27129 lines
886 KiB
YAML
27129 lines
886 KiB
YAML
# config:
|
|
# scrape_configs:
|
|
# - job_name: 'idrac-snmp'
|
|
# static_configs:
|
|
# - targets:
|
|
# - idrac.viktorbarzin.lan
|
|
# # metrics_path: /snmp
|
|
# params:
|
|
# module: [dell_idrac]
|
|
# relabel_configs:
|
|
# - source_labels: [__address__]
|
|
# target_label: __param_target
|
|
# - source_labels: [__param_target]
|
|
# target_label: instance
|
|
# - target_label: __address__
|
|
# replacement: idrac.viktorbarzin.lan:161 # The SNMP exporter's Service name and port.
|
|
# service:
|
|
# port: 9102
|
|
podAnnotations:
|
|
prometheus.io/scrape: "true"
|
|
prometheus.io/path: "/snmp?target=idrac.viktorbarzin.lan%3A161&module=dell_idrac"
|
|
prometheus.io/port: "9116"
|
|
|
|
# config: |
|
|
# dell_idrac:
|
|
# walk:
|
|
# - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20
|
|
# - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24
|
|
# - 1.3.6.1.4.1.674.10892.5.2.1
|
|
# - 1.3.6.1.4.1.674.10892.5.2.3
|
|
# - 1.3.6.1.4.1.674.10892.5.2.4
|
|
# - 1.3.6.1.4.1.674.10892.2.4.1.1.13
|
|
# metrics:
|
|
# #OID for your raid components status
|
|
# - name: idrac_virtualDiskComponentStatus
|
|
# oid: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20
|
|
# type: gauge
|
|
# help: The status of the virtual disk itself without the propagation of any contained
|
|
# component status - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20
|
|
# indexes:
|
|
# - labelname: virtualDiskNumber
|
|
# type: gauge
|
|
# #OID for your physical disk status
|
|
# - name: idrac_physicalDiskComponentStatus
|
|
# oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24
|
|
# type: gauge
|
|
# help: The status of the physical disk itself without the propagation of any contained
|
|
# component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24
|
|
# indexes:
|
|
# - labelname: physicalDiskNumber
|
|
# type: gauge
|
|
# #Global System Health
|
|
# - name: idrac_globalSystemStatus
|
|
# oid: 1.3.6.1.4.1.674.10892.5.2.1
|
|
# type: gauge
|
|
# help: This attribute defines the overall rollup status of all components in the
|
|
# system being monitored by the remote access card - 1.3.6.1.4.1.674.10892.5.2.1
|
|
# #Global Storage Health
|
|
# - name: idrac_globalStorageStatus
|
|
# oid: 1.3.6.1.4.1.674.10892.5.2.3
|
|
# type: gauge
|
|
# help: This attribute defines the overall storage status being monitored by the
|
|
# remote access card. - 1.3.6.1.4.1.674.10892.5.2.3
|
|
# #Global Power System Health
|
|
# - name: idrac_systemPowerState
|
|
# oid: 1.3.6.1.4.1.674.10892.5.2.4
|
|
# type: gauge
|
|
# help: This attribute defines the power state of the system. - 1.3.6.1.4.1.674.10892.5.2.4
|
|
# # Power consumption in Watts
|
|
# - name: idrac_drsWattsReading
|
|
# oid: 1.3.6.1.4.1.674.10892.2.4.1.1.13
|
|
# type: gauge
|
|
# help: Defines the instantaneous chassis power usage (in watts).
|
|
# indexes:
|
|
# - labelname: drsWattsReading
|
|
|
|
# WARNING: This file was auto-generated using snmp_exporter generator, manual changes will be lost.
|
|
config: |
|
|
dell_idrac:
|
|
walk:
|
|
- 1.3.6.1.4.1.674.10892.5.2
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14
|
|
- 1.3.6.1.4.1.674.10892.5.4.200
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.12.1
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.30.1.6
|
|
- 1.3.6.1.4.1.674.10892.5.4.700.20.1
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7
|
|
get:
|
|
- 1.3.6.1.2.1.1.3.0
|
|
- 1.3.6.1.4.1.674.10892.5.4.300.50.1.5.1.1
|
|
metrics:
|
|
- name: sysUpTime
|
|
oid: 1.3.6.1.2.1.1.3
|
|
type: gauge
|
|
help: The time (in hundredths of a second) since the network management portion
|
|
of the system was last re-initialized. - 1.3.6.1.2.1.1.3
|
|
- name: globalSystemStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.1
|
|
type: gauge
|
|
help: This attribute defines the overall rollup status of all components in the
|
|
system being monitored by the remote access card - 1.3.6.1.4.1.674.10892.5.2.1
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemLCDStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.2
|
|
type: gauge
|
|
help: This attribute defines the system status as it is reflected by the LCD front
|
|
panel - 1.3.6.1.4.1.674.10892.5.2.2
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: globalStorageStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.3
|
|
type: gauge
|
|
help: This attribute defines the overall storage status being monitored by the
|
|
remote access card. - 1.3.6.1.4.1.674.10892.5.2.3
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemPowerState
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.4
|
|
type: gauge
|
|
help: This attribute defines the power state of the system. - 1.3.6.1.4.1.674.10892.5.2.4
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: "off"
|
|
4: "on"
|
|
- name: systemPowerUpTime
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.5
|
|
type: gauge
|
|
help: This attribute defines the power-up time of the system in seconds. - 1.3.6.1.4.1.674.10892.5.2.5
|
|
- name: processorDevicechassisIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1
|
|
type: gauge
|
|
help: 1100.0030.0001.0001 This attribute defines the index (one based) of the
|
|
associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2
|
|
type: gauge
|
|
help: 1100.0030.0001.0002 This attribute defines the index (one based) of the
|
|
processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceStateCapabilities
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3
|
|
type: gauge
|
|
help: 1100.0030.0001.0003 This attribute defines the state capabilities of the
|
|
processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknownCapabilities
|
|
2: enableCapable
|
|
4: notReadyCapable
|
|
6: enableAndNotReadyCapable
|
|
- name: processorDeviceStateSettings
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4
|
|
type: gauge
|
|
help: 1100.0030.0001.0004 This attribute defines the state settings of the processor
|
|
device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: enabled
|
|
4: notReady
|
|
6: enabledAndNotReady
|
|
- name: processorDeviceStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5
|
|
type: gauge
|
|
help: 1100.0030.0001.0005 This attribute defines the status of the processor device.
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: processorDeviceType
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7
|
|
type: gauge
|
|
help: 1100.0030.0001.0007 This attribute defines the type of the processor device.
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: deviceTypeIsOther
|
|
2: deviceTypeIsUnknown
|
|
3: deviceTypeIsCPU
|
|
4: deviceTypeIsMathProcessor
|
|
5: deviceTypeIsDSP
|
|
6: deviceTypeIsAVideoProcessor
|
|
- name: processorDeviceManufacturerName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8
|
|
type: OctetString
|
|
help: 1100.0030.0001.0008 This attribute defines the name of the manufacturer
|
|
of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceStatusState
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9
|
|
type: gauge
|
|
help: 1100.0030.0001.0009 This attribute defines the status state of the processor
|
|
device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: enabled
|
|
4: userDisabled
|
|
5: biosDisabled
|
|
6: idle
|
|
- name: processorDeviceFamily
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10
|
|
type: gauge
|
|
help: 1100.0030.0001.0010 This attribute defines the family of the processor device.
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: deviceFamilyIsOther
|
|
2: deviceFamilyIsUnknown
|
|
3: deviceFamilyIs8086
|
|
4: deviceFamilyIs80286
|
|
5: deviceFamilyIsIntel386
|
|
6: deviceFamilyIsIntel486
|
|
7: deviceFamilyIs8087
|
|
8: deviceFamilyIs80287
|
|
9: deviceFamilyIs80387
|
|
10: deviceFamilyIs80487
|
|
11: deviceFamilyIsPentium
|
|
12: deviceFamilyIsPentiumPro
|
|
13: deviceFamilyIsPentiumII
|
|
14: deviceFamilyIsPentiumMMX
|
|
15: deviceFamilyIsCeleron
|
|
16: deviceFamilyIsPentiumIIXeon
|
|
17: deviceFamilyIsPentiumIII
|
|
18: deviceFamilyIsPentiumIIIXeon
|
|
19: deviceFamilyIsPentiumIIISpeedStep
|
|
20: deviceFamilyIsItanium
|
|
21: deviceFamilyIsIntelXeon
|
|
22: deviceFamilyIsPentium4
|
|
23: deviceFamilyIsIntelXeonMP
|
|
24: deviceFamilyIsIntelItanium2
|
|
25: deviceFamilyIsK5
|
|
26: deviceFamilyIsK6
|
|
27: deviceFamilyIsK6Dash2
|
|
28: deviceFamilyIsK6Dash3
|
|
29: deviceFamilyIsAMDAthlon
|
|
30: deviceFamilyIsAMD2900
|
|
31: deviceFamilyIsK6Dash2Plus
|
|
32: deviceFamilyIsPowerPC
|
|
33: deviceFamilyIsPowerPC601
|
|
34: deviceFamilyIsPowerPC603
|
|
35: deviceFamilyIsPowerPC603Plus
|
|
36: deviceFamilyIsPowerPC604
|
|
37: deviceFamilyIsPowerPC620
|
|
38: deviceFamilyIsPowerPCx704
|
|
39: deviceFamilyIsPowerPC750
|
|
40: deviceFamilyIsIntelCoreDuo
|
|
41: deviceFamilyIsIntelCoreDuoMobile
|
|
42: deviceFamilyIsIntelCoreSoloMobile
|
|
43: deviceFamilyIsIntelAtom
|
|
48: deviceFamilyIsAlpha
|
|
49: deviceFamilyIsAlpha21064
|
|
50: deviceFamilyIsAlpha21066
|
|
51: deviceFamilyIsAlpha21164
|
|
52: deviceFamilyIsAlpha21164PC
|
|
53: deviceFamilyIsAlpha21164a
|
|
54: deviceFamilyIsAlpha21264
|
|
55: deviceFamilyIsAlpha21364
|
|
56: deviceFamilyIsAMDTurionIIUltraDualMobileM
|
|
57: deviceFamilyIsAMDTurionIIDualMobileM
|
|
58: deviceFamilyIsAMDAthlonIIDualMobileM
|
|
59: deviceFamilyIsAMDOpteron6100
|
|
60: deviceFamilyIsAMDOpteron4100
|
|
61: deviceFamilyIsAMDOpteron6200
|
|
62: deviceFamilyIsAMDOpteron4200
|
|
64: deviceFamilyIsMIPS
|
|
65: deviceFamilyIsMIPSR4000
|
|
66: deviceFamilyIsMIPSR4200
|
|
67: deviceFamilyIsMIPSR4400
|
|
68: deviceFamilyIsMIPSR4600
|
|
69: deviceFamilyIsMIPSR10000
|
|
80: deviceFamilyIsSPARC
|
|
81: deviceFamilyIsSuperSPARC
|
|
82: deviceFamilyIsmicroSPARCII
|
|
83: deviceFamilyIsmicroSPARCIIep
|
|
84: deviceFamilyIsUltraSPARC
|
|
85: deviceFamilyIsUltraSPARCII
|
|
86: deviceFamilyIsUltraSPARCIIi
|
|
87: deviceFamilyIsUltraSPARCIII
|
|
88: deviceFamilyIsUltraSPARCIIIi
|
|
96: deviceFamilyIs68040
|
|
97: deviceFamilyIs68xxx
|
|
98: deviceFamilyIs68000
|
|
99: deviceFamilyIs68010
|
|
100: deviceFamilyIs68020
|
|
101: deviceFamilyIs68030
|
|
107: deviceFamilyIsAMDZen
|
|
112: deviceFamilyIsHobbit
|
|
120: deviceFamilyIsCrusoeTM5000
|
|
121: deviceFamilyIsCrusoeTM3000
|
|
122: deviceFamilyIsEfficeonTM8000
|
|
128: deviceFamilyIsWeitek
|
|
130: deviceFamilyIsIntelCeleronM
|
|
131: deviceFamilyIsAMDAthlon64
|
|
132: deviceFamilyIsAMDOpteron
|
|
133: deviceFamilyIsAMDSempron
|
|
134: deviceFamilyIsAMDTurion64Mobile
|
|
135: deviceFamilyIsDualCoreAMDOpteron
|
|
136: deviceFamilyIsAMDAthlon64X2DualCore
|
|
137: deviceFamilyIsAMDTurion64X2Mobile
|
|
138: deviceFamilyIsQuadCoreAMDOpteron
|
|
139: deviceFamilyIsThirdGenerationAMDOpteron
|
|
140: deviceFamilyIsAMDPhenomFXQuadCore
|
|
141: deviceFamilyIsAMDPhenomX4QuadCore
|
|
142: deviceFamilyIsAMDPhenomX2DualCore
|
|
143: deviceFamilyIsAMDAthlonX2DualCore
|
|
144: deviceFamilyIsPARISC
|
|
145: deviceFamilyIsPARISC8500
|
|
146: deviceFamilyIsPARISC8000
|
|
147: deviceFamilyIsPARISC7300LC
|
|
148: deviceFamilyIsPARISC7200
|
|
149: deviceFamilyIsPARISC7100LC
|
|
150: deviceFamilyIsPARISC7100
|
|
160: deviceFamilyIsV30
|
|
161: deviceFamilyIsQuadCoreIntelXeon3200
|
|
162: deviceFamilyIsDualCoreIntelXeon3000
|
|
163: deviceFamilyIsQuadCoreIntelXeon5300
|
|
164: deviceFamilyIsDualCoreIntelXeon5100
|
|
165: deviceFamilyIsDualCoreIntelXeon5000
|
|
166: deviceFamilyIsDualCoreIntelXeonLV
|
|
167: deviceFamilyIsDualCoreIntelXeonULV
|
|
168: deviceFamilyIsDualCoreIntelXeon7100
|
|
169: deviceFamilyIsQuadCoreIntelXeon5400
|
|
170: deviceFamilyIsQuadCoreIntelXeon
|
|
171: deviceFamilyIsDualCoreIntelXeon5200
|
|
172: deviceFamilyIsDualCoreIntelXeon7200
|
|
173: deviceFamilyIsQuadCoreIntelXeon7300
|
|
174: deviceFamilyIsQuadCoreIntelXeon7400
|
|
175: deviceFamilyIsMultiCoreIntelXeon7400
|
|
176: deviceFamilyIsM1
|
|
177: deviceFamilyIsM2
|
|
179: deviceFamilyIsIntelPentium4HT
|
|
180: deviceFamilyIsAS400
|
|
182: deviceFamilyIsAMDAthlonXP
|
|
183: deviceFamilyIsAMDAthlonMP
|
|
184: deviceFamilyIsAMDDuron
|
|
185: deviceFamilyIsIntelPentiumM
|
|
186: deviceFamilyIsIntelCeleronD
|
|
187: deviceFamilyIsIntelPentiumD
|
|
188: deviceFamilyIsIntelPentiumExtreme
|
|
189: deviceFamilyIsIntelCoreSolo
|
|
190: deviceFamilyIsIntelCore2
|
|
191: deviceFamilyIsIntelCore2Duo
|
|
192: deviceFamilyIsIntelCore2Solo
|
|
193: deviceFamilyIsIntelCore2Extreme
|
|
194: deviceFamilyIsIntelCore2Quad
|
|
195: deviceFamilyIsIntelCore2ExtremeMobile
|
|
196: deviceFamilyIsIntelCore2DuoMobile
|
|
197: deviceFamilyIsIntelCore2SoloMobile
|
|
198: deviceFamilyIsIntelCorei7
|
|
199: deviceFamilyIsDualCoreIntelCeleron
|
|
200: deviceFamilyIsIBM390
|
|
201: deviceFamilyIsG4
|
|
202: deviceFamilyIsG5
|
|
203: deviceFamilyIsESA390G6
|
|
204: deviceFamilyIszArchitectur
|
|
205: deviceFamilyIsIntelCorei5
|
|
206: deviceFamilyIsIntelCorei3
|
|
210: deviceFamilyIsVIAC7M
|
|
211: deviceFamilyIsVIAC7D
|
|
212: deviceFamilyIsVIAC7
|
|
213: deviceFamilyIsVIAEden
|
|
214: deviceFamilyIsMultiCoreIntelXeon
|
|
215: deviceFamilyIsDualCoreIntelXeon3xxx
|
|
216: deviceFamilyIsQuadCoreIntelXeon3xxx
|
|
217: deviceFamilyIsVIANano
|
|
218: deviceFamilyIsDualCoreIntelXeon5xxx
|
|
219: deviceFamilyIsQuadCoreIntelXeon5xxx
|
|
221: deviceFamilyIsDualCoreIntelXeon7xxx
|
|
222: deviceFamilyIsQuadCoreIntelXeon7xxx
|
|
223: deviceFamilyIsMultiCoreIntelXeon7xxx
|
|
224: deviceFamilyIsMultiCoreIntelXeon3400
|
|
230: deviceFamilyIsEmbeddedAMDOpertonQuadCore
|
|
231: deviceFamilyIsAMDPhenomTripleCore
|
|
232: deviceFamilyIsAMDTurionUltraDualCoreMobile
|
|
233: deviceFamilyIsAMDTurionDualCoreMobile
|
|
234: deviceFamilyIsAMDAthlonDualCore
|
|
235: deviceFamilyIsAMDSempronSI
|
|
236: deviceFamilyIsAMDPhenomII
|
|
237: deviceFamilyIsAMDAthlonII
|
|
238: deviceFamilyIsSixCoreAMDOpteron
|
|
239: deviceFamilyIsAMDSempronM
|
|
250: deviceFamilyIsi860
|
|
251: deviceFamilyIsi960
|
|
- name: processorDeviceMaximumSpeed
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11
|
|
type: gauge
|
|
help: 1100.0030.0001.0011 This attribute defines the maximum speed of the processor
|
|
device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceCurrentSpeed
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12
|
|
type: gauge
|
|
help: 1100.0030.0001.0012 This attribute defines the current speed of the processor
|
|
device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceExternalClockSpeed
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13
|
|
type: gauge
|
|
help: 1100.0030.0001.0013 This attribute defines the speed of the external clock
|
|
for the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceVoltage
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14
|
|
type: gauge
|
|
help: 1100.0030.0001.0014 This attribute defines the voltage powering the processor
|
|
device in millivolts - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceVersionName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16
|
|
type: OctetString
|
|
help: 1100.0030.0001.0016 This attribute defines the version of the processor
|
|
device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceCoreCount
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17
|
|
type: gauge
|
|
help: 1100.0030.0001.0017 This attribute defines the number of processor cores
|
|
detected for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceCoreEnabledCount
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18
|
|
type: gauge
|
|
help: 1100.0030.0001.0018 This attribute defines the number of processor cores
|
|
enabled for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceThreadCount
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19
|
|
type: gauge
|
|
help: 1100.0030.0001.0019 This attribute defines the number of processor threads
|
|
detected for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceCharacteristics
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20
|
|
type: gauge
|
|
help: 1100.0030.0001.0020 This attribute defines characteristics of the processor
|
|
device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceExtendedCapabilities
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21
|
|
type: gauge
|
|
help: 1100.0030.0001.0021 This attribute defines extended capabilities of the
|
|
processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceExtendedSettings
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22
|
|
type: gauge
|
|
help: 1100.0030.0001.0022 This attribute defines extended settings of the processor
|
|
device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceBrandName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23
|
|
type: OctetString
|
|
help: 1100.0030.0001.0023 This attribute defines the brand of the processor device.
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceFQDD
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26
|
|
type: OctetString
|
|
help: 1100.0030.0001.0026 Fully qualified device descriptor (FQDD) of the processor
|
|
device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: memoryDeviceSize
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14
|
|
type: gauge
|
|
help: 1100.0050.0001.0014 This attribute defines the size in KBytes of the memory
|
|
device - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14
|
|
indexes:
|
|
- labelname: memoryDevicechassisIndex
|
|
type: gauge
|
|
- labelname: memoryDeviceIndex
|
|
type: gauge
|
|
- name: systemStatechassisIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.1
|
|
type: gauge
|
|
help: 0200.0010.0001.0001 This attribute defines the index (one based) of this
|
|
system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.1
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateGlobalSystemStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.2
|
|
type: gauge
|
|
help: 0200.0010.0001.0002 This attribute defines the global system status of all
|
|
system chassis being monitored by the systems management software. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.2
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateChassisState
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.3
|
|
type: gauge
|
|
help: 0200.0010.0001.0003 This attribute defines the state settings of this system
|
|
chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.3
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: enabled
|
|
4: notReady
|
|
6: enabledAndNotReady
|
|
- name: systemStateChassisStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.4
|
|
type: gauge
|
|
help: 0200.0010.0001.0004 This attribute defines the status of this system chassis.
|
|
- 1.3.6.1.4.1.674.10892.5.4.200.10.1.4
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStatePowerUnitStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.5
|
|
type: OctetString
|
|
help: 0200.0010.0001.0005 This attribute lists the state settings of each power
|
|
unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.5
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStatePowerUnitStatusRedundancy
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.6
|
|
type: gauge
|
|
help: 0200.0010.0001.0006 This attribute defines the combined redundancy status
|
|
of all power units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.6
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: full
|
|
4: degraded
|
|
5: lost
|
|
6: notRedundant
|
|
7: redundancyOffline
|
|
- name: systemStatePowerUnitStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.7
|
|
type: OctetString
|
|
help: 0200.0010.0001.0007 This attribute lists the redundancy status of each power
|
|
unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.7
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStatePowerSupplyStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.8
|
|
type: OctetString
|
|
help: 0200.0010.0001.0008 This attribute lists the state settings of each power
|
|
supply of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.8
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStatePowerSupplyStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.9
|
|
type: gauge
|
|
help: 0200.0010.0001.0009 This attribute defines the combined status of all power
|
|
supplies of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.9
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStatePowerSupplyStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.10
|
|
type: OctetString
|
|
help: 0200.0010.0001.0010 This attribute lists the status of each power supply
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.10
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateVoltageStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.11
|
|
type: OctetString
|
|
help: 0200.0010.0001.0011 This attribute lists the state settings of each voltage
|
|
probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.11
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateVoltageStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.12
|
|
type: gauge
|
|
help: 0200.0010.0001.0012 This attribute defines the combined status of all voltage
|
|
probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.12
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateVoltageStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.13
|
|
type: OctetString
|
|
help: 0200.0010.0001.0013 This attribute lists the status of each voltage probe
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.13
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateAmperageStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.14
|
|
type: OctetString
|
|
help: 0200.0010.0001.0014 This attribute lists the state settings of each amperage
|
|
probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.14
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateAmperageStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.15
|
|
type: gauge
|
|
help: 0200.0010.0001.0015 This attribute defines the combined status of all amperage
|
|
probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.15
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateAmperageStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.16
|
|
type: OctetString
|
|
help: 0200.0010.0001.0016 This attribute lists the status of each amperage probe
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.16
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingUnitStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.17
|
|
type: OctetString
|
|
help: 0200.0010.0001.0017 This attribute lists the state settings of each cooling
|
|
unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.17
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingUnitStatusRedundancy
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.18
|
|
type: gauge
|
|
help: 0200.0010.0001.0018 This attribute defines the combined redundancy status
|
|
of all cooling units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.18
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: full
|
|
4: degraded
|
|
5: lost
|
|
6: notRedundant
|
|
7: redundancyOffline
|
|
- name: systemStateCoolingUnitStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.19
|
|
type: OctetString
|
|
help: 0200.0010.0001.0019 This attribute lists the redundancy status of each cooling
|
|
unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.19
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingDeviceStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.20
|
|
type: OctetString
|
|
help: 0200.0010.0001.0020 This attribute lists the state settings of each cooling
|
|
device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.20
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.21
|
|
type: gauge
|
|
help: 0200.0010.0001.0021 This attribute defines the combined status of all cooling
|
|
devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.21
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateCoolingDeviceStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.22
|
|
type: OctetString
|
|
help: 0200.0010.0001.0022 This attribute lists the status of each cooling device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.22
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateTemperatureStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.23
|
|
type: OctetString
|
|
help: 0200.0010.0001.0023 This attribute lists the state settings of each temperature
|
|
probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.23
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateTemperatureStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.24
|
|
type: gauge
|
|
help: 0200.0010.0001.0024 This attribute defines the combined status of all temperature
|
|
probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.24
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateTemperatureStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.25
|
|
type: OctetString
|
|
help: 0200.0010.0001.0025 This attribute lists the status of each temperature
|
|
probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.25
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateMemoryDeviceStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.26
|
|
type: OctetString
|
|
help: 0200.0010.0001.0026 This attribute lists the state settings of each memory
|
|
device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.26
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateMemoryDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.27
|
|
type: gauge
|
|
help: 0200.0010.0001.0027 This attribute defines the combined status of all memory
|
|
devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.27
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateMemoryDeviceStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.28
|
|
type: OctetString
|
|
help: 0200.0010.0001.0028 This attribute lists the status of each memory device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.28
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateChassisIntrusionStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.29
|
|
type: OctetString
|
|
help: 0200.0010.0001.0029 This attribute lists the state settings of each intrusion
|
|
detection device of this system chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.29
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateChassisIntrusionStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.30
|
|
type: gauge
|
|
help: 0200.0010.0001.0030 This attribute defines the combined status of all intrusion
|
|
detection devices of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.30
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateChassisIntrusionStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.31
|
|
type: OctetString
|
|
help: 0200.0010.0001.0031 This attribute lists the status of each intrusion detection
|
|
device of this system chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.31
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStatePowerUnitStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.42
|
|
type: gauge
|
|
help: 0200.0010.0001.0042 This attribute defines the combined status of all power
|
|
units of this chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.42
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStatePowerUnitStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.43
|
|
type: OctetString
|
|
help: 0200.0010.0001.0043 This attribute lists the status of each power unit of
|
|
this chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.43
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingUnitStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.44
|
|
type: gauge
|
|
help: 0200.0010.0001.0044 This attribute defines the combined status of all cooling
|
|
units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.44
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateCoolingUnitStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.45
|
|
type: OctetString
|
|
help: 0200.0010.0001.0045 This attribute lists the status of each cooling unit
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.45
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateProcessorDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.50
|
|
type: gauge
|
|
help: 0200.0010.0001.0050 This attribute defines the combined status of all processor
|
|
devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.50
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateProcessorDeviceStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.51
|
|
type: OctetString
|
|
help: 0200.0010.0001.0051 This attribute lists the status of each processor device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.51
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateBatteryStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.52
|
|
type: gauge
|
|
help: 0200.0010.0001.0052 This attribute defines the combined status of all batteries
|
|
of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.52
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateBatteryStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.53
|
|
type: OctetString
|
|
help: 0200.0010.0001.0053 This attribute lists the status of each battery of this
|
|
system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.53
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateSDCardUnitStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.54
|
|
type: gauge
|
|
help: 0200.0010.0001.0054 This attribute defines the combined status of all SD
|
|
Card units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.54
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateSDCardUnitStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.55
|
|
type: OctetString
|
|
help: 0200.0010.0001.0055 This attribute lists the status of each SD Card unit
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.55
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateSDCardDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.56
|
|
type: gauge
|
|
help: 0200.0010.0001.0056 This attribute defines the combined status of all SD
|
|
Card devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.56
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateSDCardDeviceStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.57
|
|
type: OctetString
|
|
help: 0200.0010.0001.0057 This attribute lists the status of each SD Card device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.57
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateIDSDMCardUnitStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.58
|
|
type: gauge
|
|
help: 0200.0010.0001.0058 This attribute defines the combined status of all IDSDM
|
|
Card units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.58
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateIDSDMCardUnitStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.59
|
|
type: OctetString
|
|
help: 0200.0010.0001.0059 This attribute lists the status of each IDSDM Card unit
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.59
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateIDSDMCardDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.60
|
|
type: gauge
|
|
help: 0200.0010.0001.0060 This attribute defines the combined status of all IDSDM
|
|
Card devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.60
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateIDSDMCardDeviceStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.61
|
|
type: OctetString
|
|
help: 0200.0010.0001.0061 This attribute lists the status of each IDSDM Card device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.61
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateTemperatureStatisticsStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.62
|
|
type: OctetString
|
|
help: 0200.0010.0001.0062 This attribute lists the state settings of each temperature
|
|
statistics object of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.62
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateTemperatureStatisticsStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.63
|
|
type: gauge
|
|
help: 0200.0010.0001.0063 This attribute defines the combined status of all temperature
|
|
statistics objects of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.63
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateTemperatureStatisticsStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.64
|
|
type: OctetString
|
|
help: 0200.0010.0001.0064 This attribute lists the status of each temperature
|
|
statistics object of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.64
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCMCStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.65
|
|
type: gauge
|
|
help: 0200.0010.0001.0065 This attribute defines the status of CMC. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.65
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemBIOSStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5
|
|
type: gauge
|
|
help: 0300.0050.0001.0005 This attribute defines the status of the system BIOS.
|
|
- 1.3.6.1.4.1.674.10892.5.4.300.50.1.5
|
|
indexes:
|
|
- labelname: systemBIOSchassisIndex
|
|
type: gauge
|
|
- labelname: systemBIOSIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: powerSupplychassisIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.1
|
|
type: gauge
|
|
help: 0600.0012.0001.0001 This attribute defines the index (one based) of the
|
|
system chassis. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.1
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.2
|
|
type: gauge
|
|
help: 0600.0012.0001.0002 This attribute defines the index (one based) of the
|
|
power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.2
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyStateCapabilitiesUnique
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.3
|
|
type: gauge
|
|
help: 0600.0012.0001.0003 This attribute defines the state capabilities of the
|
|
power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.3
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: onlineCapable
|
|
4: notReadyCapable
|
|
- name: powerSupplyStateSettingsUnique
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.4
|
|
type: gauge
|
|
help: 0600.0012.0001.0004 This attribute defines the state settings of the power
|
|
supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.4
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: onLine
|
|
4: notReady
|
|
8: fanFailure
|
|
10: onlineAndFanFailure
|
|
16: powerSupplyIsON
|
|
32: powerSupplyIsOK
|
|
64: acSwitchIsON
|
|
66: onlineandAcSwitchIsON
|
|
128: acPowerIsON
|
|
130: onlineAndAcPowerIsON
|
|
210: onlineAndPredictiveFailure
|
|
242: acPowerAndSwitchAreOnPowerSupplyIsOnIsOkAndOnline
|
|
- name: powerSupplyStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.5
|
|
type: gauge
|
|
help: 0600.0012.0001.0005 This attribute defines the status of the power supply.
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.5
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: powerSupplyOutputWatts
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.6
|
|
type: gauge
|
|
help: 0600.0012.0001.0006 This attribute defines the maximum sustained output
|
|
wattage of the power supply (in tenths of Watts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.6
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyType
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.7
|
|
type: gauge
|
|
help: 0600.0012.0001.0007 This attribute defines the type of the power supply.
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.7
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: powerSupplyTypeIsOther
|
|
2: powerSupplyTypeIsUnknown
|
|
3: powerSupplyTypeIsLinear
|
|
4: powerSupplyTypeIsSwitching
|
|
5: powerSupplyTypeIsBattery
|
|
6: powerSupplyTypeIsUPS
|
|
7: powerSupplyTypeIsConverter
|
|
8: powerSupplyTypeIsRegulator
|
|
9: powerSupplyTypeIsAC
|
|
10: powerSupplyTypeIsDC
|
|
11: powerSupplyTypeIsVRM
|
|
- name: powerSupplyLocationName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.8
|
|
type: OctetString
|
|
help: 0600.0012.0001.0008 This attribute defines the location of the power supply.
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.8
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyMaximumInputVoltage
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.9
|
|
type: gauge
|
|
help: 0600.0012.0001.0009 This attribute defines the maximum input voltage of
|
|
the power supply (in Volts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.9
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplypowerUnitIndexReference
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.10
|
|
type: gauge
|
|
help: 0600.0012.0001.0010 This attribute defines the index to the associated power
|
|
unit if the power supply is part of a power unit. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.10
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplySensorState
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.11
|
|
type: gauge
|
|
help: 0600.0012.0001.0011 This attribute defines the state reported by the power
|
|
supply sensor - 1.3.6.1.4.1.674.10892.5.4.600.12.1.11
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: presenceDetected
|
|
2: psFailureDetected
|
|
4: predictiveFailure
|
|
8: psACLost
|
|
16: acLostOrOutOfRange
|
|
32: acOutOfRangeButPresent
|
|
64: configurationError
|
|
- name: powerSupplyConfigurationErrorType
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.12
|
|
type: gauge
|
|
help: 0600.0012.0001.0012 This attribute defines the type of configuration error
|
|
reported by the power supply sensor - 1.3.6.1.4.1.674.10892.5.4.600.12.1.12
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: vendorMismatch
|
|
2: revisionMismatch
|
|
3: processorMissing
|
|
- name: powerSupplyPowerMonitorCapable
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.13
|
|
type: gauge
|
|
help: 0600.0012.0001.0013 This attribute defines a boolean value that reports
|
|
whether the power supply is capable of monitoring power consumption. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.13
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyRatedInputWattage
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.14
|
|
type: gauge
|
|
help: 0600.0012.0001.0014 This attribute defines the rated input wattage of the
|
|
power supply (in tenths of Watts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.14
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyFQDD
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.15
|
|
type: OctetString
|
|
help: 0600.0012.0001.0015 Fully qualified device descriptor (FQDD) of the power
|
|
supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.15
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyCurrentInputVoltage
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.16
|
|
type: gauge
|
|
help: 0600.0012.0001.0016 This attribute defines the current input voltage to
|
|
the power supply (in Volts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.16
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: amperageProbeReading
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6
|
|
type: gauge
|
|
help: 0600.0030.0001.0006 This attribute defines the reading for an amperage probe
|
|
of type other than amperageProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.600.30.1.6
|
|
indexes:
|
|
- labelname: amperageProbechassisIndex
|
|
type: gauge
|
|
- labelname: amperageProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbechassisIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.1
|
|
type: gauge
|
|
help: 0700.0020.0001.0001 This attribute defines the index (one based) of the
|
|
associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.1
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.2
|
|
type: gauge
|
|
help: 0700.0020.0001.0002 This attribute defines the index (one based) of the
|
|
temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.2
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeStateCapabilities
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.3
|
|
type: gauge
|
|
help: 0700.0020.0001.0003 This attribute defines the state capabilities of the
|
|
temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.3
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknownCapabilities
|
|
2: enableCapable
|
|
4: notReadyCapable
|
|
6: enableAndNotReadyCapable
|
|
- name: temperatureProbeStateSettings
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.4
|
|
type: gauge
|
|
help: 0700.0020.0001.0004 This attribute defines the state settings of the temperature
|
|
probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.4
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: enabled
|
|
4: notReady
|
|
6: enabledAndNotReady
|
|
- name: temperatureProbeStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5
|
|
type: gauge
|
|
help: 0700.0020.0001.0005 This attribute defines the probe status of the temperature
|
|
probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.5
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCriticalUpper
|
|
5: criticalUpper
|
|
6: nonRecoverableUpper
|
|
7: nonCriticalLower
|
|
8: criticalLower
|
|
9: nonRecoverableLower
|
|
10: failed
|
|
- name: temperatureProbeReading
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.6
|
|
type: gauge
|
|
help: 0700.0020.0001.0006 This attribute defines the reading for a temperature
|
|
probe of type other than temperatureProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.20.1.6
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeType
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.7
|
|
type: gauge
|
|
help: 0700.0020.0001.0007 This attribute defines the type of the temperature probe.
|
|
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.7
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: temperatureProbeTypeIsOther
|
|
2: temperatureProbeTypeIsUnknown
|
|
3: temperatureProbeTypeIsAmbientESM
|
|
16: temperatureProbeTypeIsDiscrete
|
|
- name: temperatureProbeLocationName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.8
|
|
type: DisplayString
|
|
help: 0700.0020.0001.0008 This attribute defines the location name of the temperature
|
|
probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.8
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeUpperNonRecoverableThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.9
|
|
type: gauge
|
|
help: 0700.0020.0001.0009 This attribute defines the upper nonrecoverable threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.9
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeUpperCriticalThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.10
|
|
type: gauge
|
|
help: 0700.0020.0001.0010 This attribute defines the upper critical threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.10
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeUpperNonCriticalThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.11
|
|
type: gauge
|
|
help: 0700.0020.0001.0011 This attribute defines the upper noncritical threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.11
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeLowerNonCriticalThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.12
|
|
type: gauge
|
|
help: 0700.0020.0001.0012 This attribute defines the lower noncritical threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.12
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeLowerCriticalThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.13
|
|
type: gauge
|
|
help: 0700.0020.0001.0013 This attribute defines the lower critical threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.13
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeLowerNonRecoverableThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.14
|
|
type: gauge
|
|
help: 0700.0020.0001.0014 This attribute defines the lower nonrecoverable threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.14
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeProbeCapabilities
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.15
|
|
type: gauge
|
|
help: 0700.0020.0001.0015 This attribute defines the probe capabilities of the
|
|
temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.15
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: upperNonCriticalThresholdSetCapable
|
|
2: lowerNonCriticalThresholdSetCapable
|
|
4: upperNonCriticalThresholdDefaultCapable
|
|
8: lowerNonCriticalThresholdDefaultCapable
|
|
- name: temperatureProbeDiscreteReading
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.16
|
|
type: gauge
|
|
help: 0700.0020.0001.0016 This attribute defines the reading for a temperature
|
|
probe of type temperatureProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.20.1.16
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: temperatureIsGood
|
|
2: temperatureIsBad
|
|
- name: physicalDiskCapacityInMB
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11
|
|
type: gauge
|
|
help: The size of the physical disk in megabytes. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
- name: physicalDiskComponentStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24
|
|
type: gauge
|
|
help: The status of the physical disk itself without the propagation of any contained
|
|
component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: physicalDiskDisplayName
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55
|
|
type: DisplayString
|
|
help: The physical disk's friendly FQDD as represented in Storage Management.
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
- name: physicalDiskProductID
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6
|
|
type: DisplayString
|
|
help: The model number of the physical disk. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
- name: physicalDiskSerialNo
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7
|
|
type: DisplayString
|
|
help: The physical disk's unique identification number from the manufacturer.
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
version: 2
|
|
auth:
|
|
community: public
|
|
dell_sim:
|
|
walk:
|
|
- 1.3.6.1.4.1.674.10892.5.2
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14
|
|
- 1.3.6.1.4.1.674.10892.5.4.200
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.12.1
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.30.1.6
|
|
- 1.3.6.1.4.1.674.10892.5.4.700.20.1
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7
|
|
get:
|
|
- 1.3.6.1.2.1.1.3.0
|
|
- 1.3.6.1.4.1.674.10892.5.4.300.50.1.5.1.1
|
|
metrics:
|
|
- name: sysUpTime
|
|
oid: 1.3.6.1.2.1.1.3
|
|
type: gauge
|
|
help: The time (in hundredths of a second) since the network management portion
|
|
of the system was last re-initialized. - 1.3.6.1.2.1.1.3
|
|
- name: globalSystemStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.1
|
|
type: gauge
|
|
help: This attribute defines the overall rollup status of all components in the
|
|
system being monitored by the remote access card - 1.3.6.1.4.1.674.10892.5.2.1
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemLCDStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.2
|
|
type: gauge
|
|
help: This attribute defines the system status as it is reflected by the LCD front
|
|
panel - 1.3.6.1.4.1.674.10892.5.2.2
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: globalStorageStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.3
|
|
type: gauge
|
|
help: This attribute defines the overall storage status being monitored by the
|
|
remote access card. - 1.3.6.1.4.1.674.10892.5.2.3
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemPowerState
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.4
|
|
type: gauge
|
|
help: This attribute defines the power state of the system. - 1.3.6.1.4.1.674.10892.5.2.4
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: "off"
|
|
4: "on"
|
|
- name: systemPowerUpTime
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.5
|
|
type: gauge
|
|
help: This attribute defines the power-up time of the system in seconds. - 1.3.6.1.4.1.674.10892.5.2.5
|
|
- name: processorDevicechassisIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1
|
|
type: gauge
|
|
help: 1100.0030.0001.0001 This attribute defines the index (one based) of the
|
|
associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2
|
|
type: gauge
|
|
help: 1100.0030.0001.0002 This attribute defines the index (one based) of the
|
|
processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceStateCapabilities
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3
|
|
type: gauge
|
|
help: 1100.0030.0001.0003 This attribute defines the state capabilities of the
|
|
processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknownCapabilities
|
|
2: enableCapable
|
|
4: notReadyCapable
|
|
6: enableAndNotReadyCapable
|
|
- name: processorDeviceStateSettings
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4
|
|
type: gauge
|
|
help: 1100.0030.0001.0004 This attribute defines the state settings of the processor
|
|
device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: enabled
|
|
4: notReady
|
|
6: enabledAndNotReady
|
|
- name: processorDeviceStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5
|
|
type: gauge
|
|
help: 1100.0030.0001.0005 This attribute defines the status of the processor device.
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: processorDeviceType
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7
|
|
type: gauge
|
|
help: 1100.0030.0001.0007 This attribute defines the type of the processor device.
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: deviceTypeIsOther
|
|
2: deviceTypeIsUnknown
|
|
3: deviceTypeIsCPU
|
|
4: deviceTypeIsMathProcessor
|
|
5: deviceTypeIsDSP
|
|
6: deviceTypeIsAVideoProcessor
|
|
- name: processorDeviceManufacturerName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8
|
|
type: OctetString
|
|
help: 1100.0030.0001.0008 This attribute defines the name of the manufacturer
|
|
of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceStatusState
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9
|
|
type: gauge
|
|
help: 1100.0030.0001.0009 This attribute defines the status state of the processor
|
|
device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: enabled
|
|
4: userDisabled
|
|
5: biosDisabled
|
|
6: idle
|
|
- name: processorDeviceFamily
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10
|
|
type: gauge
|
|
help: 1100.0030.0001.0010 This attribute defines the family of the processor device.
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: deviceFamilyIsOther
|
|
2: deviceFamilyIsUnknown
|
|
3: deviceFamilyIs8086
|
|
4: deviceFamilyIs80286
|
|
5: deviceFamilyIsIntel386
|
|
6: deviceFamilyIsIntel486
|
|
7: deviceFamilyIs8087
|
|
8: deviceFamilyIs80287
|
|
9: deviceFamilyIs80387
|
|
10: deviceFamilyIs80487
|
|
11: deviceFamilyIsPentium
|
|
12: deviceFamilyIsPentiumPro
|
|
13: deviceFamilyIsPentiumII
|
|
14: deviceFamilyIsPentiumMMX
|
|
15: deviceFamilyIsCeleron
|
|
16: deviceFamilyIsPentiumIIXeon
|
|
17: deviceFamilyIsPentiumIII
|
|
18: deviceFamilyIsPentiumIIIXeon
|
|
19: deviceFamilyIsPentiumIIISpeedStep
|
|
20: deviceFamilyIsItanium
|
|
21: deviceFamilyIsIntelXeon
|
|
22: deviceFamilyIsPentium4
|
|
23: deviceFamilyIsIntelXeonMP
|
|
24: deviceFamilyIsIntelItanium2
|
|
25: deviceFamilyIsK5
|
|
26: deviceFamilyIsK6
|
|
27: deviceFamilyIsK6Dash2
|
|
28: deviceFamilyIsK6Dash3
|
|
29: deviceFamilyIsAMDAthlon
|
|
30: deviceFamilyIsAMD2900
|
|
31: deviceFamilyIsK6Dash2Plus
|
|
32: deviceFamilyIsPowerPC
|
|
33: deviceFamilyIsPowerPC601
|
|
34: deviceFamilyIsPowerPC603
|
|
35: deviceFamilyIsPowerPC603Plus
|
|
36: deviceFamilyIsPowerPC604
|
|
37: deviceFamilyIsPowerPC620
|
|
38: deviceFamilyIsPowerPCx704
|
|
39: deviceFamilyIsPowerPC750
|
|
40: deviceFamilyIsIntelCoreDuo
|
|
41: deviceFamilyIsIntelCoreDuoMobile
|
|
42: deviceFamilyIsIntelCoreSoloMobile
|
|
43: deviceFamilyIsIntelAtom
|
|
48: deviceFamilyIsAlpha
|
|
49: deviceFamilyIsAlpha21064
|
|
50: deviceFamilyIsAlpha21066
|
|
51: deviceFamilyIsAlpha21164
|
|
52: deviceFamilyIsAlpha21164PC
|
|
53: deviceFamilyIsAlpha21164a
|
|
54: deviceFamilyIsAlpha21264
|
|
55: deviceFamilyIsAlpha21364
|
|
56: deviceFamilyIsAMDTurionIIUltraDualMobileM
|
|
57: deviceFamilyIsAMDTurionIIDualMobileM
|
|
58: deviceFamilyIsAMDAthlonIIDualMobileM
|
|
59: deviceFamilyIsAMDOpteron6100
|
|
60: deviceFamilyIsAMDOpteron4100
|
|
61: deviceFamilyIsAMDOpteron6200
|
|
62: deviceFamilyIsAMDOpteron4200
|
|
64: deviceFamilyIsMIPS
|
|
65: deviceFamilyIsMIPSR4000
|
|
66: deviceFamilyIsMIPSR4200
|
|
67: deviceFamilyIsMIPSR4400
|
|
68: deviceFamilyIsMIPSR4600
|
|
69: deviceFamilyIsMIPSR10000
|
|
80: deviceFamilyIsSPARC
|
|
81: deviceFamilyIsSuperSPARC
|
|
82: deviceFamilyIsmicroSPARCII
|
|
83: deviceFamilyIsmicroSPARCIIep
|
|
84: deviceFamilyIsUltraSPARC
|
|
85: deviceFamilyIsUltraSPARCII
|
|
86: deviceFamilyIsUltraSPARCIIi
|
|
87: deviceFamilyIsUltraSPARCIII
|
|
88: deviceFamilyIsUltraSPARCIIIi
|
|
96: deviceFamilyIs68040
|
|
97: deviceFamilyIs68xxx
|
|
98: deviceFamilyIs68000
|
|
99: deviceFamilyIs68010
|
|
100: deviceFamilyIs68020
|
|
101: deviceFamilyIs68030
|
|
107: deviceFamilyIsAMDZen
|
|
112: deviceFamilyIsHobbit
|
|
120: deviceFamilyIsCrusoeTM5000
|
|
121: deviceFamilyIsCrusoeTM3000
|
|
122: deviceFamilyIsEfficeonTM8000
|
|
128: deviceFamilyIsWeitek
|
|
130: deviceFamilyIsIntelCeleronM
|
|
131: deviceFamilyIsAMDAthlon64
|
|
132: deviceFamilyIsAMDOpteron
|
|
133: deviceFamilyIsAMDSempron
|
|
134: deviceFamilyIsAMDTurion64Mobile
|
|
135: deviceFamilyIsDualCoreAMDOpteron
|
|
136: deviceFamilyIsAMDAthlon64X2DualCore
|
|
137: deviceFamilyIsAMDTurion64X2Mobile
|
|
138: deviceFamilyIsQuadCoreAMDOpteron
|
|
139: deviceFamilyIsThirdGenerationAMDOpteron
|
|
140: deviceFamilyIsAMDPhenomFXQuadCore
|
|
141: deviceFamilyIsAMDPhenomX4QuadCore
|
|
142: deviceFamilyIsAMDPhenomX2DualCore
|
|
143: deviceFamilyIsAMDAthlonX2DualCore
|
|
144: deviceFamilyIsPARISC
|
|
145: deviceFamilyIsPARISC8500
|
|
146: deviceFamilyIsPARISC8000
|
|
147: deviceFamilyIsPARISC7300LC
|
|
148: deviceFamilyIsPARISC7200
|
|
149: deviceFamilyIsPARISC7100LC
|
|
150: deviceFamilyIsPARISC7100
|
|
160: deviceFamilyIsV30
|
|
161: deviceFamilyIsQuadCoreIntelXeon3200
|
|
162: deviceFamilyIsDualCoreIntelXeon3000
|
|
163: deviceFamilyIsQuadCoreIntelXeon5300
|
|
164: deviceFamilyIsDualCoreIntelXeon5100
|
|
165: deviceFamilyIsDualCoreIntelXeon5000
|
|
166: deviceFamilyIsDualCoreIntelXeonLV
|
|
167: deviceFamilyIsDualCoreIntelXeonULV
|
|
168: deviceFamilyIsDualCoreIntelXeon7100
|
|
169: deviceFamilyIsQuadCoreIntelXeon5400
|
|
170: deviceFamilyIsQuadCoreIntelXeon
|
|
171: deviceFamilyIsDualCoreIntelXeon5200
|
|
172: deviceFamilyIsDualCoreIntelXeon7200
|
|
173: deviceFamilyIsQuadCoreIntelXeon7300
|
|
174: deviceFamilyIsQuadCoreIntelXeon7400
|
|
175: deviceFamilyIsMultiCoreIntelXeon7400
|
|
176: deviceFamilyIsM1
|
|
177: deviceFamilyIsM2
|
|
179: deviceFamilyIsIntelPentium4HT
|
|
180: deviceFamilyIsAS400
|
|
182: deviceFamilyIsAMDAthlonXP
|
|
183: deviceFamilyIsAMDAthlonMP
|
|
184: deviceFamilyIsAMDDuron
|
|
185: deviceFamilyIsIntelPentiumM
|
|
186: deviceFamilyIsIntelCeleronD
|
|
187: deviceFamilyIsIntelPentiumD
|
|
188: deviceFamilyIsIntelPentiumExtreme
|
|
189: deviceFamilyIsIntelCoreSolo
|
|
190: deviceFamilyIsIntelCore2
|
|
191: deviceFamilyIsIntelCore2Duo
|
|
192: deviceFamilyIsIntelCore2Solo
|
|
193: deviceFamilyIsIntelCore2Extreme
|
|
194: deviceFamilyIsIntelCore2Quad
|
|
195: deviceFamilyIsIntelCore2ExtremeMobile
|
|
196: deviceFamilyIsIntelCore2DuoMobile
|
|
197: deviceFamilyIsIntelCore2SoloMobile
|
|
198: deviceFamilyIsIntelCorei7
|
|
199: deviceFamilyIsDualCoreIntelCeleron
|
|
200: deviceFamilyIsIBM390
|
|
201: deviceFamilyIsG4
|
|
202: deviceFamilyIsG5
|
|
203: deviceFamilyIsESA390G6
|
|
204: deviceFamilyIszArchitectur
|
|
205: deviceFamilyIsIntelCorei5
|
|
206: deviceFamilyIsIntelCorei3
|
|
210: deviceFamilyIsVIAC7M
|
|
211: deviceFamilyIsVIAC7D
|
|
212: deviceFamilyIsVIAC7
|
|
213: deviceFamilyIsVIAEden
|
|
214: deviceFamilyIsMultiCoreIntelXeon
|
|
215: deviceFamilyIsDualCoreIntelXeon3xxx
|
|
216: deviceFamilyIsQuadCoreIntelXeon3xxx
|
|
217: deviceFamilyIsVIANano
|
|
218: deviceFamilyIsDualCoreIntelXeon5xxx
|
|
219: deviceFamilyIsQuadCoreIntelXeon5xxx
|
|
221: deviceFamilyIsDualCoreIntelXeon7xxx
|
|
222: deviceFamilyIsQuadCoreIntelXeon7xxx
|
|
223: deviceFamilyIsMultiCoreIntelXeon7xxx
|
|
224: deviceFamilyIsMultiCoreIntelXeon3400
|
|
230: deviceFamilyIsEmbeddedAMDOpertonQuadCore
|
|
231: deviceFamilyIsAMDPhenomTripleCore
|
|
232: deviceFamilyIsAMDTurionUltraDualCoreMobile
|
|
233: deviceFamilyIsAMDTurionDualCoreMobile
|
|
234: deviceFamilyIsAMDAthlonDualCore
|
|
235: deviceFamilyIsAMDSempronSI
|
|
236: deviceFamilyIsAMDPhenomII
|
|
237: deviceFamilyIsAMDAthlonII
|
|
238: deviceFamilyIsSixCoreAMDOpteron
|
|
239: deviceFamilyIsAMDSempronM
|
|
250: deviceFamilyIsi860
|
|
251: deviceFamilyIsi960
|
|
- name: processorDeviceMaximumSpeed
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11
|
|
type: gauge
|
|
help: 1100.0030.0001.0011 This attribute defines the maximum speed of the processor
|
|
device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceCurrentSpeed
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12
|
|
type: gauge
|
|
help: 1100.0030.0001.0012 This attribute defines the current speed of the processor
|
|
device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceExternalClockSpeed
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13
|
|
type: gauge
|
|
help: 1100.0030.0001.0013 This attribute defines the speed of the external clock
|
|
for the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceVoltage
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14
|
|
type: gauge
|
|
help: 1100.0030.0001.0014 This attribute defines the voltage powering the processor
|
|
device in millivolts - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceVersionName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16
|
|
type: OctetString
|
|
help: 1100.0030.0001.0016 This attribute defines the version of the processor
|
|
device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceCoreCount
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17
|
|
type: gauge
|
|
help: 1100.0030.0001.0017 This attribute defines the number of processor cores
|
|
detected for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceCoreEnabledCount
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18
|
|
type: gauge
|
|
help: 1100.0030.0001.0018 This attribute defines the number of processor cores
|
|
enabled for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceThreadCount
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19
|
|
type: gauge
|
|
help: 1100.0030.0001.0019 This attribute defines the number of processor threads
|
|
detected for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceCharacteristics
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20
|
|
type: gauge
|
|
help: 1100.0030.0001.0020 This attribute defines characteristics of the processor
|
|
device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceExtendedCapabilities
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21
|
|
type: gauge
|
|
help: 1100.0030.0001.0021 This attribute defines extended capabilities of the
|
|
processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceExtendedSettings
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22
|
|
type: gauge
|
|
help: 1100.0030.0001.0022 This attribute defines extended settings of the processor
|
|
device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceBrandName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23
|
|
type: OctetString
|
|
help: 1100.0030.0001.0023 This attribute defines the brand of the processor device.
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceFQDD
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26
|
|
type: OctetString
|
|
help: 1100.0030.0001.0026 Fully qualified device descriptor (FQDD) of the processor
|
|
device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: memoryDeviceSize
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14
|
|
type: gauge
|
|
help: 1100.0050.0001.0014 This attribute defines the size in KBytes of the memory
|
|
device - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14
|
|
indexes:
|
|
- labelname: memoryDevicechassisIndex
|
|
type: gauge
|
|
- labelname: memoryDeviceIndex
|
|
type: gauge
|
|
- name: systemStatechassisIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.1
|
|
type: gauge
|
|
help: 0200.0010.0001.0001 This attribute defines the index (one based) of this
|
|
system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.1
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateGlobalSystemStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.2
|
|
type: gauge
|
|
help: 0200.0010.0001.0002 This attribute defines the global system status of all
|
|
system chassis being monitored by the systems management software. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.2
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateChassisState
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.3
|
|
type: gauge
|
|
help: 0200.0010.0001.0003 This attribute defines the state settings of this system
|
|
chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.3
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: enabled
|
|
4: notReady
|
|
6: enabledAndNotReady
|
|
- name: systemStateChassisStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.4
|
|
type: gauge
|
|
help: 0200.0010.0001.0004 This attribute defines the status of this system chassis.
|
|
- 1.3.6.1.4.1.674.10892.5.4.200.10.1.4
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStatePowerUnitStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.5
|
|
type: OctetString
|
|
help: 0200.0010.0001.0005 This attribute lists the state settings of each power
|
|
unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.5
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStatePowerUnitStatusRedundancy
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.6
|
|
type: gauge
|
|
help: 0200.0010.0001.0006 This attribute defines the combined redundancy status
|
|
of all power units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.6
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: full
|
|
4: degraded
|
|
5: lost
|
|
6: notRedundant
|
|
7: redundancyOffline
|
|
- name: systemStatePowerUnitStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.7
|
|
type: OctetString
|
|
help: 0200.0010.0001.0007 This attribute lists the redundancy status of each power
|
|
unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.7
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStatePowerSupplyStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.8
|
|
type: OctetString
|
|
help: 0200.0010.0001.0008 This attribute lists the state settings of each power
|
|
supply of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.8
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStatePowerSupplyStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.9
|
|
type: gauge
|
|
help: 0200.0010.0001.0009 This attribute defines the combined status of all power
|
|
supplies of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.9
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStatePowerSupplyStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.10
|
|
type: OctetString
|
|
help: 0200.0010.0001.0010 This attribute lists the status of each power supply
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.10
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateVoltageStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.11
|
|
type: OctetString
|
|
help: 0200.0010.0001.0011 This attribute lists the state settings of each voltage
|
|
probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.11
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateVoltageStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.12
|
|
type: gauge
|
|
help: 0200.0010.0001.0012 This attribute defines the combined status of all voltage
|
|
probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.12
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateVoltageStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.13
|
|
type: OctetString
|
|
help: 0200.0010.0001.0013 This attribute lists the status of each voltage probe
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.13
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateAmperageStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.14
|
|
type: OctetString
|
|
help: 0200.0010.0001.0014 This attribute lists the state settings of each amperage
|
|
probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.14
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateAmperageStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.15
|
|
type: gauge
|
|
help: 0200.0010.0001.0015 This attribute defines the combined status of all amperage
|
|
probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.15
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateAmperageStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.16
|
|
type: OctetString
|
|
help: 0200.0010.0001.0016 This attribute lists the status of each amperage probe
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.16
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingUnitStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.17
|
|
type: OctetString
|
|
help: 0200.0010.0001.0017 This attribute lists the state settings of each cooling
|
|
unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.17
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingUnitStatusRedundancy
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.18
|
|
type: gauge
|
|
help: 0200.0010.0001.0018 This attribute defines the combined redundancy status
|
|
of all cooling units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.18
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: full
|
|
4: degraded
|
|
5: lost
|
|
6: notRedundant
|
|
7: redundancyOffline
|
|
- name: systemStateCoolingUnitStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.19
|
|
type: OctetString
|
|
help: 0200.0010.0001.0019 This attribute lists the redundancy status of each cooling
|
|
unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.19
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingDeviceStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.20
|
|
type: OctetString
|
|
help: 0200.0010.0001.0020 This attribute lists the state settings of each cooling
|
|
device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.20
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.21
|
|
type: gauge
|
|
help: 0200.0010.0001.0021 This attribute defines the combined status of all cooling
|
|
devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.21
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateCoolingDeviceStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.22
|
|
type: OctetString
|
|
help: 0200.0010.0001.0022 This attribute lists the status of each cooling device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.22
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateTemperatureStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.23
|
|
type: OctetString
|
|
help: 0200.0010.0001.0023 This attribute lists the state settings of each temperature
|
|
probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.23
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateTemperatureStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.24
|
|
type: gauge
|
|
help: 0200.0010.0001.0024 This attribute defines the combined status of all temperature
|
|
probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.24
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateTemperatureStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.25
|
|
type: OctetString
|
|
help: 0200.0010.0001.0025 This attribute lists the status of each temperature
|
|
probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.25
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateMemoryDeviceStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.26
|
|
type: OctetString
|
|
help: 0200.0010.0001.0026 This attribute lists the state settings of each memory
|
|
device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.26
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateMemoryDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.27
|
|
type: gauge
|
|
help: 0200.0010.0001.0027 This attribute defines the combined status of all memory
|
|
devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.27
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateMemoryDeviceStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.28
|
|
type: OctetString
|
|
help: 0200.0010.0001.0028 This attribute lists the status of each memory device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.28
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateChassisIntrusionStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.29
|
|
type: OctetString
|
|
help: 0200.0010.0001.0029 This attribute lists the state settings of each intrusion
|
|
detection device of this system chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.29
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateChassisIntrusionStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.30
|
|
type: gauge
|
|
help: 0200.0010.0001.0030 This attribute defines the combined status of all intrusion
|
|
detection devices of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.30
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateChassisIntrusionStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.31
|
|
type: OctetString
|
|
help: 0200.0010.0001.0031 This attribute lists the status of each intrusion detection
|
|
device of this system chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.31
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStatePowerUnitStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.42
|
|
type: gauge
|
|
help: 0200.0010.0001.0042 This attribute defines the combined status of all power
|
|
units of this chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.42
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStatePowerUnitStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.43
|
|
type: OctetString
|
|
help: 0200.0010.0001.0043 This attribute lists the status of each power unit of
|
|
this chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.43
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingUnitStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.44
|
|
type: gauge
|
|
help: 0200.0010.0001.0044 This attribute defines the combined status of all cooling
|
|
units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.44
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateCoolingUnitStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.45
|
|
type: OctetString
|
|
help: 0200.0010.0001.0045 This attribute lists the status of each cooling unit
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.45
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateProcessorDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.50
|
|
type: gauge
|
|
help: 0200.0010.0001.0050 This attribute defines the combined status of all processor
|
|
devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.50
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateProcessorDeviceStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.51
|
|
type: OctetString
|
|
help: 0200.0010.0001.0051 This attribute lists the status of each processor device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.51
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateBatteryStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.52
|
|
type: gauge
|
|
help: 0200.0010.0001.0052 This attribute defines the combined status of all batteries
|
|
of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.52
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateBatteryStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.53
|
|
type: OctetString
|
|
help: 0200.0010.0001.0053 This attribute lists the status of each battery of this
|
|
system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.53
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateSDCardUnitStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.54
|
|
type: gauge
|
|
help: 0200.0010.0001.0054 This attribute defines the combined status of all SD
|
|
Card units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.54
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateSDCardUnitStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.55
|
|
type: OctetString
|
|
help: 0200.0010.0001.0055 This attribute lists the status of each SD Card unit
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.55
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateSDCardDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.56
|
|
type: gauge
|
|
help: 0200.0010.0001.0056 This attribute defines the combined status of all SD
|
|
Card devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.56
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateSDCardDeviceStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.57
|
|
type: OctetString
|
|
help: 0200.0010.0001.0057 This attribute lists the status of each SD Card device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.57
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateIDSDMCardUnitStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.58
|
|
type: gauge
|
|
help: 0200.0010.0001.0058 This attribute defines the combined status of all IDSDM
|
|
Card units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.58
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateIDSDMCardUnitStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.59
|
|
type: OctetString
|
|
help: 0200.0010.0001.0059 This attribute lists the status of each IDSDM Card unit
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.59
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateIDSDMCardDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.60
|
|
type: gauge
|
|
help: 0200.0010.0001.0060 This attribute defines the combined status of all IDSDM
|
|
Card devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.60
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateIDSDMCardDeviceStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.61
|
|
type: OctetString
|
|
help: 0200.0010.0001.0061 This attribute lists the status of each IDSDM Card device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.61
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateTemperatureStatisticsStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.62
|
|
type: OctetString
|
|
help: 0200.0010.0001.0062 This attribute lists the state settings of each temperature
|
|
statistics object of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.62
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateTemperatureStatisticsStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.63
|
|
type: gauge
|
|
help: 0200.0010.0001.0063 This attribute defines the combined status of all temperature
|
|
statistics objects of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.63
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateTemperatureStatisticsStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.64
|
|
type: OctetString
|
|
help: 0200.0010.0001.0064 This attribute lists the status of each temperature
|
|
statistics object of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.64
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCMCStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.65
|
|
type: gauge
|
|
help: 0200.0010.0001.0065 This attribute defines the status of CMC. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.65
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemBIOSStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5
|
|
type: gauge
|
|
help: 0300.0050.0001.0005 This attribute defines the status of the system BIOS.
|
|
- 1.3.6.1.4.1.674.10892.5.4.300.50.1.5
|
|
indexes:
|
|
- labelname: systemBIOSchassisIndex
|
|
type: gauge
|
|
- labelname: systemBIOSIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: powerSupplychassisIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.1
|
|
type: gauge
|
|
help: 0600.0012.0001.0001 This attribute defines the index (one based) of the
|
|
system chassis. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.1
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.2
|
|
type: gauge
|
|
help: 0600.0012.0001.0002 This attribute defines the index (one based) of the
|
|
power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.2
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyStateCapabilitiesUnique
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.3
|
|
type: gauge
|
|
help: 0600.0012.0001.0003 This attribute defines the state capabilities of the
|
|
power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.3
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: onlineCapable
|
|
4: notReadyCapable
|
|
- name: powerSupplyStateSettingsUnique
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.4
|
|
type: gauge
|
|
help: 0600.0012.0001.0004 This attribute defines the state settings of the power
|
|
supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.4
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: onLine
|
|
4: notReady
|
|
8: fanFailure
|
|
10: onlineAndFanFailure
|
|
16: powerSupplyIsON
|
|
32: powerSupplyIsOK
|
|
64: acSwitchIsON
|
|
66: onlineandAcSwitchIsON
|
|
128: acPowerIsON
|
|
130: onlineAndAcPowerIsON
|
|
210: onlineAndPredictiveFailure
|
|
242: acPowerAndSwitchAreOnPowerSupplyIsOnIsOkAndOnline
|
|
- name: powerSupplyStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.5
|
|
type: gauge
|
|
help: 0600.0012.0001.0005 This attribute defines the status of the power supply.
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.5
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: powerSupplyOutputWatts
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.6
|
|
type: gauge
|
|
help: 0600.0012.0001.0006 This attribute defines the maximum sustained output
|
|
wattage of the power supply (in tenths of Watts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.6
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyType
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.7
|
|
type: gauge
|
|
help: 0600.0012.0001.0007 This attribute defines the type of the power supply.
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.7
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: powerSupplyTypeIsOther
|
|
2: powerSupplyTypeIsUnknown
|
|
3: powerSupplyTypeIsLinear
|
|
4: powerSupplyTypeIsSwitching
|
|
5: powerSupplyTypeIsBattery
|
|
6: powerSupplyTypeIsUPS
|
|
7: powerSupplyTypeIsConverter
|
|
8: powerSupplyTypeIsRegulator
|
|
9: powerSupplyTypeIsAC
|
|
10: powerSupplyTypeIsDC
|
|
11: powerSupplyTypeIsVRM
|
|
- name: powerSupplyLocationName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.8
|
|
type: OctetString
|
|
help: 0600.0012.0001.0008 This attribute defines the location of the power supply.
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.8
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyMaximumInputVoltage
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.9
|
|
type: gauge
|
|
help: 0600.0012.0001.0009 This attribute defines the maximum input voltage of
|
|
the power supply (in Volts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.9
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplypowerUnitIndexReference
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.10
|
|
type: gauge
|
|
help: 0600.0012.0001.0010 This attribute defines the index to the associated power
|
|
unit if the power supply is part of a power unit. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.10
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplySensorState
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.11
|
|
type: gauge
|
|
help: 0600.0012.0001.0011 This attribute defines the state reported by the power
|
|
supply sensor - 1.3.6.1.4.1.674.10892.5.4.600.12.1.11
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: presenceDetected
|
|
2: psFailureDetected
|
|
4: predictiveFailure
|
|
8: psACLost
|
|
16: acLostOrOutOfRange
|
|
32: acOutOfRangeButPresent
|
|
64: configurationError
|
|
- name: powerSupplyConfigurationErrorType
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.12
|
|
type: gauge
|
|
help: 0600.0012.0001.0012 This attribute defines the type of configuration error
|
|
reported by the power supply sensor - 1.3.6.1.4.1.674.10892.5.4.600.12.1.12
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: vendorMismatch
|
|
2: revisionMismatch
|
|
3: processorMissing
|
|
- name: powerSupplyPowerMonitorCapable
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.13
|
|
type: gauge
|
|
help: 0600.0012.0001.0013 This attribute defines a boolean value that reports
|
|
whether the power supply is capable of monitoring power consumption. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.13
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyRatedInputWattage
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.14
|
|
type: gauge
|
|
help: 0600.0012.0001.0014 This attribute defines the rated input wattage of the
|
|
power supply (in tenths of Watts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.14
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyFQDD
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.15
|
|
type: OctetString
|
|
help: 0600.0012.0001.0015 Fully qualified device descriptor (FQDD) of the power
|
|
supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.15
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyCurrentInputVoltage
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.16
|
|
type: gauge
|
|
help: 0600.0012.0001.0016 This attribute defines the current input voltage to
|
|
the power supply (in Volts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.16
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: amperageProbeReading
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6
|
|
type: gauge
|
|
help: 0600.0030.0001.0006 This attribute defines the reading for an amperage probe
|
|
of type other than amperageProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.600.30.1.6
|
|
indexes:
|
|
- labelname: amperageProbechassisIndex
|
|
type: gauge
|
|
- labelname: amperageProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbechassisIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.1
|
|
type: gauge
|
|
help: 0700.0020.0001.0001 This attribute defines the index (one based) of the
|
|
associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.1
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.2
|
|
type: gauge
|
|
help: 0700.0020.0001.0002 This attribute defines the index (one based) of the
|
|
temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.2
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeStateCapabilities
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.3
|
|
type: gauge
|
|
help: 0700.0020.0001.0003 This attribute defines the state capabilities of the
|
|
temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.3
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknownCapabilities
|
|
2: enableCapable
|
|
4: notReadyCapable
|
|
6: enableAndNotReadyCapable
|
|
- name: temperatureProbeStateSettings
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.4
|
|
type: gauge
|
|
help: 0700.0020.0001.0004 This attribute defines the state settings of the temperature
|
|
probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.4
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: enabled
|
|
4: notReady
|
|
6: enabledAndNotReady
|
|
- name: temperatureProbeStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5
|
|
type: gauge
|
|
help: 0700.0020.0001.0005 This attribute defines the probe status of the temperature
|
|
probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.5
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCriticalUpper
|
|
5: criticalUpper
|
|
6: nonRecoverableUpper
|
|
7: nonCriticalLower
|
|
8: criticalLower
|
|
9: nonRecoverableLower
|
|
10: failed
|
|
- name: temperatureProbeReading
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.6
|
|
type: gauge
|
|
help: 0700.0020.0001.0006 This attribute defines the reading for a temperature
|
|
probe of type other than temperatureProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.20.1.6
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeType
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.7
|
|
type: gauge
|
|
help: 0700.0020.0001.0007 This attribute defines the type of the temperature probe.
|
|
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.7
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: temperatureProbeTypeIsOther
|
|
2: temperatureProbeTypeIsUnknown
|
|
3: temperatureProbeTypeIsAmbientESM
|
|
16: temperatureProbeTypeIsDiscrete
|
|
- name: temperatureProbeLocationName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.8
|
|
type: DisplayString
|
|
help: 0700.0020.0001.0008 This attribute defines the location name of the temperature
|
|
probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.8
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeUpperNonRecoverableThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.9
|
|
type: gauge
|
|
help: 0700.0020.0001.0009 This attribute defines the upper nonrecoverable threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.9
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeUpperCriticalThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.10
|
|
type: gauge
|
|
help: 0700.0020.0001.0010 This attribute defines the upper critical threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.10
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeUpperNonCriticalThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.11
|
|
type: gauge
|
|
help: 0700.0020.0001.0011 This attribute defines the upper noncritical threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.11
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeLowerNonCriticalThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.12
|
|
type: gauge
|
|
help: 0700.0020.0001.0012 This attribute defines the lower noncritical threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.12
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeLowerCriticalThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.13
|
|
type: gauge
|
|
help: 0700.0020.0001.0013 This attribute defines the lower critical threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.13
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeLowerNonRecoverableThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.14
|
|
type: gauge
|
|
help: 0700.0020.0001.0014 This attribute defines the lower nonrecoverable threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.14
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeProbeCapabilities
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.15
|
|
type: gauge
|
|
help: 0700.0020.0001.0015 This attribute defines the probe capabilities of the
|
|
temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.15
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: upperNonCriticalThresholdSetCapable
|
|
2: lowerNonCriticalThresholdSetCapable
|
|
4: upperNonCriticalThresholdDefaultCapable
|
|
8: lowerNonCriticalThresholdDefaultCapable
|
|
- name: temperatureProbeDiscreteReading
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.16
|
|
type: gauge
|
|
help: 0700.0020.0001.0016 This attribute defines the reading for a temperature
|
|
probe of type temperatureProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.20.1.16
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: temperatureIsGood
|
|
2: temperatureIsBad
|
|
- name: physicalDiskCapacityInMB
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11
|
|
type: gauge
|
|
help: The size of the physical disk in megabytes. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
- name: physicalDiskComponentStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24
|
|
type: gauge
|
|
help: The status of the physical disk itself without the propagation of any contained
|
|
component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: physicalDiskDisplayName
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55
|
|
type: DisplayString
|
|
help: The physical disk's friendly FQDD as represented in Storage Management.
