infra/stacks/monitoring/modules
Viktor Barzin cd13b9d062 monitoring: drop PVAutoExpanding alert — info-only noise, not actionable
PVAutoExpanding fired at >80% used (info severity), but pvc-autoresizer's
threshold is 10% free (= 90% used) — the alert always fired ~10 points
before any action would have been taken, and there was nothing for an
operator to do during that window either. It was a "heads up" that
didn't surface a problem.

Real failure modes are already covered:
  * PVFillingUp (critical, >95% for 10m) — autoresizer didn't keep up
  * PVPredictedFull (warning, predict_linear 24h) — trend toward exhaustion

Sharpened PVFillingUp's annotation to spell out the likely causes
(storage_limit reached, expansion failing, or missing autoresizer
annotations) so the responder doesn't have to recall the runbook.
2026-05-22 14:16:44 +00:00
..
monitoring monitoring: drop PVAutoExpanding alert — info-only noise, not actionable 2026-05-22 14:16:44 +00:00