2: firmwareAgent 3: remoteInsightPciFirmwareAgent 4: enclosureFirmwareAgent - name: cpqSm2CntlrLastDataUpdate oid: 1.3.6.1.4.1.232.9.2.2.11 type: OctetString help: The date and time that the Remote Insight/ Integrated Lights-Out offline data was last updated - 1.3.6.1.4.1.232.9.2.2.11 - name: cpqSm2CntlrDataStatus oid: 1.3.6.1.4.1.232.9.2.2.12 type: gauge help: Remote Insight/ Integrated Lights-Out Host OS Data Status - 1.3.6.1.4.1.232.9.2.2.12 enum_values: 1: other 2: noData 3: onlineData 4: offlineData - name: cpqSm2CntlrColdReboot oid: 1.3.6.1.4.1.232.9.2.2.13 type: gauge help: 'Remote Insight/ Integrated Lights-Out Server Cold Reboot The following values are defined: notAvailable(1) Cold reboot of the system is not available - 1.3.6.1.4.1.232.9.2.2.13' enum_values: 1: notAvailable 2: available 3: doColdReboot - name: cpqSm2CntlrBadLoginAttemptsThresh oid: 1.3.6.1.4.1.232.9.2.2.14 type: gauge help: Maximum Unauthorized Login Attempts Threshold - 1.3.6.1.4.1.232.9.2.2.14 - name: cpqSm2CntlrBoardSerialNumber oid: 1.3.6.1.4.1.232.9.2.2.15 type: DisplayString help: Remote Insight/ Integrated Lights-Out Serial Number - 1.3.6.1.4.1.232.9.2.2.15 - name: cpqSm2CntlrRemoteSessionStatus oid: 1.3.6.1.4.1.232.9.2.2.16 type: gauge help: Remote Insight/ Integrated Lights-Out Session Status - 1.3.6.1.4.1.232.9.2.2.16 enum_values: 1: other 2: active 3: inactive - name: cpqSm2CntlrInterfaceStatus oid: 1.3.6.1.4.1.232.9.2.2.17 type: gauge help: Remote Insight/ Integrated Lights-Out Interface Status - 1.3.6.1.4.1.232.9.2.2.17 enum_values: 1: other 2: ok 3: notResponding - name: cpqSm2CntlrSystemId oid: 1.3.6.1.4.1.232.9.2.2.18 type: DisplayString help: Remote Insight/ Integrated Lights-Out System ID - 1.3.6.1.4.1.232.9.2.2.18 - name: cpqSm2CntlrKeyboardCableStatus oid: 1.3.6.1.4.1.232.9.2.2.19 type: gauge help: Remote Insight Keyboard Cable Status - 1.3.6.1.4.1.232.9.2.2.19 enum_values: 1: other 2: connected 3: disconnected - name: cpqSm2ServerIpAddress oid: 1.3.6.1.4.1.232.9.2.2.20 type: InetAddressIPv4 help: The IP address for this servers connection to the Remote Insight/ Integrated Lights-Out - 1.3.6.1.4.1.232.9.2.2.20 - name: cpqSm2CntlrModel oid: 1.3.6.1.4.1.232.9.2.2.21 type: gauge help: Remote Insight/ Integrated Lights-Out Model - 1.3.6.1.4.1.232.9.2.2.21 enum_values: 1: other 2: eisaRemoteInsightBoard 3: pciRemoteInsightBoard 4: pciLightsOutRemoteInsightBoard 5: pciIntegratedLightsOutRemoteInsight 6: pciLightsOutRemoteInsightBoardII 7: pciIntegratedLightsOutRemoteInsight2 8: pciLightsOut100series 9: pciIntegratedLightsOutRemoteInsight3 10: pciIntegratedLightsOutRemoteInsight4 11: pciIntegratedLightsOutRemoteInsight5 - name: cpqSm2CntlrSelfTestErrorMask oid: 1.3.6.1.4.1.232.9.2.2.22 type: gauge help: Remote Insight/ Integrated Lights-Out Self Test Error Mask - 1.3.6.1.4.1.232.9.2.2.22 - name: cpqSm2CntlrMouseCableStatus oid: 1.3.6.1.4.1.232.9.2.2.23 type: gauge help: Remote Insight Mouse Cable Status - 1.3.6.1.4.1.232.9.2.2.23 enum_values: 1: other 2: connected 3: disconnected - name: cpqSm2CntlrVirtualPowerCableStatus oid: 