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
- name: physicalDiskProductID
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6
|
|
type: DisplayString
|
|
help: The model number of the physical disk. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
- name: physicalDiskSerialNo
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7
|
|
type: DisplayString
|
|
help: The physical disk's unique identification number from the manufacturer.
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
version: 2
|
|
auth:
|
|
community: dell_r740xd
|
|
dell_walk:
|
|
walk:
|
|
- 1.3.6.1.4.1.674.10892.5.2
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14
|
|
- 1.3.6.1.4.1.674.10892.5.4.200
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.12.1
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.30.1.6
|
|
- 1.3.6.1.4.1.674.10892.5.4.700.20.1
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7
|
|
get:
|
|
- 1.3.6.1.2.1.1.3.0
|
|
- 1.3.6.1.4.1.674.10892.5.4.300.50.1.5.1.1
|
|
metrics:
|
|
- name: sysUpTime
|
|
oid: 1.3.6.1.2.1.1.3
|
|
type: gauge
|
|
help: The time (in hundredths of a second) since the network management portion
|
|
of the system was last re-initialized. - 1.3.6.1.2.1.1.3
|
|
- name: globalSystemStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.1
|
|
type: gauge
|
|
help: This attribute defines the overall rollup status of all components in the
|
|
system being monitored by the remote access card - 1.3.6.1.4.1.674.10892.5.2.1
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemLCDStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.2
|
|
type: gauge
|
|
help: This attribute defines the system status as it is reflected by the LCD front
|
|
panel - 1.3.6.1.4.1.674.10892.5.2.2
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: globalStorageStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.3
|
|
type: gauge
|
|
help: This attribute defines the overall storage status being monitored by the
|
|
remote access card. - 1.3.6.1.4.1.674.10892.5.2.3
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemPowerState
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.4
|
|
type: gauge
|
|
help: This attribute defines the power state of the system. - 1.3.6.1.4.1.674.10892.5.2.4
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: "off"
|
|
4: "on"
|
|
- name: systemPowerUpTime
|
|
oid: 1.3.6.1.4.1.674.10892.5.2.5
|
|
type: gauge
|
|
help: This attribute defines the power-up time of the system in seconds. - 1.3.6.1.4.1.674.10892.5.2.5
|
|
- name: processorDevicechassisIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1
|
|
type: gauge
|
|
help: 1100.0030.0001.0001 This attribute defines the index (one based) of the
|
|
associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2
|
|
type: gauge
|
|
help: 1100.0030.0001.0002 This attribute defines the index (one based) of the
|
|
processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceStateCapabilities
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3
|
|
type: gauge
|
|
help: 1100.0030.0001.0003 This attribute defines the state capabilities of the
|
|
processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.3
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknownCapabilities
|
|
2: enableCapable
|
|
4: notReadyCapable
|
|
6: enableAndNotReadyCapable
|
|
- name: processorDeviceStateSettings
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4
|
|
type: gauge
|
|
help: 1100.0030.0001.0004 This attribute defines the state settings of the processor
|
|
device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.4
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: enabled
|
|
4: notReady
|
|
6: enabledAndNotReady
|
|
- name: processorDeviceStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5
|
|
type: gauge
|
|
help: 1100.0030.0001.0005 This attribute defines the status of the processor device.
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: processorDeviceType
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7
|
|
type: gauge
|
|
help: 1100.0030.0001.0007 This attribute defines the type of the processor device.
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.7
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: deviceTypeIsOther
|
|
2: deviceTypeIsUnknown
|
|
3: deviceTypeIsCPU
|
|
4: deviceTypeIsMathProcessor
|
|
5: deviceTypeIsDSP
|
|
6: deviceTypeIsAVideoProcessor
|
|
- name: processorDeviceManufacturerName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8
|
|
type: OctetString
|
|
help: 1100.0030.0001.0008 This attribute defines the name of the manufacturer
|
|
of the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.8
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceStatusState
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9
|
|
type: gauge
|
|
help: 1100.0030.0001.0009 This attribute defines the status state of the processor
|
|
device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.9
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: enabled
|
|
4: userDisabled
|
|
5: biosDisabled
|
|
6: idle
|
|
- name: processorDeviceFamily
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10
|
|
type: gauge
|
|
help: 1100.0030.0001.0010 This attribute defines the family of the processor device.
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.10
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: deviceFamilyIsOther
|
|
2: deviceFamilyIsUnknown
|
|
3: deviceFamilyIs8086
|
|
4: deviceFamilyIs80286
|
|
5: deviceFamilyIsIntel386
|
|
6: deviceFamilyIsIntel486
|
|
7: deviceFamilyIs8087
|
|
8: deviceFamilyIs80287
|
|
9: deviceFamilyIs80387
|
|
10: deviceFamilyIs80487
|
|
11: deviceFamilyIsPentium
|
|
12: deviceFamilyIsPentiumPro
|
|
13: deviceFamilyIsPentiumII
|
|
14: deviceFamilyIsPentiumMMX
|
|
15: deviceFamilyIsCeleron
|
|
16: deviceFamilyIsPentiumIIXeon
|
|
17: deviceFamilyIsPentiumIII
|
|
18: deviceFamilyIsPentiumIIIXeon
|
|
19: deviceFamilyIsPentiumIIISpeedStep
|
|
20: deviceFamilyIsItanium
|
|
21: deviceFamilyIsIntelXeon
|
|
22: deviceFamilyIsPentium4
|
|
23: deviceFamilyIsIntelXeonMP
|
|
24: deviceFamilyIsIntelItanium2
|
|
25: deviceFamilyIsK5
|
|
26: deviceFamilyIsK6
|
|
27: deviceFamilyIsK6Dash2
|
|
28: deviceFamilyIsK6Dash3
|
|
29: deviceFamilyIsAMDAthlon
|
|
30: deviceFamilyIsAMD2900
|
|
31: deviceFamilyIsK6Dash2Plus
|
|
32: deviceFamilyIsPowerPC
|
|
33: deviceFamilyIsPowerPC601
|
|
34: deviceFamilyIsPowerPC603
|
|
35: deviceFamilyIsPowerPC603Plus
|
|
36: deviceFamilyIsPowerPC604
|
|
37: deviceFamilyIsPowerPC620
|
|
38: deviceFamilyIsPowerPCx704
|
|
39: deviceFamilyIsPowerPC750
|
|
40: deviceFamilyIsIntelCoreDuo
|
|
41: deviceFamilyIsIntelCoreDuoMobile
|
|
42: deviceFamilyIsIntelCoreSoloMobile
|
|
43: deviceFamilyIsIntelAtom
|
|
48: deviceFamilyIsAlpha
|
|
49: deviceFamilyIsAlpha21064
|
|
50: deviceFamilyIsAlpha21066
|
|
51: deviceFamilyIsAlpha21164
|
|
52: deviceFamilyIsAlpha21164PC
|
|
53: deviceFamilyIsAlpha21164a
|
|
54: deviceFamilyIsAlpha21264
|
|
55: deviceFamilyIsAlpha21364
|
|
56: deviceFamilyIsAMDTurionIIUltraDualMobileM
|
|
57: deviceFamilyIsAMDTurionIIDualMobileM
|
|
58: deviceFamilyIsAMDAthlonIIDualMobileM
|
|
59: deviceFamilyIsAMDOpteron6100
|
|
60: deviceFamilyIsAMDOpteron4100
|
|
61: deviceFamilyIsAMDOpteron6200
|
|
62: deviceFamilyIsAMDOpteron4200
|
|
64: deviceFamilyIsMIPS
|
|
65: deviceFamilyIsMIPSR4000
|
|
66: deviceFamilyIsMIPSR4200
|
|
67: deviceFamilyIsMIPSR4400
|
|
68: deviceFamilyIsMIPSR4600
|
|
69: deviceFamilyIsMIPSR10000
|
|
80: deviceFamilyIsSPARC
|
|
81: deviceFamilyIsSuperSPARC
|
|
82: deviceFamilyIsmicroSPARCII
|
|
83: deviceFamilyIsmicroSPARCIIep
|
|
84: deviceFamilyIsUltraSPARC
|
|
85: deviceFamilyIsUltraSPARCII
|
|
86: deviceFamilyIsUltraSPARCIIi
|
|
87: deviceFamilyIsUltraSPARCIII
|
|
88: deviceFamilyIsUltraSPARCIIIi
|
|
96: deviceFamilyIs68040
|
|
97: deviceFamilyIs68xxx
|
|
98: deviceFamilyIs68000
|
|
99: deviceFamilyIs68010
|
|
100: deviceFamilyIs68020
|
|
101: deviceFamilyIs68030
|
|
107: deviceFamilyIsAMDZen
|
|
112: deviceFamilyIsHobbit
|
|
120: deviceFamilyIsCrusoeTM5000
|
|
121: deviceFamilyIsCrusoeTM3000
|
|
122: deviceFamilyIsEfficeonTM8000
|
|
128: deviceFamilyIsWeitek
|
|
130: deviceFamilyIsIntelCeleronM
|
|
131: deviceFamilyIsAMDAthlon64
|
|
132: deviceFamilyIsAMDOpteron
|
|
133: deviceFamilyIsAMDSempron
|
|
134: deviceFamilyIsAMDTurion64Mobile
|
|
135: deviceFamilyIsDualCoreAMDOpteron
|
|
136: deviceFamilyIsAMDAthlon64X2DualCore
|
|
137: deviceFamilyIsAMDTurion64X2Mobile
|
|
138: deviceFamilyIsQuadCoreAMDOpteron
|
|
139: deviceFamilyIsThirdGenerationAMDOpteron
|
|
140: deviceFamilyIsAMDPhenomFXQuadCore
|
|
141: deviceFamilyIsAMDPhenomX4QuadCore
|
|
142: deviceFamilyIsAMDPhenomX2DualCore
|
|
143: deviceFamilyIsAMDAthlonX2DualCore
|
|
144: deviceFamilyIsPARISC
|
|
145: deviceFamilyIsPARISC8500
|
|
146: deviceFamilyIsPARISC8000
|
|
147: deviceFamilyIsPARISC7300LC
|
|
148: deviceFamilyIsPARISC7200
|
|
149: deviceFamilyIsPARISC7100LC
|
|
150: deviceFamilyIsPARISC7100
|
|
160: deviceFamilyIsV30
|
|
161: deviceFamilyIsQuadCoreIntelXeon3200
|
|
162: deviceFamilyIsDualCoreIntelXeon3000
|
|
163: deviceFamilyIsQuadCoreIntelXeon5300
|
|
164: deviceFamilyIsDualCoreIntelXeon5100
|
|
165: deviceFamilyIsDualCoreIntelXeon5000
|
|
166: deviceFamilyIsDualCoreIntelXeonLV
|
|
167: deviceFamilyIsDualCoreIntelXeonULV
|
|
168: deviceFamilyIsDualCoreIntelXeon7100
|
|
169: deviceFamilyIsQuadCoreIntelXeon5400
|
|
170: deviceFamilyIsQuadCoreIntelXeon
|
|
171: deviceFamilyIsDualCoreIntelXeon5200
|
|
172: deviceFamilyIsDualCoreIntelXeon7200
|
|
173: deviceFamilyIsQuadCoreIntelXeon7300
|
|
174: deviceFamilyIsQuadCoreIntelXeon7400
|
|
175: deviceFamilyIsMultiCoreIntelXeon7400
|
|
176: deviceFamilyIsM1
|
|
177: deviceFamilyIsM2
|
|
179: deviceFamilyIsIntelPentium4HT
|
|
180: deviceFamilyIsAS400
|
|
182: deviceFamilyIsAMDAthlonXP
|
|
183: deviceFamilyIsAMDAthlonMP
|
|
184: deviceFamilyIsAMDDuron
|
|
185: deviceFamilyIsIntelPentiumM
|
|
186: deviceFamilyIsIntelCeleronD
|
|
187: deviceFamilyIsIntelPentiumD
|
|
188: deviceFamilyIsIntelPentiumExtreme
|
|
189: deviceFamilyIsIntelCoreSolo
|
|
190: deviceFamilyIsIntelCore2
|
|
191: deviceFamilyIsIntelCore2Duo
|
|
192: deviceFamilyIsIntelCore2Solo
|
|
193: deviceFamilyIsIntelCore2Extreme
|
|
194: deviceFamilyIsIntelCore2Quad
|
|
195: deviceFamilyIsIntelCore2ExtremeMobile
|
|
196: deviceFamilyIsIntelCore2DuoMobile
|
|
197: deviceFamilyIsIntelCore2SoloMobile
|
|
198: deviceFamilyIsIntelCorei7
|
|
199: deviceFamilyIsDualCoreIntelCeleron
|
|
200: deviceFamilyIsIBM390
|
|
201: deviceFamilyIsG4
|
|
202: deviceFamilyIsG5
|
|
203: deviceFamilyIsESA390G6
|
|
204: deviceFamilyIszArchitectur
|
|
205: deviceFamilyIsIntelCorei5
|
|
206: deviceFamilyIsIntelCorei3
|
|
210: deviceFamilyIsVIAC7M
|
|
211: deviceFamilyIsVIAC7D
|
|
212: deviceFamilyIsVIAC7
|
|
213: deviceFamilyIsVIAEden
|
|
214: deviceFamilyIsMultiCoreIntelXeon
|
|
215: deviceFamilyIsDualCoreIntelXeon3xxx
|
|
216: deviceFamilyIsQuadCoreIntelXeon3xxx
|
|
217: deviceFamilyIsVIANano
|
|
218: deviceFamilyIsDualCoreIntelXeon5xxx
|
|
219: deviceFamilyIsQuadCoreIntelXeon5xxx
|
|
221: deviceFamilyIsDualCoreIntelXeon7xxx
|
|
222: deviceFamilyIsQuadCoreIntelXeon7xxx
|
|
223: deviceFamilyIsMultiCoreIntelXeon7xxx
|
|
224: deviceFamilyIsMultiCoreIntelXeon3400
|
|
230: deviceFamilyIsEmbeddedAMDOpertonQuadCore
|
|
231: deviceFamilyIsAMDPhenomTripleCore
|
|
232: deviceFamilyIsAMDTurionUltraDualCoreMobile
|
|
233: deviceFamilyIsAMDTurionDualCoreMobile
|
|
234: deviceFamilyIsAMDAthlonDualCore
|
|
235: deviceFamilyIsAMDSempronSI
|
|
236: deviceFamilyIsAMDPhenomII
|
|
237: deviceFamilyIsAMDAthlonII
|
|
238: deviceFamilyIsSixCoreAMDOpteron
|
|
239: deviceFamilyIsAMDSempronM
|
|
250: deviceFamilyIsi860
|
|
251: deviceFamilyIsi960
|
|
- name: processorDeviceMaximumSpeed
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11
|
|
type: gauge
|
|
help: 1100.0030.0001.0011 This attribute defines the maximum speed of the processor
|
|
device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceCurrentSpeed
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12
|
|
type: gauge
|
|
help: 1100.0030.0001.0012 This attribute defines the current speed of the processor
|
|
device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceExternalClockSpeed
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13
|
|
type: gauge
|
|
help: 1100.0030.0001.0013 This attribute defines the speed of the external clock
|
|
for the processor device in MHz - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.13
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceVoltage
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14
|
|
type: gauge
|
|
help: 1100.0030.0001.0014 This attribute defines the voltage powering the processor
|
|
device in millivolts - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceVersionName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16
|
|
type: OctetString
|
|
help: 1100.0030.0001.0016 This attribute defines the version of the processor
|
|
device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.16
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceCoreCount
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17
|
|
type: gauge
|
|
help: 1100.0030.0001.0017 This attribute defines the number of processor cores
|
|
detected for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.17
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceCoreEnabledCount
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18
|
|
type: gauge
|
|
help: 1100.0030.0001.0018 This attribute defines the number of processor cores
|
|
enabled for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.18
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceThreadCount
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19
|
|
type: gauge
|
|
help: 1100.0030.0001.0019 This attribute defines the number of processor threads
|
|
detected for the processor device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.19
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceCharacteristics
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20
|
|
type: gauge
|
|
help: 1100.0030.0001.0020 This attribute defines characteristics of the processor
|
|
device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.20
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceExtendedCapabilities
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21
|
|
type: gauge
|
|
help: 1100.0030.0001.0021 This attribute defines extended capabilities of the
|
|
processor device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.21
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceExtendedSettings
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22
|
|
type: gauge
|
|
help: 1100.0030.0001.0022 This attribute defines extended settings of the processor
|
|
device - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.22
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceBrandName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23
|
|
type: OctetString
|
|
help: 1100.0030.0001.0023 This attribute defines the brand of the processor device.
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: processorDeviceFQDD
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26
|
|
type: OctetString
|
|
help: 1100.0030.0001.0026 Fully qualified device descriptor (FQDD) of the processor
|
|
device. - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26
|
|
indexes:
|
|
- labelname: processorDevicechassisIndex
|
|
type: gauge
|
|
- labelname: processorDeviceIndex
|
|
type: gauge
|
|
- name: memoryDeviceSize
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14
|
|
type: gauge
|
|
help: 1100.0050.0001.0014 This attribute defines the size in KBytes of the memory
|
|
device - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.14
|
|
indexes:
|
|
- labelname: memoryDevicechassisIndex
|
|
type: gauge
|
|
- labelname: memoryDeviceIndex
|
|
type: gauge
|
|
- name: systemStatechassisIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.1
|
|
type: gauge
|
|
help: 0200.0010.0001.0001 This attribute defines the index (one based) of this
|
|
system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.1
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateGlobalSystemStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.2
|
|
type: gauge
|
|
help: 0200.0010.0001.0002 This attribute defines the global system status of all
|
|
system chassis being monitored by the systems management software. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.2
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateChassisState
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.3
|
|
type: gauge
|
|
help: 0200.0010.0001.0003 This attribute defines the state settings of this system
|
|
chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.3
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: enabled
|
|
4: notReady
|
|
6: enabledAndNotReady
|
|
- name: systemStateChassisStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.4
|
|
type: gauge
|
|
help: 0200.0010.0001.0004 This attribute defines the status of this system chassis.
|
|
- 1.3.6.1.4.1.674.10892.5.4.200.10.1.4
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStatePowerUnitStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.5
|
|
type: OctetString
|
|
help: 0200.0010.0001.0005 This attribute lists the state settings of each power
|
|
unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.5
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStatePowerUnitStatusRedundancy
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.6
|
|
type: gauge
|
|
help: 0200.0010.0001.0006 This attribute defines the combined redundancy status
|
|
of all power units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.6
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: full
|
|
4: degraded
|
|
5: lost
|
|
6: notRedundant
|
|
7: redundancyOffline
|
|
- name: systemStatePowerUnitStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.7
|
|
type: OctetString
|
|
help: 0200.0010.0001.0007 This attribute lists the redundancy status of each power
|
|
unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.7
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStatePowerSupplyStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.8
|
|
type: OctetString
|
|
help: 0200.0010.0001.0008 This attribute lists the state settings of each power
|
|
supply of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.8
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStatePowerSupplyStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.9
|
|
type: gauge
|
|
help: 0200.0010.0001.0009 This attribute defines the combined status of all power
|
|
supplies of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.9
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStatePowerSupplyStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.10
|
|
type: OctetString
|
|
help: 0200.0010.0001.0010 This attribute lists the status of each power supply
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.10
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateVoltageStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.11
|
|
type: OctetString
|
|
help: 0200.0010.0001.0011 This attribute lists the state settings of each voltage
|
|
probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.11
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateVoltageStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.12
|
|
type: gauge
|
|
help: 0200.0010.0001.0012 This attribute defines the combined status of all voltage
|
|
probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.12
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateVoltageStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.13
|
|
type: OctetString
|
|
help: 0200.0010.0001.0013 This attribute lists the status of each voltage probe
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.13
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateAmperageStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.14
|
|
type: OctetString
|
|
help: 0200.0010.0001.0014 This attribute lists the state settings of each amperage
|
|
probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.14
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateAmperageStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.15
|
|
type: gauge
|
|
help: 0200.0010.0001.0015 This attribute defines the combined status of all amperage
|
|
probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.15
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateAmperageStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.16
|
|
type: OctetString
|
|
help: 0200.0010.0001.0016 This attribute lists the status of each amperage probe
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.16
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingUnitStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.17
|
|
type: OctetString
|
|
help: 0200.0010.0001.0017 This attribute lists the state settings of each cooling
|
|
unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.17
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingUnitStatusRedundancy
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.18
|
|
type: gauge
|
|
help: 0200.0010.0001.0018 This attribute defines the combined redundancy status
|
|
of all cooling units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.18
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: full
|
|
4: degraded
|
|
5: lost
|
|
6: notRedundant
|
|
7: redundancyOffline
|
|
- name: systemStateCoolingUnitStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.19
|
|
type: OctetString
|
|
help: 0200.0010.0001.0019 This attribute lists the redundancy status of each cooling
|
|
unit of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.19
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingDeviceStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.20
|
|
type: OctetString
|
|
help: 0200.0010.0001.0020 This attribute lists the state settings of each cooling
|
|
device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.20
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.21
|
|
type: gauge
|
|
help: 0200.0010.0001.0021 This attribute defines the combined status of all cooling
|
|
devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.21
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateCoolingDeviceStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.22
|
|
type: OctetString
|
|
help: 0200.0010.0001.0022 This attribute lists the status of each cooling device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.22
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateTemperatureStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.23
|
|
type: OctetString
|
|
help: 0200.0010.0001.0023 This attribute lists the state settings of each temperature
|
|
probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.23
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateTemperatureStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.24
|
|
type: gauge
|
|
help: 0200.0010.0001.0024 This attribute defines the combined status of all temperature
|
|
probes of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.24
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateTemperatureStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.25
|
|
type: OctetString
|
|
help: 0200.0010.0001.0025 This attribute lists the status of each temperature
|
|
probe of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.25
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateMemoryDeviceStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.26
|
|
type: OctetString
|
|
help: 0200.0010.0001.0026 This attribute lists the state settings of each memory
|
|
device of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.26
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateMemoryDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.27
|
|
type: gauge
|
|
help: 0200.0010.0001.0027 This attribute defines the combined status of all memory
|
|
devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.27
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateMemoryDeviceStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.28
|
|
type: OctetString
|
|
help: 0200.0010.0001.0028 This attribute lists the status of each memory device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.28
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateChassisIntrusionStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.29
|
|
type: OctetString
|
|
help: 0200.0010.0001.0029 This attribute lists the state settings of each intrusion
|
|
detection device of this system chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.29
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateChassisIntrusionStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.30
|
|
type: gauge
|
|
help: 0200.0010.0001.0030 This attribute defines the combined status of all intrusion
|
|
detection devices of this system chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.30
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateChassisIntrusionStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.31
|
|
type: OctetString
|
|
help: 0200.0010.0001.0031 This attribute lists the status of each intrusion detection
|
|
device of this system chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.31
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStatePowerUnitStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.42
|
|
type: gauge
|
|
help: 0200.0010.0001.0042 This attribute defines the combined status of all power
|
|
units of this chassis. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.42
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStatePowerUnitStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.43
|
|
type: OctetString
|
|
help: 0200.0010.0001.0043 This attribute lists the status of each power unit of
|
|
this chassis - 1.3.6.1.4.1.674.10892.5.4.200.10.1.43
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCoolingUnitStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.44
|
|
type: gauge
|
|
help: 0200.0010.0001.0044 This attribute defines the combined status of all cooling
|
|
units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.44
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateCoolingUnitStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.45
|
|
type: OctetString
|
|
help: 0200.0010.0001.0045 This attribute lists the status of each cooling unit
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.45
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateProcessorDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.50
|
|
type: gauge
|
|
help: 0200.0010.0001.0050 This attribute defines the combined status of all processor
|
|
devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.50
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateProcessorDeviceStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.51
|
|
type: OctetString
|
|
help: 0200.0010.0001.0051 This attribute lists the status of each processor device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.51
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateBatteryStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.52
|
|
type: gauge
|
|
help: 0200.0010.0001.0052 This attribute defines the combined status of all batteries
|
|
of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.52
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateBatteryStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.53
|
|
type: OctetString
|
|
help: 0200.0010.0001.0053 This attribute lists the status of each battery of this
|
|
system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.53
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateSDCardUnitStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.54
|
|
type: gauge
|
|
help: 0200.0010.0001.0054 This attribute defines the combined status of all SD
|
|
Card units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.54
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateSDCardUnitStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.55
|
|
type: OctetString
|
|
help: 0200.0010.0001.0055 This attribute lists the status of each SD Card unit
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.55
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateSDCardDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.56
|
|
type: gauge
|
|
help: 0200.0010.0001.0056 This attribute defines the combined status of all SD
|
|
Card devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.56
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateSDCardDeviceStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.57
|
|
type: OctetString
|
|
help: 0200.0010.0001.0057 This attribute lists the status of each SD Card device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.57
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateIDSDMCardUnitStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.58
|
|
type: gauge
|
|
help: 0200.0010.0001.0058 This attribute defines the combined status of all IDSDM
|
|
Card units of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.58
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateIDSDMCardUnitStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.59
|
|
type: OctetString
|
|
help: 0200.0010.0001.0059 This attribute lists the status of each IDSDM Card unit
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.59
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateIDSDMCardDeviceStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.60
|
|
type: gauge
|
|
help: 0200.0010.0001.0060 This attribute defines the combined status of all IDSDM
|
|
Card devices of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.60
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateIDSDMCardDeviceStatusList
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.61
|
|
type: OctetString
|
|
help: 0200.0010.0001.0061 This attribute lists the status of each IDSDM Card device
|
|
of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.61
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateTemperatureStatisticsStateDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.62
|
|
type: OctetString
|
|
help: 0200.0010.0001.0062 This attribute lists the state settings of each temperature
|
|
statistics object of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.62
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateTemperatureStatisticsStatusCombined
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.63
|
|
type: gauge
|
|
help: 0200.0010.0001.0063 This attribute defines the combined status of all temperature
|
|
statistics objects of this system. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.63
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemStateTemperatureStatisticsStatusDetails
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.64
|
|
type: OctetString
|
|
help: 0200.0010.0001.0064 This attribute lists the status of each temperature
|
|
statistics object of this system - 1.3.6.1.4.1.674.10892.5.4.200.10.1.64
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
- name: systemStateCMCStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.200.10.1.65
|
|
type: gauge
|
|
help: 0200.0010.0001.0065 This attribute defines the status of CMC. - 1.3.6.1.4.1.674.10892.5.4.200.10.1.65
|
|
indexes:
|
|
- labelname: systemStatechassisIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: systemBIOSStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5
|
|
type: gauge
|
|
help: 0300.0050.0001.0005 This attribute defines the status of the system BIOS.
|
|
- 1.3.6.1.4.1.674.10892.5.4.300.50.1.5
|
|
indexes:
|
|
- labelname: systemBIOSchassisIndex
|
|
type: gauge
|
|
- labelname: systemBIOSIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: powerSupplychassisIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.1
|
|
type: gauge
|
|
help: 0600.0012.0001.0001 This attribute defines the index (one based) of the
|
|
system chassis. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.1
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.2
|
|
type: gauge
|
|
help: 0600.0012.0001.0002 This attribute defines the index (one based) of the
|
|
power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.2
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyStateCapabilitiesUnique
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.3
|
|
type: gauge
|
|
help: 0600.0012.0001.0003 This attribute defines the state capabilities of the
|
|
power supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.3
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: onlineCapable
|
|
4: notReadyCapable
|
|
- name: powerSupplyStateSettingsUnique
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.4
|
|
type: gauge
|
|
help: 0600.0012.0001.0004 This attribute defines the state settings of the power
|
|
supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.4
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: onLine
|
|
4: notReady
|
|
8: fanFailure
|
|
10: onlineAndFanFailure
|
|
16: powerSupplyIsON
|
|
32: powerSupplyIsOK
|
|
64: acSwitchIsON
|
|
66: onlineandAcSwitchIsON
|
|
128: acPowerIsON
|
|
130: onlineAndAcPowerIsON
|
|
210: onlineAndPredictiveFailure
|
|
242: acPowerAndSwitchAreOnPowerSupplyIsOnIsOkAndOnline
|
|
- name: powerSupplyStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.5
|
|
type: gauge
|
|
help: 0600.0012.0001.0005 This attribute defines the status of the power supply.
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.5
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: powerSupplyOutputWatts
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.6
|
|
type: gauge
|
|
help: 0600.0012.0001.0006 This attribute defines the maximum sustained output
|
|
wattage of the power supply (in tenths of Watts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.6
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyType
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.7
|
|
type: gauge
|
|
help: 0600.0012.0001.0007 This attribute defines the type of the power supply.
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.7
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: powerSupplyTypeIsOther
|
|
2: powerSupplyTypeIsUnknown
|
|
3: powerSupplyTypeIsLinear
|
|
4: powerSupplyTypeIsSwitching
|
|
5: powerSupplyTypeIsBattery
|
|
6: powerSupplyTypeIsUPS
|
|
7: powerSupplyTypeIsConverter
|
|
8: powerSupplyTypeIsRegulator
|
|
9: powerSupplyTypeIsAC
|
|
10: powerSupplyTypeIsDC
|
|
11: powerSupplyTypeIsVRM
|
|
- name: powerSupplyLocationName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.8
|
|
type: OctetString
|
|
help: 0600.0012.0001.0008 This attribute defines the location of the power supply.
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.8
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyMaximumInputVoltage
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.9
|
|
type: gauge
|
|
help: 0600.0012.0001.0009 This attribute defines the maximum input voltage of
|
|
the power supply (in Volts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.9
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplypowerUnitIndexReference
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.10
|
|
type: gauge
|
|
help: 0600.0012.0001.0010 This attribute defines the index to the associated power
|
|
unit if the power supply is part of a power unit. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.10
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplySensorState
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.11
|
|
type: gauge
|
|
help: 0600.0012.0001.0011 This attribute defines the state reported by the power
|
|
supply sensor - 1.3.6.1.4.1.674.10892.5.4.600.12.1.11
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: presenceDetected
|
|
2: psFailureDetected
|
|
4: predictiveFailure
|
|
8: psACLost
|
|
16: acLostOrOutOfRange
|
|
32: acOutOfRangeButPresent
|
|
64: configurationError
|
|
- name: powerSupplyConfigurationErrorType
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.12
|
|
type: gauge
|
|
help: 0600.0012.0001.0012 This attribute defines the type of configuration error
|
|
reported by the power supply sensor - 1.3.6.1.4.1.674.10892.5.4.600.12.1.12
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: vendorMismatch
|
|
2: revisionMismatch
|
|
3: processorMissing
|
|
- name: powerSupplyPowerMonitorCapable
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.13
|
|
type: gauge
|
|
help: 0600.0012.0001.0013 This attribute defines a boolean value that reports
|
|
whether the power supply is capable of monitoring power consumption. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.13
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyRatedInputWattage
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.14
|
|
type: gauge
|
|
help: 0600.0012.0001.0014 This attribute defines the rated input wattage of the
|
|
power supply (in tenths of Watts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.14
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyFQDD
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.15
|
|
type: OctetString
|
|
help: 0600.0012.0001.0015 Fully qualified device descriptor (FQDD) of the power
|
|
supply. - 1.3.6.1.4.1.674.10892.5.4.600.12.1.15
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: powerSupplyCurrentInputVoltage
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.12.1.16
|
|
type: gauge
|
|
help: 0600.0012.0001.0016 This attribute defines the current input voltage to
|
|
the power supply (in Volts). - 1.3.6.1.4.1.674.10892.5.4.600.12.1.16
|
|
indexes:
|
|
- labelname: powerSupplychassisIndex
|
|
type: gauge
|
|
- labelname: powerSupplyIndex
|
|
type: gauge
|
|
- name: amperageProbeReading
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6
|
|
type: gauge
|
|
help: 0600.0030.0001.0006 This attribute defines the reading for an amperage probe
|
|
of type other than amperageProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.600.30.1.6
|
|
indexes:
|
|
- labelname: amperageProbechassisIndex
|
|
type: gauge
|
|
- labelname: amperageProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbechassisIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.1
|
|
type: gauge
|
|
help: 0700.0020.0001.0001 This attribute defines the index (one based) of the
|
|
associated system chassis. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.1
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeIndex
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.2
|
|
type: gauge
|
|
help: 0700.0020.0001.0002 This attribute defines the index (one based) of the
|
|
temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.2
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeStateCapabilities
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.3
|
|
type: gauge
|
|
help: 0700.0020.0001.0003 This attribute defines the state capabilities of the
|
|
temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.3
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknownCapabilities
|
|
2: enableCapable
|
|
4: notReadyCapable
|
|
6: enableAndNotReadyCapable
|
|
- name: temperatureProbeStateSettings
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.4
|
|
type: gauge
|
|
help: 0700.0020.0001.0004 This attribute defines the state settings of the temperature
|
|
probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.4
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: enabled
|
|
4: notReady
|
|
6: enabledAndNotReady
|
|
- name: temperatureProbeStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5
|
|
type: gauge
|
|
help: 0700.0020.0001.0005 This attribute defines the probe status of the temperature
|
|
probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.5
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCriticalUpper
|
|
5: criticalUpper
|
|
6: nonRecoverableUpper
|
|
7: nonCriticalLower
|
|
8: criticalLower
|
|
9: nonRecoverableLower
|
|
10: failed
|
|
- name: temperatureProbeReading
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.6
|
|
type: gauge
|
|
help: 0700.0020.0001.0006 This attribute defines the reading for a temperature
|
|
probe of type other than temperatureProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.20.1.6
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeType
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.7
|
|
type: gauge
|
|
help: 0700.0020.0001.0007 This attribute defines the type of the temperature probe.
|
|
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.7
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: temperatureProbeTypeIsOther
|
|
2: temperatureProbeTypeIsUnknown
|
|
3: temperatureProbeTypeIsAmbientESM
|
|
16: temperatureProbeTypeIsDiscrete
|
|
- name: temperatureProbeLocationName
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.8
|
|
type: DisplayString
|
|
help: 0700.0020.0001.0008 This attribute defines the location name of the temperature
|
|
probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.8
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeUpperNonRecoverableThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.9
|
|
type: gauge
|
|
help: 0700.0020.0001.0009 This attribute defines the upper nonrecoverable threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.9
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeUpperCriticalThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.10
|
|
type: gauge
|
|
help: 0700.0020.0001.0010 This attribute defines the upper critical threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.10
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeUpperNonCriticalThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.11
|
|
type: gauge
|
|
help: 0700.0020.0001.0011 This attribute defines the upper noncritical threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.11
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeLowerNonCriticalThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.12
|
|
type: gauge
|
|
help: 0700.0020.0001.0012 This attribute defines the lower noncritical threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.12
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeLowerCriticalThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.13
|
|
type: gauge
|
|
help: 0700.0020.0001.0013 This attribute defines the lower critical threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.13
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeLowerNonRecoverableThreshold
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.14
|
|
type: gauge
|
|
help: 0700.0020.0001.0014 This attribute defines the lower nonrecoverable threshold
|
|
of the temperature probe - 1.3.6.1.4.1.674.10892.5.4.700.20.1.14
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
- name: temperatureProbeProbeCapabilities
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.15
|
|
type: gauge
|
|
help: 0700.0020.0001.0015 This attribute defines the probe capabilities of the
|
|
temperature probe. - 1.3.6.1.4.1.674.10892.5.4.700.20.1.15
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: upperNonCriticalThresholdSetCapable
|
|
2: lowerNonCriticalThresholdSetCapable
|
|
4: upperNonCriticalThresholdDefaultCapable
|
|
8: lowerNonCriticalThresholdDefaultCapable
|
|
- name: temperatureProbeDiscreteReading
|
|
oid: 1.3.6.1.4.1.674.10892.5.4.700.20.1.16
|
|
type: gauge
|
|
help: 0700.0020.0001.0016 This attribute defines the reading for a temperature
|
|
probe of type temperatureProbeTypeIsDiscrete - 1.3.6.1.4.1.674.10892.5.4.700.20.1.16
|
|
indexes:
|
|
- labelname: temperatureProbechassisIndex
|
|
type: gauge
|
|
- labelname: temperatureProbeIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: temperatureIsGood
|
|
2: temperatureIsBad
|
|
- name: physicalDiskCapacityInMB
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11
|
|
type: gauge
|
|
help: The size of the physical disk in megabytes. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
- name: physicalDiskComponentStatus
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24
|
|
type: gauge
|
|
help: The status of the physical disk itself without the propagation of any contained
|
|
component status - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: ok
|
|
4: nonCritical
|
|
5: critical
|
|
6: nonRecoverable
|
|
- name: physicalDiskDisplayName
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55
|
|
type: DisplayString
|
|
help: The physical disk's friendly FQDD as represented in Storage Management.
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
- name: physicalDiskProductID
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6
|
|
type: DisplayString
|
|
help: The model number of the physical disk. - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
- name: physicalDiskSerialNo
|
|
oid: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7
|
|
type: DisplayString
|
|
help: The physical disk's unique identification number from the manufacturer.
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7
|
|
indexes:
|
|
- labelname: physicalDiskNumber
|
|
type: gauge
|
|
hpe:
|
|
walk:
|
|
- 1.3.6.1.4.1.232.1.2.2.1.1
|
|
- 1.3.6.1.4.1.232.11
|
|
- 1.3.6.1.4.1.232.14
|
|
- 1.3.6.1.4.1.232.3.2.2.1
|
|
- 1.3.6.1.4.1.232.3.2.3.1.1
|
|
- 1.3.6.1.4.1.232.3.2.5.1.1
|
|
- 1.3.6.1.4.1.232.5
|
|
- 1.3.6.1.4.1.232.6.2.14.13.1.6
|
|
- 1.3.6.1.4.1.232.6.2.15
|
|
- 1.3.6.1.4.1.232.6.2.16
|
|
- 1.3.6.1.4.1.232.6.2.17
|
|
- 1.3.6.1.4.1.232.6.2.6.8.1
|
|
- 1.3.6.1.4.1.232.6.2.9
|
|
- 1.3.6.1.4.1.232.9.2.2
|
|
get:
|
|
- 1.3.6.1.2.1.1.3.0
|
|
metrics:
|
|
- name: sysUpTime
|
|
oid: 1.3.6.1.2.1.1.3
|
|
type: gauge
|
|
help: The time (in hundredths of a second) since the network management portion
|
|
of the system was last re-initialized. - 1.3.6.1.2.1.1.3
|
|
- name: cpqSeCpuUnitIndex
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.1
|
|
type: gauge
|
|
help: This is a number that uniquely specifies a processor unit - 1.3.6.1.4.1.232.1.2.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuSlot
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.2
|
|
type: gauge
|
|
help: This value represents this processor`s slot - 1.3.6.1.4.1.232.1.2.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuName
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.3
|
|
type: DisplayString
|
|
help: The name of this processor - 1.3.6.1.4.1.232.1.2.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuSpeed
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.4
|
|
type: gauge
|
|
help: The current internal speed of this processor in megahertz - 1.3.6.1.4.1.232.1.2.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuStep
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.5
|
|
type: gauge
|
|
help: This step of the processor - 1.3.6.1.4.1.232.1.2.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuStatus
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.6
|
|
type: gauge
|
|
help: The status of the processor - 1.3.6.1.4.1.232.1.2.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
5: disabled
|
|
- name: cpqSeCpuExtSpeed
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.7
|
|
type: gauge
|
|
help: This is the external frequency in megahertz of the processor bus - 1.3.6.1.4.1.232.1.2.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuDesigner
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.8
|
|
type: gauge
|
|
help: This attribute specifies the manufacturer which designs this CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: intel
|
|
3: amd
|
|
4: cyrix
|
|
5: ti
|
|
6: nexgen
|
|
7: compaq
|
|
8: samsung
|
|
9: mitsubishi
|
|
10: mips
|
|
- name: cpqSeCpuSocketNumber
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.9
|
|
type: gauge
|
|
help: The physical socket number of the CPU chip - 1.3.6.1.4.1.232.1.2.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuThreshPassed
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.10
|
|
type: gauge
|
|
help: CPU threshold passed (Exceeded) - 1.3.6.1.4.1.232.1.2.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unsupported
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqSeCpuHwLocation
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.11
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the CPU - 1.3.6.1.4.1.232.1.2.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuCellTablePtr
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.12
|
|
type: gauge
|
|
help: This is the index for the cell in cpqSeCellTable where this CPU is physically
|
|
located. - 1.3.6.1.4.1.232.1.2.2.1.1.12
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuPowerpodStatus
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.13
|
|
type: gauge
|
|
help: This is the status of CPU power pod - 1.3.6.1.4.1.232.1.2.2.1.1.13
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: notfailed
|
|
2: failed
|
|
- name: cpqSeCpuArchitectureRevision
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.14
|
|
type: DisplayString
|
|
help: This is the CPU architecture revision. - 1.3.6.1.4.1.232.1.2.2.1.1.14
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuCore
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.15
|
|
type: gauge
|
|
help: The number of cores in this CPU module - 1.3.6.1.4.1.232.1.2.2.1.1.15
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUSerialNumber
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.16
|
|
type: DisplayString
|
|
help: The OEM serial number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.16
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUPartNumber
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.17
|
|
type: DisplayString
|
|
help: The OEM part number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.17
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUSerialNumberMfgr
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.18
|
|
type: DisplayString
|
|
help: The manufacturer serial number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.18
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUPartNumberMfgr
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.19
|
|
type: DisplayString
|
|
help: The manufacturer part number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.19
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUCoreIndex
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.20
|
|
type: gauge
|
|
help: This is a number that uniquely identifies a core in a CPU unit. - 1.3.6.1.4.1.232.1.2.2.1.1.20
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUMaxSpeed
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.21
|
|
type: gauge
|
|
help: This is the maximum internal speed in megahertz this processor can support
|
|
- 1.3.6.1.4.1.232.1.2.2.1.1.21
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUCoreThreadIndex
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.22
|
|
type: gauge
|
|
help: This is an unique number to identify the running threads in a CPU core.
|
|
- 1.3.6.1.4.1.232.1.2.2.1.1.22
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUChipGenerationName
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.23
|
|
type: DisplayString
|
|
help: CPU chip generation name e.g - 1.3.6.1.4.1.232.1.2.2.1.1.23
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUMultiThreadStatus
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.24
|
|
type: gauge
|
|
help: This OID identifies whether the CPU threading is enabled or not. - 1.3.6.1.4.1.232.1.2.2.1.1.24
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: enabled
|
|
3: disabled
|
|
- name: cpqSeCPUCoreMaxThreads
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.25
|
|
type: gauge
|
|
help: This OID indicates the maximum number of threads that a cpu core is capable
|
|
of. - 1.3.6.1.4.1.232.1.2.2.1.1.25
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuLowPowerStatus
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.26
|
|
type: gauge
|
|
help: Servers like Itanium has capability to lower power supply to CPU if it is
|
|
idle for specified period of time - 1.3.6.1.4.1.232.1.2.2.1.1.26
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: lowpowered
|
|
3: normalpowered
|
|
4: highpowered
|
|
- name: cpqSeCpuPrimary
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.27
|
|
type: gauge
|
|
help: On SMP systems one of the CPU is set to Primary and the other CPUs as secondary
|
|
- 1.3.6.1.4.1.232.1.2.2.1.1.27
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqSeCpuCoreSteppingText
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.28
|
|
type: DisplayString
|
|
help: The processor stepping version string - 1.3.6.1.4.1.232.1.2.2.1.1.28
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuCurrentPerformanceState
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.29
|
|
type: gauge
|
|
help: This OID returns the current performance state of this processor - 1.3.6.1.4.1.232.1.2.2.1.1.29
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuMinPerformanceState
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.30
|
|
type: gauge
|
|
help: This OID returns the minimum performance state set for this processor -
|
|
1.3.6.1.4.1.232.1.2.2.1.1.30
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuMaxPerformanceState
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.31
|
|
type: gauge
|
|
help: This OID returns the maximum performance state set for this processor -
|
|
1.3.6.1.4.1.232.1.2.2.1.1.31
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqHoMibRevMajor
|
|
oid: 1.3.6.1.4.1.232.11.1.1
|
|
type: gauge
|
|
help: The Major Revision level of the MIB - 1.3.6.1.4.1.232.11.1.1
|
|
- name: cpqHoMibRevMinor
|
|
oid: 1.3.6.1.4.1.232.11.1.2
|
|
type: gauge
|
|
help: The Minor Revision level of the MIB - 1.3.6.1.4.1.232.11.1.2
|
|
- name: cpqHoMibCondition
|
|
oid: 1.3.6.1.4.1.232.11.1.3
|
|
type: gauge
|
|
help: The overall condition - 1.3.6.1.4.1.232.11.1.3
|
|
enum_values:
|
|
1: unknown
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoOsCommonPollFreq
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.1
|
|
type: gauge
|
|
help: The Insight Agent`s polling frequency - 1.3.6.1.4.1.232.11.2.1.4.1
|
|
- name: cpqHoOsCommonModuleIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.1
|
|
type: gauge
|
|
help: A unique index for this module description. - 1.3.6.1.4.1.232.11.2.1.4.2.1.1
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoOsCommonModuleName
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.2
|
|
type: DisplayString
|
|
help: The module name. - 1.3.6.1.4.1.232.11.2.1.4.2.1.2
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoOsCommonModuleVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.3
|
|
type: DisplayString
|
|
help: The module version in XX.YY format - 1.3.6.1.4.1.232.11.2.1.4.2.1.3
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoOsCommonModuleDate
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.4
|
|
type: OctetString
|
|
help: The module date - 1.3.6.1.4.1.232.11.2.1.4.2.1.4
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoOsCommonModulePurpose
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.5
|
|
type: DisplayString
|
|
help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.11.2.1.4.2.1.5
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoName
|
|
oid: 1.3.6.1.4.1.232.11.2.2.1
|
|
type: DisplayString
|
|
help: The name of the host operating system (OS). - 1.3.6.1.4.1.232.11.2.2.1
|
|
- name: cpqHoVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.2.2
|
|
type: DisplayString
|
|
help: The version of the host OS. - 1.3.6.1.4.1.232.11.2.2.2
|
|
- name: cpqHoDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.2.3
|
|
type: DisplayString
|
|
help: A further description of the host OS. - 1.3.6.1.4.1.232.11.2.2.3
|
|
- name: cpqHoOsType
|
|
oid: 1.3.6.1.4.1.232.11.2.2.4
|
|
type: gauge
|
|
help: Host Operating system enumeration. - 1.3.6.1.4.1.232.11.2.2.4
|
|
enum_values:
|
|
1: other
|
|
2: netware
|
|
3: windowsnt
|
|
4: sco-unix
|
|
5: unixware
|
|
6: os-2
|
|
7: ms-dos
|
|
8: dos-windows
|
|
9: windows95
|
|
10: windows98
|
|
11: open-vms
|
|
12: nsk
|
|
13: windowsCE
|
|
14: linux
|
|
15: windows2000
|
|
16: tru64UNIX
|
|
17: windows2003
|
|
18: windows2003-x64
|
|
19: solaris
|
|
20: windows2003-ia64
|
|
21: windows2008
|
|
22: windows2008-x64
|
|
23: windows2008-ia64
|
|
24: vmware-esx
|
|
25: vmware-esxi
|
|
26: windows2012
|
|
27: windows7
|
|
28: windows7-x64
|
|
29: windows8
|
|
30: windows8-x64
|
|
31: windows81
|
|
32: windows81-x64
|
|
33: windowsxp
|
|
34: windowsxp-x64
|
|
35: windowsvista
|
|
36: windowsvista-x64
|
|
37: windows2008-r2
|
|
38: windows2012-r2
|
|
39: rhel
|
|
40: rhel-64
|
|
41: solaris-64
|
|
42: sles
|
|
43: sles-64
|
|
44: ubuntu
|
|
45: ubuntu-64
|
|
46: debian
|
|
47: debian-64
|
|
48: linux-64-bit
|
|
49: other-64-bit
|
|
50: centos-32bit
|
|
51: centos-64bit
|
|
52: oracle-linux32
|
|
53: oracle-linux64
|
|
54: apple-osx
|
|
55: windows2016
|
|
56: nanoserver
|
|
57: windows2019
|
|
- name: cpqHoTelnet
|
|
oid: 1.3.6.1.4.1.232.11.2.2.5
|
|
type: gauge
|
|
help: Telnet on socket 23 is available. - 1.3.6.1.4.1.232.11.2.2.5
|
|
enum_values:
|
|
1: other
|
|
2: available
|
|
3: notavailable
|
|
- name: cpqHoSystemRole
|
|
oid: 1.3.6.1.4.1.232.11.2.2.6
|
|
type: DisplayString
|
|
help: The system role - 1.3.6.1.4.1.232.11.2.2.6
|
|
- name: cpqHoSystemRoleDetail
|
|
oid: 1.3.6.1.4.1.232.11.2.2.7
|
|
type: DisplayString
|
|
help: The system detailed description - 1.3.6.1.4.1.232.11.2.2.7
|
|
- name: cpqHoCrashDumpState
|
|
oid: 1.3.6.1.4.1.232.11.2.2.8
|
|
type: gauge
|
|
help: Crash dump state - 1.3.6.1.4.1.232.11.2.2.8
|
|
enum_values:
|
|
1: completememorydump
|
|
2: kernelmemorydump
|
|
3: smallmemorydump
|
|
4: none
|
|
- name: cpqHoCrashDumpCondition
|
|
oid: 1.3.6.1.4.1.232.11.2.2.9
|
|
type: gauge
|
|
help: The condition of the Crash dump configuration. - 1.3.6.1.4.1.232.11.2.2.9
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoCrashDumpMonitoring
|
|
oid: 1.3.6.1.4.1.232.11.2.2.10
|
|
type: gauge
|
|
help: Enable/disable crash dump monitoring - 1.3.6.1.4.1.232.11.2.2.10
|
|
enum_values:
|
|
1: enabled
|
|
2: disabled
|
|
- name: cpqHoMaxLogicalCPUSupported
|
|
oid: 1.3.6.1.4.1.232.11.2.2.11
|
|
type: gauge
|
|
help: Maximum number of logical CPUs supported by Operating System. - 1.3.6.1.4.1.232.11.2.2.11
|
|
- name: cpqHoSystemName
|
|
oid: 1.3.6.1.4.1.232.11.2.2.12
|
|
type: DisplayString
|
|
help: Full computer name of the host - 1.3.6.1.4.1.232.11.2.2.12
|
|
- name: cpqHosysDescr
|
|
oid: 1.3.6.1.4.1.232.11.2.2.13
|
|
type: DisplayString
|
|
help: The value that would be returned in the RFC-1213 sysDescr MIB element -
|
|
1.3.6.1.4.1.232.11.2.2.13
|
|
- name: cpqHoCpuUtilUnitIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.1
|
|
type: gauge
|
|
help: This number uniquely specifies a processor unit - 1.3.6.1.4.1.232.11.2.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilMin
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.2
|
|
type: gauge
|
|
help: The CPU utilization as a percentage of the theoretical maximum during the
|
|
last minute - 1.3.6.1.4.1.232.11.2.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilFiveMin
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.3
|
|
type: gauge
|
|
help: The CPU utilization as a percentage of the theoretical maximum during the
|
|
last five minutes - 1.3.6.1.4.1.232.11.2.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilThirtyMin
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.4
|
|
type: gauge
|
|
help: The CPU utilization as a percentage of the theoretical maximum during the
|
|
last thirty minutes - 1.3.6.1.4.1.232.11.2.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilHour
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.5
|
|
type: gauge
|
|
help: The CPU utilization as a percentage of the theoretical maximum during the
|
|
last hour - 1.3.6.1.4.1.232.11.2.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilHwLocation
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.6
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the CPU - 1.3.6.1.4.1.232.11.2.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.4.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.2
|
|
type: DisplayString
|
|
help: A description of the file system include the GUID. - 1.3.6.1.4.1.232.11.2.4.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysSpaceTotal
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.3
|
|
type: gauge
|
|
help: The file system size in megabytes - 1.3.6.1.4.1.232.11.2.4.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysSpaceUsed
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.4
|
|
type: gauge
|
|
help: The megabytes of file system space currently in use - 1.3.6.1.4.1.232.11.2.4.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysPercentSpaceUsed
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.5
|
|
type: gauge
|
|
help: The percent of file system space currently in use - 1.3.6.1.4.1.232.11.2.4.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysAllocUnitsTotal
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.6
|
|
type: gauge
|
|
help: The total number of files (directory entries) that can be stored on the
|
|
file system if a limit exists other than total space used - 1.3.6.1.4.1.232.11.2.4.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysAllocUnitsUsed
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.7
|
|
type: gauge
|
|
help: The number of files (directory entries) on this file system - 1.3.6.1.4.1.232.11.2.4.1.1.7
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysStatus
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.8
|
|
type: gauge
|
|
help: The Threshold Status - 1.3.6.1.4.1.232.11.2.4.1.1.8
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoFileSysShortDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.9
|
|
type: DisplayString
|
|
help: A description of the file system. - 1.3.6.1.4.1.232.11.2.4.1.1.9
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysCondition
|
|
oid: 1.3.6.1.4.1.232.11.2.4.2
|
|
type: gauge
|
|
help: The overall condition of File System Threshold - 1.3.6.1.4.1.232.11.2.4.2
|
|
enum_values:
|
|
1: unknown
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoIfPhysMapIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies this entry - 1.3.6.1.4.1.232.11.2.5.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapSlot
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.2
|
|
type: gauge
|
|
help: The number of the slot containing the physical hardware that implements
|
|
this interface - 1.3.6.1.4.1.232.11.2.5.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapIoBaseAddr
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.3
|
|
type: gauge
|
|
help: The base I/O address of the physical hardware that implements this interface.
|
|
- 1.3.6.1.4.1.232.11.2.5.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapIrq
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.4
|
|
type: gauge
|
|
help: The number of the IRQ (interrupt) used for this physical hardware interface
|
|
- 1.3.6.1.4.1.232.11.2.5.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapDma
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.5
|
|
type: gauge
|
|
help: The number of the DMA channel used for this physical hardware interface
|
|
- 1.3.6.1.4.1.232.11.2.5.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapMemBaseAddr
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.6
|
|
type: gauge
|
|
help: The base memory address used by this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapPort
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.7
|
|
type: gauge
|
|
help: The port number of the interface for multi-port NICs - 1.3.6.1.4.1.232.11.2.5.1.1.7
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapDuplexState
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.8
|
|
type: gauge
|
|
help: This variable describes the configured duplex state of the NIC. - 1.3.6.1.4.1.232.11.2.5.1.1.8
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: half
|
|
3: full
|
|
- name: cpqHoIfPhysMapCondition
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.9
|
|
type: gauge
|
|
help: The condition of this interface. - 1.3.6.1.4.1.232.11.2.5.1.1.9
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoIfPhysMapOverallCondition
|
|
oid: 1.3.6.1.4.1.232.11.2.5.2
|
|
type: gauge
|
|
help: The overall condition of all interfaces. - 1.3.6.1.4.1.232.11.2.5.2
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoSWRunningIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.6.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningName
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.2
|
|
type: DisplayString
|
|
help: The name of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.3
|
|
type: DisplayString
|
|
help: A description of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.4
|
|
type: DisplayString
|
|
help: The version of the software - 1.3.6.1.4.1.232.11.2.6.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningDate
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.5
|
|
type: OctetString
|
|
help: The software date - 1.3.6.1.4.1.232.11.2.6.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningMonitor
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.6
|
|
type: gauge
|
|
help: The user specified monitor option for a process. - 1.3.6.1.4.1.232.11.2.6.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: start
|
|
3: stop
|
|
4: startAndStop
|
|
5: count
|
|
6: startAndCount
|
|
7: countAndStop
|
|
8: startCountAndStop
|
|
- name: cpqHoSWRunningState
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.7
|
|
type: gauge
|
|
help: The current state of monitored process. - 1.3.6.1.4.1.232.11.2.6.1.1.7
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: started
|
|
3: stopped
|
|
- name: cpqHoSWRunningCount
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.8
|
|
type: gauge
|
|
help: For each process name, the number of instances of the process running on
|
|
the system is kept count of, in this variable. - 1.3.6.1.4.1.232.11.2.6.1.1.8
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningCountMin
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.9
|
|
type: gauge
|
|
help: This is the lower threshold on cpqHoSWRunningCount to be set by the user.
|
|
- 1.3.6.1.4.1.232.11.2.6.1.1.9
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningCountMax
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.10
|
|
type: gauge
|
|
help: This is the upper threshold on cpqHoSWRunningCount to be set by the user.
|
|
- 1.3.6.1.4.1.232.11.2.6.1.1.10
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningEventTime
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.11
|
|
type: OctetString
|
|
help: The system time at which the monitored event, as per cpqHoSWRunningMonitor,
|
|
last occurred - 1.3.6.1.4.1.232.11.2.6.1.1.11
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningStatus
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.12
|
|
type: gauge
|
|
help: The overall alarm state of the resources managed by the software, or the
|
|
software itself. - 1.3.6.1.4.1.232.11.2.6.1.1.12
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: normal
|
|
3: warning
|
|
4: minor
|
|
5: major
|
|
6: critical
|
|
7: disabled
|
|
- name: cpqHoSWRunningConfigStatus
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.13
|
|
type: gauge
|
|
help: The configuration state of the software - 1.3.6.1.4.1.232.11.2.6.1.1.13
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: starting
|
|
3: initialized
|
|
4: configured
|
|
5: operational
|
|
- name: cpqHoSWRunningIdentifier
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.14
|
|
type: DisplayString
|
|
help: The unique identifier of the sofware - 1.3.6.1.4.1.232.11.2.6.1.1.14
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningRedundancyMode
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.15
|
|
type: gauge
|
|
help: When the software is running in a high availability mode, the failover mode
|
|
of this instance of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.15
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: master
|
|
3: backup
|
|
4: slave
|
|
- name: cpqHoSwRunningTrapDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.6.2
|
|
type: DisplayString
|
|
help: The error message for a process monitor event. - 1.3.6.1.4.1.232.11.2.6.2
|
|
- name: cpqHoSwVerNextIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.7.1
|
|
type: gauge
|
|
help: The index of the next available entry in the cpqHoSwVer table - 1.3.6.1.4.1.232.11.2.7.1
|
|
- name: cpqHoSwVerIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies an entry in the cpqHoSwVer table. - 1.3.6.1.4.1.232.11.2.7.2.1.1
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerStatus
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.2
|
|
type: gauge
|
|
help: Status for the software item. - 1.3.6.1.4.1.232.11.2.7.2.1.2
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: loaded
|
|
3: notloaded
|
|
- name: cpqHoSwVerType
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.3
|
|
type: gauge
|
|
help: Type of software item. - 1.3.6.1.4.1.232.11.2.7.2.1.3
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: driver
|
|
3: agent
|
|
4: sysutil
|
|
5: application
|
|
6: keyfile
|
|
7: firmware
|
|
- name: cpqHoSwVerName
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.4
|
|
type: DisplayString
|
|
help: The name of this software item. - 1.3.6.1.4.1.232.11.2.7.2.1.4
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerDescription
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.5
|
|
type: DisplayString
|
|
help: The description of this software item. - 1.3.6.1.4.1.232.11.2.7.2.1.5
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerDate
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.6
|
|
type: OctetString
|
|
help: The date of the software item, if any - 1.3.6.1.4.1.232.11.2.7.2.1.6
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerLocation
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.7
|
|
type: DisplayString
|
|
help: The location of this software item on the server. - 1.3.6.1.4.1.232.11.2.7.2.1.7
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.8
|
|
type: DisplayString
|
|
help: An string that specifies the version of this item. - 1.3.6.1.4.1.232.11.2.7.2.1.8
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerVersionBinary
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.9
|
|
type: DisplayString
|
|
help: An string that specifies the version of this item based on the binary version
|
|
resource. - 1.3.6.1.4.1.232.11.2.7.2.1.9
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerAgentsVer
|
|
oid: 1.3.6.1.4.1.232.11.2.7.3
|
|
type: DisplayString
|
|
help: A string that specifies the version of the Insight Management Agents running
|
|
on the system. - 1.3.6.1.4.1.232.11.2.7.3
|
|
- name: cpqHoGenericData
|
|
oid: 1.3.6.1.4.1.232.11.2.8.1
|
|
type: DisplayString
|
|
help: Data for the generic trap. - 1.3.6.1.4.1.232.11.2.8.1
|
|
- name: cpqHoCriticalSoftwareUpdateData
|
|
oid: 1.3.6.1.4.1.232.11.2.8.2
|
|
type: DisplayString
|
|
help: Data for the Critical Software Update trap. - 1.3.6.1.4.1.232.11.2.8.2
|
|
- name: cpqHoSwPerfAppErrorDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.9.1
|
|
type: DisplayString
|
|
help: This string holds error information about the last application error that
|
|
occurred in the system. - 1.3.6.1.4.1.232.11.2.9.1
|
|
- name: cpqHoMibStatusArray
|
|
oid: 1.3.6.1.4.1.232.11.2.10.1
|
|
type: OctetString
|
|
help: The MIB Status Array is an array of MIB status structures - 1.3.6.1.4.1.232.11.2.10.1
|
|
- name: cpqHoConfigChangedDate
|
|
oid: 1.3.6.1.4.1.232.11.2.10.2
|
|
type: OctetString
|
|
help: The date/time when the agents were last loaded - 1.3.6.1.4.1.232.11.2.10.2
|
|
- name: cpqHoGUID
|
|
oid: 1.3.6.1.4.1.232.11.2.10.3
|
|
type: OctetString
|
|
help: The globally unique identifier of this physical server - 1.3.6.1.4.1.232.11.2.10.3
|
|
- name: cpqHoCodeServer
|
|
oid: 1.3.6.1.4.1.232.11.2.10.4
|
|
type: gauge
|
|
help: This item indicates how many code server shares are currently configured
|
|
on the system - 1.3.6.1.4.1.232.11.2.10.4
|
|
- name: cpqHoWebMgmtPort
|
|
oid: 1.3.6.1.4.1.232.11.2.10.5
|
|
type: gauge
|
|
help: This item indicates the port used by the Insight Web Agent - 1.3.6.1.4.1.232.11.2.10.5
|
|
- name: cpqHoGUIDCanonical
|
|
oid: 1.3.6.1.4.1.232.11.2.10.6
|
|
type: OctetString
|
|
help: The globally unique identifier in canonical format of this physical server
|
|
- 1.3.6.1.4.1.232.11.2.10.6
|
|
- name: cpqHoMibHealthStatusArray
|
|
oid: 1.3.6.1.4.1.232.11.2.10.7
|
|
type: OctetString
|
|
help: 'The MIB Health Status Array is an array of status values representing an
|
|
overall status in element 0 follwed by server and storage status values as follows:
|
|
Octet Element Field ======== ======= ========= 0 0 Aggregated Status of array
|
|
elements 1 1 Status of element 1 2 2 Status of element 2 - 1.3.6.1.4.1.232.11.2.10.7'
|
|
- name: cpqHoTrapFlags
|
|
oid: 1.3.6.1.4.1.232.11.2.11.1
|
|
type: gauge
|
|
help: The Trap Flags - 1.3.6.1.4.1.232.11.2.11.1
|
|
- name: cpqHoClientLastModified
|
|
oid: 1.3.6.1.4.1.232.11.2.12.1
|
|
type: OctetString
|
|
help: The date/time of the last modification to the client table - 1.3.6.1.4.1.232.11.2.12.1
|
|
- name: cpqHoClientDelete
|
|
oid: 1.3.6.1.4.1.232.11.2.12.2
|
|
type: DisplayString
|
|
help: Setting this variable to the name of a client in the client table will cause
|
|
that row in the table to be deleted - 1.3.6.1.4.1.232.11.2.12.2
|
|
- name: cpqHoClientIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.12.3.1.1
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientName
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.2
|
|
type: DisplayString
|
|
help: The Win95 machine name of this client. - 1.3.6.1.4.1.232.11.2.12.3.1.2
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientIpxAddress
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.3
|
|
type: OctetString
|
|
help: The IPX address for this client, all octets should be set to 0xff if this
|
|
machine does not support IPX - 1.3.6.1.4.1.232.11.2.12.3.1.3
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientIpAddress
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.4
|
|
type: InetAddressIPv4
|
|
help: The IP address for this client, all octets should be set to 0xff if this
|
|
machine does not support IP - 1.3.6.1.4.1.232.11.2.12.3.1.4
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientCommunity
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.5
|
|
type: DisplayString
|
|
help: A community name that can be used to query the client with SNMP - 1.3.6.1.4.1.232.11.2.12.3.1.5
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientID
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.6
|
|
type: OctetString
|
|
help: The unique identifier of this client. - 1.3.6.1.4.1.232.11.2.12.3.1.6
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoPhysicalMemorySize
|
|
oid: 1.3.6.1.4.1.232.11.2.13.1
|
|
type: gauge
|
|
help: Total amount of physical memory as seen by the OS (in megabytes) - 1.3.6.1.4.1.232.11.2.13.1
|
|
- name: cpqHoPhysicalMemoryFree
|
|
oid: 1.3.6.1.4.1.232.11.2.13.2
|
|
type: gauge
|
|
help: The amount of free physical memory (in megabytes) - 1.3.6.1.4.1.232.11.2.13.2
|
|
- name: cpqHoPagingMemorySize
|
|
oid: 1.3.6.1.4.1.232.11.2.13.3
|
|
type: gauge
|
|
help: Total virtual memory available from the OS (in megabytes) - 1.3.6.1.4.1.232.11.2.13.3
|
|
- name: cpqHoPagingMemoryFree
|
|
oid: 1.3.6.1.4.1.232.11.2.13.4
|
|
type: gauge
|
|
help: Available paging memory (in megabytes) - 1.3.6.1.4.1.232.11.2.13.4
|
|
- name: cpqHoBootPagingFileSize
|
|
oid: 1.3.6.1.4.1.232.11.2.13.5
|
|
type: DisplayString
|
|
help: The paging file size of the boot volume in the format xxxMB or xxxGB, where
|
|
xxx is the paging file size in that unit shown right after it - 1.3.6.1.4.1.232.11.2.13.5
|
|
- name: cpqHoBootPagingFileMinimumSize
|
|
oid: 1.3.6.1.4.1.232.11.2.13.6
|
|
type: DisplayString
|
|
help: Minimum paging file size of the boot volume required to save the memory
|
|
dump in the event of a system crash - 1.3.6.1.4.1.232.11.2.13.6
|
|
- name: cpqHoBootPagingFileVolumeFreeSpace
|
|
oid: 1.3.6.1.4.1.232.11.2.13.7
|
|
type: DisplayString
|
|
help: Free space of the boot volume required to save the memory dump in the event
|
|
of a system crash - 1.3.6.1.4.1.232.11.2.13.7
|
|
- name: cpqHoFwVerIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.1
|
|
type: gauge
|
|
help: Firmware Version Index - 1.3.6.1.4.1.232.11.2.14.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerCategory
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.2
|
|
type: gauge
|
|
help: Firmware Version Category. - 1.3.6.1.4.1.232.11.2.14.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: storage
|
|
3: nic
|
|
4: rib
|
|
5: system
|
|
- name: cpqHoFwVerDeviceType
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.3
|
|
type: gauge
|
|
help: Firmware Version Device Type. - 1.3.6.1.4.1.232.11.2.14.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internalArrayController
|
|
3: fibreArrayController
|
|
4: scsiController
|
|
5: fibreChannelTapeController
|
|
6: modularDataRouter
|
|
7: ideCdRomDrive
|
|
8: ideDiskDrive
|
|
9: scsiCdRom-ScsiAttached
|
|
10: scsiDiskDrive-ScsiAttached
|
|
11: scsiTapeDrive-ScsiAttached
|
|
12: scsiTapeLibrary-ScsiAttached
|
|
13: scsiDiskDrive-ArrayAttached
|
|
14: scsiTapeDrive-ArrayAttached
|
|
15: scsiTapeLibrary-ArrayAttached
|
|
16: scsiDiskDrive-FibreAttached
|
|
17: scsiTapeDrive-FibreAttached
|
|
18: scsiTapeLibrary-FibreAttached
|
|
19: scsiEnclosureBackplaneRom-ScsiAttached
|
|
20: scsiEnclosureBackplaneRom-ArrayAttached
|
|
21: scsiEnclosureBackplaneRom-FibreAttached
|
|
22: scsiEnclosureBackplaneRom-ra4x00
|
|
23: systemRom
|
|
24: networkInterfaceController
|
|
25: remoteInsightBoard
|
|
26: sasDiskDrive-SasAttached
|
|
27: sataDiskDrive-SataAttached
|
|
28: usbController
|
|
29: sasControllerAdapter
|
|
30: sataControllerAdapter
|
|
31: systemDevice
|
|
32: fibreChannelHba
|
|
33: convergedNetworkAdapter
|
|
34: ideController
|
|
- name: cpqHoFwVerDisplayName
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.4
|
|
type: DisplayString
|
|
help: Firmware Version Device Display Name - 1.3.6.1.4.1.232.11.2.14.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.5
|
|
type: DisplayString
|
|
help: Firmware Version - 1.3.6.1.4.1.232.11.2.14.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerLocation
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.6
|
|
type: DisplayString
|
|
help: Firmware Version Device Location - 1.3.6.1.4.1.232.11.2.14.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerXmlString
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.7
|
|
type: DisplayString
|
|
help: Firmware Version Xml String - 1.3.6.1.4.1.232.11.2.14.1.1.7
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerKeyString
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.8
|
|
type: DisplayString
|
|
help: Firmware Version Key String - 1.3.6.1.4.1.232.11.2.14.1.1.8
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerUpdateMethod
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.9
|
|
type: gauge
|
|
help: Firmware Version update method. - 1.3.6.1.4.1.232.11.2.14.1.1.9
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: noUpdate
|
|
3: softwareflash
|
|
4: replacePhysicalRom
|
|
- name: cpqHoHWInfoPlatform
|
|
oid: 1.3.6.1.4.1.232.11.2.15.1
|
|
type: gauge
|
|
help: Hardware platform type - 1.3.6.1.4.1.232.11.2.15.1
|
|
enum_values:
|
|
1: unknown
|
|
2: cellular
|
|
3: foundation
|
|
4: virtualMachine
|
|
5: serverBlade
|
|
- name: cpqPwrWarnType
|
|
oid: 1.3.6.1.4.1.232.11.2.16.1
|
|
type: DisplayString
|
|
help: Type of power reading on which the warning is based. - 1.3.6.1.4.1.232.11.2.16.1
|
|
- name: cpqPwrWarnThreshold
|
|
oid: 1.3.6.1.4.1.232.11.2.16.2
|
|
type: gauge
|
|
help: The threshold the power usage must exceed (in Watts). - 1.3.6.1.4.1.232.11.2.16.2
|
|
- name: cpqPwrWarnDuration
|
|
oid: 1.3.6.1.4.1.232.11.2.16.3
|
|
type: gauge
|
|
help: Duration that power usage must be exceeded before warning (in minutes).
