monitoring: K8sUpgradeChainJobFailed must not double-fire on a compat-gate block
Last night (2026-06-20) the detector + compat-gate fixes worked: the chain
resolved target 1.35.6 and the gate correctly REFUSED it (ESO 0.12 + kyverno
1.16 don't support 1.35), pushing k8s_upgrade_blocked=1 -> K8sUpgradeBlocked
fired as designed. But the refusal also made the preflight Job exit 1
(block() exits 1 on purpose so the Failed Job re-spawns nightly), which tripped
K8sUpgradeChainJobFailed too — a duplicate, misleading "pipeline wedged" alarm
for what is the intended halt-and-alert outcome.

Fix: gate the alert with `unless on() k8s_upgrade_blocked == 1`. A deliberate
block sets that gauge (and it stays 1 until the next preflight resets it), so
the chain-job-failed alert is suppressed for the blocked period; a genuine
wedge / crash / halt-on-alert exits 1 WITHOUT setting it, so it still fires
(preserving the alert's original purpose — catching the pre-in_flight preflight
failure that hid the 5-day 1.34.9 wedge). Runbook + automated-upgrades docs
updated to match.