1.3.6.1.4.1.232.9.2.2.24 type: gauge help: Remote Insight Virtual Power Cable Status - 1.3.6.1.4.1.232.9.2.2.24 enum_values: 1: other 2: connected 3: disconnected 4: notApplicable - name: cpqSm2CntlrExternalPowerCableStatus oid: 1.3.6.1.4.1.232.9.2.2.25 type: gauge help: Remote Insight External Power Cable Status - 1.3.6.1.4.1.232.9.2.2.25 enum_values: 1: other 2: externallyConnected 3: disconnected 4: internallyConnected 5: externallyAndInternallyConnected 6: notApplicable - name: cpqSm2CntlrHostGUID oid: 1.3.6.1.4.1.232.9.2.2.26 type: OctetString help: The globally unique identifier of this server - 1.3.6.1.4.1.232.9.2.2.26 - name: cpqSm2CntlriLOSecurityOverrideSwitchState oid: 1.3.6.1.4.1.232.9.2.2.27 type: gauge help: Integrated Lights-Out Security Override Switch State - 1.3.6.1.4.1.232.9.2.2.27 enum_values: 1: notSupported 2: set 3: notSet - name: cpqSm2CntlrHardwareVer oid: 1.3.6.1.4.1.232.9.2.2.28 type: gauge help: Hardware Version of Remote Insight/ Integrated Lights-Out. - 1.3.6.1.4.1.232.9.2.2.28 - name: cpqSm2CntlrAction oid: 1.3.6.1.4.1.232.9.2.2.29 type: gauge help: Remote Insight/ Integrated Lights-Out Action Flags - 1.3.6.1.4.1.232.9.2.2.29 - name: cpqSm2CntlrLicenseActive oid: 1.3.6.1.4.1.232.9.2.2.30 type: gauge help: Remote Insight License State - 1.3.6.1.4.1.232.9.2.2.30 enum_values: 1: none 2: iloAdvanced 3: iloLight 4: iloAdvancedBlade 5: iloStandard 6: iloEssentials 7: iloScaleOut 8: iloAdvancedPremiumSecurity - name: cpqSm2CntlrLicenseKey oid: 1.3.6.1.4.1.232.9.2.2.31 type: DisplayString help: iLO Active ASCII License key string - 1.3.6.1.4.1.232.9.2.2.31 - name: cpqSm2CntlrServerPowerState oid: 1.3.6.1.4.1.232.9.2.2.32 type: gauge help: The current power state for the server - 1.3.6.1.4.1.232.9.2.2.32 enum_values: 1: unknown 2: poweredOff 3: poweredOn 4: insufficientPowerOrPowerOnDenied - name: cpqSm2CntlrSysAutoShutdownCause oid: 1.3.6.1.4.1.232.9.2.2.33 type: gauge help: Indicate the reason for triggering system auto shutdown or cancelling auto shutdown. - 1.3.6.1.4.1.232.9.2.2.33 enum_values: 1: fanFailure 2: overheatCondition 3: vrmFailure 4: powerSupplyFailure 5: systemRunningOnBatteryBackupUnit 129: aborted 130: fanFailureAborted 131: overheatAborted 132: vrmFailureAborted 133: softPowerDown 134: softwareAutomaticServerRecovery 135: powerSupplyFailureAborted - name: cpqSm2CntlrSecurityState oid: 1.3.6.1.4.1.232.9.2.2.34 type: gauge help: Indicate security state - 1.3.6.1.4.1.232.9.2.2.34 enum_values: 1: factory 2: wipe 3: production 4: highSecurity 5: fips 6: cnsa - name: cpqSm2WDTimerType oid: 1.3.6.1.4.1.232.9.2.2.35 type: gauge help: Indicate the watchdog timer type. - 1.3.6.1.4.1.232.9.2.2.35 enum_values: 1: unknown 2: ipmi - name: cpqSm2WDTimerTimeoutDetails oid: 1.3.6.1.4.1.232.9.2.2.36 type: DisplayString help: Indicate the watchdog timer timeout action and timer details. - 1.3.6.1.4.1.232.9.2.2.36 - name: cpqSm2CntlrOverallSecStatus oid: 1.3.6.1.4.1.232.9.2.2.37 type: gauge help: The field indicates the overall security status. - 1.3.6.1.4.1.232.9.2.2.37 enum_values: 1: Ok 2: Risk 3: Ignored