|
|
- 1.3.6.1.4.1.232.11.2.16.3
|
|
- name: cpqSerialNum
|
|
oid: 1.3.6.1.4.1.232.11.2.16.4
|
|
type: DisplayString
|
|
help: Serial number of the server. - 1.3.6.1.4.1.232.11.2.16.4
|
|
- name: cpqServerUUID
|
|
oid: 1.3.6.1.4.1.232.11.2.16.5
|
|
type: DisplayString
|
|
help: Server UUID - 1.3.6.1.4.1.232.11.2.16.5
|
|
- name: cpqIdeMibRevMajor
|
|
oid: 1.3.6.1.4.1.232.14.1.1
|
|
type: gauge
|
|
help: The Major Revision level - 1.3.6.1.4.1.232.14.1.1
|
|
- name: cpqIdeMibRevMinor
|
|
oid: 1.3.6.1.4.1.232.14.1.2
|
|
type: gauge
|
|
help: The Minor Revision level - 1.3.6.1.4.1.232.14.1.2
|
|
- name: cpqIdeMibCondition
|
|
oid: 1.3.6.1.4.1.232.14.1.3
|
|
type: gauge
|
|
help: The overall condition - 1.3.6.1.4.1.232.14.1.3
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeOsCommonPollFreq
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.1
|
|
type: gauge
|
|
help: The Insight Agent`s polling frequency - 1.3.6.1.4.1.232.14.2.1.4.1
|
|
- name: cpqIdeOsCommonModuleIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.1
|
|
type: gauge
|
|
help: A unique index for this module description. - 1.3.6.1.4.1.232.14.2.1.4.2.1.1
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeOsCommonModuleName
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.2
|
|
type: DisplayString
|
|
help: The module name. - 1.3.6.1.4.1.232.14.2.1.4.2.1.2
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeOsCommonModuleVersion
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.3
|
|
type: DisplayString
|
|
help: The module version in XX.YY format - 1.3.6.1.4.1.232.14.2.1.4.2.1.3
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeOsCommonModuleDate
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.4
|
|
type: OctetString
|
|
help: The module date - 1.3.6.1.4.1.232.14.2.1.4.2.1.4
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeOsCommonModulePurpose
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.5
|
|
type: DisplayString
|
|
help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.14.2.1.4.2.1.5
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies each device - 1.3.6.1.4.1.232.14.2.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentModel
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.2
|
|
type: DisplayString
|
|
help: IDE Drive Model - 1.3.6.1.4.1.232.14.2.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentSerNum
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.3
|
|
type: DisplayString
|
|
help: IDE Drive Serial Number - 1.3.6.1.4.1.232.14.2.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentFWVers
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.4
|
|
type: DisplayString
|
|
help: IDE Firmware Version - 1.3.6.1.4.1.232.14.2.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.5
|
|
type: gauge
|
|
help: IDE Drive Condition - 1.3.6.1.4.1.232.14.2.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeIdentErrorNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.6
|
|
type: DisplayString
|
|
help: IDE Error Number - 1.3.6.1.4.1.232.14.2.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentType
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.7
|
|
type: gauge
|
|
help: IDE Device Type - 1.3.6.1.4.1.232.14.2.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: disk
|
|
3: tape
|
|
4: printer
|
|
5: processor
|
|
6: wormDrive
|
|
7: cd-rom
|
|
8: scanner
|
|
9: optical
|
|
10: jukeBox
|
|
11: commDev
|
|
- name: cpqIdeIdentTypeExtended
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.8
|
|
type: gauge
|
|
help: IDE Extended Device Type - 1.3.6.1.4.1.232.14.2.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: pdcd
|
|
3: removableDisk
|
|
- name: cpqIdeIdentCondition2
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.9
|
|
type: gauge
|
|
help: IDE Drive Condition - 1.3.6.1.4.1.232.14.2.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeIdentStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.10
|
|
type: gauge
|
|
help: IDE Drive Satus - 1.3.6.1.4.1.232.14.2.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: preFailureDegraded
|
|
4: ultraAtaDegraded
|
|
- name: cpqIdeIdentUltraAtaAvailability
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.11
|
|
type: gauge
|
|
help: This describes the availability of Ultra ATA transfers between this device
|
|
and the controller - 1.3.6.1.4.1.232.14.2.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: noNotSupportedByDeviceAndController
|
|
3: noNotSupportedByDevice
|
|
4: noNotSupportedByController
|
|
5: noDisabledInSetup
|
|
6: yesEnabledInSetup
|
|
- name: cpqIdeControllerIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerOverallCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.2
|
|
type: gauge
|
|
help: IDE Controller Overall Condition - 1.3.6.1.4.1.232.14.2.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeControllerModel
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.3
|
|
type: DisplayString
|
|
help: IDE Controller Model - 1.3.6.1.4.1.232.14.2.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerFwRev
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.4
|
|
type: DisplayString
|
|
help: IDE Controller Firmware Revision - 1.3.6.1.4.1.232.14.2.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerSlot
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.5
|
|
type: gauge
|
|
help: IDE Controller Slot - 1.3.6.1.4.1.232.14.2.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.6
|
|
type: gauge
|
|
help: IDE Channel Host Controller Status - 1.3.6.1.4.1.232.14.2.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
- name: cpqIdeControllerCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.7
|
|
type: gauge
|
|
help: IDE Controller Condition - 1.3.6.1.4.1.232.14.2.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeControllerSerialNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.8
|
|
type: DisplayString
|
|
help: IDE Controller Serial Number - 1.3.6.1.4.1.232.14.2.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerHwLocation
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.9
|
|
type: DisplayString
|
|
help: IDE Controller Hardware Location - 1.3.6.1.4.1.232.14.2.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerPciLocation
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.10
|
|
type: DisplayString
|
|
help: IDE Controller PCI Location - 1.3.6.1.4.1.232.14.2.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskControllerIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.4.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.2
|
|
type: gauge
|
|
help: An index that uniquely identifies each disk. - 1.3.6.1.4.1.232.14.2.4.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskModel
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.3
|
|
type: DisplayString
|
|
help: ATA Disk Model - 1.3.6.1.4.1.232.14.2.4.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskFwRev
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.4
|
|
type: DisplayString
|
|
help: ATA Disk Firmware Revision - 1.3.6.1.4.1.232.14.2.4.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskSerialNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.5
|
|
type: DisplayString
|
|
help: ATA Disk Serial Number - 1.3.6.1.4.1.232.14.2.4.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.6
|
|
type: gauge
|
|
help: ATA Disk Status - 1.3.6.1.4.1.232.14.2.4.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: smartError
|
|
4: failed
|
|
5: ssdWearOut
|
|
- name: cpqIdeAtaDiskCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.7
|
|
type: gauge
|
|
help: ATA Disk Condition - 1.3.6.1.4.1.232.14.2.4.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeAtaDiskCapacity
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.8
|
|
type: gauge
|
|
help: ATA Disk Capacity - 1.3.6.1.4.1.232.14.2.4.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskSmartEnabled
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.9
|
|
type: gauge
|
|
help: ATA Disk S.M.A.R.T Enabled? other(1) The agent cannot determine the state
|
|
of S.M.A.R.T - 1.3.6.1.4.1.232.14.2.4.1.1.9
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqIdeAtaDiskTransferMode
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.10
|
|
type: gauge
|
|
help: ATA Disk Transfer Mode - 1.3.6.1.4.1.232.14.2.4.1.1.10
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: pioMode0
|
|
3: pioMode1
|
|
4: pioMode2
|
|
5: pioMode3
|
|
6: pioMode4
|
|
7: dmaMode0
|
|
8: dmaMode1
|
|
9: dmaMode2
|
|
10: ultraDmaMode0
|
|
11: ultraDmaMode1
|
|
12: ultraDmaMode2
|
|
13: ultraDmaMode3
|
|
14: ultraDmaMode4
|
|
15: ultraDmaMode5
|
|
- name: cpqIdeAtaDiskChannel
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.11
|
|
type: gauge
|
|
help: ATA Disk Channel - 1.3.6.1.4.1.232.14.2.4.1.1.11
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: channel0
|
|
3: channel1
|
|
4: serial
|
|
- name: cpqIdeAtaDiskNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.12
|
|
type: gauge
|
|
help: ATA Disk Number - 1.3.6.1.4.1.232.14.2.4.1.1.12
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: device0
|
|
3: device1
|
|
4: sataDevice0
|
|
5: sataDevice1
|
|
6: sataDevice2
|
|
7: sataDevice3
|
|
8: sataDevice4
|
|
9: sataDevice5
|
|
10: sataDevice6
|
|
11: sataDevice7
|
|
21: bay1
|
|
22: bay2
|
|
23: bay3
|
|
24: bay4
|
|
25: bay5
|
|
26: bay6
|
|
27: bay7
|
|
28: bay8
|
|
29: bay9
|
|
30: bay10
|
|
31: bay11
|
|
32: bay12
|
|
33: bay13
|
|
34: bay14
|
|
- name: cpqIdeAtaDiskLogicalDriveMember
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.13
|
|
type: gauge
|
|
help: Logical Drive Membership? other(1) The agent cannot determine if the ATA
|
|
disk is part of a logical drive - 1.3.6.1.4.1.232.14.2.4.1.1.13
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqIdeAtaDiskIsSpare
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.14
|
|
type: gauge
|
|
help: ATA Disk Spare? other(1) The agent cannot determine if the ATA disk is a
|
|
spare - 1.3.6.1.4.1.232.14.2.4.1.1.14
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqIdeAtaDiskOsName
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.15
|
|
type: DisplayString
|
|
help: ATA Disk OS Name - 1.3.6.1.4.1.232.14.2.4.1.1.15
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskType
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.16
|
|
type: gauge
|
|
help: ATA Disk Type other(1) The agent cannot determine the disk type - 1.3.6.1.4.1.232.14.2.4.1.1.16
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ata
|
|
3: sata
|
|
- name: cpqIdeAtaDiskSataVersion
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.17
|
|
type: gauge
|
|
help: Physical Drive SATA Version - 1.3.6.1.4.1.232.14.2.4.1.1.17
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: sataOne
|
|
3: sataTwo
|
|
- name: cpqIdeAtaDiskMediaType
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.18
|
|
type: gauge
|
|
help: SATA Physical Drive Media Type - 1.3.6.1.4.1.232.14.2.4.1.1.18
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rotatingPlatters
|
|
3: solidState
|
|
- name: cpqIdeAtaDiskSSDWearStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.19
|
|
type: gauge
|
|
help: SATA Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.14.2.4.1.1.19
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: fiftySixDayThreshold
|
|
4: fivePercentThreshold
|
|
5: twoPercentThreshold
|
|
6: ssdWearOut
|
|
- name: cpqIdeAtaDiskPowerOnHours
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.20
|
|
type: counter
|
|
help: SATA Physical Drive Power On Hours - 1.3.6.1.4.1.232.14.2.4.1.1.20
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskSSDPercntEndrnceUsed
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.21
|
|
type: gauge
|
|
help: SATA Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.14.2.4.1.1.21
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskSSDEstTimeRemainingHours
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.22
|
|
type: counter
|
|
help: SATA Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.14.2.4.1.1.22
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskCurrTemperature
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.23
|
|
type: gauge
|
|
help: SATA Physical Drive Current Operating Temperature degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.23
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskTemperatureThreshold
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.24
|
|
type: gauge
|
|
help: SATA Physical Drive Maximum Operating Temperature in degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.24
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskMaximumOperatingTemp
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.25
|
|
type: gauge
|
|
help: SATA Physical Drive Maximum Operating Temperature, as specified by the manufacturer,
|
|
in degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.25
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskDestructiveOperatingTemp
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.26
|
|
type: gauge
|
|
help: SATA Physical Drive Destructive Operating Temperature, as specified by the
|
|
manufacturer, in degrees Celsius, which if exceeded can cause damage to the
|
|
drive - 1.3.6.1.4.1.232.14.2.4.1.1.26
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaEraseFailureType
|
|
oid: 1.3.6.1.4.1.232.14.2.4.2
|
|
type: gauge
|
|
help: The value specifies the secure erase status of SATA drive - 1.3.6.1.4.1.232.14.2.4.2
|
|
enum_values:
|
|
1: secureEraseFailed
|
|
2: secureEraseNotSupported
|
|
3: noEraseSupported
|
|
- name: cpqIdeAtapiDeviceControllerIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.5.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
- name: cpqIdeAtapiDeviceIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.2
|
|
type: gauge
|
|
help: An index that uniquely identifies each ATAPI device. - 1.3.6.1.4.1.232.14.2.5.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
- name: cpqIdeAtapiDeviceModel
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.3
|
|
type: DisplayString
|
|
help: ATAPI Device Model - 1.3.6.1.4.1.232.14.2.5.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
- name: cpqIdeAtapiDeviceFwRev
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.4
|
|
type: DisplayString
|
|
help: ATAPI Device Firmware Revision - 1.3.6.1.4.1.232.14.2.5.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
- name: cpqIdeAtapiDeviceType
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.5
|
|
type: gauge
|
|
help: ATAPI Device Type - 1.3.6.1.4.1.232.14.2.5.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: disk
|
|
3: tape
|
|
4: printer
|
|
5: processor
|
|
6: wormDrive
|
|
7: cd-rom
|
|
8: scanner
|
|
9: optical
|
|
10: jukeBox
|
|
11: commDev
|
|
- name: cpqIdeAtapiDeviceTypeExtended
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.6
|
|
type: gauge
|
|
help: ATAPI Extended Device Type - 1.3.6.1.4.1.232.14.2.5.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: pdcd
|
|
3: removableDisk
|
|
- name: cpqIdeAtapiDeviceChannel
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.7
|
|
type: gauge
|
|
help: ATAPI Device Channel - 1.3.6.1.4.1.232.14.2.5.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: channel0
|
|
3: channel1
|
|
- name: cpqIdeAtapiDeviceNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.8
|
|
type: gauge
|
|
help: ATAPI Device Number - 1.3.6.1.4.1.232.14.2.5.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: device0
|
|
3: device1
|
|
- name: cpqIdeLogicalDriveControllerIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.6.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.2
|
|
type: gauge
|
|
help: An index that uniquely identifies each logical drive. - 1.3.6.1.4.1.232.14.2.6.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveRaidLevel
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.3
|
|
type: gauge
|
|
help: IDE Logical Drive RAID Level - 1.3.6.1.4.1.232.14.2.6.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: raid0
|
|
3: raid1
|
|
4: raid0plus1
|
|
5: raid5
|
|
6: raid15
|
|
7: volume
|
|
- name: cpqIdeLogicalDriveCapacity
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.4
|
|
type: gauge
|
|
help: IDE Logical Drive Capacity - 1.3.6.1.4.1.232.14.2.6.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.5
|
|
type: gauge
|
|
help: IDE Logical Drive Status - 1.3.6.1.4.1.232.14.2.6.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: rebuilding
|
|
5: failed
|
|
- name: cpqIdeLogicalDriveCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.6
|
|
type: gauge
|
|
help: IDE Logical Drive Condition - 1.3.6.1.4.1.232.14.2.6.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeLogicalDriveDiskIds
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.7
|
|
type: OctetString
|
|
help: IDE Logical Drive Disk ID list - 1.3.6.1.4.1.232.14.2.6.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveStripeSize
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.8
|
|
type: gauge
|
|
help: IDE Logical Drive Stripe Size - 1.3.6.1.4.1.232.14.2.6.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveSpareIds
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.9
|
|
type: OctetString
|
|
help: IDE Logical Drive Spare ID list - 1.3.6.1.4.1.232.14.2.6.1.1.9
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveRebuildingDisk
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.10
|
|
type: gauge
|
|
help: IDE Logical Drive Rebuilding Disk - 1.3.6.1.4.1.232.14.2.6.1.1.10
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveOsName
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.11
|
|
type: DisplayString
|
|
help: IDE Logical Drive OS Name - 1.3.6.1.4.1.232.14.2.6.1.1.11
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.1
|
|
type: gauge
|
|
help: Array Controller Index - 1.3.6.1.4.1.232.3.2.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrModel
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.2
|
|
type: gauge
|
|
help: Array Controller Model - 1.3.6.1.4.1.232.3.2.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ida
|
|
3: idaExpansion
|
|
4: ida-2
|
|
5: smart
|
|
6: smart-2e
|
|
7: smart-2p
|
|
8: smart-2sl
|
|
9: smart-3100es
|
|
10: smart-3200
|
|
11: smart-2dh
|
|
12: smart-221
|
|
13: sa-4250es
|
|
14: sa-4200
|
|
15: sa-integrated
|
|
16: sa-431
|
|
17: sa-5300
|
|
18: raidLc2
|
|
19: sa-5i
|
|
20: sa-532
|
|
21: sa-5312
|
|
22: sa-641
|
|
23: sa-642
|
|
24: sa-6400
|
|
25: sa-6400em
|
|
26: sa-6i
|
|
27: sa-generic
|
|
29: sa-p600
|
|
30: sa-p400
|
|
31: sa-e200
|
|
32: sa-e200i
|
|
33: sa-p400i
|
|
34: sa-p800
|
|
35: sa-e500
|
|
36: sa-p700m
|
|
37: sa-p212
|
|
38: sa-p410
|
|
39: sa-p410i
|
|
40: sa-p411
|
|
41: sa-b110i
|
|
42: sa-p712m
|
|
43: sa-p711m
|
|
44: sa-p812
|
|
45: sw-1210m
|
|
46: sa-p220i
|
|
47: sa-p222
|
|
48: sa-p420
|
|
49: sa-p420i
|
|
50: sa-p421
|
|
51: sa-b320i
|
|
52: sa-p822
|
|
53: sa-p721m
|
|
54: sa-b120i
|
|
55: hps-1224
|
|
56: hps-1228
|
|
57: hps-1228m
|
|
58: sa-p822se
|
|
59: hps-1224e
|
|
60: hps-1228e
|
|
61: hps-1228em
|
|
62: sa-p230i
|
|
63: sa-p430i
|
|
64: sa-p430
|
|
65: sa-p431
|
|
66: sa-p731m
|
|
67: sa-p830i
|
|
68: sa-p830
|
|
69: sa-p831
|
|
70: sa-p530
|
|
71: sa-p531
|
|
72: sa-p244br
|
|
73: sa-p246br
|
|
74: sa-p440
|
|
75: sa-p440ar
|
|
76: sa-p441
|
|
77: sa-p741m
|
|
78: sa-p840
|
|
79: sa-p841
|
|
80: sh-h240ar
|
|
81: sh-h244br
|
|
82: sh-h240
|
|
83: sh-h241
|
|
84: sa-b140i
|
|
85: sh-generic
|
|
86: sa-p240nr
|
|
87: sh-h240nr
|
|
88: sa-p840ar
|
|
89: sa-p542d
|
|
90: s100i
|
|
91: e208i-p
|
|
92: e208i-a
|
|
93: e208i-c
|
|
94: e208e-p
|
|
95: p204i-b
|
|
96: p204i-c
|
|
97: p408i-p
|
|
98: p408i-a
|
|
99: p408e-p
|
|
100: p408i-c
|
|
101: p408e-m
|
|
102: p416ie-m
|
|
103: p816i-a
|
|
104: p408i-sb
|
|
- name: cpqDaCntlrFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.3
|
|
type: DisplayString
|
|
help: Array Controller Firmware Revision - 1.3.6.1.4.1.232.3.2.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrStndIntr
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.4
|
|
type: gauge
|
|
help: The status of the Standard Interface - 1.3.6.1.4.1.232.3.2.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: primary
|
|
3: secondary
|
|
4: disabled
|
|
5: unavailable
|
|
- name: cpqDaCntlrSlot
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.5
|
|
type: gauge
|
|
help: Array Controller Slot - 1.3.6.1.4.1.232.3.2.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.6
|
|
type: gauge
|
|
help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaCntlrProductRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.7
|
|
type: DisplayString
|
|
help: Array Controller Product Revision - 1.3.6.1.4.1.232.3.2.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrPartnerSlot
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.8
|
|
type: gauge
|
|
help: Array Controller Partner Slot - 1.3.6.1.4.1.232.3.2.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrCurrentRole
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.9
|
|
type: gauge
|
|
help: Array Controller Current Role - 1.3.6.1.4.1.232.3.2.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notDuplexed
|
|
3: active
|
|
4: backup
|
|
5: asymActiveActive
|
|
- name: cpqDaCntlrBoardStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.10
|
|
type: gauge
|
|
help: Array Controller Board Status - 1.3.6.1.4.1.232.3.2.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: generalFailure
|
|
4: cableProblem
|
|
5: poweredOff
|
|
6: cacheModuleMissing
|
|
- name: cpqDaCntlrPartnerBoardStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.11
|
|
type: gauge
|
|
help: Array Controller Partner Board Status - 1.3.6.1.4.1.232.3.2.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: generalFailure
|
|
4: cableProblem
|
|
5: poweredOff
|
|
- name: cpqDaCntlrBoardCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.12
|
|
type: gauge
|
|
help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.12
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaCntlrPartnerBoardCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.13
|
|
type: gauge
|
|
help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.13
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaCntlrDriveOwnership
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.14
|
|
type: gauge
|
|
help: Array Controller Drive Ownership - 1.3.6.1.4.1.232.3.2.2.1.1.14
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: owner
|
|
3: notOwner
|
|
- name: cpqDaCntlrSerialNumber
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.15
|
|
type: DisplayString
|
|
help: Array Controller Serial Number - 1.3.6.1.4.1.232.3.2.2.1.1.15
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrRedundancyType
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.16
|
|
type: gauge
|
|
help: Array Controller Redundancy Type - 1.3.6.1.4.1.232.3.2.2.1.1.16
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notRedundant
|
|
3: driverDuplexing
|
|
4: fwActiveStandby
|
|
5: fwPrimarySecondary
|
|
6: fwActiveActive
|
|
- name: cpqDaCntlrRedundancyError
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.17
|
|
type: gauge
|
|
help: Array Controller Redundancy Error - 1.3.6.1.4.1.232.3.2.2.1.1.17
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: noFailure
|
|
3: noRedundantController
|
|
4: differentHardware
|
|
5: noLink
|
|
6: differentFirmware
|
|
7: differentCache
|
|
8: otherCacheFailure
|
|
9: noDrives
|
|
10: otherNoDrives
|
|
11: unsupportedDrives
|
|
12: expandInProgress
|
|
- name: cpqDaCntlrAccessModuleStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.18
|
|
type: gauge
|
|
help: Array Controller RAID ADG Enabler Module Status - 1.3.6.1.4.1.232.3.2.2.1.1.18
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notPresent
|
|
4: badSignature
|
|
5: badChecksum
|
|
6: fullyFunctional
|
|
7: upgradeFirmware
|
|
- name: cpqDaCntlrDaughterBoardType
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.19
|
|
type: gauge
|
|
help: Array Controller Daughter Board Type - 1.3.6.1.4.1.232.3.2.2.1.1.19
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notPresent
|
|
4: scsiBoardPresent
|
|
5: fibreBoardPresent
|
|
6: arrayExpansionModulePresent
|
|
- name: cpqDaCntlrHwLocation
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.20
|
|
type: DisplayString
|
|
help: A text description of the hardware location of the controller - 1.3.6.1.4.1.232.3.2.2.1.1.20
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrNumberOfBuses
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.21
|
|
type: gauge
|
|
help: Array Controller Number of Buses - 1.3.6.1.4.1.232.3.2.2.1.1.21
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrBlinkTime
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.22
|
|
type: counter
|
|
help: Controller Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.2.1.1.22
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrRebuildPriority
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.23
|
|
type: gauge
|
|
help: Array Controller Rebuild Priority - 1.3.6.1.4.1.232.3.2.2.1.1.23
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: low
|
|
3: medium
|
|
4: high
|
|
5: mediumHigh
|
|
- name: cpqDaCntlrExpandPriority
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.24
|
|
type: gauge
|
|
help: Array Controller Expand Priority - 1.3.6.1.4.1.232.3.2.2.1.1.24
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: low
|
|
3: medium
|
|
4: high
|
|
- name: cpqDaCntlrNumberOfInternalPorts
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.25
|
|
type: gauge
|
|
help: Array Controller Number of Internal Ports - 1.3.6.1.4.1.232.3.2.2.1.1.25
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrNumberOfExternalPorts
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.26
|
|
type: gauge
|
|
help: Array Controller Number of External Ports - 1.3.6.1.4.1.232.3.2.2.1.1.26
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrDriveWriteCacheState
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.27
|
|
type: gauge
|
|
help: Array Controller Drive Write Cache State - 1.3.6.1.4.1.232.3.2.2.1.1.27
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: disabled
|
|
3: enabled
|
|
- name: cpqDaCntlrPartnerSerialNumber
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.28
|
|
type: DisplayString
|
|
help: Array Controller Partner Serial Number - 1.3.6.1.4.1.232.3.2.2.1.1.28
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrOptionRomRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.29
|
|
type: DisplayString
|
|
help: Array Controller Option ROM Revision - 1.3.6.1.4.1.232.3.2.2.1.1.29
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrHbaFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.30
|
|
type: DisplayString
|
|
help: Array Controller HBA Firmware Revision - 1.3.6.1.4.1.232.3.2.2.1.1.30
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrHBAModeOptionRomRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.31
|
|
type: DisplayString
|
|
help: Array Controller HBA Mode Option Rom Revision - 1.3.6.1.4.1.232.3.2.2.1.1.31
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrCurrentTemp
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.32
|
|
type: gauge
|
|
help: Array Controller Current Temperature - 1.3.6.1.4.1.232.3.2.2.1.1.32
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrLastLockupCode
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.33
|
|
type: gauge
|
|
help: Array Controller Last Lockup Code - 1.3.6.1.4.1.232.3.2.2.1.1.33
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrEncryptionStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.34
|
|
type: gauge
|
|
help: Array Controller Encryption Status - 1.3.6.1.4.1.232.3.2.2.1.1.34
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notEnabled
|
|
3: enabledLocalKeyMode
|
|
4: enabledRemoteKeyManagerMode
|
|
- name: cpqDaCntlrASICEncptSelfTestStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.35
|
|
type: gauge
|
|
help: Array Controller ASIC Encryption Self Test Status - 1.3.6.1.4.1.232.3.2.2.1.1.35
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: selfTestsPass
|
|
3: selfTestsFailed
|
|
- name: cpqDaCntlrEncryptCspNvramStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.36
|
|
type: gauge
|
|
help: Array Controller Encryption Critical Security Parameter NVRAM Status - 1.3.6.1.4.1.232.3.2.2.1.1.36
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: detectionFailed
|
|
- name: cpqDaCntlrEncryptCryptoOfficerPwdSetStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.37
|
|
type: gauge
|
|
help: Array Controller Encryption Crypto Officer Password Set Status - 1.3.6.1.4.1.232.3.2.2.1.1.37
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrEncryptCntlrPwdSetStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.38
|
|
type: gauge
|
|
help: Array Controller Encryption Controller Password Set Status - 1.3.6.1.4.1.232.3.2.2.1.1.38
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrEncryptCntlrPwdAvailStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.39
|
|
type: gauge
|
|
help: Array Controller Encryption Controller Password Availability Status - 1.3.6.1.4.1.232.3.2.2.1.1.39
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: passwordMissing
|
|
3: passwordActive
|
|
- name: cpqDaCntlrUnencryptedLogDrvCreationPolicy
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.40
|
|
type: gauge
|
|
help: Array Controller Unencrypted Logical Drive Creation Policy - 1.3.6.1.4.1.232.3.2.2.1.1.40
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrEncryptedLogDrvCreationPolicy
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.41
|
|
type: gauge
|
|
help: Array Controller Encrypted Logical Drive Creation Policy - 1.3.6.1.4.1.232.3.2.2.1.1.41
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrEncryptFWLockStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.42
|
|
type: gauge
|
|
help: Array Controller Encryption Firmware Lock Status - 1.3.6.1.4.1.232.3.2.2.1.1.42
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrOperatingMode
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.43
|
|
type: gauge
|
|
help: Array Controller Operating Mode - 1.3.6.1.4.1.232.3.2.2.1.1.43
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: smartArrayMode
|
|
3: smartHbaMode
|
|
4: mixedMode
|
|
- name: cpqDaLogDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.1
|
|
type: gauge
|
|
help: Drive Array Logical Drive Controller Index - 1.3.6.1.4.1.232.3.2.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.2
|
|
type: gauge
|
|
help: Drive Array Logical Drive Index - 1.3.6.1.4.1.232.3.2.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvFaultTol
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.3
|
|
type: gauge
|
|
help: Logical Drive Fault Tolerance - 1.3.6.1.4.1.232.3.2.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: none
|
|
3: mirroring
|
|
4: dataGuard
|
|
5: distribDataGuard
|
|
7: advancedDataGuard
|
|
8: raid50
|
|
9: raid60
|
|
10: raid1Adm
|
|
11: raid10Adm
|
|
12: raid10
|
|
- name: cpqDaLogDrvStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.4
|
|
type: gauge
|
|
help: Logical Drive Status - 1.3.6.1.4.1.232.3.2.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: unconfigured
|
|
5: recovering
|
|
6: readyForRebuild
|
|
7: rebuilding
|
|
8: wrongDrive
|
|
9: badConnect
|
|
10: overheating
|
|
11: shutdown
|
|
12: expanding
|
|
13: notAvailable
|
|
14: queuedForExpansion
|
|
15: multipathAccessDegraded
|
|
16: erasing
|
|
17: predictiveSpareRebuildReady
|
|
18: rapidParityInitInProgress
|
|
19: rapidParityInitPending
|
|
20: noAccessEncryptedNoCntlrKey
|
|
21: unencryptedToEncryptedInProgress
|
|
22: newLogDrvKeyRekeyInProgress
|
|
23: noAccessEncryptedCntlrEncryptnNotEnbld
|
|
24: unencryptedToEncryptedNotStarted
|
|
25: newLogDrvKeyRekeyRequestReceived
|
|
- name: cpqDaLogDrvAutoRel
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.5
|
|
type: gauge
|
|
help: Array Controller Logical Drive Auto-Reliability Delay - 1.3.6.1.4.1.232.3.2.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvRebuildBlks
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.6
|
|
type: counter
|
|
help: Logical Drive Rebuild Blocks Remaining - 1.3.6.1.4.1.232.3.2.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvHasAccel
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.7
|
|
type: gauge
|
|
help: Logical Drive Has Cache Module Board - 1.3.6.1.4.1.232.3.2.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unavailable
|
|
3: enabled
|
|
4: disabled
|
|
- name: cpqDaLogDrvAvailSpares
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.8
|
|
type: OctetString
|
|
help: Drive Array Logical Drive Available Spares - 1.3.6.1.4.1.232.3.2.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvSize
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.9
|
|
type: gauge
|
|
help: Logical Drive Size - 1.3.6.1.4.1.232.3.2.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvPhyDrvIDs
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.10
|
|
type: OctetString
|
|
help: Drive Array Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.3.2.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.11
|
|
type: gauge
|
|
help: The Logical Drive condition - 1.3.6.1.4.1.232.3.2.3.1.1.11
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaLogDrvPercentRebuild
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.12
|
|
type: gauge
|
|
help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.3.2.3.1.1.12
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvStripeSize
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.13
|
|
type: gauge
|
|
help: Logical Drive Stripe Size - 1.3.6.1.4.1.232.3.2.3.1.1.13
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvOsName
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.14
|
|
type: DisplayString
|
|
help: Logical Drive OS Name - 1.3.6.1.4.1.232.3.2.3.1.1.14
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvBlinkTime
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.15
|
|
type: counter
|
|
help: Logical Drive Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.3.1.1.15
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvSpareReplaceMap
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.16
|
|
type: OctetString
|
|
help: Logical Drive Spare To Replacement Drive Map - 1.3.6.1.4.1.232.3.2.3.1.1.16
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvRebuildingPhyDrv
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.17
|
|
type: gauge
|
|
help: Logical Drive Physical Drive Rebuilding Index - 1.3.6.1.4.1.232.3.2.3.1.1.17
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvMultipathAccess
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.18
|
|
type: gauge
|
|
help: Logical Drive Multi-path Access - 1.3.6.1.4.1.232.3.2.3.1.1.18
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notConfigured
|
|
4: pathRedundant
|
|
5: noRedundantPath
|
|
- name: cpqDaLogDrvNmbrOfParityGroups
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.19
|
|
type: gauge
|
|
help: Logical Drive Number Of Parity Groups - 1.3.6.1.4.1.232.3.2.3.1.1.19
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvSplitMirrorBackupLogDrv
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.20
|
|
type: gauge
|
|
help: Logical Drive Split Mirror Backup Logical Drive - 1.3.6.1.4.1.232.3.2.3.1.1.20
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: isNotBackupLogicalDrive
|
|
3: isBackupLogicalDrive
|
|
- name: cpqDaLogDrvCacheVolAccelAssocType
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.21
|
|
type: gauge
|
|
help: Logical Drive Cache Volume Accelerator Association Type - 1.3.6.1.4.1.232.3.2.3.1.1.21
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: nonMember
|
|
3: logicalDriveMember
|
|
4: cacheVolumeMember
|
|
- name: cpqDaLogDrvCacheVolIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.22
|
|
type: gauge
|
|
help: Logical Drive Cache Volume Index - 1.3.6.1.4.1.232.3.2.3.1.1.22
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvRPIPercentComplete
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.23
|
|
type: gauge
|
|
help: Logical Drive Rapid Parity Initialization Percent Complete - 1.3.6.1.4.1.232.3.2.3.1.1.23
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvSSDSmartPathStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.24
|
|
type: gauge
|
|
help: Logical Drive SSD Smart Path Status - 1.3.6.1.4.1.232.3.2.3.1.1.24
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: updateDriver
|
|
3: ssdSmartPathDisabled
|
|
4: ssdSmartPathEnabled
|
|
- name: cpqDaLogDrvEncryptionStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.25
|
|
type: gauge
|
|
help: Logical Drive Encryption Status - 1.3.6.1.4.1.232.3.2.3.1.1.25
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: encrypted
|
|
3: notEncrypted
|
|
- name: cpqDaPhyDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.1
|
|
type: gauge
|
|
help: Drive Array Physical Drive Controller Index - 1.3.6.1.4.1.232.3.2.5.1.1.1
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.2
|
|
type: gauge
|
|
help: Drive Array Physical Drive Index - 1.3.6.1.4.1.232.3.2.5.1.1.2
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvModel
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.3
|
|
type: DisplayString
|
|
help: Physical Drive Model - 1.3.6.1.4.1.232.3.2.5.1.1.3
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.4
|
|
type: DisplayString
|
|
help: Physical Drive Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.4
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBay
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.5
|
|
type: gauge
|
|
help: Physical Drive Bay Location - 1.3.6.1.4.1.232.3.2.5.1.1.5
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.6
|
|
type: gauge
|
|
help: Physical Drive Status - 1.3.6.1.4.1.232.3.2.5.1.1.6
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: predictiveFailure
|
|
5: erasing
|
|
6: eraseDone
|
|
7: eraseQueued
|
|
8: ssdWearOut
|
|
9: notAuthenticated
|
|
- name: cpqDaPhyDrvFactReallocs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.7
|
|
type: gauge
|
|
help: This shows the number of spare sectors available for remapping at the time
|
|
the physical drive was shipped - 1.3.6.1.4.1.232.3.2.5.1.1.7
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvUsedReallocs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.8
|
|
type: counter
|
|
help: Physical Drive Used Reallocated Sectors - 1.3.6.1.4.1.232.3.2.5.1.1.8
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvRefHours
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.9
|
|
type: counter
|
|
help: Reference Time in hours - 1.3.6.1.4.1.232.3.2.5.1.1.9
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHReads
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.10
|
|
type: counter
|
|
help: Sectors Read (high) - 1.3.6.1.4.1.232.3.2.5.1.1.10
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvReads
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.11
|
|
type: counter
|
|
help: Sectors Read (low) - 1.3.6.1.4.1.232.3.2.5.1.1.11
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHWrites
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.12
|
|
type: counter
|
|
help: Sectors Written (high) - 1.3.6.1.4.1.232.3.2.5.1.1.12
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvWrites
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.13
|
|
type: counter
|
|
help: Sectors Written (low) - 1.3.6.1.4.1.232.3.2.5.1.1.13
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHSeeks
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.14
|
|
type: counter
|
|
help: Total Seeks (high) - 1.3.6.1.4.1.232.3.2.5.1.1.14
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSeeks
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.15
|
|
type: counter
|
|
help: Total Seeks (low) - 1.3.6.1.4.1.232.3.2.5.1.1.15
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHardReadErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.16
|
|
type: counter
|
|
help: Hard Read Errors - 1.3.6.1.4.1.232.3.2.5.1.1.16
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvRecvReadErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.17
|
|
type: counter
|
|
help: Recovered Read Errors - 1.3.6.1.4.1.232.3.2.5.1.1.17
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHardWriteErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.18
|
|
type: counter
|
|
help: Hard Write Errors - 1.3.6.1.4.1.232.3.2.5.1.1.18
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvRecvWriteErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.19
|
|
type: counter
|
|
help: Recovered Write Errors - 1.3.6.1.4.1.232.3.2.5.1.1.19
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHSeekErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.20
|
|
type: counter
|
|
help: Seek Errors (High) - 1.3.6.1.4.1.232.3.2.5.1.1.20
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSeekErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.21
|
|
type: counter
|
|
help: Seek Errors (low) - 1.3.6.1.4.1.232.3.2.5.1.1.21
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSpinupTime
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.22
|
|
type: gauge
|
|
help: Spin up Time in tenths of seconds - 1.3.6.1.4.1.232.3.2.5.1.1.22
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFunctTest1
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.23
|
|
type: gauge
|
|
help: Functional Test 1 - 1.3.6.1.4.1.232.3.2.5.1.1.23
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFunctTest2
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.24
|
|
type: gauge
|
|
help: Functional Test 2 - 1.3.6.1.4.1.232.3.2.5.1.1.24
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFunctTest3
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.25
|
|
type: gauge
|
|
help: Functional Test 3 - 1.3.6.1.4.1.232.3.2.5.1.1.25
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvDrqTimeouts
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.26
|
|
type: counter
|
|
help: DRQ Timeouts - 1.3.6.1.4.1.232.3.2.5.1.1.26
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvOtherTimeouts
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.27
|
|
type: counter
|
|
help: Other Timeouts - 1.3.6.1.4.1.232.3.2.5.1.1.27
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSpinupRetries
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.28
|
|
type: counter
|
|
help: Spin up Retries - 1.3.6.1.4.1.232.3.2.5.1.1.28
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBadRecvReads
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.29
|
|
type: counter
|
|
help: Recovery Failed (Bad) Read Error - 1.3.6.1.4.1.232.3.2.5.1.1.29
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBadRecvWrites
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.30
|
|
type: counter
|
|
help: Recovery Failed (Bad) Write Error - 1.3.6.1.4.1.232.3.2.5.1.1.30
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFormatErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.31
|
|
type: counter
|
|
help: Format Error - 1.3.6.1.4.1.232.3.2.5.1.1.31
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvPostErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.32
|
|
type: counter
|
|
help: Power On Self Test (Post) Error - 1.3.6.1.4.1.232.3.2.5.1.1.32
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvNotReadyErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.33
|
|
type: counter
|
|
help: Drive Not Ready Errors - 1.3.6.1.4.1.232.3.2.5.1.1.33
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvReallocAborts
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.34
|
|
type: counter
|
|
help: Physical Drive Reallocation Aborts - 1.3.6.1.4.1.232.3.2.5.1.1.34
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvThreshPassed
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.35
|
|
type: gauge
|
|
help: Physical Drive Factory Threshold Passed (Exceeded) - 1.3.6.1.4.1.232.3.2.5.1.1.35
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: "false"
|
|
2: "true"
|
|
- name: cpqDaPhyDrvHasMonInfo
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.36
|
|
type: gauge
|
|
help: Physical Drive Has Monitor Information - 1.3.6.1.4.1.232.3.2.5.1.1.36
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: "false"
|
|
2: "true"
|
|
- name: cpqDaPhyDrvCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.37
|
|
type: gauge
|
|
help: The condition of the device - 1.3.6.1.4.1.232.3.2.5.1.1.37
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaPhyDrvHotPlugs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.38
|
|
type: counter
|
|
help: Physical Drive Hot Plug Count - 1.3.6.1.4.1.232.3.2.5.1.1.38
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvMediaErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.39
|
|
type: counter
|
|
help: Physical Drive Media Failure Count - 1.3.6.1.4.1.232.3.2.5.1.1.39
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHardwareErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.40
|
|
type: counter
|
|
help: Physical Drive Hardware Error Count - 1.3.6.1.4.1.232.3.2.5.1.1.40
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvAbortedCmds
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.41
|
|
type: counter
|
|
help: Physical Drive Aborted Command Failures - 1.3.6.1.4.1.232.3.2.5.1.1.41
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSpinUpErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.42
|
|
type: counter
|
|
help: Physical Drive Spin-Up Failure Count - 1.3.6.1.4.1.232.3.2.5.1.1.42
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBadTargetErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.43
|
|
type: counter
|
|
help: Physical Drive Bad Target Count - 1.3.6.1.4.1.232.3.2.5.1.1.43
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvLocation
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.44
|
|
type: gauge
|
|
help: Drive Physical Location - 1.3.6.1.4.1.232.3.2.5.1.1.44
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
4: proLiant
|
|
- name: cpqDaPhyDrvSize
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.45
|
|
type: gauge
|
|
help: Physical Drive Size in MB - 1.3.6.1.4.1.232.3.2.5.1.1.45
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBusFaults
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.46
|
|
type: counter
|
|
help: Physical Drive Bus Fault Count - 1.3.6.1.4.1.232.3.2.5.1.1.46
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvIrqDeglitches
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.47
|
|
type: counter
|
|
help: Physical Drive IRQ Deglitch Count - 1.3.6.1.4.1.232.3.2.5.1.1.47
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHotPlug
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.48
|
|
type: gauge
|
|
help: Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.3.2.5.1.1.48
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: hotPlug
|
|
3: nonHotPlug
|
|
- name: cpqDaPhyDrvPlacement
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.49
|
|
type: gauge
|
|
help: Physical Drive Placement - 1.3.6.1.4.1.232.3.2.5.1.1.49
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
- name: cpqDaPhyDrvBusNumber
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.50
|
|
type: gauge
|
|
help: Physical Drive SCSI Bus Number - 1.3.6.1.4.1.232.3.2.5.1.1.50
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSerialNum
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.51
|
|
type: DisplayString
|
|
help: Physical Drive Serial Number - 1.3.6.1.4.1.232.3.2.5.1.1.51
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvPreFailMonitoring
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.52
|
|
type: gauge
|
|
help: Drive Array Physical Drive Predictive Failure Monitoring - 1.3.6.1.4.1.232.3.2.5.1.1.52
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notAvailable
|
|
3: available
|
|
- name: cpqDaPhyDrvCurrentWidth
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.53
|
|
type: gauge
|
|
help: Drive Array Physical Drive Current Width - 1.3.6.1.4.1.232.3.2.5.1.1.53
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: narrow
|
|
3: wide16
|
|
- name: cpqDaPhyDrvCurrentSpeed
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.54
|
|
type: gauge
|
|
help: Drive Array Physical Drive Current Data Transfer Speed - 1.3.6.1.4.1.232.3.2.5.1.1.54
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: asynchronous
|
|
3: fast
|
|
4: ultra
|
|
5: ultra2
|
|
6: ultra3
|
|
7: ultra320
|
|
- name: cpqDaPhyDrvFailureCode
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.55
|
|
type: gauge
|
|
help: Drive Array Physical Drive Failure Code - 1.3.6.1.4.1.232.3.2.5.1.1.55
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBlinkTime
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.56
|
|
type: counter
|
|
help: Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.5.1.1.56
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSmartStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.57
|
|
type: gauge
|
|
help: Physical Drive S.M.A.R.T Status - 1.3.6.1.4.1.232.3.2.5.1.1.57
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: replaceDrive
|
|
4: replaceDriveSSDWearOut
|
|
- name: cpqDaPhyDrvConfigurationStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.58
|
|
type: gauge
|
|
help: Physical Drive Configuration Status - 1.3.6.1.4.1.232.3.2.5.1.1.58
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: configured
|
|
3: notConfigured
|
|
- name: cpqDaPhyDrvRotationalSpeed
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.59
|
|
type: gauge
|
|
help: Drive Array Physical Drive Rotational Speed - 1.3.6.1.4.1.232.3.2.5.1.1.59
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rpm7200
|
|
3: rpm10K
|
|
4: rpm15K
|
|
5: rpmSsd
|
|
- name: cpqDaPhyDrvType
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.60
|
|
type: gauge
|
|
help: Physical Drive Type - 1.3.6.1.4.1.232.3.2.5.1.1.60
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: parallelScsi
|
|
3: sata
|
|
4: sas
|
|
- name: cpqDaPhyDrvSataVersion
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.61
|
|
type: gauge
|
|
help: Physical Drive SATA Version - 1.3.6.1.4.1.232.3.2.5.1.1.61
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: sataOne
|
|
3: sataTwo
|
|
- name: cpqDaPhyDrvHostConnector
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.62
|
|
type: DisplayString
|
|
help: Physical Drive Host Connector - 1.3.6.1.4.1.232.3.2.5.1.1.62
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBoxOnConnector
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.63
|
|
type: gauge
|
|
help: Physical Drive Box on Connector - 1.3.6.1.4.1.232.3.2.5.1.1.63
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvLocationString
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.64
|
|
type: DisplayString
|
|
help: Physical Drive Location String - 1.3.6.1.4.1.232.3.2.5.1.1.64
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvNegotiatedLinkRate
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.65
|
|
type: gauge
|
|
help: Drive Array Physical Drive Negotiated Link Rate - 1.3.6.1.4.1.232.3.2.5.1.1.65
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rate-1-5
|
|
3: rate-3-0
|
|
4: rate-6-0
|
|
5: rate-12-0
|
|
- name: cpqDaPhyDrvNcqSupport
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.66
|
|
type: gauge
|
|
help: Drive Array Physical Drive Native Command Queueing - 1.3.6.1.4.1.232.3.2.5.1.1.66
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: noControllerSupport
|
|
3: noDriveSupport
|
|
4: ncqDisabled
|
|
5: ncqEnabled
|
|
- name: cpqDaPhyDrvPhyCount
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.67
|
|
type: gauge
|
|
help: Drive Array Physical Drive PHY Count - 1.3.6.1.4.1.232.3.2.5.1.1.67
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvMultipathAccess
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.68
|
|
type: gauge
|
|
help: Drive Array Physical Drive Multi-path Access Status - 1.3.6.1.4.1.232.3.2.5.1.1.68
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notConfigured
|
|
4: pathRedundant
|
|
5: noRedundantPath
|
|
6: driveFailed
|
|
- name: cpqDaPhyDrvMediaType
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.69
|
|
type: gauge
|
|
help: Drive Array Physical Drive Media Type - 1.3.6.1.4.1.232.3.2.5.1.1.69
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rotatingPlatters
|
|
3: solidState
|
|
4: smr
|
|
- name: cpqDaPhyDrvCurrentTemperature
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.70
|
|
type: gauge
|
|
help: Drive Array Physical Drive Current Temperature - 1.3.6.1.4.1.232.3.2.5.1.1.70
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvTemperatureThreshold
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.71
|
|
type: gauge
|
|
help: Drive Array Physical Drive Temperature Threshold - 1.3.6.1.4.1.232.3.2.5.1.1.71
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvMaximumTemperature
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.72
|
|
type: gauge
|
|
help: Drive Array Physical Drive Maximum Temperature - 1.3.6.1.4.1.232.3.2.5.1.1.72
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSSDWearStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.73
|
|
type: gauge
|
|
help: Drive Array Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.3.2.5.1.1.73
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: fiftySixDayThreshold
|
|
4: fivePercentThreshold
|
|
5: twoPercentThreshold
|
|
6: ssdWearOut
|
|
- name: cpqDaPhyDrvPowerOnHours
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.74
|
|
type: counter
|
|
help: Drive Array Physical Drive Power On Hours - 1.3.6.1.4.1.232.3.2.5.1.1.74
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSSDPercntEndrnceUsed
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.75
|
|
type: gauge
|
|
help: Drive Array Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.3.2.5.1.1.75
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSSDEstTimeRemainingHours
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.76
|
|
type: counter
|
|
help: Drive Array Physical Drive Solid State Estimated Time Remaining In Hours
|
|
- 1.3.6.1.4.1.232.3.2.5.1.1.76
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvAuthenticationStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.77
|
|
type: gauge
|
|
help: Drive Array Physical Drive Authentication Status - 1.3.6.1.4.1.232.3.2.5.1.1.77
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: authenticationFailed
|
|
4: authenticationPassed
|
|
- name: cpqDaPhyDrvSmartCarrierAppFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.78
|
|
type: gauge
|
|
help: Physical Drive Smart Carrier Application Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.78
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSmartCarrierBootldrFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.79
|
|
type: gauge
|
|
help: Physical Drive Smart Carrier Bootloader Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.79
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvEncryptionStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.80
|
|
type: gauge
|
|
help: Physical Drive Encryption Status - 1.3.6.1.4.1.232.3.2.5.1.1.80
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: encrypted
|
|
3: notEncrypted
|
|
- name: cpqScsiMibRevMajor
|
|
oid: 1.3.6.1.4.1.232.5.1.1
|
|
type: gauge
|
|
help: The Major Revision level - 1.3.6.1.4.1.232.5.1.1
|
|
- name: cpqScsiMibRevMinor
|
|
oid: 1.3.6.1.4.1.232.5.1.2
|
|
type: gauge
|
|
help: The Minor Revision level - 1.3.6.1.4.1.232.5.1.2
|
|
- name: cpqScsiMibCondition
|
|
oid: 1.3.6.1.4.1.232.5.1.3
|
|
type: gauge
|
|
help: The overall condition - 1.3.6.1.4.1.232.5.1.3
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqScsiNw3xDriverName
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.1
|
|
type: DisplayString
|
|
help: SCSI Drive Device Driver Name - 1.3.6.1.4.1.232.5.2.1.1.1
|
|
- name: cpqScsiNw3xDriverVers
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.2
|
|
type: DisplayString
|
|
help: SCSI Drive Device Driver Version - 1.3.6.1.4.1.232.5.2.1.1.2
|
|
- name: cpqScsiNw3xDriverPollType
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.3
|
|
type: gauge
|
|
help: SCSI Drive Device Driver Poll Type - 1.3.6.1.4.1.232.5.2.1.1.3
|
|
enum_values:
|
|
1: other
|
|
2: polled
|
|
3: demand
|
|
- name: cpqScsiNw3xDriverPollTime
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.4
|
|
type: gauge
|
|
help: SCSI Drive Device Driver Poll Time - 1.3.6.1.4.1.232.5.2.1.1.4
|
|
- name: cpqScsiNw3xCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.1
|
|
type: gauge
|
|
help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.1.1.5.1.1
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.2
|
|
type: gauge
|
|
help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.5.1.2
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xXptDesc
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.3
|
|
type: DisplayString
|
|
help: SCSI XPT Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.3
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xXptVers
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.4
|
|
type: DisplayString
|
|
help: SCSI XPT Version - 1.3.6.1.4.1.232.5.2.1.1.5.1.4
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xSimDesc
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.5
|
|
type: DisplayString
|
|
help: SCSI SIM Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.5
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xSimVers
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.6
|
|
type: DisplayString
|
|
help: SCSI SIM Version - 1.3.6.1.4.1.232.5.2.1.1.5.1.6
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xHbaDesc
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.7
|
|
type: DisplayString
|
|
help: SCSI HBA Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.7
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xStatCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.1
|
|
type: gauge
|
|
help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.1
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xStatBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.2
|
|
type: gauge
|
|
help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.2
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xStatLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.3
|
|
type: gauge
|
|
help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.3
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xTotalReads
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.4
|
|
type: counter
|
|
help: SCSI Logical Drive Total Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.4
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xTotalWrites
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.5
|
|
type: counter
|
|
help: SCSI Logical Drive Total Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.5
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xCorrReads
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.6
|
|
type: counter
|
|
help: SCSI Logical Drive Corrected Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.6
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xCorrWrites
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.7
|
|
type: counter
|
|
help: SCSI Logical Drive Corrected Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.7
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xFatalReads
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.8
|
|
type: counter
|
|
help: SCSI Logical Drive Fatal Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.8
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xFatalWrites
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.9
|
|
type: counter
|
|
help: SCSI Logical Drive Fatal Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.9
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xVolCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.1
|
|
type: gauge
|
|
help: SCSI Cntlr Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.1
|
|
indexes:
|
|
- labelname: cpqScsiNw3xVolCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xVolBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.2
|
|
type: gauge
|
|
help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.2
|
|
indexes:
|
|
- labelname: cpqScsiNw3xVolCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xVolLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.3
|
|
type: gauge
|
|
help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.3
|
|
indexes:
|
|
- labelname: cpqScsiNw3xVolCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xVolMap
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.4
|
|
type: OctetString
|
|
help: SCSI Drive Volume Map - 1.3.6.1.4.1.232.5.2.1.1.7.1.4
|
|
indexes:
|
|
- labelname: cpqScsiNw3xVolCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonPollFreq
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.1
|
|
type: gauge
|
|
help: The agent`s polling frequency - 1.3.6.1.4.1.232.5.2.1.4.1
|
|
- name: cpqScsiOsCommonModuleIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.1
|
|
type: gauge
|
|
help: A unique index for this module description. - 1.3.6.1.4.1.232.5.2.1.4.2.1.1
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonModuleName
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.2
|
|
type: DisplayString
|
|
help: The module name. - 1.3.6.1.4.1.232.5.2.1.4.2.1.2
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonModuleVersion
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.3
|
|
type: DisplayString
|
|
help: The module version in XX.YY format - 1.3.6.1.4.1.232.5.2.1.4.2.1.3
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonModuleDate
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.4
|
|
type: OctetString
|
|
help: The module date - 1.3.6.1.4.1.232.5.2.1.4.2.1.4
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonModulePurpose
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.5
|
|
type: DisplayString
|
|
help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.5.2.1.4.2.1.5
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.1
|
|
type: gauge
|
|
help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.2
|
|
type: gauge
|
|
help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrModel
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.3
|
|
type: gauge
|
|
help: SCSI Controller Model - 1.3.6.1.4.1.232.5.2.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: cpqs710
|
|
3: cpqs94
|
|
4: cpqs810p
|
|
5: cpqs825e
|
|
6: cpqs825p
|
|
7: cpqs974p
|
|
8: cpqs875p
|
|
9: extended
|
|
10: cpqs895p
|
|
11: cpqs896p
|
|
12: cpqa789x
|
|
13: cpqs876t
|
|
14: hpu320
|
|
15: hpu320r
|
|
16: generic
|
|
17: hp1u320g2
|
|
18: hp1u320g1
|
|
19: hpSc11Xe
|
|
- name: cpqScsiCntlrFWVers
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.4
|
|
type: DisplayString
|
|
help: SCSI Controller Firmware Version - 1.3.6.1.4.1.232.5.2.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrSWVers
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.5
|
|
type: DisplayString
|
|
help: SCSI Controller Software Version - 1.3.6.1.4.1.232.5.2.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrSlot
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.6
|
|
type: gauge
|
|
help: SCSI Controller Slot - 1.3.6.1.4.1.232.5.2.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrStatus
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.7
|
|
type: gauge
|
|
help: SCSI Controller Status - 1.3.6.1.4.1.232.5.2.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
- name: cpqScsiCntlrHardResets
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.8
|
|
type: counter
|
|
help: SCSI Controller Hard Resets - 1.3.6.1.4.1.232.5.2.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrSoftResets
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.9
|
|
type: counter
|
|
help: SCSI Controller Soft Resets - 1.3.6.1.4.1.232.5.2.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrTimeouts
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.10
|
|
type: counter
|
|
help: SCSI Controller Time-outs - 1.3.6.1.4.1.232.5.2.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrBaseIOAddr
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.11
|
|
type: gauge
|
|
help: SCSI Controller Base I/O Address - 1.3.6.1.4.1.232.5.2.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrCondition
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.12
|
|
type: gauge
|
|
help: SCSI Controller Condition - 1.3.6.1.4.1.232.5.2.2.1.1.12
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqScsiCntlrSerialNum
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.13
|
|
type: DisplayString
|
|
help: SCSI Controller Serial Number - 1.3.6.1.4.1.232.5.2.2.1.1.13
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrBusWidth
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.14
|
|
type: gauge
|
|
help: SCSI Controller Data Bus Width - 1.3.6.1.4.1.232.5.2.2.1.1.14
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: narrow
|
|
3: wide16
|
|
- name: cpqScsiCntlrModelExtended
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.15
|
|
type: DisplayString
|
|
help: SCSI Controller Model Name - 1.3.6.1.4.1.232.5.2.2.1.1.15
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrHwLocation
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.16
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the SCSI controller - 1.3.6.1.4.1.232.5.2.2.1.1.16
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrPciLocation
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.17
|
|
type: DisplayString
|
|
help: A string designating the PCI device location for the controller, following
|
|
the format DDDD:BB:DD.F, where DDDD is the PCI domain number, BB is the PCI
|
|
bus number, DD is the PCI device number, and F is the PCI function number -
|
|
1.3.6.1.4.1.232.5.2.2.1.1.17
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.1
|
|
type: gauge
|
|
help: SCSI Logical Drive Controller Index - 1.3.6.1.4.1.232.5.2.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.2
|
|
type: gauge
|
|
help: SCSI Logical Drive Bus Index - 1.3.6.1.4.1.232.5.2.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.3
|
|
type: gauge
|
|
help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvFaultTol
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.4
|
|
type: gauge
|
|
help: SCSI Logical Drive Fault Tolerance - 1.3.6.1.4.1.232.5.2.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: none
|
|
3: mirroring
|
|
4: dataGuard
|
|
5: distribDataGuard
|
|
6: enhancedMirroring
|
|
- name: cpqScsiLogDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.5
|
|
type: gauge
|
|
help: SCSI Logical Drive Status - 1.3.6.1.4.1.232.5.2.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: unconfigured
|
|
5: recovering
|
|
6: readyForRebuild
|
|
7: rebuilding
|
|
8: wrongDrive
|
|
9: badConnect
|
|
10: degraded
|
|
11: disabled
|
|
- name: cpqScsiLogDrvSize
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.6
|
|
type: gauge
|
|
help: SCSI Logical Drive Size - 1.3.6.1.4.1.232.5.2.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvPhyDrvIDs
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.7
|
|
type: OctetString
|
|
help: SCSI Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.5.2.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.8
|
|
type: gauge
|
|
help: SCSI Logical Drive Condition - 1.3.6.1.4.1.232.5.2.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqScsiLogDrvStripeSize
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.9
|
|
type: gauge
|
|
help: Logical Drive Stripe Size - 1.3.6.1.4.1.232.5.2.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvAvailSpares
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.10
|
|
type: OctetString
|
|
help: SCSI Logical Drive Available Spares - 1.3.6.1.4.1.232.5.2.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvPercentRebuild
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.11
|
|
type: gauge
|
|
help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.5.2.3.1.1.11
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvOsName
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.12
|
|
type: DisplayString
|
|
help: Logical Drive OS Name - 1.3.6.1.4.1.232.5.2.3.1.1.12
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.1
|
|
type: gauge
|
|
help: SCSI Physical Drive Controller Index - 1.3.6.1.4.1.232.5.2.4.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.2
|
|
type: gauge
|
|
help: SCSI Physical Drive Bus Index - 1.3.6.1.4.1.232.5.2.4.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.3
|
|
type: gauge
|
|
help: SCSI Physical Drive Index - 1.3.6.1.4.1.232.5.2.4.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvModel
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.4
|
|
type: DisplayString
|
|
help: SCSI Physical Drive Model - 1.3.6.1.4.1.232.5.2.4.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvFWRev
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.5
|
|
type: DisplayString
|
|
help: SCSI Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.2.4.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvVendor
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.6
|
|
type: DisplayString
|
|
help: SCSI Physical Drive Vendor - 1.3.6.1.4.1.232.5.2.4.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvSize
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.7
|
|
type: gauge
|
|
help: SCSI Physical Drive Size in MB - 1.3.6.1.4.1.232.5.2.4.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvScsiID
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.8
|
|
type: gauge
|
|
help: SCSI Physical Drive SCSI ID - 1.3.6.1.4.1.232.5.2.4.1.1.8
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.9
|
|
type: gauge
|
|
help: SCSI Physical Drive Status - 1.3.6.1.4.1.232.5.2.4.1.1.9
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: notConfigured
|
|
5: badCable
|
|
6: missingWasOk
|
|
7: missingWasFailed
|
|
8: predictiveFailure
|
|
9: missingWasPredictiveFailure
|
|
10: offline
|
|
11: missingWasOffline
|
|
12: hardError
|
|
- name: cpqScsiPhyDrvServiceHours
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.10
|
|
type: counter
|
|
help: SCSI Physical Drive Service Time in hours - 1.3.6.1.4.1.232.5.2.4.1.1.10
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHighReadSectors
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.11
|
|
type: counter
|
|
help: SCSI Physical Drive Sectors Read (high) - 1.3.6.1.4.1.232.5.2.4.1.1.11
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvLowReadSectors
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.12
|
|
type: counter
|
|
help: SCSI Physical Drive Sectors Read (low) - 1.3.6.1.4.1.232.5.2.4.1.1.12
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHighWriteSectors
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.13
|
|
type: counter
|
|
help: SCSI Physical Drive Sectors Written (high) - 1.3.6.1.4.1.232.5.2.4.1.1.13
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvLowWriteSectors
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.14
|
|
type: counter
|
|
help: SCSI Physical Drive Sectors Written (low) - 1.3.6.1.4.1.232.5.2.4.1.1.14
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHardReadErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.15
|
|
type: counter
|
|
help: SCSI Physical Drive Hard Read Errors - 1.3.6.1.4.1.232.5.2.4.1.1.15
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHardWriteErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.16
|
|
type: counter
|
|
help: SCSI Physical Drive Hard Write Errors - 1.3.6.1.4.1.232.5.2.4.1.1.16
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvEccCorrReads
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.17
|
|
type: counter
|
|
help: SCSI Physical Drive ECC Corrected Read Errors (high) - 1.3.6.1.4.1.232.5.2.4.1.1.17
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvRecvReadErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.18
|
|
type: counter
|
|
help: SCSI Physical Drive Recovered Read Errors - 1.3.6.1.4.1.232.5.2.4.1.1.18
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvRecvWriteErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.19
|
|
type: counter
|
|
help: SCSI Physical Drive Recovered Write Errors - 1.3.6.1.4.1.232.5.2.4.1.1.19
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvSeekErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.20
|
|
type: counter
|
|
help: SCSI Physical Drive Seek Errors - 1.3.6.1.4.1.232.5.2.4.1.1.20
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvSpinupTime
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.21
|
|
type: gauge
|
|
help: SCSI Physical Drive Spin up Time (tenths of seconds) - 1.3.6.1.4.1.232.5.2.4.1.1.21
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvUsedReallocs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.22
|
|
type: counter
|
|
help: SCSI Physical Drive Used Reallocation Sectors - 1.3.6.1.4.1.232.5.2.4.1.1.22
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvTimeouts
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.23
|
|
type: counter
|
|
help: SCSI Physical Drive Time-out Errors - 1.3.6.1.4.1.232.5.2.4.1.1.23
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvPostErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.24
|
|
type: counter
|
|
help: SCSI Physical Drive Power On Self Test (POST) Errors - 1.3.6.1.4.1.232.5.2.4.1.1.24
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvPostErrCode
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.25
|
|
type: gauge
|
|
help: SCSI Physical Drive Last POST Error Code - 1.3.6.1.4.1.232.5.2.4.1.1.25
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.26
|
|
type: gauge
|
|
help: SCSI Physical Drive Condition - 1.3.6.1.4.1.232.5.2.4.1.1.26
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqScsiPhyDrvFuncTest1
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.27
|
|
type: gauge
|
|
help: SCSI Physical Drive Functional Test 1 - 1.3.6.1.4.1.232.5.2.4.1.1.27
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvFuncTest2
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.28
|
|
type: gauge
|
|
help: SCSI Physical Drive Functional Test 2 - 1.3.6.1.4.1.232.5.2.4.1.1.28
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvStatsPreserved
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.29
|
|
type: gauge
|
|
help: SCSI Physical Drive Statistics Preservation Method - 1.3.6.1.4.1.232.5.2.4.1.1.29
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: inNVRAM
|
|
3: onDisk
|
|
4: noCPUSupport
|
|
5: noFreeNVRAM
|
|
6: noDrvSupport
|
|
7: noSoftwareSupport
|
|
8: statsNotSupported
|
|
- name: cpqScsiPhyDrvSerialNum
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.30
|
|
type: DisplayString
|
|
help: SCSI Physical Drive Serial Number - 1.3.6.1.4.1.232.5.2.4.1.1.30
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvLocation
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.31
|
|
type: gauge
|
|
help: SCSI Physical Drive Location - 1.3.6.1.4.1.232.5.2.4.1.1.31
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: proliant
|
|
- name: cpqScsiPhyDrvParent
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.32
|
|
type: gauge
|
|
help: SCSI Physical Drive Parent - 1.3.6.1.4.1.232.5.2.4.1.1.32
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvSectorSize
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.33
|
|
type: gauge
|
|
help: SCSI Physical Drive Sector Size in Bytes - 1.3.6.1.4.1.232.5.2.4.1.1.33
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHotPlug
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.34
|
|
type: gauge
|
|
help: SCSI Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.2.4.1.1.34
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: hotPlug
|
|
3: nonHotPlug
|
|
- name: cpqScsiPhyDrvPlacement
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.35
|
|
type: gauge
|
|
help: SCSI Physical Drive Placement - 1.3.6.1.4.1.232.5.2.4.1.1.35
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
- name: cpqScsiPhyDrvPreFailMonitoring
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.36
|
|
type: gauge
|
|
help: SCSI Physical Drive Predictive Failure Monitoring - 1.3.6.1.4.1.232.5.2.4.1.1.36
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notAvailable
|
|
3: available
|
|
- name: cpqScsiPhyDrvOsName
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.37
|
|
type: DisplayString
|
|
help: Physical Drive OS Name - 1.3.6.1.4.1.232.5.2.4.1.1.37
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvRotationalSpeed
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.38
|
|
type: gauge
|
|
help: SCSI Physical Drive Rotational Speed - 1.3.6.1.4.1.232.5.2.4.1.1.38
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rpm7200
|
|
3: rpm10K
|
|
4: rpm15K
|
|
- name: cpqScsiPhyDrvMemberLogDrv
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.39
|
|
type: gauge
|
|
help: The Physical Drive is a Member of a Logical Drive - 1.3.6.1.4.1.232.5.2.4.1.1.39
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: member
|
|
3: spare
|
|
4: nonMember
|
|
- name: cpqScsiTargetCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.1
|
|
type: gauge
|
|
help: SCSI Target Controller Index - 1.3.6.1.4.1.232.5.2.5.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.2
|
|
type: gauge
|
|
help: SCSI Target Bus Index - 1.3.6.1.4.1.232.5.2.5.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.3
|
|
type: gauge
|
|
help: SCSI Target Device Index - 1.3.6.1.4.1.232.5.2.5.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetType
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.4
|
|
type: gauge
|
|
help: SCSI Device Type - 1.3.6.1.4.1.232.5.2.5.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: disk
|
|
3: tape
|
|
4: printer
|
|
5: processor
|
|
6: wormDrive
|
|
7: cd-rom
|
|
8: scanner
|
|
9: optical
|
|
10: jukeBox
|
|
11: commDev
|
|
- name: cpqScsiTargetModel
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.5
|
|
type: DisplayString
|
|
help: SCSI Device Model - 1.3.6.1.4.1.232.5.2.5.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetFWRev
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.6
|
|
type: DisplayString
|
|
help: SCSI Device Firmware Revision - 1.3.6.1.4.1.232.5.2.5.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetVendor
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.7
|
|
type: DisplayString
|
|
help: SCSI Device Vendor - 1.3.6.1.4.1.232.5.2.5.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetParityErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.8
|
|
type: counter
|
|
help: SCSI Device Bus Parity Errors - 1.3.6.1.4.1.232.5.2.5.1.1.8
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetPhaseErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.9
|
|
type: counter
|
|
help: SCSI Device Bus Phase Errors - 1.3.6.1.4.1.232.5.2.5.1.1.9
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetSelectTimeouts
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.10
|
|
type: counter
|
|
help: SCSI Device Bus Select Time-outs - 1.3.6.1.4.1.232.5.2.5.1.1.10
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetMsgRejects
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.11
|
|
type: counter
|
|
help: SCSI Device Bus Message Rejects - 1.3.6.1.4.1.232.5.2.5.1.1.11
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetNegPeriod
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.12
|
|
type: gauge
|
|
help: SCSI Device Negotiated Period - 1.3.6.1.4.1.232.5.2.5.1.1.12
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetLocation
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.13
|
|
type: gauge
|
|
help: SCSI Device Location - 1.3.6.1.4.1.232.5.2.5.1.1.13
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: proliant
|
|
- name: cpqScsiTargetNegSpeed
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.14
|
|
type: gauge
|
|
help: SCSI Device Negotiated Speed - 1.3.6.1.4.1.232.5.2.5.1.1.14
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetPhysWidth
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.15
|
|
type: gauge
|
|
help: SCSI Device Data Bus Physical Width - 1.3.6.1.4.1.232.5.2.5.1.1.15
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: narrow
|
|
3: wide16
|
|
- name: cpqScsiTargetNegWidth
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.16
|
|
type: gauge
|
|
help: SCSI Device Data Bus Negotiated Width - 1.3.6.1.4.1.232.5.2.5.1.1.16
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetTypeExtended
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.17
|
|
type: gauge
|
|
help: SCSI Extended Device Type - 1.3.6.1.4.1.232.5.2.5.1.1.17
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: pdcd
|
|
3: removableDisk
|
|
4: dltAutoloader
|
|
5: cdJukebox
|
|
6: cr3500
|
|
7: autoloader
|
|
- name: cpqScsiTargetCurrentSpeed
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.18
|
|
type: gauge
|
|
help: SCSI Device Current Data Transfer Speed - 1.3.6.1.4.1.232.5.2.5.1.1.18
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: asynchronous
|
|
3: fast
|
|
4: ultra
|
|
5: ultra2
|
|
6: ultra3
|
|
7: scsi1
|
|
8: ultra4
|
|
- name: cpqScsiCdDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.1
|
|
type: gauge
|
|
help: SCSI CD-ROM Drive Controller Index - 1.3.6.1.4.1.232.5.2.6.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.2
|
|
type: gauge
|
|
help: SCSI CD-ROM Drive Bus Index - 1.3.6.1.4.1.232.5.2.6.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.3
|
|
type: gauge
|
|
help: SCSI CD-ROM Drive Index - 1.3.6.1.4.1.232.5.2.6.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.4
|
|
type: gauge
|
|
help: SCSI CD-ROM Drive Logical Unit Index - 1.3.6.1.4.1.232.5.2.6.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvModel
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.5
|
|
type: DisplayString
|
|
help: SCSI CD Device Model - 1.3.6.1.4.1.232.5.2.6.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvVendor
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.6
|
|
type: DisplayString
|
|
help: SCSI CD Drive Vendor - 1.3.6.1.4.1.232.5.2.6.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvFwRev
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.7
|
|
type: DisplayString
|
|
help: SCSI CD-ROM Firmware Revision - 1.3.6.1.4.1.232.5.2.6.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.1
|
|
type: gauge
|
|
help: SCSI CD Library Controller Index - 1.3.6.1.4.1.232.5.2.6.2.1.1
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.2
|
|
type: gauge
|
|
help: SCSI CD Library Bus Index - 1.3.6.1.4.1.232.5.2.6.2.1.2
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.3
|
|
type: gauge
|
|
help: SCSI CD Library Device Index - 1.3.6.1.4.1.232.5.2.6.2.1.3
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.4
|
|
type: gauge
|
|
help: SCSI CD Library Logical Unit Index - 1.3.6.1.4.1.232.5.2.6.2.1.4
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryCondition
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.5
|
|
type: gauge
|
|
help: CD Library Condition - 1.3.6.1.4.1.232.5.2.6.2.1.5
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqCdLibraryStatus
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.6
|
|
type: gauge
|
|
help: CD Library Status - 1.3.6.1.4.1.232.5.2.6.2.1.6
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: offline
|
|
- name: cpqCdLibraryModel
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.7
|
|
type: DisplayString
|
|
help: SCSI CD Library Device Model - 1.3.6.1.4.1.232.5.2.6.2.1.7
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryVendor
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.8
|
|
type: DisplayString
|
|
help: SCSI CD Library Vendor - 1.3.6.1.4.1.232.5.2.6.2.1.8
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibrarySerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.9
|
|
type: DisplayString
|
|
help: CD Library Serial Number - 1.3.6.1.4.1.232.5.2.6.2.1.9
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryDriveList
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.10
|
|
type: OctetString
|
|
help: CD Library Drive List This is a data structure containing the list of CD
|
|
drive ids that are present in this library - 1.3.6.1.4.1.232.5.2.6.2.1.10
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryFwRev
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.11
|
|
type: DisplayString
|
|
help: SCSI CD Library Firmware Revision - 1.3.6.1.4.1.232.5.2.6.2.1.11
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryFwSubtype
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.12
|
|
type: gauge
|
|
help: SCSI CD library Firmware Subtype - 1.3.6.1.4.1.232.5.2.6.2.1.12
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqScsiTrapPkts
|
|
oid: 1.3.6.1.4.1.232.5.3.1
|
|
type: counter
|
|
help: The total number of trap packets issued by the SCSI enterprise since the
|
|
instrument agent was loaded. - 1.3.6.1.4.1.232.5.3.1
|
|
- name: cpqScsiTrapLogMaxSize
|
|
oid: 1.3.6.1.4.1.232.5.3.2
|
|
type: gauge
|
|
help: The maximum number of entries that will currently be kept in the trap log
|
|
- 1.3.6.1.4.1.232.5.3.2
|
|
- name: cpqScsiTrapLogIndex
|
|
oid: 1.3.6.1.4.1.232.5.3.3.1.1
|
|
type: gauge
|
|
help: The value of this object uniquely identifies this trapLogEntry at this time
|
|
- 1.3.6.1.4.1.232.5.3.3.1.1
|
|
indexes:
|
|
- labelname: cpqScsiTrapLogIndex
|
|
type: gauge
|
|
- name: cpqScsiTrapType
|
|
oid: 1.3.6.1.4.1.232.5.3.3.1.2
|
|
type: gauge
|
|
help: The type of the trap event that this entry describes - 1.3.6.1.4.1.232.5.3.3.1.2
|
|
indexes:
|
|
- labelname: cpqScsiTrapLogIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: cpqScsiCntlrStatusChange
|
|
2: cpqScsiLogDrvStatusChange
|
|
3: cpqScsiPhyDrvStatusChange
|
|
5001: cpqScsi2CntlrStatusChange
|
|
5002: cpqScsi2LogDrvStatusChange
|
|
5003: cpqScsi2PhyDrvStatusChange
|
|
- name: cpqScsiTrapTime
|
|
oid: 1.3.6.1.4.1.232.5.3.3.1.3
|
|
type: OctetString
|
|
help: The time of the trap event that this entry describes - 1.3.6.1.4.1.232.5.3.3.1.3
|
|
indexes:
|
|
- labelname: cpqScsiTrapLogIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.1
|
|
type: gauge
|
|
help: Tape Physical Drive Controller Index - 1.3.6.1.4.1.232.5.4.1.1.1.1
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.2
|
|
type: gauge
|
|
help: Tape Physical Drive Bus Index - 1.3.6.1.4.1.232.5.4.1.1.1.2
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.3
|
|
type: gauge
|
|
help: Tape Physical Drive Index - 1.3.6.1.4.1.232.5.4.1.1.1.3
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.4
|
|
type: gauge
|
|
help: Tape Physical Drive Logical Unit Index - 1.3.6.1.4.1.232.5.4.1.1.1.4
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvType
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.5
|
|
type: gauge
|
|
help: Tape Device Type - 1.3.6.1.4.1.232.5.4.1.1.1.5
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: cpqDat4-16
|
|
3: cpqDatAuto
|
|
4: cpqDat2-8
|
|
5: cpqDlt10-20
|
|
6: cpqDlt20-40
|
|
7: cpqDlt15-30
|
|
8: cpqDlt35-70
|
|
9: cpqDat4-8
|
|
10: cpqSlr4-8
|
|
11: cpqDat12-24
|
|
12: cpqDatAuto12-24
|
|
13: cpqMlr16-32
|
|
14: cpqAit35
|
|
15: cpqAit50
|
|
16: cpqDat20-40
|
|
17: cpqDlt40-80
|
|
18: cpqDatAuto20-40
|
|
19: cpqSuperDlt1
|
|
20: cpqAit35Lvd
|
|
21: cpqCompaq
|
|
- name: cpqTapePhyDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.6
|
|
type: gauge
|
|
help: Tape Physical Drive Status - 1.3.6.1.4.1.232.5.4.1.1.1.6
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqTapePhyDrvMagSize
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.7
|
|
type: gauge
|
|
help: Tape Physical Drive Magazine Size - 1.3.6.1.4.1.232.5.4.1.1.1.7
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.8
|
|
type: DisplayString
|
|
help: Tape Physical Drive Serial Number - 1.3.6.1.4.1.232.5.4.1.1.1.8
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvCleanReq
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.9
|
|
type: gauge
|
|
help: Tape Physical Drive Cleaning Required Status - 1.3.6.1.4.1.232.5.4.1.1.1.9
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqTapePhyDrvCleanTapeRepl
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.10
|
|
type: gauge
|
|
help: Tape Physical Drive Cleaning Tape Replacement Status - 1.3.6.1.4.1.232.5.4.1.1.1.10
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqTapePhyDrvFwSubtype
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.11
|
|
type: gauge
|
|
help: Tape Physical Drive Firmware Subtype - 1.3.6.1.4.1.232.5.4.1.1.1.11
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvName
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.12
|
|
type: DisplayString
|
|
help: Tape Physical Drive Name - 1.3.6.1.4.1.232.5.4.1.1.1.12
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvCleanTapeCount
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.13
|
|
type: gauge
|
|
help: Tape Physical Drive Cleaning Tape Count - 1.3.6.1.4.1.232.5.4.1.1.1.13
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvFwRev
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.14
|
|
type: DisplayString
|
|
help: Tape Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.4.1.1.1.14
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.15
|
|
type: gauge
|
|
help: Tape Physical Drive Status - 1.3.6.1.4.1.232.5.4.1.1.1.15
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
4: failed
|
|
5: offline
|
|
6: missingWasOk
|
|
7: missingWasFailed
|
|
8: missingWasOffline
|
|
- name: cpqTapePhyDrvHotPlug
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.16
|
|
type: gauge
|
|
help: Tape Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.4.1.1.1.16
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: hotPlug
|
|
3: nonHotPlug
|
|
- name: cpqTapePhyDrvPlacement
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.17
|
|
type: gauge
|
|
help: Tape Physical Drive Placement - 1.3.6.1.4.1.232.5.4.1.1.1.17
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
- name: cpqTapePhyDrvLibraryDrive
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.18
|
|
type: gauge
|
|
help: Tape Physical Drive Library Drive - 1.3.6.1.4.1.232.5.4.1.1.1.18
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqTapePhyDrvLoaderName
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.19
|
|
type: DisplayString
|
|
help: Tape Autoloader Name - 1.3.6.1.4.1.232.5.4.1.1.1.19
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvLoaderFwRev
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.20
|
|
type: DisplayString
|
|
help: Tape Autoloader Firmware Revision - 1.3.6.1.4.1.232.5.4.1.1.1.20
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvLoaderSerialNum
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.21
|
|
type: DisplayString
|
|
help: Tape Autoloader Serial Number - 1.3.6.1.4.1.232.5.4.1.1.1.21
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.1
|
|
type: gauge
|
|
help: SCSI Counters Controller Index - 1.3.6.1.4.1.232.5.4.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.2
|
|
type: gauge
|
|
help: SCSI Counters Bus Index - 1.3.6.1.4.1.232.5.4.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.3
|
|
type: gauge
|
|
help: SCSI Counters Device Index - 1.3.6.1.4.1.232.5.4.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.4
|
|
type: gauge
|
|
help: SCSI Counters Logical Unit Index - 1.3.6.1.4.1.232.5.4.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersReWrites
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.5
|
|
type: counter
|
|
help: Tape Device Re-write count - 1.3.6.1.4.1.232.5.4.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersReReads
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.6
|
|
type: counter
|
|
help: Tape Device Re-read count - 1.3.6.1.4.1.232.5.4.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersTotalErrors
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.7
|
|
type: counter
|
|
help: Tape Device Total Errors - 1.3.6.1.4.1.232.5.4.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersTotalUncorrectable
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.8
|
|
type: counter
|
|
help: Tape Device Total Uncorrectable Errors - 1.3.6.1.4.1.232.5.4.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersTotalBytes
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.9
|
|
type: counter
|
|
help: Tape Device Total Bytes - 1.3.6.1.4.1.232.5.4.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.1
|
|
type: gauge
|
|
help: SCSI Library Controller Index - 1.3.6.1.4.1.232.5.4.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.2
|
|
type: gauge
|
|
help: SCSI Library Bus Index - 1.3.6.1.4.1.232.5.4.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.3
|
|
type: gauge
|
|
help: SCSI Library Device Index - 1.3.6.1.4.1.232.5.4.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.4
|
|
type: gauge
|
|
help: SCSI Library Logical Unit Index - 1.3.6.1.4.1.232.5.4.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryCondition
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.5
|
|
type: gauge
|
|
help: Tape Library Status - 1.3.6.1.4.1.232.5.4.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqTapeLibraryStatus
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.6
|
|
type: gauge
|
|
help: Error code returned by the last library error. - 1.3.6.1.4.1.232.5.4.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryDoorStatus
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.7
|
|
type: gauge
|
|
help: Status of the library door - 1.3.6.1.4.1.232.5.4.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: closed
|
|
3: open
|
|
4: notSupported
|
|
- name: cpqTapeLibraryStatHours
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.8
|
|
type: counter
|
|
help: The number of hours of operation for the library. - 1.3.6.1.4.1.232.5.4.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryStatMoves
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.9
|
|
type: counter
|
|
help: The number of tape moves for the library loader arm. - 1.3.6.1.4.1.232.5.4.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryName
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.10
|
|
type: DisplayString
|
|
help: Tape Library Name. - 1.3.6.1.4.1.232.5.4.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibrarySerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.11
|
|
type: DisplayString
|
|
help: Tape Library Serial Number - 1.3.6.1.4.1.232.5.4.3.1.1.11
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryDriveList
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.12
|
|
type: OctetString
|
|
help: Tape Library Drive List This is a data structure containing the list of
|
|
tape drive ids that are present in this library - 1.3.6.1.4.1.232.5.4.3.1.1.12
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryState
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.13
|
|
type: gauge
|
|
help: Tape Library Status - 1.3.6.1.4.1.232.5.4.3.1.1.13
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
5: offline
|
|
- name: cpqTapeLibraryTemperature
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.14
|
|
type: gauge
|
|
help: Tape Library Temperature Status - 1.3.6.1.4.1.232.5.4.3.1.1.14
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: ok
|
|
4: safeTempExceeded
|
|
5: maxTempExceeded
|
|
- name: cpqTapeLibraryRedundancy
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.15
|
|
type: gauge
|
|
help: Tape Library Redundancy Status - 1.3.6.1.4.1.232.5.4.3.1.1.15
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: capable
|
|
4: notCapable
|
|
5: active
|
|
- name: cpqTapeLibraryHotSwap
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.16
|
|
type: gauge
|
|
help: Tape Library Hot Swap Status - 1.3.6.1.4.1.232.5.4.3.1.1.16
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: capable
|
|
4: notCapable
|
|
- name: cpqTapeLibraryFwRev
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.17
|
|
type: DisplayString
|
|
help: Tape Library Firmware Revision - 1.3.6.1.4.1.232.5.4.3.1.1.17
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryTapeList
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.18
|
|
type: OctetString
|
|
help: Tape Library Drive List This is a data structure containing the list of
|
|
tape drive ids that are present in this library - 1.3.6.1.4.1.232.5.4.3.1.1.18
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqSasHbaIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.1
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Index - 1.3.6.1.4.1.232.5.5.1.1.1.1
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaHwLocation
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.2
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter Hardware Location - 1.3.6.1.4.1.232.5.5.1.1.1.2
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaModel
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.3
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Model - 1.3.6.1.4.1.232.5.5.1.1.1.3
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: generic
|
|
3: sas8int
|
|
4: sas4int
|
|
5: sasSc44Ge
|
|
6: sasSc40Ge
|
|
7: sasSc08Ge
|
|
8: sasSc08e
|
|
9: sasH220i
|
|
10: sasH221
|
|
11: sasH210i
|
|
12: sasH220
|
|
13: sasH222
|
|
14: sasP824ip
|
|
- name: cpqSasHbaStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.4
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Status - 1.3.6.1.4.1.232.5.5.1.1.1.4
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
- name: cpqSasHbaCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.5
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Condition - 1.3.6.1.4.1.232.5.5.1.1.1.5
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasHbaOverallCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.6
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Overall Condition - 1.3.6.1.4.1.232.5.5.1.1.1.6
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasHbaSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.7
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter Serial Number - 1.3.6.1.4.1.232.5.5.1.1.1.7
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaFwVersion
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.8
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter Firmware Version - 1.3.6.1.4.1.232.5.5.1.1.1.8
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaBiosVersion
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.9
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter BIOS Version - 1.3.6.1.4.1.232.5.5.1.1.1.9
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaPciLocation
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.10
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter PCI Location - 1.3.6.1.4.1.232.5.5.1.1.1.10
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvHbaIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.1
|
|
type: gauge
|
|
help: SAS Physical Drive HBA Index - 1.3.6.1.4.1.232.5.5.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.2
|
|
type: gauge
|
|
help: SAS Physical Drive Index - 1.3.6.1.4.1.232.5.5.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvLocationString
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.3
|
|
type: DisplayString
|
|
help: SAS Physical Drive Location String - 1.3.6.1.4.1.232.5.5.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvModel
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.4
|
|
type: DisplayString
|
|
help: SAS Physical Drive Model - 1.3.6.1.4.1.232.5.5.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.5
|
|
type: gauge
|
|
help: SAS Physical Drive Status - 1.3.6.1.4.1.232.5.5.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: predictiveFailure
|
|
4: offline
|
|
5: failed
|
|
6: missingWasOk
|
|
7: missingWasPredictiveFailure
|
|
8: missingWasOffline
|
|
9: missingWasFailed
|
|
10: ssdWearOut
|
|
11: missingWasSSDWearOut
|
|
12: notAuthenticated
|
|
13: missingWasNotAuthenticated
|
|
- name: cpqSasPhyDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.6
|
|
type: gauge
|
|
help: SAS Physical Drive Condition - 1.3.6.1.4.1.232.5.5.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasPhyDrvFWRev
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.7
|
|
type: DisplayString
|
|
help: SAS Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSize
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.8
|
|
type: gauge
|
|
help: SAS Physical Drive Size in MB - 1.3.6.1.4.1.232.5.5.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvUsedReallocs
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.9
|
|
type: counter
|
|
help: SAS Physical Drive Used Reallocation Sectors - 1.3.6.1.4.1.232.5.5.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.10
|
|
type: DisplayString
|
|
help: SAS Physical Drive Serial Number - 1.3.6.1.4.1.232.5.5.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvMemberLogDrv
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.11
|
|
type: gauge
|
|
help: The Physical Drive is a Member of a Logical Drive - 1.3.6.1.4.1.232.5.5.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: member
|
|
3: spare
|
|
4: nonMember
|
|
- name: cpqSasPhyDrvRotationalSpeed
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.12
|
|
type: gauge
|
|
help: SAS Physical Drive Rotational Speed - 1.3.6.1.4.1.232.5.5.2.1.1.12
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rpm7200
|
|
3: rpm10K
|
|
4: rpm15K
|
|
5: rpmSsd
|
|
- name: cpqSasPhyDrvOsName
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.13
|
|
type: DisplayString
|
|
help: SAS Physical Drive OS Name - 1.3.6.1.4.1.232.5.5.2.1.1.13
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvPlacement
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.14
|
|
type: gauge
|
|
help: SAS Physical Drive Placement - 1.3.6.1.4.1.232.5.5.2.1.1.14
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
- name: cpqSasPhyDrvHotPlug
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.15
|
|
type: gauge
|
|
help: SAS Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.5.2.1.1.15
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: hotPlug
|
|
3: nonHotPlug
|
|
- name: cpqSasPhyDrvType
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.16
|
|
type: gauge
|
|
help: SAS Physical Drive Type - 1.3.6.1.4.1.232.5.5.2.1.1.16
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: sas
|
|
3: sata
|
|
- name: cpqSasPhyDrvSasAddress
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.17
|
|
type: DisplayString
|
|
help: SAS Physical Drive SAS Address - 1.3.6.1.4.1.232.5.5.2.1.1.17
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvMediaType
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.18
|
|
type: gauge
|
|
help: SAS Physical Drive Media Type - 1.3.6.1.4.1.232.5.5.2.1.1.18
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rotatingPlatters
|
|
3: solidState
|
|
- name: cpqSasPhyDrvSSDWearStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.19
|
|
type: gauge
|
|
help: SAS Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.5.5.2.1.1.19
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: fiftySixDayThreshold
|
|
4: fivePercentThreshold
|
|
5: twoPercentThreshold
|
|
6: ssdWearOut
|
|
- name: cpqSasPhyDrvPowerOnHours
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.20
|
|
type: counter
|
|
help: SAS Physical Drive Power On Hours - 1.3.6.1.4.1.232.5.5.2.1.1.20
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSSDPercntEndrnceUsed
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.21
|
|
type: gauge
|
|
help: SAS Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.5.5.2.1.1.21
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSSDEstTimeRemainingHours
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.22
|
|
type: counter
|
|
help: SAS Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.5.5.2.1.1.22
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvAuthenticationStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.23
|
|
type: gauge
|
|
help: SAS Physical Drive Authentication Status - 1.3.6.1.4.1.232.5.5.2.1.1.23
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: authenticationFailed
|
|
4: authenticationPassed
|
|
- name: cpqSasPhyDrvSmartCarrierAppFWRev
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.24
|
|
type: gauge
|
|
help: SAS Physical Drive Smart Carrier Application Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.24
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSmartCarrierBootldrFWRev
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.25
|
|
type: gauge
|
|
help: SAS Physical Drive Smart Carrier Bootloader Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.25
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvCurrTemperature
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.26
|
|
type: gauge
|
|
help: SAS Physical Drive Current Operating Temperature degrees Celsius - 1.3.6.1.4.1.232.5.5.2.1.1.26
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvTemperatureThreshold
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.27
|
|
type: gauge
|
|
help: SAS Physical Drive Maximum Operating Temperature in degrees Celsius - 1.3.6.1.4.1.232.5.5.2.1.1.27
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSsBoxModel
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.28
|
|
type: DisplayString
|
|
help: SAS Physical Drive Box Model - 1.3.6.1.4.1.232.5.5.2.1.1.28
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSsBoxFwRev
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.29
|
|
type: DisplayString
|
|
help: SAS Physical Drive Box Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.29
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSsBoxVendor
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.30
|
|
type: DisplayString
|
|
help: SAS Physical Drive Box Vendor This is the SAS drive box`s vendor name -
|
|
1.3.6.1.4.1.232.5.5.2.1.1.30
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSsBoxSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.31
|
|
type: DisplayString
|
|
help: SAS Physical Drive Box Serial Number - 1.3.6.1.4.1.232.5.5.2.1.1.31
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvHbaIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.1
|
|
type: gauge
|
|
help: SAS Logical Drive HBA Index - 1.3.6.1.4.1.232.5.5.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.2
|
|
type: gauge
|
|
help: SAS Logical Drive Index - 1.3.6.1.4.1.232.5.5.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvRaidLevel
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.3
|
|
type: gauge
|
|
help: SAS Logical Drive RAID Level - 1.3.6.1.4.1.232.5.5.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: raid0
|
|
3: raid1
|
|
4: raid0plus1
|
|
5: raid5
|
|
6: raid15
|
|
7: volume
|
|
- name: cpqSasLogDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.4
|
|
type: gauge
|
|
help: SAS Logical Drive Status - 1.3.6.1.4.1.232.5.5.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: rebuilding
|
|
5: failed
|
|
6: offline
|
|
- name: cpqSasLogDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.5
|
|
type: gauge
|
|
help: SAS Logical Drive Condition - 1.3.6.1.4.1.232.5.5.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasLogDrvRebuildingDisk
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.6
|
|
type: gauge
|
|
help: SAS Logical Drive Rebuilding Disk - 1.3.6.1.4.1.232.5.5.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvCapacity
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.7
|
|
type: gauge
|
|
help: SAS Logical Drive Size - 1.3.6.1.4.1.232.5.5.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvStripeSize
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.8
|
|
type: gauge
|
|
help: SAS Logical Drive Stripe Size - 1.3.6.1.4.1.232.5.5.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvPhyDrvIds
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.9
|
|
type: OctetString
|
|
help: SAS Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.5.5.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvSpareIds
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.10
|
|
type: OctetString
|
|
help: SAS Logical Drive Spare Drive IDs - 1.3.6.1.4.1.232.5.5.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvOsName
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.11
|
|
type: DisplayString
|
|
help: SAS Logical Drive OS Name - 1.3.6.1.4.1.232.5.5.3.1.1.11
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvRebuildingPercent
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.12
|
|
type: gauge
|
|
help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.5.5.3.1.1.12
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvHbaIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.1
|
|
type: gauge
|
|
help: SAS Tape Drive HBA Index - 1.3.6.1.4.1.232.5.5.4.1.1.1
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.2
|
|
type: gauge
|
|
help: SAS Tape Drive Index - 1.3.6.1.4.1.232.5.5.4.1.1.2
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvLocationString
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.3
|
|
type: DisplayString
|
|
help: SAS Tape Drive Location String - 1.3.6.1.4.1.232.5.5.4.1.1.3
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvName
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.4
|
|
type: DisplayString
|
|
help: SAS Tape Drive Name - 1.3.6.1.4.1.232.5.5.4.1.1.4
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.5
|
|
type: gauge
|
|
help: SAS Physical Drive Status - 1.3.6.1.4.1.232.5.5.4.1.1.5
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: offline
|
|
- name: cpqSasTapeDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.6
|
|
type: gauge
|
|
help: SAS Tape Drive Condition - 1.3.6.1.4.1.232.5.5.4.1.1.6
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasTapeDrvFWRev
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.7
|
|
type: DisplayString
|
|
help: SAS Tape Drive Firmware Revision - 1.3.6.1.4.1.232.5.5.4.1.1.7
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.8
|
|
type: DisplayString
|
|
help: SAS Tape Drive Serial Number - 1.3.6.1.4.1.232.5.5.4.1.1.8
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvSasAddress
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.9
|
|
type: DisplayString
|
|
help: SAS Tape Drive SAS Address - 1.3.6.1.4.1.232.5.5.4.1.1.9
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqHeResMem2ModuleSize
|
|
oid: 1.3.6.1.4.1.232.6.2.14.13.1.6
|
|
type: gauge
|
|
help: Module memory size in kilobytes - 1.3.6.1.4.1.232.6.2.14.13.1.6
|
|
indexes:
|
|
- labelname: cpqHeResMem2Module
|
|
type: gauge
|
|
- name: cpqHePowerMeterSupport
|
|
oid: 1.3.6.1.4.1.232.6.2.15.1
|
|
type: gauge
|
|
help: This value specifies whether Power Meter is supported by this Server -
|
|
1.3.6.1.4.1.232.6.2.15.1
|
|
enum_values:
|
|
1: other
|
|
2: supported
|
|
3: unsupported
|
|
- name: cpqHePowerMeterStatus
|
|
oid: 1.3.6.1.4.1.232.6.2.15.2
|
|
type: gauge
|
|
help: This value specifies whether Power Meter reading is supported by this Server -
|
|
1.3.6.1.4.1.232.6.2.15.2
|
|
enum_values:
|
|
1: other
|
|
2: present
|
|
3: absent
|
|
- name: cpqHePowerMeterCurrReading
|
|
oid: 1.3.6.1.4.1.232.6.2.15.3
|
|
type: gauge
|
|
help: This is the current Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.3
|
|
- name: cpqHePowerMeterPrevReading
|
|
oid: 1.3.6.1.4.1.232.6.2.15.4
|
|
type: gauge
|
|
help: This is the previous Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.4
|
|
- name: cpqHeHWBiosCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.16.1
|
|
type: gauge
|
|
help: This value indicates an error has been detected during Pre-OS Test (POST)
|
|
or during initial hardware initialization - 1.3.6.1.4.1.232.6.2.16.1
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeSysBackupBatteryCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.17.1
|
|
type: gauge
|
|
help: This value specifies the overall condition of the battery backup sub-system.
|
|
- 1.3.6.1.4.1.232.6.2.17.1
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeSysBatteryChassis
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.1
|
|
type: gauge
|
|
help: The system chassis number. - 1.3.6.1.4.1.232.6.2.17.2.1.1
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryIndex
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.2
|
|
type: gauge
|
|
help: The battery index number within this chassis. - 1.3.6.1.4.1.232.6.2.17.2.1.2
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryPresent
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.3
|
|
type: gauge
|
|
help: Indicates whether the backup battery is present in the chassis. - 1.3.6.1.4.1.232.6.2.17.2.1.3
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: absent
|
|
3: present
|
|
- name: cpqHeSysBatteryCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.4
|
|
type: gauge
|
|
help: The condition of the backup battery - 1.3.6.1.4.1.232.6.2.17.2.1.4
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeSysBatteryStatus
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.5
|
|
type: gauge
|
|
help: The status of the battery. - 1.3.6.1.4.1.232.6.2.17.2.1.5
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: noError
|
|
2: generalFailure
|
|
3: shutdownHighResistance
|
|
4: shutdownLowVoltage
|
|
5: shutdownShortCircuit
|
|
6: shutdownChargeTimeout
|
|
7: shutdownOverTemperature
|
|
8: shutdownDischargeMinVoltage
|
|
9: shutdownDischargeCurrent
|
|
10: shutdownLoadCountHigh
|
|
11: shutdownEnablePin
|
|
12: shutdownOverCurrent
|
|
13: shutdownPermanentFailure
|
|
14: shutdownBackupTimeExceeded
|
|
15: predictiveFailure
|
|
- name: cpqHeSysBatteryCapacityMaximum
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.6
|
|
type: gauge
|
|
help: The maximum capacity of the battery in watts. - 1.3.6.1.4.1.232.6.2.17.2.1.6
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryProductName
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.7
|
|
type: DisplayString
|
|
help: The battery product name. - 1.3.6.1.4.1.232.6.2.17.2.1.7
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryModel
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.8
|
|
type: DisplayString
|
|
help: The battery model name. - 1.3.6.1.4.1.232.6.2.17.2.1.8
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatterySerialNumber
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.9
|
|
type: DisplayString
|
|
help: The battery serial number. - 1.3.6.1.4.1.232.6.2.17.2.1.9
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryFirmwareRev
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.10
|
|
type: DisplayString
|
|
help: The battery firmware revision - 1.3.6.1.4.1.232.6.2.17.2.1.10
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatterySparePartNum
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.11
|
|
type: DisplayString
|
|
help: The battery part number or spare part number. - 1.3.6.1.4.1.232.6.2.17.2.1.11
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureChassis
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.1
|
|
type: gauge
|
|
help: The System Chassis number. - 1.3.6.1.4.1.232.6.2.6.8.1.1
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureIndex
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.2
|
|
type: gauge
|
|
help: A number that uniquely specifies this temperature sensor description. -
|
|
1.3.6.1.4.1.232.6.2.6.8.1.2
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureLocale
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.3
|
|
type: EnumAsInfo
|
|
help: This specifies the location of the temperature sensor present in the system.
|
|
- 1.3.6.1.4.1.232.6.2.6.8.1.3
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: system
|
|
4: systemBoard
|
|
5: ioBoard
|
|
6: cpu
|
|
7: memory
|
|
8: storage
|
|
9: removableMedia
|
|
10: powerSupply
|
|
11: ambient
|
|
12: chassis
|
|
13: bridgeCard
|
|
- name: cpqHeTemperatureCelsius
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.4
|
|
type: gauge
|
|
help: This is the current temperature sensor reading in degrees celsius - 1.3.6.1.4.1.232.6.2.6.8.1.4
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureThreshold
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.5
|
|
type: gauge
|
|
help: This is the shutdown threshold temperature sensor setting in degrees celsius
|
|
- 1.3.6.1.4.1.232.6.2.6.8.1.5
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.6
|
|
type: gauge
|
|
help: The Temperature sensor condition - 1.3.6.1.4.1.232.6.2.6.8.1.6
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeTemperatureThresholdType
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.7
|
|
type: gauge
|
|
help: This specifies the type of this instance of temperature sensor - 1.3.6.1.4.1.232.6.2.6.8.1.7
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
5: blowout
|
|
9: caution
|
|
15: critical
|
|
16: noreaction
|
|
- name: cpqHeTemperatureHwLocation
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.8
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the temperature sensor - 1.3.6.1.4.1.232.6.2.6.8.1.8
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeFltTolPwrSupplyCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.9.1
|
|
type: gauge
|
|
help: This value specifies the overall condition of the fault tolerant power supply
|
|
sub-system. - 1.3.6.1.4.1.232.6.2.9.1
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeFltTolPwrSupplyStatus
|
|
oid: 1.3.6.1.4.1.232.6.2.9.2
|
|
type: gauge
|
|
help: This value specifies the status of the fault tolerant power supply. - 1.3.6.1.4.1.232.6.2.9.2
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notInstalled
|
|
4: installed
|
|
- name: cpqHeFltTolPowerSupplyChassis
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.1
|
|
type: gauge
|
|
help: The system chassis number. - 1.3.6.1.4.1.232.6.2.9.3.1.1
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyBay
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.2
|
|
type: gauge
|
|
help: The bay number to index within this chassis. - 1.3.6.1.4.1.232.6.2.9.3.1.2
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyPresent
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.3
|
|
type: gauge
|
|
help: Indicates whether the power supply is present in the chassis. - 1.3.6.1.4.1.232.6.2.9.3.1.3
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: absent
|
|
3: present
|
|
- name: cpqHeFltTolPowerSupplyCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.4
|
|
type: gauge
|
|
help: The condition of the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.4
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeFltTolPowerSupplyStatus
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.5
|
|
type: gauge
|
|
help: The status of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.5
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: noError
|
|
2: generalFailure
|
|
3: bistFailure
|
|
4: fanFailure
|
|
5: tempFailure
|
|
6: interlockOpen
|
|
7: epromFailed
|
|
8: vrefFailed
|
|
9: dacFailed
|
|
10: ramTestFailed
|
|
11: voltageChannelFailed
|
|
12: orringdiodeFailed
|
|
13: brownOut
|
|
14: giveupOnStartup
|
|
15: nvramInvalid
|
|
16: calibrationTableInvalid
|
|
17: noPowerInput
|
|
- name: cpqHeFltTolPowerSupplyMainVoltage
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.6
|
|
type: gauge
|
|
help: The input main voltage of the power supply in volts. - 1.3.6.1.4.1.232.6.2.9.3.1.6
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyCapacityUsed
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.7
|
|
type: gauge
|
|
help: The currently used capacity of the power supply in watts. - 1.3.6.1.4.1.232.6.2.9.3.1.7
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyCapacityMaximum
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.8
|
|
type: gauge
|
|
help: The maximum capacity of the power supply in watts. - 1.3.6.1.4.1.232.6.2.9.3.1.8
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyRedundant
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.9
|
|
type: gauge
|
|
help: The redundancy state of the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.9
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notRedundant
|
|
3: redundant
|
|
- name: cpqHeFltTolPowerSupplyModel
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.10
|
|
type: DisplayString
|
|
help: The power supply model name. - 1.3.6.1.4.1.232.6.2.9.3.1.10
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplySerialNumber
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.11
|
|
type: DisplayString
|
|
help: The power supply serial number. - 1.3.6.1.4.1.232.6.2.9.3.1.11
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyAutoRev
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.12
|
|
type: OctetString
|
|
help: The power supply auto revision number. - 1.3.6.1.4.1.232.6.2.9.3.1.12
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyHotPlug
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.13
|
|
type: gauge
|
|
help: This indicates if the power supply is capable of being removed and/or inserted
|
|
while the system is in an operational state - 1.3.6.1.4.1.232.6.2.9.3.1.13
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: nonHotPluggable
|
|
3: hotPluggable
|
|
- name: cpqHeFltTolPowerSupplyFirmwareRev
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.14
|
|
type: DisplayString
|
|
help: The power supply firmware revision - 1.3.6.1.4.1.232.6.2.9.3.1.14
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyHwLocation
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.15
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.15
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplySparePartNum
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.16
|
|
type: DisplayString
|
|
help: The power supply part number or spare part number. - 1.3.6.1.4.1.232.6.2.9.3.1.16
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyRedundantPartner
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.17
|
|
type: gauge
|
|
help: This specifies the index of the redundant partner - 1.3.6.1.4.1.232.6.2.9.3.1.17
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyErrorCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.18
|
|
type: gauge
|
|
help: The Error condition of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.18
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: noError
|
|
2: generalFailure
|
|
3: overvoltage
|
|
4: overcurrent
|
|
5: overtemperature
|
|
6: powerinputloss
|
|
7: fanfailure
|
|
8: vinhighwarning
|
|
9: vinlowwarning
|
|
10: vouthighwarning
|
|
11: voutlowwarning
|
|
12: inlettemphighwarning
|
|
13: iinternaltemphighwarning
|
|
14: vauxhighwarning
|
|
15: vauxlowwarning
|
|
16: powersupplymismatch
|
|
17: goodinstandby
|
|
- name: cpqSm2CntlrRomDate
|
|
oid: 1.3.6.1.4.1.232.9.2.2.1
|
|
type: DisplayString
|
|
help: Remote Insight/ Integrated Lights-Out ROM Date - 1.3.6.1.4.1.232.9.2.2.1
|
|
- name: cpqSm2CntlrRomRevision
|
|
oid: 1.3.6.1.4.1.232.9.2.2.2
|
|
type: DisplayString
|
|
help: Remote Insight/ Integrated Lights-Out ROM Revision - 1.3.6.1.4.1.232.9.2.2.2
|
|
- name: cpqSm2CntlrVideoStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.3
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Video Hardware Status - 1.3.6.1.4.1.232.9.2.2.3
|
|
enum_values:
|
|
1: other
|
|
2: enabled
|
|
3: disabled
|
|
- name: cpqSm2CntlrBatteryEnabled
|
|
oid: 1.3.6.1.4.1.232.9.2.2.4
|
|
type: gauge
|
|
help: Remote Insight Battery Enabled - 1.3.6.1.4.1.232.9.2.2.4
|
|
enum_values:
|
|
1: other
|
|
2: enabled
|
|
3: disabled
|
|
4: noBattery
|
|
- name: cpqSm2CntlrBatteryStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.5
|
|
type: gauge
|
|
help: Remote Insight Battery Status - 1.3.6.1.4.1.232.9.2.2.5
|
|
enum_values:
|
|
1: other
|
|
2: batteryOk
|
|
3: batteryFailed
|
|
4: batteryDisconnected
|
|
- name: cpqSm2CntlrBatteryPercentCharged
|
|
oid: 1.3.6.1.4.1.232.9.2.2.6
|
|
type: gauge
|
|
help: Remote Insight Battery Percent Charged - 1.3.6.1.4.1.232.9.2.2.6
|
|
- name: cpqSm2CntlrAlertStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.7
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Alerting Status - 1.3.6.1.4.1.232.9.2.2.7
|
|
enum_values:
|
|
1: other
|
|
2: enabled
|
|
3: disabled
|
|
- name: cpqSm2CntlrPendingAlerts
|
|
oid: 1.3.6.1.4.1.232.9.2.2.8
|
|
type: gauge
|
|
help: Pending Remote Insight/ Integrated Lights-Out alerts - 1.3.6.1.4.1.232.9.2.2.8
|
|
enum_values:
|
|
1: other
|
|
2: noAlertsPending
|
|
3: alertsPending
|
|
4: clearPendingAlerts
|
|
- name: cpqSm2CntlrSelfTestErrors
|
|
oid: 1.3.6.1.4.1.232.9.2.2.9
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Self Test Errors - 1.3.6.1.4.1.232.9.2.2.9
|
|
- name: cpqSm2CntlrAgentLocation
|
|
oid: 1.3.6.1.4.1.232.9.2.2.10
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Agent Location - 1.3.6.1.4.1.232.9.2.2.10
|
|
enum_values:
|
|
1: hostOsAgent
|
|
2: firmwareAgent
|
|
3: remoteInsightPciFirmwareAgent
|
|
4: enclosureFirmwareAgent
|
|
- name: cpqSm2CntlrLastDataUpdate
|
|
oid: 1.3.6.1.4.1.232.9.2.2.11
|
|
type: OctetString
|
|
help: The date and time that the Remote Insight/ Integrated Lights-Out offline
|
|
data was last updated - 1.3.6.1.4.1.232.9.2.2.11
|
|
- name: cpqSm2CntlrDataStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.12
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Host OS Data Status - 1.3.6.1.4.1.232.9.2.2.12
|
|
enum_values:
|
|
1: other
|
|
2: noData
|
|
3: onlineData
|
|
4: offlineData
|
|
- name: cpqSm2CntlrColdReboot
|
|
oid: 1.3.6.1.4.1.232.9.2.2.13
|
|
type: gauge
|
|
help: 'Remote Insight/ Integrated Lights-Out Server Cold Reboot The following
|
|
values are defined: notAvailable(1) Cold reboot of the system is not available
|
|
- 1.3.6.1.4.1.232.9.2.2.13'
|
|
enum_values:
|
|
1: notAvailable
|
|
2: available
|
|
3: doColdReboot
|
|
- name: cpqSm2CntlrBadLoginAttemptsThresh
|
|
oid: 1.3.6.1.4.1.232.9.2.2.14
|
|
type: gauge
|
|
help: Maximum Unauthorized Login Attempts Threshold - 1.3.6.1.4.1.232.9.2.2.14
|
|
- name: cpqSm2CntlrBoardSerialNumber
|
|
oid: 1.3.6.1.4.1.232.9.2.2.15
|
|
type: DisplayString
|
|
help: Remote Insight/ Integrated Lights-Out Serial Number - 1.3.6.1.4.1.232.9.2.2.15
|
|
- name: cpqSm2CntlrRemoteSessionStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.16
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Session Status - 1.3.6.1.4.1.232.9.2.2.16
|
|
enum_values:
|
|
1: other
|
|
2: active
|
|
3: inactive
|
|
- name: cpqSm2CntlrInterfaceStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.17
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Interface Status - 1.3.6.1.4.1.232.9.2.2.17
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: notResponding
|
|
- name: cpqSm2CntlrSystemId
|
|
oid: 1.3.6.1.4.1.232.9.2.2.18
|
|
type: DisplayString
|
|
help: Remote Insight/ Integrated Lights-Out System ID - 1.3.6.1.4.1.232.9.2.2.18
|
|
- name: cpqSm2CntlrKeyboardCableStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.19
|
|
type: gauge
|
|
help: Remote Insight Keyboard Cable Status - 1.3.6.1.4.1.232.9.2.2.19
|
|
enum_values:
|
|
1: other
|
|
2: connected
|
|
3: disconnected
|
|
- name: cpqSm2ServerIpAddress
|
|
oid: 1.3.6.1.4.1.232.9.2.2.20
|
|
type: InetAddressIPv4
|
|
help: The IP address for this servers connection to the Remote Insight/ Integrated
|
|
Lights-Out - 1.3.6.1.4.1.232.9.2.2.20
|
|
- name: cpqSm2CntlrModel
|
|
oid: 1.3.6.1.4.1.232.9.2.2.21
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Model - 1.3.6.1.4.1.232.9.2.2.21
|
|
enum_values:
|
|
1: other
|
|
2: eisaRemoteInsightBoard
|
|
3: pciRemoteInsightBoard
|
|
4: pciLightsOutRemoteInsightBoard
|
|
5: pciIntegratedLightsOutRemoteInsight
|
|
6: pciLightsOutRemoteInsightBoardII
|
|
7: pciIntegratedLightsOutRemoteInsight2
|
|
8: pciLightsOut100series
|
|
9: pciIntegratedLightsOutRemoteInsight3
|
|
10: pciIntegratedLightsOutRemoteInsight4
|
|
11: pciIntegratedLightsOutRemoteInsight5
|
|
- name: cpqSm2CntlrSelfTestErrorMask
|
|
oid: 1.3.6.1.4.1.232.9.2.2.22
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Self Test Error Mask - 1.3.6.1.4.1.232.9.2.2.22
|
|
- name: cpqSm2CntlrMouseCableStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.23
|
|
type: gauge
|
|
help: Remote Insight Mouse Cable Status - 1.3.6.1.4.1.232.9.2.2.23
|
|
enum_values:
|
|
1: other
|
|
2: connected
|
|
3: disconnected
|
|
- name: cpqSm2CntlrVirtualPowerCableStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.24
|
|
type: gauge
|
|
help: Remote Insight Virtual Power Cable Status - 1.3.6.1.4.1.232.9.2.2.24
|
|
enum_values:
|
|
1: other
|
|
2: connected
|
|
3: disconnected
|
|
4: notApplicable
|
|
- name: cpqSm2CntlrExternalPowerCableStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.25
|
|
type: gauge
|
|
help: Remote Insight External Power Cable Status - 1.3.6.1.4.1.232.9.2.2.25
|
|
enum_values:
|
|
1: other
|
|
2: externallyConnected
|
|
3: disconnected
|
|
4: internallyConnected
|
|
5: externallyAndInternallyConnected
|
|
6: notApplicable
|
|
- name: cpqSm2CntlrHostGUID
|
|
oid: 1.3.6.1.4.1.232.9.2.2.26
|
|
type: OctetString
|
|
help: The globally unique identifier of this server - 1.3.6.1.4.1.232.9.2.2.26
|
|
- name: cpqSm2CntlriLOSecurityOverrideSwitchState
|
|
oid: 1.3.6.1.4.1.232.9.2.2.27
|
|
type: gauge
|
|
help: Integrated Lights-Out Security Override Switch State - 1.3.6.1.4.1.232.9.2.2.27
|
|
enum_values:
|
|
1: notSupported
|
|
2: set
|
|
3: notSet
|
|
- name: cpqSm2CntlrHardwareVer
|
|
oid: 1.3.6.1.4.1.232.9.2.2.28
|
|
type: gauge
|
|
help: Hardware Version of Remote Insight/ Integrated Lights-Out. - 1.3.6.1.4.1.232.9.2.2.28
|
|
- name: cpqSm2CntlrAction
|
|
oid: 1.3.6.1.4.1.232.9.2.2.29
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Action Flags - 1.3.6.1.4.1.232.9.2.2.29
|
|
- name: cpqSm2CntlrLicenseActive
|
|
oid: 1.3.6.1.4.1.232.9.2.2.30
|
|
type: gauge
|
|
help: Remote Insight License State - 1.3.6.1.4.1.232.9.2.2.30
|
|
enum_values:
|
|
1: none
|
|
2: iloAdvanced
|
|
3: iloLight
|
|
4: iloAdvancedBlade
|
|
5: iloStandard
|
|
6: iloEssentials
|
|
7: iloScaleOut
|
|
8: iloAdvancedPremiumSecurity
|
|
- name: cpqSm2CntlrLicenseKey
|
|
oid: 1.3.6.1.4.1.232.9.2.2.31
|
|
type: DisplayString
|
|
help: iLO Active ASCII License key string - 1.3.6.1.4.1.232.9.2.2.31
|
|
- name: cpqSm2CntlrServerPowerState
|
|
oid: 1.3.6.1.4.1.232.9.2.2.32
|
|
type: gauge
|
|
help: The current power state for the server - 1.3.6.1.4.1.232.9.2.2.32
|
|
enum_values:
|
|
1: unknown
|
|
2: poweredOff
|
|
3: poweredOn
|
|
4: insufficientPowerOrPowerOnDenied
|
|
- name: cpqSm2CntlrSysAutoShutdownCause
|
|
oid: 1.3.6.1.4.1.232.9.2.2.33
|
|
type: gauge
|
|
help: Indicate the reason for triggering system auto shutdown or cancelling auto
|
|
shutdown. - 1.3.6.1.4.1.232.9.2.2.33
|
|
enum_values:
|
|
1: fanFailure
|
|
2: overheatCondition
|
|
3: vrmFailure
|
|
4: powerSupplyFailure
|
|
5: systemRunningOnBatteryBackupUnit
|
|
129: aborted
|
|
130: fanFailureAborted
|
|
131: overheatAborted
|
|
132: vrmFailureAborted
|
|
133: softPowerDown
|
|
134: softwareAutomaticServerRecovery
|
|
135: powerSupplyFailureAborted
|
|
- name: cpqSm2CntlrSecurityState
|
|
oid: 1.3.6.1.4.1.232.9.2.2.34
|
|
type: gauge
|
|
help: Indicate security state - 1.3.6.1.4.1.232.9.2.2.34
|
|
enum_values:
|
|
1: factory
|
|
2: wipe
|
|
3: production
|
|
4: highSecurity
|
|
5: fips
|
|
6: cnsa
|
|
- name: cpqSm2WDTimerType
|
|
oid: 1.3.6.1.4.1.232.9.2.2.35
|
|
type: gauge
|
|
help: Indicate the watchdog timer type. - 1.3.6.1.4.1.232.9.2.2.35
|
|
enum_values:
|
|
1: unknown
|
|
2: ipmi
|
|
- name: cpqSm2WDTimerTimeoutDetails
|
|
oid: 1.3.6.1.4.1.232.9.2.2.36
|
|
type: DisplayString
|
|
help: Indicate the watchdog timer timeout action and timer details. - 1.3.6.1.4.1.232.9.2.2.36
|
|
- name: cpqSm2CntlrOverallSecStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.37
|
|
type: gauge
|
|
help: The field indicates the overall security status. - 1.3.6.1.4.1.232.9.2.2.37
|
|
enum_values:
|
|
1: Ok
|
|
2: Risk
|
|
3: Ignored
|
|
version: 2
|
|
auth:
|
|
community: public
|
|
hpe_sim:
|
|
walk:
|
|
- 1.3.6.1.4.1.232.1.2.2.1.1
|
|
- 1.3.6.1.4.1.232.11
|
|
- 1.3.6.1.4.1.232.14
|
|
- 1.3.6.1.4.1.232.3.2.2.1
|
|
- 1.3.6.1.4.1.232.3.2.3.1.1
|
|
- 1.3.6.1.4.1.232.3.2.5.1.1
|
|
- 1.3.6.1.4.1.232.5
|
|
- 1.3.6.1.4.1.232.6.2.14.13.1.6
|
|
- 1.3.6.1.4.1.232.6.2.15
|
|
- 1.3.6.1.4.1.232.6.2.16
|
|
- 1.3.6.1.4.1.232.6.2.17
|
|
- 1.3.6.1.4.1.232.6.2.6.8.1
|
|
- 1.3.6.1.4.1.232.6.2.9
|
|
- 1.3.6.1.4.1.232.9.2.2
|
|
get:
|
|
- 1.3.6.1.2.1.1.3.0
|
|
metrics:
|
|
- name: sysUpTime
|
|
oid: 1.3.6.1.2.1.1.3
|
|
type: gauge
|
|
help: The time (in hundredths of a second) since the network management portion
|
|
of the system was last re-initialized. - 1.3.6.1.2.1.1.3
|
|
- name: cpqSeCpuUnitIndex
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.1
|
|
type: gauge
|
|
help: This is a number that uniquely specifies a processor unit - 1.3.6.1.4.1.232.1.2.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuSlot
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.2
|
|
type: gauge
|
|
help: This value represents this processor`s slot - 1.3.6.1.4.1.232.1.2.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuName
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.3
|
|
type: DisplayString
|
|
help: The name of this processor - 1.3.6.1.4.1.232.1.2.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuSpeed
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.4
|
|
type: gauge
|
|
help: The current internal speed of this processor in megahertz - 1.3.6.1.4.1.232.1.2.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuStep
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.5
|
|
type: gauge
|
|
help: This step of the processor - 1.3.6.1.4.1.232.1.2.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuStatus
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.6
|
|
type: gauge
|
|
help: The status of the processor - 1.3.6.1.4.1.232.1.2.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
5: disabled
|
|
- name: cpqSeCpuExtSpeed
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.7
|
|
type: gauge
|
|
help: This is the external frequency in megahertz of the processor bus - 1.3.6.1.4.1.232.1.2.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuDesigner
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.8
|
|
type: gauge
|
|
help: This attribute specifies the manufacturer which designs this CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: intel
|
|
3: amd
|
|
4: cyrix
|
|
5: ti
|
|
6: nexgen
|
|
7: compaq
|
|
8: samsung
|
|
9: mitsubishi
|
|
10: mips
|
|
- name: cpqSeCpuSocketNumber
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.9
|
|
type: gauge
|
|
help: The physical socket number of the CPU chip - 1.3.6.1.4.1.232.1.2.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuThreshPassed
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.10
|
|
type: gauge
|
|
help: CPU threshold passed (Exceeded) - 1.3.6.1.4.1.232.1.2.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unsupported
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqSeCpuHwLocation
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.11
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the CPU - 1.3.6.1.4.1.232.1.2.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuCellTablePtr
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.12
|
|
type: gauge
|
|
help: This is the index for the cell in cpqSeCellTable where this CPU is physically
|
|
located. - 1.3.6.1.4.1.232.1.2.2.1.1.12
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuPowerpodStatus
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.13
|
|
type: gauge
|
|
help: This is the status of CPU power pod - 1.3.6.1.4.1.232.1.2.2.1.1.13
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: notfailed
|
|
2: failed
|
|
- name: cpqSeCpuArchitectureRevision
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.14
|
|
type: DisplayString
|
|
help: This is the CPU architecture revision. - 1.3.6.1.4.1.232.1.2.2.1.1.14
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuCore
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.15
|
|
type: gauge
|
|
help: The number of cores in this CPU module - 1.3.6.1.4.1.232.1.2.2.1.1.15
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUSerialNumber
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.16
|
|
type: DisplayString
|
|
help: The OEM serial number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.16
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUPartNumber
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.17
|
|
type: DisplayString
|
|
help: The OEM part number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.17
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUSerialNumberMfgr
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.18
|
|
type: DisplayString
|
|
help: The manufacturer serial number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.18
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUPartNumberMfgr
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.19
|
|
type: DisplayString
|
|
help: The manufacturer part number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.19
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUCoreIndex
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.20
|
|
type: gauge
|
|
help: This is a number that uniquely identifies a core in a CPU unit. - 1.3.6.1.4.1.232.1.2.2.1.1.20
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUMaxSpeed
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.21
|
|
type: gauge
|
|
help: This is the maximum internal speed in megahertz this processor can support
|
|
- 1.3.6.1.4.1.232.1.2.2.1.1.21
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUCoreThreadIndex
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.22
|
|
type: gauge
|
|
help: This is an unique number to identify the running threads in a CPU core.
|
|
- 1.3.6.1.4.1.232.1.2.2.1.1.22
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUChipGenerationName
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.23
|
|
type: DisplayString
|
|
help: CPU chip generation name e.g - 1.3.6.1.4.1.232.1.2.2.1.1.23
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUMultiThreadStatus
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.24
|
|
type: gauge
|
|
help: This OID identifies whether the CPU threading is enabled or not. - 1.3.6.1.4.1.232.1.2.2.1.1.24
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: enabled
|
|
3: disabled
|
|
- name: cpqSeCPUCoreMaxThreads
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.25
|
|
type: gauge
|
|
help: This OID indicates the maximum number of threads that a cpu core is capable
|
|
of. - 1.3.6.1.4.1.232.1.2.2.1.1.25
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuLowPowerStatus
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.26
|
|
type: gauge
|
|
help: Servers like Itanium has capability to lower power supply to CPU if it is
|
|
idle for specified period of time - 1.3.6.1.4.1.232.1.2.2.1.1.26
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: lowpowered
|
|
3: normalpowered
|
|
4: highpowered
|
|
- name: cpqSeCpuPrimary
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.27
|
|
type: gauge
|
|
help: On SMP systems one of the CPU is set to Primary and the other CPUs as secondary
|
|
- 1.3.6.1.4.1.232.1.2.2.1.1.27
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqSeCpuCoreSteppingText
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.28
|
|
type: DisplayString
|
|
help: The processor stepping version string - 1.3.6.1.4.1.232.1.2.2.1.1.28
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuCurrentPerformanceState
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.29
|
|
type: gauge
|
|
help: This OID returns the current performance state of this processor - 1.3.6.1.4.1.232.1.2.2.1.1.29
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuMinPerformanceState
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.30
|
|
type: gauge
|
|
help: This OID returns the minimum performance state set for this processor -
|
|
1.3.6.1.4.1.232.1.2.2.1.1.30
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuMaxPerformanceState
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.31
|
|
type: gauge
|
|
help: This OID returns the maximum performance state set for this processor -
|
|
1.3.6.1.4.1.232.1.2.2.1.1.31
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqHoMibRevMajor
|
|
oid: 1.3.6.1.4.1.232.11.1.1
|
|
type: gauge
|
|
help: The Major Revision level of the MIB - 1.3.6.1.4.1.232.11.1.1
|
|
- name: cpqHoMibRevMinor
|
|
oid: 1.3.6.1.4.1.232.11.1.2
|
|
type: gauge
|
|
help: The Minor Revision level of the MIB - 1.3.6.1.4.1.232.11.1.2
|
|
- name: cpqHoMibCondition
|
|
oid: 1.3.6.1.4.1.232.11.1.3
|
|
type: gauge
|
|
help: The overall condition - 1.3.6.1.4.1.232.11.1.3
|
|
enum_values:
|
|
1: unknown
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoOsCommonPollFreq
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.1
|
|
type: gauge
|
|
help: The Insight Agent`s polling frequency - 1.3.6.1.4.1.232.11.2.1.4.1
|
|
- name: cpqHoOsCommonModuleIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.1
|
|
type: gauge
|
|
help: A unique index for this module description. - 1.3.6.1.4.1.232.11.2.1.4.2.1.1
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoOsCommonModuleName
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.2
|
|
type: DisplayString
|
|
help: The module name. - 1.3.6.1.4.1.232.11.2.1.4.2.1.2
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoOsCommonModuleVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.3
|
|
type: DisplayString
|
|
help: The module version in XX.YY format - 1.3.6.1.4.1.232.11.2.1.4.2.1.3
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoOsCommonModuleDate
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.4
|
|
type: OctetString
|
|
help: The module date - 1.3.6.1.4.1.232.11.2.1.4.2.1.4
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoOsCommonModulePurpose
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.5
|
|
type: DisplayString
|
|
help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.11.2.1.4.2.1.5
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoName
|
|
oid: 1.3.6.1.4.1.232.11.2.2.1
|
|
type: DisplayString
|
|
help: The name of the host operating system (OS). - 1.3.6.1.4.1.232.11.2.2.1
|
|
- name: cpqHoVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.2.2
|
|
type: DisplayString
|
|
help: The version of the host OS. - 1.3.6.1.4.1.232.11.2.2.2
|
|
- name: cpqHoDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.2.3
|
|
type: DisplayString
|
|
help: A further description of the host OS. - 1.3.6.1.4.1.232.11.2.2.3
|
|
- name: cpqHoOsType
|
|
oid: 1.3.6.1.4.1.232.11.2.2.4
|
|
type: gauge
|
|
help: Host Operating system enumeration. - 1.3.6.1.4.1.232.11.2.2.4
|
|
enum_values:
|
|
1: other
|
|
2: netware
|
|
3: windowsnt
|
|
4: sco-unix
|
|
5: unixware
|
|
6: os-2
|
|
7: ms-dos
|
|
8: dos-windows
|
|
9: windows95
|
|
10: windows98
|
|
11: open-vms
|
|
12: nsk
|
|
13: windowsCE
|
|
14: linux
|
|
15: windows2000
|
|
16: tru64UNIX
|
|
17: windows2003
|
|
18: windows2003-x64
|
|
19: solaris
|
|
20: windows2003-ia64
|
|
21: windows2008
|
|
22: windows2008-x64
|
|
23: windows2008-ia64
|
|
24: vmware-esx
|
|
25: vmware-esxi
|
|
26: windows2012
|
|
27: windows7
|
|
28: windows7-x64
|
|
29: windows8
|
|
30: windows8-x64
|
|
31: windows81
|
|
32: windows81-x64
|
|
33: windowsxp
|
|
34: windowsxp-x64
|
|
35: windowsvista
|
|
36: windowsvista-x64
|
|
37: windows2008-r2
|
|
38: windows2012-r2
|
|
39: rhel
|
|
40: rhel-64
|
|
41: solaris-64
|
|
42: sles
|
|
43: sles-64
|
|
44: ubuntu
|
|
45: ubuntu-64
|
|
46: debian
|
|
47: debian-64
|
|
48: linux-64-bit
|
|
49: other-64-bit
|
|
50: centos-32bit
|
|
51: centos-64bit
|
|
52: oracle-linux32
|
|
53: oracle-linux64
|
|
54: apple-osx
|
|
55: windows2016
|
|
56: nanoserver
|
|
57: windows2019
|
|
- name: cpqHoTelnet
|
|
oid: 1.3.6.1.4.1.232.11.2.2.5
|
|
type: gauge
|
|
help: Telnet on socket 23 is available. - 1.3.6.1.4.1.232.11.2.2.5
|
|
enum_values:
|
|
1: other
|
|
2: available
|
|
3: notavailable
|
|
- name: cpqHoSystemRole
|
|
oid: 1.3.6.1.4.1.232.11.2.2.6
|
|
type: DisplayString
|
|
help: The system role - 1.3.6.1.4.1.232.11.2.2.6
|
|
- name: cpqHoSystemRoleDetail
|
|
oid: 1.3.6.1.4.1.232.11.2.2.7
|
|
type: DisplayString
|
|
help: The system detailed description - 1.3.6.1.4.1.232.11.2.2.7
|
|
- name: cpqHoCrashDumpState
|
|
oid: 1.3.6.1.4.1.232.11.2.2.8
|
|
type: gauge
|
|
help: Crash dump state - 1.3.6.1.4.1.232.11.2.2.8
|
|
enum_values:
|
|
1: completememorydump
|
|
2: kernelmemorydump
|
|
3: smallmemorydump
|
|
4: none
|
|
- name: cpqHoCrashDumpCondition
|
|
oid: 1.3.6.1.4.1.232.11.2.2.9
|
|
type: gauge
|
|
help: The condition of the Crash dump configuration. - 1.3.6.1.4.1.232.11.2.2.9
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoCrashDumpMonitoring
|
|
oid: 1.3.6.1.4.1.232.11.2.2.10
|
|
type: gauge
|
|
help: Enable/disable crash dump monitoring - 1.3.6.1.4.1.232.11.2.2.10
|
|
enum_values:
|
|
1: enabled
|
|
2: disabled
|
|
- name: cpqHoMaxLogicalCPUSupported
|
|
oid: 1.3.6.1.4.1.232.11.2.2.11
|
|
type: gauge
|
|
help: Maximum number of logical CPUs supported by Operating System. - 1.3.6.1.4.1.232.11.2.2.11
|
|
- name: cpqHoSystemName
|
|
oid: 1.3.6.1.4.1.232.11.2.2.12
|
|
type: DisplayString
|
|
help: Full computer name of the host - 1.3.6.1.4.1.232.11.2.2.12
|
|
- name: cpqHosysDescr
|
|
oid: 1.3.6.1.4.1.232.11.2.2.13
|
|
type: DisplayString
|
|
help: The value that would be returned in the RFC-1213 sysDescr MIB element -
|
|
1.3.6.1.4.1.232.11.2.2.13
|
|
- name: cpqHoCpuUtilUnitIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.1
|
|
type: gauge
|
|
help: This number uniquely specifies a processor unit - 1.3.6.1.4.1.232.11.2.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilMin
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.2
|
|
type: gauge
|
|
help: The CPU utilization as a percentage of the theoretical maximum during the
|
|
last minute - 1.3.6.1.4.1.232.11.2.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilFiveMin
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.3
|
|
type: gauge
|
|
help: The CPU utilization as a percentage of the theoretical maximum during the
|
|
last five minutes - 1.3.6.1.4.1.232.11.2.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilThirtyMin
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.4
|
|
type: gauge
|
|
help: The CPU utilization as a percentage of the theoretical maximum during the
|
|
last thirty minutes - 1.3.6.1.4.1.232.11.2.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilHour
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.5
|
|
type: gauge
|
|
help: The CPU utilization as a percentage of the theoretical maximum during the
|
|
last hour - 1.3.6.1.4.1.232.11.2.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilHwLocation
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.6
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the CPU - 1.3.6.1.4.1.232.11.2.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.4.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.2
|
|
type: DisplayString
|
|
help: A description of the file system include the GUID. - 1.3.6.1.4.1.232.11.2.4.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysSpaceTotal
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.3
|
|
type: gauge
|
|
help: The file system size in megabytes - 1.3.6.1.4.1.232.11.2.4.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysSpaceUsed
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.4
|
|
type: gauge
|
|
help: The megabytes of file system space currently in use - 1.3.6.1.4.1.232.11.2.4.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysPercentSpaceUsed
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.5
|
|
type: gauge
|
|
help: The percent of file system space currently in use - 1.3.6.1.4.1.232.11.2.4.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysAllocUnitsTotal
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.6
|
|
type: gauge
|
|
help: The total number of files (directory entries) that can be stored on the
|
|
file system if a limit exists other than total space used - 1.3.6.1.4.1.232.11.2.4.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysAllocUnitsUsed
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.7
|
|
type: gauge
|
|
help: The number of files (directory entries) on this file system - 1.3.6.1.4.1.232.11.2.4.1.1.7
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysStatus
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.8
|
|
type: gauge
|
|
help: The Threshold Status - 1.3.6.1.4.1.232.11.2.4.1.1.8
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoFileSysShortDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.9
|
|
type: DisplayString
|
|
help: A description of the file system. - 1.3.6.1.4.1.232.11.2.4.1.1.9
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysCondition
|
|
oid: 1.3.6.1.4.1.232.11.2.4.2
|
|
type: gauge
|
|
help: The overall condition of File System Threshold - 1.3.6.1.4.1.232.11.2.4.2
|
|
enum_values:
|
|
1: unknown
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoIfPhysMapIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies this entry - 1.3.6.1.4.1.232.11.2.5.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapSlot
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.2
|
|
type: gauge
|
|
help: The number of the slot containing the physical hardware that implements
|
|
this interface - 1.3.6.1.4.1.232.11.2.5.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapIoBaseAddr
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.3
|
|
type: gauge
|
|
help: The base I/O address of the physical hardware that implements this interface.
|
|
- 1.3.6.1.4.1.232.11.2.5.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapIrq
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.4
|
|
type: gauge
|
|
help: The number of the IRQ (interrupt) used for this physical hardware interface
|
|
- 1.3.6.1.4.1.232.11.2.5.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapDma
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.5
|
|
type: gauge
|
|
help: The number of the DMA channel used for this physical hardware interface
|
|
- 1.3.6.1.4.1.232.11.2.5.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapMemBaseAddr
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.6
|
|
type: gauge
|
|
help: The base memory address used by this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapPort
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.7
|
|
type: gauge
|
|
help: The port number of the interface for multi-port NICs - 1.3.6.1.4.1.232.11.2.5.1.1.7
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapDuplexState
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.8
|
|
type: gauge
|
|
help: This variable describes the configured duplex state of the NIC. - 1.3.6.1.4.1.232.11.2.5.1.1.8
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: half
|
|
3: full
|
|
- name: cpqHoIfPhysMapCondition
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.9
|
|
type: gauge
|
|
help: The condition of this interface. - 1.3.6.1.4.1.232.11.2.5.1.1.9
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoIfPhysMapOverallCondition
|
|
oid: 1.3.6.1.4.1.232.11.2.5.2
|
|
type: gauge
|
|
help: The overall condition of all interfaces. - 1.3.6.1.4.1.232.11.2.5.2
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoSWRunningIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.6.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningName
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.2
|
|
type: DisplayString
|
|
help: The name of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.3
|
|
type: DisplayString
|
|
help: A description of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.4
|
|
type: DisplayString
|
|
help: The version of the software - 1.3.6.1.4.1.232.11.2.6.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningDate
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.5
|
|
type: OctetString
|
|
help: The software date - 1.3.6.1.4.1.232.11.2.6.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningMonitor
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.6
|
|
type: gauge
|
|
help: The user specified monitor option for a process. - 1.3.6.1.4.1.232.11.2.6.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: start
|
|
3: stop
|
|
4: startAndStop
|
|
5: count
|
|
6: startAndCount
|
|
7: countAndStop
|
|
8: startCountAndStop
|
|
- name: cpqHoSWRunningState
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.7
|
|
type: gauge
|
|
help: The current state of monitored process. - 1.3.6.1.4.1.232.11.2.6.1.1.7
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: started
|
|
3: stopped
|
|
- name: cpqHoSWRunningCount
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.8
|
|
type: gauge
|
|
help: For each process name, the number of instances of the process running on
|
|
the system is kept count of, in this variable. - 1.3.6.1.4.1.232.11.2.6.1.1.8
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningCountMin
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.9
|
|
type: gauge
|
|
help: This is the lower threshold on cpqHoSWRunningCount to be set by the user.
|
|
- 1.3.6.1.4.1.232.11.2.6.1.1.9
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningCountMax
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.10
|
|
type: gauge
|
|
help: This is the upper threshold on cpqHoSWRunningCount to be set by the user.
|
|
- 1.3.6.1.4.1.232.11.2.6.1.1.10
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningEventTime
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.11
|
|
type: OctetString
|
|
help: The system time at which the monitored event, as per cpqHoSWRunningMonitor,
|
|
last occurred - 1.3.6.1.4.1.232.11.2.6.1.1.11
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningStatus
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.12
|
|
type: gauge
|
|
help: The overall alarm state of the resources managed by the software, or the
|
|
software itself. - 1.3.6.1.4.1.232.11.2.6.1.1.12
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: normal
|
|
3: warning
|
|
4: minor
|
|
5: major
|
|
6: critical
|
|
7: disabled
|
|
- name: cpqHoSWRunningConfigStatus
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.13
|
|
type: gauge
|
|
help: The configuration state of the software - 1.3.6.1.4.1.232.11.2.6.1.1.13
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: starting
|
|
3: initialized
|
|
4: configured
|
|
5: operational
|
|
- name: cpqHoSWRunningIdentifier
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.14
|
|
type: DisplayString
|
|
help: The unique identifier of the sofware - 1.3.6.1.4.1.232.11.2.6.1.1.14
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningRedundancyMode
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.15
|
|
type: gauge
|
|
help: When the software is running in a high availability mode, the failover mode
|
|
of this instance of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.15
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: master
|
|
3: backup
|
|
4: slave
|
|
- name: cpqHoSwRunningTrapDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.6.2
|
|
type: DisplayString
|
|
help: The error message for a process monitor event. - 1.3.6.1.4.1.232.11.2.6.2
|
|
- name: cpqHoSwVerNextIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.7.1
|
|
type: gauge
|
|
help: The index of the next available entry in the cpqHoSwVer table - 1.3.6.1.4.1.232.11.2.7.1
|
|
- name: cpqHoSwVerIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies an entry in the cpqHoSwVer table. - 1.3.6.1.4.1.232.11.2.7.2.1.1
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerStatus
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.2
|
|
type: gauge
|
|
help: Status for the software item. - 1.3.6.1.4.1.232.11.2.7.2.1.2
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: loaded
|
|
3: notloaded
|
|
- name: cpqHoSwVerType
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.3
|
|
type: gauge
|
|
help: Type of software item. - 1.3.6.1.4.1.232.11.2.7.2.1.3
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: driver
|
|
3: agent
|
|
4: sysutil
|
|
5: application
|
|
6: keyfile
|
|
7: firmware
|
|
- name: cpqHoSwVerName
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.4
|
|
type: DisplayString
|
|
help: The name of this software item. - 1.3.6.1.4.1.232.11.2.7.2.1.4
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerDescription
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.5
|
|
type: DisplayString
|
|
help: The description of this software item. - 1.3.6.1.4.1.232.11.2.7.2.1.5
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerDate
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.6
|
|
type: OctetString
|
|
help: The date of the software item, if any - 1.3.6.1.4.1.232.11.2.7.2.1.6
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerLocation
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.7
|
|
type: DisplayString
|
|
help: The location of this software item on the server. - 1.3.6.1.4.1.232.11.2.7.2.1.7
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.8
|
|
type: DisplayString
|
|
help: An string that specifies the version of this item. - 1.3.6.1.4.1.232.11.2.7.2.1.8
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerVersionBinary
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.9
|
|
type: DisplayString
|
|
help: An string that specifies the version of this item based on the binary version
|
|
resource. - 1.3.6.1.4.1.232.11.2.7.2.1.9
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerAgentsVer
|
|
oid: 1.3.6.1.4.1.232.11.2.7.3
|
|
type: DisplayString
|
|
help: A string that specifies the version of the Insight Management Agents running
|
|
on the system. - 1.3.6.1.4.1.232.11.2.7.3
|
|
- name: cpqHoGenericData
|
|
oid: 1.3.6.1.4.1.232.11.2.8.1
|
|
type: DisplayString
|
|
help: Data for the generic trap. - 1.3.6.1.4.1.232.11.2.8.1
|
|
- name: cpqHoCriticalSoftwareUpdateData
|
|
oid: 1.3.6.1.4.1.232.11.2.8.2
|
|
type: DisplayString
|
|
help: Data for the Critical Software Update trap. - 1.3.6.1.4.1.232.11.2.8.2
|
|
- name: cpqHoSwPerfAppErrorDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.9.1
|
|
type: DisplayString
|
|
help: This string holds error information about the last application error that
|
|
occurred in the system. - 1.3.6.1.4.1.232.11.2.9.1
|
|
- name: cpqHoMibStatusArray
|
|
oid: 1.3.6.1.4.1.232.11.2.10.1
|
|
type: OctetString
|
|
help: The MIB Status Array is an array of MIB status structures - 1.3.6.1.4.1.232.11.2.10.1
|
|
- name: cpqHoConfigChangedDate
|
|
oid: 1.3.6.1.4.1.232.11.2.10.2
|
|
type: OctetString
|
|
help: The date/time when the agents were last loaded - 1.3.6.1.4.1.232.11.2.10.2
|
|
- name: cpqHoGUID
|
|
oid: 1.3.6.1.4.1.232.11.2.10.3
|
|
type: OctetString
|
|
help: The globally unique identifier of this physical server - 1.3.6.1.4.1.232.11.2.10.3
|
|
- name: cpqHoCodeServer
|
|
oid: 1.3.6.1.4.1.232.11.2.10.4
|
|
type: gauge
|
|
help: This item indicates how many code server shares are currently configured
|
|
on the system - 1.3.6.1.4.1.232.11.2.10.4
|
|
- name: cpqHoWebMgmtPort
|
|
oid: 1.3.6.1.4.1.232.11.2.10.5
|
|
type: gauge
|
|
help: This item indicates the port used by the Insight Web Agent - 1.3.6.1.4.1.232.11.2.10.5
|
|
- name: cpqHoGUIDCanonical
|
|
oid: 1.3.6.1.4.1.232.11.2.10.6
|
|
type: OctetString
|
|
help: The globally unique identifier in canonical format of this physical server
|
|
- 1.3.6.1.4.1.232.11.2.10.6
|
|
- name: cpqHoMibHealthStatusArray
|
|
oid: 1.3.6.1.4.1.232.11.2.10.7
|
|
type: OctetString
|
|
help: 'The MIB Health Status Array is an array of status values representing an
|
|
overall status in element 0 follwed by server and storage status values as follows:
|
|
Octet Element Field ======== ======= ========= 0 0 Aggregated Status of array
|
|
elements 1 1 Status of element 1 2 2 Status of element 2 - 1.3.6.1.4.1.232.11.2.10.7'
|
|
- name: cpqHoTrapFlags
|
|
oid: 1.3.6.1.4.1.232.11.2.11.1
|
|
type: gauge
|
|
help: The Trap Flags - 1.3.6.1.4.1.232.11.2.11.1
|
|
- name: cpqHoClientLastModified
|
|
oid: 1.3.6.1.4.1.232.11.2.12.1
|
|
type: OctetString
|
|
help: The date/time of the last modification to the client table - 1.3.6.1.4.1.232.11.2.12.1
|
|
- name: cpqHoClientDelete
|
|
oid: 1.3.6.1.4.1.232.11.2.12.2
|
|
type: DisplayString
|
|
help: Setting this variable to the name of a client in the client table will cause
|
|
that row in the table to be deleted - 1.3.6.1.4.1.232.11.2.12.2
|
|
- name: cpqHoClientIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.12.3.1.1
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientName
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.2
|
|
type: DisplayString
|
|
help: The Win95 machine name of this client. - 1.3.6.1.4.1.232.11.2.12.3.1.2
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientIpxAddress
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.3
|
|
type: OctetString
|
|
help: The IPX address for this client, all octets should be set to 0xff if this
|
|
machine does not support IPX - 1.3.6.1.4.1.232.11.2.12.3.1.3
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientIpAddress
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.4
|
|
type: InetAddressIPv4
|
|
help: The IP address for this client, all octets should be set to 0xff if this
|
|
machine does not support IP - 1.3.6.1.4.1.232.11.2.12.3.1.4
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientCommunity
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.5
|
|
type: DisplayString
|
|
help: A community name that can be used to query the client with SNMP - 1.3.6.1.4.1.232.11.2.12.3.1.5
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientID
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.6
|
|
type: OctetString
|
|
help: The unique identifier of this client. - 1.3.6.1.4.1.232.11.2.12.3.1.6
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoPhysicalMemorySize
|
|
oid: 1.3.6.1.4.1.232.11.2.13.1
|
|
type: gauge
|
|
help: Total amount of physical memory as seen by the OS (in megabytes) - 1.3.6.1.4.1.232.11.2.13.1
|
|
- name: cpqHoPhysicalMemoryFree
|
|
oid: 1.3.6.1.4.1.232.11.2.13.2
|
|
type: gauge
|
|
help: The amount of free physical memory (in megabytes) - 1.3.6.1.4.1.232.11.2.13.2
|
|
- name: cpqHoPagingMemorySize
|
|
oid: 1.3.6.1.4.1.232.11.2.13.3
|
|
type: gauge
|
|
help: Total virtual memory available from the OS (in megabytes) - 1.3.6.1.4.1.232.11.2.13.3
|
|
- name: cpqHoPagingMemoryFree
|
|
oid: 1.3.6.1.4.1.232.11.2.13.4
|
|
type: gauge
|
|
help: Available paging memory (in megabytes) - 1.3.6.1.4.1.232.11.2.13.4
|
|
- name: cpqHoBootPagingFileSize
|
|
oid: 1.3.6.1.4.1.232.11.2.13.5
|
|
type: DisplayString
|
|
help: The paging file size of the boot volume in the format xxxMB or xxxGB, where
|
|
xxx is the paging file size in that unit shown right after it - 1.3.6.1.4.1.232.11.2.13.5
|
|
- name: cpqHoBootPagingFileMinimumSize
|
|
oid: 1.3.6.1.4.1.232.11.2.13.6
|
|
type: DisplayString
|
|
help: Minimum paging file size of the boot volume required to save the memory
|
|
dump in the event of a system crash - 1.3.6.1.4.1.232.11.2.13.6
|
|
- name: cpqHoBootPagingFileVolumeFreeSpace
|
|
oid: 1.3.6.1.4.1.232.11.2.13.7
|
|
type: DisplayString
|
|
help: Free space of the boot volume required to save the memory dump in the event
|
|
of a system crash - 1.3.6.1.4.1.232.11.2.13.7
|
|
- name: cpqHoFwVerIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.1
|
|
type: gauge
|
|
help: Firmware Version Index - 1.3.6.1.4.1.232.11.2.14.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerCategory
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.2
|
|
type: gauge
|
|
help: Firmware Version Category. - 1.3.6.1.4.1.232.11.2.14.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: storage
|
|
3: nic
|
|
4: rib
|
|
5: system
|
|
- name: cpqHoFwVerDeviceType
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.3
|
|
type: gauge
|
|
help: Firmware Version Device Type. - 1.3.6.1.4.1.232.11.2.14.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internalArrayController
|
|
3: fibreArrayController
|
|
4: scsiController
|
|
5: fibreChannelTapeController
|
|
6: modularDataRouter
|
|
7: ideCdRomDrive
|
|
8: ideDiskDrive
|
|
9: scsiCdRom-ScsiAttached
|
|
10: scsiDiskDrive-ScsiAttached
|
|
11: scsiTapeDrive-ScsiAttached
|
|
12: scsiTapeLibrary-ScsiAttached
|
|
13: scsiDiskDrive-ArrayAttached
|
|
14: scsiTapeDrive-ArrayAttached
|
|
15: scsiTapeLibrary-ArrayAttached
|
|
16: scsiDiskDrive-FibreAttached
|
|
17: scsiTapeDrive-FibreAttached
|
|
18: scsiTapeLibrary-FibreAttached
|
|
19: scsiEnclosureBackplaneRom-ScsiAttached
|
|
20: scsiEnclosureBackplaneRom-ArrayAttached
|
|
21: scsiEnclosureBackplaneRom-FibreAttached
|
|
22: scsiEnclosureBackplaneRom-ra4x00
|
|
23: systemRom
|
|
24: networkInterfaceController
|
|
25: remoteInsightBoard
|
|
26: sasDiskDrive-SasAttached
|
|
27: sataDiskDrive-SataAttached
|
|
28: usbController
|
|
29: sasControllerAdapter
|
|
30: sataControllerAdapter
|
|
31: systemDevice
|
|
32: fibreChannelHba
|
|
33: convergedNetworkAdapter
|
|
34: ideController
|
|
- name: cpqHoFwVerDisplayName
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.4
|
|
type: DisplayString
|
|
help: Firmware Version Device Display Name - 1.3.6.1.4.1.232.11.2.14.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.5
|
|
type: DisplayString
|
|
help: Firmware Version - 1.3.6.1.4.1.232.11.2.14.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerLocation
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.6
|
|
type: DisplayString
|
|
help: Firmware Version Device Location - 1.3.6.1.4.1.232.11.2.14.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerXmlString
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.7
|
|
type: DisplayString
|
|
help: Firmware Version Xml String - 1.3.6.1.4.1.232.11.2.14.1.1.7
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerKeyString
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.8
|
|
type: DisplayString
|
|
help: Firmware Version Key String - 1.3.6.1.4.1.232.11.2.14.1.1.8
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerUpdateMethod
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.9
|
|
type: gauge
|
|
help: Firmware Version update method. - 1.3.6.1.4.1.232.11.2.14.1.1.9
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: noUpdate
|
|
3: softwareflash
|
|
4: replacePhysicalRom
|
|
- name: cpqHoHWInfoPlatform
|
|
oid: 1.3.6.1.4.1.232.11.2.15.1
|
|
type: gauge
|
|
help: Hardware platform type - 1.3.6.1.4.1.232.11.2.15.1
|
|
enum_values:
|
|
1: unknown
|
|
2: cellular
|
|
3: foundation
|
|
4: virtualMachine
|
|
5: serverBlade
|
|
- name: cpqPwrWarnType
|
|
oid: 1.3.6.1.4.1.232.11.2.16.1
|
|
type: DisplayString
|
|
help: Type of power reading on which the warning is based. - 1.3.6.1.4.1.232.11.2.16.1
|
|
- name: cpqPwrWarnThreshold
|
|
oid: 1.3.6.1.4.1.232.11.2.16.2
|
|
type: gauge
|
|
help: The threshold the power usage must exceed (in Watts). - 1.3.6.1.4.1.232.11.2.16.2
|
|
- name: cpqPwrWarnDuration
|
|
oid: 1.3.6.1.4.1.232.11.2.16.3
|
|
type: gauge
|
|
help: Duration that power usage must be exceeded before warning (in minutes).
|
|
- 1.3.6.1.4.1.232.11.2.16.3
|
|
- name: cpqSerialNum
|
|
oid: 1.3.6.1.4.1.232.11.2.16.4
|
|
type: DisplayString
|
|
help: Serial number of the server. - 1.3.6.1.4.1.232.11.2.16.4
|
|
- name: cpqServerUUID
|
|
oid: 1.3.6.1.4.1.232.11.2.16.5
|
|
type: DisplayString
|
|
help: Server UUID - 1.3.6.1.4.1.232.11.2.16.5
|
|
- name: cpqIdeMibRevMajor
|
|
oid: 1.3.6.1.4.1.232.14.1.1
|
|
type: gauge
|
|
help: The Major Revision level - 1.3.6.1.4.1.232.14.1.1
|
|
- name: cpqIdeMibRevMinor
|
|
oid: 1.3.6.1.4.1.232.14.1.2
|
|
type: gauge
|
|
help: The Minor Revision level - 1.3.6.1.4.1.232.14.1.2
|
|
- name: cpqIdeMibCondition
|
|
oid: 1.3.6.1.4.1.232.14.1.3
|
|
type: gauge
|
|
help: The overall condition - 1.3.6.1.4.1.232.14.1.3
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeOsCommonPollFreq
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.1
|
|
type: gauge
|
|
help: The Insight Agent`s polling frequency - 1.3.6.1.4.1.232.14.2.1.4.1
|
|
- name: cpqIdeOsCommonModuleIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.1
|
|
type: gauge
|
|
help: A unique index for this module description. - 1.3.6.1.4.1.232.14.2.1.4.2.1.1
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeOsCommonModuleName
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.2
|
|
type: DisplayString
|
|
help: The module name. - 1.3.6.1.4.1.232.14.2.1.4.2.1.2
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeOsCommonModuleVersion
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.3
|
|
type: DisplayString
|
|
help: The module version in XX.YY format - 1.3.6.1.4.1.232.14.2.1.4.2.1.3
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeOsCommonModuleDate
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.4
|
|
type: OctetString
|
|
help: The module date - 1.3.6.1.4.1.232.14.2.1.4.2.1.4
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeOsCommonModulePurpose
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.5
|
|
type: DisplayString
|
|
help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.14.2.1.4.2.1.5
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies each device - 1.3.6.1.4.1.232.14.2.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentModel
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.2
|
|
type: DisplayString
|
|
help: IDE Drive Model - 1.3.6.1.4.1.232.14.2.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentSerNum
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.3
|
|
type: DisplayString
|
|
help: IDE Drive Serial Number - 1.3.6.1.4.1.232.14.2.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentFWVers
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.4
|
|
type: DisplayString
|
|
help: IDE Firmware Version - 1.3.6.1.4.1.232.14.2.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.5
|
|
type: gauge
|
|
help: IDE Drive Condition - 1.3.6.1.4.1.232.14.2.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeIdentErrorNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.6
|
|
type: DisplayString
|
|
help: IDE Error Number - 1.3.6.1.4.1.232.14.2.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentType
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.7
|
|
type: gauge
|
|
help: IDE Device Type - 1.3.6.1.4.1.232.14.2.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: disk
|
|
3: tape
|
|
4: printer
|
|
5: processor
|
|
6: wormDrive
|
|
7: cd-rom
|
|
8: scanner
|
|
9: optical
|
|
10: jukeBox
|
|
11: commDev
|
|
- name: cpqIdeIdentTypeExtended
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.8
|
|
type: gauge
|
|
help: IDE Extended Device Type - 1.3.6.1.4.1.232.14.2.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: pdcd
|
|
3: removableDisk
|
|
- name: cpqIdeIdentCondition2
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.9
|
|
type: gauge
|
|
help: IDE Drive Condition - 1.3.6.1.4.1.232.14.2.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeIdentStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.10
|
|
type: gauge
|
|
help: IDE Drive Satus - 1.3.6.1.4.1.232.14.2.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: preFailureDegraded
|
|
4: ultraAtaDegraded
|
|
- name: cpqIdeIdentUltraAtaAvailability
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.11
|
|
type: gauge
|
|
help: This describes the availability of Ultra ATA transfers between this device
|
|
and the controller - 1.3.6.1.4.1.232.14.2.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: noNotSupportedByDeviceAndController
|
|
3: noNotSupportedByDevice
|
|
4: noNotSupportedByController
|
|
5: noDisabledInSetup
|
|
6: yesEnabledInSetup
|
|
- name: cpqIdeControllerIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerOverallCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.2
|
|
type: gauge
|
|
help: IDE Controller Overall Condition - 1.3.6.1.4.1.232.14.2.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeControllerModel
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.3
|
|
type: DisplayString
|
|
help: IDE Controller Model - 1.3.6.1.4.1.232.14.2.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerFwRev
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.4
|
|
type: DisplayString
|
|
help: IDE Controller Firmware Revision - 1.3.6.1.4.1.232.14.2.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerSlot
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.5
|
|
type: gauge
|
|
help: IDE Controller Slot - 1.3.6.1.4.1.232.14.2.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.6
|
|
type: gauge
|
|
help: IDE Channel Host Controller Status - 1.3.6.1.4.1.232.14.2.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
- name: cpqIdeControllerCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.7
|
|
type: gauge
|
|
help: IDE Controller Condition - 1.3.6.1.4.1.232.14.2.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeControllerSerialNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.8
|
|
type: DisplayString
|
|
help: IDE Controller Serial Number - 1.3.6.1.4.1.232.14.2.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerHwLocation
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.9
|
|
type: DisplayString
|
|
help: IDE Controller Hardware Location - 1.3.6.1.4.1.232.14.2.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerPciLocation
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.10
|
|
type: DisplayString
|
|
help: IDE Controller PCI Location - 1.3.6.1.4.1.232.14.2.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskControllerIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.4.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.2
|
|
type: gauge
|
|
help: An index that uniquely identifies each disk. - 1.3.6.1.4.1.232.14.2.4.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskModel
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.3
|
|
type: DisplayString
|
|
help: ATA Disk Model - 1.3.6.1.4.1.232.14.2.4.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskFwRev
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.4
|
|
type: DisplayString
|
|
help: ATA Disk Firmware Revision - 1.3.6.1.4.1.232.14.2.4.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskSerialNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.5
|
|
type: DisplayString
|
|
help: ATA Disk Serial Number - 1.3.6.1.4.1.232.14.2.4.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.6
|
|
type: gauge
|
|
help: ATA Disk Status - 1.3.6.1.4.1.232.14.2.4.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: smartError
|
|
4: failed
|
|
5: ssdWearOut
|
|
- name: cpqIdeAtaDiskCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.7
|
|
type: gauge
|
|
help: ATA Disk Condition - 1.3.6.1.4.1.232.14.2.4.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeAtaDiskCapacity
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.8
|
|
type: gauge
|
|
help: ATA Disk Capacity - 1.3.6.1.4.1.232.14.2.4.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskSmartEnabled
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.9
|
|
type: gauge
|
|
help: ATA Disk S.M.A.R.T Enabled? other(1) The agent cannot determine the state
|
|
of S.M.A.R.T - 1.3.6.1.4.1.232.14.2.4.1.1.9
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqIdeAtaDiskTransferMode
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.10
|
|
type: gauge
|
|
help: ATA Disk Transfer Mode - 1.3.6.1.4.1.232.14.2.4.1.1.10
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: pioMode0
|
|
3: pioMode1
|
|
4: pioMode2
|
|
5: pioMode3
|
|
6: pioMode4
|
|
7: dmaMode0
|
|
8: dmaMode1
|
|
9: dmaMode2
|
|
10: ultraDmaMode0
|
|
11: ultraDmaMode1
|
|
12: ultraDmaMode2
|
|
13: ultraDmaMode3
|
|
14: ultraDmaMode4
|
|
15: ultraDmaMode5
|
|
- name: cpqIdeAtaDiskChannel
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.11
|
|
type: gauge
|
|
help: ATA Disk Channel - 1.3.6.1.4.1.232.14.2.4.1.1.11
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: channel0
|
|
3: channel1
|
|
4: serial
|
|
- name: cpqIdeAtaDiskNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.12
|
|
type: gauge
|
|
help: ATA Disk Number - 1.3.6.1.4.1.232.14.2.4.1.1.12
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: device0
|
|
3: device1
|
|
4: sataDevice0
|
|
5: sataDevice1
|
|
6: sataDevice2
|
|
7: sataDevice3
|
|
8: sataDevice4
|
|
9: sataDevice5
|
|
10: sataDevice6
|
|
11: sataDevice7
|
|
21: bay1
|
|
22: bay2
|
|
23: bay3
|
|
24: bay4
|
|
25: bay5
|
|
26: bay6
|
|
27: bay7
|
|
28: bay8
|
|
29: bay9
|
|
30: bay10
|
|
31: bay11
|
|
32: bay12
|
|
33: bay13
|
|
34: bay14
|
|
- name: cpqIdeAtaDiskLogicalDriveMember
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.13
|
|
type: gauge
|
|
help: Logical Drive Membership? other(1) The agent cannot determine if the ATA
|
|
disk is part of a logical drive - 1.3.6.1.4.1.232.14.2.4.1.1.13
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqIdeAtaDiskIsSpare
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.14
|
|
type: gauge
|
|
help: ATA Disk Spare? other(1) The agent cannot determine if the ATA disk is a
|
|
spare - 1.3.6.1.4.1.232.14.2.4.1.1.14
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqIdeAtaDiskOsName
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.15
|
|
type: DisplayString
|
|
help: ATA Disk OS Name - 1.3.6.1.4.1.232.14.2.4.1.1.15
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskType
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.16
|
|
type: gauge
|
|
help: ATA Disk Type other(1) The agent cannot determine the disk type - 1.3.6.1.4.1.232.14.2.4.1.1.16
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ata
|
|
3: sata
|
|
- name: cpqIdeAtaDiskSataVersion
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.17
|
|
type: gauge
|
|
help: Physical Drive SATA Version - 1.3.6.1.4.1.232.14.2.4.1.1.17
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: sataOne
|
|
3: sataTwo
|
|
- name: cpqIdeAtaDiskMediaType
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.18
|
|
type: gauge
|
|
help: SATA Physical Drive Media Type - 1.3.6.1.4.1.232.14.2.4.1.1.18
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rotatingPlatters
|
|
3: solidState
|
|
- name: cpqIdeAtaDiskSSDWearStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.19
|
|
type: gauge
|
|
help: SATA Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.14.2.4.1.1.19
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: fiftySixDayThreshold
|
|
4: fivePercentThreshold
|
|
5: twoPercentThreshold
|
|
6: ssdWearOut
|
|
- name: cpqIdeAtaDiskPowerOnHours
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.20
|
|
type: counter
|
|
help: SATA Physical Drive Power On Hours - 1.3.6.1.4.1.232.14.2.4.1.1.20
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskSSDPercntEndrnceUsed
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.21
|
|
type: gauge
|
|
help: SATA Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.14.2.4.1.1.21
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskSSDEstTimeRemainingHours
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.22
|
|
type: counter
|
|
help: SATA Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.14.2.4.1.1.22
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskCurrTemperature
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.23
|
|
type: gauge
|
|
help: SATA Physical Drive Current Operating Temperature degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.23
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskTemperatureThreshold
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.24
|
|
type: gauge
|
|
help: SATA Physical Drive Maximum Operating Temperature in degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.24
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskMaximumOperatingTemp
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.25
|
|
type: gauge
|
|
help: SATA Physical Drive Maximum Operating Temperature, as specified by the manufacturer,
|
|
in degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.25
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskDestructiveOperatingTemp
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.26
|
|
type: gauge
|
|
help: SATA Physical Drive Destructive Operating Temperature, as specified by the
|
|
manufacturer, in degrees Celsius, which if exceeded can cause damage to the
|
|
drive - 1.3.6.1.4.1.232.14.2.4.1.1.26
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaEraseFailureType
|
|
oid: 1.3.6.1.4.1.232.14.2.4.2
|
|
type: gauge
|
|
help: The value specifies the secure erase status of SATA drive - 1.3.6.1.4.1.232.14.2.4.2
|
|
enum_values:
|
|
1: secureEraseFailed
|
|
2: secureEraseNotSupported
|
|
3: noEraseSupported
|
|
- name: cpqIdeAtapiDeviceControllerIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.5.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
- name: cpqIdeAtapiDeviceIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.2
|
|
type: gauge
|
|
help: An index that uniquely identifies each ATAPI device. - 1.3.6.1.4.1.232.14.2.5.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
- name: cpqIdeAtapiDeviceModel
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.3
|
|
type: DisplayString
|
|
help: ATAPI Device Model - 1.3.6.1.4.1.232.14.2.5.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
- name: cpqIdeAtapiDeviceFwRev
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.4
|
|
type: DisplayString
|
|
help: ATAPI Device Firmware Revision - 1.3.6.1.4.1.232.14.2.5.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
- name: cpqIdeAtapiDeviceType
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.5
|
|
type: gauge
|
|
help: ATAPI Device Type - 1.3.6.1.4.1.232.14.2.5.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: disk
|
|
3: tape
|
|
4: printer
|
|
5: processor
|
|
6: wormDrive
|
|
7: cd-rom
|
|
8: scanner
|
|
9: optical
|
|
10: jukeBox
|
|
11: commDev
|
|
- name: cpqIdeAtapiDeviceTypeExtended
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.6
|
|
type: gauge
|
|
help: ATAPI Extended Device Type - 1.3.6.1.4.1.232.14.2.5.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: pdcd
|
|
3: removableDisk
|
|
- name: cpqIdeAtapiDeviceChannel
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.7
|
|
type: gauge
|
|
help: ATAPI Device Channel - 1.3.6.1.4.1.232.14.2.5.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: channel0
|
|
3: channel1
|
|
- name: cpqIdeAtapiDeviceNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.8
|
|
type: gauge
|
|
help: ATAPI Device Number - 1.3.6.1.4.1.232.14.2.5.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: device0
|
|
3: device1
|
|
- name: cpqIdeLogicalDriveControllerIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.6.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.2
|
|
type: gauge
|
|
help: An index that uniquely identifies each logical drive. - 1.3.6.1.4.1.232.14.2.6.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveRaidLevel
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.3
|
|
type: gauge
|
|
help: IDE Logical Drive RAID Level - 1.3.6.1.4.1.232.14.2.6.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: raid0
|
|
3: raid1
|
|
4: raid0plus1
|
|
5: raid5
|
|
6: raid15
|
|
7: volume
|
|
- name: cpqIdeLogicalDriveCapacity
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.4
|
|
type: gauge
|
|
help: IDE Logical Drive Capacity - 1.3.6.1.4.1.232.14.2.6.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.5
|
|
type: gauge
|
|
help: IDE Logical Drive Status - 1.3.6.1.4.1.232.14.2.6.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: rebuilding
|
|
5: failed
|
|
- name: cpqIdeLogicalDriveCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.6
|
|
type: gauge
|
|
help: IDE Logical Drive Condition - 1.3.6.1.4.1.232.14.2.6.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeLogicalDriveDiskIds
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.7
|
|
type: OctetString
|
|
help: IDE Logical Drive Disk ID list - 1.3.6.1.4.1.232.14.2.6.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveStripeSize
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.8
|
|
type: gauge
|
|
help: IDE Logical Drive Stripe Size - 1.3.6.1.4.1.232.14.2.6.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveSpareIds
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.9
|
|
type: OctetString
|
|
help: IDE Logical Drive Spare ID list - 1.3.6.1.4.1.232.14.2.6.1.1.9
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveRebuildingDisk
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.10
|
|
type: gauge
|
|
help: IDE Logical Drive Rebuilding Disk - 1.3.6.1.4.1.232.14.2.6.1.1.10
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveOsName
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.11
|
|
type: DisplayString
|
|
help: IDE Logical Drive OS Name - 1.3.6.1.4.1.232.14.2.6.1.1.11
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.1
|
|
type: gauge
|
|
help: Array Controller Index - 1.3.6.1.4.1.232.3.2.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrModel
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.2
|
|
type: gauge
|
|
help: Array Controller Model - 1.3.6.1.4.1.232.3.2.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ida
|
|
3: idaExpansion
|
|
4: ida-2
|
|
5: smart
|
|
6: smart-2e
|
|
7: smart-2p
|
|
8: smart-2sl
|
|
9: smart-3100es
|
|
10: smart-3200
|
|
11: smart-2dh
|
|
12: smart-221
|
|
13: sa-4250es
|
|
14: sa-4200
|
|
15: sa-integrated
|
|
16: sa-431
|
|
17: sa-5300
|
|
18: raidLc2
|
|
19: sa-5i
|
|
20: sa-532
|
|
21: sa-5312
|
|
22: sa-641
|
|
23: sa-642
|
|
24: sa-6400
|
|
25: sa-6400em
|
|
26: sa-6i
|
|
27: sa-generic
|
|
29: sa-p600
|
|
30: sa-p400
|
|
31: sa-e200
|
|
32: sa-e200i
|
|
33: sa-p400i
|
|
34: sa-p800
|
|
35: sa-e500
|
|
36: sa-p700m
|
|
37: sa-p212
|
|
38: sa-p410
|
|
39: sa-p410i
|
|
40: sa-p411
|
|
41: sa-b110i
|
|
42: sa-p712m
|
|
43: sa-p711m
|
|
44: sa-p812
|
|
45: sw-1210m
|
|
46: sa-p220i
|
|
47: sa-p222
|
|
48: sa-p420
|
|
49: sa-p420i
|
|
50: sa-p421
|
|
51: sa-b320i
|
|
52: sa-p822
|
|
53: sa-p721m
|
|
54: sa-b120i
|
|
55: hps-1224
|
|
56: hps-1228
|
|
57: hps-1228m
|
|
58: sa-p822se
|
|
59: hps-1224e
|
|
60: hps-1228e
|
|
61: hps-1228em
|
|
62: sa-p230i
|
|
63: sa-p430i
|
|
64: sa-p430
|
|
65: sa-p431
|
|
66: sa-p731m
|
|
67: sa-p830i
|
|
68: sa-p830
|
|
69: sa-p831
|
|
70: sa-p530
|
|
71: sa-p531
|
|
72: sa-p244br
|
|
73: sa-p246br
|
|
74: sa-p440
|
|
75: sa-p440ar
|
|
76: sa-p441
|
|
77: sa-p741m
|
|
78: sa-p840
|
|
79: sa-p841
|
|
80: sh-h240ar
|
|
81: sh-h244br
|
|
82: sh-h240
|
|
83: sh-h241
|
|
84: sa-b140i
|
|
85: sh-generic
|
|
86: sa-p240nr
|
|
87: sh-h240nr
|
|
88: sa-p840ar
|
|
89: sa-p542d
|
|
90: s100i
|
|
91: e208i-p
|
|
92: e208i-a
|
|
93: e208i-c
|
|
94: e208e-p
|
|
95: p204i-b
|
|
96: p204i-c
|
|
97: p408i-p
|
|
98: p408i-a
|
|
99: p408e-p
|
|
100: p408i-c
|
|
101: p408e-m
|
|
102: p416ie-m
|
|
103: p816i-a
|
|
104: p408i-sb
|
|
- name: cpqDaCntlrFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.3
|
|
type: DisplayString
|
|
help: Array Controller Firmware Revision - 1.3.6.1.4.1.232.3.2.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrStndIntr
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.4
|
|
type: gauge
|
|
help: The status of the Standard Interface - 1.3.6.1.4.1.232.3.2.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: primary
|
|
3: secondary
|
|
4: disabled
|
|
5: unavailable
|
|
- name: cpqDaCntlrSlot
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.5
|
|
type: gauge
|
|
help: Array Controller Slot - 1.3.6.1.4.1.232.3.2.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.6
|
|
type: gauge
|
|
help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaCntlrProductRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.7
|
|
type: DisplayString
|
|
help: Array Controller Product Revision - 1.3.6.1.4.1.232.3.2.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrPartnerSlot
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.8
|
|
type: gauge
|
|
help: Array Controller Partner Slot - 1.3.6.1.4.1.232.3.2.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrCurrentRole
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.9
|
|
type: gauge
|
|
help: Array Controller Current Role - 1.3.6.1.4.1.232.3.2.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notDuplexed
|
|
3: active
|
|
4: backup
|
|
5: asymActiveActive
|
|
- name: cpqDaCntlrBoardStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.10
|
|
type: gauge
|
|
help: Array Controller Board Status - 1.3.6.1.4.1.232.3.2.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: generalFailure
|
|
4: cableProblem
|
|
5: poweredOff
|
|
6: cacheModuleMissing
|
|
- name: cpqDaCntlrPartnerBoardStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.11
|
|
type: gauge
|
|
help: Array Controller Partner Board Status - 1.3.6.1.4.1.232.3.2.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: generalFailure
|
|
4: cableProblem
|
|
5: poweredOff
|
|
- name: cpqDaCntlrBoardCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.12
|
|
type: gauge
|
|
help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.12
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaCntlrPartnerBoardCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.13
|
|
type: gauge
|
|
help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.13
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaCntlrDriveOwnership
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.14
|
|
type: gauge
|
|
help: Array Controller Drive Ownership - 1.3.6.1.4.1.232.3.2.2.1.1.14
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: owner
|
|
3: notOwner
|
|
- name: cpqDaCntlrSerialNumber
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.15
|
|
type: DisplayString
|
|
help: Array Controller Serial Number - 1.3.6.1.4.1.232.3.2.2.1.1.15
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrRedundancyType
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.16
|
|
type: gauge
|
|
help: Array Controller Redundancy Type - 1.3.6.1.4.1.232.3.2.2.1.1.16
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notRedundant
|
|
3: driverDuplexing
|
|
4: fwActiveStandby
|
|
5: fwPrimarySecondary
|
|
6: fwActiveActive
|
|
- name: cpqDaCntlrRedundancyError
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.17
|
|
type: gauge
|
|
help: Array Controller Redundancy Error - 1.3.6.1.4.1.232.3.2.2.1.1.17
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: noFailure
|
|
3: noRedundantController
|
|
4: differentHardware
|
|
5: noLink
|
|
6: differentFirmware
|
|
7: differentCache
|
|
8: otherCacheFailure
|
|
9: noDrives
|
|
10: otherNoDrives
|
|
11: unsupportedDrives
|
|
12: expandInProgress
|
|
- name: cpqDaCntlrAccessModuleStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.18
|
|
type: gauge
|
|
help: Array Controller RAID ADG Enabler Module Status - 1.3.6.1.4.1.232.3.2.2.1.1.18
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notPresent
|
|
4: badSignature
|
|
5: badChecksum
|
|
6: fullyFunctional
|
|
7: upgradeFirmware
|
|
- name: cpqDaCntlrDaughterBoardType
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.19
|
|
type: gauge
|
|
help: Array Controller Daughter Board Type - 1.3.6.1.4.1.232.3.2.2.1.1.19
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notPresent
|
|
4: scsiBoardPresent
|
|
5: fibreBoardPresent
|
|
6: arrayExpansionModulePresent
|
|
- name: cpqDaCntlrHwLocation
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.20
|
|
type: DisplayString
|
|
help: A text description of the hardware location of the controller - 1.3.6.1.4.1.232.3.2.2.1.1.20
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrNumberOfBuses
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.21
|
|
type: gauge
|
|
help: Array Controller Number of Buses - 1.3.6.1.4.1.232.3.2.2.1.1.21
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrBlinkTime
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.22
|
|
type: counter
|
|
help: Controller Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.2.1.1.22
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrRebuildPriority
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.23
|
|
type: gauge
|
|
help: Array Controller Rebuild Priority - 1.3.6.1.4.1.232.3.2.2.1.1.23
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: low
|
|
3: medium
|
|
4: high
|
|
5: mediumHigh
|
|
- name: cpqDaCntlrExpandPriority
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.24
|
|
type: gauge
|
|
help: Array Controller Expand Priority - 1.3.6.1.4.1.232.3.2.2.1.1.24
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: low
|
|
3: medium
|
|
4: high
|
|
- name: cpqDaCntlrNumberOfInternalPorts
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.25
|
|
type: gauge
|
|
help: Array Controller Number of Internal Ports - 1.3.6.1.4.1.232.3.2.2.1.1.25
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrNumberOfExternalPorts
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.26
|
|
type: gauge
|
|
help: Array Controller Number of External Ports - 1.3.6.1.4.1.232.3.2.2.1.1.26
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrDriveWriteCacheState
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.27
|
|
type: gauge
|
|
help: Array Controller Drive Write Cache State - 1.3.6.1.4.1.232.3.2.2.1.1.27
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: disabled
|
|
3: enabled
|
|
- name: cpqDaCntlrPartnerSerialNumber
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.28
|
|
type: DisplayString
|
|
help: Array Controller Partner Serial Number - 1.3.6.1.4.1.232.3.2.2.1.1.28
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrOptionRomRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.29
|
|
type: DisplayString
|
|
help: Array Controller Option ROM Revision - 1.3.6.1.4.1.232.3.2.2.1.1.29
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrHbaFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.30
|
|
type: DisplayString
|
|
help: Array Controller HBA Firmware Revision - 1.3.6.1.4.1.232.3.2.2.1.1.30
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrHBAModeOptionRomRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.31
|
|
type: DisplayString
|
|
help: Array Controller HBA Mode Option Rom Revision - 1.3.6.1.4.1.232.3.2.2.1.1.31
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrCurrentTemp
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.32
|
|
type: gauge
|
|
help: Array Controller Current Temperature - 1.3.6.1.4.1.232.3.2.2.1.1.32
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrLastLockupCode
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.33
|
|
type: gauge
|
|
help: Array Controller Last Lockup Code - 1.3.6.1.4.1.232.3.2.2.1.1.33
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrEncryptionStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.34
|
|
type: gauge
|
|
help: Array Controller Encryption Status - 1.3.6.1.4.1.232.3.2.2.1.1.34
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notEnabled
|
|
3: enabledLocalKeyMode
|
|
4: enabledRemoteKeyManagerMode
|
|
- name: cpqDaCntlrASICEncptSelfTestStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.35
|
|
type: gauge
|
|
help: Array Controller ASIC Encryption Self Test Status - 1.3.6.1.4.1.232.3.2.2.1.1.35
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: selfTestsPass
|
|
3: selfTestsFailed
|
|
- name: cpqDaCntlrEncryptCspNvramStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.36
|
|
type: gauge
|
|
help: Array Controller Encryption Critical Security Parameter NVRAM Status - 1.3.6.1.4.1.232.3.2.2.1.1.36
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: detectionFailed
|
|
- name: cpqDaCntlrEncryptCryptoOfficerPwdSetStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.37
|
|
type: gauge
|
|
help: Array Controller Encryption Crypto Officer Password Set Status - 1.3.6.1.4.1.232.3.2.2.1.1.37
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrEncryptCntlrPwdSetStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.38
|
|
type: gauge
|
|
help: Array Controller Encryption Controller Password Set Status - 1.3.6.1.4.1.232.3.2.2.1.1.38
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrEncryptCntlrPwdAvailStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.39
|
|
type: gauge
|
|
help: Array Controller Encryption Controller Password Availability Status - 1.3.6.1.4.1.232.3.2.2.1.1.39
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: passwordMissing
|
|
3: passwordActive
|
|
- name: cpqDaCntlrUnencryptedLogDrvCreationPolicy
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.40
|
|
type: gauge
|
|
help: Array Controller Unencrypted Logical Drive Creation Policy - 1.3.6.1.4.1.232.3.2.2.1.1.40
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrEncryptedLogDrvCreationPolicy
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.41
|
|
type: gauge
|
|
help: Array Controller Encrypted Logical Drive Creation Policy - 1.3.6.1.4.1.232.3.2.2.1.1.41
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrEncryptFWLockStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.42
|
|
type: gauge
|
|
help: Array Controller Encryption Firmware Lock Status - 1.3.6.1.4.1.232.3.2.2.1.1.42
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrOperatingMode
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.43
|
|
type: gauge
|
|
help: Array Controller Operating Mode - 1.3.6.1.4.1.232.3.2.2.1.1.43
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: smartArrayMode
|
|
3: smartHbaMode
|
|
4: mixedMode
|
|
- name: cpqDaLogDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.1
|
|
type: gauge
|
|
help: Drive Array Logical Drive Controller Index - 1.3.6.1.4.1.232.3.2.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.2
|
|
type: gauge
|
|
help: Drive Array Logical Drive Index - 1.3.6.1.4.1.232.3.2.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvFaultTol
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.3
|
|
type: gauge
|
|
help: Logical Drive Fault Tolerance - 1.3.6.1.4.1.232.3.2.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: none
|
|
3: mirroring
|
|
4: dataGuard
|
|
5: distribDataGuard
|
|
7: advancedDataGuard
|
|
8: raid50
|
|
9: raid60
|
|
10: raid1Adm
|
|
11: raid10Adm
|
|
12: raid10
|
|
- name: cpqDaLogDrvStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.4
|
|
type: gauge
|
|
help: Logical Drive Status - 1.3.6.1.4.1.232.3.2.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: unconfigured
|
|
5: recovering
|
|
6: readyForRebuild
|
|
7: rebuilding
|
|
8: wrongDrive
|
|
9: badConnect
|
|
10: overheating
|
|
11: shutdown
|
|
12: expanding
|
|
13: notAvailable
|
|
14: queuedForExpansion
|
|
15: multipathAccessDegraded
|
|
16: erasing
|
|
17: predictiveSpareRebuildReady
|
|
18: rapidParityInitInProgress
|
|
19: rapidParityInitPending
|
|
20: noAccessEncryptedNoCntlrKey
|
|
21: unencryptedToEncryptedInProgress
|
|
22: newLogDrvKeyRekeyInProgress
|
|
23: noAccessEncryptedCntlrEncryptnNotEnbld
|
|
24: unencryptedToEncryptedNotStarted
|
|
25: newLogDrvKeyRekeyRequestReceived
|
|
- name: cpqDaLogDrvAutoRel
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.5
|
|
type: gauge
|
|
help: Array Controller Logical Drive Auto-Reliability Delay - 1.3.6.1.4.1.232.3.2.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvRebuildBlks
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.6
|
|
type: counter
|
|
help: Logical Drive Rebuild Blocks Remaining - 1.3.6.1.4.1.232.3.2.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvHasAccel
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.7
|
|
type: gauge
|
|
help: Logical Drive Has Cache Module Board - 1.3.6.1.4.1.232.3.2.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unavailable
|
|
3: enabled
|
|
4: disabled
|
|
- name: cpqDaLogDrvAvailSpares
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.8
|
|
type: OctetString
|
|
help: Drive Array Logical Drive Available Spares - 1.3.6.1.4.1.232.3.2.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvSize
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.9
|
|
type: gauge
|
|
help: Logical Drive Size - 1.3.6.1.4.1.232.3.2.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvPhyDrvIDs
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.10
|
|
type: OctetString
|
|
help: Drive Array Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.3.2.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.11
|
|
type: gauge
|
|
help: The Logical Drive condition - 1.3.6.1.4.1.232.3.2.3.1.1.11
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaLogDrvPercentRebuild
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.12
|
|
type: gauge
|
|
help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.3.2.3.1.1.12
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvStripeSize
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.13
|
|
type: gauge
|
|
help: Logical Drive Stripe Size - 1.3.6.1.4.1.232.3.2.3.1.1.13
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvOsName
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.14
|
|
type: DisplayString
|
|
help: Logical Drive OS Name - 1.3.6.1.4.1.232.3.2.3.1.1.14
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvBlinkTime
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.15
|
|
type: counter
|
|
help: Logical Drive Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.3.1.1.15
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvSpareReplaceMap
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.16
|
|
type: OctetString
|
|
help: Logical Drive Spare To Replacement Drive Map - 1.3.6.1.4.1.232.3.2.3.1.1.16
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvRebuildingPhyDrv
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.17
|
|
type: gauge
|
|
help: Logical Drive Physical Drive Rebuilding Index - 1.3.6.1.4.1.232.3.2.3.1.1.17
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvMultipathAccess
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.18
|
|
type: gauge
|
|
help: Logical Drive Multi-path Access - 1.3.6.1.4.1.232.3.2.3.1.1.18
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notConfigured
|
|
4: pathRedundant
|
|
5: noRedundantPath
|
|
- name: cpqDaLogDrvNmbrOfParityGroups
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.19
|
|
type: gauge
|
|
help: Logical Drive Number Of Parity Groups - 1.3.6.1.4.1.232.3.2.3.1.1.19
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvSplitMirrorBackupLogDrv
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.20
|
|
type: gauge
|
|
help: Logical Drive Split Mirror Backup Logical Drive - 1.3.6.1.4.1.232.3.2.3.1.1.20
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: isNotBackupLogicalDrive
|
|
3: isBackupLogicalDrive
|
|
- name: cpqDaLogDrvCacheVolAccelAssocType
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.21
|
|
type: gauge
|
|
help: Logical Drive Cache Volume Accelerator Association Type - 1.3.6.1.4.1.232.3.2.3.1.1.21
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: nonMember
|
|
3: logicalDriveMember
|
|
4: cacheVolumeMember
|
|
- name: cpqDaLogDrvCacheVolIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.22
|
|
type: gauge
|
|
help: Logical Drive Cache Volume Index - 1.3.6.1.4.1.232.3.2.3.1.1.22
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvRPIPercentComplete
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.23
|
|
type: gauge
|
|
help: Logical Drive Rapid Parity Initialization Percent Complete - 1.3.6.1.4.1.232.3.2.3.1.1.23
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvSSDSmartPathStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.24
|
|
type: gauge
|
|
help: Logical Drive SSD Smart Path Status - 1.3.6.1.4.1.232.3.2.3.1.1.24
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: updateDriver
|
|
3: ssdSmartPathDisabled
|
|
4: ssdSmartPathEnabled
|
|
- name: cpqDaLogDrvEncryptionStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.25
|
|
type: gauge
|
|
help: Logical Drive Encryption Status - 1.3.6.1.4.1.232.3.2.3.1.1.25
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: encrypted
|
|
3: notEncrypted
|
|
- name: cpqDaPhyDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.1
|
|
type: gauge
|
|
help: Drive Array Physical Drive Controller Index - 1.3.6.1.4.1.232.3.2.5.1.1.1
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.2
|
|
type: gauge
|
|
help: Drive Array Physical Drive Index - 1.3.6.1.4.1.232.3.2.5.1.1.2
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvModel
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.3
|
|
type: DisplayString
|
|
help: Physical Drive Model - 1.3.6.1.4.1.232.3.2.5.1.1.3
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.4
|
|
type: DisplayString
|
|
help: Physical Drive Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.4
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBay
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.5
|
|
type: gauge
|
|
help: Physical Drive Bay Location - 1.3.6.1.4.1.232.3.2.5.1.1.5
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.6
|
|
type: gauge
|
|
help: Physical Drive Status - 1.3.6.1.4.1.232.3.2.5.1.1.6
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: predictiveFailure
|
|
5: erasing
|
|
6: eraseDone
|
|
7: eraseQueued
|
|
8: ssdWearOut
|
|
9: notAuthenticated
|
|
- name: cpqDaPhyDrvFactReallocs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.7
|
|
type: gauge
|
|
help: This shows the number of spare sectors available for remapping at the time
|
|
the physical drive was shipped - 1.3.6.1.4.1.232.3.2.5.1.1.7
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvUsedReallocs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.8
|
|
type: counter
|
|
help: Physical Drive Used Reallocated Sectors - 1.3.6.1.4.1.232.3.2.5.1.1.8
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvRefHours
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.9
|
|
type: counter
|
|
help: Reference Time in hours - 1.3.6.1.4.1.232.3.2.5.1.1.9
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHReads
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.10
|
|
type: counter
|
|
help: Sectors Read (high) - 1.3.6.1.4.1.232.3.2.5.1.1.10
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvReads
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.11
|
|
type: counter
|
|
help: Sectors Read (low) - 1.3.6.1.4.1.232.3.2.5.1.1.11
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHWrites
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.12
|
|
type: counter
|
|
help: Sectors Written (high) - 1.3.6.1.4.1.232.3.2.5.1.1.12
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvWrites
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.13
|
|
type: counter
|
|
help: Sectors Written (low) - 1.3.6.1.4.1.232.3.2.5.1.1.13
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHSeeks
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.14
|
|
type: counter
|
|
help: Total Seeks (high) - 1.3.6.1.4.1.232.3.2.5.1.1.14
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSeeks
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.15
|
|
type: counter
|
|
help: Total Seeks (low) - 1.3.6.1.4.1.232.3.2.5.1.1.15
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHardReadErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.16
|
|
type: counter
|
|
help: Hard Read Errors - 1.3.6.1.4.1.232.3.2.5.1.1.16
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvRecvReadErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.17
|
|
type: counter
|
|
help: Recovered Read Errors - 1.3.6.1.4.1.232.3.2.5.1.1.17
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHardWriteErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.18
|
|
type: counter
|
|
help: Hard Write Errors - 1.3.6.1.4.1.232.3.2.5.1.1.18
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvRecvWriteErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.19
|
|
type: counter
|
|
help: Recovered Write Errors - 1.3.6.1.4.1.232.3.2.5.1.1.19
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHSeekErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.20
|
|
type: counter
|
|
help: Seek Errors (High) - 1.3.6.1.4.1.232.3.2.5.1.1.20
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSeekErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.21
|
|
type: counter
|
|
help: Seek Errors (low) - 1.3.6.1.4.1.232.3.2.5.1.1.21
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSpinupTime
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.22
|
|
type: gauge
|
|
help: Spin up Time in tenths of seconds - 1.3.6.1.4.1.232.3.2.5.1.1.22
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFunctTest1
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.23
|
|
type: gauge
|
|
help: Functional Test 1 - 1.3.6.1.4.1.232.3.2.5.1.1.23
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFunctTest2
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.24
|
|
type: gauge
|
|
help: Functional Test 2 - 1.3.6.1.4.1.232.3.2.5.1.1.24
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFunctTest3
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.25
|
|
type: gauge
|
|
help: Functional Test 3 - 1.3.6.1.4.1.232.3.2.5.1.1.25
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvDrqTimeouts
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.26
|
|
type: counter
|
|
help: DRQ Timeouts - 1.3.6.1.4.1.232.3.2.5.1.1.26
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvOtherTimeouts
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.27
|
|
type: counter
|
|
help: Other Timeouts - 1.3.6.1.4.1.232.3.2.5.1.1.27
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSpinupRetries
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.28
|
|
type: counter
|
|
help: Spin up Retries - 1.3.6.1.4.1.232.3.2.5.1.1.28
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBadRecvReads
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.29
|
|
type: counter
|
|
help: Recovery Failed (Bad) Read Error - 1.3.6.1.4.1.232.3.2.5.1.1.29
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBadRecvWrites
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.30
|
|
type: counter
|
|
help: Recovery Failed (Bad) Write Error - 1.3.6.1.4.1.232.3.2.5.1.1.30
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFormatErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.31
|
|
type: counter
|
|
help: Format Error - 1.3.6.1.4.1.232.3.2.5.1.1.31
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvPostErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.32
|
|
type: counter
|
|
help: Power On Self Test (Post) Error - 1.3.6.1.4.1.232.3.2.5.1.1.32
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvNotReadyErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.33
|
|
type: counter
|
|
help: Drive Not Ready Errors - 1.3.6.1.4.1.232.3.2.5.1.1.33
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvReallocAborts
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.34
|
|
type: counter
|
|
help: Physical Drive Reallocation Aborts - 1.3.6.1.4.1.232.3.2.5.1.1.34
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvThreshPassed
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.35
|
|
type: gauge
|
|
help: Physical Drive Factory Threshold Passed (Exceeded) - 1.3.6.1.4.1.232.3.2.5.1.1.35
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: "false"
|
|
2: "true"
|
|
- name: cpqDaPhyDrvHasMonInfo
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.36
|
|
type: gauge
|
|
help: Physical Drive Has Monitor Information - 1.3.6.1.4.1.232.3.2.5.1.1.36
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: "false"
|
|
2: "true"
|
|
- name: cpqDaPhyDrvCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.37
|
|
type: gauge
|
|
help: The condition of the device - 1.3.6.1.4.1.232.3.2.5.1.1.37
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaPhyDrvHotPlugs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.38
|
|
type: counter
|
|
help: Physical Drive Hot Plug Count - 1.3.6.1.4.1.232.3.2.5.1.1.38
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvMediaErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.39
|
|
type: counter
|
|
help: Physical Drive Media Failure Count - 1.3.6.1.4.1.232.3.2.5.1.1.39
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHardwareErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.40
|
|
type: counter
|
|
help: Physical Drive Hardware Error Count - 1.3.6.1.4.1.232.3.2.5.1.1.40
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvAbortedCmds
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.41
|
|
type: counter
|
|
help: Physical Drive Aborted Command Failures - 1.3.6.1.4.1.232.3.2.5.1.1.41
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSpinUpErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.42
|
|
type: counter
|
|
help: Physical Drive Spin-Up Failure Count - 1.3.6.1.4.1.232.3.2.5.1.1.42
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBadTargetErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.43
|
|
type: counter
|
|
help: Physical Drive Bad Target Count - 1.3.6.1.4.1.232.3.2.5.1.1.43
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvLocation
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.44
|
|
type: gauge
|
|
help: Drive Physical Location - 1.3.6.1.4.1.232.3.2.5.1.1.44
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
4: proLiant
|
|
- name: cpqDaPhyDrvSize
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.45
|
|
type: gauge
|
|
help: Physical Drive Size in MB - 1.3.6.1.4.1.232.3.2.5.1.1.45
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBusFaults
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.46
|
|
type: counter
|
|
help: Physical Drive Bus Fault Count - 1.3.6.1.4.1.232.3.2.5.1.1.46
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvIrqDeglitches
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.47
|
|
type: counter
|
|
help: Physical Drive IRQ Deglitch Count - 1.3.6.1.4.1.232.3.2.5.1.1.47
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHotPlug
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.48
|
|
type: gauge
|
|
help: Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.3.2.5.1.1.48
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: hotPlug
|
|
3: nonHotPlug
|
|
- name: cpqDaPhyDrvPlacement
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.49
|
|
type: gauge
|
|
help: Physical Drive Placement - 1.3.6.1.4.1.232.3.2.5.1.1.49
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
- name: cpqDaPhyDrvBusNumber
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.50
|
|
type: gauge
|
|
help: Physical Drive SCSI Bus Number - 1.3.6.1.4.1.232.3.2.5.1.1.50
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSerialNum
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.51
|
|
type: DisplayString
|
|
help: Physical Drive Serial Number - 1.3.6.1.4.1.232.3.2.5.1.1.51
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvPreFailMonitoring
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.52
|
|
type: gauge
|
|
help: Drive Array Physical Drive Predictive Failure Monitoring - 1.3.6.1.4.1.232.3.2.5.1.1.52
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notAvailable
|
|
3: available
|
|
- name: cpqDaPhyDrvCurrentWidth
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.53
|
|
type: gauge
|
|
help: Drive Array Physical Drive Current Width - 1.3.6.1.4.1.232.3.2.5.1.1.53
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: narrow
|
|
3: wide16
|
|
- name: cpqDaPhyDrvCurrentSpeed
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.54
|
|
type: gauge
|
|
help: Drive Array Physical Drive Current Data Transfer Speed - 1.3.6.1.4.1.232.3.2.5.1.1.54
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: asynchronous
|
|
3: fast
|
|
4: ultra
|
|
5: ultra2
|
|
6: ultra3
|
|
7: ultra320
|
|
- name: cpqDaPhyDrvFailureCode
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.55
|
|
type: gauge
|
|
help: Drive Array Physical Drive Failure Code - 1.3.6.1.4.1.232.3.2.5.1.1.55
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBlinkTime
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.56
|
|
type: counter
|
|
help: Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.5.1.1.56
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSmartStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.57
|
|
type: gauge
|
|
help: Physical Drive S.M.A.R.T Status - 1.3.6.1.4.1.232.3.2.5.1.1.57
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: replaceDrive
|
|
4: replaceDriveSSDWearOut
|
|
- name: cpqDaPhyDrvConfigurationStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.58
|
|
type: gauge
|
|
help: Physical Drive Configuration Status - 1.3.6.1.4.1.232.3.2.5.1.1.58
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: configured
|
|
3: notConfigured
|
|
- name: cpqDaPhyDrvRotationalSpeed
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.59
|
|
type: gauge
|
|
help: Drive Array Physical Drive Rotational Speed - 1.3.6.1.4.1.232.3.2.5.1.1.59
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rpm7200
|
|
3: rpm10K
|
|
4: rpm15K
|
|
5: rpmSsd
|
|
- name: cpqDaPhyDrvType
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.60
|
|
type: gauge
|
|
help: Physical Drive Type - 1.3.6.1.4.1.232.3.2.5.1.1.60
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: parallelScsi
|
|
3: sata
|
|
4: sas
|
|
- name: cpqDaPhyDrvSataVersion
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.61
|
|
type: gauge
|
|
help: Physical Drive SATA Version - 1.3.6.1.4.1.232.3.2.5.1.1.61
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: sataOne
|
|
3: sataTwo
|
|
- name: cpqDaPhyDrvHostConnector
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.62
|
|
type: DisplayString
|
|
help: Physical Drive Host Connector - 1.3.6.1.4.1.232.3.2.5.1.1.62
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBoxOnConnector
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.63
|
|
type: gauge
|
|
help: Physical Drive Box on Connector - 1.3.6.1.4.1.232.3.2.5.1.1.63
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvLocationString
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.64
|
|
type: DisplayString
|
|
help: Physical Drive Location String - 1.3.6.1.4.1.232.3.2.5.1.1.64
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvNegotiatedLinkRate
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.65
|
|
type: gauge
|
|
help: Drive Array Physical Drive Negotiated Link Rate - 1.3.6.1.4.1.232.3.2.5.1.1.65
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rate-1-5
|
|
3: rate-3-0
|
|
4: rate-6-0
|
|
5: rate-12-0
|
|
- name: cpqDaPhyDrvNcqSupport
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.66
|
|
type: gauge
|
|
help: Drive Array Physical Drive Native Command Queueing - 1.3.6.1.4.1.232.3.2.5.1.1.66
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: noControllerSupport
|
|
3: noDriveSupport
|
|
4: ncqDisabled
|
|
5: ncqEnabled
|
|
- name: cpqDaPhyDrvPhyCount
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.67
|
|
type: gauge
|
|
help: Drive Array Physical Drive PHY Count - 1.3.6.1.4.1.232.3.2.5.1.1.67
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvMultipathAccess
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.68
|
|
type: gauge
|
|
help: Drive Array Physical Drive Multi-path Access Status - 1.3.6.1.4.1.232.3.2.5.1.1.68
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notConfigured
|
|
4: pathRedundant
|
|
5: noRedundantPath
|
|
6: driveFailed
|
|
- name: cpqDaPhyDrvMediaType
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.69
|
|
type: gauge
|
|
help: Drive Array Physical Drive Media Type - 1.3.6.1.4.1.232.3.2.5.1.1.69
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rotatingPlatters
|
|
3: solidState
|
|
4: smr
|
|
- name: cpqDaPhyDrvCurrentTemperature
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.70
|
|
type: gauge
|
|
help: Drive Array Physical Drive Current Temperature - 1.3.6.1.4.1.232.3.2.5.1.1.70
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvTemperatureThreshold
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.71
|
|
type: gauge
|
|
help: Drive Array Physical Drive Temperature Threshold - 1.3.6.1.4.1.232.3.2.5.1.1.71
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvMaximumTemperature
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.72
|
|
type: gauge
|
|
help: Drive Array Physical Drive Maximum Temperature - 1.3.6.1.4.1.232.3.2.5.1.1.72
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSSDWearStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.73
|
|
type: gauge
|
|
help: Drive Array Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.3.2.5.1.1.73
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: fiftySixDayThreshold
|
|
4: fivePercentThreshold
|
|
5: twoPercentThreshold
|
|
6: ssdWearOut
|
|
- name: cpqDaPhyDrvPowerOnHours
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.74
|
|
type: counter
|
|
help: Drive Array Physical Drive Power On Hours - 1.3.6.1.4.1.232.3.2.5.1.1.74
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSSDPercntEndrnceUsed
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.75
|
|
type: gauge
|
|
help: Drive Array Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.3.2.5.1.1.75
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSSDEstTimeRemainingHours
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.76
|
|
type: counter
|
|
help: Drive Array Physical Drive Solid State Estimated Time Remaining In Hours
|
|
- 1.3.6.1.4.1.232.3.2.5.1.1.76
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvAuthenticationStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.77
|
|
type: gauge
|
|
help: Drive Array Physical Drive Authentication Status - 1.3.6.1.4.1.232.3.2.5.1.1.77
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: authenticationFailed
|
|
4: authenticationPassed
|
|
- name: cpqDaPhyDrvSmartCarrierAppFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.78
|
|
type: gauge
|
|
help: Physical Drive Smart Carrier Application Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.78
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSmartCarrierBootldrFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.79
|
|
type: gauge
|
|
help: Physical Drive Smart Carrier Bootloader Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.79
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvEncryptionStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.80
|
|
type: gauge
|
|
help: Physical Drive Encryption Status - 1.3.6.1.4.1.232.3.2.5.1.1.80
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: encrypted
|
|
3: notEncrypted
|
|
- name: cpqScsiMibRevMajor
|
|
oid: 1.3.6.1.4.1.232.5.1.1
|
|
type: gauge
|
|
help: The Major Revision level - 1.3.6.1.4.1.232.5.1.1
|
|
- name: cpqScsiMibRevMinor
|
|
oid: 1.3.6.1.4.1.232.5.1.2
|
|
type: gauge
|
|
help: The Minor Revision level - 1.3.6.1.4.1.232.5.1.2
|
|
- name: cpqScsiMibCondition
|
|
oid: 1.3.6.1.4.1.232.5.1.3
|
|
type: gauge
|
|
help: The overall condition - 1.3.6.1.4.1.232.5.1.3
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqScsiNw3xDriverName
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.1
|
|
type: DisplayString
|
|
help: SCSI Drive Device Driver Name - 1.3.6.1.4.1.232.5.2.1.1.1
|
|
- name: cpqScsiNw3xDriverVers
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.2
|
|
type: DisplayString
|
|
help: SCSI Drive Device Driver Version - 1.3.6.1.4.1.232.5.2.1.1.2
|
|
- name: cpqScsiNw3xDriverPollType
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.3
|
|
type: gauge
|
|
help: SCSI Drive Device Driver Poll Type - 1.3.6.1.4.1.232.5.2.1.1.3
|
|
enum_values:
|
|
1: other
|
|
2: polled
|
|
3: demand
|
|
- name: cpqScsiNw3xDriverPollTime
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.4
|
|
type: gauge
|
|
help: SCSI Drive Device Driver Poll Time - 1.3.6.1.4.1.232.5.2.1.1.4
|
|
- name: cpqScsiNw3xCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.1
|
|
type: gauge
|
|
help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.1.1.5.1.1
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.2
|
|
type: gauge
|
|
help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.5.1.2
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xXptDesc
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.3
|
|
type: DisplayString
|
|
help: SCSI XPT Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.3
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xXptVers
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.4
|
|
type: DisplayString
|
|
help: SCSI XPT Version - 1.3.6.1.4.1.232.5.2.1.1.5.1.4
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xSimDesc
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.5
|
|
type: DisplayString
|
|
help: SCSI SIM Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.5
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xSimVers
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.6
|
|
type: DisplayString
|
|
help: SCSI SIM Version - 1.3.6.1.4.1.232.5.2.1.1.5.1.6
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xHbaDesc
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.7
|
|
type: DisplayString
|
|
help: SCSI HBA Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.7
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xStatCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.1
|
|
type: gauge
|
|
help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.1
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xStatBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.2
|
|
type: gauge
|
|
help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.2
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xStatLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.3
|
|
type: gauge
|
|
help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.3
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xTotalReads
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.4
|
|
type: counter
|
|
help: SCSI Logical Drive Total Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.4
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xTotalWrites
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.5
|
|
type: counter
|
|
help: SCSI Logical Drive Total Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.5
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xCorrReads
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.6
|
|
type: counter
|
|
help: SCSI Logical Drive Corrected Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.6
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xCorrWrites
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.7
|
|
type: counter
|
|
help: SCSI Logical Drive Corrected Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.7
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xFatalReads
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.8
|
|
type: counter
|
|
help: SCSI Logical Drive Fatal Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.8
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xFatalWrites
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.9
|
|
type: counter
|
|
help: SCSI Logical Drive Fatal Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.9
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xVolCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.1
|
|
type: gauge
|
|
help: SCSI Cntlr Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.1
|
|
indexes:
|
|
- labelname: cpqScsiNw3xVolCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xVolBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.2
|
|
type: gauge
|
|
help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.2
|
|
indexes:
|
|
- labelname: cpqScsiNw3xVolCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xVolLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.3
|
|
type: gauge
|
|
help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.3
|
|
indexes:
|
|
- labelname: cpqScsiNw3xVolCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xVolMap
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.4
|
|
type: OctetString
|
|
help: SCSI Drive Volume Map - 1.3.6.1.4.1.232.5.2.1.1.7.1.4
|
|
indexes:
|
|
- labelname: cpqScsiNw3xVolCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonPollFreq
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.1
|
|
type: gauge
|
|
help: The agent`s polling frequency - 1.3.6.1.4.1.232.5.2.1.4.1
|
|
- name: cpqScsiOsCommonModuleIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.1
|
|
type: gauge
|
|
help: A unique index for this module description. - 1.3.6.1.4.1.232.5.2.1.4.2.1.1
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonModuleName
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.2
|
|
type: DisplayString
|
|
help: The module name. - 1.3.6.1.4.1.232.5.2.1.4.2.1.2
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonModuleVersion
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.3
|
|
type: DisplayString
|
|
help: The module version in XX.YY format - 1.3.6.1.4.1.232.5.2.1.4.2.1.3
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonModuleDate
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.4
|
|
type: OctetString
|
|
help: The module date - 1.3.6.1.4.1.232.5.2.1.4.2.1.4
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonModulePurpose
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.5
|
|
type: DisplayString
|
|
help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.5.2.1.4.2.1.5
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.1
|
|
type: gauge
|
|
help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.2
|
|
type: gauge
|
|
help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrModel
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.3
|
|
type: gauge
|
|
help: SCSI Controller Model - 1.3.6.1.4.1.232.5.2.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: cpqs710
|
|
3: cpqs94
|
|
4: cpqs810p
|
|
5: cpqs825e
|
|
6: cpqs825p
|
|
7: cpqs974p
|
|
8: cpqs875p
|
|
9: extended
|
|
10: cpqs895p
|
|
11: cpqs896p
|
|
12: cpqa789x
|
|
13: cpqs876t
|
|
14: hpu320
|
|
15: hpu320r
|
|
16: generic
|
|
17: hp1u320g2
|
|
18: hp1u320g1
|
|
19: hpSc11Xe
|
|
- name: cpqScsiCntlrFWVers
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.4
|
|
type: DisplayString
|
|
help: SCSI Controller Firmware Version - 1.3.6.1.4.1.232.5.2.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrSWVers
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.5
|
|
type: DisplayString
|
|
help: SCSI Controller Software Version - 1.3.6.1.4.1.232.5.2.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrSlot
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.6
|
|
type: gauge
|
|
help: SCSI Controller Slot - 1.3.6.1.4.1.232.5.2.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrStatus
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.7
|
|
type: gauge
|
|
help: SCSI Controller Status - 1.3.6.1.4.1.232.5.2.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
- name: cpqScsiCntlrHardResets
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.8
|
|
type: counter
|
|
help: SCSI Controller Hard Resets - 1.3.6.1.4.1.232.5.2.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrSoftResets
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.9
|
|
type: counter
|
|
help: SCSI Controller Soft Resets - 1.3.6.1.4.1.232.5.2.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrTimeouts
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.10
|
|
type: counter
|
|
help: SCSI Controller Time-outs - 1.3.6.1.4.1.232.5.2.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrBaseIOAddr
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.11
|
|
type: gauge
|
|
help: SCSI Controller Base I/O Address - 1.3.6.1.4.1.232.5.2.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrCondition
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.12
|
|
type: gauge
|
|
help: SCSI Controller Condition - 1.3.6.1.4.1.232.5.2.2.1.1.12
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqScsiCntlrSerialNum
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.13
|
|
type: DisplayString
|
|
help: SCSI Controller Serial Number - 1.3.6.1.4.1.232.5.2.2.1.1.13
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrBusWidth
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.14
|
|
type: gauge
|
|
help: SCSI Controller Data Bus Width - 1.3.6.1.4.1.232.5.2.2.1.1.14
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: narrow
|
|
3: wide16
|
|
- name: cpqScsiCntlrModelExtended
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.15
|
|
type: DisplayString
|
|
help: SCSI Controller Model Name - 1.3.6.1.4.1.232.5.2.2.1.1.15
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrHwLocation
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.16
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the SCSI controller - 1.3.6.1.4.1.232.5.2.2.1.1.16
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrPciLocation
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.17
|
|
type: DisplayString
|
|
help: A string designating the PCI device location for the controller, following
|
|
the format DDDD:BB:DD.F, where DDDD is the PCI domain number, BB is the PCI
|
|
bus number, DD is the PCI device number, and F is the PCI function number -
|
|
1.3.6.1.4.1.232.5.2.2.1.1.17
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.1
|
|
type: gauge
|
|
help: SCSI Logical Drive Controller Index - 1.3.6.1.4.1.232.5.2.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.2
|
|
type: gauge
|
|
help: SCSI Logical Drive Bus Index - 1.3.6.1.4.1.232.5.2.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.3
|
|
type: gauge
|
|
help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvFaultTol
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.4
|
|
type: gauge
|
|
help: SCSI Logical Drive Fault Tolerance - 1.3.6.1.4.1.232.5.2.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: none
|
|
3: mirroring
|
|
4: dataGuard
|
|
5: distribDataGuard
|
|
6: enhancedMirroring
|
|
- name: cpqScsiLogDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.5
|
|
type: gauge
|
|
help: SCSI Logical Drive Status - 1.3.6.1.4.1.232.5.2.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: unconfigured
|
|
5: recovering
|
|
6: readyForRebuild
|
|
7: rebuilding
|
|
8: wrongDrive
|
|
9: badConnect
|
|
10: degraded
|
|
11: disabled
|
|
- name: cpqScsiLogDrvSize
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.6
|
|
type: gauge
|
|
help: SCSI Logical Drive Size - 1.3.6.1.4.1.232.5.2.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvPhyDrvIDs
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.7
|
|
type: OctetString
|
|
help: SCSI Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.5.2.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.8
|
|
type: gauge
|
|
help: SCSI Logical Drive Condition - 1.3.6.1.4.1.232.5.2.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqScsiLogDrvStripeSize
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.9
|
|
type: gauge
|
|
help: Logical Drive Stripe Size - 1.3.6.1.4.1.232.5.2.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvAvailSpares
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.10
|
|
type: OctetString
|
|
help: SCSI Logical Drive Available Spares - 1.3.6.1.4.1.232.5.2.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvPercentRebuild
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.11
|
|
type: gauge
|
|
help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.5.2.3.1.1.11
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvOsName
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.12
|
|
type: DisplayString
|
|
help: Logical Drive OS Name - 1.3.6.1.4.1.232.5.2.3.1.1.12
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.1
|
|
type: gauge
|
|
help: SCSI Physical Drive Controller Index - 1.3.6.1.4.1.232.5.2.4.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.2
|
|
type: gauge
|
|
help: SCSI Physical Drive Bus Index - 1.3.6.1.4.1.232.5.2.4.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.3
|
|
type: gauge
|
|
help: SCSI Physical Drive Index - 1.3.6.1.4.1.232.5.2.4.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvModel
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.4
|
|
type: DisplayString
|
|
help: SCSI Physical Drive Model - 1.3.6.1.4.1.232.5.2.4.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvFWRev
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.5
|
|
type: DisplayString
|
|
help: SCSI Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.2.4.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvVendor
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.6
|
|
type: DisplayString
|
|
help: SCSI Physical Drive Vendor - 1.3.6.1.4.1.232.5.2.4.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvSize
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.7
|
|
type: gauge
|
|
help: SCSI Physical Drive Size in MB - 1.3.6.1.4.1.232.5.2.4.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvScsiID
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.8
|
|
type: gauge
|
|
help: SCSI Physical Drive SCSI ID - 1.3.6.1.4.1.232.5.2.4.1.1.8
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.9
|
|
type: gauge
|
|
help: SCSI Physical Drive Status - 1.3.6.1.4.1.232.5.2.4.1.1.9
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: notConfigured
|
|
5: badCable
|
|
6: missingWasOk
|
|
7: missingWasFailed
|
|
8: predictiveFailure
|
|
9: missingWasPredictiveFailure
|
|
10: offline
|
|
11: missingWasOffline
|
|
12: hardError
|
|
- name: cpqScsiPhyDrvServiceHours
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.10
|
|
type: counter
|
|
help: SCSI Physical Drive Service Time in hours - 1.3.6.1.4.1.232.5.2.4.1.1.10
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHighReadSectors
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.11
|
|
type: counter
|
|
help: SCSI Physical Drive Sectors Read (high) - 1.3.6.1.4.1.232.5.2.4.1.1.11
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvLowReadSectors
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.12
|
|
type: counter
|
|
help: SCSI Physical Drive Sectors Read (low) - 1.3.6.1.4.1.232.5.2.4.1.1.12
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHighWriteSectors
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.13
|
|
type: counter
|
|
help: SCSI Physical Drive Sectors Written (high) - 1.3.6.1.4.1.232.5.2.4.1.1.13
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvLowWriteSectors
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.14
|
|
type: counter
|
|
help: SCSI Physical Drive Sectors Written (low) - 1.3.6.1.4.1.232.5.2.4.1.1.14
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHardReadErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.15
|
|
type: counter
|
|
help: SCSI Physical Drive Hard Read Errors - 1.3.6.1.4.1.232.5.2.4.1.1.15
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHardWriteErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.16
|
|
type: counter
|
|
help: SCSI Physical Drive Hard Write Errors - 1.3.6.1.4.1.232.5.2.4.1.1.16
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvEccCorrReads
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.17
|
|
type: counter
|
|
help: SCSI Physical Drive ECC Corrected Read Errors (high) - 1.3.6.1.4.1.232.5.2.4.1.1.17
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvRecvReadErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.18
|
|
type: counter
|
|
help: SCSI Physical Drive Recovered Read Errors - 1.3.6.1.4.1.232.5.2.4.1.1.18
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvRecvWriteErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.19
|
|
type: counter
|
|
help: SCSI Physical Drive Recovered Write Errors - 1.3.6.1.4.1.232.5.2.4.1.1.19
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvSeekErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.20
|
|
type: counter
|
|
help: SCSI Physical Drive Seek Errors - 1.3.6.1.4.1.232.5.2.4.1.1.20
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvSpinupTime
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.21
|
|
type: gauge
|
|
help: SCSI Physical Drive Spin up Time (tenths of seconds) - 1.3.6.1.4.1.232.5.2.4.1.1.21
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvUsedReallocs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.22
|
|
type: counter
|
|
help: SCSI Physical Drive Used Reallocation Sectors - 1.3.6.1.4.1.232.5.2.4.1.1.22
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvTimeouts
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.23
|
|
type: counter
|
|
help: SCSI Physical Drive Time-out Errors - 1.3.6.1.4.1.232.5.2.4.1.1.23
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvPostErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.24
|
|
type: counter
|
|
help: SCSI Physical Drive Power On Self Test (POST) Errors - 1.3.6.1.4.1.232.5.2.4.1.1.24
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvPostErrCode
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.25
|
|
type: gauge
|
|
help: SCSI Physical Drive Last POST Error Code - 1.3.6.1.4.1.232.5.2.4.1.1.25
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.26
|
|
type: gauge
|
|
help: SCSI Physical Drive Condition - 1.3.6.1.4.1.232.5.2.4.1.1.26
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqScsiPhyDrvFuncTest1
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.27
|
|
type: gauge
|
|
help: SCSI Physical Drive Functional Test 1 - 1.3.6.1.4.1.232.5.2.4.1.1.27
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvFuncTest2
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.28
|
|
type: gauge
|
|
help: SCSI Physical Drive Functional Test 2 - 1.3.6.1.4.1.232.5.2.4.1.1.28
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvStatsPreserved
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.29
|
|
type: gauge
|
|
help: SCSI Physical Drive Statistics Preservation Method - 1.3.6.1.4.1.232.5.2.4.1.1.29
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: inNVRAM
|
|
3: onDisk
|
|
4: noCPUSupport
|
|
5: noFreeNVRAM
|
|
6: noDrvSupport
|
|
7: noSoftwareSupport
|
|
8: statsNotSupported
|
|
- name: cpqScsiPhyDrvSerialNum
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.30
|
|
type: DisplayString
|
|
help: SCSI Physical Drive Serial Number - 1.3.6.1.4.1.232.5.2.4.1.1.30
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvLocation
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.31
|
|
type: gauge
|
|
help: SCSI Physical Drive Location - 1.3.6.1.4.1.232.5.2.4.1.1.31
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: proliant
|
|
- name: cpqScsiPhyDrvParent
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.32
|
|
type: gauge
|
|
help: SCSI Physical Drive Parent - 1.3.6.1.4.1.232.5.2.4.1.1.32
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvSectorSize
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.33
|
|
type: gauge
|
|
help: SCSI Physical Drive Sector Size in Bytes - 1.3.6.1.4.1.232.5.2.4.1.1.33
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHotPlug
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.34
|
|
type: gauge
|
|
help: SCSI Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.2.4.1.1.34
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: hotPlug
|
|
3: nonHotPlug
|
|
- name: cpqScsiPhyDrvPlacement
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.35
|
|
type: gauge
|
|
help: SCSI Physical Drive Placement - 1.3.6.1.4.1.232.5.2.4.1.1.35
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
- name: cpqScsiPhyDrvPreFailMonitoring
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.36
|
|
type: gauge
|
|
help: SCSI Physical Drive Predictive Failure Monitoring - 1.3.6.1.4.1.232.5.2.4.1.1.36
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notAvailable
|
|
3: available
|
|
- name: cpqScsiPhyDrvOsName
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.37
|
|
type: DisplayString
|
|
help: Physical Drive OS Name - 1.3.6.1.4.1.232.5.2.4.1.1.37
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvRotationalSpeed
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.38
|
|
type: gauge
|
|
help: SCSI Physical Drive Rotational Speed - 1.3.6.1.4.1.232.5.2.4.1.1.38
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rpm7200
|
|
3: rpm10K
|
|
4: rpm15K
|
|
- name: cpqScsiPhyDrvMemberLogDrv
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.39
|
|
type: gauge
|
|
help: The Physical Drive is a Member of a Logical Drive - 1.3.6.1.4.1.232.5.2.4.1.1.39
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: member
|
|
3: spare
|
|
4: nonMember
|
|
- name: cpqScsiTargetCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.1
|
|
type: gauge
|
|
help: SCSI Target Controller Index - 1.3.6.1.4.1.232.5.2.5.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.2
|
|
type: gauge
|
|
help: SCSI Target Bus Index - 1.3.6.1.4.1.232.5.2.5.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.3
|
|
type: gauge
|
|
help: SCSI Target Device Index - 1.3.6.1.4.1.232.5.2.5.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetType
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.4
|
|
type: gauge
|
|
help: SCSI Device Type - 1.3.6.1.4.1.232.5.2.5.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: disk
|
|
3: tape
|
|
4: printer
|
|
5: processor
|
|
6: wormDrive
|
|
7: cd-rom
|
|
8: scanner
|
|
9: optical
|
|
10: jukeBox
|
|
11: commDev
|
|
- name: cpqScsiTargetModel
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.5
|
|
type: DisplayString
|
|
help: SCSI Device Model - 1.3.6.1.4.1.232.5.2.5.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetFWRev
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.6
|
|
type: DisplayString
|
|
help: SCSI Device Firmware Revision - 1.3.6.1.4.1.232.5.2.5.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetVendor
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.7
|
|
type: DisplayString
|
|
help: SCSI Device Vendor - 1.3.6.1.4.1.232.5.2.5.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetParityErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.8
|
|
type: counter
|
|
help: SCSI Device Bus Parity Errors - 1.3.6.1.4.1.232.5.2.5.1.1.8
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetPhaseErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.9
|
|
type: counter
|
|
help: SCSI Device Bus Phase Errors - 1.3.6.1.4.1.232.5.2.5.1.1.9
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetSelectTimeouts
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.10
|
|
type: counter
|
|
help: SCSI Device Bus Select Time-outs - 1.3.6.1.4.1.232.5.2.5.1.1.10
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetMsgRejects
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.11
|
|
type: counter
|
|
help: SCSI Device Bus Message Rejects - 1.3.6.1.4.1.232.5.2.5.1.1.11
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetNegPeriod
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.12
|
|
type: gauge
|
|
help: SCSI Device Negotiated Period - 1.3.6.1.4.1.232.5.2.5.1.1.12
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetLocation
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.13
|
|
type: gauge
|
|
help: SCSI Device Location - 1.3.6.1.4.1.232.5.2.5.1.1.13
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: proliant
|
|
- name: cpqScsiTargetNegSpeed
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.14
|
|
type: gauge
|
|
help: SCSI Device Negotiated Speed - 1.3.6.1.4.1.232.5.2.5.1.1.14
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetPhysWidth
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.15
|
|
type: gauge
|
|
help: SCSI Device Data Bus Physical Width - 1.3.6.1.4.1.232.5.2.5.1.1.15
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: narrow
|
|
3: wide16
|
|
- name: cpqScsiTargetNegWidth
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.16
|
|
type: gauge
|
|
help: SCSI Device Data Bus Negotiated Width - 1.3.6.1.4.1.232.5.2.5.1.1.16
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetTypeExtended
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.17
|
|
type: gauge
|
|
help: SCSI Extended Device Type - 1.3.6.1.4.1.232.5.2.5.1.1.17
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: pdcd
|
|
3: removableDisk
|
|
4: dltAutoloader
|
|
5: cdJukebox
|
|
6: cr3500
|
|
7: autoloader
|
|
- name: cpqScsiTargetCurrentSpeed
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.18
|
|
type: gauge
|
|
help: SCSI Device Current Data Transfer Speed - 1.3.6.1.4.1.232.5.2.5.1.1.18
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: asynchronous
|
|
3: fast
|
|
4: ultra
|
|
5: ultra2
|
|
6: ultra3
|
|
7: scsi1
|
|
8: ultra4
|
|
- name: cpqScsiCdDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.1
|
|
type: gauge
|
|
help: SCSI CD-ROM Drive Controller Index - 1.3.6.1.4.1.232.5.2.6.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.2
|
|
type: gauge
|
|
help: SCSI CD-ROM Drive Bus Index - 1.3.6.1.4.1.232.5.2.6.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.3
|
|
type: gauge
|
|
help: SCSI CD-ROM Drive Index - 1.3.6.1.4.1.232.5.2.6.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.4
|
|
type: gauge
|
|
help: SCSI CD-ROM Drive Logical Unit Index - 1.3.6.1.4.1.232.5.2.6.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvModel
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.5
|
|
type: DisplayString
|
|
help: SCSI CD Device Model - 1.3.6.1.4.1.232.5.2.6.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvVendor
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.6
|
|
type: DisplayString
|
|
help: SCSI CD Drive Vendor - 1.3.6.1.4.1.232.5.2.6.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvFwRev
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.7
|
|
type: DisplayString
|
|
help: SCSI CD-ROM Firmware Revision - 1.3.6.1.4.1.232.5.2.6.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.1
|
|
type: gauge
|
|
help: SCSI CD Library Controller Index - 1.3.6.1.4.1.232.5.2.6.2.1.1
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.2
|
|
type: gauge
|
|
help: SCSI CD Library Bus Index - 1.3.6.1.4.1.232.5.2.6.2.1.2
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.3
|
|
type: gauge
|
|
help: SCSI CD Library Device Index - 1.3.6.1.4.1.232.5.2.6.2.1.3
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.4
|
|
type: gauge
|
|
help: SCSI CD Library Logical Unit Index - 1.3.6.1.4.1.232.5.2.6.2.1.4
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryCondition
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.5
|
|
type: gauge
|
|
help: CD Library Condition - 1.3.6.1.4.1.232.5.2.6.2.1.5
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqCdLibraryStatus
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.6
|
|
type: gauge
|
|
help: CD Library Status - 1.3.6.1.4.1.232.5.2.6.2.1.6
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: offline
|
|
- name: cpqCdLibraryModel
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.7
|
|
type: DisplayString
|
|
help: SCSI CD Library Device Model - 1.3.6.1.4.1.232.5.2.6.2.1.7
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryVendor
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.8
|
|
type: DisplayString
|
|
help: SCSI CD Library Vendor - 1.3.6.1.4.1.232.5.2.6.2.1.8
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibrarySerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.9
|
|
type: DisplayString
|
|
help: CD Library Serial Number - 1.3.6.1.4.1.232.5.2.6.2.1.9
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryDriveList
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.10
|
|
type: OctetString
|
|
help: CD Library Drive List This is a data structure containing the list of CD
|
|
drive ids that are present in this library - 1.3.6.1.4.1.232.5.2.6.2.1.10
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryFwRev
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.11
|
|
type: DisplayString
|
|
help: SCSI CD Library Firmware Revision - 1.3.6.1.4.1.232.5.2.6.2.1.11
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryFwSubtype
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.12
|
|
type: gauge
|
|
help: SCSI CD library Firmware Subtype - 1.3.6.1.4.1.232.5.2.6.2.1.12
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqScsiTrapPkts
|
|
oid: 1.3.6.1.4.1.232.5.3.1
|
|
type: counter
|
|
help: The total number of trap packets issued by the SCSI enterprise since the
|
|
instrument agent was loaded. - 1.3.6.1.4.1.232.5.3.1
|
|
- name: cpqScsiTrapLogMaxSize
|
|
oid: 1.3.6.1.4.1.232.5.3.2
|
|
type: gauge
|
|
help: The maximum number of entries that will currently be kept in the trap log
|
|
- 1.3.6.1.4.1.232.5.3.2
|
|
- name: cpqScsiTrapLogIndex
|
|
oid: 1.3.6.1.4.1.232.5.3.3.1.1
|
|
type: gauge
|
|
help: The value of this object uniquely identifies this trapLogEntry at this time
|
|
- 1.3.6.1.4.1.232.5.3.3.1.1
|
|
indexes:
|
|
- labelname: cpqScsiTrapLogIndex
|
|
type: gauge
|
|
- name: cpqScsiTrapType
|
|
oid: 1.3.6.1.4.1.232.5.3.3.1.2
|
|
type: gauge
|
|
help: The type of the trap event that this entry describes - 1.3.6.1.4.1.232.5.3.3.1.2
|
|
indexes:
|
|
- labelname: cpqScsiTrapLogIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: cpqScsiCntlrStatusChange
|
|
2: cpqScsiLogDrvStatusChange
|
|
3: cpqScsiPhyDrvStatusChange
|
|
5001: cpqScsi2CntlrStatusChange
|
|
5002: cpqScsi2LogDrvStatusChange
|
|
5003: cpqScsi2PhyDrvStatusChange
|
|
- name: cpqScsiTrapTime
|
|
oid: 1.3.6.1.4.1.232.5.3.3.1.3
|
|
type: OctetString
|
|
help: The time of the trap event that this entry describes - 1.3.6.1.4.1.232.5.3.3.1.3
|
|
indexes:
|
|
- labelname: cpqScsiTrapLogIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.1
|
|
type: gauge
|
|
help: Tape Physical Drive Controller Index - 1.3.6.1.4.1.232.5.4.1.1.1.1
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.2
|
|
type: gauge
|
|
help: Tape Physical Drive Bus Index - 1.3.6.1.4.1.232.5.4.1.1.1.2
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.3
|
|
type: gauge
|
|
help: Tape Physical Drive Index - 1.3.6.1.4.1.232.5.4.1.1.1.3
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.4
|
|
type: gauge
|
|
help: Tape Physical Drive Logical Unit Index - 1.3.6.1.4.1.232.5.4.1.1.1.4
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvType
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.5
|
|
type: gauge
|
|
help: Tape Device Type - 1.3.6.1.4.1.232.5.4.1.1.1.5
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: cpqDat4-16
|
|
3: cpqDatAuto
|
|
4: cpqDat2-8
|
|
5: cpqDlt10-20
|
|
6: cpqDlt20-40
|
|
7: cpqDlt15-30
|
|
8: cpqDlt35-70
|
|
9: cpqDat4-8
|
|
10: cpqSlr4-8
|
|
11: cpqDat12-24
|
|
12: cpqDatAuto12-24
|
|
13: cpqMlr16-32
|
|
14: cpqAit35
|
|
15: cpqAit50
|
|
16: cpqDat20-40
|
|
17: cpqDlt40-80
|
|
18: cpqDatAuto20-40
|
|
19: cpqSuperDlt1
|
|
20: cpqAit35Lvd
|
|
21: cpqCompaq
|
|
- name: cpqTapePhyDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.6
|
|
type: gauge
|
|
help: Tape Physical Drive Status - 1.3.6.1.4.1.232.5.4.1.1.1.6
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqTapePhyDrvMagSize
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.7
|
|
type: gauge
|
|
help: Tape Physical Drive Magazine Size - 1.3.6.1.4.1.232.5.4.1.1.1.7
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.8
|
|
type: DisplayString
|
|
help: Tape Physical Drive Serial Number - 1.3.6.1.4.1.232.5.4.1.1.1.8
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvCleanReq
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.9
|
|
type: gauge
|
|
help: Tape Physical Drive Cleaning Required Status - 1.3.6.1.4.1.232.5.4.1.1.1.9
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqTapePhyDrvCleanTapeRepl
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.10
|
|
type: gauge
|
|
help: Tape Physical Drive Cleaning Tape Replacement Status - 1.3.6.1.4.1.232.5.4.1.1.1.10
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqTapePhyDrvFwSubtype
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.11
|
|
type: gauge
|
|
help: Tape Physical Drive Firmware Subtype - 1.3.6.1.4.1.232.5.4.1.1.1.11
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvName
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.12
|
|
type: DisplayString
|
|
help: Tape Physical Drive Name - 1.3.6.1.4.1.232.5.4.1.1.1.12
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvCleanTapeCount
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.13
|
|
type: gauge
|
|
help: Tape Physical Drive Cleaning Tape Count - 1.3.6.1.4.1.232.5.4.1.1.1.13
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvFwRev
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.14
|
|
type: DisplayString
|
|
help: Tape Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.4.1.1.1.14
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.15
|
|
type: gauge
|
|
help: Tape Physical Drive Status - 1.3.6.1.4.1.232.5.4.1.1.1.15
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
4: failed
|
|
5: offline
|
|
6: missingWasOk
|
|
7: missingWasFailed
|
|
8: missingWasOffline
|
|
- name: cpqTapePhyDrvHotPlug
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.16
|
|
type: gauge
|
|
help: Tape Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.4.1.1.1.16
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: hotPlug
|
|
3: nonHotPlug
|
|
- name: cpqTapePhyDrvPlacement
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.17
|
|
type: gauge
|
|
help: Tape Physical Drive Placement - 1.3.6.1.4.1.232.5.4.1.1.1.17
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
- name: cpqTapePhyDrvLibraryDrive
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.18
|
|
type: gauge
|
|
help: Tape Physical Drive Library Drive - 1.3.6.1.4.1.232.5.4.1.1.1.18
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqTapePhyDrvLoaderName
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.19
|
|
type: DisplayString
|
|
help: Tape Autoloader Name - 1.3.6.1.4.1.232.5.4.1.1.1.19
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvLoaderFwRev
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.20
|
|
type: DisplayString
|
|
help: Tape Autoloader Firmware Revision - 1.3.6.1.4.1.232.5.4.1.1.1.20
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvLoaderSerialNum
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.21
|
|
type: DisplayString
|
|
help: Tape Autoloader Serial Number - 1.3.6.1.4.1.232.5.4.1.1.1.21
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.1
|
|
type: gauge
|
|
help: SCSI Counters Controller Index - 1.3.6.1.4.1.232.5.4.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.2
|
|
type: gauge
|
|
help: SCSI Counters Bus Index - 1.3.6.1.4.1.232.5.4.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.3
|
|
type: gauge
|
|
help: SCSI Counters Device Index - 1.3.6.1.4.1.232.5.4.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.4
|
|
type: gauge
|
|
help: SCSI Counters Logical Unit Index - 1.3.6.1.4.1.232.5.4.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersReWrites
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.5
|
|
type: counter
|
|
help: Tape Device Re-write count - 1.3.6.1.4.1.232.5.4.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersReReads
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.6
|
|
type: counter
|
|
help: Tape Device Re-read count - 1.3.6.1.4.1.232.5.4.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersTotalErrors
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.7
|
|
type: counter
|
|
help: Tape Device Total Errors - 1.3.6.1.4.1.232.5.4.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersTotalUncorrectable
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.8
|
|
type: counter
|
|
help: Tape Device Total Uncorrectable Errors - 1.3.6.1.4.1.232.5.4.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersTotalBytes
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.9
|
|
type: counter
|
|
help: Tape Device Total Bytes - 1.3.6.1.4.1.232.5.4.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.1
|
|
type: gauge
|
|
help: SCSI Library Controller Index - 1.3.6.1.4.1.232.5.4.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.2
|
|
type: gauge
|
|
help: SCSI Library Bus Index - 1.3.6.1.4.1.232.5.4.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.3
|
|
type: gauge
|
|
help: SCSI Library Device Index - 1.3.6.1.4.1.232.5.4.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.4
|
|
type: gauge
|
|
help: SCSI Library Logical Unit Index - 1.3.6.1.4.1.232.5.4.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryCondition
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.5
|
|
type: gauge
|
|
help: Tape Library Status - 1.3.6.1.4.1.232.5.4.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqTapeLibraryStatus
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.6
|
|
type: gauge
|
|
help: Error code returned by the last library error. - 1.3.6.1.4.1.232.5.4.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryDoorStatus
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.7
|
|
type: gauge
|
|
help: Status of the library door - 1.3.6.1.4.1.232.5.4.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: closed
|
|
3: open
|
|
4: notSupported
|
|
- name: cpqTapeLibraryStatHours
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.8
|
|
type: counter
|
|
help: The number of hours of operation for the library. - 1.3.6.1.4.1.232.5.4.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryStatMoves
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.9
|
|
type: counter
|
|
help: The number of tape moves for the library loader arm. - 1.3.6.1.4.1.232.5.4.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryName
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.10
|
|
type: DisplayString
|
|
help: Tape Library Name. - 1.3.6.1.4.1.232.5.4.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibrarySerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.11
|
|
type: DisplayString
|
|
help: Tape Library Serial Number - 1.3.6.1.4.1.232.5.4.3.1.1.11
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryDriveList
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.12
|
|
type: OctetString
|
|
help: Tape Library Drive List This is a data structure containing the list of
|
|
tape drive ids that are present in this library - 1.3.6.1.4.1.232.5.4.3.1.1.12
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryState
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.13
|
|
type: gauge
|
|
help: Tape Library Status - 1.3.6.1.4.1.232.5.4.3.1.1.13
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
5: offline
|
|
- name: cpqTapeLibraryTemperature
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.14
|
|
type: gauge
|
|
help: Tape Library Temperature Status - 1.3.6.1.4.1.232.5.4.3.1.1.14
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: ok
|
|
4: safeTempExceeded
|
|
5: maxTempExceeded
|
|
- name: cpqTapeLibraryRedundancy
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.15
|
|
type: gauge
|
|
help: Tape Library Redundancy Status - 1.3.6.1.4.1.232.5.4.3.1.1.15
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: capable
|
|
4: notCapable
|
|
5: active
|
|
- name: cpqTapeLibraryHotSwap
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.16
|
|
type: gauge
|
|
help: Tape Library Hot Swap Status - 1.3.6.1.4.1.232.5.4.3.1.1.16
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: capable
|
|
4: notCapable
|
|
- name: cpqTapeLibraryFwRev
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.17
|
|
type: DisplayString
|
|
help: Tape Library Firmware Revision - 1.3.6.1.4.1.232.5.4.3.1.1.17
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryTapeList
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.18
|
|
type: OctetString
|
|
help: Tape Library Drive List This is a data structure containing the list of
|
|
tape drive ids that are present in this library - 1.3.6.1.4.1.232.5.4.3.1.1.18
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqSasHbaIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.1
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Index - 1.3.6.1.4.1.232.5.5.1.1.1.1
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaHwLocation
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.2
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter Hardware Location - 1.3.6.1.4.1.232.5.5.1.1.1.2
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaModel
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.3
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Model - 1.3.6.1.4.1.232.5.5.1.1.1.3
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: generic
|
|
3: sas8int
|
|
4: sas4int
|
|
5: sasSc44Ge
|
|
6: sasSc40Ge
|
|
7: sasSc08Ge
|
|
8: sasSc08e
|
|
9: sasH220i
|
|
10: sasH221
|
|
11: sasH210i
|
|
12: sasH220
|
|
13: sasH222
|
|
14: sasP824ip
|
|
- name: cpqSasHbaStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.4
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Status - 1.3.6.1.4.1.232.5.5.1.1.1.4
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
- name: cpqSasHbaCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.5
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Condition - 1.3.6.1.4.1.232.5.5.1.1.1.5
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasHbaOverallCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.6
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Overall Condition - 1.3.6.1.4.1.232.5.5.1.1.1.6
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasHbaSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.7
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter Serial Number - 1.3.6.1.4.1.232.5.5.1.1.1.7
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaFwVersion
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.8
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter Firmware Version - 1.3.6.1.4.1.232.5.5.1.1.1.8
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaBiosVersion
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.9
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter BIOS Version - 1.3.6.1.4.1.232.5.5.1.1.1.9
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaPciLocation
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.10
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter PCI Location - 1.3.6.1.4.1.232.5.5.1.1.1.10
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvHbaIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.1
|
|
type: gauge
|
|
help: SAS Physical Drive HBA Index - 1.3.6.1.4.1.232.5.5.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.2
|
|
type: gauge
|
|
help: SAS Physical Drive Index - 1.3.6.1.4.1.232.5.5.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvLocationString
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.3
|
|
type: DisplayString
|
|
help: SAS Physical Drive Location String - 1.3.6.1.4.1.232.5.5.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvModel
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.4
|
|
type: DisplayString
|
|
help: SAS Physical Drive Model - 1.3.6.1.4.1.232.5.5.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.5
|
|
type: gauge
|
|
help: SAS Physical Drive Status - 1.3.6.1.4.1.232.5.5.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: predictiveFailure
|
|
4: offline
|
|
5: failed
|
|
6: missingWasOk
|
|
7: missingWasPredictiveFailure
|
|
8: missingWasOffline
|
|
9: missingWasFailed
|
|
10: ssdWearOut
|
|
11: missingWasSSDWearOut
|
|
12: notAuthenticated
|
|
13: missingWasNotAuthenticated
|
|
- name: cpqSasPhyDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.6
|
|
type: gauge
|
|
help: SAS Physical Drive Condition - 1.3.6.1.4.1.232.5.5.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasPhyDrvFWRev
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.7
|
|
type: DisplayString
|
|
help: SAS Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSize
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.8
|
|
type: gauge
|
|
help: SAS Physical Drive Size in MB - 1.3.6.1.4.1.232.5.5.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvUsedReallocs
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.9
|
|
type: counter
|
|
help: SAS Physical Drive Used Reallocation Sectors - 1.3.6.1.4.1.232.5.5.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.10
|
|
type: DisplayString
|
|
help: SAS Physical Drive Serial Number - 1.3.6.1.4.1.232.5.5.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvMemberLogDrv
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.11
|
|
type: gauge
|
|
help: The Physical Drive is a Member of a Logical Drive - 1.3.6.1.4.1.232.5.5.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: member
|
|
3: spare
|
|
4: nonMember
|
|
- name: cpqSasPhyDrvRotationalSpeed
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.12
|
|
type: gauge
|
|
help: SAS Physical Drive Rotational Speed - 1.3.6.1.4.1.232.5.5.2.1.1.12
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rpm7200
|
|
3: rpm10K
|
|
4: rpm15K
|
|
5: rpmSsd
|
|
- name: cpqSasPhyDrvOsName
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.13
|
|
type: DisplayString
|
|
help: SAS Physical Drive OS Name - 1.3.6.1.4.1.232.5.5.2.1.1.13
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvPlacement
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.14
|
|
type: gauge
|
|
help: SAS Physical Drive Placement - 1.3.6.1.4.1.232.5.5.2.1.1.14
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
- name: cpqSasPhyDrvHotPlug
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.15
|
|
type: gauge
|
|
help: SAS Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.5.2.1.1.15
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: hotPlug
|
|
3: nonHotPlug
|
|
- name: cpqSasPhyDrvType
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.16
|
|
type: gauge
|
|
help: SAS Physical Drive Type - 1.3.6.1.4.1.232.5.5.2.1.1.16
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: sas
|
|
3: sata
|
|
- name: cpqSasPhyDrvSasAddress
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.17
|
|
type: DisplayString
|
|
help: SAS Physical Drive SAS Address - 1.3.6.1.4.1.232.5.5.2.1.1.17
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvMediaType
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.18
|
|
type: gauge
|
|
help: SAS Physical Drive Media Type - 1.3.6.1.4.1.232.5.5.2.1.1.18
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rotatingPlatters
|
|
3: solidState
|
|
- name: cpqSasPhyDrvSSDWearStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.19
|
|
type: gauge
|
|
help: SAS Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.5.5.2.1.1.19
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: fiftySixDayThreshold
|
|
4: fivePercentThreshold
|
|
5: twoPercentThreshold
|
|
6: ssdWearOut
|
|
- name: cpqSasPhyDrvPowerOnHours
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.20
|
|
type: counter
|
|
help: SAS Physical Drive Power On Hours - 1.3.6.1.4.1.232.5.5.2.1.1.20
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSSDPercntEndrnceUsed
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.21
|
|
type: gauge
|
|
help: SAS Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.5.5.2.1.1.21
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSSDEstTimeRemainingHours
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.22
|
|
type: counter
|
|
help: SAS Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.5.5.2.1.1.22
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvAuthenticationStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.23
|
|
type: gauge
|
|
help: SAS Physical Drive Authentication Status - 1.3.6.1.4.1.232.5.5.2.1.1.23
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: authenticationFailed
|
|
4: authenticationPassed
|
|
- name: cpqSasPhyDrvSmartCarrierAppFWRev
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.24
|
|
type: gauge
|
|
help: SAS Physical Drive Smart Carrier Application Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.24
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSmartCarrierBootldrFWRev
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.25
|
|
type: gauge
|
|
help: SAS Physical Drive Smart Carrier Bootloader Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.25
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvCurrTemperature
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.26
|
|
type: gauge
|
|
help: SAS Physical Drive Current Operating Temperature degrees Celsius - 1.3.6.1.4.1.232.5.5.2.1.1.26
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvTemperatureThreshold
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.27
|
|
type: gauge
|
|
help: SAS Physical Drive Maximum Operating Temperature in degrees Celsius - 1.3.6.1.4.1.232.5.5.2.1.1.27
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSsBoxModel
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.28
|
|
type: DisplayString
|
|
help: SAS Physical Drive Box Model - 1.3.6.1.4.1.232.5.5.2.1.1.28
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSsBoxFwRev
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.29
|
|
type: DisplayString
|
|
help: SAS Physical Drive Box Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.29
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSsBoxVendor
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.30
|
|
type: DisplayString
|
|
help: SAS Physical Drive Box Vendor This is the SAS drive box`s vendor name -
|
|
1.3.6.1.4.1.232.5.5.2.1.1.30
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSsBoxSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.31
|
|
type: DisplayString
|
|
help: SAS Physical Drive Box Serial Number - 1.3.6.1.4.1.232.5.5.2.1.1.31
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvHbaIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.1
|
|
type: gauge
|
|
help: SAS Logical Drive HBA Index - 1.3.6.1.4.1.232.5.5.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.2
|
|
type: gauge
|
|
help: SAS Logical Drive Index - 1.3.6.1.4.1.232.5.5.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvRaidLevel
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.3
|
|
type: gauge
|
|
help: SAS Logical Drive RAID Level - 1.3.6.1.4.1.232.5.5.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: raid0
|
|
3: raid1
|
|
4: raid0plus1
|
|
5: raid5
|
|
6: raid15
|
|
7: volume
|
|
- name: cpqSasLogDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.4
|
|
type: gauge
|
|
help: SAS Logical Drive Status - 1.3.6.1.4.1.232.5.5.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: rebuilding
|
|
5: failed
|
|
6: offline
|
|
- name: cpqSasLogDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.5
|
|
type: gauge
|
|
help: SAS Logical Drive Condition - 1.3.6.1.4.1.232.5.5.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasLogDrvRebuildingDisk
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.6
|
|
type: gauge
|
|
help: SAS Logical Drive Rebuilding Disk - 1.3.6.1.4.1.232.5.5.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvCapacity
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.7
|
|
type: gauge
|
|
help: SAS Logical Drive Size - 1.3.6.1.4.1.232.5.5.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvStripeSize
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.8
|
|
type: gauge
|
|
help: SAS Logical Drive Stripe Size - 1.3.6.1.4.1.232.5.5.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvPhyDrvIds
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.9
|
|
type: OctetString
|
|
help: SAS Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.5.5.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvSpareIds
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.10
|
|
type: OctetString
|
|
help: SAS Logical Drive Spare Drive IDs - 1.3.6.1.4.1.232.5.5.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvOsName
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.11
|
|
type: DisplayString
|
|
help: SAS Logical Drive OS Name - 1.3.6.1.4.1.232.5.5.3.1.1.11
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvRebuildingPercent
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.12
|
|
type: gauge
|
|
help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.5.5.3.1.1.12
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvHbaIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.1
|
|
type: gauge
|
|
help: SAS Tape Drive HBA Index - 1.3.6.1.4.1.232.5.5.4.1.1.1
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.2
|
|
type: gauge
|
|
help: SAS Tape Drive Index - 1.3.6.1.4.1.232.5.5.4.1.1.2
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvLocationString
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.3
|
|
type: DisplayString
|
|
help: SAS Tape Drive Location String - 1.3.6.1.4.1.232.5.5.4.1.1.3
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvName
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.4
|
|
type: DisplayString
|
|
help: SAS Tape Drive Name - 1.3.6.1.4.1.232.5.5.4.1.1.4
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.5
|
|
type: gauge
|
|
help: SAS Physical Drive Status - 1.3.6.1.4.1.232.5.5.4.1.1.5
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: offline
|
|
- name: cpqSasTapeDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.6
|
|
type: gauge
|
|
help: SAS Tape Drive Condition - 1.3.6.1.4.1.232.5.5.4.1.1.6
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasTapeDrvFWRev
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.7
|
|
type: DisplayString
|
|
help: SAS Tape Drive Firmware Revision - 1.3.6.1.4.1.232.5.5.4.1.1.7
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.8
|
|
type: DisplayString
|
|
help: SAS Tape Drive Serial Number - 1.3.6.1.4.1.232.5.5.4.1.1.8
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvSasAddress
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.9
|
|
type: DisplayString
|
|
help: SAS Tape Drive SAS Address - 1.3.6.1.4.1.232.5.5.4.1.1.9
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqHeResMem2ModuleSize
|
|
oid: 1.3.6.1.4.1.232.6.2.14.13.1.6
|
|
type: gauge
|
|
help: Module memory size in kilobytes - 1.3.6.1.4.1.232.6.2.14.13.1.6
|
|
indexes:
|
|
- labelname: cpqHeResMem2Module
|
|
type: gauge
|
|
- name: cpqHePowerMeterSupport
|
|
oid: 1.3.6.1.4.1.232.6.2.15.1
|
|
type: gauge
|
|
help: This value specifies whether Power Meter is supported by this Server -
|
|
1.3.6.1.4.1.232.6.2.15.1
|
|
enum_values:
|
|
1: other
|
|
2: supported
|
|
3: unsupported
|
|
- name: cpqHePowerMeterStatus
|
|
oid: 1.3.6.1.4.1.232.6.2.15.2
|
|
type: gauge
|
|
help: This value specifies whether Power Meter reading is supported by this Server -
|
|
1.3.6.1.4.1.232.6.2.15.2
|
|
enum_values:
|
|
1: other
|
|
2: present
|
|
3: absent
|
|
- name: cpqHePowerMeterCurrReading
|
|
oid: 1.3.6.1.4.1.232.6.2.15.3
|
|
type: gauge
|
|
help: This is the current Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.3
|
|
- name: cpqHePowerMeterPrevReading
|
|
oid: 1.3.6.1.4.1.232.6.2.15.4
|
|
type: gauge
|
|
help: This is the previous Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.4
|
|
- name: cpqHeHWBiosCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.16.1
|
|
type: gauge
|
|
help: This value indicates an error has been detected during Pre-OS Test (POST)
|
|
or during initial hardware initialization - 1.3.6.1.4.1.232.6.2.16.1
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeSysBackupBatteryCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.17.1
|
|
type: gauge
|
|
help: This value specifies the overall condition of the battery backup sub-system.
|
|
- 1.3.6.1.4.1.232.6.2.17.1
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeSysBatteryChassis
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.1
|
|
type: gauge
|
|
help: The system chassis number. - 1.3.6.1.4.1.232.6.2.17.2.1.1
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryIndex
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.2
|
|
type: gauge
|
|
help: The battery index number within this chassis. - 1.3.6.1.4.1.232.6.2.17.2.1.2
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryPresent
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.3
|
|
type: gauge
|
|
help: Indicates whether the backup battery is present in the chassis. - 1.3.6.1.4.1.232.6.2.17.2.1.3
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: absent
|
|
3: present
|
|
- name: cpqHeSysBatteryCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.4
|
|
type: gauge
|
|
help: The condition of the backup battery - 1.3.6.1.4.1.232.6.2.17.2.1.4
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeSysBatteryStatus
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.5
|
|
type: gauge
|
|
help: The status of the battery. - 1.3.6.1.4.1.232.6.2.17.2.1.5
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: noError
|
|
2: generalFailure
|
|
3: shutdownHighResistance
|
|
4: shutdownLowVoltage
|
|
5: shutdownShortCircuit
|
|
6: shutdownChargeTimeout
|
|
7: shutdownOverTemperature
|
|
8: shutdownDischargeMinVoltage
|
|
9: shutdownDischargeCurrent
|
|
10: shutdownLoadCountHigh
|
|
11: shutdownEnablePin
|
|
12: shutdownOverCurrent
|
|
13: shutdownPermanentFailure
|
|
14: shutdownBackupTimeExceeded
|
|
15: predictiveFailure
|
|
- name: cpqHeSysBatteryCapacityMaximum
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.6
|
|
type: gauge
|
|
help: The maximum capacity of the battery in watts. - 1.3.6.1.4.1.232.6.2.17.2.1.6
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryProductName
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.7
|
|
type: DisplayString
|
|
help: The battery product name. - 1.3.6.1.4.1.232.6.2.17.2.1.7
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryModel
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.8
|
|
type: DisplayString
|
|
help: The battery model name. - 1.3.6.1.4.1.232.6.2.17.2.1.8
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatterySerialNumber
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.9
|
|
type: DisplayString
|
|
help: The battery serial number. - 1.3.6.1.4.1.232.6.2.17.2.1.9
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryFirmwareRev
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.10
|
|
type: DisplayString
|
|
help: The battery firmware revision - 1.3.6.1.4.1.232.6.2.17.2.1.10
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatterySparePartNum
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.11
|
|
type: DisplayString
|
|
help: The battery part number or spare part number. - 1.3.6.1.4.1.232.6.2.17.2.1.11
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureChassis
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.1
|
|
type: gauge
|
|
help: The System Chassis number. - 1.3.6.1.4.1.232.6.2.6.8.1.1
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureIndex
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.2
|
|
type: gauge
|
|
help: A number that uniquely specifies this temperature sensor description. -
|
|
1.3.6.1.4.1.232.6.2.6.8.1.2
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureLocale
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.3
|
|
type: EnumAsInfo
|
|
help: This specifies the location of the temperature sensor present in the system.
|
|
- 1.3.6.1.4.1.232.6.2.6.8.1.3
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: system
|
|
4: systemBoard
|
|
5: ioBoard
|
|
6: cpu
|
|
7: memory
|
|
8: storage
|
|
9: removableMedia
|
|
10: powerSupply
|
|
11: ambient
|
|
12: chassis
|
|
13: bridgeCard
|
|
- name: cpqHeTemperatureCelsius
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.4
|
|
type: gauge
|
|
help: This is the current temperature sensor reading in degrees celsius - 1.3.6.1.4.1.232.6.2.6.8.1.4
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureThreshold
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.5
|
|
type: gauge
|
|
help: This is the shutdown threshold temperature sensor setting in degrees celsius
|
|
- 1.3.6.1.4.1.232.6.2.6.8.1.5
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.6
|
|
type: gauge
|
|
help: The Temperature sensor condition - 1.3.6.1.4.1.232.6.2.6.8.1.6
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeTemperatureThresholdType
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.7
|
|
type: gauge
|
|
help: This specifies the type of this instance of temperature sensor - 1.3.6.1.4.1.232.6.2.6.8.1.7
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
5: blowout
|
|
9: caution
|
|
15: critical
|
|
16: noreaction
|
|
- name: cpqHeTemperatureHwLocation
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.8
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the temperature sensor - 1.3.6.1.4.1.232.6.2.6.8.1.8
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeFltTolPwrSupplyCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.9.1
|
|
type: gauge
|
|
help: This value specifies the overall condition of the fault tolerant power supply
|
|
sub-system. - 1.3.6.1.4.1.232.6.2.9.1
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeFltTolPwrSupplyStatus
|
|
oid: 1.3.6.1.4.1.232.6.2.9.2
|
|
type: gauge
|
|
help: This value specifies the status of the fault tolerant power supply. - 1.3.6.1.4.1.232.6.2.9.2
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notInstalled
|
|
4: installed
|
|
- name: cpqHeFltTolPowerSupplyChassis
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.1
|
|
type: gauge
|
|
help: The system chassis number. - 1.3.6.1.4.1.232.6.2.9.3.1.1
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyBay
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.2
|
|
type: gauge
|
|
help: The bay number to index within this chassis. - 1.3.6.1.4.1.232.6.2.9.3.1.2
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyPresent
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.3
|
|
type: gauge
|
|
help: Indicates whether the power supply is present in the chassis. - 1.3.6.1.4.1.232.6.2.9.3.1.3
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: absent
|
|
3: present
|
|
- name: cpqHeFltTolPowerSupplyCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.4
|
|
type: gauge
|
|
help: The condition of the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.4
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeFltTolPowerSupplyStatus
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.5
|
|
type: gauge
|
|
help: The status of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.5
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: noError
|
|
2: generalFailure
|
|
3: bistFailure
|
|
4: fanFailure
|
|
5: tempFailure
|
|
6: interlockOpen
|
|
7: epromFailed
|
|
8: vrefFailed
|
|
9: dacFailed
|
|
10: ramTestFailed
|
|
11: voltageChannelFailed
|
|
12: orringdiodeFailed
|
|
13: brownOut
|
|
14: giveupOnStartup
|
|
15: nvramInvalid
|
|
16: calibrationTableInvalid
|
|
17: noPowerInput
|
|
- name: cpqHeFltTolPowerSupplyMainVoltage
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.6
|
|
type: gauge
|
|
help: The input main voltage of the power supply in volts. - 1.3.6.1.4.1.232.6.2.9.3.1.6
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyCapacityUsed
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.7
|
|
type: gauge
|
|
help: The currently used capacity of the power supply in watts. - 1.3.6.1.4.1.232.6.2.9.3.1.7
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyCapacityMaximum
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.8
|
|
type: gauge
|
|
help: The maximum capacity of the power supply in watts. - 1.3.6.1.4.1.232.6.2.9.3.1.8
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyRedundant
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.9
|
|
type: gauge
|
|
help: The redundancy state of the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.9
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notRedundant
|
|
3: redundant
|
|
- name: cpqHeFltTolPowerSupplyModel
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.10
|
|
type: DisplayString
|
|
help: The power supply model name. - 1.3.6.1.4.1.232.6.2.9.3.1.10
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplySerialNumber
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.11
|
|
type: DisplayString
|
|
help: The power supply serial number. - 1.3.6.1.4.1.232.6.2.9.3.1.11
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyAutoRev
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.12
|
|
type: OctetString
|
|
help: The power supply auto revision number. - 1.3.6.1.4.1.232.6.2.9.3.1.12
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyHotPlug
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.13
|
|
type: gauge
|
|
help: This indicates if the power supply is capable of being removed and/or inserted
|
|
while the system is in an operational state - 1.3.6.1.4.1.232.6.2.9.3.1.13
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: nonHotPluggable
|
|
3: hotPluggable
|
|
- name: cpqHeFltTolPowerSupplyFirmwareRev
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.14
|
|
type: DisplayString
|
|
help: The power supply firmware revision - 1.3.6.1.4.1.232.6.2.9.3.1.14
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyHwLocation
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.15
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.15
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplySparePartNum
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.16
|
|
type: DisplayString
|
|
help: The power supply part number or spare part number. - 1.3.6.1.4.1.232.6.2.9.3.1.16
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyRedundantPartner
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.17
|
|
type: gauge
|
|
help: This specifies the index of the redundant partner - 1.3.6.1.4.1.232.6.2.9.3.1.17
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyErrorCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.18
|
|
type: gauge
|
|
help: The Error condition of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.18
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: noError
|
|
2: generalFailure
|
|
3: overvoltage
|
|
4: overcurrent
|
|
5: overtemperature
|
|
6: powerinputloss
|
|
7: fanfailure
|
|
8: vinhighwarning
|
|
9: vinlowwarning
|
|
10: vouthighwarning
|
|
11: voutlowwarning
|
|
12: inlettemphighwarning
|
|
13: iinternaltemphighwarning
|
|
14: vauxhighwarning
|
|
15: vauxlowwarning
|
|
16: powersupplymismatch
|
|
17: goodinstandby
|
|
- name: cpqSm2CntlrRomDate
|
|
oid: 1.3.6.1.4.1.232.9.2.2.1
|
|
type: DisplayString
|
|
help: Remote Insight/ Integrated Lights-Out ROM Date - 1.3.6.1.4.1.232.9.2.2.1
|
|
- name: cpqSm2CntlrRomRevision
|
|
oid: 1.3.6.1.4.1.232.9.2.2.2
|
|
type: DisplayString
|
|
help: Remote Insight/ Integrated Lights-Out ROM Revision - 1.3.6.1.4.1.232.9.2.2.2
|
|
- name: cpqSm2CntlrVideoStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.3
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Video Hardware Status - 1.3.6.1.4.1.232.9.2.2.3
|
|
enum_values:
|
|
1: other
|
|
2: enabled
|
|
3: disabled
|
|
- name: cpqSm2CntlrBatteryEnabled
|
|
oid: 1.3.6.1.4.1.232.9.2.2.4
|
|
type: gauge
|
|
help: Remote Insight Battery Enabled - 1.3.6.1.4.1.232.9.2.2.4
|
|
enum_values:
|
|
1: other
|
|
2: enabled
|
|
3: disabled
|
|
4: noBattery
|
|
- name: cpqSm2CntlrBatteryStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.5
|
|
type: gauge
|
|
help: Remote Insight Battery Status - 1.3.6.1.4.1.232.9.2.2.5
|
|
enum_values:
|
|
1: other
|
|
2: batteryOk
|
|
3: batteryFailed
|
|
4: batteryDisconnected
|
|
- name: cpqSm2CntlrBatteryPercentCharged
|
|
oid: 1.3.6.1.4.1.232.9.2.2.6
|
|
type: gauge
|
|
help: Remote Insight Battery Percent Charged - 1.3.6.1.4.1.232.9.2.2.6
|
|
- name: cpqSm2CntlrAlertStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.7
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Alerting Status - 1.3.6.1.4.1.232.9.2.2.7
|
|
enum_values:
|
|
1: other
|
|
2: enabled
|
|
3: disabled
|
|
- name: cpqSm2CntlrPendingAlerts
|
|
oid: 1.3.6.1.4.1.232.9.2.2.8
|
|
type: gauge
|
|
help: Pending Remote Insight/ Integrated Lights-Out alerts - 1.3.6.1.4.1.232.9.2.2.8
|
|
enum_values:
|
|
1: other
|
|
2: noAlertsPending
|
|
3: alertsPending
|
|
4: clearPendingAlerts
|
|
- name: cpqSm2CntlrSelfTestErrors
|
|
oid: 1.3.6.1.4.1.232.9.2.2.9
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Self Test Errors - 1.3.6.1.4.1.232.9.2.2.9
|
|
- name: cpqSm2CntlrAgentLocation
|
|
oid: 1.3.6.1.4.1.232.9.2.2.10
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Agent Location - 1.3.6.1.4.1.232.9.2.2.10
|
|
enum_values:
|
|
1: hostOsAgent
|
|
2: firmwareAgent
|
|
3: remoteInsightPciFirmwareAgent
|
|
4: enclosureFirmwareAgent
|
|
- name: cpqSm2CntlrLastDataUpdate
|
|
oid: 1.3.6.1.4.1.232.9.2.2.11
|
|
type: OctetString
|
|
help: The date and time that the Remote Insight/ Integrated Lights-Out offline
|
|
data was last updated - 1.3.6.1.4.1.232.9.2.2.11
|
|
- name: cpqSm2CntlrDataStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.12
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Host OS Data Status - 1.3.6.1.4.1.232.9.2.2.12
|
|
enum_values:
|
|
1: other
|
|
2: noData
|
|
3: onlineData
|
|
4: offlineData
|
|
- name: cpqSm2CntlrColdReboot
|
|
oid: 1.3.6.1.4.1.232.9.2.2.13
|
|
type: gauge
|
|
help: 'Remote Insight/ Integrated Lights-Out Server Cold Reboot The following
|
|
values are defined: notAvailable(1) Cold reboot of the system is not available
|
|
- 1.3.6.1.4.1.232.9.2.2.13'
|
|
enum_values:
|
|
1: notAvailable
|
|
2: available
|
|
3: doColdReboot
|
|
- name: cpqSm2CntlrBadLoginAttemptsThresh
|
|
oid: 1.3.6.1.4.1.232.9.2.2.14
|
|
type: gauge
|
|
help: Maximum Unauthorized Login Attempts Threshold - 1.3.6.1.4.1.232.9.2.2.14
|
|
- name: cpqSm2CntlrBoardSerialNumber
|
|
oid: 1.3.6.1.4.1.232.9.2.2.15
|
|
type: DisplayString
|
|
help: Remote Insight/ Integrated Lights-Out Serial Number - 1.3.6.1.4.1.232.9.2.2.15
|
|
- name: cpqSm2CntlrRemoteSessionStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.16
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Session Status - 1.3.6.1.4.1.232.9.2.2.16
|
|
enum_values:
|
|
1: other
|
|
2: active
|
|
3: inactive
|
|
- name: cpqSm2CntlrInterfaceStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.17
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Interface Status - 1.3.6.1.4.1.232.9.2.2.17
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: notResponding
|
|
- name: cpqSm2CntlrSystemId
|
|
oid: 1.3.6.1.4.1.232.9.2.2.18
|
|
type: DisplayString
|
|
help: Remote Insight/ Integrated Lights-Out System ID - 1.3.6.1.4.1.232.9.2.2.18
|
|
- name: cpqSm2CntlrKeyboardCableStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.19
|
|
type: gauge
|
|
help: Remote Insight Keyboard Cable Status - 1.3.6.1.4.1.232.9.2.2.19
|
|
enum_values:
|
|
1: other
|
|
2: connected
|
|
3: disconnected
|
|
- name: cpqSm2ServerIpAddress
|
|
oid: 1.3.6.1.4.1.232.9.2.2.20
|
|
type: InetAddressIPv4
|
|
help: The IP address for this servers connection to the Remote Insight/ Integrated
|
|
Lights-Out - 1.3.6.1.4.1.232.9.2.2.20
|
|
- name: cpqSm2CntlrModel
|
|
oid: 1.3.6.1.4.1.232.9.2.2.21
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Model - 1.3.6.1.4.1.232.9.2.2.21
|
|
enum_values:
|
|
1: other
|
|
2: eisaRemoteInsightBoard
|
|
3: pciRemoteInsightBoard
|
|
4: pciLightsOutRemoteInsightBoard
|
|
5: pciIntegratedLightsOutRemoteInsight
|
|
6: pciLightsOutRemoteInsightBoardII
|
|
7: pciIntegratedLightsOutRemoteInsight2
|
|
8: pciLightsOut100series
|
|
9: pciIntegratedLightsOutRemoteInsight3
|
|
10: pciIntegratedLightsOutRemoteInsight4
|
|
11: pciIntegratedLightsOutRemoteInsight5
|
|
- name: cpqSm2CntlrSelfTestErrorMask
|
|
oid: 1.3.6.1.4.1.232.9.2.2.22
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Self Test Error Mask - 1.3.6.1.4.1.232.9.2.2.22
|
|
- name: cpqSm2CntlrMouseCableStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.23
|
|
type: gauge
|
|
help: Remote Insight Mouse Cable Status - 1.3.6.1.4.1.232.9.2.2.23
|
|
enum_values:
|
|
1: other
|
|
2: connected
|
|
3: disconnected
|
|
- name: cpqSm2CntlrVirtualPowerCableStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.24
|
|
type: gauge
|
|
help: Remote Insight Virtual Power Cable Status - 1.3.6.1.4.1.232.9.2.2.24
|
|
enum_values:
|
|
1: other
|
|
2: connected
|
|
3: disconnected
|
|
4: notApplicable
|
|
- name: cpqSm2CntlrExternalPowerCableStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.25
|
|
type: gauge
|
|
help: Remote Insight External Power Cable Status - 1.3.6.1.4.1.232.9.2.2.25
|
|
enum_values:
|
|
1: other
|
|
2: externallyConnected
|
|
3: disconnected
|
|
4: internallyConnected
|
|
5: externallyAndInternallyConnected
|
|
6: notApplicable
|
|
- name: cpqSm2CntlrHostGUID
|
|
oid: 1.3.6.1.4.1.232.9.2.2.26
|
|
type: OctetString
|
|
help: The globally unique identifier of this server - 1.3.6.1.4.1.232.9.2.2.26
|
|
- name: cpqSm2CntlriLOSecurityOverrideSwitchState
|
|
oid: 1.3.6.1.4.1.232.9.2.2.27
|
|
type: gauge
|
|
help: Integrated Lights-Out Security Override Switch State - 1.3.6.1.4.1.232.9.2.2.27
|
|
enum_values:
|
|
1: notSupported
|
|
2: set
|
|
3: notSet
|
|
- name: cpqSm2CntlrHardwareVer
|
|
oid: 1.3.6.1.4.1.232.9.2.2.28
|
|
type: gauge
|
|
help: Hardware Version of Remote Insight/ Integrated Lights-Out. - 1.3.6.1.4.1.232.9.2.2.28
|
|
- name: cpqSm2CntlrAction
|
|
oid: 1.3.6.1.4.1.232.9.2.2.29
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Action Flags - 1.3.6.1.4.1.232.9.2.2.29
|
|
- name: cpqSm2CntlrLicenseActive
|
|
oid: 1.3.6.1.4.1.232.9.2.2.30
|
|
type: gauge
|
|
help: Remote Insight License State - 1.3.6.1.4.1.232.9.2.2.30
|
|
enum_values:
|
|
1: none
|
|
2: iloAdvanced
|
|
3: iloLight
|
|
4: iloAdvancedBlade
|
|
5: iloStandard
|
|
6: iloEssentials
|
|
7: iloScaleOut
|
|
8: iloAdvancedPremiumSecurity
|
|
- name: cpqSm2CntlrLicenseKey
|
|
oid: 1.3.6.1.4.1.232.9.2.2.31
|
|
type: DisplayString
|
|
help: iLO Active ASCII License key string - 1.3.6.1.4.1.232.9.2.2.31
|
|
- name: cpqSm2CntlrServerPowerState
|
|
oid: 1.3.6.1.4.1.232.9.2.2.32
|
|
type: gauge
|
|
help: The current power state for the server - 1.3.6.1.4.1.232.9.2.2.32
|
|
enum_values:
|
|
1: unknown
|
|
2: poweredOff
|
|
3: poweredOn
|
|
4: insufficientPowerOrPowerOnDenied
|
|
- name: cpqSm2CntlrSysAutoShutdownCause
|
|
oid: 1.3.6.1.4.1.232.9.2.2.33
|
|
type: gauge
|
|
help: Indicate the reason for triggering system auto shutdown or cancelling auto
|
|
shutdown. - 1.3.6.1.4.1.232.9.2.2.33
|
|
enum_values:
|
|
1: fanFailure
|
|
2: overheatCondition
|
|
3: vrmFailure
|
|
4: powerSupplyFailure
|
|
5: systemRunningOnBatteryBackupUnit
|
|
129: aborted
|
|
130: fanFailureAborted
|
|
131: overheatAborted
|
|
132: vrmFailureAborted
|
|
133: softPowerDown
|
|
134: softwareAutomaticServerRecovery
|
|
135: powerSupplyFailureAborted
|
|
- name: cpqSm2CntlrSecurityState
|
|
oid: 1.3.6.1.4.1.232.9.2.2.34
|
|
type: gauge
|
|
help: Indicate security state - 1.3.6.1.4.1.232.9.2.2.34
|
|
enum_values:
|
|
1: factory
|
|
2: wipe
|
|
3: production
|
|
4: highSecurity
|
|
5: fips
|
|
6: cnsa
|
|
- name: cpqSm2WDTimerType
|
|
oid: 1.3.6.1.4.1.232.9.2.2.35
|
|
type: gauge
|
|
help: Indicate the watchdog timer type. - 1.3.6.1.4.1.232.9.2.2.35
|
|
enum_values:
|
|
1: unknown
|
|
2: ipmi
|
|
- name: cpqSm2WDTimerTimeoutDetails
|
|
oid: 1.3.6.1.4.1.232.9.2.2.36
|
|
type: DisplayString
|
|
help: Indicate the watchdog timer timeout action and timer details. - 1.3.6.1.4.1.232.9.2.2.36
|
|
- name: cpqSm2CntlrOverallSecStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.37
|
|
type: gauge
|
|
help: The field indicates the overall security status. - 1.3.6.1.4.1.232.9.2.2.37
|
|
enum_values:
|
|
1: Ok
|
|
2: Risk
|
|
3: Ignored
|
|
version: 2
|
|
auth:
|
|
community: hp_dl380_g10
|
|
hpe_walk:
|
|
walk:
|
|
- 1.3.6.1.4.1.232.1.2.2.1.1
|
|
- 1.3.6.1.4.1.232.11
|
|
- 1.3.6.1.4.1.232.14
|
|
- 1.3.6.1.4.1.232.3.2.2.1
|
|
- 1.3.6.1.4.1.232.3.2.3.1.1
|
|
- 1.3.6.1.4.1.232.3.2.5.1.1
|
|
- 1.3.6.1.4.1.232.5
|
|
- 1.3.6.1.4.1.232.6.2.14.13.1.6
|
|
- 1.3.6.1.4.1.232.6.2.15
|
|
- 1.3.6.1.4.1.232.6.2.16
|
|
- 1.3.6.1.4.1.232.6.2.17
|
|
- 1.3.6.1.4.1.232.6.2.6.8.1
|
|
- 1.3.6.1.4.1.232.6.2.9
|
|
- 1.3.6.1.4.1.232.9.2.2
|
|
get:
|
|
- 1.3.6.1.2.1.1.3.0
|
|
metrics:
|
|
- name: sysUpTime
|
|
oid: 1.3.6.1.2.1.1.3
|
|
type: gauge
|
|
help: The time (in hundredths of a second) since the network management portion
|
|
of the system was last re-initialized. - 1.3.6.1.2.1.1.3
|
|
- name: cpqSeCpuUnitIndex
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.1
|
|
type: gauge
|
|
help: This is a number that uniquely specifies a processor unit - 1.3.6.1.4.1.232.1.2.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuSlot
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.2
|
|
type: gauge
|
|
help: This value represents this processor`s slot - 1.3.6.1.4.1.232.1.2.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuName
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.3
|
|
type: DisplayString
|
|
help: The name of this processor - 1.3.6.1.4.1.232.1.2.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuSpeed
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.4
|
|
type: gauge
|
|
help: The current internal speed of this processor in megahertz - 1.3.6.1.4.1.232.1.2.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuStep
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.5
|
|
type: gauge
|
|
help: This step of the processor - 1.3.6.1.4.1.232.1.2.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuStatus
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.6
|
|
type: gauge
|
|
help: The status of the processor - 1.3.6.1.4.1.232.1.2.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
5: disabled
|
|
- name: cpqSeCpuExtSpeed
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.7
|
|
type: gauge
|
|
help: This is the external frequency in megahertz of the processor bus - 1.3.6.1.4.1.232.1.2.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuDesigner
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.8
|
|
type: gauge
|
|
help: This attribute specifies the manufacturer which designs this CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: intel
|
|
3: amd
|
|
4: cyrix
|
|
5: ti
|
|
6: nexgen
|
|
7: compaq
|
|
8: samsung
|
|
9: mitsubishi
|
|
10: mips
|
|
- name: cpqSeCpuSocketNumber
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.9
|
|
type: gauge
|
|
help: The physical socket number of the CPU chip - 1.3.6.1.4.1.232.1.2.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuThreshPassed
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.10
|
|
type: gauge
|
|
help: CPU threshold passed (Exceeded) - 1.3.6.1.4.1.232.1.2.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unsupported
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqSeCpuHwLocation
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.11
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the CPU - 1.3.6.1.4.1.232.1.2.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuCellTablePtr
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.12
|
|
type: gauge
|
|
help: This is the index for the cell in cpqSeCellTable where this CPU is physically
|
|
located. - 1.3.6.1.4.1.232.1.2.2.1.1.12
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuPowerpodStatus
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.13
|
|
type: gauge
|
|
help: This is the status of CPU power pod - 1.3.6.1.4.1.232.1.2.2.1.1.13
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: notfailed
|
|
2: failed
|
|
- name: cpqSeCpuArchitectureRevision
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.14
|
|
type: DisplayString
|
|
help: This is the CPU architecture revision. - 1.3.6.1.4.1.232.1.2.2.1.1.14
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuCore
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.15
|
|
type: gauge
|
|
help: The number of cores in this CPU module - 1.3.6.1.4.1.232.1.2.2.1.1.15
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUSerialNumber
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.16
|
|
type: DisplayString
|
|
help: The OEM serial number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.16
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUPartNumber
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.17
|
|
type: DisplayString
|
|
help: The OEM part number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.17
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUSerialNumberMfgr
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.18
|
|
type: DisplayString
|
|
help: The manufacturer serial number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.18
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUPartNumberMfgr
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.19
|
|
type: DisplayString
|
|
help: The manufacturer part number of the CPU. - 1.3.6.1.4.1.232.1.2.2.1.1.19
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUCoreIndex
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.20
|
|
type: gauge
|
|
help: This is a number that uniquely identifies a core in a CPU unit. - 1.3.6.1.4.1.232.1.2.2.1.1.20
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUMaxSpeed
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.21
|
|
type: gauge
|
|
help: This is the maximum internal speed in megahertz this processor can support
|
|
- 1.3.6.1.4.1.232.1.2.2.1.1.21
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUCoreThreadIndex
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.22
|
|
type: gauge
|
|
help: This is an unique number to identify the running threads in a CPU core.
|
|
- 1.3.6.1.4.1.232.1.2.2.1.1.22
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUChipGenerationName
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.23
|
|
type: DisplayString
|
|
help: CPU chip generation name e.g - 1.3.6.1.4.1.232.1.2.2.1.1.23
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCPUMultiThreadStatus
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.24
|
|
type: gauge
|
|
help: This OID identifies whether the CPU threading is enabled or not. - 1.3.6.1.4.1.232.1.2.2.1.1.24
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: enabled
|
|
3: disabled
|
|
- name: cpqSeCPUCoreMaxThreads
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.25
|
|
type: gauge
|
|
help: This OID indicates the maximum number of threads that a cpu core is capable
|
|
of. - 1.3.6.1.4.1.232.1.2.2.1.1.25
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuLowPowerStatus
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.26
|
|
type: gauge
|
|
help: Servers like Itanium has capability to lower power supply to CPU if it is
|
|
idle for specified period of time - 1.3.6.1.4.1.232.1.2.2.1.1.26
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: lowpowered
|
|
3: normalpowered
|
|
4: highpowered
|
|
- name: cpqSeCpuPrimary
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.27
|
|
type: gauge
|
|
help: On SMP systems one of the CPU is set to Primary and the other CPUs as secondary
|
|
- 1.3.6.1.4.1.232.1.2.2.1.1.27
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqSeCpuCoreSteppingText
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.28
|
|
type: DisplayString
|
|
help: The processor stepping version string - 1.3.6.1.4.1.232.1.2.2.1.1.28
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuCurrentPerformanceState
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.29
|
|
type: gauge
|
|
help: This OID returns the current performance state of this processor - 1.3.6.1.4.1.232.1.2.2.1.1.29
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuMinPerformanceState
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.30
|
|
type: gauge
|
|
help: This OID returns the minimum performance state set for this processor -
|
|
1.3.6.1.4.1.232.1.2.2.1.1.30
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqSeCpuMaxPerformanceState
|
|
oid: 1.3.6.1.4.1.232.1.2.2.1.1.31
|
|
type: gauge
|
|
help: This OID returns the maximum performance state set for this processor -
|
|
1.3.6.1.4.1.232.1.2.2.1.1.31
|
|
indexes:
|
|
- labelname: cpqSeCpuUnitIndex
|
|
type: gauge
|
|
- name: cpqHoMibRevMajor
|
|
oid: 1.3.6.1.4.1.232.11.1.1
|
|
type: gauge
|
|
help: The Major Revision level of the MIB - 1.3.6.1.4.1.232.11.1.1
|
|
- name: cpqHoMibRevMinor
|
|
oid: 1.3.6.1.4.1.232.11.1.2
|
|
type: gauge
|
|
help: The Minor Revision level of the MIB - 1.3.6.1.4.1.232.11.1.2
|
|
- name: cpqHoMibCondition
|
|
oid: 1.3.6.1.4.1.232.11.1.3
|
|
type: gauge
|
|
help: The overall condition - 1.3.6.1.4.1.232.11.1.3
|
|
enum_values:
|
|
1: unknown
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoOsCommonPollFreq
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.1
|
|
type: gauge
|
|
help: The Insight Agent`s polling frequency - 1.3.6.1.4.1.232.11.2.1.4.1
|
|
- name: cpqHoOsCommonModuleIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.1
|
|
type: gauge
|
|
help: A unique index for this module description. - 1.3.6.1.4.1.232.11.2.1.4.2.1.1
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoOsCommonModuleName
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.2
|
|
type: DisplayString
|
|
help: The module name. - 1.3.6.1.4.1.232.11.2.1.4.2.1.2
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoOsCommonModuleVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.3
|
|
type: DisplayString
|
|
help: The module version in XX.YY format - 1.3.6.1.4.1.232.11.2.1.4.2.1.3
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoOsCommonModuleDate
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.4
|
|
type: OctetString
|
|
help: The module date - 1.3.6.1.4.1.232.11.2.1.4.2.1.4
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoOsCommonModulePurpose
|
|
oid: 1.3.6.1.4.1.232.11.2.1.4.2.1.5
|
|
type: DisplayString
|
|
help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.11.2.1.4.2.1.5
|
|
indexes:
|
|
- labelname: cpqHoOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqHoName
|
|
oid: 1.3.6.1.4.1.232.11.2.2.1
|
|
type: DisplayString
|
|
help: The name of the host operating system (OS). - 1.3.6.1.4.1.232.11.2.2.1
|
|
- name: cpqHoVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.2.2
|
|
type: DisplayString
|
|
help: The version of the host OS. - 1.3.6.1.4.1.232.11.2.2.2
|
|
- name: cpqHoDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.2.3
|
|
type: DisplayString
|
|
help: A further description of the host OS. - 1.3.6.1.4.1.232.11.2.2.3
|
|
- name: cpqHoOsType
|
|
oid: 1.3.6.1.4.1.232.11.2.2.4
|
|
type: gauge
|
|
help: Host Operating system enumeration. - 1.3.6.1.4.1.232.11.2.2.4
|
|
enum_values:
|
|
1: other
|
|
2: netware
|
|
3: windowsnt
|
|
4: sco-unix
|
|
5: unixware
|
|
6: os-2
|
|
7: ms-dos
|
|
8: dos-windows
|
|
9: windows95
|
|
10: windows98
|
|
11: open-vms
|
|
12: nsk
|
|
13: windowsCE
|
|
14: linux
|
|
15: windows2000
|
|
16: tru64UNIX
|
|
17: windows2003
|
|
18: windows2003-x64
|
|
19: solaris
|
|
20: windows2003-ia64
|
|
21: windows2008
|
|
22: windows2008-x64
|
|
23: windows2008-ia64
|
|
24: vmware-esx
|
|
25: vmware-esxi
|
|
26: windows2012
|
|
27: windows7
|
|
28: windows7-x64
|
|
29: windows8
|
|
30: windows8-x64
|
|
31: windows81
|
|
32: windows81-x64
|
|
33: windowsxp
|
|
34: windowsxp-x64
|
|
35: windowsvista
|
|
36: windowsvista-x64
|
|
37: windows2008-r2
|
|
38: windows2012-r2
|
|
39: rhel
|
|
40: rhel-64
|
|
41: solaris-64
|
|
42: sles
|
|
43: sles-64
|
|
44: ubuntu
|
|
45: ubuntu-64
|
|
46: debian
|
|
47: debian-64
|
|
48: linux-64-bit
|
|
49: other-64-bit
|
|
50: centos-32bit
|
|
51: centos-64bit
|
|
52: oracle-linux32
|
|
53: oracle-linux64
|
|
54: apple-osx
|
|
55: windows2016
|
|
56: nanoserver
|
|
57: windows2019
|
|
- name: cpqHoTelnet
|
|
oid: 1.3.6.1.4.1.232.11.2.2.5
|
|
type: gauge
|
|
help: Telnet on socket 23 is available. - 1.3.6.1.4.1.232.11.2.2.5
|
|
enum_values:
|
|
1: other
|
|
2: available
|
|
3: notavailable
|
|
- name: cpqHoSystemRole
|
|
oid: 1.3.6.1.4.1.232.11.2.2.6
|
|
type: DisplayString
|
|
help: The system role - 1.3.6.1.4.1.232.11.2.2.6
|
|
- name: cpqHoSystemRoleDetail
|
|
oid: 1.3.6.1.4.1.232.11.2.2.7
|
|
type: DisplayString
|
|
help: The system detailed description - 1.3.6.1.4.1.232.11.2.2.7
|
|
- name: cpqHoCrashDumpState
|
|
oid: 1.3.6.1.4.1.232.11.2.2.8
|
|
type: gauge
|
|
help: Crash dump state - 1.3.6.1.4.1.232.11.2.2.8
|
|
enum_values:
|
|
1: completememorydump
|
|
2: kernelmemorydump
|
|
3: smallmemorydump
|
|
4: none
|
|
- name: cpqHoCrashDumpCondition
|
|
oid: 1.3.6.1.4.1.232.11.2.2.9
|
|
type: gauge
|
|
help: The condition of the Crash dump configuration. - 1.3.6.1.4.1.232.11.2.2.9
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoCrashDumpMonitoring
|
|
oid: 1.3.6.1.4.1.232.11.2.2.10
|
|
type: gauge
|
|
help: Enable/disable crash dump monitoring - 1.3.6.1.4.1.232.11.2.2.10
|
|
enum_values:
|
|
1: enabled
|
|
2: disabled
|
|
- name: cpqHoMaxLogicalCPUSupported
|
|
oid: 1.3.6.1.4.1.232.11.2.2.11
|
|
type: gauge
|
|
help: Maximum number of logical CPUs supported by Operating System. - 1.3.6.1.4.1.232.11.2.2.11
|
|
- name: cpqHoSystemName
|
|
oid: 1.3.6.1.4.1.232.11.2.2.12
|
|
type: DisplayString
|
|
help: Full computer name of the host - 1.3.6.1.4.1.232.11.2.2.12
|
|
- name: cpqHosysDescr
|
|
oid: 1.3.6.1.4.1.232.11.2.2.13
|
|
type: DisplayString
|
|
help: The value that would be returned in the RFC-1213 sysDescr MIB element -
|
|
1.3.6.1.4.1.232.11.2.2.13
|
|
- name: cpqHoCpuUtilUnitIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.1
|
|
type: gauge
|
|
help: This number uniquely specifies a processor unit - 1.3.6.1.4.1.232.11.2.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilMin
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.2
|
|
type: gauge
|
|
help: The CPU utilization as a percentage of the theoretical maximum during the
|
|
last minute - 1.3.6.1.4.1.232.11.2.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilFiveMin
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.3
|
|
type: gauge
|
|
help: The CPU utilization as a percentage of the theoretical maximum during the
|
|
last five minutes - 1.3.6.1.4.1.232.11.2.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilThirtyMin
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.4
|
|
type: gauge
|
|
help: The CPU utilization as a percentage of the theoretical maximum during the
|
|
last thirty minutes - 1.3.6.1.4.1.232.11.2.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilHour
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.5
|
|
type: gauge
|
|
help: The CPU utilization as a percentage of the theoretical maximum during the
|
|
last hour - 1.3.6.1.4.1.232.11.2.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoCpuUtilHwLocation
|
|
oid: 1.3.6.1.4.1.232.11.2.3.1.1.6
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the CPU - 1.3.6.1.4.1.232.11.2.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoCpuUtilUnitIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.4.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.2
|
|
type: DisplayString
|
|
help: A description of the file system include the GUID. - 1.3.6.1.4.1.232.11.2.4.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysSpaceTotal
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.3
|
|
type: gauge
|
|
help: The file system size in megabytes - 1.3.6.1.4.1.232.11.2.4.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysSpaceUsed
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.4
|
|
type: gauge
|
|
help: The megabytes of file system space currently in use - 1.3.6.1.4.1.232.11.2.4.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysPercentSpaceUsed
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.5
|
|
type: gauge
|
|
help: The percent of file system space currently in use - 1.3.6.1.4.1.232.11.2.4.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysAllocUnitsTotal
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.6
|
|
type: gauge
|
|
help: The total number of files (directory entries) that can be stored on the
|
|
file system if a limit exists other than total space used - 1.3.6.1.4.1.232.11.2.4.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysAllocUnitsUsed
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.7
|
|
type: gauge
|
|
help: The number of files (directory entries) on this file system - 1.3.6.1.4.1.232.11.2.4.1.1.7
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysStatus
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.8
|
|
type: gauge
|
|
help: The Threshold Status - 1.3.6.1.4.1.232.11.2.4.1.1.8
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoFileSysShortDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.4.1.1.9
|
|
type: DisplayString
|
|
help: A description of the file system. - 1.3.6.1.4.1.232.11.2.4.1.1.9
|
|
indexes:
|
|
- labelname: cpqHoFileSysIndex
|
|
type: gauge
|
|
- name: cpqHoFileSysCondition
|
|
oid: 1.3.6.1.4.1.232.11.2.4.2
|
|
type: gauge
|
|
help: The overall condition of File System Threshold - 1.3.6.1.4.1.232.11.2.4.2
|
|
enum_values:
|
|
1: unknown
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoIfPhysMapIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies this entry - 1.3.6.1.4.1.232.11.2.5.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapSlot
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.2
|
|
type: gauge
|
|
help: The number of the slot containing the physical hardware that implements
|
|
this interface - 1.3.6.1.4.1.232.11.2.5.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapIoBaseAddr
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.3
|
|
type: gauge
|
|
help: The base I/O address of the physical hardware that implements this interface.
|
|
- 1.3.6.1.4.1.232.11.2.5.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapIrq
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.4
|
|
type: gauge
|
|
help: The number of the IRQ (interrupt) used for this physical hardware interface
|
|
- 1.3.6.1.4.1.232.11.2.5.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapDma
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.5
|
|
type: gauge
|
|
help: The number of the DMA channel used for this physical hardware interface
|
|
- 1.3.6.1.4.1.232.11.2.5.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapMemBaseAddr
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.6
|
|
type: gauge
|
|
help: The base memory address used by this physical hardware interface - 1.3.6.1.4.1.232.11.2.5.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapPort
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.7
|
|
type: gauge
|
|
help: The port number of the interface for multi-port NICs - 1.3.6.1.4.1.232.11.2.5.1.1.7
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
- name: cpqHoIfPhysMapDuplexState
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.8
|
|
type: gauge
|
|
help: This variable describes the configured duplex state of the NIC. - 1.3.6.1.4.1.232.11.2.5.1.1.8
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: half
|
|
3: full
|
|
- name: cpqHoIfPhysMapCondition
|
|
oid: 1.3.6.1.4.1.232.11.2.5.1.1.9
|
|
type: gauge
|
|
help: The condition of this interface. - 1.3.6.1.4.1.232.11.2.5.1.1.9
|
|
indexes:
|
|
- labelname: cpqHoIfPhysMapIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoIfPhysMapOverallCondition
|
|
oid: 1.3.6.1.4.1.232.11.2.5.2
|
|
type: gauge
|
|
help: The overall condition of all interfaces. - 1.3.6.1.4.1.232.11.2.5.2
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHoSWRunningIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.6.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningName
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.2
|
|
type: DisplayString
|
|
help: The name of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.3
|
|
type: DisplayString
|
|
help: A description of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.4
|
|
type: DisplayString
|
|
help: The version of the software - 1.3.6.1.4.1.232.11.2.6.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningDate
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.5
|
|
type: OctetString
|
|
help: The software date - 1.3.6.1.4.1.232.11.2.6.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningMonitor
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.6
|
|
type: gauge
|
|
help: The user specified monitor option for a process. - 1.3.6.1.4.1.232.11.2.6.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: start
|
|
3: stop
|
|
4: startAndStop
|
|
5: count
|
|
6: startAndCount
|
|
7: countAndStop
|
|
8: startCountAndStop
|
|
- name: cpqHoSWRunningState
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.7
|
|
type: gauge
|
|
help: The current state of monitored process. - 1.3.6.1.4.1.232.11.2.6.1.1.7
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: started
|
|
3: stopped
|
|
- name: cpqHoSWRunningCount
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.8
|
|
type: gauge
|
|
help: For each process name, the number of instances of the process running on
|
|
the system is kept count of, in this variable. - 1.3.6.1.4.1.232.11.2.6.1.1.8
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningCountMin
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.9
|
|
type: gauge
|
|
help: This is the lower threshold on cpqHoSWRunningCount to be set by the user.
|
|
- 1.3.6.1.4.1.232.11.2.6.1.1.9
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningCountMax
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.10
|
|
type: gauge
|
|
help: This is the upper threshold on cpqHoSWRunningCount to be set by the user.
|
|
- 1.3.6.1.4.1.232.11.2.6.1.1.10
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningEventTime
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.11
|
|
type: OctetString
|
|
help: The system time at which the monitored event, as per cpqHoSWRunningMonitor,
|
|
last occurred - 1.3.6.1.4.1.232.11.2.6.1.1.11
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningStatus
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.12
|
|
type: gauge
|
|
help: The overall alarm state of the resources managed by the software, or the
|
|
software itself. - 1.3.6.1.4.1.232.11.2.6.1.1.12
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: normal
|
|
3: warning
|
|
4: minor
|
|
5: major
|
|
6: critical
|
|
7: disabled
|
|
- name: cpqHoSWRunningConfigStatus
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.13
|
|
type: gauge
|
|
help: The configuration state of the software - 1.3.6.1.4.1.232.11.2.6.1.1.13
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: starting
|
|
3: initialized
|
|
4: configured
|
|
5: operational
|
|
- name: cpqHoSWRunningIdentifier
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.14
|
|
type: DisplayString
|
|
help: The unique identifier of the sofware - 1.3.6.1.4.1.232.11.2.6.1.1.14
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
- name: cpqHoSWRunningRedundancyMode
|
|
oid: 1.3.6.1.4.1.232.11.2.6.1.1.15
|
|
type: gauge
|
|
help: When the software is running in a high availability mode, the failover mode
|
|
of this instance of the software. - 1.3.6.1.4.1.232.11.2.6.1.1.15
|
|
indexes:
|
|
- labelname: cpqHoSWRunningIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: unknown
|
|
2: master
|
|
3: backup
|
|
4: slave
|
|
- name: cpqHoSwRunningTrapDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.6.2
|
|
type: DisplayString
|
|
help: The error message for a process monitor event. - 1.3.6.1.4.1.232.11.2.6.2
|
|
- name: cpqHoSwVerNextIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.7.1
|
|
type: gauge
|
|
help: The index of the next available entry in the cpqHoSwVer table - 1.3.6.1.4.1.232.11.2.7.1
|
|
- name: cpqHoSwVerIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies an entry in the cpqHoSwVer table. - 1.3.6.1.4.1.232.11.2.7.2.1.1
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerStatus
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.2
|
|
type: gauge
|
|
help: Status for the software item. - 1.3.6.1.4.1.232.11.2.7.2.1.2
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: loaded
|
|
3: notloaded
|
|
- name: cpqHoSwVerType
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.3
|
|
type: gauge
|
|
help: Type of software item. - 1.3.6.1.4.1.232.11.2.7.2.1.3
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: driver
|
|
3: agent
|
|
4: sysutil
|
|
5: application
|
|
6: keyfile
|
|
7: firmware
|
|
- name: cpqHoSwVerName
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.4
|
|
type: DisplayString
|
|
help: The name of this software item. - 1.3.6.1.4.1.232.11.2.7.2.1.4
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerDescription
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.5
|
|
type: DisplayString
|
|
help: The description of this software item. - 1.3.6.1.4.1.232.11.2.7.2.1.5
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerDate
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.6
|
|
type: OctetString
|
|
help: The date of the software item, if any - 1.3.6.1.4.1.232.11.2.7.2.1.6
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerLocation
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.7
|
|
type: DisplayString
|
|
help: The location of this software item on the server. - 1.3.6.1.4.1.232.11.2.7.2.1.7
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.8
|
|
type: DisplayString
|
|
help: An string that specifies the version of this item. - 1.3.6.1.4.1.232.11.2.7.2.1.8
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerVersionBinary
|
|
oid: 1.3.6.1.4.1.232.11.2.7.2.1.9
|
|
type: DisplayString
|
|
help: An string that specifies the version of this item based on the binary version
|
|
resource. - 1.3.6.1.4.1.232.11.2.7.2.1.9
|
|
indexes:
|
|
- labelname: cpqHoSwVerIndex
|
|
type: gauge
|
|
- name: cpqHoSwVerAgentsVer
|
|
oid: 1.3.6.1.4.1.232.11.2.7.3
|
|
type: DisplayString
|
|
help: A string that specifies the version of the Insight Management Agents running
|
|
on the system. - 1.3.6.1.4.1.232.11.2.7.3
|
|
- name: cpqHoGenericData
|
|
oid: 1.3.6.1.4.1.232.11.2.8.1
|
|
type: DisplayString
|
|
help: Data for the generic trap. - 1.3.6.1.4.1.232.11.2.8.1
|
|
- name: cpqHoCriticalSoftwareUpdateData
|
|
oid: 1.3.6.1.4.1.232.11.2.8.2
|
|
type: DisplayString
|
|
help: Data for the Critical Software Update trap. - 1.3.6.1.4.1.232.11.2.8.2
|
|
- name: cpqHoSwPerfAppErrorDesc
|
|
oid: 1.3.6.1.4.1.232.11.2.9.1
|
|
type: DisplayString
|
|
help: This string holds error information about the last application error that
|
|
occurred in the system. - 1.3.6.1.4.1.232.11.2.9.1
|
|
- name: cpqHoMibStatusArray
|
|
oid: 1.3.6.1.4.1.232.11.2.10.1
|
|
type: OctetString
|
|
help: The MIB Status Array is an array of MIB status structures - 1.3.6.1.4.1.232.11.2.10.1
|
|
- name: cpqHoConfigChangedDate
|
|
oid: 1.3.6.1.4.1.232.11.2.10.2
|
|
type: OctetString
|
|
help: The date/time when the agents were last loaded - 1.3.6.1.4.1.232.11.2.10.2
|
|
- name: cpqHoGUID
|
|
oid: 1.3.6.1.4.1.232.11.2.10.3
|
|
type: OctetString
|
|
help: The globally unique identifier of this physical server - 1.3.6.1.4.1.232.11.2.10.3
|
|
- name: cpqHoCodeServer
|
|
oid: 1.3.6.1.4.1.232.11.2.10.4
|
|
type: gauge
|
|
help: This item indicates how many code server shares are currently configured
|
|
on the system - 1.3.6.1.4.1.232.11.2.10.4
|
|
- name: cpqHoWebMgmtPort
|
|
oid: 1.3.6.1.4.1.232.11.2.10.5
|
|
type: gauge
|
|
help: This item indicates the port used by the Insight Web Agent - 1.3.6.1.4.1.232.11.2.10.5
|
|
- name: cpqHoGUIDCanonical
|
|
oid: 1.3.6.1.4.1.232.11.2.10.6
|
|
type: OctetString
|
|
help: The globally unique identifier in canonical format of this physical server
|
|
- 1.3.6.1.4.1.232.11.2.10.6
|
|
- name: cpqHoMibHealthStatusArray
|
|
oid: 1.3.6.1.4.1.232.11.2.10.7
|
|
type: OctetString
|
|
help: 'The MIB Health Status Array is an array of status values representing an
|
|
overall status in element 0 follwed by server and storage status values as follows:
|
|
Octet Element Field ======== ======= ========= 0 0 Aggregated Status of array
|
|
elements 1 1 Status of element 1 2 2 Status of element 2 - 1.3.6.1.4.1.232.11.2.10.7'
|
|
- name: cpqHoTrapFlags
|
|
oid: 1.3.6.1.4.1.232.11.2.11.1
|
|
type: gauge
|
|
help: The Trap Flags - 1.3.6.1.4.1.232.11.2.11.1
|
|
- name: cpqHoClientLastModified
|
|
oid: 1.3.6.1.4.1.232.11.2.12.1
|
|
type: OctetString
|
|
help: The date/time of the last modification to the client table - 1.3.6.1.4.1.232.11.2.12.1
|
|
- name: cpqHoClientDelete
|
|
oid: 1.3.6.1.4.1.232.11.2.12.2
|
|
type: DisplayString
|
|
help: Setting this variable to the name of a client in the client table will cause
|
|
that row in the table to be deleted - 1.3.6.1.4.1.232.11.2.12.2
|
|
- name: cpqHoClientIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies this entry. - 1.3.6.1.4.1.232.11.2.12.3.1.1
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientName
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.2
|
|
type: DisplayString
|
|
help: The Win95 machine name of this client. - 1.3.6.1.4.1.232.11.2.12.3.1.2
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientIpxAddress
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.3
|
|
type: OctetString
|
|
help: The IPX address for this client, all octets should be set to 0xff if this
|
|
machine does not support IPX - 1.3.6.1.4.1.232.11.2.12.3.1.3
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientIpAddress
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.4
|
|
type: InetAddressIPv4
|
|
help: The IP address for this client, all octets should be set to 0xff if this
|
|
machine does not support IP - 1.3.6.1.4.1.232.11.2.12.3.1.4
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientCommunity
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.5
|
|
type: DisplayString
|
|
help: A community name that can be used to query the client with SNMP - 1.3.6.1.4.1.232.11.2.12.3.1.5
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoClientID
|
|
oid: 1.3.6.1.4.1.232.11.2.12.3.1.6
|
|
type: OctetString
|
|
help: The unique identifier of this client. - 1.3.6.1.4.1.232.11.2.12.3.1.6
|
|
indexes:
|
|
- labelname: cpqHoClientIndex
|
|
type: gauge
|
|
- name: cpqHoPhysicalMemorySize
|
|
oid: 1.3.6.1.4.1.232.11.2.13.1
|
|
type: gauge
|
|
help: Total amount of physical memory as seen by the OS (in megabytes) - 1.3.6.1.4.1.232.11.2.13.1
|
|
- name: cpqHoPhysicalMemoryFree
|
|
oid: 1.3.6.1.4.1.232.11.2.13.2
|
|
type: gauge
|
|
help: The amount of free physical memory (in megabytes) - 1.3.6.1.4.1.232.11.2.13.2
|
|
- name: cpqHoPagingMemorySize
|
|
oid: 1.3.6.1.4.1.232.11.2.13.3
|
|
type: gauge
|
|
help: Total virtual memory available from the OS (in megabytes) - 1.3.6.1.4.1.232.11.2.13.3
|
|
- name: cpqHoPagingMemoryFree
|
|
oid: 1.3.6.1.4.1.232.11.2.13.4
|
|
type: gauge
|
|
help: Available paging memory (in megabytes) - 1.3.6.1.4.1.232.11.2.13.4
|
|
- name: cpqHoBootPagingFileSize
|
|
oid: 1.3.6.1.4.1.232.11.2.13.5
|
|
type: DisplayString
|
|
help: The paging file size of the boot volume in the format xxxMB or xxxGB, where
|
|
xxx is the paging file size in that unit shown right after it - 1.3.6.1.4.1.232.11.2.13.5
|
|
- name: cpqHoBootPagingFileMinimumSize
|
|
oid: 1.3.6.1.4.1.232.11.2.13.6
|
|
type: DisplayString
|
|
help: Minimum paging file size of the boot volume required to save the memory
|
|
dump in the event of a system crash - 1.3.6.1.4.1.232.11.2.13.6
|
|
- name: cpqHoBootPagingFileVolumeFreeSpace
|
|
oid: 1.3.6.1.4.1.232.11.2.13.7
|
|
type: DisplayString
|
|
help: Free space of the boot volume required to save the memory dump in the event
|
|
of a system crash - 1.3.6.1.4.1.232.11.2.13.7
|
|
- name: cpqHoFwVerIndex
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.1
|
|
type: gauge
|
|
help: Firmware Version Index - 1.3.6.1.4.1.232.11.2.14.1.1.1
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerCategory
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.2
|
|
type: gauge
|
|
help: Firmware Version Category. - 1.3.6.1.4.1.232.11.2.14.1.1.2
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: storage
|
|
3: nic
|
|
4: rib
|
|
5: system
|
|
- name: cpqHoFwVerDeviceType
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.3
|
|
type: gauge
|
|
help: Firmware Version Device Type. - 1.3.6.1.4.1.232.11.2.14.1.1.3
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internalArrayController
|
|
3: fibreArrayController
|
|
4: scsiController
|
|
5: fibreChannelTapeController
|
|
6: modularDataRouter
|
|
7: ideCdRomDrive
|
|
8: ideDiskDrive
|
|
9: scsiCdRom-ScsiAttached
|
|
10: scsiDiskDrive-ScsiAttached
|
|
11: scsiTapeDrive-ScsiAttached
|
|
12: scsiTapeLibrary-ScsiAttached
|
|
13: scsiDiskDrive-ArrayAttached
|
|
14: scsiTapeDrive-ArrayAttached
|
|
15: scsiTapeLibrary-ArrayAttached
|
|
16: scsiDiskDrive-FibreAttached
|
|
17: scsiTapeDrive-FibreAttached
|
|
18: scsiTapeLibrary-FibreAttached
|
|
19: scsiEnclosureBackplaneRom-ScsiAttached
|
|
20: scsiEnclosureBackplaneRom-ArrayAttached
|
|
21: scsiEnclosureBackplaneRom-FibreAttached
|
|
22: scsiEnclosureBackplaneRom-ra4x00
|
|
23: systemRom
|
|
24: networkInterfaceController
|
|
25: remoteInsightBoard
|
|
26: sasDiskDrive-SasAttached
|
|
27: sataDiskDrive-SataAttached
|
|
28: usbController
|
|
29: sasControllerAdapter
|
|
30: sataControllerAdapter
|
|
31: systemDevice
|
|
32: fibreChannelHba
|
|
33: convergedNetworkAdapter
|
|
34: ideController
|
|
- name: cpqHoFwVerDisplayName
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.4
|
|
type: DisplayString
|
|
help: Firmware Version Device Display Name - 1.3.6.1.4.1.232.11.2.14.1.1.4
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerVersion
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.5
|
|
type: DisplayString
|
|
help: Firmware Version - 1.3.6.1.4.1.232.11.2.14.1.1.5
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerLocation
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.6
|
|
type: DisplayString
|
|
help: Firmware Version Device Location - 1.3.6.1.4.1.232.11.2.14.1.1.6
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerXmlString
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.7
|
|
type: DisplayString
|
|
help: Firmware Version Xml String - 1.3.6.1.4.1.232.11.2.14.1.1.7
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerKeyString
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.8
|
|
type: DisplayString
|
|
help: Firmware Version Key String - 1.3.6.1.4.1.232.11.2.14.1.1.8
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
- name: cpqHoFwVerUpdateMethod
|
|
oid: 1.3.6.1.4.1.232.11.2.14.1.1.9
|
|
type: gauge
|
|
help: Firmware Version update method. - 1.3.6.1.4.1.232.11.2.14.1.1.9
|
|
indexes:
|
|
- labelname: cpqHoFwVerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: noUpdate
|
|
3: softwareflash
|
|
4: replacePhysicalRom
|
|
- name: cpqHoHWInfoPlatform
|
|
oid: 1.3.6.1.4.1.232.11.2.15.1
|
|
type: gauge
|
|
help: Hardware platform type - 1.3.6.1.4.1.232.11.2.15.1
|
|
enum_values:
|
|
1: unknown
|
|
2: cellular
|
|
3: foundation
|
|
4: virtualMachine
|
|
5: serverBlade
|
|
- name: cpqPwrWarnType
|
|
oid: 1.3.6.1.4.1.232.11.2.16.1
|
|
type: DisplayString
|
|
help: Type of power reading on which the warning is based. - 1.3.6.1.4.1.232.11.2.16.1
|
|
- name: cpqPwrWarnThreshold
|
|
oid: 1.3.6.1.4.1.232.11.2.16.2
|
|
type: gauge
|
|
help: The threshold the power usage must exceed (in Watts). - 1.3.6.1.4.1.232.11.2.16.2
|
|
- name: cpqPwrWarnDuration
|
|
oid: 1.3.6.1.4.1.232.11.2.16.3
|
|
type: gauge
|
|
help: Duration that power usage must be exceeded before warning (in minutes).
|
|
- 1.3.6.1.4.1.232.11.2.16.3
|
|
- name: cpqSerialNum
|
|
oid: 1.3.6.1.4.1.232.11.2.16.4
|
|
type: DisplayString
|
|
help: Serial number of the server. - 1.3.6.1.4.1.232.11.2.16.4
|
|
- name: cpqServerUUID
|
|
oid: 1.3.6.1.4.1.232.11.2.16.5
|
|
type: DisplayString
|
|
help: Server UUID - 1.3.6.1.4.1.232.11.2.16.5
|
|
- name: cpqIdeMibRevMajor
|
|
oid: 1.3.6.1.4.1.232.14.1.1
|
|
type: gauge
|
|
help: The Major Revision level - 1.3.6.1.4.1.232.14.1.1
|
|
- name: cpqIdeMibRevMinor
|
|
oid: 1.3.6.1.4.1.232.14.1.2
|
|
type: gauge
|
|
help: The Minor Revision level - 1.3.6.1.4.1.232.14.1.2
|
|
- name: cpqIdeMibCondition
|
|
oid: 1.3.6.1.4.1.232.14.1.3
|
|
type: gauge
|
|
help: The overall condition - 1.3.6.1.4.1.232.14.1.3
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeOsCommonPollFreq
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.1
|
|
type: gauge
|
|
help: The Insight Agent`s polling frequency - 1.3.6.1.4.1.232.14.2.1.4.1
|
|
- name: cpqIdeOsCommonModuleIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.1
|
|
type: gauge
|
|
help: A unique index for this module description. - 1.3.6.1.4.1.232.14.2.1.4.2.1.1
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeOsCommonModuleName
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.2
|
|
type: DisplayString
|
|
help: The module name. - 1.3.6.1.4.1.232.14.2.1.4.2.1.2
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeOsCommonModuleVersion
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.3
|
|
type: DisplayString
|
|
help: The module version in XX.YY format - 1.3.6.1.4.1.232.14.2.1.4.2.1.3
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeOsCommonModuleDate
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.4
|
|
type: OctetString
|
|
help: The module date - 1.3.6.1.4.1.232.14.2.1.4.2.1.4
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeOsCommonModulePurpose
|
|
oid: 1.3.6.1.4.1.232.14.2.1.4.2.1.5
|
|
type: DisplayString
|
|
help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.14.2.1.4.2.1.5
|
|
indexes:
|
|
- labelname: cpqIdeOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely specifies each device - 1.3.6.1.4.1.232.14.2.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentModel
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.2
|
|
type: DisplayString
|
|
help: IDE Drive Model - 1.3.6.1.4.1.232.14.2.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentSerNum
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.3
|
|
type: DisplayString
|
|
help: IDE Drive Serial Number - 1.3.6.1.4.1.232.14.2.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentFWVers
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.4
|
|
type: DisplayString
|
|
help: IDE Firmware Version - 1.3.6.1.4.1.232.14.2.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.5
|
|
type: gauge
|
|
help: IDE Drive Condition - 1.3.6.1.4.1.232.14.2.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeIdentErrorNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.6
|
|
type: DisplayString
|
|
help: IDE Error Number - 1.3.6.1.4.1.232.14.2.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
- name: cpqIdeIdentType
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.7
|
|
type: gauge
|
|
help: IDE Device Type - 1.3.6.1.4.1.232.14.2.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: disk
|
|
3: tape
|
|
4: printer
|
|
5: processor
|
|
6: wormDrive
|
|
7: cd-rom
|
|
8: scanner
|
|
9: optical
|
|
10: jukeBox
|
|
11: commDev
|
|
- name: cpqIdeIdentTypeExtended
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.8
|
|
type: gauge
|
|
help: IDE Extended Device Type - 1.3.6.1.4.1.232.14.2.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: pdcd
|
|
3: removableDisk
|
|
- name: cpqIdeIdentCondition2
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.9
|
|
type: gauge
|
|
help: IDE Drive Condition - 1.3.6.1.4.1.232.14.2.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeIdentStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.10
|
|
type: gauge
|
|
help: IDE Drive Satus - 1.3.6.1.4.1.232.14.2.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: preFailureDegraded
|
|
4: ultraAtaDegraded
|
|
- name: cpqIdeIdentUltraAtaAvailability
|
|
oid: 1.3.6.1.4.1.232.14.2.2.1.1.11
|
|
type: gauge
|
|
help: This describes the availability of Ultra ATA transfers between this device
|
|
and the controller - 1.3.6.1.4.1.232.14.2.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqIdeIdentIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: noNotSupportedByDeviceAndController
|
|
3: noNotSupportedByDevice
|
|
4: noNotSupportedByController
|
|
5: noDisabledInSetup
|
|
6: yesEnabledInSetup
|
|
- name: cpqIdeControllerIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerOverallCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.2
|
|
type: gauge
|
|
help: IDE Controller Overall Condition - 1.3.6.1.4.1.232.14.2.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeControllerModel
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.3
|
|
type: DisplayString
|
|
help: IDE Controller Model - 1.3.6.1.4.1.232.14.2.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerFwRev
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.4
|
|
type: DisplayString
|
|
help: IDE Controller Firmware Revision - 1.3.6.1.4.1.232.14.2.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerSlot
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.5
|
|
type: gauge
|
|
help: IDE Controller Slot - 1.3.6.1.4.1.232.14.2.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.6
|
|
type: gauge
|
|
help: IDE Channel Host Controller Status - 1.3.6.1.4.1.232.14.2.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
- name: cpqIdeControllerCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.7
|
|
type: gauge
|
|
help: IDE Controller Condition - 1.3.6.1.4.1.232.14.2.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeControllerSerialNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.8
|
|
type: DisplayString
|
|
help: IDE Controller Serial Number - 1.3.6.1.4.1.232.14.2.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerHwLocation
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.9
|
|
type: DisplayString
|
|
help: IDE Controller Hardware Location - 1.3.6.1.4.1.232.14.2.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeControllerPciLocation
|
|
oid: 1.3.6.1.4.1.232.14.2.3.1.1.10
|
|
type: DisplayString
|
|
help: IDE Controller PCI Location - 1.3.6.1.4.1.232.14.2.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqIdeControllerIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskControllerIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.4.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.2
|
|
type: gauge
|
|
help: An index that uniquely identifies each disk. - 1.3.6.1.4.1.232.14.2.4.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskModel
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.3
|
|
type: DisplayString
|
|
help: ATA Disk Model - 1.3.6.1.4.1.232.14.2.4.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskFwRev
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.4
|
|
type: DisplayString
|
|
help: ATA Disk Firmware Revision - 1.3.6.1.4.1.232.14.2.4.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskSerialNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.5
|
|
type: DisplayString
|
|
help: ATA Disk Serial Number - 1.3.6.1.4.1.232.14.2.4.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.6
|
|
type: gauge
|
|
help: ATA Disk Status - 1.3.6.1.4.1.232.14.2.4.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: smartError
|
|
4: failed
|
|
5: ssdWearOut
|
|
- name: cpqIdeAtaDiskCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.7
|
|
type: gauge
|
|
help: ATA Disk Condition - 1.3.6.1.4.1.232.14.2.4.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeAtaDiskCapacity
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.8
|
|
type: gauge
|
|
help: ATA Disk Capacity - 1.3.6.1.4.1.232.14.2.4.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskSmartEnabled
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.9
|
|
type: gauge
|
|
help: ATA Disk S.M.A.R.T Enabled? other(1) The agent cannot determine the state
|
|
of S.M.A.R.T - 1.3.6.1.4.1.232.14.2.4.1.1.9
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqIdeAtaDiskTransferMode
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.10
|
|
type: gauge
|
|
help: ATA Disk Transfer Mode - 1.3.6.1.4.1.232.14.2.4.1.1.10
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: pioMode0
|
|
3: pioMode1
|
|
4: pioMode2
|
|
5: pioMode3
|
|
6: pioMode4
|
|
7: dmaMode0
|
|
8: dmaMode1
|
|
9: dmaMode2
|
|
10: ultraDmaMode0
|
|
11: ultraDmaMode1
|
|
12: ultraDmaMode2
|
|
13: ultraDmaMode3
|
|
14: ultraDmaMode4
|
|
15: ultraDmaMode5
|
|
- name: cpqIdeAtaDiskChannel
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.11
|
|
type: gauge
|
|
help: ATA Disk Channel - 1.3.6.1.4.1.232.14.2.4.1.1.11
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: channel0
|
|
3: channel1
|
|
4: serial
|
|
- name: cpqIdeAtaDiskNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.12
|
|
type: gauge
|
|
help: ATA Disk Number - 1.3.6.1.4.1.232.14.2.4.1.1.12
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: device0
|
|
3: device1
|
|
4: sataDevice0
|
|
5: sataDevice1
|
|
6: sataDevice2
|
|
7: sataDevice3
|
|
8: sataDevice4
|
|
9: sataDevice5
|
|
10: sataDevice6
|
|
11: sataDevice7
|
|
21: bay1
|
|
22: bay2
|
|
23: bay3
|
|
24: bay4
|
|
25: bay5
|
|
26: bay6
|
|
27: bay7
|
|
28: bay8
|
|
29: bay9
|
|
30: bay10
|
|
31: bay11
|
|
32: bay12
|
|
33: bay13
|
|
34: bay14
|
|
- name: cpqIdeAtaDiskLogicalDriveMember
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.13
|
|
type: gauge
|
|
help: Logical Drive Membership? other(1) The agent cannot determine if the ATA
|
|
disk is part of a logical drive - 1.3.6.1.4.1.232.14.2.4.1.1.13
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqIdeAtaDiskIsSpare
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.14
|
|
type: gauge
|
|
help: ATA Disk Spare? other(1) The agent cannot determine if the ATA disk is a
|
|
spare - 1.3.6.1.4.1.232.14.2.4.1.1.14
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqIdeAtaDiskOsName
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.15
|
|
type: DisplayString
|
|
help: ATA Disk OS Name - 1.3.6.1.4.1.232.14.2.4.1.1.15
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskType
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.16
|
|
type: gauge
|
|
help: ATA Disk Type other(1) The agent cannot determine the disk type - 1.3.6.1.4.1.232.14.2.4.1.1.16
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ata
|
|
3: sata
|
|
- name: cpqIdeAtaDiskSataVersion
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.17
|
|
type: gauge
|
|
help: Physical Drive SATA Version - 1.3.6.1.4.1.232.14.2.4.1.1.17
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: sataOne
|
|
3: sataTwo
|
|
- name: cpqIdeAtaDiskMediaType
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.18
|
|
type: gauge
|
|
help: SATA Physical Drive Media Type - 1.3.6.1.4.1.232.14.2.4.1.1.18
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rotatingPlatters
|
|
3: solidState
|
|
- name: cpqIdeAtaDiskSSDWearStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.19
|
|
type: gauge
|
|
help: SATA Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.14.2.4.1.1.19
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: fiftySixDayThreshold
|
|
4: fivePercentThreshold
|
|
5: twoPercentThreshold
|
|
6: ssdWearOut
|
|
- name: cpqIdeAtaDiskPowerOnHours
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.20
|
|
type: counter
|
|
help: SATA Physical Drive Power On Hours - 1.3.6.1.4.1.232.14.2.4.1.1.20
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskSSDPercntEndrnceUsed
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.21
|
|
type: gauge
|
|
help: SATA Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.14.2.4.1.1.21
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskSSDEstTimeRemainingHours
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.22
|
|
type: counter
|
|
help: SATA Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.14.2.4.1.1.22
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskCurrTemperature
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.23
|
|
type: gauge
|
|
help: SATA Physical Drive Current Operating Temperature degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.23
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskTemperatureThreshold
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.24
|
|
type: gauge
|
|
help: SATA Physical Drive Maximum Operating Temperature in degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.24
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskMaximumOperatingTemp
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.25
|
|
type: gauge
|
|
help: SATA Physical Drive Maximum Operating Temperature, as specified by the manufacturer,
|
|
in degrees Celsius - 1.3.6.1.4.1.232.14.2.4.1.1.25
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaDiskDestructiveOperatingTemp
|
|
oid: 1.3.6.1.4.1.232.14.2.4.1.1.26
|
|
type: gauge
|
|
help: SATA Physical Drive Destructive Operating Temperature, as specified by the
|
|
manufacturer, in degrees Celsius, which if exceeded can cause damage to the
|
|
drive - 1.3.6.1.4.1.232.14.2.4.1.1.26
|
|
indexes:
|
|
- labelname: cpqIdeAtaDiskControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtaDiskIndex
|
|
type: gauge
|
|
- name: cpqIdeAtaEraseFailureType
|
|
oid: 1.3.6.1.4.1.232.14.2.4.2
|
|
type: gauge
|
|
help: The value specifies the secure erase status of SATA drive - 1.3.6.1.4.1.232.14.2.4.2
|
|
enum_values:
|
|
1: secureEraseFailed
|
|
2: secureEraseNotSupported
|
|
3: noEraseSupported
|
|
- name: cpqIdeAtapiDeviceControllerIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.5.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
- name: cpqIdeAtapiDeviceIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.2
|
|
type: gauge
|
|
help: An index that uniquely identifies each ATAPI device. - 1.3.6.1.4.1.232.14.2.5.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
- name: cpqIdeAtapiDeviceModel
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.3
|
|
type: DisplayString
|
|
help: ATAPI Device Model - 1.3.6.1.4.1.232.14.2.5.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
- name: cpqIdeAtapiDeviceFwRev
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.4
|
|
type: DisplayString
|
|
help: ATAPI Device Firmware Revision - 1.3.6.1.4.1.232.14.2.5.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
- name: cpqIdeAtapiDeviceType
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.5
|
|
type: gauge
|
|
help: ATAPI Device Type - 1.3.6.1.4.1.232.14.2.5.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: disk
|
|
3: tape
|
|
4: printer
|
|
5: processor
|
|
6: wormDrive
|
|
7: cd-rom
|
|
8: scanner
|
|
9: optical
|
|
10: jukeBox
|
|
11: commDev
|
|
- name: cpqIdeAtapiDeviceTypeExtended
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.6
|
|
type: gauge
|
|
help: ATAPI Extended Device Type - 1.3.6.1.4.1.232.14.2.5.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: pdcd
|
|
3: removableDisk
|
|
- name: cpqIdeAtapiDeviceChannel
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.7
|
|
type: gauge
|
|
help: ATAPI Device Channel - 1.3.6.1.4.1.232.14.2.5.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: channel0
|
|
3: channel1
|
|
- name: cpqIdeAtapiDeviceNumber
|
|
oid: 1.3.6.1.4.1.232.14.2.5.1.1.8
|
|
type: gauge
|
|
help: ATAPI Device Number - 1.3.6.1.4.1.232.14.2.5.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeAtapiDeviceControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeAtapiDeviceIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: device0
|
|
3: device1
|
|
- name: cpqIdeLogicalDriveControllerIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.1
|
|
type: gauge
|
|
help: An index that uniquely identifies each controller. - 1.3.6.1.4.1.232.14.2.6.1.1.1
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveIndex
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.2
|
|
type: gauge
|
|
help: An index that uniquely identifies each logical drive. - 1.3.6.1.4.1.232.14.2.6.1.1.2
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveRaidLevel
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.3
|
|
type: gauge
|
|
help: IDE Logical Drive RAID Level - 1.3.6.1.4.1.232.14.2.6.1.1.3
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: raid0
|
|
3: raid1
|
|
4: raid0plus1
|
|
5: raid5
|
|
6: raid15
|
|
7: volume
|
|
- name: cpqIdeLogicalDriveCapacity
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.4
|
|
type: gauge
|
|
help: IDE Logical Drive Capacity - 1.3.6.1.4.1.232.14.2.6.1.1.4
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveStatus
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.5
|
|
type: gauge
|
|
help: IDE Logical Drive Status - 1.3.6.1.4.1.232.14.2.6.1.1.5
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: rebuilding
|
|
5: failed
|
|
- name: cpqIdeLogicalDriveCondition
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.6
|
|
type: gauge
|
|
help: IDE Logical Drive Condition - 1.3.6.1.4.1.232.14.2.6.1.1.6
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqIdeLogicalDriveDiskIds
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.7
|
|
type: OctetString
|
|
help: IDE Logical Drive Disk ID list - 1.3.6.1.4.1.232.14.2.6.1.1.7
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveStripeSize
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.8
|
|
type: gauge
|
|
help: IDE Logical Drive Stripe Size - 1.3.6.1.4.1.232.14.2.6.1.1.8
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveSpareIds
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.9
|
|
type: OctetString
|
|
help: IDE Logical Drive Spare ID list - 1.3.6.1.4.1.232.14.2.6.1.1.9
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveRebuildingDisk
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.10
|
|
type: gauge
|
|
help: IDE Logical Drive Rebuilding Disk - 1.3.6.1.4.1.232.14.2.6.1.1.10
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqIdeLogicalDriveOsName
|
|
oid: 1.3.6.1.4.1.232.14.2.6.1.1.11
|
|
type: DisplayString
|
|
help: IDE Logical Drive OS Name - 1.3.6.1.4.1.232.14.2.6.1.1.11
|
|
indexes:
|
|
- labelname: cpqIdeLogicalDriveControllerIndex
|
|
type: gauge
|
|
- labelname: cpqIdeLogicalDriveIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.1
|
|
type: gauge
|
|
help: Array Controller Index - 1.3.6.1.4.1.232.3.2.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrModel
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.2
|
|
type: gauge
|
|
help: Array Controller Model - 1.3.6.1.4.1.232.3.2.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ida
|
|
3: idaExpansion
|
|
4: ida-2
|
|
5: smart
|
|
6: smart-2e
|
|
7: smart-2p
|
|
8: smart-2sl
|
|
9: smart-3100es
|
|
10: smart-3200
|
|
11: smart-2dh
|
|
12: smart-221
|
|
13: sa-4250es
|
|
14: sa-4200
|
|
15: sa-integrated
|
|
16: sa-431
|
|
17: sa-5300
|
|
18: raidLc2
|
|
19: sa-5i
|
|
20: sa-532
|
|
21: sa-5312
|
|
22: sa-641
|
|
23: sa-642
|
|
24: sa-6400
|
|
25: sa-6400em
|
|
26: sa-6i
|
|
27: sa-generic
|
|
29: sa-p600
|
|
30: sa-p400
|
|
31: sa-e200
|
|
32: sa-e200i
|
|
33: sa-p400i
|
|
34: sa-p800
|
|
35: sa-e500
|
|
36: sa-p700m
|
|
37: sa-p212
|
|
38: sa-p410
|
|
39: sa-p410i
|
|
40: sa-p411
|
|
41: sa-b110i
|
|
42: sa-p712m
|
|
43: sa-p711m
|
|
44: sa-p812
|
|
45: sw-1210m
|
|
46: sa-p220i
|
|
47: sa-p222
|
|
48: sa-p420
|
|
49: sa-p420i
|
|
50: sa-p421
|
|
51: sa-b320i
|
|
52: sa-p822
|
|
53: sa-p721m
|
|
54: sa-b120i
|
|
55: hps-1224
|
|
56: hps-1228
|
|
57: hps-1228m
|
|
58: sa-p822se
|
|
59: hps-1224e
|
|
60: hps-1228e
|
|
61: hps-1228em
|
|
62: sa-p230i
|
|
63: sa-p430i
|
|
64: sa-p430
|
|
65: sa-p431
|
|
66: sa-p731m
|
|
67: sa-p830i
|
|
68: sa-p830
|
|
69: sa-p831
|
|
70: sa-p530
|
|
71: sa-p531
|
|
72: sa-p244br
|
|
73: sa-p246br
|
|
74: sa-p440
|
|
75: sa-p440ar
|
|
76: sa-p441
|
|
77: sa-p741m
|
|
78: sa-p840
|
|
79: sa-p841
|
|
80: sh-h240ar
|
|
81: sh-h244br
|
|
82: sh-h240
|
|
83: sh-h241
|
|
84: sa-b140i
|
|
85: sh-generic
|
|
86: sa-p240nr
|
|
87: sh-h240nr
|
|
88: sa-p840ar
|
|
89: sa-p542d
|
|
90: s100i
|
|
91: e208i-p
|
|
92: e208i-a
|
|
93: e208i-c
|
|
94: e208e-p
|
|
95: p204i-b
|
|
96: p204i-c
|
|
97: p408i-p
|
|
98: p408i-a
|
|
99: p408e-p
|
|
100: p408i-c
|
|
101: p408e-m
|
|
102: p416ie-m
|
|
103: p816i-a
|
|
104: p408i-sb
|
|
- name: cpqDaCntlrFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.3
|
|
type: DisplayString
|
|
help: Array Controller Firmware Revision - 1.3.6.1.4.1.232.3.2.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrStndIntr
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.4
|
|
type: gauge
|
|
help: The status of the Standard Interface - 1.3.6.1.4.1.232.3.2.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: primary
|
|
3: secondary
|
|
4: disabled
|
|
5: unavailable
|
|
- name: cpqDaCntlrSlot
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.5
|
|
type: gauge
|
|
help: Array Controller Slot - 1.3.6.1.4.1.232.3.2.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.6
|
|
type: gauge
|
|
help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaCntlrProductRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.7
|
|
type: DisplayString
|
|
help: Array Controller Product Revision - 1.3.6.1.4.1.232.3.2.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrPartnerSlot
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.8
|
|
type: gauge
|
|
help: Array Controller Partner Slot - 1.3.6.1.4.1.232.3.2.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrCurrentRole
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.9
|
|
type: gauge
|
|
help: Array Controller Current Role - 1.3.6.1.4.1.232.3.2.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notDuplexed
|
|
3: active
|
|
4: backup
|
|
5: asymActiveActive
|
|
- name: cpqDaCntlrBoardStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.10
|
|
type: gauge
|
|
help: Array Controller Board Status - 1.3.6.1.4.1.232.3.2.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: generalFailure
|
|
4: cableProblem
|
|
5: poweredOff
|
|
6: cacheModuleMissing
|
|
- name: cpqDaCntlrPartnerBoardStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.11
|
|
type: gauge
|
|
help: Array Controller Partner Board Status - 1.3.6.1.4.1.232.3.2.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: generalFailure
|
|
4: cableProblem
|
|
5: poweredOff
|
|
- name: cpqDaCntlrBoardCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.12
|
|
type: gauge
|
|
help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.12
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaCntlrPartnerBoardCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.13
|
|
type: gauge
|
|
help: The condition of the device - 1.3.6.1.4.1.232.3.2.2.1.1.13
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaCntlrDriveOwnership
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.14
|
|
type: gauge
|
|
help: Array Controller Drive Ownership - 1.3.6.1.4.1.232.3.2.2.1.1.14
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: owner
|
|
3: notOwner
|
|
- name: cpqDaCntlrSerialNumber
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.15
|
|
type: DisplayString
|
|
help: Array Controller Serial Number - 1.3.6.1.4.1.232.3.2.2.1.1.15
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrRedundancyType
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.16
|
|
type: gauge
|
|
help: Array Controller Redundancy Type - 1.3.6.1.4.1.232.3.2.2.1.1.16
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notRedundant
|
|
3: driverDuplexing
|
|
4: fwActiveStandby
|
|
5: fwPrimarySecondary
|
|
6: fwActiveActive
|
|
- name: cpqDaCntlrRedundancyError
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.17
|
|
type: gauge
|
|
help: Array Controller Redundancy Error - 1.3.6.1.4.1.232.3.2.2.1.1.17
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: noFailure
|
|
3: noRedundantController
|
|
4: differentHardware
|
|
5: noLink
|
|
6: differentFirmware
|
|
7: differentCache
|
|
8: otherCacheFailure
|
|
9: noDrives
|
|
10: otherNoDrives
|
|
11: unsupportedDrives
|
|
12: expandInProgress
|
|
- name: cpqDaCntlrAccessModuleStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.18
|
|
type: gauge
|
|
help: Array Controller RAID ADG Enabler Module Status - 1.3.6.1.4.1.232.3.2.2.1.1.18
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notPresent
|
|
4: badSignature
|
|
5: badChecksum
|
|
6: fullyFunctional
|
|
7: upgradeFirmware
|
|
- name: cpqDaCntlrDaughterBoardType
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.19
|
|
type: gauge
|
|
help: Array Controller Daughter Board Type - 1.3.6.1.4.1.232.3.2.2.1.1.19
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notPresent
|
|
4: scsiBoardPresent
|
|
5: fibreBoardPresent
|
|
6: arrayExpansionModulePresent
|
|
- name: cpqDaCntlrHwLocation
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.20
|
|
type: DisplayString
|
|
help: A text description of the hardware location of the controller - 1.3.6.1.4.1.232.3.2.2.1.1.20
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrNumberOfBuses
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.21
|
|
type: gauge
|
|
help: Array Controller Number of Buses - 1.3.6.1.4.1.232.3.2.2.1.1.21
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrBlinkTime
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.22
|
|
type: counter
|
|
help: Controller Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.2.1.1.22
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrRebuildPriority
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.23
|
|
type: gauge
|
|
help: Array Controller Rebuild Priority - 1.3.6.1.4.1.232.3.2.2.1.1.23
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: low
|
|
3: medium
|
|
4: high
|
|
5: mediumHigh
|
|
- name: cpqDaCntlrExpandPriority
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.24
|
|
type: gauge
|
|
help: Array Controller Expand Priority - 1.3.6.1.4.1.232.3.2.2.1.1.24
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: low
|
|
3: medium
|
|
4: high
|
|
- name: cpqDaCntlrNumberOfInternalPorts
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.25
|
|
type: gauge
|
|
help: Array Controller Number of Internal Ports - 1.3.6.1.4.1.232.3.2.2.1.1.25
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrNumberOfExternalPorts
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.26
|
|
type: gauge
|
|
help: Array Controller Number of External Ports - 1.3.6.1.4.1.232.3.2.2.1.1.26
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrDriveWriteCacheState
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.27
|
|
type: gauge
|
|
help: Array Controller Drive Write Cache State - 1.3.6.1.4.1.232.3.2.2.1.1.27
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: disabled
|
|
3: enabled
|
|
- name: cpqDaCntlrPartnerSerialNumber
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.28
|
|
type: DisplayString
|
|
help: Array Controller Partner Serial Number - 1.3.6.1.4.1.232.3.2.2.1.1.28
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrOptionRomRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.29
|
|
type: DisplayString
|
|
help: Array Controller Option ROM Revision - 1.3.6.1.4.1.232.3.2.2.1.1.29
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrHbaFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.30
|
|
type: DisplayString
|
|
help: Array Controller HBA Firmware Revision - 1.3.6.1.4.1.232.3.2.2.1.1.30
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrHBAModeOptionRomRev
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.31
|
|
type: DisplayString
|
|
help: Array Controller HBA Mode Option Rom Revision - 1.3.6.1.4.1.232.3.2.2.1.1.31
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrCurrentTemp
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.32
|
|
type: gauge
|
|
help: Array Controller Current Temperature - 1.3.6.1.4.1.232.3.2.2.1.1.32
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrLastLockupCode
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.33
|
|
type: gauge
|
|
help: Array Controller Last Lockup Code - 1.3.6.1.4.1.232.3.2.2.1.1.33
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
- name: cpqDaCntlrEncryptionStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.34
|
|
type: gauge
|
|
help: Array Controller Encryption Status - 1.3.6.1.4.1.232.3.2.2.1.1.34
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notEnabled
|
|
3: enabledLocalKeyMode
|
|
4: enabledRemoteKeyManagerMode
|
|
- name: cpqDaCntlrASICEncptSelfTestStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.35
|
|
type: gauge
|
|
help: Array Controller ASIC Encryption Self Test Status - 1.3.6.1.4.1.232.3.2.2.1.1.35
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: selfTestsPass
|
|
3: selfTestsFailed
|
|
- name: cpqDaCntlrEncryptCspNvramStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.36
|
|
type: gauge
|
|
help: Array Controller Encryption Critical Security Parameter NVRAM Status - 1.3.6.1.4.1.232.3.2.2.1.1.36
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: detectionFailed
|
|
- name: cpqDaCntlrEncryptCryptoOfficerPwdSetStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.37
|
|
type: gauge
|
|
help: Array Controller Encryption Crypto Officer Password Set Status - 1.3.6.1.4.1.232.3.2.2.1.1.37
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrEncryptCntlrPwdSetStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.38
|
|
type: gauge
|
|
help: Array Controller Encryption Controller Password Set Status - 1.3.6.1.4.1.232.3.2.2.1.1.38
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrEncryptCntlrPwdAvailStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.39
|
|
type: gauge
|
|
help: Array Controller Encryption Controller Password Availability Status - 1.3.6.1.4.1.232.3.2.2.1.1.39
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: passwordMissing
|
|
3: passwordActive
|
|
- name: cpqDaCntlrUnencryptedLogDrvCreationPolicy
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.40
|
|
type: gauge
|
|
help: Array Controller Unencrypted Logical Drive Creation Policy - 1.3.6.1.4.1.232.3.2.2.1.1.40
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrEncryptedLogDrvCreationPolicy
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.41
|
|
type: gauge
|
|
help: Array Controller Encrypted Logical Drive Creation Policy - 1.3.6.1.4.1.232.3.2.2.1.1.41
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrEncryptFWLockStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.42
|
|
type: gauge
|
|
help: Array Controller Encryption Firmware Lock Status - 1.3.6.1.4.1.232.3.2.2.1.1.42
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "false"
|
|
3: "true"
|
|
- name: cpqDaCntlrOperatingMode
|
|
oid: 1.3.6.1.4.1.232.3.2.2.1.1.43
|
|
type: gauge
|
|
help: Array Controller Operating Mode - 1.3.6.1.4.1.232.3.2.2.1.1.43
|
|
indexes:
|
|
- labelname: cpqDaCntlrIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: smartArrayMode
|
|
3: smartHbaMode
|
|
4: mixedMode
|
|
- name: cpqDaLogDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.1
|
|
type: gauge
|
|
help: Drive Array Logical Drive Controller Index - 1.3.6.1.4.1.232.3.2.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.2
|
|
type: gauge
|
|
help: Drive Array Logical Drive Index - 1.3.6.1.4.1.232.3.2.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvFaultTol
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.3
|
|
type: gauge
|
|
help: Logical Drive Fault Tolerance - 1.3.6.1.4.1.232.3.2.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: none
|
|
3: mirroring
|
|
4: dataGuard
|
|
5: distribDataGuard
|
|
7: advancedDataGuard
|
|
8: raid50
|
|
9: raid60
|
|
10: raid1Adm
|
|
11: raid10Adm
|
|
12: raid10
|
|
- name: cpqDaLogDrvStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.4
|
|
type: gauge
|
|
help: Logical Drive Status - 1.3.6.1.4.1.232.3.2.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: unconfigured
|
|
5: recovering
|
|
6: readyForRebuild
|
|
7: rebuilding
|
|
8: wrongDrive
|
|
9: badConnect
|
|
10: overheating
|
|
11: shutdown
|
|
12: expanding
|
|
13: notAvailable
|
|
14: queuedForExpansion
|
|
15: multipathAccessDegraded
|
|
16: erasing
|
|
17: predictiveSpareRebuildReady
|
|
18: rapidParityInitInProgress
|
|
19: rapidParityInitPending
|
|
20: noAccessEncryptedNoCntlrKey
|
|
21: unencryptedToEncryptedInProgress
|
|
22: newLogDrvKeyRekeyInProgress
|
|
23: noAccessEncryptedCntlrEncryptnNotEnbld
|
|
24: unencryptedToEncryptedNotStarted
|
|
25: newLogDrvKeyRekeyRequestReceived
|
|
- name: cpqDaLogDrvAutoRel
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.5
|
|
type: gauge
|
|
help: Array Controller Logical Drive Auto-Reliability Delay - 1.3.6.1.4.1.232.3.2.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvRebuildBlks
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.6
|
|
type: counter
|
|
help: Logical Drive Rebuild Blocks Remaining - 1.3.6.1.4.1.232.3.2.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvHasAccel
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.7
|
|
type: gauge
|
|
help: Logical Drive Has Cache Module Board - 1.3.6.1.4.1.232.3.2.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unavailable
|
|
3: enabled
|
|
4: disabled
|
|
- name: cpqDaLogDrvAvailSpares
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.8
|
|
type: OctetString
|
|
help: Drive Array Logical Drive Available Spares - 1.3.6.1.4.1.232.3.2.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvSize
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.9
|
|
type: gauge
|
|
help: Logical Drive Size - 1.3.6.1.4.1.232.3.2.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvPhyDrvIDs
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.10
|
|
type: OctetString
|
|
help: Drive Array Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.3.2.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.11
|
|
type: gauge
|
|
help: The Logical Drive condition - 1.3.6.1.4.1.232.3.2.3.1.1.11
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaLogDrvPercentRebuild
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.12
|
|
type: gauge
|
|
help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.3.2.3.1.1.12
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvStripeSize
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.13
|
|
type: gauge
|
|
help: Logical Drive Stripe Size - 1.3.6.1.4.1.232.3.2.3.1.1.13
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvOsName
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.14
|
|
type: DisplayString
|
|
help: Logical Drive OS Name - 1.3.6.1.4.1.232.3.2.3.1.1.14
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvBlinkTime
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.15
|
|
type: counter
|
|
help: Logical Drive Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.3.1.1.15
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvSpareReplaceMap
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.16
|
|
type: OctetString
|
|
help: Logical Drive Spare To Replacement Drive Map - 1.3.6.1.4.1.232.3.2.3.1.1.16
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvRebuildingPhyDrv
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.17
|
|
type: gauge
|
|
help: Logical Drive Physical Drive Rebuilding Index - 1.3.6.1.4.1.232.3.2.3.1.1.17
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvMultipathAccess
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.18
|
|
type: gauge
|
|
help: Logical Drive Multi-path Access - 1.3.6.1.4.1.232.3.2.3.1.1.18
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notConfigured
|
|
4: pathRedundant
|
|
5: noRedundantPath
|
|
- name: cpqDaLogDrvNmbrOfParityGroups
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.19
|
|
type: gauge
|
|
help: Logical Drive Number Of Parity Groups - 1.3.6.1.4.1.232.3.2.3.1.1.19
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvSplitMirrorBackupLogDrv
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.20
|
|
type: gauge
|
|
help: Logical Drive Split Mirror Backup Logical Drive - 1.3.6.1.4.1.232.3.2.3.1.1.20
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: isNotBackupLogicalDrive
|
|
3: isBackupLogicalDrive
|
|
- name: cpqDaLogDrvCacheVolAccelAssocType
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.21
|
|
type: gauge
|
|
help: Logical Drive Cache Volume Accelerator Association Type - 1.3.6.1.4.1.232.3.2.3.1.1.21
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: nonMember
|
|
3: logicalDriveMember
|
|
4: cacheVolumeMember
|
|
- name: cpqDaLogDrvCacheVolIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.22
|
|
type: gauge
|
|
help: Logical Drive Cache Volume Index - 1.3.6.1.4.1.232.3.2.3.1.1.22
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvRPIPercentComplete
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.23
|
|
type: gauge
|
|
help: Logical Drive Rapid Parity Initialization Percent Complete - 1.3.6.1.4.1.232.3.2.3.1.1.23
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
- name: cpqDaLogDrvSSDSmartPathStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.24
|
|
type: gauge
|
|
help: Logical Drive SSD Smart Path Status - 1.3.6.1.4.1.232.3.2.3.1.1.24
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: updateDriver
|
|
3: ssdSmartPathDisabled
|
|
4: ssdSmartPathEnabled
|
|
- name: cpqDaLogDrvEncryptionStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.3.1.1.25
|
|
type: gauge
|
|
help: Logical Drive Encryption Status - 1.3.6.1.4.1.232.3.2.3.1.1.25
|
|
indexes:
|
|
- labelname: cpqDaLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: encrypted
|
|
3: notEncrypted
|
|
- name: cpqDaPhyDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.1
|
|
type: gauge
|
|
help: Drive Array Physical Drive Controller Index - 1.3.6.1.4.1.232.3.2.5.1.1.1
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvIndex
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.2
|
|
type: gauge
|
|
help: Drive Array Physical Drive Index - 1.3.6.1.4.1.232.3.2.5.1.1.2
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvModel
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.3
|
|
type: DisplayString
|
|
help: Physical Drive Model - 1.3.6.1.4.1.232.3.2.5.1.1.3
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.4
|
|
type: DisplayString
|
|
help: Physical Drive Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.4
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBay
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.5
|
|
type: gauge
|
|
help: Physical Drive Bay Location - 1.3.6.1.4.1.232.3.2.5.1.1.5
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.6
|
|
type: gauge
|
|
help: Physical Drive Status - 1.3.6.1.4.1.232.3.2.5.1.1.6
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: predictiveFailure
|
|
5: erasing
|
|
6: eraseDone
|
|
7: eraseQueued
|
|
8: ssdWearOut
|
|
9: notAuthenticated
|
|
- name: cpqDaPhyDrvFactReallocs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.7
|
|
type: gauge
|
|
help: This shows the number of spare sectors available for remapping at the time
|
|
the physical drive was shipped - 1.3.6.1.4.1.232.3.2.5.1.1.7
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvUsedReallocs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.8
|
|
type: counter
|
|
help: Physical Drive Used Reallocated Sectors - 1.3.6.1.4.1.232.3.2.5.1.1.8
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvRefHours
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.9
|
|
type: counter
|
|
help: Reference Time in hours - 1.3.6.1.4.1.232.3.2.5.1.1.9
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHReads
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.10
|
|
type: counter
|
|
help: Sectors Read (high) - 1.3.6.1.4.1.232.3.2.5.1.1.10
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvReads
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.11
|
|
type: counter
|
|
help: Sectors Read (low) - 1.3.6.1.4.1.232.3.2.5.1.1.11
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHWrites
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.12
|
|
type: counter
|
|
help: Sectors Written (high) - 1.3.6.1.4.1.232.3.2.5.1.1.12
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvWrites
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.13
|
|
type: counter
|
|
help: Sectors Written (low) - 1.3.6.1.4.1.232.3.2.5.1.1.13
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHSeeks
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.14
|
|
type: counter
|
|
help: Total Seeks (high) - 1.3.6.1.4.1.232.3.2.5.1.1.14
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSeeks
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.15
|
|
type: counter
|
|
help: Total Seeks (low) - 1.3.6.1.4.1.232.3.2.5.1.1.15
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHardReadErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.16
|
|
type: counter
|
|
help: Hard Read Errors - 1.3.6.1.4.1.232.3.2.5.1.1.16
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvRecvReadErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.17
|
|
type: counter
|
|
help: Recovered Read Errors - 1.3.6.1.4.1.232.3.2.5.1.1.17
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHardWriteErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.18
|
|
type: counter
|
|
help: Hard Write Errors - 1.3.6.1.4.1.232.3.2.5.1.1.18
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvRecvWriteErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.19
|
|
type: counter
|
|
help: Recovered Write Errors - 1.3.6.1.4.1.232.3.2.5.1.1.19
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHSeekErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.20
|
|
type: counter
|
|
help: Seek Errors (High) - 1.3.6.1.4.1.232.3.2.5.1.1.20
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSeekErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.21
|
|
type: counter
|
|
help: Seek Errors (low) - 1.3.6.1.4.1.232.3.2.5.1.1.21
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSpinupTime
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.22
|
|
type: gauge
|
|
help: Spin up Time in tenths of seconds - 1.3.6.1.4.1.232.3.2.5.1.1.22
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFunctTest1
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.23
|
|
type: gauge
|
|
help: Functional Test 1 - 1.3.6.1.4.1.232.3.2.5.1.1.23
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFunctTest2
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.24
|
|
type: gauge
|
|
help: Functional Test 2 - 1.3.6.1.4.1.232.3.2.5.1.1.24
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFunctTest3
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.25
|
|
type: gauge
|
|
help: Functional Test 3 - 1.3.6.1.4.1.232.3.2.5.1.1.25
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvDrqTimeouts
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.26
|
|
type: counter
|
|
help: DRQ Timeouts - 1.3.6.1.4.1.232.3.2.5.1.1.26
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvOtherTimeouts
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.27
|
|
type: counter
|
|
help: Other Timeouts - 1.3.6.1.4.1.232.3.2.5.1.1.27
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSpinupRetries
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.28
|
|
type: counter
|
|
help: Spin up Retries - 1.3.6.1.4.1.232.3.2.5.1.1.28
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBadRecvReads
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.29
|
|
type: counter
|
|
help: Recovery Failed (Bad) Read Error - 1.3.6.1.4.1.232.3.2.5.1.1.29
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBadRecvWrites
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.30
|
|
type: counter
|
|
help: Recovery Failed (Bad) Write Error - 1.3.6.1.4.1.232.3.2.5.1.1.30
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvFormatErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.31
|
|
type: counter
|
|
help: Format Error - 1.3.6.1.4.1.232.3.2.5.1.1.31
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvPostErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.32
|
|
type: counter
|
|
help: Power On Self Test (Post) Error - 1.3.6.1.4.1.232.3.2.5.1.1.32
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvNotReadyErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.33
|
|
type: counter
|
|
help: Drive Not Ready Errors - 1.3.6.1.4.1.232.3.2.5.1.1.33
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvReallocAborts
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.34
|
|
type: counter
|
|
help: Physical Drive Reallocation Aborts - 1.3.6.1.4.1.232.3.2.5.1.1.34
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvThreshPassed
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.35
|
|
type: gauge
|
|
help: Physical Drive Factory Threshold Passed (Exceeded) - 1.3.6.1.4.1.232.3.2.5.1.1.35
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: "false"
|
|
2: "true"
|
|
- name: cpqDaPhyDrvHasMonInfo
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.36
|
|
type: gauge
|
|
help: Physical Drive Has Monitor Information - 1.3.6.1.4.1.232.3.2.5.1.1.36
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: "false"
|
|
2: "true"
|
|
- name: cpqDaPhyDrvCondition
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.37
|
|
type: gauge
|
|
help: The condition of the device - 1.3.6.1.4.1.232.3.2.5.1.1.37
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqDaPhyDrvHotPlugs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.38
|
|
type: counter
|
|
help: Physical Drive Hot Plug Count - 1.3.6.1.4.1.232.3.2.5.1.1.38
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvMediaErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.39
|
|
type: counter
|
|
help: Physical Drive Media Failure Count - 1.3.6.1.4.1.232.3.2.5.1.1.39
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHardwareErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.40
|
|
type: counter
|
|
help: Physical Drive Hardware Error Count - 1.3.6.1.4.1.232.3.2.5.1.1.40
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvAbortedCmds
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.41
|
|
type: counter
|
|
help: Physical Drive Aborted Command Failures - 1.3.6.1.4.1.232.3.2.5.1.1.41
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSpinUpErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.42
|
|
type: counter
|
|
help: Physical Drive Spin-Up Failure Count - 1.3.6.1.4.1.232.3.2.5.1.1.42
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBadTargetErrs
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.43
|
|
type: counter
|
|
help: Physical Drive Bad Target Count - 1.3.6.1.4.1.232.3.2.5.1.1.43
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvLocation
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.44
|
|
type: gauge
|
|
help: Drive Physical Location - 1.3.6.1.4.1.232.3.2.5.1.1.44
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
4: proLiant
|
|
- name: cpqDaPhyDrvSize
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.45
|
|
type: gauge
|
|
help: Physical Drive Size in MB - 1.3.6.1.4.1.232.3.2.5.1.1.45
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBusFaults
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.46
|
|
type: counter
|
|
help: Physical Drive Bus Fault Count - 1.3.6.1.4.1.232.3.2.5.1.1.46
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvIrqDeglitches
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.47
|
|
type: counter
|
|
help: Physical Drive IRQ Deglitch Count - 1.3.6.1.4.1.232.3.2.5.1.1.47
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvHotPlug
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.48
|
|
type: gauge
|
|
help: Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.3.2.5.1.1.48
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: hotPlug
|
|
3: nonHotPlug
|
|
- name: cpqDaPhyDrvPlacement
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.49
|
|
type: gauge
|
|
help: Physical Drive Placement - 1.3.6.1.4.1.232.3.2.5.1.1.49
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
- name: cpqDaPhyDrvBusNumber
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.50
|
|
type: gauge
|
|
help: Physical Drive SCSI Bus Number - 1.3.6.1.4.1.232.3.2.5.1.1.50
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSerialNum
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.51
|
|
type: DisplayString
|
|
help: Physical Drive Serial Number - 1.3.6.1.4.1.232.3.2.5.1.1.51
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvPreFailMonitoring
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.52
|
|
type: gauge
|
|
help: Drive Array Physical Drive Predictive Failure Monitoring - 1.3.6.1.4.1.232.3.2.5.1.1.52
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notAvailable
|
|
3: available
|
|
- name: cpqDaPhyDrvCurrentWidth
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.53
|
|
type: gauge
|
|
help: Drive Array Physical Drive Current Width - 1.3.6.1.4.1.232.3.2.5.1.1.53
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: narrow
|
|
3: wide16
|
|
- name: cpqDaPhyDrvCurrentSpeed
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.54
|
|
type: gauge
|
|
help: Drive Array Physical Drive Current Data Transfer Speed - 1.3.6.1.4.1.232.3.2.5.1.1.54
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: asynchronous
|
|
3: fast
|
|
4: ultra
|
|
5: ultra2
|
|
6: ultra3
|
|
7: ultra320
|
|
- name: cpqDaPhyDrvFailureCode
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.55
|
|
type: gauge
|
|
help: Drive Array Physical Drive Failure Code - 1.3.6.1.4.1.232.3.2.5.1.1.55
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBlinkTime
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.56
|
|
type: counter
|
|
help: Physical Drive Blink Time Count - 1.3.6.1.4.1.232.3.2.5.1.1.56
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSmartStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.57
|
|
type: gauge
|
|
help: Physical Drive S.M.A.R.T Status - 1.3.6.1.4.1.232.3.2.5.1.1.57
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: replaceDrive
|
|
4: replaceDriveSSDWearOut
|
|
- name: cpqDaPhyDrvConfigurationStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.58
|
|
type: gauge
|
|
help: Physical Drive Configuration Status - 1.3.6.1.4.1.232.3.2.5.1.1.58
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: configured
|
|
3: notConfigured
|
|
- name: cpqDaPhyDrvRotationalSpeed
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.59
|
|
type: gauge
|
|
help: Drive Array Physical Drive Rotational Speed - 1.3.6.1.4.1.232.3.2.5.1.1.59
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rpm7200
|
|
3: rpm10K
|
|
4: rpm15K
|
|
5: rpmSsd
|
|
- name: cpqDaPhyDrvType
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.60
|
|
type: gauge
|
|
help: Physical Drive Type - 1.3.6.1.4.1.232.3.2.5.1.1.60
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: parallelScsi
|
|
3: sata
|
|
4: sas
|
|
- name: cpqDaPhyDrvSataVersion
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.61
|
|
type: gauge
|
|
help: Physical Drive SATA Version - 1.3.6.1.4.1.232.3.2.5.1.1.61
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: sataOne
|
|
3: sataTwo
|
|
- name: cpqDaPhyDrvHostConnector
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.62
|
|
type: DisplayString
|
|
help: Physical Drive Host Connector - 1.3.6.1.4.1.232.3.2.5.1.1.62
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvBoxOnConnector
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.63
|
|
type: gauge
|
|
help: Physical Drive Box on Connector - 1.3.6.1.4.1.232.3.2.5.1.1.63
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvLocationString
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.64
|
|
type: DisplayString
|
|
help: Physical Drive Location String - 1.3.6.1.4.1.232.3.2.5.1.1.64
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvNegotiatedLinkRate
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.65
|
|
type: gauge
|
|
help: Drive Array Physical Drive Negotiated Link Rate - 1.3.6.1.4.1.232.3.2.5.1.1.65
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rate-1-5
|
|
3: rate-3-0
|
|
4: rate-6-0
|
|
5: rate-12-0
|
|
- name: cpqDaPhyDrvNcqSupport
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.66
|
|
type: gauge
|
|
help: Drive Array Physical Drive Native Command Queueing - 1.3.6.1.4.1.232.3.2.5.1.1.66
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: noControllerSupport
|
|
3: noDriveSupport
|
|
4: ncqDisabled
|
|
5: ncqEnabled
|
|
- name: cpqDaPhyDrvPhyCount
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.67
|
|
type: gauge
|
|
help: Drive Array Physical Drive PHY Count - 1.3.6.1.4.1.232.3.2.5.1.1.67
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvMultipathAccess
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.68
|
|
type: gauge
|
|
help: Drive Array Physical Drive Multi-path Access Status - 1.3.6.1.4.1.232.3.2.5.1.1.68
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notConfigured
|
|
4: pathRedundant
|
|
5: noRedundantPath
|
|
6: driveFailed
|
|
- name: cpqDaPhyDrvMediaType
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.69
|
|
type: gauge
|
|
help: Drive Array Physical Drive Media Type - 1.3.6.1.4.1.232.3.2.5.1.1.69
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rotatingPlatters
|
|
3: solidState
|
|
4: smr
|
|
- name: cpqDaPhyDrvCurrentTemperature
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.70
|
|
type: gauge
|
|
help: Drive Array Physical Drive Current Temperature - 1.3.6.1.4.1.232.3.2.5.1.1.70
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvTemperatureThreshold
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.71
|
|
type: gauge
|
|
help: Drive Array Physical Drive Temperature Threshold - 1.3.6.1.4.1.232.3.2.5.1.1.71
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvMaximumTemperature
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.72
|
|
type: gauge
|
|
help: Drive Array Physical Drive Maximum Temperature - 1.3.6.1.4.1.232.3.2.5.1.1.72
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSSDWearStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.73
|
|
type: gauge
|
|
help: Drive Array Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.3.2.5.1.1.73
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: fiftySixDayThreshold
|
|
4: fivePercentThreshold
|
|
5: twoPercentThreshold
|
|
6: ssdWearOut
|
|
- name: cpqDaPhyDrvPowerOnHours
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.74
|
|
type: counter
|
|
help: Drive Array Physical Drive Power On Hours - 1.3.6.1.4.1.232.3.2.5.1.1.74
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSSDPercntEndrnceUsed
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.75
|
|
type: gauge
|
|
help: Drive Array Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.3.2.5.1.1.75
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSSDEstTimeRemainingHours
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.76
|
|
type: counter
|
|
help: Drive Array Physical Drive Solid State Estimated Time Remaining In Hours
|
|
- 1.3.6.1.4.1.232.3.2.5.1.1.76
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvAuthenticationStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.77
|
|
type: gauge
|
|
help: Drive Array Physical Drive Authentication Status - 1.3.6.1.4.1.232.3.2.5.1.1.77
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: authenticationFailed
|
|
4: authenticationPassed
|
|
- name: cpqDaPhyDrvSmartCarrierAppFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.78
|
|
type: gauge
|
|
help: Physical Drive Smart Carrier Application Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.78
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvSmartCarrierBootldrFWRev
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.79
|
|
type: gauge
|
|
help: Physical Drive Smart Carrier Bootloader Firmware Revision - 1.3.6.1.4.1.232.3.2.5.1.1.79
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqDaPhyDrvEncryptionStatus
|
|
oid: 1.3.6.1.4.1.232.3.2.5.1.1.80
|
|
type: gauge
|
|
help: Physical Drive Encryption Status - 1.3.6.1.4.1.232.3.2.5.1.1.80
|
|
indexes:
|
|
- labelname: cpqDaPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqDaPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: encrypted
|
|
3: notEncrypted
|
|
- name: cpqScsiMibRevMajor
|
|
oid: 1.3.6.1.4.1.232.5.1.1
|
|
type: gauge
|
|
help: The Major Revision level - 1.3.6.1.4.1.232.5.1.1
|
|
- name: cpqScsiMibRevMinor
|
|
oid: 1.3.6.1.4.1.232.5.1.2
|
|
type: gauge
|
|
help: The Minor Revision level - 1.3.6.1.4.1.232.5.1.2
|
|
- name: cpqScsiMibCondition
|
|
oid: 1.3.6.1.4.1.232.5.1.3
|
|
type: gauge
|
|
help: The overall condition - 1.3.6.1.4.1.232.5.1.3
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqScsiNw3xDriverName
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.1
|
|
type: DisplayString
|
|
help: SCSI Drive Device Driver Name - 1.3.6.1.4.1.232.5.2.1.1.1
|
|
- name: cpqScsiNw3xDriverVers
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.2
|
|
type: DisplayString
|
|
help: SCSI Drive Device Driver Version - 1.3.6.1.4.1.232.5.2.1.1.2
|
|
- name: cpqScsiNw3xDriverPollType
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.3
|
|
type: gauge
|
|
help: SCSI Drive Device Driver Poll Type - 1.3.6.1.4.1.232.5.2.1.1.3
|
|
enum_values:
|
|
1: other
|
|
2: polled
|
|
3: demand
|
|
- name: cpqScsiNw3xDriverPollTime
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.4
|
|
type: gauge
|
|
help: SCSI Drive Device Driver Poll Time - 1.3.6.1.4.1.232.5.2.1.1.4
|
|
- name: cpqScsiNw3xCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.1
|
|
type: gauge
|
|
help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.1.1.5.1.1
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.2
|
|
type: gauge
|
|
help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.5.1.2
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xXptDesc
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.3
|
|
type: DisplayString
|
|
help: SCSI XPT Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.3
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xXptVers
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.4
|
|
type: DisplayString
|
|
help: SCSI XPT Version - 1.3.6.1.4.1.232.5.2.1.1.5.1.4
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xSimDesc
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.5
|
|
type: DisplayString
|
|
help: SCSI SIM Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.5
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xSimVers
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.6
|
|
type: DisplayString
|
|
help: SCSI SIM Version - 1.3.6.1.4.1.232.5.2.1.1.5.1.6
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xHbaDesc
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.5.1.7
|
|
type: DisplayString
|
|
help: SCSI HBA Description - 1.3.6.1.4.1.232.5.2.1.1.5.1.7
|
|
indexes:
|
|
- labelname: cpqScsiNw3xCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xBusIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xStatCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.1
|
|
type: gauge
|
|
help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.1
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xStatBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.2
|
|
type: gauge
|
|
help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.2
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xStatLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.3
|
|
type: gauge
|
|
help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.1.1.6.1.3
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xTotalReads
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.4
|
|
type: counter
|
|
help: SCSI Logical Drive Total Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.4
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xTotalWrites
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.5
|
|
type: counter
|
|
help: SCSI Logical Drive Total Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.5
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xCorrReads
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.6
|
|
type: counter
|
|
help: SCSI Logical Drive Corrected Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.6
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xCorrWrites
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.7
|
|
type: counter
|
|
help: SCSI Logical Drive Corrected Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.7
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xFatalReads
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.8
|
|
type: counter
|
|
help: SCSI Logical Drive Fatal Reads - 1.3.6.1.4.1.232.5.2.1.1.6.1.8
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xFatalWrites
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.6.1.9
|
|
type: counter
|
|
help: SCSI Logical Drive Fatal Writes - 1.3.6.1.4.1.232.5.2.1.1.6.1.9
|
|
indexes:
|
|
- labelname: cpqScsiNw3xStatCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xStatLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xVolCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.1
|
|
type: gauge
|
|
help: SCSI Cntlr Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.1
|
|
indexes:
|
|
- labelname: cpqScsiNw3xVolCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xVolBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.2
|
|
type: gauge
|
|
help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.2
|
|
indexes:
|
|
- labelname: cpqScsiNw3xVolCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xVolLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.3
|
|
type: gauge
|
|
help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.1.1.7.1.3
|
|
indexes:
|
|
- labelname: cpqScsiNw3xVolCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiNw3xVolMap
|
|
oid: 1.3.6.1.4.1.232.5.2.1.1.7.1.4
|
|
type: OctetString
|
|
help: SCSI Drive Volume Map - 1.3.6.1.4.1.232.5.2.1.1.7.1.4
|
|
indexes:
|
|
- labelname: cpqScsiNw3xVolCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiNw3xVolLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonPollFreq
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.1
|
|
type: gauge
|
|
help: The agent`s polling frequency - 1.3.6.1.4.1.232.5.2.1.4.1
|
|
- name: cpqScsiOsCommonModuleIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.1
|
|
type: gauge
|
|
help: A unique index for this module description. - 1.3.6.1.4.1.232.5.2.1.4.2.1.1
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonModuleName
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.2
|
|
type: DisplayString
|
|
help: The module name. - 1.3.6.1.4.1.232.5.2.1.4.2.1.2
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonModuleVersion
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.3
|
|
type: DisplayString
|
|
help: The module version in XX.YY format - 1.3.6.1.4.1.232.5.2.1.4.2.1.3
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonModuleDate
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.4
|
|
type: OctetString
|
|
help: The module date - 1.3.6.1.4.1.232.5.2.1.4.2.1.4
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiOsCommonModulePurpose
|
|
oid: 1.3.6.1.4.1.232.5.2.1.4.2.1.5
|
|
type: DisplayString
|
|
help: The purpose of the module described in this entry. - 1.3.6.1.4.1.232.5.2.1.4.2.1.5
|
|
indexes:
|
|
- labelname: cpqScsiOsCommonModuleIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.1
|
|
type: gauge
|
|
help: SCSI Controller Index - 1.3.6.1.4.1.232.5.2.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.2
|
|
type: gauge
|
|
help: SCSI Bus Index - 1.3.6.1.4.1.232.5.2.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrModel
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.3
|
|
type: gauge
|
|
help: SCSI Controller Model - 1.3.6.1.4.1.232.5.2.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: cpqs710
|
|
3: cpqs94
|
|
4: cpqs810p
|
|
5: cpqs825e
|
|
6: cpqs825p
|
|
7: cpqs974p
|
|
8: cpqs875p
|
|
9: extended
|
|
10: cpqs895p
|
|
11: cpqs896p
|
|
12: cpqa789x
|
|
13: cpqs876t
|
|
14: hpu320
|
|
15: hpu320r
|
|
16: generic
|
|
17: hp1u320g2
|
|
18: hp1u320g1
|
|
19: hpSc11Xe
|
|
- name: cpqScsiCntlrFWVers
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.4
|
|
type: DisplayString
|
|
help: SCSI Controller Firmware Version - 1.3.6.1.4.1.232.5.2.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrSWVers
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.5
|
|
type: DisplayString
|
|
help: SCSI Controller Software Version - 1.3.6.1.4.1.232.5.2.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrSlot
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.6
|
|
type: gauge
|
|
help: SCSI Controller Slot - 1.3.6.1.4.1.232.5.2.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrStatus
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.7
|
|
type: gauge
|
|
help: SCSI Controller Status - 1.3.6.1.4.1.232.5.2.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
- name: cpqScsiCntlrHardResets
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.8
|
|
type: counter
|
|
help: SCSI Controller Hard Resets - 1.3.6.1.4.1.232.5.2.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrSoftResets
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.9
|
|
type: counter
|
|
help: SCSI Controller Soft Resets - 1.3.6.1.4.1.232.5.2.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrTimeouts
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.10
|
|
type: counter
|
|
help: SCSI Controller Time-outs - 1.3.6.1.4.1.232.5.2.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrBaseIOAddr
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.11
|
|
type: gauge
|
|
help: SCSI Controller Base I/O Address - 1.3.6.1.4.1.232.5.2.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrCondition
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.12
|
|
type: gauge
|
|
help: SCSI Controller Condition - 1.3.6.1.4.1.232.5.2.2.1.1.12
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqScsiCntlrSerialNum
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.13
|
|
type: DisplayString
|
|
help: SCSI Controller Serial Number - 1.3.6.1.4.1.232.5.2.2.1.1.13
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrBusWidth
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.14
|
|
type: gauge
|
|
help: SCSI Controller Data Bus Width - 1.3.6.1.4.1.232.5.2.2.1.1.14
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: narrow
|
|
3: wide16
|
|
- name: cpqScsiCntlrModelExtended
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.15
|
|
type: DisplayString
|
|
help: SCSI Controller Model Name - 1.3.6.1.4.1.232.5.2.2.1.1.15
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrHwLocation
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.16
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the SCSI controller - 1.3.6.1.4.1.232.5.2.2.1.1.16
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiCntlrPciLocation
|
|
oid: 1.3.6.1.4.1.232.5.2.2.1.1.17
|
|
type: DisplayString
|
|
help: A string designating the PCI device location for the controller, following
|
|
the format DDDD:BB:DD.F, where DDDD is the PCI domain number, BB is the PCI
|
|
bus number, DD is the PCI device number, and F is the PCI function number -
|
|
1.3.6.1.4.1.232.5.2.2.1.1.17
|
|
indexes:
|
|
- labelname: cpqScsiCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCntlrBusIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.1
|
|
type: gauge
|
|
help: SCSI Logical Drive Controller Index - 1.3.6.1.4.1.232.5.2.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.2
|
|
type: gauge
|
|
help: SCSI Logical Drive Bus Index - 1.3.6.1.4.1.232.5.2.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.3
|
|
type: gauge
|
|
help: SCSI Logical Drive Index - 1.3.6.1.4.1.232.5.2.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvFaultTol
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.4
|
|
type: gauge
|
|
help: SCSI Logical Drive Fault Tolerance - 1.3.6.1.4.1.232.5.2.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: none
|
|
3: mirroring
|
|
4: dataGuard
|
|
5: distribDataGuard
|
|
6: enhancedMirroring
|
|
- name: cpqScsiLogDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.5
|
|
type: gauge
|
|
help: SCSI Logical Drive Status - 1.3.6.1.4.1.232.5.2.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: unconfigured
|
|
5: recovering
|
|
6: readyForRebuild
|
|
7: rebuilding
|
|
8: wrongDrive
|
|
9: badConnect
|
|
10: degraded
|
|
11: disabled
|
|
- name: cpqScsiLogDrvSize
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.6
|
|
type: gauge
|
|
help: SCSI Logical Drive Size - 1.3.6.1.4.1.232.5.2.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvPhyDrvIDs
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.7
|
|
type: OctetString
|
|
help: SCSI Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.5.2.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.8
|
|
type: gauge
|
|
help: SCSI Logical Drive Condition - 1.3.6.1.4.1.232.5.2.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqScsiLogDrvStripeSize
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.9
|
|
type: gauge
|
|
help: Logical Drive Stripe Size - 1.3.6.1.4.1.232.5.2.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvAvailSpares
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.10
|
|
type: OctetString
|
|
help: SCSI Logical Drive Available Spares - 1.3.6.1.4.1.232.5.2.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvPercentRebuild
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.11
|
|
type: gauge
|
|
help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.5.2.3.1.1.11
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiLogDrvOsName
|
|
oid: 1.3.6.1.4.1.232.5.2.3.1.1.12
|
|
type: DisplayString
|
|
help: Logical Drive OS Name - 1.3.6.1.4.1.232.5.2.3.1.1.12
|
|
indexes:
|
|
- labelname: cpqScsiLogDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiLogDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.1
|
|
type: gauge
|
|
help: SCSI Physical Drive Controller Index - 1.3.6.1.4.1.232.5.2.4.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.2
|
|
type: gauge
|
|
help: SCSI Physical Drive Bus Index - 1.3.6.1.4.1.232.5.2.4.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.3
|
|
type: gauge
|
|
help: SCSI Physical Drive Index - 1.3.6.1.4.1.232.5.2.4.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvModel
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.4
|
|
type: DisplayString
|
|
help: SCSI Physical Drive Model - 1.3.6.1.4.1.232.5.2.4.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvFWRev
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.5
|
|
type: DisplayString
|
|
help: SCSI Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.2.4.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvVendor
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.6
|
|
type: DisplayString
|
|
help: SCSI Physical Drive Vendor - 1.3.6.1.4.1.232.5.2.4.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvSize
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.7
|
|
type: gauge
|
|
help: SCSI Physical Drive Size in MB - 1.3.6.1.4.1.232.5.2.4.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvScsiID
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.8
|
|
type: gauge
|
|
help: SCSI Physical Drive SCSI ID - 1.3.6.1.4.1.232.5.2.4.1.1.8
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.9
|
|
type: gauge
|
|
help: SCSI Physical Drive Status - 1.3.6.1.4.1.232.5.2.4.1.1.9
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: notConfigured
|
|
5: badCable
|
|
6: missingWasOk
|
|
7: missingWasFailed
|
|
8: predictiveFailure
|
|
9: missingWasPredictiveFailure
|
|
10: offline
|
|
11: missingWasOffline
|
|
12: hardError
|
|
- name: cpqScsiPhyDrvServiceHours
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.10
|
|
type: counter
|
|
help: SCSI Physical Drive Service Time in hours - 1.3.6.1.4.1.232.5.2.4.1.1.10
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHighReadSectors
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.11
|
|
type: counter
|
|
help: SCSI Physical Drive Sectors Read (high) - 1.3.6.1.4.1.232.5.2.4.1.1.11
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvLowReadSectors
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.12
|
|
type: counter
|
|
help: SCSI Physical Drive Sectors Read (low) - 1.3.6.1.4.1.232.5.2.4.1.1.12
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHighWriteSectors
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.13
|
|
type: counter
|
|
help: SCSI Physical Drive Sectors Written (high) - 1.3.6.1.4.1.232.5.2.4.1.1.13
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvLowWriteSectors
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.14
|
|
type: counter
|
|
help: SCSI Physical Drive Sectors Written (low) - 1.3.6.1.4.1.232.5.2.4.1.1.14
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHardReadErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.15
|
|
type: counter
|
|
help: SCSI Physical Drive Hard Read Errors - 1.3.6.1.4.1.232.5.2.4.1.1.15
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHardWriteErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.16
|
|
type: counter
|
|
help: SCSI Physical Drive Hard Write Errors - 1.3.6.1.4.1.232.5.2.4.1.1.16
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvEccCorrReads
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.17
|
|
type: counter
|
|
help: SCSI Physical Drive ECC Corrected Read Errors (high) - 1.3.6.1.4.1.232.5.2.4.1.1.17
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvRecvReadErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.18
|
|
type: counter
|
|
help: SCSI Physical Drive Recovered Read Errors - 1.3.6.1.4.1.232.5.2.4.1.1.18
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvRecvWriteErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.19
|
|
type: counter
|
|
help: SCSI Physical Drive Recovered Write Errors - 1.3.6.1.4.1.232.5.2.4.1.1.19
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvSeekErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.20
|
|
type: counter
|
|
help: SCSI Physical Drive Seek Errors - 1.3.6.1.4.1.232.5.2.4.1.1.20
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvSpinupTime
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.21
|
|
type: gauge
|
|
help: SCSI Physical Drive Spin up Time (tenths of seconds) - 1.3.6.1.4.1.232.5.2.4.1.1.21
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvUsedReallocs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.22
|
|
type: counter
|
|
help: SCSI Physical Drive Used Reallocation Sectors - 1.3.6.1.4.1.232.5.2.4.1.1.22
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvTimeouts
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.23
|
|
type: counter
|
|
help: SCSI Physical Drive Time-out Errors - 1.3.6.1.4.1.232.5.2.4.1.1.23
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvPostErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.24
|
|
type: counter
|
|
help: SCSI Physical Drive Power On Self Test (POST) Errors - 1.3.6.1.4.1.232.5.2.4.1.1.24
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvPostErrCode
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.25
|
|
type: gauge
|
|
help: SCSI Physical Drive Last POST Error Code - 1.3.6.1.4.1.232.5.2.4.1.1.25
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.26
|
|
type: gauge
|
|
help: SCSI Physical Drive Condition - 1.3.6.1.4.1.232.5.2.4.1.1.26
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqScsiPhyDrvFuncTest1
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.27
|
|
type: gauge
|
|
help: SCSI Physical Drive Functional Test 1 - 1.3.6.1.4.1.232.5.2.4.1.1.27
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvFuncTest2
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.28
|
|
type: gauge
|
|
help: SCSI Physical Drive Functional Test 2 - 1.3.6.1.4.1.232.5.2.4.1.1.28
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvStatsPreserved
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.29
|
|
type: gauge
|
|
help: SCSI Physical Drive Statistics Preservation Method - 1.3.6.1.4.1.232.5.2.4.1.1.29
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: inNVRAM
|
|
3: onDisk
|
|
4: noCPUSupport
|
|
5: noFreeNVRAM
|
|
6: noDrvSupport
|
|
7: noSoftwareSupport
|
|
8: statsNotSupported
|
|
- name: cpqScsiPhyDrvSerialNum
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.30
|
|
type: DisplayString
|
|
help: SCSI Physical Drive Serial Number - 1.3.6.1.4.1.232.5.2.4.1.1.30
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvLocation
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.31
|
|
type: gauge
|
|
help: SCSI Physical Drive Location - 1.3.6.1.4.1.232.5.2.4.1.1.31
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: proliant
|
|
- name: cpqScsiPhyDrvParent
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.32
|
|
type: gauge
|
|
help: SCSI Physical Drive Parent - 1.3.6.1.4.1.232.5.2.4.1.1.32
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvSectorSize
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.33
|
|
type: gauge
|
|
help: SCSI Physical Drive Sector Size in Bytes - 1.3.6.1.4.1.232.5.2.4.1.1.33
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvHotPlug
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.34
|
|
type: gauge
|
|
help: SCSI Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.2.4.1.1.34
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: hotPlug
|
|
3: nonHotPlug
|
|
- name: cpqScsiPhyDrvPlacement
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.35
|
|
type: gauge
|
|
help: SCSI Physical Drive Placement - 1.3.6.1.4.1.232.5.2.4.1.1.35
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
- name: cpqScsiPhyDrvPreFailMonitoring
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.36
|
|
type: gauge
|
|
help: SCSI Physical Drive Predictive Failure Monitoring - 1.3.6.1.4.1.232.5.2.4.1.1.36
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notAvailable
|
|
3: available
|
|
- name: cpqScsiPhyDrvOsName
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.37
|
|
type: DisplayString
|
|
help: Physical Drive OS Name - 1.3.6.1.4.1.232.5.2.4.1.1.37
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqScsiPhyDrvRotationalSpeed
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.38
|
|
type: gauge
|
|
help: SCSI Physical Drive Rotational Speed - 1.3.6.1.4.1.232.5.2.4.1.1.38
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rpm7200
|
|
3: rpm10K
|
|
4: rpm15K
|
|
- name: cpqScsiPhyDrvMemberLogDrv
|
|
oid: 1.3.6.1.4.1.232.5.2.4.1.1.39
|
|
type: gauge
|
|
help: The Physical Drive is a Member of a Logical Drive - 1.3.6.1.4.1.232.5.2.4.1.1.39
|
|
indexes:
|
|
- labelname: cpqScsiPhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: member
|
|
3: spare
|
|
4: nonMember
|
|
- name: cpqScsiTargetCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.1
|
|
type: gauge
|
|
help: SCSI Target Controller Index - 1.3.6.1.4.1.232.5.2.5.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.2
|
|
type: gauge
|
|
help: SCSI Target Bus Index - 1.3.6.1.4.1.232.5.2.5.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.3
|
|
type: gauge
|
|
help: SCSI Target Device Index - 1.3.6.1.4.1.232.5.2.5.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetType
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.4
|
|
type: gauge
|
|
help: SCSI Device Type - 1.3.6.1.4.1.232.5.2.5.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: disk
|
|
3: tape
|
|
4: printer
|
|
5: processor
|
|
6: wormDrive
|
|
7: cd-rom
|
|
8: scanner
|
|
9: optical
|
|
10: jukeBox
|
|
11: commDev
|
|
- name: cpqScsiTargetModel
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.5
|
|
type: DisplayString
|
|
help: SCSI Device Model - 1.3.6.1.4.1.232.5.2.5.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetFWRev
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.6
|
|
type: DisplayString
|
|
help: SCSI Device Firmware Revision - 1.3.6.1.4.1.232.5.2.5.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetVendor
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.7
|
|
type: DisplayString
|
|
help: SCSI Device Vendor - 1.3.6.1.4.1.232.5.2.5.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetParityErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.8
|
|
type: counter
|
|
help: SCSI Device Bus Parity Errors - 1.3.6.1.4.1.232.5.2.5.1.1.8
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetPhaseErrs
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.9
|
|
type: counter
|
|
help: SCSI Device Bus Phase Errors - 1.3.6.1.4.1.232.5.2.5.1.1.9
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetSelectTimeouts
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.10
|
|
type: counter
|
|
help: SCSI Device Bus Select Time-outs - 1.3.6.1.4.1.232.5.2.5.1.1.10
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetMsgRejects
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.11
|
|
type: counter
|
|
help: SCSI Device Bus Message Rejects - 1.3.6.1.4.1.232.5.2.5.1.1.11
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetNegPeriod
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.12
|
|
type: gauge
|
|
help: SCSI Device Negotiated Period - 1.3.6.1.4.1.232.5.2.5.1.1.12
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetLocation
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.13
|
|
type: gauge
|
|
help: SCSI Device Location - 1.3.6.1.4.1.232.5.2.5.1.1.13
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: proliant
|
|
- name: cpqScsiTargetNegSpeed
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.14
|
|
type: gauge
|
|
help: SCSI Device Negotiated Speed - 1.3.6.1.4.1.232.5.2.5.1.1.14
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetPhysWidth
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.15
|
|
type: gauge
|
|
help: SCSI Device Data Bus Physical Width - 1.3.6.1.4.1.232.5.2.5.1.1.15
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: narrow
|
|
3: wide16
|
|
- name: cpqScsiTargetNegWidth
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.16
|
|
type: gauge
|
|
help: SCSI Device Data Bus Negotiated Width - 1.3.6.1.4.1.232.5.2.5.1.1.16
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
- name: cpqScsiTargetTypeExtended
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.17
|
|
type: gauge
|
|
help: SCSI Extended Device Type - 1.3.6.1.4.1.232.5.2.5.1.1.17
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: pdcd
|
|
3: removableDisk
|
|
4: dltAutoloader
|
|
5: cdJukebox
|
|
6: cr3500
|
|
7: autoloader
|
|
- name: cpqScsiTargetCurrentSpeed
|
|
oid: 1.3.6.1.4.1.232.5.2.5.1.1.18
|
|
type: gauge
|
|
help: SCSI Device Current Data Transfer Speed - 1.3.6.1.4.1.232.5.2.5.1.1.18
|
|
indexes:
|
|
- labelname: cpqScsiTargetCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiTargetScsiIdIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: asynchronous
|
|
3: fast
|
|
4: ultra
|
|
5: ultra2
|
|
6: ultra3
|
|
7: scsi1
|
|
8: ultra4
|
|
- name: cpqScsiCdDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.1
|
|
type: gauge
|
|
help: SCSI CD-ROM Drive Controller Index - 1.3.6.1.4.1.232.5.2.6.1.1.1
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.2
|
|
type: gauge
|
|
help: SCSI CD-ROM Drive Bus Index - 1.3.6.1.4.1.232.5.2.6.1.1.2
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.3
|
|
type: gauge
|
|
help: SCSI CD-ROM Drive Index - 1.3.6.1.4.1.232.5.2.6.1.1.3
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.4
|
|
type: gauge
|
|
help: SCSI CD-ROM Drive Logical Unit Index - 1.3.6.1.4.1.232.5.2.6.1.1.4
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvModel
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.5
|
|
type: DisplayString
|
|
help: SCSI CD Device Model - 1.3.6.1.4.1.232.5.2.6.1.1.5
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvVendor
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.6
|
|
type: DisplayString
|
|
help: SCSI CD Drive Vendor - 1.3.6.1.4.1.232.5.2.6.1.1.6
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqScsiCdDrvFwRev
|
|
oid: 1.3.6.1.4.1.232.5.2.6.1.1.7
|
|
type: DisplayString
|
|
help: SCSI CD-ROM Firmware Revision - 1.3.6.1.4.1.232.5.2.6.1.1.7
|
|
indexes:
|
|
- labelname: cpqScsiCdDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqScsiCdDrvLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.1
|
|
type: gauge
|
|
help: SCSI CD Library Controller Index - 1.3.6.1.4.1.232.5.2.6.2.1.1
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.2
|
|
type: gauge
|
|
help: SCSI CD Library Bus Index - 1.3.6.1.4.1.232.5.2.6.2.1.2
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.3
|
|
type: gauge
|
|
help: SCSI CD Library Device Index - 1.3.6.1.4.1.232.5.2.6.2.1.3
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.4
|
|
type: gauge
|
|
help: SCSI CD Library Logical Unit Index - 1.3.6.1.4.1.232.5.2.6.2.1.4
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryCondition
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.5
|
|
type: gauge
|
|
help: CD Library Condition - 1.3.6.1.4.1.232.5.2.6.2.1.5
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqCdLibraryStatus
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.6
|
|
type: gauge
|
|
help: CD Library Status - 1.3.6.1.4.1.232.5.2.6.2.1.6
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
4: offline
|
|
- name: cpqCdLibraryModel
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.7
|
|
type: DisplayString
|
|
help: SCSI CD Library Device Model - 1.3.6.1.4.1.232.5.2.6.2.1.7
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryVendor
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.8
|
|
type: DisplayString
|
|
help: SCSI CD Library Vendor - 1.3.6.1.4.1.232.5.2.6.2.1.8
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibrarySerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.9
|
|
type: DisplayString
|
|
help: CD Library Serial Number - 1.3.6.1.4.1.232.5.2.6.2.1.9
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryDriveList
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.10
|
|
type: OctetString
|
|
help: CD Library Drive List This is a data structure containing the list of CD
|
|
drive ids that are present in this library - 1.3.6.1.4.1.232.5.2.6.2.1.10
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryFwRev
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.11
|
|
type: DisplayString
|
|
help: SCSI CD Library Firmware Revision - 1.3.6.1.4.1.232.5.2.6.2.1.11
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqCdLibraryFwSubtype
|
|
oid: 1.3.6.1.4.1.232.5.2.6.2.1.12
|
|
type: gauge
|
|
help: SCSI CD library Firmware Subtype - 1.3.6.1.4.1.232.5.2.6.2.1.12
|
|
indexes:
|
|
- labelname: cpqCdLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqCdLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqScsiTrapPkts
|
|
oid: 1.3.6.1.4.1.232.5.3.1
|
|
type: counter
|
|
help: The total number of trap packets issued by the SCSI enterprise since the
|
|
instrument agent was loaded. - 1.3.6.1.4.1.232.5.3.1
|
|
- name: cpqScsiTrapLogMaxSize
|
|
oid: 1.3.6.1.4.1.232.5.3.2
|
|
type: gauge
|
|
help: The maximum number of entries that will currently be kept in the trap log
|
|
- 1.3.6.1.4.1.232.5.3.2
|
|
- name: cpqScsiTrapLogIndex
|
|
oid: 1.3.6.1.4.1.232.5.3.3.1.1
|
|
type: gauge
|
|
help: The value of this object uniquely identifies this trapLogEntry at this time
|
|
- 1.3.6.1.4.1.232.5.3.3.1.1
|
|
indexes:
|
|
- labelname: cpqScsiTrapLogIndex
|
|
type: gauge
|
|
- name: cpqScsiTrapType
|
|
oid: 1.3.6.1.4.1.232.5.3.3.1.2
|
|
type: gauge
|
|
help: The type of the trap event that this entry describes - 1.3.6.1.4.1.232.5.3.3.1.2
|
|
indexes:
|
|
- labelname: cpqScsiTrapLogIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: cpqScsiCntlrStatusChange
|
|
2: cpqScsiLogDrvStatusChange
|
|
3: cpqScsiPhyDrvStatusChange
|
|
5001: cpqScsi2CntlrStatusChange
|
|
5002: cpqScsi2LogDrvStatusChange
|
|
5003: cpqScsi2PhyDrvStatusChange
|
|
- name: cpqScsiTrapTime
|
|
oid: 1.3.6.1.4.1.232.5.3.3.1.3
|
|
type: OctetString
|
|
help: The time of the trap event that this entry describes - 1.3.6.1.4.1.232.5.3.3.1.3
|
|
indexes:
|
|
- labelname: cpqScsiTrapLogIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.1
|
|
type: gauge
|
|
help: Tape Physical Drive Controller Index - 1.3.6.1.4.1.232.5.4.1.1.1.1
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.2
|
|
type: gauge
|
|
help: Tape Physical Drive Bus Index - 1.3.6.1.4.1.232.5.4.1.1.1.2
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.3
|
|
type: gauge
|
|
help: Tape Physical Drive Index - 1.3.6.1.4.1.232.5.4.1.1.1.3
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.4
|
|
type: gauge
|
|
help: Tape Physical Drive Logical Unit Index - 1.3.6.1.4.1.232.5.4.1.1.1.4
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvType
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.5
|
|
type: gauge
|
|
help: Tape Device Type - 1.3.6.1.4.1.232.5.4.1.1.1.5
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: cpqDat4-16
|
|
3: cpqDatAuto
|
|
4: cpqDat2-8
|
|
5: cpqDlt10-20
|
|
6: cpqDlt20-40
|
|
7: cpqDlt15-30
|
|
8: cpqDlt35-70
|
|
9: cpqDat4-8
|
|
10: cpqSlr4-8
|
|
11: cpqDat12-24
|
|
12: cpqDatAuto12-24
|
|
13: cpqMlr16-32
|
|
14: cpqAit35
|
|
15: cpqAit50
|
|
16: cpqDat20-40
|
|
17: cpqDlt40-80
|
|
18: cpqDatAuto20-40
|
|
19: cpqSuperDlt1
|
|
20: cpqAit35Lvd
|
|
21: cpqCompaq
|
|
- name: cpqTapePhyDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.6
|
|
type: gauge
|
|
help: Tape Physical Drive Status - 1.3.6.1.4.1.232.5.4.1.1.1.6
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqTapePhyDrvMagSize
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.7
|
|
type: gauge
|
|
help: Tape Physical Drive Magazine Size - 1.3.6.1.4.1.232.5.4.1.1.1.7
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.8
|
|
type: DisplayString
|
|
help: Tape Physical Drive Serial Number - 1.3.6.1.4.1.232.5.4.1.1.1.8
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvCleanReq
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.9
|
|
type: gauge
|
|
help: Tape Physical Drive Cleaning Required Status - 1.3.6.1.4.1.232.5.4.1.1.1.9
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqTapePhyDrvCleanTapeRepl
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.10
|
|
type: gauge
|
|
help: Tape Physical Drive Cleaning Tape Replacement Status - 1.3.6.1.4.1.232.5.4.1.1.1.10
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqTapePhyDrvFwSubtype
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.11
|
|
type: gauge
|
|
help: Tape Physical Drive Firmware Subtype - 1.3.6.1.4.1.232.5.4.1.1.1.11
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvName
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.12
|
|
type: DisplayString
|
|
help: Tape Physical Drive Name - 1.3.6.1.4.1.232.5.4.1.1.1.12
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvCleanTapeCount
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.13
|
|
type: gauge
|
|
help: Tape Physical Drive Cleaning Tape Count - 1.3.6.1.4.1.232.5.4.1.1.1.13
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvFwRev
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.14
|
|
type: DisplayString
|
|
help: Tape Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.4.1.1.1.14
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.15
|
|
type: gauge
|
|
help: Tape Physical Drive Status - 1.3.6.1.4.1.232.5.4.1.1.1.15
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
4: failed
|
|
5: offline
|
|
6: missingWasOk
|
|
7: missingWasFailed
|
|
8: missingWasOffline
|
|
- name: cpqTapePhyDrvHotPlug
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.16
|
|
type: gauge
|
|
help: Tape Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.4.1.1.1.16
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: hotPlug
|
|
3: nonHotPlug
|
|
- name: cpqTapePhyDrvPlacement
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.17
|
|
type: gauge
|
|
help: Tape Physical Drive Placement - 1.3.6.1.4.1.232.5.4.1.1.1.17
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
- name: cpqTapePhyDrvLibraryDrive
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.18
|
|
type: gauge
|
|
help: Tape Physical Drive Library Drive - 1.3.6.1.4.1.232.5.4.1.1.1.18
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: "true"
|
|
3: "false"
|
|
- name: cpqTapePhyDrvLoaderName
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.19
|
|
type: DisplayString
|
|
help: Tape Autoloader Name - 1.3.6.1.4.1.232.5.4.1.1.1.19
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvLoaderFwRev
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.20
|
|
type: DisplayString
|
|
help: Tape Autoloader Firmware Revision - 1.3.6.1.4.1.232.5.4.1.1.1.20
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapePhyDrvLoaderSerialNum
|
|
oid: 1.3.6.1.4.1.232.5.4.1.1.1.21
|
|
type: DisplayString
|
|
help: Tape Autoloader Serial Number - 1.3.6.1.4.1.232.5.4.1.1.1.21
|
|
indexes:
|
|
- labelname: cpqTapePhyDrvCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapePhyDrvLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.1
|
|
type: gauge
|
|
help: SCSI Counters Controller Index - 1.3.6.1.4.1.232.5.4.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.2
|
|
type: gauge
|
|
help: SCSI Counters Bus Index - 1.3.6.1.4.1.232.5.4.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.3
|
|
type: gauge
|
|
help: SCSI Counters Device Index - 1.3.6.1.4.1.232.5.4.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.4
|
|
type: gauge
|
|
help: SCSI Counters Logical Unit Index - 1.3.6.1.4.1.232.5.4.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersReWrites
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.5
|
|
type: counter
|
|
help: Tape Device Re-write count - 1.3.6.1.4.1.232.5.4.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersReReads
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.6
|
|
type: counter
|
|
help: Tape Device Re-read count - 1.3.6.1.4.1.232.5.4.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersTotalErrors
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.7
|
|
type: counter
|
|
help: Tape Device Total Errors - 1.3.6.1.4.1.232.5.4.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersTotalUncorrectable
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.8
|
|
type: counter
|
|
help: Tape Device Total Uncorrectable Errors - 1.3.6.1.4.1.232.5.4.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeCountersTotalBytes
|
|
oid: 1.3.6.1.4.1.232.5.4.2.1.1.9
|
|
type: counter
|
|
help: Tape Device Total Bytes - 1.3.6.1.4.1.232.5.4.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqTapeCountersCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeCountersLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryCntlrIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.1
|
|
type: gauge
|
|
help: SCSI Library Controller Index - 1.3.6.1.4.1.232.5.4.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryBusIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.2
|
|
type: gauge
|
|
help: SCSI Library Bus Index - 1.3.6.1.4.1.232.5.4.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryScsiIdIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.3
|
|
type: gauge
|
|
help: SCSI Library Device Index - 1.3.6.1.4.1.232.5.4.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryLunIndex
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.4
|
|
type: gauge
|
|
help: SCSI Library Logical Unit Index - 1.3.6.1.4.1.232.5.4.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryCondition
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.5
|
|
type: gauge
|
|
help: Tape Library Status - 1.3.6.1.4.1.232.5.4.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqTapeLibraryStatus
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.6
|
|
type: gauge
|
|
help: Error code returned by the last library error. - 1.3.6.1.4.1.232.5.4.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryDoorStatus
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.7
|
|
type: gauge
|
|
help: Status of the library door - 1.3.6.1.4.1.232.5.4.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: closed
|
|
3: open
|
|
4: notSupported
|
|
- name: cpqTapeLibraryStatHours
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.8
|
|
type: counter
|
|
help: The number of hours of operation for the library. - 1.3.6.1.4.1.232.5.4.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryStatMoves
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.9
|
|
type: counter
|
|
help: The number of tape moves for the library loader arm. - 1.3.6.1.4.1.232.5.4.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryName
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.10
|
|
type: DisplayString
|
|
help: Tape Library Name. - 1.3.6.1.4.1.232.5.4.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibrarySerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.11
|
|
type: DisplayString
|
|
help: Tape Library Serial Number - 1.3.6.1.4.1.232.5.4.3.1.1.11
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryDriveList
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.12
|
|
type: OctetString
|
|
help: Tape Library Drive List This is a data structure containing the list of
|
|
tape drive ids that are present in this library - 1.3.6.1.4.1.232.5.4.3.1.1.12
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryState
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.13
|
|
type: gauge
|
|
help: Tape Library Status - 1.3.6.1.4.1.232.5.4.3.1.1.13
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
5: offline
|
|
- name: cpqTapeLibraryTemperature
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.14
|
|
type: gauge
|
|
help: Tape Library Temperature Status - 1.3.6.1.4.1.232.5.4.3.1.1.14
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: ok
|
|
4: safeTempExceeded
|
|
5: maxTempExceeded
|
|
- name: cpqTapeLibraryRedundancy
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.15
|
|
type: gauge
|
|
help: Tape Library Redundancy Status - 1.3.6.1.4.1.232.5.4.3.1.1.15
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: capable
|
|
4: notCapable
|
|
5: active
|
|
- name: cpqTapeLibraryHotSwap
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.16
|
|
type: gauge
|
|
help: Tape Library Hot Swap Status - 1.3.6.1.4.1.232.5.4.3.1.1.16
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: capable
|
|
4: notCapable
|
|
- name: cpqTapeLibraryFwRev
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.17
|
|
type: DisplayString
|
|
help: Tape Library Firmware Revision - 1.3.6.1.4.1.232.5.4.3.1.1.17
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqTapeLibraryTapeList
|
|
oid: 1.3.6.1.4.1.232.5.4.3.1.1.18
|
|
type: OctetString
|
|
help: Tape Library Drive List This is a data structure containing the list of
|
|
tape drive ids that are present in this library - 1.3.6.1.4.1.232.5.4.3.1.1.18
|
|
indexes:
|
|
- labelname: cpqTapeLibraryCntlrIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryBusIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryScsiIdIndex
|
|
type: gauge
|
|
- labelname: cpqTapeLibraryLunIndex
|
|
type: gauge
|
|
- name: cpqSasHbaIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.1
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Index - 1.3.6.1.4.1.232.5.5.1.1.1.1
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaHwLocation
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.2
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter Hardware Location - 1.3.6.1.4.1.232.5.5.1.1.1.2
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaModel
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.3
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Model - 1.3.6.1.4.1.232.5.5.1.1.1.3
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: generic
|
|
3: sas8int
|
|
4: sas4int
|
|
5: sasSc44Ge
|
|
6: sasSc40Ge
|
|
7: sasSc08Ge
|
|
8: sasSc08e
|
|
9: sasH220i
|
|
10: sasH221
|
|
11: sasH210i
|
|
12: sasH220
|
|
13: sasH222
|
|
14: sasP824ip
|
|
- name: cpqSasHbaStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.4
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Status - 1.3.6.1.4.1.232.5.5.1.1.1.4
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: failed
|
|
- name: cpqSasHbaCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.5
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Condition - 1.3.6.1.4.1.232.5.5.1.1.1.5
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasHbaOverallCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.6
|
|
type: gauge
|
|
help: SAS Host Bus Adapter Overall Condition - 1.3.6.1.4.1.232.5.5.1.1.1.6
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasHbaSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.7
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter Serial Number - 1.3.6.1.4.1.232.5.5.1.1.1.7
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaFwVersion
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.8
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter Firmware Version - 1.3.6.1.4.1.232.5.5.1.1.1.8
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaBiosVersion
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.9
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter BIOS Version - 1.3.6.1.4.1.232.5.5.1.1.1.9
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasHbaPciLocation
|
|
oid: 1.3.6.1.4.1.232.5.5.1.1.1.10
|
|
type: DisplayString
|
|
help: SAS Host Bus Adapter PCI Location - 1.3.6.1.4.1.232.5.5.1.1.1.10
|
|
indexes:
|
|
- labelname: cpqSasHbaIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvHbaIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.1
|
|
type: gauge
|
|
help: SAS Physical Drive HBA Index - 1.3.6.1.4.1.232.5.5.2.1.1.1
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.2
|
|
type: gauge
|
|
help: SAS Physical Drive Index - 1.3.6.1.4.1.232.5.5.2.1.1.2
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvLocationString
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.3
|
|
type: DisplayString
|
|
help: SAS Physical Drive Location String - 1.3.6.1.4.1.232.5.5.2.1.1.3
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvModel
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.4
|
|
type: DisplayString
|
|
help: SAS Physical Drive Model - 1.3.6.1.4.1.232.5.5.2.1.1.4
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.5
|
|
type: gauge
|
|
help: SAS Physical Drive Status - 1.3.6.1.4.1.232.5.5.2.1.1.5
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: predictiveFailure
|
|
4: offline
|
|
5: failed
|
|
6: missingWasOk
|
|
7: missingWasPredictiveFailure
|
|
8: missingWasOffline
|
|
9: missingWasFailed
|
|
10: ssdWearOut
|
|
11: missingWasSSDWearOut
|
|
12: notAuthenticated
|
|
13: missingWasNotAuthenticated
|
|
- name: cpqSasPhyDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.6
|
|
type: gauge
|
|
help: SAS Physical Drive Condition - 1.3.6.1.4.1.232.5.5.2.1.1.6
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasPhyDrvFWRev
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.7
|
|
type: DisplayString
|
|
help: SAS Physical Drive Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.7
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSize
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.8
|
|
type: gauge
|
|
help: SAS Physical Drive Size in MB - 1.3.6.1.4.1.232.5.5.2.1.1.8
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvUsedReallocs
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.9
|
|
type: counter
|
|
help: SAS Physical Drive Used Reallocation Sectors - 1.3.6.1.4.1.232.5.5.2.1.1.9
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.10
|
|
type: DisplayString
|
|
help: SAS Physical Drive Serial Number - 1.3.6.1.4.1.232.5.5.2.1.1.10
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvMemberLogDrv
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.11
|
|
type: gauge
|
|
help: The Physical Drive is a Member of a Logical Drive - 1.3.6.1.4.1.232.5.5.2.1.1.11
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: member
|
|
3: spare
|
|
4: nonMember
|
|
- name: cpqSasPhyDrvRotationalSpeed
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.12
|
|
type: gauge
|
|
help: SAS Physical Drive Rotational Speed - 1.3.6.1.4.1.232.5.5.2.1.1.12
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rpm7200
|
|
3: rpm10K
|
|
4: rpm15K
|
|
5: rpmSsd
|
|
- name: cpqSasPhyDrvOsName
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.13
|
|
type: DisplayString
|
|
help: SAS Physical Drive OS Name - 1.3.6.1.4.1.232.5.5.2.1.1.13
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvPlacement
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.14
|
|
type: gauge
|
|
help: SAS Physical Drive Placement - 1.3.6.1.4.1.232.5.5.2.1.1.14
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: internal
|
|
3: external
|
|
- name: cpqSasPhyDrvHotPlug
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.15
|
|
type: gauge
|
|
help: SAS Physical Drive Hot Plug Support Status - 1.3.6.1.4.1.232.5.5.2.1.1.15
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: hotPlug
|
|
3: nonHotPlug
|
|
- name: cpqSasPhyDrvType
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.16
|
|
type: gauge
|
|
help: SAS Physical Drive Type - 1.3.6.1.4.1.232.5.5.2.1.1.16
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: sas
|
|
3: sata
|
|
- name: cpqSasPhyDrvSasAddress
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.17
|
|
type: DisplayString
|
|
help: SAS Physical Drive SAS Address - 1.3.6.1.4.1.232.5.5.2.1.1.17
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvMediaType
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.18
|
|
type: gauge
|
|
help: SAS Physical Drive Media Type - 1.3.6.1.4.1.232.5.5.2.1.1.18
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: rotatingPlatters
|
|
3: solidState
|
|
- name: cpqSasPhyDrvSSDWearStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.19
|
|
type: gauge
|
|
help: SAS Physical Drive Solid State Disk Wear Status - 1.3.6.1.4.1.232.5.5.2.1.1.19
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: fiftySixDayThreshold
|
|
4: fivePercentThreshold
|
|
5: twoPercentThreshold
|
|
6: ssdWearOut
|
|
- name: cpqSasPhyDrvPowerOnHours
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.20
|
|
type: counter
|
|
help: SAS Physical Drive Power On Hours - 1.3.6.1.4.1.232.5.5.2.1.1.20
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSSDPercntEndrnceUsed
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.21
|
|
type: gauge
|
|
help: SAS Physical Drive Solid State Percent Endurance Used - 1.3.6.1.4.1.232.5.5.2.1.1.21
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSSDEstTimeRemainingHours
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.22
|
|
type: counter
|
|
help: SAS Physical Drive Solid State Estimated Time Remaining In Hours - 1.3.6.1.4.1.232.5.5.2.1.1.22
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvAuthenticationStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.23
|
|
type: gauge
|
|
help: SAS Physical Drive Authentication Status - 1.3.6.1.4.1.232.5.5.2.1.1.23
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: authenticationFailed
|
|
4: authenticationPassed
|
|
- name: cpqSasPhyDrvSmartCarrierAppFWRev
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.24
|
|
type: gauge
|
|
help: SAS Physical Drive Smart Carrier Application Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.24
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSmartCarrierBootldrFWRev
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.25
|
|
type: gauge
|
|
help: SAS Physical Drive Smart Carrier Bootloader Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.25
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvCurrTemperature
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.26
|
|
type: gauge
|
|
help: SAS Physical Drive Current Operating Temperature degrees Celsius - 1.3.6.1.4.1.232.5.5.2.1.1.26
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvTemperatureThreshold
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.27
|
|
type: gauge
|
|
help: SAS Physical Drive Maximum Operating Temperature in degrees Celsius - 1.3.6.1.4.1.232.5.5.2.1.1.27
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSsBoxModel
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.28
|
|
type: DisplayString
|
|
help: SAS Physical Drive Box Model - 1.3.6.1.4.1.232.5.5.2.1.1.28
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSsBoxFwRev
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.29
|
|
type: DisplayString
|
|
help: SAS Physical Drive Box Firmware Revision - 1.3.6.1.4.1.232.5.5.2.1.1.29
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSsBoxVendor
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.30
|
|
type: DisplayString
|
|
help: SAS Physical Drive Box Vendor This is the SAS drive box`s vendor name -
|
|
1.3.6.1.4.1.232.5.5.2.1.1.30
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasPhyDrvSsBoxSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.5.2.1.1.31
|
|
type: DisplayString
|
|
help: SAS Physical Drive Box Serial Number - 1.3.6.1.4.1.232.5.5.2.1.1.31
|
|
indexes:
|
|
- labelname: cpqSasPhyDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasPhyDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvHbaIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.1
|
|
type: gauge
|
|
help: SAS Logical Drive HBA Index - 1.3.6.1.4.1.232.5.5.3.1.1.1
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.2
|
|
type: gauge
|
|
help: SAS Logical Drive Index - 1.3.6.1.4.1.232.5.5.3.1.1.2
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvRaidLevel
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.3
|
|
type: gauge
|
|
help: SAS Logical Drive RAID Level - 1.3.6.1.4.1.232.5.5.3.1.1.3
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: raid0
|
|
3: raid1
|
|
4: raid0plus1
|
|
5: raid5
|
|
6: raid15
|
|
7: volume
|
|
- name: cpqSasLogDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.4
|
|
type: gauge
|
|
help: SAS Logical Drive Status - 1.3.6.1.4.1.232.5.5.3.1.1.4
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: rebuilding
|
|
5: failed
|
|
6: offline
|
|
- name: cpqSasLogDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.5
|
|
type: gauge
|
|
help: SAS Logical Drive Condition - 1.3.6.1.4.1.232.5.5.3.1.1.5
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasLogDrvRebuildingDisk
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.6
|
|
type: gauge
|
|
help: SAS Logical Drive Rebuilding Disk - 1.3.6.1.4.1.232.5.5.3.1.1.6
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvCapacity
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.7
|
|
type: gauge
|
|
help: SAS Logical Drive Size - 1.3.6.1.4.1.232.5.5.3.1.1.7
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvStripeSize
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.8
|
|
type: gauge
|
|
help: SAS Logical Drive Stripe Size - 1.3.6.1.4.1.232.5.5.3.1.1.8
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvPhyDrvIds
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.9
|
|
type: OctetString
|
|
help: SAS Logical Drive Physical Drive IDs - 1.3.6.1.4.1.232.5.5.3.1.1.9
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvSpareIds
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.10
|
|
type: OctetString
|
|
help: SAS Logical Drive Spare Drive IDs - 1.3.6.1.4.1.232.5.5.3.1.1.10
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvOsName
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.11
|
|
type: DisplayString
|
|
help: SAS Logical Drive OS Name - 1.3.6.1.4.1.232.5.5.3.1.1.11
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasLogDrvRebuildingPercent
|
|
oid: 1.3.6.1.4.1.232.5.5.3.1.1.12
|
|
type: gauge
|
|
help: Logical Drive Percent Rebuild - 1.3.6.1.4.1.232.5.5.3.1.1.12
|
|
indexes:
|
|
- labelname: cpqSasLogDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasLogDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvHbaIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.1
|
|
type: gauge
|
|
help: SAS Tape Drive HBA Index - 1.3.6.1.4.1.232.5.5.4.1.1.1
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvIndex
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.2
|
|
type: gauge
|
|
help: SAS Tape Drive Index - 1.3.6.1.4.1.232.5.5.4.1.1.2
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvLocationString
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.3
|
|
type: DisplayString
|
|
help: SAS Tape Drive Location String - 1.3.6.1.4.1.232.5.5.4.1.1.3
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvName
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.4
|
|
type: DisplayString
|
|
help: SAS Tape Drive Name - 1.3.6.1.4.1.232.5.5.4.1.1.4
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvStatus
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.5
|
|
type: gauge
|
|
help: SAS Physical Drive Status - 1.3.6.1.4.1.232.5.5.4.1.1.5
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: offline
|
|
- name: cpqSasTapeDrvCondition
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.6
|
|
type: gauge
|
|
help: SAS Tape Drive Condition - 1.3.6.1.4.1.232.5.5.4.1.1.6
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqSasTapeDrvFWRev
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.7
|
|
type: DisplayString
|
|
help: SAS Tape Drive Firmware Revision - 1.3.6.1.4.1.232.5.5.4.1.1.7
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvSerialNumber
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.8
|
|
type: DisplayString
|
|
help: SAS Tape Drive Serial Number - 1.3.6.1.4.1.232.5.5.4.1.1.8
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqSasTapeDrvSasAddress
|
|
oid: 1.3.6.1.4.1.232.5.5.4.1.1.9
|
|
type: DisplayString
|
|
help: SAS Tape Drive SAS Address - 1.3.6.1.4.1.232.5.5.4.1.1.9
|
|
indexes:
|
|
- labelname: cpqSasTapeDrvHbaIndex
|
|
type: gauge
|
|
- labelname: cpqSasTapeDrvIndex
|
|
type: gauge
|
|
- name: cpqHeResMem2ModuleSize
|
|
oid: 1.3.6.1.4.1.232.6.2.14.13.1.6
|
|
type: gauge
|
|
help: Module memory size in kilobytes - 1.3.6.1.4.1.232.6.2.14.13.1.6
|
|
indexes:
|
|
- labelname: cpqHeResMem2Module
|
|
type: gauge
|
|
- name: cpqHePowerMeterSupport
|
|
oid: 1.3.6.1.4.1.232.6.2.15.1
|
|
type: gauge
|
|
help: This value specifies whether Power Meter is supported by this Server -
|
|
1.3.6.1.4.1.232.6.2.15.1
|
|
enum_values:
|
|
1: other
|
|
2: supported
|
|
3: unsupported
|
|
- name: cpqHePowerMeterStatus
|
|
oid: 1.3.6.1.4.1.232.6.2.15.2
|
|
type: gauge
|
|
help: This value specifies whether Power Meter reading is supported by this Server -
|
|
1.3.6.1.4.1.232.6.2.15.2
|
|
enum_values:
|
|
1: other
|
|
2: present
|
|
3: absent
|
|
- name: cpqHePowerMeterCurrReading
|
|
oid: 1.3.6.1.4.1.232.6.2.15.3
|
|
type: gauge
|
|
help: This is the current Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.3
|
|
- name: cpqHePowerMeterPrevReading
|
|
oid: 1.3.6.1.4.1.232.6.2.15.4
|
|
type: gauge
|
|
help: This is the previous Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.4
|
|
- name: cpqHeHWBiosCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.16.1
|
|
type: gauge
|
|
help: This value indicates an error has been detected during Pre-OS Test (POST)
|
|
or during initial hardware initialization - 1.3.6.1.4.1.232.6.2.16.1
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeSysBackupBatteryCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.17.1
|
|
type: gauge
|
|
help: This value specifies the overall condition of the battery backup sub-system.
|
|
- 1.3.6.1.4.1.232.6.2.17.1
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeSysBatteryChassis
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.1
|
|
type: gauge
|
|
help: The system chassis number. - 1.3.6.1.4.1.232.6.2.17.2.1.1
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryIndex
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.2
|
|
type: gauge
|
|
help: The battery index number within this chassis. - 1.3.6.1.4.1.232.6.2.17.2.1.2
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryPresent
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.3
|
|
type: gauge
|
|
help: Indicates whether the backup battery is present in the chassis. - 1.3.6.1.4.1.232.6.2.17.2.1.3
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: absent
|
|
3: present
|
|
- name: cpqHeSysBatteryCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.4
|
|
type: gauge
|
|
help: The condition of the backup battery - 1.3.6.1.4.1.232.6.2.17.2.1.4
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeSysBatteryStatus
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.5
|
|
type: gauge
|
|
help: The status of the battery. - 1.3.6.1.4.1.232.6.2.17.2.1.5
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: noError
|
|
2: generalFailure
|
|
3: shutdownHighResistance
|
|
4: shutdownLowVoltage
|
|
5: shutdownShortCircuit
|
|
6: shutdownChargeTimeout
|
|
7: shutdownOverTemperature
|
|
8: shutdownDischargeMinVoltage
|
|
9: shutdownDischargeCurrent
|
|
10: shutdownLoadCountHigh
|
|
11: shutdownEnablePin
|
|
12: shutdownOverCurrent
|
|
13: shutdownPermanentFailure
|
|
14: shutdownBackupTimeExceeded
|
|
15: predictiveFailure
|
|
- name: cpqHeSysBatteryCapacityMaximum
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.6
|
|
type: gauge
|
|
help: The maximum capacity of the battery in watts. - 1.3.6.1.4.1.232.6.2.17.2.1.6
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryProductName
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.7
|
|
type: DisplayString
|
|
help: The battery product name. - 1.3.6.1.4.1.232.6.2.17.2.1.7
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryModel
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.8
|
|
type: DisplayString
|
|
help: The battery model name. - 1.3.6.1.4.1.232.6.2.17.2.1.8
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatterySerialNumber
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.9
|
|
type: DisplayString
|
|
help: The battery serial number. - 1.3.6.1.4.1.232.6.2.17.2.1.9
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatteryFirmwareRev
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.10
|
|
type: DisplayString
|
|
help: The battery firmware revision - 1.3.6.1.4.1.232.6.2.17.2.1.10
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeSysBatterySparePartNum
|
|
oid: 1.3.6.1.4.1.232.6.2.17.2.1.11
|
|
type: DisplayString
|
|
help: The battery part number or spare part number. - 1.3.6.1.4.1.232.6.2.17.2.1.11
|
|
indexes:
|
|
- labelname: cpqHeSysBatteryChassis
|
|
type: gauge
|
|
- labelname: cpqHeSysBatteryIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureChassis
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.1
|
|
type: gauge
|
|
help: The System Chassis number. - 1.3.6.1.4.1.232.6.2.6.8.1.1
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureIndex
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.2
|
|
type: gauge
|
|
help: A number that uniquely specifies this temperature sensor description. -
|
|
1.3.6.1.4.1.232.6.2.6.8.1.2
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureLocale
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.3
|
|
type: EnumAsInfo
|
|
help: This specifies the location of the temperature sensor present in the system.
|
|
- 1.3.6.1.4.1.232.6.2.6.8.1.3
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: unknown
|
|
3: system
|
|
4: systemBoard
|
|
5: ioBoard
|
|
6: cpu
|
|
7: memory
|
|
8: storage
|
|
9: removableMedia
|
|
10: powerSupply
|
|
11: ambient
|
|
12: chassis
|
|
13: bridgeCard
|
|
- name: cpqHeTemperatureCelsius
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.4
|
|
type: gauge
|
|
help: This is the current temperature sensor reading in degrees celsius - 1.3.6.1.4.1.232.6.2.6.8.1.4
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureThreshold
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.5
|
|
type: gauge
|
|
help: This is the shutdown threshold temperature sensor setting in degrees celsius
|
|
- 1.3.6.1.4.1.232.6.2.6.8.1.5
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeTemperatureCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.6
|
|
type: gauge
|
|
help: The Temperature sensor condition - 1.3.6.1.4.1.232.6.2.6.8.1.6
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeTemperatureThresholdType
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.7
|
|
type: gauge
|
|
help: This specifies the type of this instance of temperature sensor - 1.3.6.1.4.1.232.6.2.6.8.1.7
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
5: blowout
|
|
9: caution
|
|
15: critical
|
|
16: noreaction
|
|
- name: cpqHeTemperatureHwLocation
|
|
oid: 1.3.6.1.4.1.232.6.2.6.8.1.8
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the temperature sensor - 1.3.6.1.4.1.232.6.2.6.8.1.8
|
|
indexes:
|
|
- labelname: cpqHeTemperatureChassis
|
|
type: gauge
|
|
- labelname: cpqHeTemperatureIndex
|
|
type: gauge
|
|
- name: cpqHeFltTolPwrSupplyCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.9.1
|
|
type: gauge
|
|
help: This value specifies the overall condition of the fault tolerant power supply
|
|
sub-system. - 1.3.6.1.4.1.232.6.2.9.1
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeFltTolPwrSupplyStatus
|
|
oid: 1.3.6.1.4.1.232.6.2.9.2
|
|
type: gauge
|
|
help: This value specifies the status of the fault tolerant power supply. - 1.3.6.1.4.1.232.6.2.9.2
|
|
enum_values:
|
|
1: other
|
|
2: notSupported
|
|
3: notInstalled
|
|
4: installed
|
|
- name: cpqHeFltTolPowerSupplyChassis
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.1
|
|
type: gauge
|
|
help: The system chassis number. - 1.3.6.1.4.1.232.6.2.9.3.1.1
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyBay
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.2
|
|
type: gauge
|
|
help: The bay number to index within this chassis. - 1.3.6.1.4.1.232.6.2.9.3.1.2
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyPresent
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.3
|
|
type: gauge
|
|
help: Indicates whether the power supply is present in the chassis. - 1.3.6.1.4.1.232.6.2.9.3.1.3
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: absent
|
|
3: present
|
|
- name: cpqHeFltTolPowerSupplyCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.4
|
|
type: gauge
|
|
help: The condition of the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.4
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: degraded
|
|
4: failed
|
|
- name: cpqHeFltTolPowerSupplyStatus
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.5
|
|
type: gauge
|
|
help: The status of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.5
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: noError
|
|
2: generalFailure
|
|
3: bistFailure
|
|
4: fanFailure
|
|
5: tempFailure
|
|
6: interlockOpen
|
|
7: epromFailed
|
|
8: vrefFailed
|
|
9: dacFailed
|
|
10: ramTestFailed
|
|
11: voltageChannelFailed
|
|
12: orringdiodeFailed
|
|
13: brownOut
|
|
14: giveupOnStartup
|
|
15: nvramInvalid
|
|
16: calibrationTableInvalid
|
|
17: noPowerInput
|
|
- name: cpqHeFltTolPowerSupplyMainVoltage
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.6
|
|
type: gauge
|
|
help: The input main voltage of the power supply in volts. - 1.3.6.1.4.1.232.6.2.9.3.1.6
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyCapacityUsed
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.7
|
|
type: gauge
|
|
help: The currently used capacity of the power supply in watts. - 1.3.6.1.4.1.232.6.2.9.3.1.7
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyCapacityMaximum
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.8
|
|
type: gauge
|
|
help: The maximum capacity of the power supply in watts. - 1.3.6.1.4.1.232.6.2.9.3.1.8
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyRedundant
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.9
|
|
type: gauge
|
|
help: The redundancy state of the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.9
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: notRedundant
|
|
3: redundant
|
|
- name: cpqHeFltTolPowerSupplyModel
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.10
|
|
type: DisplayString
|
|
help: The power supply model name. - 1.3.6.1.4.1.232.6.2.9.3.1.10
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplySerialNumber
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.11
|
|
type: DisplayString
|
|
help: The power supply serial number. - 1.3.6.1.4.1.232.6.2.9.3.1.11
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyAutoRev
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.12
|
|
type: OctetString
|
|
help: The power supply auto revision number. - 1.3.6.1.4.1.232.6.2.9.3.1.12
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyHotPlug
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.13
|
|
type: gauge
|
|
help: This indicates if the power supply is capable of being removed and/or inserted
|
|
while the system is in an operational state - 1.3.6.1.4.1.232.6.2.9.3.1.13
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: other
|
|
2: nonHotPluggable
|
|
3: hotPluggable
|
|
- name: cpqHeFltTolPowerSupplyFirmwareRev
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.14
|
|
type: DisplayString
|
|
help: The power supply firmware revision - 1.3.6.1.4.1.232.6.2.9.3.1.14
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyHwLocation
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.15
|
|
type: DisplayString
|
|
help: A text description of the hardware location, on complex multi SBB hardware
|
|
only, for the power supply - 1.3.6.1.4.1.232.6.2.9.3.1.15
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplySparePartNum
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.16
|
|
type: DisplayString
|
|
help: The power supply part number or spare part number. - 1.3.6.1.4.1.232.6.2.9.3.1.16
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyRedundantPartner
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.17
|
|
type: gauge
|
|
help: This specifies the index of the redundant partner - 1.3.6.1.4.1.232.6.2.9.3.1.17
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
- name: cpqHeFltTolPowerSupplyErrorCondition
|
|
oid: 1.3.6.1.4.1.232.6.2.9.3.1.18
|
|
type: gauge
|
|
help: The Error condition of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.18
|
|
indexes:
|
|
- labelname: cpqHeFltTolPowerSupplyChassis
|
|
type: gauge
|
|
- labelname: cpqHeFltTolPowerSupplyBay
|
|
type: gauge
|
|
enum_values:
|
|
1: noError
|
|
2: generalFailure
|
|
3: overvoltage
|
|
4: overcurrent
|
|
5: overtemperature
|
|
6: powerinputloss
|
|
7: fanfailure
|
|
8: vinhighwarning
|
|
9: vinlowwarning
|
|
10: vouthighwarning
|
|
11: voutlowwarning
|
|
12: inlettemphighwarning
|
|
13: iinternaltemphighwarning
|
|
14: vauxhighwarning
|
|
15: vauxlowwarning
|
|
16: powersupplymismatch
|
|
17: goodinstandby
|
|
- name: cpqSm2CntlrRomDate
|
|
oid: 1.3.6.1.4.1.232.9.2.2.1
|
|
type: DisplayString
|
|
help: Remote Insight/ Integrated Lights-Out ROM Date - 1.3.6.1.4.1.232.9.2.2.1
|
|
- name: cpqSm2CntlrRomRevision
|
|
oid: 1.3.6.1.4.1.232.9.2.2.2
|
|
type: DisplayString
|
|
help: Remote Insight/ Integrated Lights-Out ROM Revision - 1.3.6.1.4.1.232.9.2.2.2
|
|
- name: cpqSm2CntlrVideoStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.3
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Video Hardware Status - 1.3.6.1.4.1.232.9.2.2.3
|
|
enum_values:
|
|
1: other
|
|
2: enabled
|
|
3: disabled
|
|
- name: cpqSm2CntlrBatteryEnabled
|
|
oid: 1.3.6.1.4.1.232.9.2.2.4
|
|
type: gauge
|
|
help: Remote Insight Battery Enabled - 1.3.6.1.4.1.232.9.2.2.4
|
|
enum_values:
|
|
1: other
|
|
2: enabled
|
|
3: disabled
|
|
4: noBattery
|
|
- name: cpqSm2CntlrBatteryStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.5
|
|
type: gauge
|
|
help: Remote Insight Battery Status - 1.3.6.1.4.1.232.9.2.2.5
|
|
enum_values:
|
|
1: other
|
|
2: batteryOk
|
|
3: batteryFailed
|
|
4: batteryDisconnected
|
|
- name: cpqSm2CntlrBatteryPercentCharged
|
|
oid: 1.3.6.1.4.1.232.9.2.2.6
|
|
type: gauge
|
|
help: Remote Insight Battery Percent Charged - 1.3.6.1.4.1.232.9.2.2.6
|
|
- name: cpqSm2CntlrAlertStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.7
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Alerting Status - 1.3.6.1.4.1.232.9.2.2.7
|
|
enum_values:
|
|
1: other
|
|
2: enabled
|
|
3: disabled
|
|
- name: cpqSm2CntlrPendingAlerts
|
|
oid: 1.3.6.1.4.1.232.9.2.2.8
|
|
type: gauge
|
|
help: Pending Remote Insight/ Integrated Lights-Out alerts - 1.3.6.1.4.1.232.9.2.2.8
|
|
enum_values:
|
|
1: other
|
|
2: noAlertsPending
|
|
3: alertsPending
|
|
4: clearPendingAlerts
|
|
- name: cpqSm2CntlrSelfTestErrors
|
|
oid: 1.3.6.1.4.1.232.9.2.2.9
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Self Test Errors - 1.3.6.1.4.1.232.9.2.2.9
|
|
- name: cpqSm2CntlrAgentLocation
|
|
oid: 1.3.6.1.4.1.232.9.2.2.10
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Agent Location - 1.3.6.1.4.1.232.9.2.2.10
|
|
enum_values:
|
|
1: hostOsAgent
|
|
2: firmwareAgent
|
|
3: remoteInsightPciFirmwareAgent
|
|
4: enclosureFirmwareAgent
|
|
- name: cpqSm2CntlrLastDataUpdate
|
|
oid: 1.3.6.1.4.1.232.9.2.2.11
|
|
type: OctetString
|
|
help: The date and time that the Remote Insight/ Integrated Lights-Out offline
|
|
data was last updated - 1.3.6.1.4.1.232.9.2.2.11
|
|
- name: cpqSm2CntlrDataStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.12
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Host OS Data Status - 1.3.6.1.4.1.232.9.2.2.12
|
|
enum_values:
|
|
1: other
|
|
2: noData
|
|
3: onlineData
|
|
4: offlineData
|
|
- name: cpqSm2CntlrColdReboot
|
|
oid: 1.3.6.1.4.1.232.9.2.2.13
|
|
type: gauge
|
|
help: 'Remote Insight/ Integrated Lights-Out Server Cold Reboot The following
|
|
values are defined: notAvailable(1) Cold reboot of the system is not available
|
|
- 1.3.6.1.4.1.232.9.2.2.13'
|
|
enum_values:
|
|
1: notAvailable
|
|
2: available
|
|
3: doColdReboot
|
|
- name: cpqSm2CntlrBadLoginAttemptsThresh
|
|
oid: 1.3.6.1.4.1.232.9.2.2.14
|
|
type: gauge
|
|
help: Maximum Unauthorized Login Attempts Threshold - 1.3.6.1.4.1.232.9.2.2.14
|
|
- name: cpqSm2CntlrBoardSerialNumber
|
|
oid: 1.3.6.1.4.1.232.9.2.2.15
|
|
type: DisplayString
|
|
help: Remote Insight/ Integrated Lights-Out Serial Number - 1.3.6.1.4.1.232.9.2.2.15
|
|
- name: cpqSm2CntlrRemoteSessionStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.16
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Session Status - 1.3.6.1.4.1.232.9.2.2.16
|
|
enum_values:
|
|
1: other
|
|
2: active
|
|
3: inactive
|
|
- name: cpqSm2CntlrInterfaceStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.17
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Interface Status - 1.3.6.1.4.1.232.9.2.2.17
|
|
enum_values:
|
|
1: other
|
|
2: ok
|
|
3: notResponding
|
|
- name: cpqSm2CntlrSystemId
|
|
oid: 1.3.6.1.4.1.232.9.2.2.18
|
|
type: DisplayString
|
|
help: Remote Insight/ Integrated Lights-Out System ID - 1.3.6.1.4.1.232.9.2.2.18
|
|
- name: cpqSm2CntlrKeyboardCableStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.19
|
|
type: gauge
|
|
help: Remote Insight Keyboard Cable Status - 1.3.6.1.4.1.232.9.2.2.19
|
|
enum_values:
|
|
1: other
|
|
2: connected
|
|
3: disconnected
|
|
- name: cpqSm2ServerIpAddress
|
|
oid: 1.3.6.1.4.1.232.9.2.2.20
|
|
type: InetAddressIPv4
|
|
help: The IP address for this servers connection to the Remote Insight/ Integrated
|
|
Lights-Out - 1.3.6.1.4.1.232.9.2.2.20
|
|
- name: cpqSm2CntlrModel
|
|
oid: 1.3.6.1.4.1.232.9.2.2.21
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Model - 1.3.6.1.4.1.232.9.2.2.21
|
|
enum_values:
|
|
1: other
|
|
2: eisaRemoteInsightBoard
|
|
3: pciRemoteInsightBoard
|
|
4: pciLightsOutRemoteInsightBoard
|
|
5: pciIntegratedLightsOutRemoteInsight
|
|
6: pciLightsOutRemoteInsightBoardII
|
|
7: pciIntegratedLightsOutRemoteInsight2
|
|
8: pciLightsOut100series
|
|
9: pciIntegratedLightsOutRemoteInsight3
|
|
10: pciIntegratedLightsOutRemoteInsight4
|
|
11: pciIntegratedLightsOutRemoteInsight5
|
|
- name: cpqSm2CntlrSelfTestErrorMask
|
|
oid: 1.3.6.1.4.1.232.9.2.2.22
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Self Test Error Mask - 1.3.6.1.4.1.232.9.2.2.22
|
|
- name: cpqSm2CntlrMouseCableStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.23
|
|
type: gauge
|
|
help: Remote Insight Mouse Cable Status - 1.3.6.1.4.1.232.9.2.2.23
|
|
enum_values:
|
|
1: other
|
|
2: connected
|
|
3: disconnected
|
|
- name: cpqSm2CntlrVirtualPowerCableStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.24
|
|
type: gauge
|
|
help: Remote Insight Virtual Power Cable Status - 1.3.6.1.4.1.232.9.2.2.24
|
|
enum_values:
|
|
1: other
|
|
2: connected
|
|
3: disconnected
|
|
4: notApplicable
|
|
- name: cpqSm2CntlrExternalPowerCableStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.25
|
|
type: gauge
|
|
help: Remote Insight External Power Cable Status - 1.3.6.1.4.1.232.9.2.2.25
|
|
enum_values:
|
|
1: other
|
|
2: externallyConnected
|
|
3: disconnected
|
|
4: internallyConnected
|
|
5: externallyAndInternallyConnected
|
|
6: notApplicable
|
|
- name: cpqSm2CntlrHostGUID
|
|
oid: 1.3.6.1.4.1.232.9.2.2.26
|
|
type: OctetString
|
|
help: The globally unique identifier of this server - 1.3.6.1.4.1.232.9.2.2.26
|
|
- name: cpqSm2CntlriLOSecurityOverrideSwitchState
|
|
oid: 1.3.6.1.4.1.232.9.2.2.27
|
|
type: gauge
|
|
help: Integrated Lights-Out Security Override Switch State - 1.3.6.1.4.1.232.9.2.2.27
|
|
enum_values:
|
|
1: notSupported
|
|
2: set
|
|
3: notSet
|
|
- name: cpqSm2CntlrHardwareVer
|
|
oid: 1.3.6.1.4.1.232.9.2.2.28
|
|
type: gauge
|
|
help: Hardware Version of Remote Insight/ Integrated Lights-Out. - 1.3.6.1.4.1.232.9.2.2.28
|
|
- name: cpqSm2CntlrAction
|
|
oid: 1.3.6.1.4.1.232.9.2.2.29
|
|
type: gauge
|
|
help: Remote Insight/ Integrated Lights-Out Action Flags - 1.3.6.1.4.1.232.9.2.2.29
|
|
- name: cpqSm2CntlrLicenseActive
|
|
oid: 1.3.6.1.4.1.232.9.2.2.30
|
|
type: gauge
|
|
help: Remote Insight License State - 1.3.6.1.4.1.232.9.2.2.30
|
|
enum_values:
|
|
1: none
|
|
2: iloAdvanced
|
|
3: iloLight
|
|
4: iloAdvancedBlade
|
|
5: iloStandard
|
|
6: iloEssentials
|
|
7: iloScaleOut
|
|
8: iloAdvancedPremiumSecurity
|
|
- name: cpqSm2CntlrLicenseKey
|
|
oid: 1.3.6.1.4.1.232.9.2.2.31
|
|
type: DisplayString
|
|
help: iLO Active ASCII License key string - 1.3.6.1.4.1.232.9.2.2.31
|
|
- name: cpqSm2CntlrServerPowerState
|
|
oid: 1.3.6.1.4.1.232.9.2.2.32
|
|
type: gauge
|
|
help: The current power state for the server - 1.3.6.1.4.1.232.9.2.2.32
|
|
enum_values:
|
|
1: unknown
|
|
2: poweredOff
|
|
3: poweredOn
|
|
4: insufficientPowerOrPowerOnDenied
|
|
- name: cpqSm2CntlrSysAutoShutdownCause
|
|
oid: 1.3.6.1.4.1.232.9.2.2.33
|
|
type: gauge
|
|
help: Indicate the reason for triggering system auto shutdown or cancelling auto
|
|
shutdown. - 1.3.6.1.4.1.232.9.2.2.33
|
|
enum_values:
|
|
1: fanFailure
|
|
2: overheatCondition
|
|
3: vrmFailure
|
|
4: powerSupplyFailure
|
|
5: systemRunningOnBatteryBackupUnit
|
|
129: aborted
|
|
130: fanFailureAborted
|
|
131: overheatAborted
|
|
132: vrmFailureAborted
|
|
133: softPowerDown
|
|
134: softwareAutomaticServerRecovery
|
|
135: powerSupplyFailureAborted
|
|
- name: cpqSm2CntlrSecurityState
|
|
oid: 1.3.6.1.4.1.232.9.2.2.34
|
|
type: gauge
|
|
help: Indicate security state - 1.3.6.1.4.1.232.9.2.2.34
|
|
enum_values:
|
|
1: factory
|
|
2: wipe
|
|
3: production
|
|
4: highSecurity
|
|
5: fips
|
|
6: cnsa
|
|
- name: cpqSm2WDTimerType
|
|
oid: 1.3.6.1.4.1.232.9.2.2.35
|
|
type: gauge
|
|
help: Indicate the watchdog timer type. - 1.3.6.1.4.1.232.9.2.2.35
|
|
enum_values:
|
|
1: unknown
|
|
2: ipmi
|
|
- name: cpqSm2WDTimerTimeoutDetails
|
|
oid: 1.3.6.1.4.1.232.9.2.2.36
|
|
type: DisplayString
|
|
help: Indicate the watchdog timer timeout action and timer details. - 1.3.6.1.4.1.232.9.2.2.36
|
|
- name: cpqSm2CntlrOverallSecStatus
|
|
oid: 1.3.6.1.4.1.232.9.2.2.37
|
|
type: gauge
|
|
help: The field indicates the overall security status. - 1.3.6.1.4.1.232.9.2.2.37
|
|
enum_values:
|
|
1: Ok
|
|
2: Risk
|
|
3: Ignored
|